Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Trop Doct ; 54(2): 116-122, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38105600

RESUMEN

The quality of sterilisation and disinfection in a central sterile supply department is directly related to the quality of the hospital services and the patients' safety. Wet packs occasionally occur following the process of pressure steam sterilisation; reducing this occurrence is an important issue. Therefore, the causes of wet pack following sterilisation were analysed to identify the influencing factors and suggest improvements to prevent its occurrence. Understanding the sterilisation process and possible causes of exposure helps with risk assessment and identifying necessary corrective measures.


Asunto(s)
Vapor , Esterilización , Humanos , Vacio , Presión Sanguínea , Desinfección
2.
Chinese Journal of Nursing ; (12): 1361-1365, 2017.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-669023

RESUMEN

Objective To investigate the current situation of medical instrument cleaning in Central Sterile Supply Departments(CSSD),in order to identify problems and provide references for further improvements of equipment cleaning.Methods Questionnaire survey was adopted,data of 127 CSSDs in five coastal provinces or cities in China in 2017 were collected,and status of each link of medical instrument cleaning was analyzed.Results The allocation rate of ultrasonic cleaner and spray cleaner were 96.6% and 78.7%,respectively;62.2% of hospitals used tap water to pre-rinse,and 10.2% used normal saline or sterile water to pre-rinse,11.0% used tap water for finial rinsing;78.7% of hospitals did not perform continuous humidification in transit,and 18.1% of hospitals did not perform continuous humidification and their time of transit was more than 2 hours;66.9% of CSSDs only used multi-enzyme detergent.More than half of the hospitals did not record time for manual rinsing/manual final rinsing.Conclusion The configuration of medical instrument cleaning equipment of 127 CSSDs is good.However,it is necessary to pay more attention to cleaning details.Specifications for instrument cleaning water should be established;continuous humidification during transportation of medical instruments should be promoted;cleaning methods and cleaning detergents should be selected reasonably;standardized rinsing should be enhanced to ensure quality of medical instrument cleaning.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA