Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Europace ; 26(8)2024 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-39056247

RESUMEN

AIMS: Short-term ambulatory electrocardiogram (ECG) monitoring is often used to assess premature atrial complex (PAC) and premature ventricular complex (PVC) frequency, but the diagnostic reliability is unknown. The objective of this study was to study the day-to-day variability of PAC and PVC frequency. METHODS AND RESULTS: We used 14-day full-disclosure mobile cardiac telemetry recordings without atrial fibrillation in 8245 US patients aged 17-103 years to calculate the diagnostic reliability of shorter ambulatory ECG recordings compared with 14-day averages. Over 14 days, 1853 patients had ≥500 PACs/day, 410 patients had ≥5000 PACs/day, and 197 patients had ≥10 000 PACs/day; 1640 patients had ≥500 PVCs/day, 354 patients had ≥5000 PVCs/day, and 175 patients had ≥10 000 PVCs/day. After 3 days, the estimated daily PAC frequency differed by ≥50% from the 14-day mean in 25% of patients; for PVCs, the corresponding duration was 7 days. Ten days of monitoring were needed to estimate PAC and PVC frequency within ±20% of the overall 14-day frequency in 80% of patients. For daily PAC and PVC frequencies ≥10 000, single-day estimation had a specificity of 99.3% [95% confidence interval (CI) 99.1-99.5] at a sensitivity of 76.6 (95% CI 70.1-80.4%) for PACs and a 99.6% (95% CI 99.4-99.7%) specificity at 79.4 (95% CI 72.7-85.2) sensitivity for PVCs. After 7 days, the sensitivity increased to 88.8% (95% CI 83.6-92.9) for PACs and 86.9% (95% CI 80.9-91.5%) for PVCs. CONCLUSION: While there is substantial daily variability across most PAC and PVC levels, findings of ≥10 000 PACs or PVCs are highly specific and do not need to be confirmed with longer recordings.


Asunto(s)
Complejos Atriales Prematuros , Electrocardiografía Ambulatoria , Complejos Prematuros Ventriculares , Humanos , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/fisiopatología , Persona de Mediana Edad , Anciano , Reproducibilidad de los Resultados , Femenino , Complejos Atriales Prematuros/diagnóstico , Complejos Atriales Prematuros/fisiopatología , Electrocardiografía Ambulatoria/métodos , Adulto , Masculino , Adolescente , Anciano de 80 o más Años , Adulto Joven , Factores de Tiempo , Telemetría , Valor Predictivo de las Pruebas , Frecuencia Cardíaca
2.
Cardiovasc Revasc Med ; 64: 15-20, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38388248

RESUMEN

BACKGROUND: Conduction disturbances are a common complication of transcatheter aortic valve replacement (TAVR). Mobile Cardiac Telemetry (MCT) allows for continuous monitoring with near "real time" alerts and has allowed for timely detection of conduction abnormalities and pacemaker placement in small trials. A standardized, systematic approach utilizing MCT devices post TAVR has not been widely implemented, leading to variation in use across hospital systems. OBJECTIVES: Our aim was to evaluate the utility of a standardized, systematic approach utilizing routine MCT to facilitate safe and earlier discharge by identifying conduction disturbances requiring permanent pacemaker (PPM) placement. We also sought to assess the occurrence of actionable arrhythmias in post-TAVR patients. METHODS: Using guidance from the JACC Scientific Expert Panel, a protocol was implemented starting in December 2019 to guide PPM placement post-TAVR across our health system. All patients who underwent TAVR from December 2019 to June 2021 across four hospitals within Northwell Health, who did not receive or have a pre-existing PPM received an MCT device at discharge and were monitored for 30 days. Clinical and follow-up data were collected and compared to pre initiative patients. RESULTS: During the initiative 693 patients were monitored with MCT upon discharge, 21 of whom required PPM placement. Eight of these patients had no conduction abnormality on initial or discharge ECG. 59 (8.6 %) patients were found to have new atrial fibrillation or flutter via MCT monitoring. There were no adverse events in the initiative group. Prior to the initiative, 1281 patients underwent TAVR over a one-year period. The initiative group had significantly shorter length of stay than pre-initiative patients (2.5 ± 4.5 vs 3.0 ± 3.8 days, p < 0.001) and lower overall PPM placement rate within 30 days post-TAVR (16 % vs 20.5 %, P = 0.0125). CONCLUSIONS: In our study, implementation of a standardized, systematic approach utilizing MCT in post-TAVR patients was safe and allowed for timely detection of conduction abnormalities requiring pacemaker placement. This strategy also detected new atrial fibrillation and flutter. Reduction in post TAVR pacemaker rate and length of stay were also noted although this effect is multifactorial.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Arritmias Cardíacas , Estimulación Cardíaca Artificial , Marcapaso Artificial , Valor Predictivo de las Pruebas , Telemetría , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Masculino , Femenino , Anciano de 80 o más Años , Anciano , Factores de Tiempo , Resultado del Tratamiento , Telemetría/instrumentación , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Factores de Riesgo , Atención Ambulatoria , Frecuencia Cardíaca , Estudios Retrospectivos , Alta del Paciente , Potenciales de Acción
3.
Heart Rhythm O2 ; 4(8): 500-505, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37645265

RESUMEN

Background: Ventricular tachycardia (VT) occurs intermittently, unpredictably, and has potentially lethal consequences. Objective: Our aim was to derive a risk prediction model for VT episodes ≥10 beats detected on 30-day mobile cardiac telemetry based on the first 24 hours of the recording. Methods: We included patients who were monitored for 2 to 30 days in the United States using full-disclosure mobile cardiac telemetry, without any VT episode ≥10 beats on the first full recording day. An elastic net prediction model was derived for the outcome of VT ≥10 beats on monitoring days 2 to 30. Potential predictors included age, sex, and electrocardiographic data from the first 24 hours: heart rate; premature atrial and ventricular complexes occurring as singlets, couplets, triplets, and runs; and the fastest rate for each event. The population was randomly split into training (70%) and testing (30%) samples. Results: In a population of 19,781 patients (mean age 65.3 ± 17.1 years, 43.5% men), with a median recording time of 18.6 ± 9.6 days, 1510 patients had at least 1 VT ≥10 beats. The prediction model had good discrimination in the testing sample (area under the receiver-operating characteristic curve 0.7584, 95% confidence interval 0.7340-0.7829). A model excluding age and sex had an equally good discrimination (area under the receiver-operating characteristic curve 0.7579, 95% confidence interval 0.7332-0.7825). In the top quintile of the score, more than 1 in 5 patients had a VT ≥10 beats, while the bottom quintile had a 98.2% negative predictive value. Conclusion: Our model can predict risk of VT ≥10 beats in the near term using variables derived from 24-hour electrocardiography, and could be used to triage patients to extended monitoring.

4.
Cureus ; 15(2): e35465, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36999106

RESUMEN

Sick sinus syndrome (SSS) is a term used to describe dysfunction of the sinoatrial (SA) node that can lead to various cardiac arrhythmias that predominately manifest in the elderly. Commonly implicated arrhythmias vary from inappropriate bradycardia, tachycardia, sinus pauses, and rarely sinus arrest. Despite being a common reason for permanent pacemaker implantation, little is known regarding the incidence of SSS and there is even less reporting on SSS complicated by prolonged asystole. We present a case highlighting an infrequently observed manifestation of SSS with recurrent, prolonged ventricular asystolic episodes that were causing previously unexplained episodes of confusion and agonal breathing. Our patient was a 75-year-old male with a past medical history of hypertension, dyslipidemia, and prior transient ischemic attacks (TIAs) that presented after an acute mental status change. The initial leading differential diagnosis was believed to be a TIA and he was admitted to neurology service for further evaluation. The patient had recurring episodes of confusion associated with agonal breathing that upon closer review of the cardiac telemetry revealed sinus bradycardia to the 40s interrupted by several prolonged episodes of asystole, the longest lasting 20 seconds. Due to his symptoms and to avoid potential deterioration resulting in hemodynamic instability, the electrophysiology service urgently placed a temporary transvenous pacemaker and then later implanted a leadless pacemaker. On outpatient follow-up, he no longer had episodes of confusion, and no further asystolic episodes were noted on his device check.

5.
Front Cardiovasc Med ; 9: 912474, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36158797

RESUMEN

Background: The heart is commonly involved in COVID-19, and rhythm disorders have been largely reported. Objective: To evaluate the association of some non-cardiac and cardiac comorbidities and QT dispersion with arrhythmias and their impact on outcomes in hospitalized patients with COVID-19. Methods: Each patient underwent cardiac telemetry monitoring through the entire hospitalization period, laboratory analyses, 12-lead ECG, and lung imaging examination. Patients with arrhythmia were divided into three groups (bradyarrhythmias, tachyarrhythmias, and tachy- and bradyarrhythmias). Results: Two-hundred patients completed the study (males, 123; mean age, 70.1 years); of these, 80 patients (40%) exhibited rhythm disorders on telemetry. Patients with arrhythmia were older (p < 0.0001), had a greater number of comorbidities (p < 0.0001), higher values of creatinine (p = 0.007), B-type natriuretic peptide (p < 0.0001), troponin (p < 0.0001), C-reactive protein (p = 0.01), ferritin (p = 0.001), D-dimer (p < 0.0001), procalcitonin (p = 0.0008), QT interval (p = 0.002), QTc interval (p = 0.04), and QTc dispersion (p = 0.01), and lower values of sodium (p = 0.03), magnesium (p = 0.04), glomerular filtration rate (p < 0.0001), and hemoglobin (p = 0.008) as compared to patients without arrhythmia. By comparing the three subgroups of patients, no significant differences were found. At multivariate analysis, age [odds ratio (OR) = 1.14 (95% CI: 1.07-1.22); p = 0.0004], coronary artery disease [OR = 12.7 (95% CI: 2.38-68.01); p = 0.005], and circulating troponin [OR = 1.05 (95% CI: 1.003-1.10); p = 0.04] represented risk factors independently associated with arrhythmia. All-cause in-hospital mortality was ∼40-fold higher among patients with arrhythmia [OR = 39.66 (95% CI: 5.20-302.51); p = 0.0004]. Conclusion: Arrhythmias are associated with aging, coronary artery disease, subtle myocardial injury, hyperinflammatory status, coagulative unbalance, and prolonged QTc dispersion in patients with COVID-19, and confer a worse in-hospital prognosis. Given its usefulness, routinary use of cardiac telemetry should be encouraged in COVID wards.

6.
Kardiol Pol ; 80(1): 49-55, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34913475

RESUMEN

BACKGROUND: Despite the advancement of electrocardiogram (ECG) monitoring methods, the most important factor influencing diagnostic yield (DY) may still be monitoring duration. Ambulatory ECG monitoring, typically with 24-48 hours duration, is widely used but may result in underdiagnosis of rare arrhythmias. AIMS: This study aimed to examine the relationship between the DY and monitoring duration in a large patient cohort and investigate sex and age differences in the presentation of arrhythmias. METHODS: The study population consisted of 25 151 patients (57.8% women; median [interquartile range, IQR], 71 [64-78] years), who were examined with mobile cardiac telemetry during 2017 in the United States, using the PocketECGTM that continuously transmits a signal on a beat-to-beat basis. We investigated the occurrence of atrial fibrillation at a burden of both ≤1% (atrial fibrillation [AF], ≤1%) and ≤10% (AF ≤10%), premature ventricular contractions (PVC; >10 000 per 24 hours), non-sustained ventricular tachycardias (nsVT), sustained ventricular tachycardias (VT ≥30 seconds), atrioventricular blocks (AVB), pauses of >3 seconds duration, and bradycardia (heart rate <40 beats per minute for ≥60 seconds). RESULTS: The median (IQR) recording duration was 15.4, 8.2-28.2) days. The DY increased gradually with monitoring duration for all types of investigated arrhythmias. Compared to DY after up to 30 days of monitoring, a standard 24 hours monitoring resulted in DY for males/females of 20%/18% for AF ≤1%, 29%/28% for AF ≤10%, 45%/40% for PVCs, 17%/11% for nsVT, 17%/11% for VT ≥30 seconds, 49%/42 for AVB, 27%/20% for pauses, 36%/29% for bradycardia. CONCLUSION: A substantial number of patients suffering from arrhythmias may remain undiagnosed due to insufficient ECG monitoring time.


Asunto(s)
Fibrilación Atrial , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Revelación , Electrocardiografía Ambulatoria , Femenino , Humanos , Masculino , Taquicardia Ventricular/diagnóstico , Telemetría , Estados Unidos
7.
Am Heart J Plus ; 22: 100208, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38558904

RESUMEN

Background: Women are less likely to receive oral anticoagulation or ablation for treatment of atrial fibrillation (AF). Identification of sex differences in arrhythmia characteristics and symptoms may lead to a better understanding of potential reasons for these differences. Objectives: To determine sex differences in AF with respect to heart rate, duration, burden, and symptoms in patients undergoing mobile cardiac telemetry (MCT) monitoring. Methods: All patients who registered for ≤30-day MCT using PocketECG (MediLynx) in the USA in 2017 were included (n = 27,512, 58 % women). PocketECG records and transmits a three-lead ambulatory electrocardiogram (ECG) with real-time beat-to-beat analysis. Sex-related differences were analyzed with Chi2 and Spearmans rho. Results: Fewer women than men were diagnosed with AF lasting ≥30s (13.7 % versus [vs] 19.0 %, p < 0.001). AF burden was lower in women in all age groups <90 years (all p < 0.01). Women were older at the time of AF diagnosis (median 76 vs 73 years, p < 0.001), had faster heart rate during AF (mean: 104.7 ± 26.0 vs 96.7 ± 26.7 bpm, p < 0.001), and shorter AF duration (mean: 96.2 ± 176.0 vs 121.6 ± 189.9 min, p < 0.001). There was a non-significant trend toward more symptoms (such as dizziness, racing heart, fatigue, or palpitations) during AF in women compared to men (46.5 % vs 43.7 %, p = 0.062). Conclusions: AF was less prevalent and occurred at lower burdens in women than men in each age strata. Despite faster heart rates in AF in women, there were no significant sex differences in reported symptoms during AF. Sex differences in therapy cannot be explained by differences in symptoms or rates in AF. Condensed abstract: Real-world data on sex differences in AF using a 30-day MCT monitoring device remain scarce. We aim to determine the sex differences in AF with respect to prevalence, burden, heart rate, and symptom in patients undergoing ≤30-day MCT monitoring. Our data analysis suggests that fewer women than men had AF, women were older at diagnosis of AF, and women with AF had higher mean heart rate, shorter mean AF duration, and lower mean AF burden than men. Further studies are needed to examine reasons for sex differences, specifically in relation to AF therapy and its impact on clinical outcomes.

8.
Healthcare (Basel) ; 9(12)2021 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-34946336

RESUMEN

Due to the unprecedented COVID-19 pandemic, there may be overuse of telemetry monitoring compared to the pre-pandemic period. We compared the frequency of inappropriate telemetry use in the pre-COVID-19 period (1 November 2019 to 28 February 2020) versus the peri-COVID-19 period (1 March 2020 to 30 June 2020) at a major academic hospital in Honolulu, Hawaii, by a retrospective chart review to assess for the appropriateness of the telemetry orders during this period, based on the 2017 American College of Cardiology/American Heart Association guidelines. Compared to the pre-COVID-19 period, there was a significant increase in inappropriate telemetry use during the peri-COVID-19 period (X2 (1, N = 11,727) = 6.59, p = 0.0103). However, there was no increase in the proportions of respiratory failure (4.0%) or pneumonia (2.7%) during the peri-COVID-19 period. The increase in inappropriate telemetry use may be related to the uncertainty in clinical care and decision making amid the pandemic of the new virus. Appropriate utilization of telemetry monitoring is increasingly important during the pandemic due to the limited availability of resources. Further investigation is needed to clarify the relationship between the pandemic and trends in telemetry ordering.

9.
J Electrocardiol ; 67: 1-6, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33975077

RESUMEN

BACKGROUND: Minimizing direct patient contact among healthcare personnel is crucial for mitigating infectious risk during the coronavirus disease 2019 (COVID-19) pandemic. The use of remote cardiac telemetry as an alternative to 12­lead electrocardiography (ECG) for continuous QTc monitoring may facilitate this strategy, but its application has not yet been validated or implemented. METHODS: In the validation component of this two-part prospective cohort study, a total of 65 hospitalized patients with simultaneous ECG and telemetry were identified. QTc obtained via remote telemetry as measured by 3 independent, blinded operators were compared with ECG as assessed by 2 board-certified electrophysiologists as the gold-standard. Pearson correlation coefficients were calculated to measure the strength of linear correlation between the two methods. In a separate cohort comprised of 68 COVID-19 patients treated with combined hydroxychloroquine and azithromycin, telemetry-based QTc values were compared at serial time points after medication administration using Friedman rank-sum test of repeated measures. RESULTS: Telemetry-based QTc measurements highly correlated with QTc values derived from ECG, with correlation coefficients of 0.74, 0.79, 0.85 (individual operators), and 0.84 (mean of all operators). Among the COVID-19 cohort, treatment led to a median QTc increase of 15 milliseconds between baseline and following the 9th dose (p = 0.002), with 8 (12%) patients exhibiting an increase in QTc ≥ 60 milliseconds and 4 (6%) developing QTc ≥ 500 milliseconds. CONCLUSIONS: Cardiac telemetry is a validated clinical tool for QTc monitoring that may serve an expanding role during the COVID-19 pandemic strengthened by its remote and continuous monitoring capability and ubiquitous presence throughout hospitals.


Asunto(s)
COVID-19 , Síndrome de QT Prolongado , Atención a la Salud , Electrocardiografía , Humanos , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/epidemiología , Pandemias , Estudios Prospectivos , SARS-CoV-2 , Telemetría
10.
Cardiovasc Digit Health J ; 2(1): 4-54, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35265889

RESUMEN

This collaborative statement from the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia Pacific Heart Rhythm Society describes the current status of mobile health ("mHealth") technologies in arrhythmia management. The range of digital medical tools and heart rhythm disorders that they may be applied to and clinical decisions that may be enabled are discussed. The facilitation of comorbidity and lifestyle management (increasingly recognized to play a role in heart rhythm disorders) and patient self-management are novel aspects of mHealth. The promises of predictive analytics but also operational challenges in embedding mHealth into routine clinical care are explored.

11.
Heart Rhythm O2 ; 2(6Part A): 543-559, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34988499

RESUMEN

BACKGROUND: Clinicians rarely scrutinize the full disclosure of a myriad of FDA-approved long-term rhythm monitors, and they rely on manufacturers to detect and report relevant rhythm abnormalities. OBJECTIVE: The objective of this study is to compare the diagnostic accuracy between mobile cardiac telemetry (MCT), which uses an algorithm-based detection strategy, and continuous long-term electrocardiography (LT-ECG) monitoring, which uses a human-based detection strategy. METHODS: In an outpatient arrhythmia clinic, we enrolled 50 sequential patients ordered to wear a 30-day MCT, to simultaneously wear a continuous LT-ECG monitor. Periods of concomitant wear of both devices were examined using the associated report, which was over-read by 2 electrophysiologists. RESULTS: Forty-six of 50 patients wore both monitors simultaneously for an average of 10.3 ± 4.4 days (range: 1.2-14.8 days). During simultaneous recording, patients were more often diagnosed with arrhythmia by LT-ECG compared to MCT (23/46 vs 11/46), P = .018. Similarly, more arrhythmia episodes were detected during simultaneous recording with the LT-ECG compared to MCT (61 vs 19), P < .001. This trend remained consistent across arrhythmia subtypes, including ventricular tachycardia (13 patients by LT-ECG vs 7 by MCT), atrioventricular (AV) block (3 patients by LT-ECG vs 0 by MCT), and AV node reentrant tachycardia (2 patients by LT-ECG vs 0 by MCT). Atrial fibrillation (AF) was documented by both monitors in 2 patients; however, LT-ECG monitoring captured 4 additional AF episodes missed by MCT. CONCLUSION: In a time-controlled, paired analysis of 2 disparate rhythm monitors worn simultaneously, human-dependent LT-ECG arrhythmia detection significantly outperformed algorithm-based MCT arrhythmia detection.

12.
Clin Cardiol ; 42(10): 952-957, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31407351

RESUMEN

BACKGROUND: Cardiac telemetry monitoring is widely utilized for a variety of clinical indications, yet indication-specific event rates for monitored patients are seldomly reported. HYPOTHESIS: High-risk hospitalized patients for clinical deterioration can be identified using standardized telemetry monitoring indications. METHODS: Adjudicated data from events triggering emergency response team (ERT) activation were systematically characterized at the Cleveland Clinic from among standardized telemetry indications ordered over a 13-month period. RESULTS: Among 72 199 orders created for telemetry monitored patients, ERT activation occurred in 2677 patients (3.7%), of which 1326 (49.5%) were cardiac-related. Patients with deep venous thrombosis or pulmonary embolism (DVT/PE) demonstrated the highest overall event rate (ERT: n = 41 of 593 pts [6.9%]; 25/41 cardiac related [61%]). Cardiac-related events were proportionally highest among patients with coronary disease awaiting revascularization (ERT: n = 19 of 847 patients [2.2%]; 13/19 cardiac-related [68.4%]). Arrhythmia-specific events were highest among patients who underwent cardiac surgery (n = 78 of 193 cardiac-related ERT [40.4%]), and patients with known or suspected tachyarrhythmias (n = 318 of 788 cardiac-related ERT [40.4%]). Bubble plot analysis identified patients hospitalized with DVT/PE, drug or alcohol exposures, and acute coronary syndrome as among the highest overall and cardiac-related events while identifying patients with respiratory disorder monitoring indications as carrying the highest noncardiac event rate. CONCLUSION: High-risk hospitalized patients can be identified by telemetry indication and prioritized according to concerns for cardiac, arrhythmia-specific and noncardiac clinical deterioration. This is particularly useful when monitored bed resources are constrained.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Servicio de Urgencia en Hospital , Monitoreo Fisiológico/métodos , Telemetría/métodos , Enfermedades Cardiovasculares/epidemiología , Estudios de Seguimiento , Humanos , Incidencia , Ohio/epidemiología , Estudios Retrospectivos
14.
J Electrocardiol ; 54: 76-78, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30928821

RESUMEN

High grade atrioventricular (AV) block, defined as 2 or more non-conducted P waves, is a common indication for permanent pacemaker implantation and can be a cause of syncope or presyncope. A 61 year-old male presented to the emergency department with presyncopal symptoms and high grade AV block confirmed on electrocardiogram. Continuous cardiac telemetry monitoring did not trigger any alarm notification during episodes of AV block, due to T wave overcounting. The limitations of telemetry monitoring are rarely recognized and even more rarely reported in the literature.


Asunto(s)
Bloqueo Atrioventricular/diagnóstico , Telemetría , Bloqueo Atrioventricular/terapia , Bradicardia/diagnóstico , Bradicardia/terapia , Diagnóstico Diferencial , Electrocardiografía , Humanos , Masculino , Persona de Mediana Edad , Marcapaso Artificial
15.
J Innov Card Rhythm Manag ; 10(9): 3803-3808, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32477749

RESUMEN

Research on traditional cardiac telemetry demonstrates that excessive alarms are related to lead failures and noise-related interruptions. Patch-based continuous cardiac rhythm monitoring (CCRM) has emerged in outpatient ambulatory monitoring situations as a means to improve recording fidelity. In this study, patients hospitalized but not in the intensive care unit were simultaneously monitored via telemetry in parallel with the use of the Vital Signs Patch™ (VSP) CCRM system (LifeWatch Services, Rosemont, IL, USA), applying standardized monitoring and notifications provided by an off-site central monitoring unit (CMU). Among 11 patients (55% male; age: 66.8 ± 12.5 years), there were 42 CMU detections and 98 VSP detections. The VSP device was successfully applied by nursing with connectivity established in all 11 patients (100%). There were no VSP device-related adverse events or skin eruptions during the study. The CMU agreed with 59 (60%) of 98 VSP detections. Among those detections marked by disagreement 30 (77%) of 39 VSP detections were related to clinically meaningful arrhythmias (atrial: n = 9; ventricular: n = 7; brady-: n = 14) undetected by VSP due to noise. In two patients (18%), there were four clinically meaningful atrial fibrillation detections not recorded by the CMU. In conclusion, patch-based CCRM requires further development and review to replace traditional cardiac telemetry monitoring but could evolve into an appropriate method to detect clinically meaningful events missed by traditional methods if noise issues can be mitigated.

16.
J Electrocardiol ; 50(6): 833-840, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28985886

RESUMEN

Although automated ECG analysis has been available for many years, there are some aspects which require to be re-assessed with respect to their value while newer techniques which are worthy of review are beginning to find their way into routine use. At the annual International Society of Computerized Electrocardiology conference held in April 2017, four areas in particular were debated. These were a) automated 12 lead resting ECG analysis; b) real time out of hospital ECG monitoring; c) ECG imaging; and d) single channel ECG rhythm interpretation. One speaker presented the positive aspects of each technique and another outlined the more negative aspects. Debate ensued. There were many positives set out for each technique but equally, more negative features were not in short supply, particularly for out of hospital ECG monitoring.


Asunto(s)
Automatización , Diagnóstico por Computador , Electrocardiografía , Procesamiento de Señales Asistido por Computador , Humanos , Sociedades Médicas
17.
Cureus ; 9(5): e1282, 2017 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-28680770

RESUMEN

Non-invasive cardiac monitoring has well-established indications and protocols. Telemetry is often overused leading to a shortage of tele-beds and an increment of hospital expenses. In some cases, patients are kept on telemetry longer than the indicated length because providers are unaware of its ongoing use. We investigated the effect of reminder pop-ups, incorporated into an electronic medical record (EMR), on minimizing the use of telemetry. Three regional hospitals implemented an electronic pop-up reminder for discontinuing the use of telemetry when no longer indicated. A retrospective analysis of data for patients on telemetry, outside of the intensive care unit (ICU), was conducted and comparisons were drawn from pre- and post-implementation periods. A composite analysis of the number of days on telemetry was calculated using the Kruskal-Wallis test. With the implementation of the pop-up reminder, the median number of days on telemetry was significantly lower in 2016 than in 2015 (2.25 vs 3.61 days, p < 0.0001). Overutilization of telemetry is widely recognized, despite not being warranted in non-ICU hospitalizations. The implementation of a pop-up reminder built into the electronic medical record system reduced the overuse of telemetry by 37% between the two time periods studied.

18.
Worldviews Evid Based Nurs ; 14(4): 265-273, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28432853

RESUMEN

BACKGROUND: It is estimated that between 80% and 99% of alarms in the clinical areas are in actionable alarms (Gross, Dahl, & Nielson). Alarm management is one of the Joint Commission's National Patient Safety Goals (2014) because sentinel events have directly been linked to the devices generating these alarms. PURPOSE: At an acute care facility in Boston, a multidisciplinary team consisting of Nursing, Biomedical Engineers, Patient Safety and Providers was formed to conduct a pilot study on the state of telemetry alarms on a surgical floor. METHODS: An evidence-based approach was taken utilizing Philips Real-time data exporter alarms tracking software to capture all telemetry alarms during a 43-day time span. Likewise, noise meters were placed near telemetry alarm speakers to track decibel levels within the aforementioned timeframe for 21 days. Analysis of the data showed that clinically insignificant Premature Ventricular Contractions (PVC) alarms accounted for more than 40% of all alarms in the unit within the time span, while also contributing to an average noise level of 58.49 dB. In response to the data, the interdisciplinary team approved to permanently default the settings for PAIR PVC, MULTIFORM PVC, and RUN PVC alarms to off. RESULTS: The results showed a 54% decrease in the rate of alarms per bed per day, and an average noise reduction of 2.3 dB between the two selected noise measurement areas. LINKING EVIDENCE TO ACTION: Organizing a multidisciplinary team provides an effective framework toward analyzing and addressing cardiac telemetry alarm fatigue. Looking at quantitative datasets for clinical care areas through various lenses helps identify opportunities for improvement in regards to highlighting alarms that are not actionable. Pilot changes to alarm parameters can be tested for their environmental impact in the care area.


Asunto(s)
Alarmas Clínicas/efectos adversos , Práctica Clínica Basada en la Evidencia/métodos , Fatiga/etiología , Monitoreo Fisiológico/psicología , Ruido/efectos adversos , Boston , Agotamiento Profesional/prevención & control , Agotamiento Profesional/psicología , Alarmas Clínicas/normas , Enfermería de Cuidados Críticos , Fatiga/complicaciones , Humanos , Monitoreo Fisiológico/efectos adversos , Monitoreo Fisiológico/métodos , Enfermeras y Enfermeros/psicología , Proyectos Piloto , Mejoramiento de la Calidad , Telemetría/efectos adversos , Telemetría/instrumentación , Telemetría/métodos , Complejos Prematuros Ventriculares/complicaciones , Complejos Prematuros Ventriculares/psicología , Recursos Humanos
19.
Postgrad Med J ; 93(1101): 430-435, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28455284

RESUMEN

BACKGROUND: Alarm fatigue (AF) is a distressing factor for staff and patients in the hospital. Using cardiac telemetry (CT) without clinical indications can create unnecessary alarms, and increase AF and cost of healthcare. We sought to reduce AF and cost associated with CT monitoring. METHODS: After implementing a new protocol for CT placement, data were collected on telemetry orders, alarms and bed cost for 13 weeks from 1 January 2015 through 31 March 2015. We also retrospectively collected data on the same variables for the 13 weeks prior to the intervention. A survey was administered to nurses to assess past and present perceptions of AF. Interventions included protocol creation and education for participants. RESULTS: At baseline, 77% of patients were monitored with CT. A total of 145 (31%) order discrepancies were discovered during data collection, of which 72% had no indication for CT, so CT was discontinued. The other 28% had indications, so orders were placed. A total of 8336 alarms were recorded during 4 weeks of data collection, of which 333 (4%) were classified as true actionable alarms. Postintervention data showed 67% CT assignment with 10% reduction in CT usage, with no increase in mortality (p<0.001 and >0.05, respectively). A 42% cost reduction was achieved after adjusting the patient status. Nurses reported 27% perceived reduction in AF. One-year follow-up revealed that 69% of patients were being monitored by CT, and the rate of order discrepancies due to lack of indication was 9%. CONCLUSION: All hospital units may benefit from the protocols created during this study. If applied appropriately, these protocols can lead to reduced AF and cost per episode of care.


Asunto(s)
Agotamiento Profesional/prevención & control , Cardiología/instrumentación , Alarmas Clínicas , Fatiga/prevención & control , Mejoramiento de la Calidad , Telemetría , Humanos , Estudios Retrospectivos
20.
Med Devices (Auckl) ; 7: 1-5, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24353449

RESUMEN

INTRODUCTION: This research is meant to establish if a patient monitored with mobile cardiac telemetry (MCT) sees different outcomes regarding diagnostic yield of arrhythmia, therapeutic management through the use of antiarrhythmic drugs, and cardiovascular costs incurred in the hospital setting when compared with more traditional monitoring devices, such as the Holter or the Event monitor. MATERIALS AND METHODS: We conducted a retrospective analysis spanning 57 months of claims data from January 2007 to September 2011 pertaining to 200,000+ patients, of whom 14,000 used MCT only, 54,000 an Event monitor only, and 163,000 a Holter monitor only. Those claims came from the Truven database, an employer database that counts 2.8 million cardiovascular patients from an insured population of about 10 million members. We employed a pair-wise pre/post test-control methodology, and ensured that control patients were similar to test patients along the following dimensions: age, geographic location, type of cardiovascular diagnosis both in the inpatient and outpatient settings, and the cardiovascular drug class the patient uses. RESULTS: First, the diagnostic yield of patients monitored with MCT is 61%, that is significantly higher than that of patients that use the Event monitor (23%) or the Holter monitor (24%). Second, patients naive to antiarrhythmic drugs initiate drug therapy after monitoring at the following rates: 61% for patients that use MCT compared with 39% for patients that use the Event and 43% for patients that use the Holter. Third, there are very significant inpatient cardiovascular savings (in the tens of thousands of dollars) for patients that undergo ablation, coronary artery bypass graft (CABG) and valve septa. Savings are more modest but nonetheless significant when it comes to the heart/pericardium procedure. CONCLUSION: Given the superior outcome of MCT regarding both patient care and hospital savings, hospitals only stand to gain by enforcing protocols that favor the MCT system over the Event or the Holter monitor.

SELECCIÓN DE REFERENCIAS