RESUMEN
Graphene is a promising biomaterial. However, its dispersion in aqueous medium is challenging. This study aimed to modify graphene nanoparticles with L-dopa to improve the properties of experimental dental adhesives. Adhesives were formulated with 0% (control), 0.25%, 0.5%, and 0.75% of graphene, modified or not. Particle modification and dispersion were microscopically assessed. Degree of conversion was tested by Fourier-transform infrared spectroscopy. Flexural strength and modulus of elasticity were evaluated by a 3-point flexural test. Bond strength was tested by shear. To test water sorption/solubility, samples were weighed during hydration and dehydration. Antibacterial activity was tested by Streptococcus mutans colony-forming units quantification. Cytotoxicity on fibroblasts was evaluated through a dentin barrier test. The modification of graphene improved the particle dispersion. Control presented the highest degree of conversion, flexural strength, and bond strength. In degree of conversion, 0.25% of groups were similar to control. In bond strength, groups of graphene modified by L-dopa were similar to Control. The modulus of elasticity was similar between groups. Cytotoxicity and water sorption/solubility decreased as particles increased. Compared to graphene, less graphene modified by L-dopa was needed to promote antibacterial activity. By modifying graphene with L-dopa, the properties of graphene and, therefore, the adhesives incorporated by it were enhanced.
RESUMEN
OBJECTIVES: To evaluate the clinical performance of posterior restorations over wet and dry dentin with an etch-and-rinse adhesive after 36 months of clinical service. METHODS: Forty-five participants were recruited, each one had at least two posterior teeth that needed restoration. Ninety restorations were placed on Class I or Class II cavities. For the restoration protocol, a simplified etch-and-rinse adhesive (Adper Single Bond 2) was applied over wet (WD) or dry dentin (DD) and later restored with a bulk-fill composite (Filtek Bulk Fill) under rubber dam isolation. Each restoration was evaluated using the World Dental Federation (FDI) criteria after 6, 12, and 36 months of clinical service, regarding the following principal restoration characteristics: postoperative sensitivity, marginal discoloration, marginal adaptation, fracture of material and retention, and recurrence of caries. Kruskal Wallis analysis of variance rank (α = 0.05) and Kaplan-Meier survival analysis were used for statistical analysis. RESULTS: After 36 months of clinical evaluation, no significant difference between groups was observed in each FDI criterion (p > 0.05). Twenty restorations (WD=10, DD=10) showed minor marginal staining, and twenty-two restorations (WD=11, DD=11) presented small marginal adaptation defects (p > 0.05). Four restorations were lost (WD = 2, DD = 2) and the fracture rates (95% confidence interval) were 94.9% for each one, without significant difference between wet and dry dentin (p > 0.05). SIGNIFICANCE: The degree of dentin moisture does not seem to affect the clinical performance of a simplified etch-and-rinse adhesive in posterior restorations when the adhesive is applied vigorously over the dentine surface.
Asunto(s)
Caries Dental , Cementos Dentales , Humanos , Recubrimientos Dentinarios/química , Cementos de Resina , Restauración Dental Permanente/métodos , Resinas Compuestas/química , Caries Dental/terapia , Dentina , Adaptación Marginal DentalRESUMEN
Dental fluorosis can cause changes in the enamel surface, conditioning its functionality and esthetics. The application of dental adhesives is a treatment option; however, their use on fluorotic teeth can result in limitations. The aim of this study was to compare the shear bond strength of two different adhesives, one with 10-MDP and one without 10-MDP, in different degrees of dental fluorosis.This is an in vitro study on dental enamel samples, a total of 180 samples with the inclusion criteria were treated, randomly divided into two groups of 90, according to the type of dental adhesive, where each group was again divided into three groups of 30 samples, representing different degrees of dental fluorosis according to the Thylstrup-Fejerskov index (Group I: TF1 and TF2; Group II: TF3; Group III: TF4). Normality tests, two-factor ANOVA, and post-hoc tests were used to determine differences between the groups, with a significance level of 95%. As results, a statistically significant difference was shown between the use of dental adhesive with 10-MDP and the three groups of dental fluorosis (p=0.011), in addition, a Tukey post-hoc test on the groups treated with 10-MDP adhesive revealed a statistically significant difference between group I versus group II, and group I versus group III, (p=<0.05). It is concluded that the use of adhesive systems with 10-MDP presents a better shear bond strength on enamel with dental fluorosis grades I and II in the Thylstrup-Fejerskov index.
La fluorosis dental puede ocasionar cambios en la superficie del esmalte, condicionando su funcionalidad y estética, la aplicación de adhesivos dentales es una opción de tratamiento, sin embargo, su uso en dientes fluoroticos puede resultar en limitaciones. El objetivo de este estudio consistió en comparar la fuerza de adhesión a la cizalladura de dos diferentes adhesivos, uno con 10-MDP y otro sin 10-MDP, en diferentes grados de fluorosis dental. Se trata de un estudio in vitro en muestras de esmalte dental, un total de 180 muestras con los criterios de inclusión fueron tratadas, aleatoriamente divididas en dos grupos de 90, de acuerdo al tipo de adhesivo dental, donde cada grupo fue dividido nuevamente en tres grupos de 30 muestras, representando diferentes grados de fluorosis dental según el índice de Thylstrup- Fejerskov (Grupo I: TF1 y TF2; Grupo II: TF3; Grupo III: TF4). Para determinar diferencias entre los grupos se utilizaron pruebas de normalidad, ANOVA de dos factores, y pruebas post-hoc, con un nivel de significancia de 95%. Como resultados, se mostró una diferencia estadísticamente significativa entre el uso de adhesivo dental con 10- MDP y los tres grupos de fluorosis dental (p=0.011), además, una prueba post hoc de Tukey sobre los grupos tratados con adhesivo 10-MDP revelaron una diferencia estadísticamente significativa entre el grupo I frente al grupo II, y el grupo I frente al grupo III, (p=<0.05) Se concluye que el uso de sistemas adhesivos con 10-MDP presentan una mejor resistencia de adhesión al cizallamiento en esmalte con grados de fluorosis dental I y II en el índice de Thylstrup-Fejerskov
Asunto(s)
Recubrimientos Dentinarios/uso terapéutico , Fluorosis Dental/diagnóstico , Cementos de ResinaRESUMEN
This study aimed to evaluate the antibacterial effect, cytotoxicity, and microtensile bond strength of an adhesive system containing silver nanoparticles (NAg). NAg was synthesized and incorporated (500 and 1000 ppm) into Scotchbond Multi-Purpose (SBMP) primer and bond. A microtensile bond test (µTBS) was performed after 24 h and 1 year. The adhesive interface was characterized using a confocal Raman microscope. The antibacterial activity was assessed using agar diffusion and biofilm inhibition assays (S. mutans). MTT assay was used to assess the cytotoxicity of NAg-conditioned culture media on human dental pulp stem cells (hDPSCs). The results were statistically analyzed using analysis of variance and Tukey's tests (α = .01). Incorporating 500 and 1000 ppm of NAg in the SBMP did not affect the µTBS after 24 h (p > 0.05). However, in the 1 year evaluation, 500 ppm presented the highest µTBS values (p < 0.05). The addition of NAg at 500 and 1000 ppm in the primer and bond led to larger inhibition halos and colony-forming units than the control (p < 0.05). For the unpolymerized and polymerized groups, the combination of primer and bond presented the highest cytotoxic effects on hDPSCs (p < 0.05). In conclusion, incorporating 500 or 1000 ppm of NAg into an etch-and-rinse adhesive system led to an antibacterial effect without altering the cytotoxicity. SBMP at 500 ppm presented a higher µTBS at 1 year.
Asunto(s)
Recubrimiento Dental Adhesivo , Nanopartículas del Metal , Humanos , Nanopartículas del Metal/química , Plata/farmacología , Plata/química , Cementos de Resina/farmacología , Cementos de Resina/química , Antibacterianos/farmacología , Resistencia a la Tracción , Cementos Dentales/farmacología , Cementos Dentales/química , Ensayo de Materiales , Recubrimientos Dentinarios/farmacología , Recubrimientos Dentinarios/química , DentinaRESUMEN
Objective: Evaluate the mechanical properties of experimental adhesive models with different photoinitiators (PI) polymerized by LED units of different power densities. Material and Methods: Three groups of adhesive models based on HEMA/BisGMA (45/55) were prepared in association with different PI combinations: G2 (control) 2 PI: 0.5% CQ, 0.5% EDMAB; G3 - 3 PI: 0.5% CQ; 0.5% DMAEMA, 0.5% DPIHP; G4 - 4 PI: 0.5% CQ; 0.5% EDMAB; 0.5% DMAEMA; 0.5% DPIHP. The three formulations were polymerized at two different LED power densities: 550 mW/cm2 and 1200 mW/cm2. The degree of conversion (DC) of adhesive monomers was monitored in situ through the FTIR for 600 s. Specimens were prepared for each formulation for analysis mong adhesive systems (G2
Objetivo: Avaliar as propriedades mecânicas de modelos adesivos experimentais com diferentes fotoiniciadores (PI) polimerizados por unidades de LED de diferentes densidades de energia. Material e Métodos: Três grupos de modelos adesivos baseados em HEMA/BisGMA (45/55) foram preparados em associação com diferentes combinações de PI: G2 (controle) 2 PI: 0,5% CQ, 0,5% EDMAB; G3 - 3PI: 0,5% CQ; 0,5% DMAEMA, 0,5% DPIHP; G4 - 4 PI: 0,5% CQ; 0,5% EDMAB; 0,5% DMAEMA; 0,5% DPIHP. As três formulações foram polimerizadas em duas densidades de potência de LED: 550 mW/cm2 e 1200 mW/cm2. O grau de conversão (DC) dos monômeros adesivos foi monitorado in situ através do FTIR durante 600 s. Amostras foram preparadas para cada formulação para análise de resistência à flexão (FS), módulo de elasticidade (ME), sorção (SOR) e solubilidade (SOL). Os dados foram submetidos aos testes ANOVA 2-fatores e Tukey (5%). Resultados: DC: houve diferença significativa entre os sistemas adesivos (G2Asunto(s)
Radiación
, Recubrimientos Dentinarios
, Curación por Luz de Adhesivos Dentales
, Fotoiniciadores Dentales
RESUMEN
Introducción: se realizó una revisión bibliográfica con el objetivo de conocer, analizar y comparar los diferentes tipos de adhesivos de octava generación que se encuentran en el mercado y la diferencia que existe entre cada uno. Los adhesivos universales han demostrado mejoras en su resistencia, sobre todo en las técnicas de aplicación y en las propiedades de estos materiales, al mejorar la fuerza adhesiva para que el odontólogo pueda brindar tratamientos restaurativos exitosos. Objetivo: conocer, analizar y comparar los diferentes tipos de adhe- sivos de la octava generación empleados en odontología. Material y métodos: se realizó una búsqueda en las bases de datos electrónicas PubMed, BVS, Redalyc y ScienceDirect. Se utilizaron 32 artículos que cumplieron con los criterios predeterminados y la especificidad reque- rida para la pregunta de investigación. Conclusiones: se demostró que la tecnología cada día avanza, sobre todo en el área de los adhesivos, ya que éstos son de mucha utilidad en el día a día del odontólogo; es importante conocer cada uno de éstos, puesto que es un poco complejo seleccionar el correcto, mas no el uso. En la actualidad, existen diversas opciones por las que el odontólogo puede optar, es por ello que el pro- fesional debe estar capacitado sobre cada una de las diferentes marcas existentes y, de acuerdo al tratamiento, debe elegir cuál es mejor utilizar en una rehabilitación. Es importante para el odontólogo conocer estos materiales, ya que esto lo beneficiará al momento de llevar un plan de tratamiento restaurador (AU)
Introduction: a bibliographic review was carried out to learn about, analyze, and compare the different types of eighth-generation adhesives on the market and the difference between each one. Universal adhesives have demonstrated improvements in their resistance, especially in the application techniques and properties of these materials, improving the adhesive strength so that the dentist can provide successful restorative treatments. Objective: to know, analyze and compare the different types of eighth-generation adhesives used in dentistry. Material and methods: a search was made of the following electronic databases: PubMed, BVS, Redalyc, ScienceDirect. Finally, 32 articles that met the predetermined criteria and the specificity required for the research question were used. Conclusions: it was demonstrated that technology is advancing every day, especially in the area of adhesives since these are very useful in the daily life of the dentist. It is important to know each one of these since it is a little complex at the moment of selecting the correct one, but not the use. Currently, there are several options that the dentist can choose, which is why the professional must be trained on each of the various existing brands and according to the treatment which is the best to use at the time of rehabilitation. The dentist needs to know these materials since they will benefit him/her when carrying out a restorative treatment plan (AU)
Asunto(s)
Tecnología Odontológica/tendencias , Recubrimientos Dentinarios , Propiedades de Superficie , Grabado Ácido Dental/métodos , Fuerza Compresiva , Esmalte Dental/efectos de los fármacos , Resistencia al Corte , Dentina/efectos de los fármacos , Nanopartículas , Resistencia FlexionalRESUMEN
Objective: The aim of this study was to evaluate the effect of STMP as biomimetic analog of dentin matrix on the dentin bond strength submitted to artificial cariogenic challenge over time. Material and Methods: The total number of teeth used in the experiment was 60 teeth, which were divided into 6 groups (n = 10). Of these total amount, 10 teeth were not submitted to the artificial cariogenic challenge (ACC), serving as control group (Sound Dentin - SD) while the other 50 were submitted to an ACC (7d/37ºC), being treated with treatment solutions according to each group: SD- deionized water/sound dentin, CD- deionized water/ artificial caries dentin, GIII- STMP, GIV- STMP + Ca(OH)2, GV- STMP + NaF, and GVI- NaF. After treatments (24h), the specimens were restored (Adper Single Bond Universal + Filtek Z250), to obtain resindentin sticks with a cross sectional area of 0.8mm2, approximately. Two-third of these sticks were stored in artificial saliva (37°C) for analyzes after 6 and 12 months. The 1/3 remains were subjected to µTBS test (baseline). Data were analyzed by two-way ANOVA and Tukey tests (p<0.05). Results: In general, the highest µTBS values were obtained in sound condition (SD), while the artificial caries condition (CD) determined minimum values. Groups treated with NaF (with or without STMP- GV and GVI) were not able to improve adhesion over time. Only the use of STMP + Ca(OH)2(GIV) improved the µTBS compared to the others caries-challenged dentin after 1 year. The adhesive failure pattern was predominant in all time. Conclusion: The use of the STMP associated with Ca(OH)2 seems to be a viable therapeutic strategy conciliating the biomimetizing capacity to the adhesive process satisfactorily even its performance is not superior to initial condition (AU)
Objetivo: O objetivo deste estudo foi avaliar o efeito do STMP como análogo biomimético da matriz dentinária na resistência de união à dentina submetida a desafio cariogênico artificial ao longo do tempo. Material e Métodos:foram utilizados um total de 60 dentes neste experimento, os quais foram divididos em 6 grupos (n = 10). Desse total, 10 dentes não foram submetidos ao desafio cariogênico artificial (DCA), servindo como grupo controle (Dentina Hígida - DH) enquanto os outros 50 foram submetidos ao DCA (7d / 37ºC), sendo tratados com soluções de tratamento específicas para cada grupo: DH- água deionizada / dentina hígida, DC- água deionizada / dentina submetida ao DCA, GIII- STMP, GIV- STMP + Ca(OH)2, GV- STMP + NaF e GVI- NaF. Após os tratamentos (24h), os corpos-de-prova foram restaurados (Adper Single Bond Universal + Filtek Z250), para obtenção de palitos de resina-dentina com área transversal de aproximadamente 0,8mm2. Dois terços desses palitos foram armazenados em saliva artificial (37°C) para análises após 6 e 12 meses. Os outros 1/3 foram submetidos ao teste µTBS (baseline). Os dados foram analisados por ANOVA a dois fatores e testes de Tukey (p <0,05). Resultados:Em geral, os maiores valores de µTBS foram obtidos em condição hígidas (DH), enquanto a condição subtmetidas ao DCA determinou os menores valores. Os grupos tratados com NaF (com ou sem STMP associado -GV e GVI) não foram capazes de melhorar a resistência de união, ao longo do tempo. Somente o uso de STMP + Ca (OH)2(GIV) melhorou o µTBS em comparação com as outras condições desafiadas por cárie após 1 ano. O padrão de falha adesiva foi predominante em todos os tempos. Conclusão: O uso do STMP associado ao Ca (OH)2 parece ser uma estratégia terapêutica viável conciliando a capacidade biomimetizante ao processo adesivo de forma satisfatória mesmo que seu desempenho não seja superior à condição inicial.(AU)
Asunto(s)
Humanos , Inhibidores de Proteasas , Recubrimientos Dentinarios , DentinaRESUMEN
Purpose: The main goal of this study was to evaluate the impact of different ionizing radiation doses on the mineral (carbonate/phosphate ratio, crystallinity index [CI]) and organic (amide III/phosphate, amide I sub-band ratios) structures, as well as the microhardness, of enamel and dentin, along with their influence on the bonding strength stability of the etch-and-rinse (ER) and self-etch (SE) dental adhesive strategies.Materials and methods: Enamel and dentin human tissue specimens were irradiated (with 0, 20, 40, and 70 Gy radiation doses, respectively) and sectioned to perform an attenuated total reflection-Fourier transform IR spectroscopy assay (ATR-FTIR) and the Vickers microhardness (VHN) test to conduct a biochemical and biomechanical evaluation of the tissues. Regarding the adhesive properties, restored enamel and dentin specimens exposed to the same radiation doses were submitted to microshear bond strength (µSBS) tests for enamel in immediate time (IM) and to microtensile bond strength (µTBS) tests after for IM and 12-month (12 M) period of time, Mann-Whitney U tests were implemented, using the ATR-FTIR data for significant differences (α < 0.05), and three- and two-way analyses of variance, along with post-testing, were performed on the µTBS and µSBS data (MPa), respectively (Tukey post hoc test at α = 0.05).Results: The ATR-FTIR results showed a significant decrease (p < .05) in the amide III/phosphate ratio after 20 Gy for the enamel and after 40 Gy for the dentin. The CI was significantly reduced for both tissues after a dose of 70 Gy (p < .05). All radiation doses significantly decreased microhardness values, relative to the respective enamel and dentin controls (p < .05). In both tissues and adhesive strategies, the decrease in bond strength was influenced by ionizing radiation starting from 40 Gy. The ER strategy showed high percentages of enamel cohesive failure. In general, ER in both tissues showed greater and more stable bond strength than SE against increased radiation doses and long term.Conclusions: It is possible to conclude that structural alterations of enamel and dentin are generated by all radiation doses, decreasing the microhardness of dental hard tissues and influencing bond strength over time, starting at 40 Gy radiation dose. The etch-and-rinse strategy demonstrates better adhesive performance but generates cohesive fractures in the enamel.
Asunto(s)
Restauración Dental Permanente , Diente Molar/efectos de la radiación , Radioterapia/efectos adversos , Diente/efectos de la radiación , Esmalte Dental/citología , Esmalte Dental/efectos de la radiación , Dentina/citología , Dentina/efectos de la radiación , Dureza/efectos de la radiación , Humanos , Diente Molar/citologíaRESUMEN
OBJECTIVES: The polymerization of adhesive systems is incomplete and the residual monomers that have been released have a cytotoxic capacity. Some teeth develop into pulp necrosis after composite resin restorations. Considering frequent pulpal inflammation in response to cariogenic bacteria, substances released from the patches could affect the cells of the inflammatory infiltrate and interfere with the mechanisms of defense against microorganisms and protection of pulpal tissue. The aim of this study was to evaluate the effect of substances released by different resinous adhesive systems on cell viability and cytokine expression by human monocytes stimulated in vitro with Streptococcus mutans. DESIGN: Peripheral blood mononuclear cells from 10 healthy subjects were stimulated with S. mutans and then incubated with supernatants obtained from the Single Bond Universal (SBU) or Clearfil SE Bond (CSEB) adhesive systems for eight hours. Staining with Annexin V and 7AAD for analysis of apoptosis were performed and detection of monocytes expressing cytokines IL-1α, IL-6, IL-8, IL-10, IL-12 and TNF-α were performed by flow cytometry. RESULTS: No treatment significantly affected apoptosis in monocytes. SBU supernatant increased the frequency of monocytes expressing IL-8 and decreased the monocytes expressing IL-10. Considering S. mutans-stimulated cells, while SBU increased the frequency of IL-8+ monocytes, CSEB reduced the frequency of IL-6 and TNF-αâ¯positive monocytes. CONCLUSIONS: Products released from SBU seem to induce proinflammatory effects on monocytes while those from CSEB show an anti-inflammatory outcome. These effects may interfere in the control of cytokine-mediated immunoinflammatory pulp reactions, both in the presence and absence of stimulation by cariogenic bacteria.
Asunto(s)
Monocitos , Streptococcus mutans , Resinas Compuestas , Citocinas , Cementos Dentales , Humanos , Leucocitos Mononucleares , Factor de Necrosis Tumoral alfaRESUMEN
Plant-derived compounds incite applications virtually on every biomedical field due to the expedient antioxidant, anti-inflammatory and antimicrobial properties in conjunction with a natural character. Here, quercetin (QCT), a flavonoid with therapeutic potentials relevant to the oral environment, was encapsulated within metal-organic frameworks (MOFs) to address the concept of on-demand release of phytochemicals at the biointerface. We verified the applicability of a microporous MOF (ZIF-8) as a controlled-release system for QCT, as well as investigated the incorporation of QCT@ZIF-8 microparticles into a dental adhesive resin for desirable therapeutic capabilities at the tooth-restoration interface. QCT was encapsulated within the frameworks through a water-based, one-step synthetic process. The resulting QCT@ZIF-8 microparticles were characterized with respect to chemical composition, crystal structure, thermal behavior, micromorphology, and release profile under acidic and physiological conditions. A model dental adhesive formulation was enriched with the bioactive microparticles; both the degree of conversion (DC) of methacrylic double bonds and the polymer thermal behavior were accounted for. The results confirm that crystalline QCT@ZIF-8 microparticles with attractive loading capacities, submicron sizes, high thermal stability and responsiveness to environmental pH change were successfully manufactured. The concentration of QCT@ZIF-8 in the resin system was a key factor to maintain an optimal DC plateau and rate of polymerization. Essentially, one-step encapsulation of QCT in biocompatible ZIF-8 matrices can be easily achieved, and QCT@ZIF-8 microparticles proved as smart platforms to carry bioactive compounds with potential use to prevent microbial and enzymatic degradation of hard tissues and extracellular matrix components.
Asunto(s)
Estructuras Metalorgánicas , Polímeros , Antibacterianos , Flavonoides , PolimerizacionRESUMEN
CONTEXT: Zinc-oxide eugenol (ZOE) is frequently used due to its satisfactory biological response, sedative effect on the pulp, and easy removal. However, literature is very controversial about the influence of the temporary cement-containing eugenol on the bond strength properties. AIMS: This study aims to clarify the literature controversy by evaluating the bond strength of ZOE or ZOE-free applied before bonding procedures and the 7-day resting period after the first session. SETTINGS AND DESIGNS: Twelve recently extracted third molars were randomly divided into three groups: Group 1: Control (without treatment), Group 2: Temp-Bond NE; Group 3: Temp-Bond. SUBJECTS AND METHODS: After temporary restorations, the teeth were immersed in distilled water and stored for 7 days at 37°C. The temporary cement was mechanically removed, and prophylaxis was performed. The adhesive procedures were performed, and a 6-mm-high composite resin block was built. The teeth were immediately stored at 100% relative humidity at 37°C for 24 hours. Specimens with 0.7 (±0.2) mm2 of cross-sectional area were obtained and subjected to a microtensile bond strength (µTBS) test at 1 mm/min until failure. STATISTICAL ANALYSIS USED: Analysis of variance (ANOVA) and Tukey's post hoc test were used for statistical analysis. RESULTS: ZOE or ZOE-free cement did not interfere in the µTBS between resin composite and dentine when used with a two-step-etch-rinse adhesive material, considering 7 days of resting period after the first session, by the ANOVA and Tukey's post hoc test (P < 0.05). CONCLUSIONS: The authors recommend the removal of the temporary cementation at least seven days after the first session and suggest that the clinicians follow-up further studies to use the cement in case its removal is recommended within a longer period.
Asunto(s)
Recubrimiento Dental Adhesivo , Cemento de Óxido de Zinc-Eugenol , Resinas Compuestas , Cementos Dentales , Restauración Dental Provisional , Dentina , Recubrimientos Dentinarios , Eugenol , Ensayo de Materiales , Cementos de Resina , Resistencia a la Tracción , ZincRESUMEN
The aim was to assess dentin adhesion and physicochemical properties of experimental etch-and-rinse and self-etch adhesives doped with epigallocatechin-3-gallate (EGCG), a well-known collagen crosslinker obtained from green tea (Camellia sinensis). Experimental adhesives were prepared without (0 wt%), with 0.1 or 0.5 wt% EGCG addition. Their degree of conversion was surveyed by FTIR, and bar-shaped specimens were tested to obtain flexural strength and modulus initially and after 1-week ethanol storage. Extracted human molars were prepared, bonded, and cut into resin-dentin sticks for microtensile bond strength test, which was conducted after 24 h or 6-month water storage. Statistical analyses were performed with two-way ANOVA and Tukey's test (p < 0.05). Degree of conversion outcomes depicted a significant polymerization reduction by the addition of EGCG in self-etch adhesive in both concentrations. However, only 0.1% reduced the conversion of etch-and-rinse adhesive. Flexural modulus and strength were significantly diminished (p < 0.05) by the addition of both concentrations of EGCG for the two model adhesives. Dentin-bond strength was reduced after aging with the addition of EGCG to self-etch adhesive. Nevertheless, 0.5% EGCG increased the bond strength of etch-and-rinse adhesive after aging, conversely to the significant reduction for EGCG-free control adhesive. In conclusion, EGCG at 0.5% provides optimal improvements on dentin bonding without altering final polymerization of a model etch-and-rinse adhesive.
Asunto(s)
Catequina/análogos & derivados , Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Grabado Ácido Dental , Catequina/química , Resistencia Flexional , Humanos , Técnicas In Vitro , Ensayo de Materiales , Diente Molar , Polimerizacion , Propiedades de Superficie , Resistencia a la TracciónRESUMEN
Introduction: The purpose of this in vitro study was to assess the effects of anatomic root levels, different adhesive strategies and cementation system on bond strength (BS), nano leakage (NL) and degree of conversion (DC) after fiber posts cementation. Methods and Materials: Sixty-six roots of human premolars were endodontically prepared and divided according to the combination of adhesive application technique (manual passive, manual active and active vibratory) and the cementation system (Adper Single Bond 2/RelyX ARC [SBAR] and Single Bond Universal/RelyX Ultimate [SBUL]). Specimens were transversally sectioned into six 1-mm-thick serial slices, which were subjected to BS testing (n=7), to NL analysis using scanning electron microscopy (SEM) after slice immersion in silver nitrate (n=2), and micro-Raman spectroscopy for DC (n=2). Data were analyzed using two-way ANOVA and Bonferroni post-hoc test (α=5%). Results: Bond strength values significantly increased with active vibratory application technique (P<0.001), no significant difference was noted between adhesive systems. The cementation system Single Bond Universal/RelyX Ultimate demonstrated the lowest nano leakage values (P<0.05). The manual active and vibratory application techniques showed statistically higher degree of conversion values than the manual passive technique at the coronal and medium thirds (P<0.05); and the lowest results were observed with manual passive application to Single Bond Universal/RelyX Ultimate (P=0.016). Conclusion: The study concluded that techniques with active application (vibratory and manual) resulted in higher bond strength values. The mode of adhesive application influence the results.
RESUMEN
OBJECTIVES: This study describes the synthesis of piperonyl methacrylate (PipM) and evaluates its effect when used as coinitiator in the photoinitiated radical polymerization of experimental adhesive resins. METHODS: PipM was synthetized through an esterification reaction and characterized by FTIR and 1H NMR spectroscopy. Adhesive resins containing camphorquinone as photoinitiator and PipM or ethyl-4-dimethyl amine benzoate (EDAB) as coinitiators were formulated. Scotchbond Multipurpose (SBMP) adhesive was used as commercial reference. All materials were analyzed for polymerization kinetics, flexural strength, elastic modulus, water sorption/solubility, shear bond strength to bovine enamel and dentin, characterization of hybrid layer by scanning electron microscopy (SEM), microbiological direct contact test, and cytotoxicity. RESULTS: The adhesive with PipM presented higher degree of conversion and lower sorption/solubility when compared with other groups. Shear bond strength to enamel and dentin were similar for PipM and EDAB materials. The percentage of cellular viability was close to 100% and similar in the experimental groups and the commercial reference. CONCLUSIONS: PipM presented similar or superior performance to the tertiary amine used as control, representing a potential alternative coinitiator for photopolymerizable dental materials. CLINICAL SIGNIFICANCE: PipM could be potentially useful in the formulations of adhesive systems with enhanced chemical properties, which could mean improvement in the longevity of composite resin restorations.
Asunto(s)
Recubrimiento Dental Adhesivo , Cementos Dentales , Metacrilatos/química , Animales , Bisfenol A Glicidil Metacrilato , Bovinos , Resinas Compuestas , Materiales Dentales , Recubrimientos Dentinarios , Ensayo de Materiales , Cementos de ResinaRESUMEN
RESUMEN Introducción: No existe un protocolo definitivo para la reparación de cerómeros. Los adhesivos universales debido a su composición e indicaciones pueden ser una alternativa dentro de la reparación de restauraciones poliméricas, pero la asociación de los silanos con los adhesivos universales requiere más investigación. Objetivo: Evaluar y comparar la resistencia de unión de dos adhesivos universales en la interfase cerómero-resina, asociado o no a un agente silano. Material y métodos: Se realizaron seis bloques de cerómero y se trataron según las siguientes variables: (A) sin tratamiento, (B) agente silano, (C) adhesivo universal 1 + silano, (D) adhesivo universal 1, (E) adhesivo universal 2 + silano, (F) adhesivo universal 2 (n = 10). Se unió resina compuesta a dichas superficies y se realizó prueba de microtensión. El tipo de falla se evaluó con estereomicroscopio. Resultados: Los valores de resistencia de unión de los grupos fueron estadísticamente diferentes (p < 0.05), excepto entre ambos adhesivos universales evaluados. El grupo B presentó los valores más altos de resistencia adhesiva. Los grupos C y E obtuvieron valores de resistencia adhesiva menores en comparación con los grupos D y F. El tipo de falla predominante fue el adhesivo. Conclusión: El uso asociado de un silano funcional con los adhesivos universales no mejora los valores de resistencia adhesiva, por lo que debería evitarse. Como primera elección se recomienda el silano funcional, y en segundo grado, sólo usar adhesivos universales, pero no asociar los dos materiales en un mismo proceso adhesivo.
ABSTRACT Introduction: There is no definitive protocol for ceromer repairs. Universal adhesives due to their composition and indications may be an alternative for polymeric restorations repair. But the association of silanes with universal adhesives requires more research. Objective: To evaluate and compare the bond strength of two universal adhesives in ceromer - resin interface, associated or not with a silane agent. Material and methods: Six ceromer blocks were made and treated according to the following variables: (A) No treatment, (B) Silane agent, (C) Universal Adhesive 1 + Silane, (D) Universal Adhesive 1, (E) Adhesive Universal 2 + Silane, (F) Universal Adhesive 2 (n = 10). Composite resin was attached to these surfaces and a microtension test was performed. The type of failure was evaluated with a stereomicroscope. Results: The bond strength values of the groups were statistically different (p <0.05), except between both universal adhesives were evaluated. Group (B) presented the highest values of adhesive resistance. Groups (C and E) had lower adhesive strength values compared to groups (D and F). The most prevalent type of failure was the adhesive. Conclusion: The associated use of functional silane to universal adhesives does not improve adhesive strength values, so it should be avoided. As a first choice, functionalsilane is recommended, and in the second degree, only use universal adhesives, but do not associate the two materials in the same adhesive process.
RESUMEN
OBJECTIVES: To evaluate the antibacterial effects, cytotoxicity and microtensile bond strength of an adhesive containing low concentrations of silver nanoparticles (NAg). METHODS: Various concentrations of NAg (50, 100, 150, 200 and 250 ppm) were incorporated into the primer of the Scotchbond Multi-Purpose adhesive system (SBMP). Antibacterial activity was examined using a broth microdilution assay to determine minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC), agar diffusion assay and the MTT assay was used to examine the biofilm metabolic activity (S. mutans). The Microtensile Bond Test (µTBS) was performed after 24 h, followed by 6-months storage in distilled water. Cytotoxicity was assessed with an MTT reduction assay in human dental pulp stem cells viability after exposure to Nag-conditioned culture media during 0, 24, 48, and 72 h. The results were statistically analyzed (α ≤ 0.05). RESULTS: MIC was found between NAg 25 and 50 ppm MBC was determined at 50 ppm of NAg. Bacterial activity inhibition was higher than control in all NAg groups compared to control in agar diffusion assay. Biofilm inhibition was statistically higher in 250 ppm NAg than control. All NAg groups and SBMP presented similar cytotoxicity in each period. Adhesives with NAg 200 and 250 ppm and SBMP (control) presented the highest µTBS values, similar to that of SBMP control, in both instances (24 h and 6 months) (p > 0.05). CONCLUSIONS: The commercial primer containing NAg 250 ppm showed both antibacterial effect and reliable bond strength with no cytotoxicity increase. The addition of NAg to primers seems promising for the improvement of conventional dental adhesives efficacy. CLINICAL SIGNIFICANCE: The addition of low concentrations of NAg (250 ppm) to primers were effective to improve antibacterial effect preserving the bond strength and the biocompatibility of the commercial product. NAg/primer association could protect the tooth-adhesive interface increasing dental restoration longevity.
Asunto(s)
Antibacterianos/toxicidad , Recubrimiento Dental Adhesivo , Cementos Dentales , Nanopartículas del Metal/toxicidad , Plata , Biopelículas , Humanos , Ensayo de Materiales , Cementos de Resina , Resistencia a la TracciónRESUMEN
AIMS: The purpose of this study was to evaluate the efficacy of orthodontic bonding systems containing different antimicrobial agents, as well as the influence of antimicrobial agent incorporation in the bonding properties of these materials. METHODS: Eight databases were searched: PubMed (Medline), Web of Science, Scopus, Lilacs, Ibecs, BBO, Scielo and Google Scholar. Any study that evaluated antimicrobial activity in experimental or commercial orthodontic bonding systems was included. DATA EXTRACTION: Data were tabulated independently and in duplicated by two authors on pre-designed data collection form. DATA SYNTHESIS: The global analysis was carried out using a random-effects model, and pooled-effect estimates were obtained by comparing the standardised mean difference of each antimicrobial orthodontic adhesive with the respective control group. A p-value < .05 was considered as statistically significant. RESULTS: Thirty-two studies were included in the qualitative analysis; of these, 22 studies were included in the meta-analysis. Antimicrobial agents such as silver nanoparticles, benzalkonium chloride, chlorhexidine, triclosan, cetylpyridinium chloride, Galla chinensis extract, acid ursolic, dimethylaminododecyl methacrylate, dimethylaminohexadecyl methacrylate, 2-methacryloyloxyethyl phosphorylcholine, 1,3,5-triacryloylhexahydro-1,3,5-triazine, zinc oxide and titanium oxide have been incorporated into orthodontic bonding systems. The antimicrobial agent incorporation in orthodontic bonding systems showed higher antimicrobial activity than the control group in agar diffusion (overall standardised mean difference: 3.71; 95% CI 2.98 to 4.43) and optical density tests (0.41; 95% CI -0.05 to 0.86) (p < .05). However, for biofilm, the materials did not present antimicrobial activity (6.78; 95% CI 4.78 to 8.77). Regarding bond strength, the global analysis showed antimicrobial orthodontic bonding systems were statistically similar to the control. CONCLUSIONS: Although there is evidence of antibacterial activity from in vitro studies, clinical and long-term studies are still necessary to confirm the effectiveness of antibacterial orthodontic bonding systems in preventing caries disease.
Asunto(s)
Antiinfecciosos , Recubrimiento Dental Adhesivo , Nanopartículas del Metal , Ensayo de Materiales , Cementos de Resina , PlataRESUMEN
OBJECTIVES: To evaluate the bonding ability and nanoleakage of a universal adhesive applied to dentin pre-treated using a zoledronate-containing primer (zol-primer) before and after mechanical load cycling. MATERIALS AND METHODS: Flat dentin surfaces obtained from human molars were assigned to one of the following adhesion procedures (n=6): 1-Single Bond Universal (SBU) applied in etch-and-rinse mode; 2- SBU applied as etch-and-rinse after the application of zol-primer; 3- SBU applied in self-etch strategy; 4- SBU applied as self-etch after the use of zol-primer. Half of the specimens were processed for microtensile bond strength test after 24h, while the other half part was submitted to 200,000 mechanical cycles. Further specimens were silver-impregnated and assessed for interface nanoleakage by SEM. Data were analyzed with two-way ANOVA and Tukey's test (p<0.05). RESULTS: At 24h evaluation, the four groups presented similar bond strengths, whilst both groups bonded with etch-and-rinse technique showed significant bond strength reduction after mechanical load (p<0.05), with the highest drop in bond strength for the specimens pre-treated with the zol-primer. No negative effects were found for self-etch strategy (p>0.05) in microtensile test. Lower nanoleakage expression was observed for etch-and-rinse specimens treated with zol-primer. However, noteworthy reduction of adhesive layer thickness was observed when combining the zol-primer with the self-etch bonding approach. CONCLUSION: It can be concluded that zol-primer should not be used along with a universal adhesive in etch-and-rinse mode, but its application before self-etch application may provide less degradation of the resin-dentin interface.
Asunto(s)
Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Dentina/química , Difosfonatos/química , Imidazoles/química , Diente Molar/efectos de los fármacos , Cementos de Resina/química , Adhesivos , Bisfenol A Glicidil Metacrilato , Resinas Compuestas/química , Cementos Dentales , Humanos , Ensayo de Materiales , Metacrilatos/química , Plata/química , Propiedades de Superficie , Resistencia a la Tracción , Ácido ZoledrónicoRESUMEN
OBJECTIVES: The purpose of this in vitro study was to evaluate the bonding ability and monomer conversion of a universal adhesive system applied to dentin as functions of different curing times and storage. The results were compared among a variety of commercial adhesives. MATERIALS AND METHODS: Flat superficial dentin surfaces were exposed on human molars and assigned into one of the following adhesives (n = 15): total-etch Adper Single Bond 2 (SB) and Optibond Solo Plus (OS), self-etch Optibond All in One (OA) and Clearfil SE Bond (CSE), and Scotchbond Universal Adhesive in self-etch mode (SU). The adhesives were applied following the manufacturers' instructions and cured for 10, 20, or 40s. Specimens were processed for the microtensile bond strength (µTBS) test in accordance with the non-trimming technique and tested after 24h and 2 years. The fractured specimens were classified under scanning electron microscopy (SEM). Infrared (IR) spectra were obtained and monomer conversion (%) was calculated by comparing the aliphatic-to-aromatic IR absorption peak ratio before and after polymerization (n=5). Data were analyzed by 2-way ANOVA/Tukey's tests (α = 0.05). RESULTS: At 24-h evaluation, OA and CSE presented similar bond strength means irrespective of the curing time, whereas SB and SU exhibited significantly higher means when cured for 40s as did OS when cured for 20 or 40s (p < 0.05). At 2-year evaluation, only OA exhibited significantly higher bond strength when cured for 20 and 40s (p < 0.05). When the evaluation times were compared, OA also exhibited the same bonding ability when cured for longer periods of time (20 and 40s). All of the adhesives tested exhibited significantly lower monomer conversion when photoactivated according to the manufacturers' instructions (10s). CONCLUSIONS: Higher monomer conversions obtained with longer light exposure allow only higher immediate bond strength for most of the adhesives tested. After 2-year storage, only the self-etching adhesive Optibond All-In-One exhibited the same bonding ability when cured for longer periods of time.
Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales , Grabado Ácido Dental , Dentina , Humanos , Resistencia a la TracciónRESUMEN
ABSTRACT Objective To evaluate the influence of phenyl-propanedione on yellowing and chemical-mechanical properties of experimental resin-based materials photoactivated using different light curing units (LCUs). Material and Methods Experimental resin-based materials with the same organic matrix (60:40 wt% BisGMA:TEGDMA) were mechanically blended using a centrifugal mixing device. To this blend, different photoinitiator systems were added in equimolar concentrations with aliphatic amine doubled by wt%: 0.4 wt% CQ; 0.38 wt% PPD; or 0.2 wt% CQ and 0.19 wt% PPD. The degree of conversion (DC), flexural strength (FS), Young’s modulus (YM), Knoop hardness (KNH), crosslinking density (CLD), and yellowing (Y) were evaluated (n=10). All samples were light cured with the following LCUs: a halogen lamp (XL 2500), a monowave LED (Radii), or a polywave LED (Valo) with 16 J/cm2. The results were analysed by two-way ANOVA and Tukey’s test (α=0.05). Results No statistical differences were found between the different photoinitiator systems to KNH, CLS, FS, and YM properties (p≥0.05). PPD/CQ association showed the higher DC values compared with CQ and PPD isolated systems when photoactivated by a polywave LED (p≤0.05). Y values were highest for the CQ compared with the PPD systems (p≤0.05). Conclusion PPD isolated system promoted similar chemical and mechanical properties and less yellowing compared with the CQ isolated system, regardless of the LCU used.