Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
Front Transplant ; 3: 1449407, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39176402

RESUMEN

Since the first liver transplant was performed over six decades ago, the landscape of liver transplantation in the US has seen dramatic evolution. Numerous advancements in perioperative and operative techniques have resulted in major improvements in graft and patient survival rates. Despite the increase in transplants performed over the years, the waitlist mortality rate continues to remain high. The obesity epidemic and the resultant metabolic sequelae continue to result in more marginal donors and challenging recipients. In this review, we aim to highlight the changing characteristics of liver transplant recipients and liver allograft donors. We focus on issues relevant in successfully transplanting a high model for end stage liver disease recipient. We provide insights into the current use of terms and definitions utilized to discuss marginal allografts, discuss the need to look into more consistent ways to describe these organs and propose two new concepts we coin as "Liver Allograft Variables" (LAV) and "Liver Allograft Composite Score" (LACS) for this. We discuss the development of spectrum of risk indexes as a dynamic tool to characterize an allograft in real time. We believe that this concept has the potential to optimize the way we allocate, utilize and transplant livers across the US.

2.
Tissue Eng Part A ; 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38832856

RESUMEN

Background: The persistent challenge of organ scarcity in liver transplantation leads to an escalating dependence on organs obtained from extended criteria donors (ECD). Normothermic machine perfusion (NMP) is used for improved preservation. Due to the mimicked in vivo conditions during normothermic machine perfusion, the liver is metabolically active, which allows quality assessment during perfusion. Bile seems to be of rising interest in clinical studies, as it is easily collectible for analysis. As there are currently no data on biliary bile acids during NMP, the primary objective of this study was to use our experimental rodent NMP model to assess changes in bile composition through organ damage during perfusion to inform clinical evaluation of donor organs during NMP. Methods: Thirty livers from male Sprague-Dawley rats in five groups underwent 6 h of NMP using either erythrocyte-supplemented DMEM or Steen solution, with or without 30 min of warm ischemia time (WIT). We conducted regular measurements of AST, ALT, LDH, and urea levels in the perfusate at 3-hour intervals. Bile samples were analyzed for biliary pH, LDH, and gamma glutamyltransferase, as well as biliary bile acids via mass spectrometry and UHPLC. Results: Compared with regular livers, liver injury parameters were significantly higher in our donation after circulatory death (DCD) model. Bile production was significantly reduced in livers exposed to WIT, and the bile showed a significantly more alkaline pH. This correlated with the concentration of total bile acids, which was significantly higher in livers experiencing WIT. However, regular livers produced a higher total amount of biliary bile acids during perfusion. Taurocholic acid and its metabolites were most prominent. Secondary bile acids were significantly reduced during perfusion due to the missing enterohepatic circulation. Conclusions: WIT-induced liver injury affects bile composition within our small-animal NMP model. We hypothesize this phenomenon to be attributed to the energy-driven nature of bile secretion, potentially explaining why DCD livers produce less, yet more concentrated, bile. Our results may inform clinical studies, in which biliary bile acids might have a potential as a quantifiable viability marker in human NMP liver transplantation studies.

4.
Am J Transplant ; 24(9): 1664-1674, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38508317

RESUMEN

The imbalance between organ supply and demand continues to limit the broader benefits of organ transplantation. Machine perfusion (MP) may increase the supply of donor livers by expanding the use of extended-criteria donors. Using the United Network for Organ Sharing/Organ Procurement and Transplantation Network and the Standard Transplant Analysis and Research dataset, we reviewed the effect of MP implementation on the behavior of transplant centers. We identified 15 high-utilizing MP centers that were matched to suitable controls based on volume and geographical proximity. We conducted a differences-in-differences analysis using linear regression to estimate the impact of MP adoption on the transplant centers' donor utilization. We found a significant increase in cold ischemia time and organs with donor warm ischemia time over 30 minutes (P < .05). After removing one outlier center, the analysis showed that these centers through MP accepted overall more donation after circulatory death donors, donation after circulatory death donors over 50 years old, donors with macrovesicular steatosis greater than 30% on liver biopsy, and donor warm ischemia time over 30 minutes (P < .05). MP has allowed centers to expand their use of extended-criteria donors beyond traditional cutoffs and to increase patient access to liver transplantation.


Asunto(s)
Trasplante de Hígado , Preservación de Órganos , Perfusión , Donantes de Tejidos , Obtención de Tejidos y Órganos , Humanos , Donantes de Tejidos/provisión & distribución , Preservación de Órganos/métodos , Masculino , Persona de Mediana Edad , Femenino , Adulto , Isquemia Tibia , Pronóstico
5.
JACC Heart Fail ; 12(3): 438-447, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38276933

RESUMEN

BACKGROUND: Extended criteria donor (ECD) hearts available with donation after brain death (DBD) are underutilized for transplantation due to limitations of cold storage. OBJECTIVES: This study evaluated use of an extracorporeal perfusion system on donor heart utilization and post-transplant outcomes in ECD DBD hearts. METHODS: In this prospective, single-arm, multicenter study, adult heart transplant recipients received ECD hearts using an extracorporeal perfusion system if hearts met study criteria. The primary outcome was a composite of 30-day survival and absence of severe primary graft dysfunction (PGD). Secondary outcomes were donor heart utilization rate, 30-day survival, and incidence of severe PGD. The safety outcome was the mean number of heart graft-related serious adverse events within 30 days. Additional outcomes included survival through 2 years benchmarked to concurrent nonrandomized control subjects. RESULTS: A total of 173 ECD DBD hearts were perfused; 150 (87%) were successfully transplanted; 23 (13%) did not meet study transplantation criteria. At 30 days, 92% of patients had survived and had no severe PGD. The 30-day survival was 97%, and the incidence of severe PGD was 6.7%. The mean number of heart graft-related serious adverse events within 30 days was 0.17 (95% CI: 0.11-0.23). Patient survival was 93%, 89%, and 86% at 6, 12, and 24 months, respectively, and was comparable with concurrent nonrandomized control subjects. CONCLUSIONS: Use of an extracorporeal perfusion system resulted in successfully transplanting 87% of donor hearts with excellent patient survival to 2 years post-transplant and low rates of severe PGD. The ability to safely use ECD DBD hearts could substantially increase the number of heart transplants and expand access to patients in need. (International EXPAND Heart Pivotal Trial [EXPANDHeart]; NCT02323321; Heart EXPAND Continued Access Protocol; NCT03835754).


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Adulto , Humanos , Supervivencia de Injerto , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/métodos , Preservación de Órganos/métodos , Estudios Prospectivos , Estudios Retrospectivos , Donantes de Tejidos
6.
World J Gastroenterol ; 29(41): 5630-5640, 2023 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-38077155

RESUMEN

BACKGROUND: There is no consensus on the usage of extended criteria donor (ECD) grafts in liver transplantation (LT) for acute-on-chronic liver failure (ACLF) patients. AIM: To summarize the experience of using ECD livers in ACLF-LT. METHODS: A retrospective cohort study was conducted, enrolling patients who underwent LT at the First Affiliated Hospital of Sun Yat-Sen University from January 2015 to November 2021. The patients were divided into ECD and non-ECD groups for analysis. RESULTS: A total of 145 recipients were enrolled in this study, of which ECD and non-ECD recipients accounted for 53.8% and 46.2%, respectively. Donation after cardiac death (DCD) recipients accounted for the minority compared with donation after brain death (DBD) recipients (16.6% vs 83.4%). Neither overall survival nor graft survival significantly differed between ECD and non-ECD and DCD and DBD recipients. ECD grafts were associated with a significantly higher incidence of early allograft dysfunction (EAD) than non-ECD grafts (67.9% vs 41.8%, P = 0.002). Postoperative outcomes between DCD and DBD recipients were comparable (P > 0.05). ECD graft (P = 0.009), anhepatic phase (P = 0.034) and recipient gamma glutamyltransferase (P = 0.016) were independent risk factors for EAD. Recipient preoperative number of extrahepatic organ failures > 2 (P = 0.015) and intraoperative blood loss (P = 0.000) were independent predictors of poor post-LT survival. CONCLUSION: Although related to a higher risk of EAD, ECD grafts can be safely used in ACLF-LT. The main factors affecting post-LT survival in ACLF patients are their own severe preoperative disease and intraoperative blood loss.


Asunto(s)
Insuficiencia Hepática Crónica Agudizada , Trasplante de Hígado , Obtención de Tejidos y Órganos , Humanos , Trasplante de Hígado/efectos adversos , Insuficiencia Hepática Crónica Agudizada/cirugía , Insuficiencia Hepática Crónica Agudizada/etiología , Estudios Retrospectivos , Pérdida de Sangre Quirúrgica , Selección de Donante , Donantes de Tejidos , Muerte Encefálica , Supervivencia de Injerto , Muerte
7.
Lancet Reg Health Am ; 28: 100633, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38058662

RESUMEN

Healthcare systems in Latin America are broadly heterogeneous, but all of them are burdened by a dramatic rise in liver disease. Some challenges that these countries face include an increase in patients requiring a transplant, insufficient rates of organ donation, delayed referral, and inequitable or suboptimal access to liver transplant programs and post-transplant care. This could be improved by expanding the donor pool through the implementation of education programs for citizens and referring physicians, as well as the inclusion of extended criteria donors, living donors and split liver transplantation. Addressing these shortcomings will require national shifts aimed at improving infrastructure, increasing awareness of organ donation, training medical personnel, and providing equitable access to care for all patients.

8.
Tissue Eng Part A ; 29(19-20): 518-528, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37498780

RESUMEN

Normothermic ex vivo liver machine perfusion (NEVLP) has been developed to address the increasing organ shortage in liver transplantation, through optimal preservation, assessment, and conditioning of grafts from extended criteria donors. There remains a need to establish simple and standardized animal models that simulate clinical NEVLP to test novel therapies. Liver grafts from 36 Sprague-Dawley rats were perfused for 6 h in a dual-vessel NEVLP system with a Dulbecco's modified Eagles medium-based perfusate supplemented with rat plasma and erythrocytes. Varying doses of the clinically used vasodilator epoprostenol, Kupffer cell inhibitor glycine, and a Steen™-based perfusate were assessed. Perfusion pressures and bile production were recorded, and perfusate was analyzed for transaminase secretion. Tissue samples were evaluated histologically, and levels of cytokines and 8-Isoprostane were measured. Increasing levels of epoprostenol and the addition of glycine resulted in a stepwise decrease of transaminase secretion and improved bile production. Steen further decreased transaminase release and interleukin 1 beta levels. Liver grafts perfused with the optimized Steen-based protocol exhibited lowest levels of oxidative stress and best-preserved liver integrity. In conclusion, epoprostenol seemed to ameliorate liver function and prevent cellular damage beyond its vasodilatory effect, with glycine acting synergistically. The anti-inflammatory and antioxidative properties of Steen further improved the outcome of perfusion. Our rodent NEVLP system may be used to rapidly test new agents for the pharmacologic conditioning of livers and help translate findings from bench-to-bedside.

9.
Transpl Int ; 36: 11071, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37125386

RESUMEN

Donor shortages have led transplant centers to extend their criteria for lung donors. Accepting lung donors ≥70 years of age has previously shown good short-term outcomes; however, no mid- and long-term outcome data on these extended criteria donors has been published to date. In this study, all patients who underwent lung transplantation between 06/2010 and 12/2019 were included in the analysis, and the outcomes were compared between patients receiving organs from donors <70 years of age and patients transplanted with lungs from donors ≥70 years of age. Among the 1,168 lung-transplanted patients, 62 patients received lungs from donors ≥70 years of age. The recipient age of those receiving older organs was significantly higher, and they were more likely to suffer from obstructive lung disease. Older donors were exposed to significantly shorter periods of mechanical ventilation prior to donation, had higher Horowitz indices, and were less likely to have smoked. The postoperative time on mechanical ventilation, time on ICU, and total hospital stay were comparable. The overall survival as well as CLAD-free survival showed no differences between both groups in the follow-up period. Utilization of lungs from donors ≥70 years of age leads to excellent mid- and long-term results that are similar to organs from younger donors when the organs from older donors are carefully preselected.


Asunto(s)
Trasplante de Pulmón , Pulmón , Humanos , Resultado del Tratamiento , Factores de Edad , Donantes de Tejidos , Estudios Retrospectivos
10.
Clin Gastroenterol Hepatol ; 21(8): 2150-2166, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37084928

RESUMEN

Liver transplantation offers live-saving therapy for patients with complications of cirrhosis and stage T2 hepatocellular carcinoma. The demand for organs far outstrips the supply, and innovations aimed at increasing the number of usable deceased donors as well as alternative donor sources are a major focus. The etiologies of cirrhosis are shifting over time, with more need for transplantation among patients with alcohol-associated liver disease and nonalcoholic/metabolic fatty liver disease and less for viral hepatitis, although hepatitis B remains an important indication for transplant in countries with high endemicity. The rise in transplantation for alcohol-associated liver disease and nonalcoholic/metabolic fatty liver disease has brought attention to how patients are selected for transplantation and the strategies needed to prevent recurrent disease. In this review, we present a status report on the most pressing topics in liver transplantation and future challenges.


Asunto(s)
Carcinoma Hepatocelular , Enfermedad Hepática en Estado Terminal , Hepatopatías Alcohólicas , Neoplasias Hepáticas , Trasplante de Hígado , Enfermedad del Hígado Graso no Alcohólico , Humanos , Enfermedad Hepática en Estado Terminal/patología , Carcinoma Hepatocelular/cirugía , Carcinoma Hepatocelular/complicaciones , Cirrosis Hepática/complicaciones , Hepatopatías Alcohólicas/complicaciones , Fibrosis , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/complicaciones
11.
Int Urol Nephrol ; 55(10): 2611-2619, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36940004

RESUMEN

BACKGROUND: Diabetic donors are recognized as a reliable source of organs, although the discard rate of kidneys is still high. Few data are available on the histological evolution of these organs especially on kidneys transplanted into non-diabetic patients who remain euglycemic. METHODS: We describe the histological evolution of ten kidney biopsies performed on non-diabetic recipients of diabetic donors. RESULTS: Mean donor age was 69 ± 7 years, 60% were males. Two donors were treated with insulin, eight with oral antidiabetic drugs. Mean recipient age was 59.9 ± 7 years, 70% were males. The pre-existing diabetic lesions identified in the pre-implantation biopsies, encompassed all histological classes, and were associated with mild IF/TA and vascular damages. The median follow-up was 59.5 [IQR 32.5-99.0] months; at follow-up, 40% of cases did not change histologic classification, two patients with class IIb downgraded to IIa or I and one with class III downgraded to IIb. Conversely, three cases showed a worsening, from class 0 to I, I to IIb or from IIa to IIb. We also observed a moderate evolution of IF/TA and vascular damages. At follow-up visit, estimated GFR was stable (50.7 mL/min vs. 54.8 at baseline) and proteinuria was mild (51.1 ± 78.6 mg/day). CONCLUSIONS: Kidneys from diabetic donors show variable evolution of the histologic features of diabetic nephropathy after transplant. This variability may be associated to recipients characteristics such as euglycemic milieu, in case of improvement, or obesity and hypertension, in case of worsening of histologic lesions.


Asunto(s)
Diabetes Mellitus , Nefropatías Diabéticas , Trasplante de Riñón , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Trasplante de Riñón/efectos adversos , Riñón/patología , Donantes de Tejidos , Nefropatías Diabéticas/patología , Nefrectomía , Supervivencia de Injerto
13.
ANZ J Surg ; 93(4): 918-925, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36708059

RESUMEN

BACKGROUND: We analysed the impact of perceived liver donor quality on transplant recipient outcomes. METHODS: this prospective cohort study included all deceased liver donors during 2008-2018 in the Swiss Transplant Cohort Study. Perceived low-quality liver donors were defined when refused for ≥5 top listed recipients or for all recipients in at least one centre before being transplanted. The effect of liver donor quality on relisting or recipient death at 1 week and 1 year after transplantation was analysed using Kaplan-Meier and Cox proportional hazard models. A 1:3 matching was also performed using a recipient score. RESULTS: Of 973 liver donors, 187 (19.2%) had perceived poor-quality. Males, obesity, donation after circulatory death and alanine aminotransferase values were significantly associated with perceived poor-quality, with no significant effect of the perceived quality on re-listing or death within the first week and first year post-transplant [(aHR) = 1.45, 95% CI: (0.6, 3.5), P = 0.41 and aHR = 1.52 (95% CI 0.98-2.35), P = 0.06], adjusting by recipient age and gender, obesity, diabetes, prior liver transplantation and model for end-stage liver disease (MELD) score. At 1 year, prior liver transplantation and higher MELD score associated with higher risk of re-listing or death. CONCLUSION: Comparable post-transplant outcomes with different perceived quality liver donors stresses the need to improve donor selection in liver transplantation.


Asunto(s)
Enfermedad Hepática en Estado Terminal , Trasplante de Hígado , Obtención de Tejidos y Órganos , Masculino , Humanos , Enfermedad Hepática en Estado Terminal/cirugía , Estudios de Cohortes , Donadores Vivos , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Obesidad , Supervivencia de Injerto , Estudios Retrospectivos
14.
Tissue Eng Part B Rev ; 29(1): 10-27, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35848526

RESUMEN

The most common preservation technique for liver grafts is static cold storage. Due to the organ shortage for liver transplantation (LT), extended criteria donor (ECD) allografts are increasingly used-despite the higher risk of inferior outcome after transplantation. Ex vivo liver machine perfusion (MP) has been developed to improve the outcome of transplantation, especially with ECD grafts, and is currently under evaluation in clinical trials. We performed a literature search on PubMed and ISI Web of Science to assemble an overview of rodent and porcine animal models of ex vivo liver MP for transplantation, which is essential for the present and future development of clinical liver MP. Hypothermic, subnormothermic, and normothermic MP systems have been successfully used for rat and pig LT. In comparison with hypothermic systems, normothermic perfusion often incorporates a dialysis unit. Moreover, it enables metabolic assessment of liver grafts. Allografts experiencing warm ischemic time have a superior survival rate after MP compared with cold storage alone, irrespective of the temperature used for perfusion. Furthermore, ex vivo MP improves the outcome of regular and ECD liver grafts in animal models. Small and large animal models of ex vivo liver MP are available to foster the further development of this new technology. Impact Statement Ex vivo machine perfusion is an important part of current research in the field of liver transplantation. While evidence for improve storage is constantly rising, the development of future applications such as quality assessment and therapeutic interventions necessitates robust animal models. This review is intended to provide an overview of this technology in common large and small animal models and to give an outlook on future applications. Moreover, we describe developmental steps that can be followed by others, and which can help to decrease the number of animals used for experiments based on the replace, reduce, refine concept.


Asunto(s)
Trasplante de Hígado , Preservación de Órganos , Animales , Porcinos , Ratas , Preservación de Órganos/métodos , Hígado , Trasplante de Hígado/métodos , Perfusión/métodos , Modelos Animales
15.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1027568

RESUMEN

Expanded standard donor liver is an important source of liver donors for liver transplantation. Because expanded standard donor liver is more likely to cause ischemia-reperfusion injury and is inferior in quality to standard donor liver, machine perfusion is more suitable for the preservation of expanded standard donor liver than cold preservation. Subnormothermic machine perfusion can not only avoid the impact of cold injury on donor organs, but also effectively reduce ischemia reperfusion injury. This article will review the research progress of subnormothermic machine perfusion of the liver in order to provide a clinical reference.

16.
Front Transplant ; 2: 1132673, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38993877

RESUMEN

Introduction: The gap between available donor grafts and patients on the waiting lists is constantly growing. This leads to an increased utilization of high-risk and therefore more vulnerable kidney grafts. The use of high-risk organs requires further optimization of machine preservation and assessment strategies before transplantation. Hypothermic machine perfusion (HMP) is the standard of care for kidneys originating from donation after circulatory death (DCD), whereas the evidence of HMP with additional oxygen (HOPE) is still very limited. Furthermore, an objective quality assessment of HMP-perfused kidneys is lacking. Recently, the release of mitochondria derived fragments, i.e., flavin mononucleotide (FMN) of complex I during machine liver perfusion was shown to be predictive for liver graft function before implantation. Therefore, the aim of this study was to evaluate, if FMN is useful also for assessment of kidney injury before use. Methods: A porcine perfusion model was used to investigate the feasibility of assessment of kidney grafts during hypothermic oxygenated perfusion (HOPE) with either 0, 30 or 60 minutes of warm ischemia. The model with warm ischemia times (WIT) of 30 min and 60 min, was used to mimic a clinically relevant scenario. A group with no warm ischemia time (0' WIT) served as control group. The groups underwent minimal static cold storage (SCS) of 2 h followed by 2 h of end-ischemic HOPE with repeated real-time FMN measurements. In a further step, these values were related to the release of damage-associated molecular patterns (DAMPs) and to the functionality of the respiratory chain, represented by the capacity of ATP production. Results: We demonstrate, first, feasibility of perfusate FMN measurements in perfused kidneys, and secondly its correlation with donor warm ischemia time. Accordingly, FMN measurement showed significantly higher release in the 60-minute WIT group (n = 4) compared to the 30-minute WIT (n = 4) and the control group (n = 4). FMN release correlated also with DAMP signaling, such as the release of 8-OHdG and HMGB1. Finally, ATP replenishment proved to be best in control kidneys, followed by kidneys with 30 min and then by kidneys with 60 min of WIT. Discussion: This study demonstrates the feasibility of FMN measurement in kidneys during HOPE. In addition, we show a correlation between FMN quantification and pre-existing kidney graft injury. Based on this, real-time FMN measurement during HOPE may be an objective assessment tool to accept high-risk kidneys for transplantation while minimizing post-transplant dysfunction, moving away from former "gut feeling" towards objective criteria in accepting marginal kidney grafts for transplantation. Graft evaluation based on these results may close the gap between available grafts and patients on the waiting lists by increasing utilization rates without significant impact for the recipients.

18.
Transpl Int ; 35: 10712, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36338535

RESUMEN

In the era of organ machine perfusion, experimental models to optimize reconditioning of (marginal) liver grafts are needed. Although the relevance of cytokine signatures in liver transplantation has been analyzed previously, the significance of molecular monitoring during normothermic machine perfusion (NMP) remains elusive. Therefore, we developed a porcine model of cold ischemic liver graft injury after prolonged static cold storage (SCS) and subsequent NMP: Livers obtained from ten minipigs underwent NMP for 6 h directly after procurement (control group) or after 20 h of SCS. Grafts after prolonged SCS showed significantly elevated AST, ALT, GLDH and GGT perfusate concentrations, and reduced lactate clearance. Bile analyses revealed reduced bile production, reduced bicarbonate and elevated glucose concentrations after prolonged SCS. Cytokine analyses of graft perfusate simultaneously demonstrated an increase of pro-inflammatory cytokines such as Interleukin-1α, Interleukin-2, and particularly Interleukin-18. The latter was the only significantly elevated cytokine compared to controls, peaking as early as 2 h after reperfusion (11,012 ng/ml vs. 1,493 ng/ml; p = 0.029). Also, concentrations of High-Mobility-Group-Protein B1 were significantly elevated after 2 h of reperfusion (706.00 ng/ml vs. 148.20 ng/ml; p < 0.001) and showed positive correlations with AST (r 2 = 0.846) and GLDH (r 2 = 0.918) levels. Molecular analyses during reconditioning of liver grafts provide insights into the degree of inflammation and cell damage and could thereby facilitate future interventions during NMP reducing acute and chronic graft injury.


Asunto(s)
Trasplante de Hígado , Animales , Porcinos , Trasplante de Hígado/efectos adversos , Preservación de Órganos , Interleucina-18 , Porcinos Enanos , Perfusión , Hígado
19.
Transpl Int ; 35: 10838, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36262115
20.
Kidney Int Rep ; 7(8): 1850-1865, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35967103

RESUMEN

Introduction: The role of procurement biopsies in deceased donor kidney evaluation is debated in light of uncertainty about the influence of biopsy findings on recipient outcomes. The literature is filled with conflicting and ambiguous findings typically derived from small studies focused on short-term outcomes or reliant on biopsies prepared by methods impractical in the time-sensitive context of organ procurement. Methods: After manual data entry of DonorNet attachments from 4480 extended criteria donors (ECDs) recovered in the United States from 2008 to 2012, we applied causal inference methods in a Cox regression framework to estimate independent effects of glomerulosclerosis (GS), interstitial fibrosis, and vascular changes on long-term kidney graft survival. Kidney discard rates from 2018 to 2019 were evaluated to characterize contemporary kidney utilization patterns. Results: Effects of interstitial fibrosis and vascular changes were largely attenuated after adjusting for potentially confounding donor and recipient variables, although conclusions are less certain for severe levels due to smaller sample sizes. By contrast, significant effects of GS (>10% vs. 0%-5%) persisted even after adjustment (all-cause, hazard ratio [HR] 1.18; 95% CI 1.06, 1.28; death-censored, HR 1.28; 95% CI 1.08, 1.46) but plateaued beyond 10%. By contrast, kidney discard rates increased precipitously as GS rose >10%. Conclusion: Despite being obtained under less than ideal conditions, estimated GS from a procurement biopsy is independently associated with long-term graft survival, above and beyond standard clinical parameters, in ECD transplants. However, the disproportionately high likelihood of discard for kidneys with GS >10% is unjustified. The outsized effect of GS on kidney utilization should be tempered and commensurate with its effect on outcomes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA