Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Hazard Mater ; 476: 135136, 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39018597

RESUMEN

This study investigates the effects of chlorine dioxide (ClO2) disinfection on the community structure, regrowth potential, and metabolic product secretion of disinfection-residual bacteria (DRB) in secondary effluent (SE), denitrification filter effluent (DFE), and ultrafiltration effluent (UE). Results show that ClO2 effectively reduces bacteria in SE and UE, achieving log removal values exceeding 3 at 1 mg/L within 30 min. A salient positive correlation (R2 > 0.95) exists between changes in total fluorescence intensity and disinfection efficacy. Post-treatment, Acinetobacter abundance increased in SE, while Pseudomonas decreased in DFE and UE. At lower ClO2 concentrations, Staphylococcus, Mycobacterium, Aeromonas, and Lactobacillus increased in DFE, but decreased at higher concentrations. After storage, bacterial counts in disinfected samples exceeded those in the control group, surpassing 105 CFU/mL. Despite an initial decline, species richness and evenness partially recovered but remained lower than control levels. Culturing DRB for 72 h showed elevated extracellular polymeric substances (EPS) secretion, quantified as total organic carbon (TOC), ranging from 5 to 27 mg/L, with significantly higher EPS in the disinfection group. Parallel factor analysis with self-organizing maps (PARAFAC-SOM) effectively differentiated water sample types and EPS fluorescent substances, underscoring the potential of three-dimensional fluorescence as an indirect measure of ClO2 disinfection efficacy.


Asunto(s)
Bacterias , Compuestos de Cloro , Desinfectantes , Desinfección , Óxidos , Purificación del Agua , Compuestos de Cloro/farmacología , Óxidos/farmacología , Desinfección/métodos , Desinfectantes/farmacología , Bacterias/efectos de los fármacos , Bacterias/crecimiento & desarrollo , Bacterias/metabolismo , Purificación del Agua/métodos , Microbiología del Agua
2.
Environ Sci Technol ; 58(15): 6793-6803, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38574343

RESUMEN

Current disinfection processes pose an emerging environmental risk due to the ineffective removal of antibiotic-resistant bacteria, especially disinfection residual bacteria (DRB) carrying multidrug-resistant plasmids (MRPs). However, the characteristics of DRB-carried MRPs are poorly understood. In this study, qPCR analysis reveals that the total absolute abundance of four plasmids in postdisinfection effluent decreases by 1.15 log units, while their relative abundance increases by 0.11 copies/cell compared to investigated wastewater treatment plant (WWTP) influent. We obtain three distinctive DRB-carried MRPs (pWWTP-01-03) from postdisinfection effluent, each carrying 9-11 antibiotic-resistant genes (ARGs). pWWTP-01 contains all 11 ARGs within an ∼25 Kbp chimeric genomic island showing strong patterns of recombination with MRPs from foodborne outbreaks and hospitals. Antibiotic-, disinfectant-, and heavy-metal-resistant genes on the same plasmid underscore the potential roles of disinfectants and heavy metals in the coselection of ARGs. Additionally, pWWTP-02 harbors an adhesin-type virulence operon, implying risks of both antibiotic resistance and pathogenicity upon entering environments. Furthermore, some MRPs from DRB are capable of transferring and could confer selective advantages to recipients under environmentally relevant antibiotic pressure. Overall, this study advances our understanding of DRB-carried MRPs and highlights the imminent need to monitor and control wastewater MRPs for environmental security.


Asunto(s)
Desinfectantes , Purificación del Agua , Desinfección , Genes Bacterianos , Bacterias/genética , Antibacterianos/farmacología , Desinfectantes/farmacología , Plásmidos/genética
3.
Water Res ; 255: 121549, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38564891

RESUMEN

Conventional disinfection processes, such as chlorination and UV radiation, are ineffective in controling antibiotic-resistant bacteria, especially disinfection residual Enterobacteriaceae (DRE) encoding ß-lactamases, some of which have been classified as "critical priority pathogens" by the World Health Organization. However, few studies have focused on the transferability, phenotype, and genetic characteristics of DRE-derived plasmids encoding ß-lactamases, especially extended-spectrum ß-lactamases and carbapenemases. In this study, we isolated 10 typical DRE harboring plasmid-mediated blaNDM, blaCTX-M, or blaTEM in post-disinfection effluent from two wastewater treatment plants (WWTPs), with transfer frequency ranging from 1.69 × 10-6 to 3.02 × 10-5. According to genomic maps of plasmids, all blaNDM and blaTEM were cascaded with IS26, and blaCTX-M was adjacent to ISEcp1 or IS26, indicating the important role of these elements in the movement of ß-lactamase-encoding genes. The presence of intact class 1 integrons on pWTPN-01 and pWTPC-03 suggested the ability of these DRE-derived plasmids to integrate other exogenous antibiotic resistance genes (ARGs). The coexistence of antibiotic, disinfectant, and heavy metal resistance genes on the same plasmid (e.g., pWTPT-03) implied the facilitating role of disinfectants and heavy metals in the transmission of DRE-derived ARGs. Notably, two plasmid transconjugants exhibited no discernible competitive fitness cost, suggesting a heightened environmental persistence. Furthermore, enhanced virulence induced by ß-lactamase-encoding plasmids in their hosts was confirmed using Galleria mellonella infection models, which might be attributed to plasmid-mediated virulence genes. Overall, this study describes the landscape of ß-lactamase-encoding plasmids in DRE, and highlights the urgent need for advanced control of DRE to keep environmental and ecological security.

4.
Water Res ; 254: 121386, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38457942

RESUMEN

Traditional disinfection processes face significant challenges such as health and ecological risks associated with disinfection-residual-bacteria due to their single mechanism of action. Development of new disinfection processes with composite mechanisms is therefore urgently needed. In this study, we employed liquid ground-electrode dielectric barrier discharge (lgDBD) to achieve synergistic sterilization through electric field electroporation and reactive species oxidation. At a voltage of 12 kV, Pseudomonas fluorescens (ultraviolet and ozone-resistant) and Bacillus subtilis (chlorine-resistant) were completely inactivated within 8 and 6 min, respectively, surpassing a 7.0-log reduction. The lgDBD process showed good disinfection performance across a wide range of pH values and different practical water samples. Staining experiments suggest that cellular membrane damage contributes to this inactivation. In addition, we used a two-dimensional parallel streamer solver with kinetics code to fashion a representative model of the basic discharge unit, and discovered the presence of a persistent electric field during the discharge process with a peak value of 2.86 × 106 V/m. Plasma discharge generates excited state species such as O(1D) and N2(C3Πu), and further forms reactive oxygen and nitrogen species at the gas-liquid interface. The physical process, which is driven by electric field-induced cell membrane electroporation, synergizes with the bactericidal effects of reactive oxygen and nitrogen species to provide effective disinfection. Adopting the lgDBD process enhances sterilization efficiency and adaptability, underscoring its potential to revolutionize physicochemical synergistic disinfection practices.


Asunto(s)
Ozono , Purificación del Agua , Desinfección/métodos , Bacterias , Cloro , Nitrógeno , Purificación del Agua/métodos
5.
Sci Total Environ ; 896: 165199, 2023 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-37391159

RESUMEN

Ozone and chlorine are the most widely used disinfectants for water and wastewater disinfection. They play important role in microbial inactivation but could also pose a considerable selection effect on the microbial community of reclaimed water. Classical culture-based methods that rely on the assessment of conventional bacterial indicators (e.g., coliform bacteria) could hardly reflect the survival of disinfection residual bacteria (DRB) and hidden microbial risks in disinfected effluents. Hence, this study investigated the shifts of live bacterial community during ozone and chlorine disinfection in three reclaimed waters (i.e., two secondary effluents and one tertiary effluent), adopting Illumina Miseq sequencing technology in combination with a viability assay, propidium monoazide (PMA) pretreatment. Notably, statistical analyses of Wilcoxon rank-sum test confirmed the existance of distinct differences in bacterial community structure between samples with or without PMA pretreatment. On the phylum level, Proteobacteria commonly dominated in three undisinfected reclaimed waters, while ozone and chlorine disinfection posed varied effects on its relative abundance among different influents. On the genus level, ozone and chlorine disinfection significantly changed the bacterial composition and dominant species in reclaimed waters. Specifically, the typical DRB identified in ozone disinfected effluents were Pseudomonas, Nitrospira and Dechloromonas, while for chlorine disinfected effluents, Pseudomonas, Legionella, Clostridium, Mycobacterium and Romboutsia were recognized as typical DRB, which call for much attention. The Alpha and Beta diversity analysis results also suggested that different influent compositions greatly affected the bacterial community structure during disinfection processes. Since the experiments in present study were conducted in a short period and the dataset was relatively limited, prolonged experiment under different operational conditions are needed in future to illustrate the potential long-term effects of disinfection on the microbial community structure. The findings of this study could provide insights into microbial safety concern and control after disinfection for sustainable water reclamation and reuse.


Asunto(s)
Desinfectantes , Ozono , Purificación del Agua , Desinfección/métodos , Cloro/farmacología , Ozono/farmacología , Desinfectantes/farmacología , Bacterias , Agua , Cloruros , Purificación del Agua/métodos
6.
Sci Total Environ ; 844: 157079, 2022 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-35779720

RESUMEN

Membrane fouling is the Achilles' heel of the reverse osmosis (RO) system for high-quality reclaimed water production. Previous studies have found that after the significant selection effect of traditional disinfection, the remaining disinfection-residual bacteria (DRB) may possess more severe biofouling potentials. To provide more constructive advice for the prevention of biofouling, we compared the RO membrane fouling characteristics of DRB after using five commonly used disinfection methods (NaClO, NH2Cl, ClO2, UV, and O3) and two novel disinfection methods (K2FeO4 and the flow-through electrode system (FES)). Compared with the control group (undisinfected, 21.1 % flux drop), the UV-DRB biofilm aggravated biofouling of the RO membrane (23.4 % flux drop), while the FES, K2FeO4, and NH2Cl treatments showed less severe biofouling, with final flux drops of 6.9 %, 8.1 %, and 8.1 %, respectively. Adenosine triphosphate (ATP) was found to be a capable indicator for predicting the biofouling potential of DRB. Systematic analysis showed that the thickness and density of the DRB biofilms were most closely related to the different fouling degree of RO membranes. Moreover, the relative abundance of bacteria with higher extracellular polymeric substance (EPS) secretion levels, such as Pseudomonas and Sphingomonas, was found closely related with the biofouling degree of RO membranes.


Asunto(s)
Incrustaciones Biológicas , Purificación del Agua , Bacterias , Biopelículas , Incrustaciones Biológicas/prevención & control , Desinfección , Matriz Extracelular de Sustancias Poliméricas , Membranas Artificiales , Ósmosis , Purificación del Agua/métodos
7.
Water Res ; 204: 117606, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34500181

RESUMEN

The epidemic of COVID-19 has aroused people's particular attention to biosafety. A growing number of disinfection products have been consumed during this period. However, the flaw of disinfection has not received enough attention, especially in water treatment processes. While cutting down the quantity of microorganisms, disinfection processes exert a considerable selection effect on bacteria and thus reshape the microbial community structure to a great extent, causing the problem of disinfection-residual-bacteria (DRB). These systematic and profound changes could lead to the shift in regrowth potential, bio fouling potential, as well as antibiotic resistance level and might cause a series of potential risks. In this review, we collected and summarized the data from the literature in recent 10 years about the microbial community structure shifting of natural water or wastewater in full-scale treatment plants caused by disinfection. Based on these data, typical DRB with the most reporting frequency after disinfection by chlorine-containing disinfectants, ozone disinfection, and ultraviolet disinfection were identified and summarized, which were the bacteria with a relative abundance of over 5% in the residual bacteria community and the bacteria with an increasing rate of relative abundance over 100% after disinfection. Furthermore, the phylogenic relationship and potential risks of these typical DRB were also analyzed. Twelve out of fifteen typical DRB genera contain pathogenic strains, and many were reported of great secretion ability. Pseudomonas and Acinetobacter possess multiple disinfection resistance and could be considered as model bacteria in future studies of disinfection. We also discussed the growth, secretion, and antibiotic resistance characteristics of DRB, as well as possible control strategies. The DRB phenomenon is not limited to water treatment but also exists in the air and solid disinfection processes, which need more attention and more profound research, especially in the period of COVID-19.


Asunto(s)
COVID-19 , Microbiota , Bacterias , Desinfección , Humanos , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA