Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 161
Filtrar
1.
Front Ophthalmol (Lausanne) ; 4: 1380701, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38984114

RESUMEN

Introduction: The application of artificial intelligence (AI) systems in ophthalmology is rapidly expanding. Early detection and management of keratoconus is important for preventing disease progression and the need for corneal transplant. We review studies regarding the utility of AI in the diagnosis and management of keratoconus and other corneal ectasias. Methods: We conducted a systematic search for relevant original, English-language research studies in the PubMed, Web of Science, Embase, and Cochrane databases from inception to October 31, 2023, using a combination of the following keywords: artificial intelligence, deep learning, machine learning, keratoconus, and corneal ectasia. Case reports, literature reviews, conference proceedings, and editorials were excluded. We extracted the following data from each eligible study: type of AI, input used for training, output, ground truth or reference, dataset size, availability of algorithm/model, availability of dataset, and major study findings. Results: Ninety-three original research studies were included in this review, with the date of publication ranging from 1994 to 2023. The majority of studies were regarding the use of AI in detecting keratoconus or subclinical keratoconus (n=61). Among studies regarding keratoconus diagnosis, the most common inputs were corneal topography, Scheimpflug-based corneal tomography, and anterior segment-optical coherence tomography. This review also summarized 16 original research studies regarding AI-based assessment of severity and clinical features, 7 studies regarding the prediction of disease progression, and 6 studies regarding the characterization of treatment response. There were only three studies regarding the use of AI in identifying susceptibility genes involved in the etiology and pathogenesis of keratoconus. Discussion: Algorithms trained on Scheimpflug-based tomography seem promising tools for the early diagnosis of keratoconus that can be particularly applied in low-resource communities. Future studies could investigate the application of AI models trained on multimodal patient information for staging keratoconus severity and tracking disease progression.

2.
Cureus ; 16(5): e60277, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38872649

RESUMEN

The purpose of this clinical report is to describe a 10-year clinical outcome of advanced surface ablation with photorefractive keratectomy (PRK) in a patient who had been previously incorrectly diagnosed with keratoconus (KC). Corneal ectasia is a rare but extremely relevant complication of laser vision correction, and KC represents a major contraindication for these procedures. Nonetheless, some surface ablation procedures, such as PRK, might be a valid option for particular patients with atypical corneal topography or subclinical or mild forms of KC. Patient education and complete preoperative refractive multimodal imaging are essential for a more conscious therapeutic decision, minimizing iatrogenic ectasia, as well as decreasing the number of patients who are incorrectly denied refractive surgery, as was the patient presented in this study.

3.
Cureus ; 16(5): e59431, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38826919

RESUMEN

Scleroderma is an autoimmune disease that affects connective tissue. Keratoconus (KC) is a rare ocular condition that may appear alongside scleroderma. Contact lenses are an essential visual aid for KC patients, especially in advanced cases. However, scleroderma patients may face difficulties using them due to finger-related disabilities. Corneal collagen cross-linking (CXL) is a crucial treatment used to prevent corneal thinning and visual deterioration in progressive KC. However, the potential trigger of corneal melt and delayed healing following CXL in KC patients with scleroderma is a matter of concern. We present a case of a patient with KC and scleroderma who underwent CXL without any complications.

4.
Clin Exp Ophthalmol ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38938058

RESUMEN

BACKGROUND: To evaluate the results of corneal allogenic intrastromal ring segment (CAIRS) implantation in keratoconus. METHODS: The medical records of patients with keratoconus who underwent CAIRS implantation were reviewed. The CAIRS, prepared by trephination from the donor cornea, was implanted into a tunnel created using the femtosecond laser. The depth of the tunnel was 200 µ; the inner diameter of the tunnel was 4.5 mm; and the outer diameter was 7 mm. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), keratometry, minimum corneal thickness (CT), endothelial cell density (ECD), and high order aberration values were recorded preoperatively and at the 1st, 3rd, and 6th months postoperatively. RESULTS: A total of 23 eyes of 23 patients were included in the study. Preoperative UCVA (0.08 ± 0.01) and BCVA (0.25 ± 0. 11) values improved postoperatively and reached 0.40 ± 0.05 and 0.68 ± 0.09, respectively, at the end of the 6-month follow-up period (p1 < 0.001, p2 = 0.016; respectively). A statistically significant flattening of all keratometric values was observed in the postoperative period compared to preoperatively (p < 0.001 for all). There were no statistical differences between CT and ECC values at the preoperative and postoperative visits (p1 = 0.654, p2 = 0.769; respectively). In addition, coma aberration values were lower than the preoperative values at all postoperative visits (p < 0.05 for all). CONCLUSIONS: These results suggest that CAIRS implantation is a safe treatment option with good visual and keratometric outcomes for suitable patients with keratoconus.

6.
Int J Ophthalmol ; 17(3): 491-498, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38721519

RESUMEN

AIM: To study the changes and effect factors of posterior corneal surface after small incision lenticule extraction (SMILE) with different myopic diopters. METHODS: Ninety eyes of 90 patients who underwent SMILE were included in this retrospective study. Patients were allocated into three groups based on the preoperative spherical equivalent (SE): low myopia (SE≥-3.00 D), moderate myopia (-3.00 D>SE>-6.00 D) and high myopia (SE≤-6.00 D). Posterior corneal surfaces were measured by a Scheimpflug camera preoperatively and different postoperative times (1wk, 1, 3, 6mo, and 1y). Posterior mean elevation (PME) at 25 predetermined points of 3 concentric circles (2-, 4-, and 6-mm diameter) above the best fit sphere was analyzed. RESULTS: All surgeries were completed uneventfully and no ectasia was found through the observation. The difference of myopia group was significant at the 2-mm ring at 1 and 3mo postoperatively (1mo: P=0.017; 3mo: P=0.018). The effect of time on ΔPME was statistically significant (2-mm ring: P=0.001; 4-mm ring: P<0.001; 6-mm ring: P<0.001). The effect of different corneal locations on ΔPME was significant except 1wk postoperatively (1mo: P=0.000; 3mo: P=0.000; 6mo: P=0.001; 1y: P=0.001). Posterior corneal stability was linearly correlated with SE, central corneal thickness, ablation depth, residual bed thickness, percent ablation depth and percent stromal bed thickness. CONCLUSION: The posterior corneal surface changes dynamically after SMILE. No protrusion is observed on the posterior corneal surface in patients with different degrees of myopia within one year after surgery. SMILE has good stability, accuracy, safety and predictability.

7.
Int J Ophthalmol ; 17(3): 596-602, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38721520

RESUMEN

AIM: To explore the clinical efficacy and safety of stromal lenticule addition keratoplasty (SLAK) with corneal crosslinking (CXL) on patients with corneal ectasia secondary to femtosecond laser-assisted in situ keratomileusis (FS-LASIK). METHODS: A series of 5 patients undertaking SLAK with CXL for the treatment of corneal ectasia secondary to FS-LASIK were followed for 4-9mo. The lenticules were collected from patients undertaking small incision lenticule extraction (SMILE) for the correction of myopia. Adding a stromal lenticule was aimed at improving the corneal thickness for the safe application of crosslinking and compensating for the thin cornea to improve its mechanical strength. RESULTS: All surgeries were conducted successfully with no significant complications. Their best corrected visual acuity (BCVA) ranged from 0.05 to 0.8-2 before surgery. The pre-operational total corneal thickness ranged from 345-404 µm and maximum keratometry (Kmax) ranged from 50.8 to 86.3. After the combination surgery, both the corneal keratometry (range 55.9 to 92.8) and total corneal thickness (range 413-482 µm) significantly increased. Four out of 5 patients had improvement of corneal biomechanical parameters (reflected by stiffness parameter A1 in Corvis ST). However, 3 patients showed decreased BCVA after surgery due to the development of irregular astigmatism and transient haze. Despite the onset of corneal edema right after SLAK, the corneal topography and thickness generally stabilized after 3mo. CONCLUSION: SLAK with CXL is a potentially beneficial and safe therapy for advanced corneal ectasia. Future work needs to address the poor predictability of corneal refractometry and compare the outcomes of different surgical modes.

8.
Cells ; 13(7)2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38607065

RESUMEN

(1) Background: Our previous data indicated that disturbance of the Transforming Growth Factor beta (TGFB) signaling pathway via its Type-2 Receptor (TGFBR2) can cause a Corneal Ectasia (CE)-like phenotype. The purpose of this study is to elucidate whether the SMAD4-dependent signaling pathway is involved in the TGFBR2-related CE-like pathogenesis. (2) Methods: Smad4 was designed to be conditionally knocked out from keratocytes. Novel triple transgenic mice, KerartTA; Tet-O-Cre; Smad4flox/flox (Smad4kera-cko), were administered with doxycycline (Dox). Optical Coherence Tomography (OCT) was performed to examine Central Corneal Thickness (CCT), Corneal Radius, Anterior Chamber and CE-like phenotype and compared to the littermate Control group (Smad4Ctrl). (3) Results: The OCT revealed normal cornea in the Smad4Ctrl and a CE-like phenotype in the Smad4kera-cko cornea, in which the overall CCT in Smad4kera-cko was thinner than that of Smad4Ctrl at P42 (n = 6, p < 0.0001) and showed no significant difference when compared to that in Tgfbr2kera-cko. Furthermore, the measurements of the Anterior Chamber and Corneal Radius indicated a substantial ectatic cornea in the Smad4kera-cko compared to Smad4Ctrl. The H&E staining of Smad4kera-cko mimics the finding in the Tgfbr2kera-cko. The positive immunostaining of cornea-specific marker K12 indicating the cell fate of cornea epithelium remained unchanged in Smad4kera-cko and the Proliferating Cell Nuclear Antigen (PCNA) immunostaining further indicated an enhanced proliferation in the Smad4kera-cko. Both immunostainings recapitulated the finding in Tgfbr2kera-cko. The Masson's Trichrome staining revealed decreased collagen formation in the corneal stroma from both Smad4kera-cko and Tgfbr2kera-cko. The collagen type 1 (Col1a1) immunostaining further confirmed the reduction in collagen type 1 formation in Smad4kera-cko. (4) Conclusions: The aforementioned phenotypes in the Smad4kera-cko strain indicated that the SMAD4-dependent signaling pathway is involved in the pathogenesis of the CE-like phenotype observed in Tgfbr2kera-cko.


Asunto(s)
Enfermedades de la Córnea , Ratones , Animales , Receptor Tipo II de Factor de Crecimiento Transformador beta/genética , Enfermedades de la Córnea/patología , Ratones Transgénicos , Transducción de Señal , Fenotipo , Colágeno
9.
J Clin Med ; 13(8)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38673651

RESUMEN

Background: Scheimpflug tomography has for many years been an integral part of our pre-operative assessment in cataract extraction. We retrospectively reviewed the incidence of topographic keratoconus and keratoconus suspicion in our routine cataract surgery population over 5 years. Setting: The Laservision Clinical and Research Institute, Athens, Greece. Methods: In 1250 consecutive cataract surgery cases in otherwise naïve eyes, accounting for years 2017 to 2021, we retrospectively evaluated preoperative Pentacam HR imaging. The cases already classified as keratoconus were included in group A. The residual cases were assessed by five different experienced evaluators (two ophthalmic surgeons and three optometrists) for topographic and tomographic keratoconus suspicion based on irregular pachymetry distribution, astigmatism truncation, and/or astigmatic imaging irregularity and included in group B. Regular corneas, by this assessment, were included in group C; irregular corneas, as determined by the evaluators but unrelated to keratoconus, were included in group D. Results: Based on the above, 138 cases (11.08%) were classified by Pentacam tomography as keratoconus and by default were included in group A. Of the residual cases, 314 or 25.12% were classified as suspect keratoconus and included in group B; 725 cases (58%) were classified as normal and non-keratoconus and included in group C; and 73 cases or 5.84% were placed in group D as non-keratoconus but abnormal. There was no disagreement between the five evaluators over any of the cases in groups C and D, and little variance among them for cases included in group B (less than 5% by ANOVA). Conclusions: The incidence of keratoconus and corneas suspicious for keratoconus in Greece appears to be much higher than respective reports from other regions: one in ten Greeks appear to have topographic keratoconus, most not diagnosed even by the age of cataract surgery, and almost an additional one in four may have suspicious corneal imaging for keratoconus. These data strongly imply that routine screening for disease should be promoted among Greeks, especially during puberty, to halt possible progression; moreover, careful screening should be performed when laser vision correction is being considered.

10.
Clin Ophthalmol ; 18: 865-879, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38525385

RESUMEN

Introduction: Corneal ectasia leads to progressive irregular corneal curvature and reduced visual acuity. Objective: To assess the safety and effectiveness of corneal collagen cross-linking (CXL) for managing corneal ectasia resulting from refractive laser surgery (RSL). Methods: A systematic review and meta-analysis were realized according to PRISMA guidelines. We searched PubMed, EMBASE, Cochrane, and Web of Science databases for studies on CXL in patients with ectasia after RLS. The outcomes of interest included visual acuity, refractive outcomes, topographic parameters (Kmax, index surface variance (ISV), index of Vertical Asymmetry (IVA), keratoconus index (KI), central keratoconus index (CKI), index of height asymmetry (IHA), index of height decentration (IHD) and Rmin (minimum sagittal curvature)), central corneal thickness, endothelial cell count, and possible adverse events. Statistical analysis was performed using the R software (version 4.2.3, R Foundation for Statistical Computing, Vienna, Austria). Results: 15 studies encompassing 421 patients (512 eyes) were included. The mean age was 32.03 ± 4.4 years. The pooled results showed a stable uncorrected visual acuity post-CXL, with a significant improvement in corrected distance visual acuity (SMD = 0.09; 95% CI: -0.07 to 0.26). The spherical equivalent decreased significantly (SMD = -0.09; 95% CI: -0.35, -0.02). The topographic parameter Kmax decreased significantly (SMD = 0.15; 95% CI:0.01 to 0.28); however, the other parameters, ISV, IVA, KI, CKI, IHA, IHD, and Rmin, did not change significantly. Central corneal thickness decreased significantly (SMD = 0.24; 95% CI:0.07 to 0.41), and the endothelial cell count remained stable The complications were rare. Conclusion: CXL is a safe and effective technique for managing corneal ectasia after RLS.

11.
Case Rep Ophthalmol ; 15(1): 189-195, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38464399

RESUMEN

Introduction: We present a case of a patient with osteogenesis imperfecta (OI) and keratoglobus (KG) who had a near-total rupture of Descemet's membrane followed by spontaneous corneal clearing. This case is unique in that it demonstrates the potentially excellent outcome of conservative treatment for Descemet's rupture in patients with KG and illustrates the impressive migratory potential of healthy endothelial cells. Case Presentation: An 11-year-old girl with OI and KG who had rupture and near-total detachment of Descemet's membrane presented for evaluation. This was managed conservatively and resulted in the eventual spontaneous clearing of the cornea. A similar process happened in the fellow eye some years later. Given the result of conservative management originally, the patient was once again treated conservatively, with significant improvement in corneal edema and visual acuity. Conclusion: Given the size of the ruptures, this case highlights the dynamic nature of the corneal endothelium and provides an extreme example of the migratory potential of corneal endothelial cells.

12.
Int Ophthalmol ; 44(1): 145, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38498219

RESUMEN

PURPOSE: To compare the visual, refractive, and topographic outcomes of a high irradiance accelerated corneal crosslinking (ACXL) protocol after a 12-month follow-up between pediatric and adult patients with progressive keratoconus (KC). METHODS: Retrospective, comparative, cohort study. Patients with KC were divided into two groups: pediatric (≤ 18 years) and adult (> 18 years). All of them were managed with epi-OFF ACXL (30 mW/cm2, 8 min, pulsed 1:1 on and off = 7.2 J/cm2). Visual, refractive, and topographic values were measured preoperatively and at 1, 3, 6, and 12 months postoperative. KC progression, defined as a Kmax increase of ≥ 1D during follow-up, was recorded. RESULTS: Eighty-nine eyes (53 patients) were included for analysis; 45 (50.6%) eyes were from pediatric patients and 44 (49.4%) from adults. At one-year follow-up, pediatric patients experienced significantly higher rates of progression (22.2% vs. 4.5%, p = .014). Contrariwise, female gender (Beta = - 3.62, p = .018), a baseline uncorrected visual acuity of Snellen ≥ 20/60 (Beta = - 5.96, p = .007), and being ≥ 15 years at ACXL treatment (Beta = - 0.31, p = .021) were associated with non-progressive disease. A significant improvement in best-corrected visual acuity, Kmin, Km, and Kmax was recorded in both groups. Overall, 86.5% of eyes from both groups showed Kmax stabilization or improvement. CONCLUSIONS: Despite the similarity in visual, refractive, and topographic outcomes in both groups, younger age was associated with KC progression after ACXL at one year of follow-up.


Asunto(s)
Queratocono , Fotoquimioterapia , Adulto , Humanos , Femenino , Niño , Queratocono/diagnóstico , Queratocono/tratamiento farmacológico , Fármacos Fotosensibilizantes/uso terapéutico , Fotoquimioterapia/métodos , Reticulación Corneal , Estudios Retrospectivos , Estudios de Cohortes , Riboflavina/uso terapéutico , Rayos Ultravioleta , Topografía de la Córnea/métodos , Estudios de Seguimiento , Reactivos de Enlaces Cruzados/uso terapéutico , Colágeno/uso terapéutico
13.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(1): 129-135, 2024 Feb 25.
Artículo en Chino | MEDLINE | ID: mdl-38403613

RESUMEN

The mechanical properties of the cornea in corneal ectasia disease undergo a significant reduction, yet the alterations in mechanical properties within distinct corneal regions remain unclear. In this study, we established a rabbit corneal ectasia model by employing collagenase II to degrade the corneal matrix within a central diameter of 6 mm. Optical coherence tomography was employed for the in vivo assessment of corneal morphology (corneal thickness and corneal curvature) one month after operation. Anisotropy and viscoelastic characteristics of corneal tissue were evaluated through biaxial and uniaxial testing, respectively. The results demonstrated a marked decrease in central corneal thickness, with no significant changes observed in corneal curvature. Under different strains, the elastic modulus of the cornea exhibited no significant differences in the up-down and naso-temporal directions between the control and model groups. However, the cornea in the model group displayed a significantly lower elastic modulus compared to the control group. Specifically, the elastic modulus of the central region cornea in the model group was significantly lower than that of the entire cornea within the same group. Moreover, in comparison to the control group, the cornea in the model group exhibited a significant increase in both creep rate and overall deformation rate. The instantaneous modulus and equilibrium modulus were significantly reduced in the model cornea. No significant differences were observed between the entire cornea and the central cornea concerning these parameters. The results indicate that corneal anisotropy remains unchanged in collagenase-induced ectatic cornea. However, a significant reduction in viscoelastic properties is noticed. This study provides valuable insights for investigating changes in corneal mechanical properties within different regions of ectatic corneal disease.


Asunto(s)
Córnea , Enfermedades de la Córnea , Animales , Conejos , Dilatación Patológica , Anisotropía , Colagenasas
14.
Eye Vis (Lond) ; 11(1): 2, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38167119

RESUMEN

BACKGROUND: Keratoconus is characterized by asymmetry in the biomechanical properties of the cornea, with focal weakness in the area of cone formation. We tested the hypothesis that centrally-measured biomechanical parameters differ between corneas with peripheral cones and corneas with central cones. METHODS: Fifty participants with keratoconus were prospectively recruited. The mean ± standard deviation age was 38 ± 13 years. Axial and tangential corneal topography were analyzed in both eyes, if eligible. Cones in the central 3 mm of the cornea were considered central, and cones outside the central 3 mm were considered peripheral. Each eye was then measured with the Ocular Response Analyzer (ORA) tonometer. T-tests compared differences in ORA-generated waveform parameters between cohorts. RESULTS: Seventy-eight eyes were analyzed. According to the axial topography maps, 37 eyes had central cones and 41 eyes had peripheral cones. According to the tangential topography maps, 53 eyes had central cones, and 25 eyes had peripheral cones. For the axial-topography algorithm, wave score (WS) was significantly higher in peripheral cones than central cones (inter-cohort difference = 1.27 ± 1.87). Peripheral cones had a significantly higher area of first peak, p1area (1047 ± 1346), area of second peak, p2area (1130 ± 1478), height of first peak, h1 (102 ± 147), and height of second peak, h2 (102 ± 127), than central cones. Corneal hysteresis (CH), width of the first peak, w1, and width of the second peak, w2, did not significantly differ between cohorts. There were similar results for the tangential-topography algorithm, with a significant difference between the cohorts for p1area (855 ± 1389), p2area (860 ± 1531), h1 (81.7 ± 151), and h2 (92.1 ± 131). CONCLUSIONS: Cone location affects the biomechanical response parameters measured under central loading of the cornea. The ORA delivers its air puff to the central cornea, so the fact that h1 and h2 and that p1area and p2area were smaller in the central cone cohort than in the peripheral cone cohort suggests that corneas with central cones are softer or more compliant centrally than corneas with peripheral cones, which is consistent with the location of the pathology. This result is evidence that corneal weakening in keratoconus is focal in nature and is consistent with localized disruption of lamellar orientation.

15.
Comput Biol Med ; 170: 107870, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38217971

RESUMEN

A biomechanical model that simulates the physiological pressure load on the cornea without considering the stresses in vivo will result in an overstress or underestimation of the stress field and incorrect deformation of the corneal structure. Therefore, it is essential to propose numerical models that consider the stress-free geometry of the cornea. In this study, the Displacement and Pre-stress methods were compared to obtain the stress-free geometry (S-FG) and the physiological estimated geometry (P-EG), based on the patient-specific geometric behavior and the computational time required to reach each geometry. The same shape and contour conditions were considered in the models obtained from both methods for each of the pathological scenarios analyzed. Both methods behaved differently to obtain the free geometry, and this difference increased with the severity grade of the disease. However, they behaved in a similar way to reach the physiological estimated geometry. The Displacement method required a lower computational cost to reach the free geometry, with both methods presenting a similar computational cost to obtain the physiological geometry. The stress-free geometries obtained by both methods allowed to characterize the existing biomechanical decompensation during the progression of the diseases. In conclusion, the calculation of the stress-free corneal geometry associated to the clinically measured intraocular pressure with the Displacement and Prestress Methods in keratoconus eyes allows the development of accurate and useable models in clinical practice in real time. This displacement method shows some benefits in terms of computational cost.


Asunto(s)
Queratocono , Humanos , Fenómenos Biomecánicos , Córnea , Tonometría Ocular , Presión Intraocular
16.
Graefes Arch Clin Exp Ophthalmol ; 262(3): 879-889, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37682334

RESUMEN

PURPOSE: To provide insights into morphologic and functional features of eyes with complicated Descemet's membrane detachment (DMD) and report clinical outcomes after surgical intervention. METHODS: Retrospective study of 18 eyes with complicated DMD between 2010 and 2022. Complicated DMD was defined if any of the following criteria applied: prior penetrating keratoplasty (PKP), corneal thinning, total DMD or persistent DMD after Air/Gas-Descemetopexy. Causes, surgical management, and clinical outcomes were analyzed. Scheimpflug tomography, anterior segment optical coherence tomography (AS-OCT) and histologic examination were performed to characterize corneas with DMD. RESULTS: Fourteen eyes with prior PKP developed spontaneous DMD after 24.2 ± 12.9 years (range = 18 months - 47 years, median = 25.7 years). Complicated DMD without prior PKP was associated in three eyes after cataract surgery and in one eye after infectious keratitis. In cases with previous PKP, AS-OCT demonstrated rupture of Descemet's membrane (DM) in five eyes and spontaneous reattachment was found in four eyes within 8 weeks of initial diagnosis, with no rupture of DM in any of the cases. There was no rupture of DM in corneas without previous PKP. After prior keratoplasty, definitive surgical treatment was repeat PKP in 13 eyes and Air/Gas-Descemetopexy in one eye. In corneas without prior keratoplasty, three eyes underwent PKP and one eye Air/Gas-Descemetopexy. Histological examination of two corneal explants revealed a severely thinned graft-host junction and a disrupted DM close to the graft-host junction. Visual acuity improved from 1.80 ± 0.58 logMAR to 0.75 ± 0.69 logMAR after prior PKP and from 1.45 ± 0.65 logMAR to 0.85 ± 1.13 logMAR without prior PKP. The postoperative course was uneventful in 16 of 18 eyes. CONCLUSION: PKP is an effective treatment option for complicated DMD, especially in ectatic corneas, whereas Air/Gas-Descemetopexy or Descemet Membrane Endothelial Keratoplasty do not address the primary issue of the curvature anomaly.


Asunto(s)
Trasplante de Córnea , Lámina Limitante Posterior , Humanos , Lámina Limitante Posterior/cirugía , Estudios Retrospectivos , Córnea , Queratoplastia Penetrante
17.
Cont Lens Anterior Eye ; 47(1): 102100, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38072740

RESUMEN

PURPOSE: To investigate the alterations in corneal biomechanical metrics induced by orthokeratology (ortho-k) using Corvis ST and to determine the factors influencing these changes. METHOD: A prospective observational study was conducted to analyze various Corvis ST parameters in 32 children with low to moderate myopia who successfully underwent ortho-k lens fitting. Corneal biomechanical measurements via Corvis ST were acquired at six distinct time points: baseline (pre) and 2 h (pos2h), 6 h (pos6h), and 10 h (pos10h) following the removal of the first overnight wear ortho-k, one week (pos1w) and one month (pos1m) subsequent to the initiation of ortho-k. RESULT: Significant differences were observed in Corvis ST Biomechanical parameters DAR2, IIR, CBI, and cCBI post ortho-k intervention. The integration of covariates (CCT, SimK, and bIOP) mitigated the differences in DAR2, IIR, and cCBI, but not in CBI. Initially, the stiffness parameter at first applanation, SP-A1, did not demonstrate significant variations, but after adjusting for covariates, noticeable differences over time were observed. The Stress-Strain Indeces, SSIv1 and SSIv2, did not manifest considerable changes over time, irrespective of the adjustment for covariates. No significant disparities were identified among different ortho-k lens brands. CONCLUSION: Corneal biomechanics remained consistent throughout the one-month period of ortho-k lens wear. The observed changes in Corvis ST parameters subsequent ortho-k are primarily attributable to alterations in corneal pachymetry and morphology, rather than actual alterations in corneal biomechanics. The stability of corneal biomechanics post ortho-k treatment suggests the safety of this approach for adolescents from a corneal biomechanics perspective.


Asunto(s)
Córnea , Tonometría Ocular , Adolescente , Niño , Humanos , Fenómenos Biomecánicos , Paquimetría Corneal , Topografía de la Córnea
18.
Ophthalmology ; 131(1): 107-121, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37855776

RESUMEN

PURPOSE: To review the published literature on the diagnostic capabilities of the newest generation of corneal imaging devices for the identification of keratoconus. METHODS: Corneal imaging devices studied included tomographic platforms (Scheimpflug photography, OCT) and functional biomechanical devices (imaging an air impulse on the cornea). A literature search in the PubMed database for English language studies was last conducted in February 2023. The search yielded 469 citations, which were reviewed in abstract form. Of these, 147 were relevant to the assessment objectives and underwent full-text review. Forty-five articles met the criteria for inclusion and were assigned a level of evidence rating by the panel methodologist. Twenty-six articles were rated level II, and 19 articles were rated level III. There were no level I evidence studies of corneal imaging for the diagnosis of keratoconus found in the literature. To provide a common cross-study outcome measure, diagnostic sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were extracted. (A perfect diagnostic test that identifies all cases properly has an AUC of 1.0.) RESULTS: For the detection of keratoconus, sensitivities for all devices and parameters (e.g., anterior or posterior corneal curvature, corneal thickness) ranged from 65% to 100%. The majority of studies and parameters had sensitivities greater than 90%. The AUCs ranged from 0.82 to 1.00, with the majority greater than 0.90. Combined indices that integrated multiple parameters had an AUC in the mid-0.90 range. Keratoconus suspect detection performance was lower with AUCs ranging from 0.66 to 0.99, but most devices and parameters had sensitivities less than 90%. CONCLUSIONS: Modern corneal imaging devices provide improved characterization of the cornea and are accurate in detecting keratoconus with high AUCs ranging from 0.82 to 1.00. The detection of keratoconus suspects is less accurate with AUCs ranging from 0.66 to 0.99. Parameters based on single anatomic locations had a wide range of AUCs. Studies with combined indices using more data and parameters consistently reported high AUCs. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Queratocono , Oftalmología , Humanos , Córnea/diagnóstico por imagen , Paquimetría Corneal/métodos , Topografía de la Córnea/métodos , Queratocono/diagnóstico por imagen , Curva ROC , Tomografía
19.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1022841

RESUMEN

Corneal refractive surgery is a safe and effective way to correct ametropia.Although the biomechanical stability of the cornea is reduced due to the change in corneal tissue integrity after surgery, the vast majority of postoperative corneal structures are safe.Patients with preoperative risk factors, such as high diopters, thin cornea, irregular corneal topography, high astigmatism, binocular asymmetry, allergic constitution, eye rubbing, etc., may experience postoperative refractive regression and corneal ectasia.Corneal collagen cross-linking can enhance the biomechanical properties of cornea and effectively prevent the occurrence and progression of corneal ectasia, keratoconus or other ectatic diseases.In recent years, many researchers at home and abroad have tried a new design of refractive surgery, that is, corneal refractive surgery with prophylactic corneal collagen cross-linking to improve the biomechanical stability of the cornea after refractive surgery, and then potentially prevent corneal ectasia and refractive regression.A number of studies have found that combined surgery has a good visual acuity and refractive prognosis, especially in patients at high risk for postoperative ectasia.This article reviews the efficacy, safety, predictability, stability, and complications of combined surgery.

20.
Artículo en Español | LILACS, CUMED | ID: biblio-1559884

RESUMEN

El queratocono es una afección inflamatoria, es una ectasia corneal que se caracteriza por un aumento de la curvatura corneal. Se describe como una enfermedad progresiva y asimétrica asociada con cambios estructurales en la organización del colágeno corneal. Existen diferentes opciones terapéuticas con el objetivo de estabilizar la superficie corneal, mejorar la visión y evitar su progresión. El sistema piggyback consiste en adaptar un lente rígido de gas permeable con alta permeabilidad al oxígeno sobre un lente de contacto hidrofílico, es ideal para pacientes que requieren la óptica de un lente de contacto rígido, pero tienen dificultades con su material. Se indica cuando existe una intolerancia a los lentes rígidos de gas permeable, en córneas irregulares y con curvaturas avanzadas. Se presenta una paciente de 24 años de edad con diagnóstico de queratocono desde los 10 años de edad que se corregía con lente rígido de gas permeable. Acudió a consulta del servicio de córnea del Instituto Cubano de Oftalmología Ramón Pando Ferrer, en el año 2010 porque comenzó a presentar intolerancia a los lentes. Debido a que la paciente no presentaba criterio quirúrgico y tenía una agudeza visual mejor corregida con lentes de 1,0 en ambos ojos, se decidió realizar el tratamiento con piggyback corneal. Pese al seguimiento, como parte de la progresión de la enfermedad, a los 10 años de mantenerse con el piggyback, presentó un hidrops corneal agudo, el cual fue tratado. En la actualidad la paciente mantiene seguimiento anual por consulta, sin progresión del queratocono y sin complicaciones con el tratamiento de piggyback corneal(AU)


Keratoconus is an inflammatory condition, a corneal ectasia characterized by increased corneal curvature. It is described as a progressive and asymmetric disease associated with structural changes in the organization of corneal collagen. There are different therapeutic options to stabilize the corneal surface, improve vision and prevent progression. The piggyback system consists of fitting a rigid gas permeable lens with high oxygen permeability over a hydrophilic contact lens, it is ideal for patients who require the optics of a rigid contact lens, but have difficulties with its material. It is indicated when there is intolerance to rigid gas permeable lenses, in irregular corneas and with advanced curvatures. We present a 24-year-old female patient with a diagnosis of keratoconus since she was 10 years old, which was corrected with a rigid gas permeable lens. She went to the cornea service of the Cuban Institute of Ophthalmology Ramón Pando Ferrer, in 2010 because she began to present intolerance to lenses. Since the patient did not present surgical criteria and had a visual acuity better corrected with 1.0 lenses in both eyes, it was decided to perform corneal piggyback treatment. Despite the follow-up, as part of the progression of the disease, after 10 years of piggyback, she presented an acute corneal hydrops, which was treated. At present, the patient maintains annual follow-up via consultation, without progression of keratoconus and without complications with the corneal piggyback treatment(AU)


Asunto(s)
Humanos , Masculino , Adulto Joven , Queratocono/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA