Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Vet Immunol Immunopathol ; 276: 110826, 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39243492

RESUMEN

Mycoplasma hyopneumoniae (M. hyopneumoniae) is a significant porcine respiratory disease complex pathogen, prompting many swine farms and production systems to pursue M. hyopneumoniae elimination strategies. Antibody testing is cost-effective in demonstrating sustained freedom from M. hyopneumoniae, often replacing PCR testing on deep tracheal swabs. The process typically involves testing a subpopulation of the herd using an M. hyopneumoniae screening antibody ELISA, with non-negative results further assessed through confirmatory testing, such as PCR. Recently, a commercial (Biochek) fluorescent microsphere immunoassay (FMIA) for detecting M. hyopneumoniae antibodies has been introduced as an alternative to ELISA. Its performance was compared to three commercial ELISAs (Idexx, Hipra, and Biochek) using experimental serum samples from pigs inoculated with M. hyopneumoniae, M. hyorhinis, M. hyosynoviae, M. flocculare, or mock-inoculated with Friis medium. FMIA consistently detected M. hyopneumoniae at earlier time points than the ELISAs, although two false-positive results were encountered using the manufacturer's recommended cutoff. ROC analysis allowed for the evaluation of various cutoffs depending on testing objectives. Poisson regression of misclassification error counts detected no difference in the Biovet FMIA and Hipra ELISA but significantly fewer misclassification errors than Idexx and Biocheck ELISAs. This study showed FMIA as a suitable alternative to traditional ELISAs for screening purposes due to its superior antibody detection rate at early stages. Alternatively, adopting a more stringent cutoff to improve diagnostic specificity could position the FMIA as a viable confirmatory test option. Overall, FMIA is an optimal choice for M. hyopneumoniae antibody surveillance testing, offering versatility in testing strategies (e.g., triplex FMIA M. hyopneumoniae/PRRSV types 1 and 2) and contributing to improved diagnostic capabilities in porcine health management.

2.
Onderstepoort J Vet Res ; 91(1): e1-e7, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38949427

RESUMEN

Wild animals, sharing pathogens with domestic animals, play a crucial role in the epidemiology of infectious diseases. Sampling from wild animals poses significant challenges, yet it is vital for inclusion in disease surveillance and monitoring programmes. Often, mass surveillance involves serological screenings using enzyme-linked immunosorbent assay (ELISA) tests, typically validated only for domestic animals. This study assessed the diagnostic specificity of commercially available ELISA tests on 342 wild ruminant serum samples and 100 from wild boars. We evaluated three tests for foot-and-mouth disease: two for Peste des petits ruminants, two for Rift Valley fever and one for Capripox virus. Diagnostic specificity was calculated using the formula True Negative/(False Positive + True Negative). Cohen's kappa coefficient measured agreement between tests. Results showed high specificity and agreement across all tests. Specificity for foot-and-mouth disease (FMD) ranged from 93.89% for Prionics to 100% for IDEXX, with IDvet showing 99.6%. The highest agreement was between FMD IDvet and IDEXX at 97.1%. Rift Valley fever (RVF) tests, Ingezim and IDvet, achieved specificities of 100% and 98.83%, respectively. The optimal specificity was attained by retesting single reactors and inactivating the complement.Contribution: Commercially available ELISA kits are specific for foot-and-mouth disease and similar transboundary animal diseases and can be used for highly specific wild animal testing.


Asunto(s)
Animales Salvajes , Ensayo de Inmunoadsorción Enzimática , Sensibilidad y Especificidad , Animales , Ensayo de Inmunoadsorción Enzimática/veterinaria , Fiebre Aftosa/diagnóstico , Fiebre del Valle del Rift/diagnóstico , Fiebre del Valle del Rift/sangre , Sus scrofa , Rumiantes , Anticuerpos Antivirales/sangre
3.
J Allergy Clin Immunol Pract ; 12(8): 2144-2154.e11, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38734371

RESUMEN

BACKGROUND: Poppy seed (PS) can be a cause of severe allergic reactions, especially in individuals with concurrent allergy to tree nuts and other seeds, but diagnostic criteria and sensitization patterns are lacking. OBJECTIVE: To assess the role of PS extract and individual allergens in diagnosing PS allergy and their cross-reactivities with tree nuts and buckwheat. METHODS: Our retrospective study included 36 PS-sensitized patients; 10 with a positive and 26 with a negative oral food challenge (OFC). We identified individual PS allergens and compared the diagnostic performance of specific IgE (sIgE) to PS extract with its allergens. Cross-reactivities between PS and related allergens from other seeds were assessed by a competitive enzyme-linked immunosorbent assay. RESULTS: We identified 4 novel PS allergens: Pap s 1 (vicilin), Pap s 1 (27-424) (α-hairpinin), Pap s 2 (legumin), and Pap s 3 (small hydrophilic seed protein). A positive OFC correlated with higher PS-sIgE levels and elevated sIgE levels for the PS allergens, except for Pap s 3. PS and α-hairpinin-sIgE effectively differentiated allergic from tolerant patients, with area under the curve values of 0.95 and 0.94. PS-sIgE >10.00 kUA/L exhibited 90% sensitivity and 73% specificity, whereas α-hairpinin-sIgE >2.60 kUA/L showed 100% sensitivity and 77% specificity. PS vicilin and legumin highly cross-reacted with hazelnut and buckwheat homologs, whereas α-hairpinin-sIgE cross-reacted with the related almond allergen. CONCLUSIONS: This is the most extensive study on PS allergy to date. PS and α-hairpinin-sIgE are highly sensitive indicators of clinical reactivity to PS, whereas vicilin and legumin-sIgE contribute to concurrent sensitization to hazelnut and buckwheat.


Asunto(s)
Alérgenos , Reacciones Cruzadas , Inmunoglobulina E , Hipersensibilidad a la Nuez , Proteínas de Almacenamiento de Semillas , Semillas , Humanos , Inmunoglobulina E/sangre , Inmunoglobulina E/inmunología , Femenino , Masculino , Semillas/inmunología , Alérgenos/inmunología , Estudios Retrospectivos , Proteínas de Almacenamiento de Semillas/inmunología , Hipersensibilidad a la Nuez/diagnóstico , Hipersensibilidad a la Nuez/inmunología , Adulto , Antígenos de Plantas/inmunología , Fagopyrum/inmunología , Fagopyrum/efectos adversos , Adolescente , Nueces/inmunología , Nueces/efectos adversos , Niño , Proteínas de Plantas/inmunología , Persona de Mediana Edad , Leguminas/inmunología , Adulto Joven
4.
EBioMedicine ; 104: 105144, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38723553

RESUMEN

BACKGROUND: Two or more autoantibodies against either insulin (IAA), glutamic acid decarboxylase (GADA), islet antigen-2 (IA-2A) or zinc transporter 8 (ZnT8A) denote stage 1 (normoglycemia) or stage 2 (dysglycemia) type 1 diabetes prior to stage 3 type 1 diabetes. Automated multiplex Antibody Detection by Agglutination-PCR (ADAP) assays in two laboratories were compared to single plex radiobinding assays (RBA) to define threshold levels for diagnostic specificity and sensitivity. METHODS: IAA, GADA, IA-2A and ZnT8A were analysed in 1504 (54% females) population based controls (PBC), 456 (55% females) doctor's office controls (DOC) and 535 (41% females) blood donor controls (BDC) as well as in 2300 (48% females) patients newly diagnosed (1-10 years of age) with stage 3 type 1 diabetes. The thresholds for autoantibody positivity were computed in 100 10-fold cross-validations to separate patients from controls either by maximizing the χ2-statistics (chisq) or using the 98th percentile of specificity (Spec98). Mean and 95% CI for threshold, sensitivity and specificity are presented. FINDINGS: The ADAP ROC curves of the four autoantibodies showed comparable AUC in the two ADAP laboratories and were higher than RBA. Detection of two or more autoantibodies using chisq showed 0.97 (0.95, 0.99) sensitivity and 0.94 (0.91, 0.97) specificity in ADAP compared to 0.90 (0.88, 0.95) sensitivity and 0.97 (0.94, 0.98) specificity in RBA. Using Spec98, ADAP showed 0.92 (0.89, 0.95) sensitivity and 0.99 (0.98, 1.00) specificity compared to 0.89 (0.77, 0.86) sensitivity and 1.00 (0.99, 1.00) specificity in the RBA. The diagnostic sensitivity and specificity were higher in PBC compared to DOC and BDC. INTERPRETATION: ADAP was comparable in two laboratories, both comparable to or better than RBA, to define threshold levels for two or more autoantibodies to stage type 1 diabetes. FUNDING: Supported by The Leona M. and Harry B. Helmsley Charitable Trust (grant number 2009-04078), the Swedish Foundation for Strategic Research (Dnr IRC15-0067) and the Swedish Research Council, Strategic Research Area (Dnr 2009-1039). AL was supported by the DiaUnion collaborative study, co-financed by EU Interreg ÖKS, Capital Region of Denmark, Region Skåne and the Novo Nordisk Foundation.


Asunto(s)
Autoanticuerpos , Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/inmunología , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/sangre , Autoanticuerpos/sangre , Autoanticuerpos/inmunología , Femenino , Masculino , Niño , Preescolar , Lactante , Transportador 8 de Zinc/inmunología , Sensibilidad y Especificidad , Proteínas Tirosina Fosfatasas Clase 8 Similares a Receptores/inmunología , Glutamato Descarboxilasa/inmunología , Curva ROC , Tamizaje Masivo/métodos
5.
Prev Vet Med ; 222: 106079, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38056065

RESUMEN

The direct methods for diagnosis of bovine brucellosis have several limitations, therefore serological tests are the basis for the diagnosis of the disease. However, a meta-analysis estimating the diagnostic sensitivity (DSe) and diagnostic specificity (DSp) on the main tests used in bovine brucellosis control programs worldwide has not been performed. This systematic review and meta-analysis aimed to estimate the DSe, DSp and thereby accuracy of serological tests individually used in the diagnosis of bovine brucellosis. The databases CABI, Cochrane Library, PubMed/MEDLINE, SciELO, Scopus and Web of Science were used to select articles. The search resulted in 5308 studies, of which 71 were selected for systematic review using quality assessment tools and 65 studies were included in the meta-analysis. For the meta-analysis, 178 assays and 11 different serological tests were considered. To estimate DSe and DSp of the tests, studies were divided according to animal selection for the studies: (1) studies that carried out a random or consecutive selection of participants (noncasecontrol studies) and (2) all studies, including casecontrol studies. Considering only the non-case-control studies to estimate the DSe, the tests that exhibited the best and worst performance were the iELISA test (indirect enzyme immunoassay - bacterial suspension as antigen - BS) (96.5%, 95% CI: 94.1-97.9%) and 2ME (2- mercaptoethanol test) (85.0%, 95% CI: 79.6-89.1%), respectively; while for DSp, the FPA (fluorescence polarization assay) (99, 7%, 95% CI: 99.5-99.8%) and PCFIA tests (protein concentration fluorescence immunoassay) (78.5%, 95% CI: 70.0-85.1%) showed better and worse performance, respectively. Overall, our results showed an overestimation in the DSe and DSp of the eleven serological tests assessed when casecontrol studies were included in the meta-analysis, which is a concern considering its impacts on the time and costs associated with populational diagnosis of the diseases, since several of these tests are routinely used in the control and eradication programs of bovine brucellosis worldwide. Furthermore, the tests that exhibited the best DSe and DSp, iELISA (BS) and FPA, respectively, are relatively easy to perform and interpret and the test which showed the best overall accuracy was FPA.


Asunto(s)
Brucelosis Bovina , Brucelosis , Enfermedades de los Bovinos , Bovinos , Animales , Sensibilidad y Especificidad , Brucelosis Bovina/diagnóstico , Inmunoensayo de Polarización Fluorescente/métodos , Inmunoensayo de Polarización Fluorescente/veterinaria , Ensayo de Inmunoadsorción Enzimática/veterinaria , Ensayo de Inmunoadsorción Enzimática/métodos , Pruebas Serológicas/veterinaria , Brucelosis/diagnóstico , Brucelosis/veterinaria , Anticuerpos Antibacterianos
6.
Prev Vet Med ; 214: 105886, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36913890

RESUMEN

We present a new confidence interval for the prevalence of a disease for a situation when sensitivity and specificity of the diagnostic test are estimated from validation samples independent of the study sample. The new interval is based on profile likelihood and incorporates an adjustment improving the coverage probability. Its coverage probability and expected length were assessed by simulation and compared to two other methods for this problem, namely those by Lang and Reiczigel (2014) and Flor et al. (2020). Expected length of the new interval is less than that of the Lang and Reiczigel interval while its coverage is about the same. Comparison to the Flor interval resulted in similar expected length but higher coverage probabilities for the new interval. All in all, the new interval proved to be better than both its competitors.


Asunto(s)
Pruebas Diagnósticas de Rutina , Modelos Estadísticos , Animales , Funciones de Verosimilitud , Prevalencia , Intervalos de Confianza , Pruebas Diagnósticas de Rutina/veterinaria
7.
J Vet Diagn Invest ; 35(3): 236-245, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36782370

RESUMEN

We estimated the diagnostic sensitivity (DSe) and specificity (DSp) of an immunohistochemistry (IHC) protocol compared to the direct fluorescent antibody test (DFAT), which is the gold standard test for rabies diagnosis. We obtained brain samples from 199 domestic and wild animal cases (100 DFAT-negative, 99 DFAT-positive), by convenience sampling from 2 government-accredited rabies virus (RABV) testing laboratories in South Africa, between February 2015 and August 2017. Tissues that had been stored at 4-8°C for several days to weeks at the 2 accredited laboratories were formalin-fixed and paraffin-embedded. Nighty-eight cases tested IHC-positive using a polyclonal anti-RABV nucleoprotein antibody and a polymer detection system. The overall DSe and DSp for the RABV IHC test were 98% (95% CI: 93-100%) and 99% (95% CI: 95-100%), respectively. Domestic dogs accounted for 41 of 98 RABV IHC-positive cases, with the remainder in 4 domestic cats, 25 livestock, and 28 wildlife. Herpestidae species, including 7 meerkats and 9 other mongoose species, were the most frequently infected wild carnivores, followed by 11 jackals. Three cases in domestic dogs had discordant test results; 2 cases were IHC-/DFAT+ and 1 case was IHC+/DFAT-. Considering the implications of a false-negative rabies diagnosis, participating in regular inter-laboratory comparisons is vital, and a secondary or confirmatory method, such as IHC, should be performed on all submitted specimens, particularly negative cases with human contact history.


Asunto(s)
Enfermedades de los Gatos , Enfermedades de los Perros , Virus de la Rabia , Rabia , Humanos , Animales , Perros , Gatos , Animales Salvajes , Rabia/diagnóstico , Rabia/epidemiología , Rabia/veterinaria , Sudáfrica/epidemiología , Inmunohistoquímica , Sensibilidad y Especificidad , Enfermedades de los Perros/diagnóstico
8.
Am J Kidney Dis ; 81(2): 179-189, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36108889

RESUMEN

RATIONALE & OBJECTIVE: The occurrence and consequences of peritoneal dialysis (PD)-associated peritonitis limit its use in populations with kidney failure. Studies of large clinical populations may enhance our understanding of peritonitis. To facilitate these studies we developed an approach to measuring peritonitis rates using Medicare claims data to characterize peritonitis trends and identify its clinical risk factors. STUDY DESIGN: Retrospective cohort study of PD-associated peritonitis. SETTING & PARTICIPANTS: US Renal Data System standard analysis files were used for claims, eligibility, modality, and demographic information. The sample consisted of patients receiving PD treated at some time between 2013 and 2017 who were covered by Medicare fee-for-service (FFS) insurance with paid claims for dialysis or hospital services. EXPOSURES/PREDICTORS: Peritonitis risk was characterized by year, age, sex, race, ethnicity, vintage of kidney replacement therapy, cause of kidney failure, and prior peritonitis episodes. OUTCOME: The major outcome was peritonitis, identified using ICD-9 and ICD-10 diagnosis codes. Closely spaced peritonitis claims (30 days) were aggregated into 1 peritonitis episode. ANALYTICAL APPROACH: Patient-level risk factors for peritonitis were modeled using Poisson regression. RESULTS: We identified 70,271 peritonitis episodes from 396,289 peritonitis claims. Although various codes were used to record an episode of peritonitis, none was used predominantly. Peritonitis episodes were often identified by multiple aggregated claims, with the mean and median claims per episode being 5.6 and 2, respectively. We found 40% of episodes were exclusively outpatient, 9% exclusively inpatient, and 16% were exclusively based on codes that do not clearly distinguish peritonitis from catheter infections/inflammation ("catheter codes"). The overall peritonitis rate was 0.54 episodes per patient-year (EPPY). The rate was 0.45 EPPY after excluding catheter codes and 0.35 EPPY when limited to episodes that only included claims from nephrologists or dialysis providers. The peritonitis rate declined by 5%/year and varied by patient factors including age (lower rates at higher ages), race (Black > White>Asian), and prior peritonitis episodes (higher rate with each prior episode). LIMITATIONS: Coding heterogeneity indicates a lack of standardization. Episodes based exclusively on catheter codes could represent false positives. Peritonitis episodes were not validated against symptoms or microbiologic data. CONCLUSIONS: PD-associated peritonitis rates decline over time and were lower among older patients. A claims-based approach offers a promising framework for the study of PD-associated peritonitis.


Asunto(s)
Fallo Renal Crónico , Diálisis Peritoneal , Peritonitis , Humanos , Anciano , Estados Unidos/epidemiología , Estudios Retrospectivos , Fallo Renal Crónico/epidemiología , Fallo Renal Crónico/terapia , Fallo Renal Crónico/complicaciones , Medicare , Diálisis Peritoneal/efectos adversos , Factores de Riesgo , Peritonitis/epidemiología , Peritonitis/etiología , Peritonitis/tratamiento farmacológico
9.
Transbound Emerg Dis ; 69(5): e3024-e3035, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35810475

RESUMEN

Estimation of the diagnostic performance of serological tests often relies on another test assumed as a reference or on samples of known infection status, yet both are seldom available for emerging pathogens in wildlife. Longitudinal disease serological data can be analysed through multi-event capture-mark-recapture (MECMR) models accounting for the uncertainty in state assignment, allowing us to estimate epidemiological parameters such as incidence and mortality. We hypothesized that by estimating the uncertainty in state assignment, MECMR models estimate the diagnostic performance of serological tests for rabbit haemorrhagic disease virus (RHDV) and myxoma virus (MYXV). We evaluated this hypothesis on longitudinal serological data of three tests of RHDV and one test of MYXV in two populations of the European rabbit (Oryctolagus cuniculus algirus). First, we selected the optimal cut-off threshold for each test using finite mixture models, a reference method not relying on reference tests or samples. Second, we used MECMR models to compare the diagnostic sensitivity (Se) and specificity (Sp) of the three tests for RHDV. Third, we compared the estimates of diagnostic performance by MECMR and finite mixture models across a range of cut-off values. The MECMR models showed that the RHDV test employing GI.2 antigens (Se: 100%) outperformed two tests employing GI.1 antigens (Se: 21.7% ± 8.6% and 8.7% ± 5.9%). At their selected cut-offs (2.0 for RHDV GI.2 and 2.4 for MYXV), the estimates of Se and Sp were concordant between the MECMR and finite mixture models. Over the duration of the study (May 2018 to September 2020), the monthly survival of European rabbits seropositive for MYXV was significantly higher than that of seronegative rabbits (82.7% ± 4.9% versus 61.5% ± 12.7%) at the non-fenced site. We conclude that MECMR models can reliably estimate the diagnostic performance of serological tests for RHDV and MYXV in European rabbits. This conclusion could extend to other diagnostic tests and host-pathogen systems. Longitudinal disease surveillance data analysed through MECMR models allow the validation of diagnostic tests for emerging pathogens in novel host species while simultaneously estimating epidemiological parameters.


Asunto(s)
Infecciones por Caliciviridae , Virus de la Enfermedad Hemorrágica del Conejo , Myxoma virus , Mixoma , Animales , Infecciones por Caliciviridae/diagnóstico , Infecciones por Caliciviridae/epidemiología , Infecciones por Caliciviridae/veterinaria , Mixoma/veterinaria , Conejos , Pruebas Serológicas/veterinaria
10.
Prev Vet Med ; 205: 105694, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35751981

RESUMEN

The MilA ELISA has been identified as a highly effective diagnostic tool for the detection of Mycoplasma bovis specific antibodies and has been validated for serological use in previous studies. This study aimed to estimate the optimal cut-off and corresponding estimates of diagnostic sensitivity (DSe) and diagnostic specificity (DSp) of the MilA ELISA for testing bovine serum. Serum samples from 298 feedlot cattle from 14 feedlots across four Australian states were tested on entry into the feedlot and approximately 42 days later. The paired serum samples were tested with the MilA ELISA, BIO K302 (Bio-X Diagnostics, Belgium) and BIO K260 (Bio-X Diagnostics, Belgium). A cut-off of 135 AU was estimated to be optimal using Bayesian latent class analysis with three tests in multiple populations, accounting for conditional dependence between tests. At this cut-off, the DSe and DSp of the MilA ELISA were estimated to be 92.1 % (95 % highest probability density [HPD] interval: 87.4, 95.8) and 95.5 % (95 % HPD: 92.4, 97.8), respectively. The DSes of the BIO K260 and BIO K302 ELISAs were estimated to be 60.5 % (95 % HPD: 54.0, 66.9) and 44.6 % (95 % HPD: 38.7, 50.7), respectively. DSps were 95.6 % (95 % HPD: 92.9, 97.7) and 97.8 % (95 % HPD: 95.9, 99.0), respectively. Mycoplasma bovis seroprevalence was remarkably high at follow-up after 42 days on the feedlots. Overall, this study estimated a cut-off, DSe and DSp for the MilA ELISA with less dependence on prior information than previous analyses and demonstrated that the MilA ELISA has higher DSe than the BIO K260 and BIO K302 assays.


Asunto(s)
Enfermedades de los Bovinos , Mycoplasma bovis , Animales , Anticuerpos Antibacterianos , Australia , Teorema de Bayes , Bovinos , Enfermedades de los Bovinos/diagnóstico , Enfermedades de los Bovinos/epidemiología , Ensayo de Inmunoadsorción Enzimática/veterinaria , Análisis de Clases Latentes , Sensibilidad y Especificidad , Estudios Seroepidemiológicos
11.
Transbound Emerg Dis ; 69(5): e1951-e1958, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35316576

RESUMEN

Reverse transcription polymerase chain reaction (RT-PCR) is currently the standard diagnostic method to detect symptomatic and asymptomatic individuals infected with Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). However, RT-PCR results are not immediate and may falsely be negative before an infected individual sheds viral particles in the upper airways where swabs are collected. Infected individuals emit volatile organic compounds in their breath and sweat that are detectable by trained dogs. Here, we evaluate the diagnostic accuracy of dog detection against SARS-CoV-2 infection. Fifteen dogs previously trained at two centres in Australia were presented to axillary sweat specimens collected from known SARS-CoV-2 human cases (n = 100) and non-cases (n = 414). The true infection status of the cases and non-cases were confirmed based on RT-PCR results as well as clinical presentation. Across dogs, the overall diagnostic sensitivity (DSe) was 95.3% (95%CI: 93.1-97.6%) and diagnostic specificity (DSp) was 97.1% (95%CI: 90.7-100.0%). The DSp decreased significantly when non-case specimens were collected over 1 min rather than 20 min (p value = .004). The location of evaluation did not impact the detection performances. The accuracy of detection varied across dogs and experienced dogs revealed a marginally better DSp (p value = .016). The potential and limitations of this alternative detection tool are discussed.


Asunto(s)
COVID-19 , Animales , COVID-19/diagnóstico , Prueba de COVID-19 , Perros , Humanos , SARS-CoV-2 , Sensibilidad y Especificidad , Compuestos Orgánicos Volátiles
12.
Cancer Cytopathol ; 130(2): 96-109, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34478240

RESUMEN

Cytology effusions are often the only material available for diagnosing malignant pleural mesothelioma (MPM). However, the cytomorphological features alone are not always diagnostic, and cytology samples preclude an assessment for pleural tissue invasion. Accordingly, immunohistochemical, soluble, and molecular biomarkers have been developed. The aim of this study is to provide quantitative evidence regarding the diagnostic performance of novel biomarkers. To that end, a systematic literature review was performed of articles dealing with a loss of BRCA1-associated protein 1 (BAP1), methylthioadenosine (MTAP), 5-hydroxymethylcitosine (5-hmC), glucose transporter 1 (GLUT1), insulin like-growth factor II messenger RNA-binding protein 3 (IMP3), enhanced zeste homologue 2 (EZH2) staining, cyclin-dependent kinase inhibitor 2A (CDKN2A) homozygous deletion (HD) testing, soluble mesothelin, and microRNA quantification in cytological samples for the diagnosis of MPM versus reactive atypical mesothelial cells. Sensitivity and specificity were extracted, and a meta-analysis was performed. The quality of the studies was assessed with Quality Assessment of Diagnostic Accuracy Studies 2, and the quality of the evidence was evaluated with the Grading of Recommendations Assessment, Development, and Evaluation approach. Seventy-one studies were included. BAP1 loss showed a sensitivity of 0.65 (confidence interval [CI], 0.59-0.71) and a specificity of 0.99 (CI, 0.93-1.00). MTAP loss and p16 HD showed 100% specificity with sensitivities of 0.47 (CI, 0.38-0.57) and 0.62 (CI, 0.53-0.71), respectively. BAP1 loss and CDKN2A HD combined showed maximal specificity and a sensitivity of 0.83 (CI, 0.78-0.89). GLUT1 and IMP3 showed sensitivities of 0.82 (CI, 0.70-0.90) and 0.65 (CI, 0.41-0.90), respectively, with comparable specificity. Mesothelin showed a sensitivity of 0.73 (CI, 0.68-0.77) and a specificity of 0.90 (CI, 0.84-0.93). In conclusion, some of the recently emerging biomarkers are close to 1.00 specificity. Their moderate sensitivity on their own, however, can be significantly improved by the use of 2 biomarkers, such as a combination of BAP1 and CDKN2A with fluorescence in situ hybridization or a combination of BAP1 and MTAP immunohistochemistry.


Asunto(s)
Neoplasias Pulmonares , Mesotelioma Maligno , Mesotelioma , Neoplasias Pleurales , Biomarcadores de Tumor/metabolismo , Transportador de Glucosa de Tipo 1/genética , Homocigoto , Humanos , Hibridación Fluorescente in Situ , Neoplasias Pulmonares/patología , Mesotelioma/diagnóstico , Mesotelioma/genética , Mesotelioma/patología , Neoplasias Pleurales/diagnóstico , Eliminación de Secuencia
13.
Trop Med Infect Dis ; 8(1)2022 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-36668914

RESUMEN

Dengue virus (DENV) antibody assays frequently cross-react with sera from individuals who have been infected with or vaccinated against related flaviviruses. The goal of this study was to determine the specificity of two DENV ELISAs with sera from individuals vaccinated against yellow fever virus (YFV) and Japanese encephalitis virus (JEV). The Panbio and the Novatec Dengue IgG ELISAs were tested with sera obtained 3-4 weeks or 0.5-6 years after YFV or JEV vaccination and the diagnostic specificity of the assays was determined. As controls, the sera were tested using DENV, YFV, JEV, Zika and West Nile virus neutralization assays. The diagnostic specificity of the Panbio and the Novatec ELISA with sera from YFV-vaccinated subjects was 98.2% and 88.2%, respectively. Cross-reactions were rare in the first 4 weeks despite high YFV-neutralizing antibody titers and were mostly found later. The specificity of the Panbio and Novatec assays with sera from JEV-vaccinated individuals was 100% and 92.9%. Cross-reactions occurred in the early time period after vaccination. The measurement values of the two ELISAs correlated strongly. Thus, the Panbio ELISA showed higher diagnostic specificity and may be suitable for seroprevalence studies in areas with high disease prevalence.

14.
Acta Trop ; 226: 106251, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34808116

RESUMEN

Strongyloides stercoralis is a parasite that causes strongyloidiasis worldwide. It may lead to a life-long infection in immunocompetent people and hyperinfection in immunosuppressed patients. A point-of-care (POC) rapid test is helpful for patient diagnosis in resource-limited settings and as a detection tool in elimination/control programs. Previously, we reported a rapid IgG4 dipstick test (Ss Rapid®) for Strongyloides suitable for a laboratory setting. A POC cassette format of the test, which is field-applicable, has since been developed. Here, we report on a laboratory-based evaluation of the Ss Rapid® cas sette test on 285 sera. We assessed the diagnostic sensitivity of the Ss Rapid® cas sette with 32 sera, comprising samples from larval and/or DNA positive individuals from three countries. Additionally, we also tested samples from 33 seropositive endemic areas residents. We evaluated the diagnostic specificity of the test using 220 samples, comprising sera from other infections (n = 101), allergy cases with high IgE antibodies (n = 4), and blood donors (n = 115). The test showed high diagnostic sensitivity (97%, 31/32), and all sera of the seropositive endemic residents were reactive. It also showed high diagnostic specificity (94.5%, 208/220), and all false-positive samples tested negative after sera adsorption using recombinant NIE-coated microsphere beads. Additionally, we showed that the test worked with spiked whole blood samples. The study results showed that the SsRapid® cas sette test merits further laboratory and field evaluations.


Asunto(s)
Strongyloides stercoralis , Estrongiloidiasis , Animales , Anticuerpos Antihelmínticos , Ensayo de Inmunoadsorción Enzimática , Humanos , Sistemas de Atención de Punto , Sensibilidad y Especificidad , Estrongiloidiasis/diagnóstico
15.
Hematol Rep ; 13(3): 9037, 2021 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-34733448

RESUMEN

Skeletal disease is common in multiple myeloma. We investigated the inter-observer agreement and diagnostic accuracy of spinal fractures diagnosed by computer tomography (CT) and magnetic resonance imaging (MRI) from 12 myeloma patients. Two radiologists independently assessed the images. CT, MRI, and other images were combined to a gold standard. The inter-observer agreement was assessed with Cohen's kappa. Radiologist 1 diagnosed 20 malignant spinal fractures on CT and 26 on MRI, while radiologist 2 diagnosed 12 malignant spinal fractures on CT and 22 on MRI. In comparison the gold standard diagnosed 10 malignant spinal fractures. The sensitivity for malignant fractures varied from 0.5 to 1 for CT and MRI, and the specificity varied from 0.17 to 0.67. On MRI, the specificity for malignant spinal fractures was 0.17 for both radiologists. The inter-observer agreement for malignant spinal fractures on CT was -0.42 (Cohen's kappa) and -0.13 for MRI, while for osteoporotic fractures it was -0.24 for CT and 0.53 for MRI. We conclude that malignant spinal fractures were over-diagnosed on CT and MRI. The inter-observer agreement was extremely poor.

16.
Rev Sci Tech ; 40(1): 299-309, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34140723

RESUMEN

To select, interpret, and assess the fitness-for-purpose of diagnostic tests, we need to compare the likelihoods of test results being true vs. false across both infected and non-infected individuals. Diagnostic sensitivity (DSe) and specificity (DSp) report the accuracy of classification in infected and non-infected individuals separately and do not compare these likelihoods directly. Positive and negative predictive values combine these likelihoods, but they also heavily depend on the prevalence in the tested populations and, therefore, cannot be generalised. We propose the adoption of the diagnostic likelihood ratio (LR), which balances the likelihoods of true vs. false results and is population independent. As a relative measure, LR ignores the absolute accuracy of tests, and two tests with different accuracy profiles may have the same LR. This can be easily mitigated by using listed complementary measures of accuracy, including DSe and DSp, or ancillary selection criteria. Overall, LR is a more relevant and universal measure of diagnostic test accuracy, which makes it the logical next-generation measure to adopt. We illustrate the applications and benefits of LR using three assays certified by the World Organisation for Animal Health as serological tests for bovine tuberculosis.


Afin de sélectionner, interpréter et évaluer l'aptitude à l'emploi de tests diagnostiques, nous devons comparer les probabilités de vrais vs faux résultats tant chez les individus infectés que chez les individus non infectés. La sensibilité diagnostique (DSe) et la spécificité diagnostique (DSp) correspondent à la capacité de classifier correctement les individus infectés ou non infectés séparément, sans toutefois comparer directement ces probabilités. Les valeurs prédictives positive et négative combinent ces probabilités mais sont fortement tributaires de la prévalence au sein de la population testée et par conséquent ne peuvent être généralisées. Les auteurs proposent d'adopter le ratio de vraisemblance diagnostique (likehood ratio : LR), qui compare les probabilités que les résultats diagnostiques soient vrais ou faux indépendamment de la population testeé. En tant que mesure relative, le LR ignore l'exactitude absolue d'un test, de sorte que deux tests présentant des profils d'exactitude différents peuvent avoir le même LR. Ces cas peuvent être résolus en faisant appel à d'autres mesures d'exactitude, y compris la DSe et la DSp, ou à des critères alternatifs. Globalement, le LR constitue une mesure plus pertinente et universelle, ce qui justifie son adoption comme la nouvelle génération de mesure pour l'exactitude diagnostique. Les auteurs illustrent les applications et les avantages du LR à travers l'exemple de trois tests validés par l'Organisation mondiale de la santé animale pour la sérologie de la tuberculose bovine.


Para seleccionar e interpretar pruebas de diagnóstico y valorar en qué medida cumplen su propósito debemos poder comparar la probabilidad de que los resultados que deparen sean verdaderos o falsos, y ello en individuos tanto infectados como no infectados. La sensibilidad y la especificidad de diagnóstico dan cuenta de la exactitud con que se pueden catalogar los individuos como infectados y no infectados separadamente, sin comparación directa entre estas dos probabilidades. Los valores predictivos positivos y negativos combinan ambas probabilidades, pero son muy dependientes de la prevalencia en la población analizada, por lo que no es posible generalizarlos. Los autores proponen que se adopte la razón de verosimilitudes (likelihood ratio: LR) del diagnóstico, que da cuenta de la probabilidad de obtener un resultado verdadero frente a la de obtener un resultado falso con independencia de la población de que se trate. Siendo un parámetro relativo, la LR es ajena a la exactitud absoluta de la prueba. Puede ocurrir por lo tanto que dos pruebas con distintas características de exactitud presenten la misma LR, extremo que se puede paliar fácilmente empleando una lista de medidas complementarias de la exactitud, entre ellas la DSe y la DSp, o criterios de selección auxiliares. Globalmente, la LR ofrece una medida más pertinente y universal de la exactitud de una prueba de diagnóstico, con lo que es lógico que sea adoptada como parámetro de próxima generación. Los autores ilustran las aplicaciones y ventajas de la LR aplicándola a tres ensayos aprobados por la Organización Mundial de Sanidad Animal como pruebas serológicas de detección de la tuberculosis bovina.


Asunto(s)
Pruebas Diagnósticas de Rutina , Animales , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Pruebas Serológicas/veterinaria
17.
Rev Sci Tech ; 40(1): 261-270, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34140725

RESUMEN

Before tools became available to consider diagnostic test validation studies where a 'gold-standard' is not available, new diagnostic tests were compared to a reference standard assumed to be highly accurate if not perfect. This paper reviews such 'traditional' situations with examples and methods of study design and analysis. Three situations are described, two where a perfect reference is available for either positive or negative animals, and one where the reference is perfect for both. Thus, here the authors review circumstances to be considered when validating a diagnostic test with a credible reference standard. An appropriate study design requires an unbiased selection of animals from the population to which a new test will be applied. Examples for calculating sample size and data analysis are provided. Finally, the authors discuss situations where it may be appropriate to include influential variables ('covariates') in a diagnostic test validation study..


Avant la mise au point d'outils permettant de concevoir des études de validation pour des tests candidats en l'absence d'un étalon de référence à l'exactitude parfaite (référence absolue ou gold standard), les tests à valider étaient comparés à un étalon de référence censé présenter un niveau élevé d'exactitude, à défaut d'être parfait. Les auteurs décrivent ces situations « classiques ¼ en donnant quelques exemples et en précisant les méthodes employées pour la conception et l'analyse de ces études. Ils décrivent trois situations : dans deux d'entre elles, un étalon de référence parfait existe, soit pour les animaux positifs, soit pour les animaux négatifs ; dans la troisième situation, l'étalon de référence est parfait pour les deux catégories. Ainsi, les circonstances prises en compte ici sont celles de la validation d'un test diagnostique au moyen d'un réactif de référence crédible. Une conception d'étude appropriée passe par une sélection non biaisée des individus composant l'échantillon au sein de la population animale à laquelle sera appliqué le test. Les auteurs donnent quelques exemples de calcul de la taille de l'échantillon et d'analyse des données. Enfin, ils examinent les situations où il peut être opportun d'inclure des variables influentes (« covariance ¼) dans l'étude de validation d'un test diagnostique.


Antes de que apareciesen herramientas que permiten juzgar los estudios de validación de pruebas de diagnóstico en ausencia de un modelo o patrón de calibración, las nuevas pruebas de diagnóstico eran comparadas con un patrón de referencia considerado muy exacto, cuando no perfecto. Los autores se refieren aquí a este tipo de situaciones "clásicas", exponiendo ejemplos y métodos de diseño de estudios y análisis de los datos obtenidos. Los autores describen tres tipos de situación: cuando se dispone de una referencia perfecta para animales positivos; cuando se dispone de una referencia perfecta para animales negativos; y cuando la referencia es perfecta para ambos casos. Para cada tipo de situación examinan los aspectos que hay que tener en cuenta al validar una prueba de diagnóstico con un patrón de referencia fiable. El diseño adecuado de un estudio exige una selección no sesgada de los animales a partir de una población a la que vaya a aplicarse la nueva prueba. Los autores ofrecen ejemplos del modo de calcular el tamaño muestral y analizar los datos de un estudio. Por último, examinan situaciones en las que pueda ser conveniente incluir en el estudio de validación uno o más factores que puedan influir (covariables).


Asunto(s)
Pruebas Diagnósticas de Rutina , Animales , Pruebas Diagnósticas de Rutina/veterinaria , Estándares de Referencia , Sensibilidad y Especificidad
18.
Rev Sci Tech ; 40(1): 287-298, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34140743

RESUMEN

Reporting and design standards are key indicators of the quality of diagnostic accuracy (validation) studies but, with the exception of aquatic animal diseases and paratuberculosis in ruminants, there is limited guidance for designing these studies in animals. There is, therefore, a need for generic guidelines that are based on disease characteristics, such as mode of transmission, latent period and pathogenesis. Comprehensive, clear and transparent reporting of primary test accuracy studies for diseases listed by the World Organisation for Animal Health (OIE) has value for the end users of diagnostic tests and, ultimately, for decision-makers, who require systematic reviews and meta-analysis of multiple tests for specified diseases and testing purposes. The recent publication of reporting standards for Bayesian latent class models, to analyse test-accuracy data from naturally occurring disease events, fills an important gap as these methods are being increasingly used for OIE-listed diseases. Adherence to design and reporting standards, as well as to guidelines, helps to ensure that research funding for test validation studies is used appropriately and that the strengths and limitations of single tests or test combinations are made clear to test users. The authors provide a review of key points that are often overlooked or misinterpreted in test validation studies, as well as two concrete examples of good practice for use as a reference point for future studies.


Les normes de notification et de conception sont des indicateurs essentiels de la qualité des études de validation des tests destinées à déterminer leur exactitude diagnostique ; or, en dehors des maladies des animaux aquatiques et de la paratuberculose chez les ruminants, il n'existe guère de lignes directrices pour concevoir ce type d'études pour les tests utilisés en santé animale. À la connaissance des auteurs, il n'existe pas non plus de normes de conception applicables aux études de validation en santé humaine. Par conséquent, il conviendrait de disposer de lignes directrices génériques fondées sur les caractéristiques des maladies telles que leurs modalités de transmission, leur période de latence et leur pathogénie. Une notification complète, claire et transparente des études d'exactitude des tests primaires pour les maladies listées par l'Organisation mondiale de la santé animale (OIE) serait une aide précieuse pour les utilisateurs finaux des tests de diagnostic, mais aussi pour les responsables de l'élaboration des politiques, dont les décisions reposent sur des examens et des méta-analyses systématiques couvrant un grand nombre de tests pour certaines maladies ou pour certains usages d'un test. La publication récente des normes de notification applicables aux modèles bayésiens à classe latente pour analyser les données de performance d'un test à partir de foyers naturels de maladie comble une lacune importante dans la mesure où ces méthodes sont de plus en plus utilisées pour les maladies listées par l'OIE. L'adhésion à des normes de conception et de notification ainsi qu'à des lignes directrices en la matière permettra de garantir que les fonds alloués aux études de validation des tests sont bien utilisés et que les atouts et les limitations de certains tests individuels ou associations de tests sont clairement perçus par les utilisateurs. Les auteurs passent en revue certains points essentiels qui sont souvent ignorés ou mal interprétés lors des études de validation des tests et proposent deux exemples concrets de bonnes pratiques qui pourront servir de références pour les études à venir.


Las normas de comunicación y diseño son indicadores básicos de la calidad de los estudios encaminados a determinar la exactitud de diagnóstico (validación) pero, con la excepción de las enfermedades de los animales acuáticos y la paratuberculosis en rumiantes, hay escasas directrices que se apliquen al diseño de esos estudios en animales. Además, hasta donde saben los autores, en el ámbito de la salud humana no hay normas de diseño. De ahí la necesidad de directrices genéricas que estén basadas en las características de las enfermedades, como modo de transmisión, período de latencia o patogénesis. La comunicación exhaustiva, clara y transparente de estudios primarios sobre la exactitud de pruebas de diagnóstico de enfermedades incluidas en las listas de la Organización Mundial de Sanidad Animal (OIE) reviste utilidad no solo para los usuarios finales de la prueba, sino también, en última instancia, para los órganos decisorios, que necesitan metaanálisis y estudios sistemáticos de múltiples pruebas que se apliquen a una u otra enfermedad y sirvan para una u otra finalidad. La reciente publicación de normas de comunicación de modelos bayesianos de clases latentes para analizar los datos de exactitud de pruebas a partir de episodios de enfermedad de origen natural viene a colmar una importante laguna, en la medida en que estos métodos se aplican cada vez más al diagnóstico de enfermedades incluidas en las listas de la OIE. El cumplimiento de las normas de diseño y comunicación, y también de las directrices, ayuda a garantizar que los fondos de investigación destinados a estudios de validación de pruebas sean utilizados debidamente y que el usuario final de una prueba reciba información clara sobre los puntos fuertes y las limitaciones de una prueba o combinación de pruebas. Los autores pasan revista a los principales aspectos que se suelen pasar por alto o malinterpretar en los estudios de validación de pruebas y ofrecen dos ejemplos concretos de buenas prácticas que se pueden utilizar como referencia en futuros estudios.


Asunto(s)
Enfermedades de los Animales , Pruebas Diagnósticas de Rutina , Enfermedades de los Animales/diagnóstico , Animales , Teorema de Bayes , Pruebas Diagnósticas de Rutina/veterinaria , Salud Global , Rumiantes
19.
J Cutan Pathol ; 48(11): 1342-1346, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34075607

RESUMEN

BACKGROUND: Early and accurate diagnosis of systemic amyloidosis (SA) is critical for optimal patient outcomes. Biopsy of clinically uninvolved skin and subcutaneous tissue including abdominal skin punch biopsy (ASPB) is often used as a surrogate for affected organ sampling. There is a lack of published data on the sensitivity and specificity of ASPB for diagnosing SA. METHODS: Retrospective chart review between 2000 and 2020 of all ASPB was performed to diagnose SA. Amyloid deposition was confirmed by Congo red stain. Study group includes patients with histopathologically and clinically confirmed diagnosis of SA. Control group includes patients without histopathology of amyloid deposition and no clinical SA. RESULTS: Forty-one patients meeting inclusion criteria were analyzed; 23 study group and 18 control group patients. The overall diagnostic sensitivity of ASPB was 43% (95% CI 23%-66%) and the specificity 100% (95% CI 81%-100%). The AL amyloidosis diagnostic sensitivity was 64% (95% CI 35%-87%). ASPB >10 mm in depth had 100% (95% CI 54%-100%) sensitivity compared to 24% for depth ≤10 mm (P = .002). CONCLUSIONS: ASPB is a minimally invasive and highly specific method of diagnosing SA. It is particularly sensitive for diagnosing AL amyloidosis and the diagnostic sensitivity can be significantly improved with adequate biopsy depth and diameter.


Asunto(s)
Biopsia/métodos , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/diagnóstico , Abdomen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Piel/patología
20.
J Fish Dis ; 44(8): 1147-1153, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33837562

RESUMEN

Diagnostic accuracy of pathogen detection depends upon the selection of suitable tests. Problems can arise when the selected diagnostic test gives false-positive or false-negative results, which can affect control measures, with consequences for the population health. The aim of this study was to compare sensitivity of different diagnostic methods IHC, PCR and qPCR detecting Tetracapsuloides bryosalmonae, the causative agent of proliferative kidney disease in salmonid fish and as a consequence differences in disease prevalence. We analysed tissue from 388 salmonid specimens sampled from a recirculating system and rivers in the Czech Republic. Overall prevalence of T. bryosalmonae was extremely high at 92.0%, based on positive results of at least one of the above-mentioned screening methods. IHC resulted in a much lower detection rate (30.2%) than both PCR methods (qPCR32: 65.4%, PCR: 81.9%). While qPCR32 produced a good match with IHC (60.8%), all other methods differed significantly (p < .001) in the proportion of samples determined positive. Both PCR methods showed similar sensitivity, though specificity (i.e., the proportion of non-diseased fish classified correctly) differed significantly (p < .05). Sample preservation method significantly (p < .05) influenced the results of PCR, with a much lower DNA yield extracted from paraffin-embedded samples. Use of different methods that differ in diagnostic sensitivity and specificity resulted in random and systematic diagnosis errors, illustrating the importance of interpreting the results of each method carefully.


Asunto(s)
Pruebas Diagnósticas de Rutina/veterinaria , Enfermedades de los Peces/diagnóstico , Myxozoa/aislamiento & purificación , Oncorhynchus mykiss , Enfermedades Parasitarias en Animales/diagnóstico , Parasitología/métodos , Trucha , Animales , Acuicultura , República Checa/epidemiología , Pruebas Diagnósticas de Rutina/métodos , Enfermedades de los Peces/epidemiología , Enfermedades de los Peces/parasitología , Enfermedades Parasitarias en Animales/epidemiología , Enfermedades Parasitarias en Animales/parasitología , Prevalencia , Ríos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA