Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
1.
EJNMMI Res ; 14(1): 85, 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39294533

RESUMEN

BACKGROUND: Cardiac positron emission tomography (PET) offers non-invasive assessment of perfusion and left ventricular (LV) function from a single dynamic scan. However, no prior assessment of mitral regurgitation severity by PET has been presented. Application of indicator dilution techniques and gated image analyses to PET data enables calculation of forward stroke volume and total LV stroke volume. We aimed to evaluate a combination of these methods for measurement of regurgitant volume (RegVol) and fraction (RegF) using dynamic 15O-water and 11C-acetate PET in comparison to cardiovascular magnetic resonance (CMR). RESULTS: Twenty-one patients with severe primary mitral valve regurgitation underwent same-day dynamic PET examinations (15O-water and 11C-acetate) and CMR. PET data were reconstructed into dynamic series with short time frames during the first pass, gated 15O-water blood pool images, and gated 11C-acetate myocardial uptake images. PET-based RegVol and RegF correlated strongly with CMR (RegVol: 15O-water r = 0.94, 11C-acetate r = 0.91 and RegF: 15O-water r = 0.88, 11C-acetate r = 0.84, p < 0.001). A systematic underestimation (bias) was found for PET (RegVol: 15O-water - 11 ± 13 mL, p = 0.002, 11C-acetate - 28 ± 16 mL, p < 0.001 and RegF: 15O-water - 4 ± 6%, p = 0.01, 11C-acetate - 10 ± 7%, p < 0.001). PET measurements in patients were compared to healthy volunteers (n = 18). Mean RegVol and RegF was significantly lower in healthy volunteers compared to patients for both tracers. The accuracy of diagnosing moderately elevated regurgitant volume (> 30mL) was 95% for 15O-water and 92% for 11C-acetate. CONCLUSIONS: LV regurgitation severity quantified using cardiac PET correlated with CMR and showed high accuracy for discriminating patients from healthy volunteers.

3.
Front Physiol ; 15: 1296537, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39135706

RESUMEN

Introduction: Elite breath-hold divers (BHD) possess several oxygen conserving adaptations to endure long dives similar to diving mammals. During dives, Bottlenose Dolphins may increase the alveolar ventilation (VA) to perfusion (Q) ratio to increase alveolar oxygen delivery. We hypothesized that BHD possess similar adaptive mechanisms during apnea. Methods and results: Pulmonary blood volume (PBV) was determined by echocardiography, 15O-H2O PET/CT, and cardiac MRi, (n = 6) during and after maximum apneas. Pulmonary function was determined by body box spirometry and compared to matched controls. After 2 min of apnea, the PBV determined by echocardiography and 15O-H2O-PET/CT decreased by 26% and 41%, respectively. After 4 min of apnea, the PBV assessed by echocardiography and cardiac MRi decreased by 48% and 67%, respectively (n = 6). Fractional saturation (F)O2Hb determined by arterial blood-gas-analyses collected after warm-up and a 5-minute pool-apnea (n = 9) decreased by 43%. Compared to matched controls (n = 8), spirometry revealed a higher total and alveolar-lung-capacity in BHD (n = 9), but a lower diffusion-constant. Conclusion: Our results contrast with previous studies, that demonstrated similar lung gas transfer in BHD and matched controls. We conclude that elite BHD 1) have a lower diffusion constant than matched controls, and 2) gradually decrease PBV during apnea and in turn increase VA/Q to increase alveolar oxygen delivery during maximum apnea. We suggest that BHD possess pulmonary adaptations similar to diving mammals to tolerate decreasing tissue oxygenation. New and noteworthy: This manuscript addresses novel knowledge on tolerance to hypoxia during diving, which is shared by elite breath-hold divers and adult diving mammals: Our study indicates that elite breath-hold divers gradually decrease pulmonary blood volume and in turn increase VA/Q, to increase alveolar oxygen delivery during maximum apnea to tolerate decreasing oxygen levels similar to the Bottlenose Dolphin.

4.
Diagnostics (Basel) ; 14(16)2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39202193

RESUMEN

PURPOSE: Cardiac 2-deoxy-2-[F-18]fluoro-D-glucose positron emission tomography (FDG PET) is widely used to assess myocardial viability in patients with ischemic heart disease. While sufficient glucose uptake is a prerequisite for accurate interpretation of cardiac viability, there are a lack of data on which clinical variables have the most significant impact on myocardial glucose metabolism. Therefore, this study was designed to evaluate several clinical variables that could affect myocardial glucose metabolism. METHODS: A total of 214 consecutive cases were retrospectively enrolled in this study. All subjects received 250 mg of acipimox and underwent glucose loading as preparation for cardiac FDG PET/CT. Three-dimensional regions of interest (ROIs) were drawn on PET/CT fusion images. Myocardial glucose uptake ratio (MGUR = SUVmax of LV myocardium/SUVmean of liver) was then calculated. Multiple clinical variables including body mass index (BMI), blood glucose levels at different times, administered insulin dosage, lipid profiles, and ejection fraction were measured and analyzed for correlation with myocardial glucose uptake. After dichotomizing the subjects based on a BMI of 25, each group's MGUR was compared. RESULTS: Myocardial uptake showed significant correlations with BMI (r = -0.162, p = 0.018), HbA1c (r = -0.150, p = 0.030), and triglyceride levels (r = -0.137, p = 0.046). No other clinical variables showed a significant correlation with myocardial glucose uptake. After multiple linear regression analysis, BMI (p = 0.032) and HbA1c (p = 0.050) showed a correlation with MGUR. In group analysis, after dividing patients based on BMI, the obese group showed significantly lower myocardial uptake than the non-obese group (3.8 ± 1.9 vs. 4.4 ± 2.1, p = 0.031). CONCLUSIONS: Among several clinical variables, BMI and HbA1c levels were related to myocardial glucose uptake. A prospective study would be needed to examine whether a protocol that additionally considers BMI and HbA1c levels is necessary for the current cardiac FDG PET protocol.

5.
JACC Adv ; 3(5): 100933, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38939635
6.
Ann Nucl Med ; 38(10): 775-788, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38842629

RESUMEN

BACKGROUND: Cardiac positron emission tomography (PET) can visualize and quantify the molecular and physiological pathways of cardiac function. However, cardiac and respiratory motion can introduce blurring that reduces PET image quality and quantitative accuracy. Dual cardiac- and respiratory-gated PET reconstruction can mitigate motion artifacts but increases noise as only a subset of data are used for each time frame of the cardiac cycle. AIM: The objective of this study is to create a zero-shot image denoising framework using a conditional generative adversarial networks (cGANs) for improving image quality and quantitative accuracy in non-gated and dual-gated cardiac PET images. METHODS: Our study included retrospective list-mode data from 40 patients who underwent an 18F-fluorodeoxyglucose (18F-FDG) cardiac PET study. We initially trained and evaluated a 3D cGAN-known as Pix2Pix-on simulated non-gated low-count PET data paired with corresponding full-count target data, and then deployed the model on an unseen test set acquired on the same PET/CT system including both non-gated and dual-gated PET data. RESULTS: Quantitative analysis demonstrated that the 3D Pix2Pix network architecture achieved significantly (p value<0.05) enhanced image quality and accuracy in both non-gated and gated cardiac PET images. At 5%, 10%, and 15% preserved count statistics, the model increased peak signal-to-noise ratio (PSNR) by 33.7%, 21.2%, and 15.5%, structural similarity index (SSIM) by 7.1%, 3.3%, and 2.2%, and reduced mean absolute error (MAE) by 61.4%, 54.3%, and 49.7%, respectively. When tested on dual-gated PET data, the model consistently reduced noise, irrespective of cardiac/respiratory motion phases, while maintaining image resolution and accuracy. Significant improvements were observed across all gates, including a 34.7% increase in PSNR, a 7.8% improvement in SSIM, and a 60.3% reduction in MAE. CONCLUSION: The findings of this study indicate that dual-gated cardiac PET images, which often have post-reconstruction artifacts potentially affecting diagnostic performance, can be effectively improved using a generative pre-trained denoising network.


Asunto(s)
Corazón , Procesamiento de Imagen Asistido por Computador , Tomografía de Emisión de Positrones , Relación Señal-Ruido , Humanos , Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía de Emisión de Positrones/métodos , Estudios Retrospectivos , Fluorodesoxiglucosa F18 , Masculino , Femenino , Técnicas de Imagen Sincronizada Cardíacas/métodos , Artefactos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Persona de Mediana Edad
7.
Basic Res Cardiol ; 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38922408

RESUMEN

Combined [18F]FDG PET-cardiac MRI imaging (PET/CMR) is a useful tool to assess myocardial viability and cardiac function in patients with acute myocardial infarction (AMI). Here, we evaluated the prognostic value of PET/CMR in a porcine closed-chest reperfused AMI (rAMI) model. Late gadolinium enhancement by PET/CMR imaging displayed tracer uptake defect at the infarction site by 3 days after the rAMI in the majority of the animals (group Match, n = 28). Increased [18F]FDG uptake at the infarcted area (metabolism/contractility mismatch) with reduced tracer uptake in the remote viable myocardium (group Mismatch, n = 12) 3 days after rAMI was observed in the animals with larger infarct size and worse left ventricular ejection fraction (LVEF) (34 ± 8.7 vs 42.0 ± 5.2%), with lower LVEF also at the 1-month follow-up (35.8 ± 9.5 vs 43.0 ± 6.3%). Transcriptome analyses by bulk and single-nuclei RNA sequencing of the infarcted myocardium and border zones (n = 3 of each group, and 3 sham-operated controls) revealed a strong inflammatory response with infiltration of monocytes and macrophages in the infarcted and border areas in Mismatch animals. Our data indicate a high prognostic relevance of combined PET/MRI in the subacute phase of rAMI for subsequent impairment of heart function and underline the adverse effects of an excessive activation of the innate immune system in the initial phase after rAMI.

8.
Am Heart J Plus ; 43: 100399, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38828445

RESUMEN

Chest pain, a common symptom in cardiovascular care, often leads to the investigation of obstructive coronary artery disease (CAD). However, many patients experience chest pain without obstructive CAD, termed INOCA (Ischemia with Non-Obstructive Coronary Arteries) or CMD (Coronary Microvascular Dysfunction). INOCA can be attributed to endothelial dysfunction, vascular smooth muscle dysfunction, or both, affecting about 20-30 % of patients with nonobstructive CAD. The diagnostic approach for INOCA includes both invasive and non-invasive methods, with cardiac PET (Positron Emission Tomography) playing a significant role in risk stratification and management. PET evaluates various parameters like myocardial blood flow under stress and rest, myocardial flow reserve, and myocardial ischemia. Such comprehensive assessment is essential in accurately diagnosing and managing INOCA, considering the complexity of this condition.

9.
Front Physiol ; 15: 1305171, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38745836

RESUMEN

Introduction: Elite breath-hold divers (BHD) enduring apneas of more than 5 min are characterized by tolerance to arterial blood oxygen levels of 4.3 kPa and low oxygen-consumption in their hearts and skeletal muscles, similar to adult seals. Adult seals possess an adaptive higher hemoglobin-concentration and Bohr effect than pups, and when sedated, adult seals demonstrate a blood shift from the spleen towards the brain, lungs, and heart during apnea. We hypothesized these observations to be similar in human BHD. Therefore, we measured hemoglobin- and 2,3-biphosphoglycerate-concentrations in BHD (n = 11) and matched controls (n = 11) at rest, while myocardial mass, spleen and lower extremity volumes were assessed at rest and during apnea in BHD. Methods and results: After 4 min of apnea, left ventricular myocardial mass (LVMM) determined by 15O-H2O-PET/CT (n = 6) and cardiac MRI (n = 6), was unaltered compared to rest. During maximum apnea (∼6 min), lower extremity volume assessed by DXA-scan revealed a ∼268 mL decrease, and spleen volume, assessed by ultrasonography, decreased ∼102 mL. Compared to age, BMI and VO2max matched controls (n = 11), BHD had similar spleen sizes and 2,3- biphosphoglycerate-concentrations, but higher total hemoglobin-concentrations. Conclusion: Our results indicate: 1) Apnea training in BHD may increase hemoglobin concentration as an oxygen conserving adaptation similar to adult diving mammals. 2) The blood shift during dry apnea in BHD is 162% more from the lower extremities than from the spleen. 3) In contrast to the previous theory of the blood shift demonstrated in sedated adult seals, blood shift is not towards the heart during dry apnea in humans.

10.
Curr Cardiol Rep ; 26(7): 723-734, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38806976

RESUMEN

PURPOSE OF REVIEW: Recent studies have demonstrated an association between obstructive sleep apnea (OSA) and abnormal myocardial blood flow (MBF), myocardial flow reserve (MFR), and coronary microvascular dysfunction (CMD). Here, we review the evidence and describe the potential underlying mechanisms linking OSA to abnormal MBF. Examining relevant studies, we assess the impact of OSA-specific therapy, such as continuous positive airway pressure (CPAP), on MBF. RECENT FINDINGS: Recent studies suggest an association between moderate to severe OSA and abnormal MBF/MFR. OSA promotes functional and structural abnormalities of the coronary microcirculation. OSA also promotes the uncoupling of MBF to cardiac work. In a handful of studies with small sample sizes, CPAP therapy improved MBF/MFR. Moderate to severe OSA is associated with abnormal MFR, suggesting an association with CMD. Evidence suggests that CPAP therapy improves MBF. Future studies must determine the clinical impact of improved MBF with CPAP.


Asunto(s)
Enfermedades Cardiovasculares , Presión de las Vías Aéreas Positiva Contínua , Circulación Coronaria , Microcirculación , Apnea Obstructiva del Sueño , Humanos , Apnea Obstructiva del Sueño/terapia , Apnea Obstructiva del Sueño/fisiopatología , Apnea Obstructiva del Sueño/complicaciones , Circulación Coronaria/fisiología , Microcirculación/fisiología , Enfermedades Cardiovasculares/fisiopatología , Enfermedades Cardiovasculares/etiología , Reserva del Flujo Fraccional Miocárdico/fisiología
11.
J Nucl Cardiol ; 38: 101884, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38761831

RESUMEN

BACKGROUND: Data on cardiac positron emission tomography (PET) in liver transplantation (LT) candidates are limited with no prior study accounting for poorly metabolized caffeine reducing stress perfusion. METHOD: Consecutive LT candidates (n = 114) undergoing cardiac rest/stress PET were instructed to abstain from caffeine for 2 days extended to 5 and 7 days. Due to persistently high prevalence of measurable blood caffeine after 5-day caffeine abstinence, dipyridamole (n = 41) initially used was changed to dobutamine (n = 73). Associations of absolute flow, coronary flow reserve (CFR), detectable blood caffeine, and Modified End-Stage Liver Disease (MELD) score for liver failure severity were evaluated. Coronary flow data of LT candidates were compared to non-LT control group (n = 102 for dipyridamole, n = 29 for dobutamine). RESULTS: Prevalence of patients with detectable blood caffeine was 63.3%, 36.7% and 33.3% after 2-, 5- and 7-day of caffeine abstinence, respectively. MELD score was associated with detectable caffeine (odd ratio 1.18,P < 0.001). CFR was higher during dipyridamole stress without-caffeine versus with-caffeine (2.22 ± 0.80 vs 1.55 ± 0.37,P = 0.048) but lower than dobutamine stress (2.22 ± 0.80 vs 2.82 ± 1.02,P = 0.026). Mediation analysis suggested that the dominant association between CFR and MELD score in dipyridamole group derived from caffeine-impaired CFR and liver failure/caffeine interaction. CFR in LT candidates was lower than non-LT control population in both dipyridamole and dobutamine group. CONCLUSION: We demonstrate exceptionally high prevalence of detectable blood caffeine in LT candidates undergoing stress PET myocardial perfusion imaging resulting in reduced CFR with dipyridamole compared to dobutamine. The delayed caffeine clearance in LT candidates makes dobutamine a preferred stress agent in this population.


Asunto(s)
Cafeína , Dipiridamol , Dobutamina , Trasplante de Hígado , Imagen de Perfusión Miocárdica , Vasodilatadores , Humanos , Masculino , Femenino , Persona de Mediana Edad , Cafeína/sangre , Imagen de Perfusión Miocárdica/métodos , Circulación Coronaria/efectos de los fármacos , Tomografía de Emisión de Positrones , Anciano , Adulto , Vasodilatación/efectos de los fármacos
12.
Med Image Anal ; 96: 103190, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38820677

RESUMEN

Inter-frame motion in dynamic cardiac positron emission tomography (PET) using rubidium-82 (82Rb) myocardial perfusion imaging impacts myocardial blood flow (MBF) quantification and the diagnosis accuracy of coronary artery diseases. However, the high cross-frame distribution variation due to rapid tracer kinetics poses a considerable challenge for inter-frame motion correction, especially for early frames where intensity-based image registration techniques often fail. To address this issue, we propose a novel method called Temporally and Anatomically Informed Generative Adversarial Network (TAI-GAN) that utilizes an all-to-one mapping to convert early frames into those with tracer distribution similar to the last reference frame. The TAI-GAN consists of a feature-wise linear modulation layer that encodes channel-wise parameters generated from temporal information and rough cardiac segmentation masks with local shifts that serve as anatomical information. Our proposed method was evaluated on a clinical 82Rb PET dataset, and the results show that our TAI-GAN can produce converted early frames with high image quality, comparable to the real reference frames. After TAI-GAN conversion, the motion estimation accuracy and subsequent myocardial blood flow (MBF) quantification with both conventional and deep learning-based motion correction methods were improved compared to using the original frames. The code is available at https://github.com/gxq1998/TAI-GAN.


Asunto(s)
Imagen de Perfusión Miocárdica , Tomografía de Emisión de Positrones , Radioisótopos de Rubidio , Humanos , Tomografía de Emisión de Positrones/métodos , Imagen de Perfusión Miocárdica/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos
14.
Ann Nucl Med ; 38(1): 31-70, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37952197

RESUMEN

We focus on reviewing state-of-the-art developments of dedicated PET scanners with irregular geometries and the potential of different aspects of multifunctional PET imaging. First, we discuss advances in non-conventional PET detector geometries. Then, we present innovative designs of organ-specific dedicated PET scanners for breast, brain, prostate, and cardiac imaging. We will also review challenges and possible artifacts by image reconstruction algorithms for PET scanners with irregular geometries, such as non-cylindrical and partial angular coverage geometries and how they can be addressed. Then, we attempt to address some open issues about cost/benefits analysis of dedicated PET scanners, how far are the theoretical conceptual designs from the market/clinic, and strategies to reduce fabrication cost without compromising performance.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía de Emisión de Positrones , Humanos , Fantasmas de Imagen , Tomografía de Emisión de Positrones/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Encéfalo , Algoritmos
15.
Ann Nucl Cardiol ; 9(1): 33-39, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38058574

RESUMEN

Background: Myocardial blood flow quantification (MBF) is one of the distinctive features for cardiac positron emission tomography. The MBF calculation is mostly obtained by estimating the input function from the time activity curve in dynamic scan. However, there is a substantial risk of count-loss because the high radioactivity pass through the left ventricular (LV) cavity within a short period. We aimed to determine the optimal intraventricular activity using the noise equivalent count rate (NECR) analysis with simplified phantom model. Methods: Positron emission tomography computed tomography scanner with LYSO crystal and time of flight was used for phantom study. 150 MBq/mL of 13N was filled in 10 mL of syringe, placed in neck phantom to imitate end-systolic small LV. 3D list-mode acquisition was repeatedly performed along radioactive decay. Net true and random count rate were calculated and compared to the theoretical activity in the syringe. NECR curve analysis was used to determine the optimal radioactive concentration. Result: The attenuation curves showed good correlation to the theoretical activity between 20 to 370, and 370 to 740 MBq (r2=1.0 ± 0.0001, p<0.0001; r2=0.99 ± 0.0001, p<0.0001 for 20 to 370, and 370 to 740, respectively), while did not over 740 MBq (p=0.62). NECR analysis revealed that the peak rate was at 2.9 Mcps, there at the true counts were significantly suppressed. The optimal radioactive concentration was determined as 36 MBq/mL. Conclusion: Simulative analysis for high-dose of 13N using the phantom imitating small LV confirmed that the risk of count-loss was increased. The result can be useful information in assessing the feasibility of MBF quantification in clinical routine.

16.
Eur J Nucl Med Mol Imaging ; 51(1): 123-135, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37787848

RESUMEN

BACKGROUND AND AIMS: Although treatment of ischemia-causing epicardial stenoses may improve symptoms of ischemia, current evidence does not suggest that revascularization improves survival. Conventional myocardial ischemia imaging does not uniquely identify diffuse atherosclerosis, microvascular dysfunction, or nonobstructive epicardial stenoses. We sought to evaluate the prognostic value of integrated myocardial flow reserve (iMFR), a novel noninvasive approach to distinguish the perfusion impact of focal atherosclerosis from diffuse coronary disease. METHODS: This study analyzed a large single-center registry of consecutive patients clinically referred for rest-stress myocardial perfusion positron emission tomography. Cox proportional hazards modeling was used to assess the association of two previously reported and two novel perfusion measures with mortality risk: global stress myocardial blood flow (MBF); global myocardial flow reserve (MFR); and two metrics derived from iMFR analysis: the extents of focal and diffusely impaired perfusion. RESULTS: In total, 6867 patients were included with a median follow-up of 3.4 years [1st-3rd quartiles, 1.9-5.0] and 1444 deaths (21%). Although all evaluated perfusion measures were independently associated with death, diffusely impaired perfusion extent (hazard ratio 2.65, 95%C.I. [2.37-2.97]) and global MFR (HR 2.29, 95%C.I. [2.08-2.52]) were consistently stronger predictors than stress MBF (HR 1.62, 95%C.I. [1.46-1.79]). Focally impaired perfusion extent (HR 1.09, 95%C.I. [1.03-1.16]) was only moderately related to mortality. Diffusely impaired perfusion extent remained a significant independent predictor of death when combined with global MFR (p < 0.0001), providing improved risk stratification (overall net reclassification improvement 0.246, 95%C.I. [0.183-0.310]). CONCLUSIONS: The extent of diffusely impaired perfusion is a strong independent and additive marker of mortality risk beyond traditional risk factors, standard perfusion imaging, and global MFR, while focally impaired perfusion is only moderately related to mortality.


Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Humanos , Constricción Patológica , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía de Emisión de Positrones , Perfusión , Isquemia , Imagen de Perfusión Miocárdica/métodos , Circulación Coronaria
17.
Magn Reson Imaging Clin N Am ; 31(4): 613-624, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37741645

RESUMEN

In the last few years, technological advances in MR imaging, PET detectors, and attenuation correction algorithms have allowed the creation of truly integrated PET/MR imaging systems, for both clinical and research applications. These machines allow a comprehensive investigation of cardiovascular diseases, by offering a wide variety of detailed anatomical and functional data in combination. Despite significant pathophysiologic mechanisms being clarified by this new data, its clinical relevance and prognostic significance have not been demonstrated yet.


Asunto(s)
Relevancia Clínica , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones
18.
J Nucl Cardiol ; 30(6): 2289-2300, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37624562

RESUMEN

AIM: To evaluate the feasibility of retrospectively detecting and correcting periodical (cardiac and respiratory motion) and non-periodical shifts of the myocardial position (myocardial creep) using only the acquired Rubidium-82 positron emission tomography raw (listmode) data. METHODS: This study comprised 25 healthy participants (median age = 23 years) who underwent repeat rest/adenosine stress Rubidium-82 myocardial perfusion imaging (MPI) and 53 patients (median age = 64 years) considered for revascularization who underwent a single MPI session. All subjects were evaluated for myocardial creep during MPI by assessing the myocardial position every 200 ms. A proposed motion correction protocol, including corrections for cardiorespiratory and creep motion (3xMC), was compared to a guideline-recommended protocol (StandardRecon). For the volunteers, we report test-retest repeatability using standard error of measurements (SEM). For the patient cohort, we evaluated the area under the receiver operating curve (AUC) for both stress and ischemic total perfusion deficits (sTPD and iTPD, respectively) using myocardial ischemia defined as fractional flow reserve values < 0.8 in the relevant coronary segment as the gold standard. RESULTS: Test-retest repeatability was significantly improved following corrections for myocardial creep (SEM; sTPD: StandardRecon = 2.2, 3xMC = 1.8; iTPD: StandardRecon = 1.6, 3xMC = 1.2). AUC analysis of the ROC curves revealed significant improvements for iTPD measurements following 3xMC [sTPD: StandardRecon = 0.88, 3xMC = 0.92 (P = .21); iTPD: StandardRecon = 0.88, 3xMC = 0.95 (P = .039)]. CONCLUSION: 3xMC has the potential to improve the diagnostic accuracy of myocardial MPI obtained from positron emission tomography. Therefore, its use should be considered both in clinical routine and large-scale multicenter studies.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía de Emisión de Positrones/métodos , Corazón/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Radioisótopos de Rubidio , Imagen de Perfusión Miocárdica/métodos
19.
J Am Heart Assoc ; 12(12): e028767, 2023 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-37318021

RESUMEN

Background Coronary microvascular disease (CMD) may be part of a systemic small vessel disease that also manifests as neurological impairment and kidney disease. However, clinical evidence supporting a potential link is scarce. We assessed whether CMD is associated with an increased risk of small vessel disease in the kidney and brain. Methods and Results A retrospective multicenter (n=3) study of patients clinically referred to 82-rubidium positron emission tomography myocardial perfusion imaging was conducted between January 2018 and August 2020. Exclusion criterion was reversible perfusion defects >5%. CMD was defined as myocardial flow reserve (MFR) ≤2. The primary outcome, microvascular event, was defined by hospital contact for chronic kidney disease, stroke, or dementia. Among 5122 patients, 51.7% were men, median age 69.0 [interquartile range, 60.0-75.0] years, 11.0% had left ventricular ejection fraction ≤40%, and 32.4% had MFR ≤2. MFR was associated with baseline estimated glomerular filtration rate after multivariable adjustment (ß=0.04 [95% CI, 0.03-0.05]; P<0.001). During a median follow-up of 3.05 years, 383 (7.5%) patients suffered an event (253 cerebral and 130 renal), more frequently in patients with MFR ≤2 versus MFR >2 (11.6% versus 5.5%, P<0.001). MFR ≤2 was associated to outcome with a hazard ratio (HR) of 2.30 (95% CI, 1.88-2.81, P<0.001) and an adjusted HR of 1.62 (95% CI, 1.32-2.00, P<0.001). Results were consistent across subgroups defined by presence of irreversible perfusion defects, estimated glomerular filtration rate, diabetes, left ventricular ejection fraction, and previous revascularization. Conclusions This is the first large-scale cohort study to link CMD to microvascular events in the kidney and brain. Data support the hypothesis that CMD is part of a systemic vascular disorder.


Asunto(s)
Enfermedad de la Arteria Coronaria , Angina Microvascular , Imagen de Perfusión Miocárdica , Enfermedades Vasculares , Masculino , Humanos , Anciano , Femenino , Rubidio , Volumen Sistólico , Estudios de Cohortes , Imagen de Perfusión Miocárdica/métodos , Función Ventricular Izquierda , Tomografía de Emisión de Positrones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Riñón/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Circulación Coronaria
20.
J Nucl Cardiol ; 30(4): 1458-1468, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36600173

RESUMEN

BACKGROUND: Coincidental extracardiac findings with increased perfusion were reported during myocardial perfusion imaging (MPI) with various retention radiotracers. Clinical parametric O-15-H2O PET MPI yielding quantitative measures of myocardial blood flow (MBF) was recently implemented at our facility. We aim to explore whether similar extracardiac findings are observed using O-15-H2O. METHODS AND RESULTS: All patients (2963) were scanned with O-15-H2O PET MPI according to international guidelines and extracardiac findings were collected. In contrast to parametric O-15-H2O MBF images, extracardiac perfusion was assessed using summed images. Biopsy histopathology and other imaging modalities served as reference standards. Various malignant lesions with increased perfusion were detected, including lymphomas, large-celled neuroendocrine tumour, breast, and lung cancer plus metastases from colonic and renal cell carcinomas. Furthermore, inflammatory and hyperplastic benign conditions with increased perfusion were observed: rib fractures, gynecomastia, atelectasis, sarcoidosis, pneumonia, chronic lung inflammation and fibrosis, benign lung nodule, chronic diffuse lung infiltrates, pleural plaques and COVID-19 infiltrates. CONCLUSIONS: Malignant and benign extracardiac coincidental findings with increased perfusion are readily visible and frequently seen on O-15-H2O PET MPI. We recommend evaluating the summed O-15-H2O PET images in addition to the low-dose CT attenuation images.


Asunto(s)
COVID-19 , Imagen de Perfusión Miocárdica , Masculino , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Imagen de Perfusión Miocárdica/métodos , Perfusión , Tomografía de Emisión de Positrones/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA