Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Arthroplasty ; 39(1): 193-197, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37343649

RESUMEN

BACKGROUND: Meta-diaphyseal fixation of straight, tapered, uncemented stems has been proven to be very reliable for total hip arthroplasty in 10 to 20 years of follow-up studies. The aim of the study was to evaluate whether the implant survival as well as radiological and functional outcome have changed in patients with a minimum follow-up of 30 years. METHODS: From a total of 210 patients, who received a straight, rectangular, tapered cementless stem and a threaded cup, there were 37 total hip arthroplasties (33 patients) still available for follow-up after a minimum of 30 years. Patients were examined clinically and radiographically, and revision surgeries were recorded. RESULTS: There was a low rate of revisions of the femoral stem with a survival probability of 0.92 (confidence interval 0.85 to 0.96) at 30 years. Survival probability of the acetabular component decreased drastically with 0.45 (confidence interval 0.30 to 0.59). Radiographic analysis of the stem revealed radiolucencies in 73% (n = 16), but only in the proximal/metaphyseal part and none of the stems were radiographically loose. CONCLUSION: In this minimum 30-year follow-up study, a straight rectangular cementless implant continues to provide excellent implant survival and high patient satisfaction. However, survival rates of the whole total hip replacement system were reduced by a high revision rate due to wear-related problems.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Estudios de Seguimiento , Prótesis de Cadera/efectos adversos , Resultado del Tratamiento , Diseño de Prótesis , Falla de Prótesis , Artroplastia de Reemplazo de Cadera/efectos adversos , Acetábulo , Reoperación
2.
J Shoulder Elb Arthroplast ; 7: 24715492231192055, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37547299

RESUMEN

Introduction: in the elderly patient population, where fracture comminution, osteoporotic fractures, and associated arthritis or rotator cuff pathologies dominate, metadiaphyseal proximal humeral fracture is a challenging subset of fractures to treat. This study reports on cementless long-stem reverse total shoulder arthroplasty (RTSA) as primary treatment of metadiaphyseal proximal humeral fractures in elderly patients. Materials & Methods: Between January 2018 and October 2021, 22 consecutive patients sustained proximal humerus fractures with metadiaphyseal extension and underwent surgery with cementless long-stem RTSA. Patients older than 60 years with minimum 1 year of clinical and radiographic follow-up were included. Patient demographics, range of motion, and patient reported outcomes [Visual Analog Scale (VAS) pain scale, Simple Shoulder Test (SST), Subjective Shoulder Value (SSV), and American Shoulder Elbow Surgeon (ASES) scores] were retrospectively collected. Postoperative X-rays were evaluated for fracture and tuberosity union. Results: There were 14 eligible patients with a median age of 71 years (range 61-91 years) and a median 13 months follow-up. At final follow-up, the median active elevation was 120° (range 80°-150°), external rotation was 40° (range 0°-50°), and internal rotation was 40° (range 0°-80°). Median VAS was 2 (range 0-8), SST was 71% (range 33%-92%), SSV was 78% (range 20-90%), and ASES was 73 (range 17-90). All patients exhibited radiographic union. There were five minor complications in three patients: postoperative neuropathy, tuberosity nonunion, scapula notching, and proximal humeral stress shielding. Conclusion: Cementless long-stem RTSA is a viable alternative to primary fracture fixation in the elderly patient population with metadiaphyseal proximal humerus fractures.

3.
J Arthroplasty ; 37(7S): S697-S702, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35307531

RESUMEN

BACKGROUND: Diaphyseal fixation remains the mainstay of revision THA. The stability of diaphyseal fixation can be quantified by the extent of contact between the stem and the endosteal cortex. This is highly affected by the morphology of the proximal femur. The purpose of this study was to examine factors affecting diaphyseal contact in the revision THA and to identify preoperative predictors of adequate fixation. METHODS: Three-dimensional femur models were created from CT scans of 33 Dorr B and C femora. The proximal 120 mm of the femur was omitted to mimic proximal bone deficiency. A tapered fluted stem (3 degrees, 150 mm) model was virtually implanted after reaming of the medullary canal. The contact length between stem and endosteal cortex was measured, in addition to other variables. The relationship between variables was evaluated using Spearman's correlation, and logistic regression analysis was used to identify predictors of the contact length (P < .05). RESULTS: The contact length varied widely between specimens (66.5 ± 16.6 mm, range: 21-98 mm). Contact increased with the depth of the isthmus below the lesser trochanter (range: 55-155 mm; r2 = 0.473, P = .005) and the distance between the isthmus and the distal edge of the damage zone (range: -9 to 96 mm; r2 = 0.508, P = .002). Stepwise regression identified the reaming length, distance between fracture and the isthmus, and isthmus diameter as independent predictors of contact length (r = 0.643). CONCLUSIONS: Contact is limited in specimens where the isthmus is more proximally located. In these cases, supplementary fixation using plating and/or longer, curved prosthesis may be considered.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Diseño de Prótesis , Reoperación/métodos , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA