Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Innovations (Phila) ; 19(2): 175-183, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38577864

RESUMEN

OBJECTIVE: We evaluated the effectiveness of a consistent and structured self-practice coronary anastomosis program using a homemade low-fidelity beating-heart simulator. METHODS: An intermediary trainee was subjected to an 8-week structured self-practice program. The program was divided into 2 parts of nonbeating and beating practices with a minimum number of timed anastomoses. Each part was followed by an assessment using an objective skills assessment tool score. The beating-heart simulator was built using motorized toy blocks connected wirelessly to a smartphone application. This was coded to enable rate selection. A junior consultant was compared to the subject at the end of the program. Both were tasked to perform 1 coronary anastomosis for both off-pump coronary artery bypass (OPCAB) and minimally invasive CAB (MICS) setup. The primary outcomes were anastomotic time and score compared with the junior consultant. Secondary outcomes were progression of anastomotic time and score throughout the program. RESULTS: Overall performance of the studied subject approached the performance of the junior consultant in terms of time (OPCAB, 489 vs 605 s; MICS, 712 vs 652 s) and scores (OPCAB, 21 vs 20.7; MICS, 19 vs 20.6). There were inverse correlations between anastomosis time and number of practices for both nonbeating and beating anastomoses. Overall improvement was observed in terms of assessment scoring by 26.6%. CONCLUSIONS: A structured self-practice program using an affordable and accessible simulator was able to help trainees overcome the MICS anastomosis learning curve quicker when introduced earlier. This may encourage earlier adoption of MICS among surgeons.


Asunto(s)
Anastomosis Quirúrgica , Competencia Clínica , Procedimientos Quirúrgicos Mínimamente Invasivos , Humanos , Anastomosis Quirúrgica/educación , Anastomosis Quirúrgica/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/educación , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Puente de Arteria Coronaria Off-Pump/educación , Puente de Arteria Coronaria Off-Pump/métodos , Entrenamiento Simulado/métodos , Vasos Coronarios/cirugía , Prueba de Estudio Conceptual
2.
J Cardiothorac Surg ; 17(1): 315, 2022 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-36527046

RESUMEN

BACKGROUND: Coronary artery bypass graft surgery (CABG) is one of the principle therapies for coronary artery disease, as it improves survival rate and quality of life (QoL). Polypropylene suture is commonly used in vascular and cardiac surgeries for anastomosis due to its long-term tensile strength and minimal tissue trauma. This study compared the clinical equivalence of Trulene® (Healthium Medtech Limited) and Prolene® (Ethicon-Johnson & Johnson) polypropylene sutures regarding incidence of myocardial infarction, stroke, renal failure and cardiac death (MACCE) occurring up to 26 weeks' period post-CABG surgery. METHODS: This multicenter, prospective, two-arm, parallel-group, randomized (1:1), single-blind study (n = 89) was conducted between August 2020 and September 2021. The primary endpoint, post-surgery cumulative incidence of MACCE was evaluated. In addition, anastomotic revision, surgical site infection (SSI), operative time, length of post-operative hospital stay, repeat revascularization, intraoperative suture handling characteristics, time taken to return to work and resume normal day to day activities, subject satisfaction score and QoL, and other adverse events were also recorded. RESULTS: A total of 80 (89.89%) males and 9 (10.11%) females participated in the study. No incidence of MACCE was recorded in any of the study participants. Non-significant difference was observed in anastomotic revision, SSI, operative time, post-operative hospital stay, revascularization, return to work and normal day-to-day activities, subject satisfaction score and QoL, and intraoperative handling parameters (except ease of passage) between the treatment groups, Trulene® and Prolene®. Compared to screening visit, proportion of subjects with 'no problems' for each QoL dimension and the mean visual analogue scale increased with each subsequent follow-up visit. CONCLUSION: Trulene® polypropylene suture is clinically equivalent to Prolene® polypropylene suture and is safe and effective for anastomosis construction in CABG surgery during a routine clinical procedure. Trial registration CTRI Registration No.: CTRI/2020/05/025157 (Registered on: 13/05/2020).


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Masculino , Femenino , Humanos , Polipropilenos , Método Simple Ciego , Calidad de Vida , Estudios Prospectivos , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Suturas , Infección de la Herida Quirúrgica , Resultado del Tratamiento
3.
Asian Cardiovasc Thorac Ann ; 30(6): 661-668, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34757850

RESUMEN

BACKGROUND: We sought to evaluate our distributed practice program developed for training for beating heart anastomosis by employing a novel beating heart simulator. METHODS: Eleven trainees watched and reviewed instructional video recordings of coronary anastomosis methods with a BEAT + YOUCAN training device, then performed coronary anastomosis procedures under a beating condition. Next, they participated in a four-hour training program developed by faculty surgeons. Ten different anastomosis components were assessed on a five-point rating scale (5, good; 3, average; 1, poor). After finishing the training program, each trainee again performed a coronary anastomosis procedure. Component scores were then compared before and after the training program. RESULTS: The mean time to completion of the procedure improved from 1033 ± 424 to 795 ± 201 s (p < 0.05). Assessment scores improved from 1.88 ± 0.41 to 2.57 ± 0.30 (p < 0.05). Improvements in some technical components related to handling of instruments were noted (p < 0.05), whereas no significant improvement was seen with arteriotomy, graft orientation, suture management, or knot tying after finishing the training program. CONCLUSION: Trainees who participated in our four-hour focused training program for coronary anastomosis with a novel beating heart simulator showed improved ability under the beating condition in regard to technical skills related to handling instruments.


Asunto(s)
Internado y Residencia , Entrenamiento Simulado , Procedimientos Quirúrgicos Torácicos , Anastomosis Quirúrgica , Competencia Clínica , Humanos , Resultado del Tratamiento
4.
J Cardiothorac Surg ; 15(1): 3, 2020 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-31915030

RESUMEN

BACKGROUND: Widespread use of intraoperative epicardial ultrasonography (ECUS) for quality assessment of coronary artery bypass graft anastomoses during coronary artery bypass grafting (CABG) has not occurred - presumably due to technological and practical challenges including the need to maintain stable and optimal acoustic contact between the ultrasound probe and the target without the risk of distorting the anastomosis. We investigated the feasibility of using a stabilizing device during ultrasound imaging of distal coronary bypass graft anastomoses in patients undergoing on-pump CABG. Imaging was performed in both the longitudinal and transverse planes. METHODS: Single-centre, observational prospective feasibility study among 51 patients undergoing elective, isolated on-pump CABG. Ultrasonography of peripheral coronary bypass anastomoses was performed using a stabilizing device upon which the ultrasound transducer was connected. Transit-time flow measurement (TTFM) was also performed. Descriptive statistical tests were used. RESULTS: Longitudinal and transverse images from the heel, middle and toe were obtained from 134 of 155 coronary anastomoses (86.5%). After the learning curve (15 patients), all six projections were obtained from 100 of 108 anastomoses scanned (93%). Failure to obtain images were typical due to a sequential curved graft with anastomoses that could not be contained in the straight cavity of the stabilizing device, echo artefacts from a Titanium clip located in the roof of the anastomoses, and challenges in interpreting the images during the learning curve. No complications were associated with the ECUS procedure. The combined ECUS and TTFM resulted in immediate revision of five peripheral anastomoses. CONCLUSIONS: Peroperative use of a stabilizing device during ultrasonography of coronary artery bypass anastomoses in on-pump surgery facilitates imaging and provides surgeons with non-deformed longitudinal and transverse images of all parts of the anastomoses in all coronary territories. Peroperative ECUS in addition to flow measurements has the potential to increase the likelihood of detecting technical errors in constructed anastomoses. TRIAL REGISTRATION: The study was registered on September 29, 2016, ClinicalTrials.gov ID: NCT02919124.


Asunto(s)
Puente de Arteria Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Ultrasonografía Intervencional/instrumentación , Anciano , Anastomosis Quirúrgica , Estudios de Factibilidad , Femenino , Humanos , Periodo Intraoperatorio , Masculino , Persona de Mediana Edad , Estudios Prospectivos
5.
J Cardiothorac Surg ; 14(1): 59, 2019 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-30866994

RESUMEN

BACKGROUND: Intraoperative epicardial ultrasonography of coronary artery bypass graft anastomoses is a procedure used for anatomical quality assessment of peripheral anastomoses during coronary artery bypass grafting. However, it may be difficult to keep the ultrasound transducer in steady contact with the anastomoses on the beating heart without causing any deformation. Furthermore, we are not aware of any sterile ultrasound gel approved for application into the pericardial space. CASE PRESENTATION: We report a method using a stabilizing connecting device for an ultrasound transducer to be used for visualization of coronary anastomoses without application of ultrasound gel during on-pump coronary bypass surgery. CONCLUSION: Use of a stabilizing device and coagulated blood from the patient as an alternative for ultrasound gel facilitates peroperative ultrasonography of coronary anastomoses. The procedure provides surgeons with non-deformed echocardiographic longitudinal and transverse images of all parts of the anastomoses. TRIAL REGISTRATION: The patient participated in a still ongoing clinical feasibility study: Trial registration: ClinicalTrials.gov ID: NCT02919124 ; Registered September 29, 2016.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía/instrumentación , Pericardio/diagnóstico por imagen , Anastomosis Quirúrgica , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Geles , Humanos , Cuidados Intraoperatorios , Masculino , Persona de Mediana Edad
6.
Int Heart J ; 59(4): 848-853, 2018 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-29794384

RESUMEN

The Bentall procedure is a surgical technique for an ascending aortic or aortic aneurysm in combination with valve disease. A well-known uncommon complication of after the Bentall procedure is coronary artery stenosis related to coronary anastomosis of an interposed graft. We report on a 73-year-old woman who presented with heart failure secondary to graft stenosis of the right coronary artery 6 months after undergoing a modified Bentall procedure. Percutaneous coronary intervention (PCI) was performed and type II coronary artery perforation occurred during PCI of the right coronary artery. We used a perfusion balloon and achieved hemostasis successfully. We report a case of coronary artery perforation that was treated with perfusion balloon during PCI in a patient with a prior modified Bentall procedure. In addition, we present a case series of PCI for ostial coronary stenosis after the Bentall procedure.


Asunto(s)
Estenosis Coronaria , Vasos Coronarios/lesiones , Complicaciones Intraoperatorias , Intervención Coronaria Percutánea/efectos adversos , Complicaciones Posoperatorias , Injerto Vascular , Anciano , Aorta/cirugía , Aneurisma de la Aorta/cirugía , Válvula Aórtica/cirugía , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/etiología , Femenino , Hemostasis Quirúrgica/métodos , Humanos , Complicaciones Intraoperatorias/diagnóstico , Complicaciones Intraoperatorias/etiología , Intervención Coronaria Percutánea/métodos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/cirugía , Resultado del Tratamiento , Injerto Vascular/efectos adversos , Injerto Vascular/métodos
7.
Clin Anat ; 29(3): 371-9, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25255889

RESUMEN

Coronary arteries have been extensively described and recognized by gross anatomic studies. However, in the clinical setting, the recognition of the conal artery is essential during coronary angiography, as well as certain congenital heart conditions such as tetralogy of Fallot. In order to provide a complete anatomic and physiologic correlation of the actual incidence and distribution of the conal artery we examined 300 formalin fixed hearts with gross dissections and 300 coronary angiograms. The conal artery was identified in all hearts examined and five main patterns were recognized. In Type A (193, 32.1%), the conal artery arose as a branch of the right coronary artery (RCA); in Type B (96, 16%), the conal artery arose from the common coronary ostium with the RCA; in Type C (242, 40.3%), the conal artery took origin from the right aortic sinus as an independent artery; in Type D (48, 8%), multiple conal arteries were present and arose from the RCA as separate branches (32, 66.6%), from a common ostium with the RCA (8, 16.6%) or from the aortic sinus (8, 16.6%); in Type E (22, 3.6%), the conal artery arose as a branch of the right ventricular branch (17, 2.8%) or acute marginal artery (5, 0.8%). The relative prevalence of the five patterns as well as the morphology and the topography of the conal artery varied significantly with the degree of coronary luminal stenosis (as observed during angiography) and also with the degree of hypertrophied ventricular wall (as observed during gross dissections).


Asunto(s)
Vasos Coronarios/anatomía & histología , Anciano , Anciano de 80 o más Años , Variación Anatómica , Femenino , Humanos , Masculino , Persona de Mediana Edad
8.
Interact Cardiovasc Thorac Surg ; 16(6): 772-6, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23456683

RESUMEN

OBJECTIVES: Gaining cardiac surgical competence is a complex, multifactorial process that may take years of experience and on-the-job training. It is critical to provide suitable educational opportunities to gain the necessary knowledge, judgment and skills. In response to the multitude of factors (e.g. European Working Time Directive) currently influencing cardiac surgical training, there have been concerted efforts to reform training practices. Simulation plays an increasingly important role in the educational process and serves to fill the most important gap in the current training model, i.e. operative exposure. Therefore, a contest has been written out for cardiac surgical trainees to construct their own coronary anastomosis simulator using everyday materials. METHODS: Cardiac surgical trainees were invited to construct their own coronary anastomosis simulator. An international jury of cardiac surgeons assessed the simulator and its presentation according to preset developmental criteria (low fidelity concept, innovative character, general presentation and description, general attractiveness to the scholar, ergonomical issues, perceived haptics, number of applicable components, transportability, ease of construction, repeatability and overall costs of the simulator). RESULTS: Six prototypes of simulators built by cardiac surgical trainees were generated. A general evaluation of each simulator prototype is provided according to the preset developmental criteria. CONCLUSIONS: All simulator prototypes have provided a considerable contribution to the field of surgical simulation. By designing simulator prototypes, the trainees have demonstrated their 'out of the box' thinking capability, which is of paramount importance for the development of future innovative surgical techniques and procedures. The Valladolid cardiac team coronary anastomosis simulator box was selected for the EACTS Ethicon Simulation Award 2011. This project will be mass produced and distributed to the participants of structured simulation sessions for coronary anastomoses.


Asunto(s)
Puente de Arteria Coronaria/educación , Vasos Coronarios/cirugía , Educación de Postgrado en Medicina/métodos , Modelos Anatómicos , Modelos Cardiovasculares , Anastomosis Quirúrgica , Distinciones y Premios , Competencia Clínica , Conducta Competitiva , Humanos , Curva de Aprendizaje , Destreza Motora
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA