Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Eur Heart J Case Rep ; 8(7): ytae333, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39165671

RESUMEN

Background: Mitral annular calcification (MAC) is common in the elderly. Extensive calcification has been historically challenging for the cardiac surgeons, with traditional surgical approaches carrying significant risks. Less invasive approaches have recently been explored in an attempt to reduce this risk. Case summary: We report the case of a 75-year-old woman who presented with recurrent pulmonary oedema, due to severe MAC and mitral regurgitation. Her past medical history included bioprosthetic aortic valve replacement 5 years ago. Given the extensive MAC and the patient's frailty, a minimally invasive hybrid approach with direct implantation of a transcatheter balloon expandable Sapien 3 valve was selected to manage her. Although the post-surgical result was initially excellent with elimination of the mitral regurgitation, the patient's post-operative course was marked by two serious complications, namely, acute severe aortic regurgitation, due to rupture of the bioprosthetic valve's right cusp, and severe paravalvular leak of the Sapien valve, due to posterior migration towards the left atrium. These were managed successfully with emergency valve-in-valve implantation using the 'double chimney' technique for the bioprosthetic aortic valve, as well as transeptal valve-in-valve implantation of a 2nd Sapien valve in the mitral valve, which sealed the gap between the 1st Sapien and the calcified mitral annulus. Discussion: This case illustrates a less invasive approach for the management of severe MAC. Complications can still occur in this high-risk group of patients, and therefore, such cases should be managed with close collaboration between cardiac surgeons and cardiologists, in centres with high expertise.

2.
Clin Case Rep ; 12(8): e9315, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39119032

RESUMEN

Key Clinical Message: In recent years, it is necessary to Redo-TAVR for the patients with bioprosthetic valve degeneration. This case report described a unique instance to successfully Redo-TAVR a patient with bioprosthetic valve degeneration, in addition, with left cerebral infarction and renal insufficiency. Abstract: Over time, more and more patients have bioprosthetic valve degeneration either used in SAVR or TAVR. In order to solve the produced problems due to the degenerated bioprosthetic valve, Redo-TAVR was increasingly popular due to its safe and efficiency especially for the high risk and complicated symptoms patients. In this case, the patient with left cerebral infarction and renal insufficiency has exhibited severe regurgitation and obvious neoplasm around the previous replaced aortic valve. For the patient with complicated symptoms, we did not image for this patient and only used CT to determine the position and angle for the Redo-TAVR on the base of metal stent for the previous replaced aortic valve. During the Redo-TAVR process, for fear of the obvious neoplasm slipping from the previous replaced aortic valve to embolism of important organs, before carrying out the Redo-TAVR, cerebral protection device, temporary pacemaker, and coronary artery protection device were utilized in order to avoid the damage for the important organs from the obvious neoplasm slipping from the previous replaced aortic valve. The surgery was successful and the patient recovered well. The patient's symptoms of chest tightness and suffocation have been greatly reduced.

3.
Int J Cardiol ; 414: 132394, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-39067525

RESUMEN

BACKGROUND: Prevalence of bioprosthetic valve degeneration (BVD) is rising as the use of bioprosthetic aortic valves increases. Detecting early signs of BVD remains a challenge, with conventional imaging methods often failing to identify early deterioration stages. 18F-fuoride positron emission tomography (PET-CT) is an emerging technique that offers promising prospects to detect subclinical BVD. This study aimed to compare early PET parameters of fluoride uptake with echocardiographic hemodynamic parameters and compare outcomes according to anticoagulation in patients who received bioprosthetic valves. METHODS: This is a sub-study of the ANTIPRO clinical trial, which involved patients undergoing surgical aortic valve replacement (SAVR) with a porcine bioprosthesis and randomized them into anticoagulated and non-anticoagulated groups. Hemodynamic changes were assessed by transthoracic echocardiography (TTE), while 18F-fluoride PET-CT quantified fluoride uptake and divided the patients in two groups: high-uptake and low-uptake. Mean and maximum gradients by TTE at three years were compared between the two uptake groups. Fluoride uptake was also compared between the anticoagulated and control groups. RESULTS: We found no significant differences in transprosthetic gradients between high-uptake(21.4 ± 8.6 mmHg) and low-uptake(17.3 ± 11.2 mmHg.p = 0.244) PET-defined groups in this specific timeframe. Notably, anticoagulated patients exhibited significantly risk of higher fluoride uptake(OR = 4.34;95%CI:1.04-18.21.p = 0.045). CONCLUSIONS: No association was found between fluoride uptake and hemodynamic evaluation. Anticoagulation was associated with higher fluoride uptake. These findings highlight the emerging role of PET-CT in studying bioprosthetic aortic valves and emphasize the need for extended follow-up to evaluate the impact of anticoagulation on valve degeneration.


Asunto(s)
Anticoagulantes , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Warfarina , Bioprótesis/efectos adversos , Humanos , Femenino , Masculino , Prótesis Valvulares Cardíacas/efectos adversos , Anticoagulantes/administración & dosificación , Anciano , Warfarina/administración & dosificación , Warfarina/farmacocinética , Warfarina/uso terapéutico , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Radioisótopos de Flúor , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Persona de Mediana Edad , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estudios de Seguimiento , Falla de Prótesis , Tomografía de Emisión de Positrones/métodos
4.
JACC Case Rep ; 29(3): 102197, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38361555

RESUMEN

A 38-year-old pregnant patient was managed by the cardio-obstetrics multidisciplinary team for severe degenerative bioprosthetic aortic valve failure. She was medically managed utilizing echocardiogram and brain natriuretic peptide until she demonstrated worsening heart failure. A valve and cardio-obstetrics team evaluation led to valve-in-valve transcatheter aortic valve replacement at 30 weeks' gestation.

5.
Am J Cardiol ; 214: 8-17, 2024 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-38104756

RESUMEN

This study aimed to evaluate the incidence and clinical implications of myocardial injury, as determined by cardiac biomarker increase, in patients who underwent mitral bioprosthesis dysfunction treatment with transcatheter mitral valve replacement (TMVR) versus surgical mitral valve replacement reoperation (SMVR-REDO). Between 2014 and 2023, 310 patients with mitral bioprosthesis failure were included (90 and 220 patients for TMVR and SMVR-REDO, respectively). Multivariable analysis and propensity score matching were performed to adjust for the intergroup differences in baseline characteristics. Creatinine kinase-MB (CK-MB) and cardiac troponin I (cTn) were collected at baseline and 6 to 12, 24, 48, and 72 hours after intervention. The cardiac biomarkers values were evaluated in relation to their reference values. The outcomes were determined according to the Mitral Valve Academic Research Consortium criteria. CK-MB and cTn increased above the reference level in almost all patients after SMVR-REDO and TMVR (100% vs 94%, respectively), with the peak occurring within 6 to 12 hours. SMVR-REDO was associated with a two- to threefold higher increase in cardiac biomarkers. After 30 days, the mortality rates were 13.3% in the TMVR and 16.8% in the SMVR-REDO groups. At a median follow-up of 19 months, the mortality rates were 21.1% in the TMVR and 17.7% in the SMVR-REDO groups. Left ventricular ejection fraction, estimated glomerular filtration rate, CK-MB, and cTn were predictors of mortality. In conclusion, some degree of myocardial injury occurred systematically after the treatment of mitral bioprosthetic degeneration, especially after SMVR, and higher CK-MB and cTn levels were associated with increased cumulative late mortality, regardless of the approach.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/cirugía , Reoperación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Volumen Sistólico , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Resultado del Tratamiento , Función Ventricular Izquierda , Enfermedades de las Válvulas Cardíacas/cirugía , Biomarcadores , Cateterismo Cardíaco/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos
6.
Eur Heart J Cardiovasc Imaging ; 24(12): 1690-1699, 2023 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-37409985

RESUMEN

AIMS: Remnant cholesterol (RC) seems associated with native aortic stenosis. Bioprosthetic valve degeneration may share similar lipid-mediated pathways with aortic stenosis. We aimed to investigate the association of RC with the progression of bioprosthetic aortic valve degeneration and ensuing clinical outcomes. METHODS AND RESULTS: We enrolled 203 patients with a median of 7.0 years (interquartile range: 5.1-9.2) after surgical aortic valve replacement. RC concentration was dichotomized by the top RC tertile (23.7 mg/dL). At 3-year follow-up, 121 patients underwent follow-up visit for the assessment of annualized change in aortic valve calcium density (AVCd). RC levels showed a curvilinear relationship with an annualized progression rate of AVCd, with increased progression rates when RC >23.7 mg/dL (P = 0.008). There were 99 deaths and 46 aortic valve re-interventions in 133 patients during a median clinical follow-up of 8.8 (8.7-9.6) years. RC >23.7 mg/dL was independently associated with mortality or re-intervention (hazard ratio: 1.98; 95% confidence interval: 1.31-2.99; P = 0.001). CONCLUSION: Elevated RC is independently associated with faster progression of bioprosthetic valve degeneration and increased risk of all-cause mortality or aortic valve re-intervention.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Falla de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Colesterol , Bioprótesis/efectos adversos , Resultado del Tratamiento
7.
J Clin Med ; 12(14)2023 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-37510906

RESUMEN

Within the last two decades, transcatheter aortic valve replacement (TAVR) has transformed the treatment strategy for symptomatic severe aortic stenosis (AS), representing a less invasive alternative to traditional open-chest surgery. With time, advances in device features, imaging planning, and implantation techniques have contributed to an improvement in safety as well as a reduction in procedural complications. This has led to the expansion of TAVR to lower-risk patients, where TAVR has shown favorable outcomes compared to surgical aortic valve replacement (SAVR). As TAVR expands to younger and lower-risk patients with longer life expectancies, the need for reintervention for failing transcatheter heart valves is expected to increase. Redo-TAVR has gained increasing relevance in the lifetime management of AS as one of the treatment strategies available for structural valve dysfunction (SVD). However, some issues are associated with this approach, including coronary re-access and the risk of coronary obstruction. In this review, we provide essential concepts to properly select candidates for Redo-TAVR, updated data on clinical outcomes and complication rates, and current gaps in evidence.

8.
JACC Case Rep ; 4(9): 551-555, 2022 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-35573851

RESUMEN

We present the first in-human transcatheter systemic atrioventricular valve-in-valve implantation in a 37-year-old patient with Ebstein anomaly, levo-transposition of the great arteries, and prior systemic valve replacement. She had severe bioprosthetic valve regurgitation and reduced systolic function. She had high surgical risk and was planned for transcatheter intervention. (Level of Difficulty: Advanced.).

9.
Intern Emerg Med ; 16(7): 1873-1882, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33770370

RESUMEN

A little is known about long-term hemodynamic performance of the transcatheter heart valves (THVs). The aim of the present study was to assess hemodynamic outcome, structural valve deterioration (SVD) and bioprosthetic valve failure (BVF) in patients treated with transcatheter aortic valve replacement (TAVR) five or more years ago. All consecutive patients treated at Bologna and Florence University Hospitals with TAVR between January 2008 and December 2013 were analyzed in a retrospective registry with regards to demographic, procedural and outcome data as well as follow-up data on mortality and echocardiographic characteristics. Standardized definitions were used to define outcomes and durability of the THVs. 400 patients were included in the study, mostly treated with transfemoral TAVR (71.8%), using first generation balloon-expandable (37%) or self-expanding (63%) devices. The 1-year mortality was 21.8% (87 patients) and 5-year mortality was 53.8% (215 patients). Median follow-up was 45.5 months (14.0-68.9) totaling 1516.7 patient/years, with the longest follow-up being 10.25 years. At least one follow-up echocardiogram was available for 320 patients (80%), SVD occurred in 19 of these patients (5.94%): moderate in 17 patients (5.31%) and severe in two patients (0.63%). The hemodynamic presentation was stenosis in most of the cases (12 patients). Late BVF was registered in 10 patients (3.13%) and this was mainly driven by transcatheter paravalvular leak closure (six patients) with subsequent good long-term outcome. Our results confirm that TAVR appears to be a long-lasting treatment strategy with low rates of structural valve degeneration and valve failure.


Asunto(s)
Ecocardiografía , Evaluación de Resultado en la Atención de Salud/métodos , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino
10.
J Am Coll Cardiol ; 73(10): 1107-1119, 2019 03 19.
Artículo en Inglés | MEDLINE | ID: mdl-30871693

RESUMEN

BACKGROUND: Bioprosthetic aortic valve degeneration is increasingly common, often unheralded, and can have catastrophic consequences. OBJECTIVES: The authors sought to assess whether 18F-fluoride positron emission tomography (PET)-computed tomography (CT) can detect bioprosthetic aortic valve degeneration and predict valve dysfunction. METHODS: Explanted degenerate bioprosthetic valves were examined ex vivo. Patients with bioprosthetic aortic valves were recruited into 2 cohorts with and without prosthetic valve dysfunction and underwent in vivo contrast-enhanced CT angiography, 18F-fluoride PET, and serial echocardiography during 2 years of follow-up. RESULTS: All ex vivo, degenerate bioprosthetic valves displayed 18F-fluoride PET uptake that colocalized with tissue degeneration on histology. In 71 patients without known bioprosthesis dysfunction, 14 had abnormal leaflet pathology on CT, and 24 demonstrated 18F-fluoride PET uptake (target-to-background ratio 1.55 [interquartile range (IQR): 1.44 to 1.88]). Patients with increased 18F-fluoride uptake exhibited more rapid deterioration in valve function compared with those without (annualized change in peak transvalvular velocity 0.30 [IQR: 0.13 to 0.61] vs. 0.01 [IQR: -0.05 to 0.16] ms-1/year; p < 0.001). Indeed 18F-fluoride uptake correlated with deterioration in all the conventional echocardiographic measures of valve function assessed (e.g., change in peak velocity, r = 0.72; p < 0.001). Each of the 10 patients who developed new overt bioprosthesis dysfunction during follow-up had evidence of 18F-fluoride uptake at baseline (target-to-background ratio 1.89 [IQR: 1.46 to 2.59]). On multivariable analysis, 18F-fluoride uptake was the only independent predictor of future bioprosthetic dysfunction. CONCLUSIONS: 18F-fluoride PET-CT identifies subclinical bioprosthetic valve degeneration, providing powerful prediction of subsequent valvular dysfunction and highlighting patients at risk of valve failure. This technique holds major promise in the diagnosis of valvular degeneration and the surveillance of patients with bioprosthetic valves. (18F-Fluoride Assessment of Aortic Bioprosthesis Durability and Outcome [18F-FAABULOUS]; NCT02304276).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Complicaciones Posoperatorias , Falla de Prótesis/efectos adversos , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico , Calcinosis/diagnóstico , Calcinosis/etiología , Angiografía por Tomografía Computarizada/métodos , Ecocardiografía/métodos , Femenino , Fluorodesoxiglucosa F18/farmacología , Humanos , Masculino , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Valor Predictivo de las Pruebas , Pronóstico , Radiofármacos/farmacología
12.
Echocardiography ; 35(4): 501-505, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29570849

RESUMEN

We demonstrate the usefulness of two- and live/real time three-dimensional transesophageal echocardiography in a procedure, which combined transcatheter mitral valve-in-valve deployment and paraprosthetic leak closure in the same setting using the less invasive transfemoral approach in an adult patient with bioprosthetic mitral valve degeneration. We also highlight the additive value of three-dimensional echocardiography over the two-dimensional technique.


Asunto(s)
Ecocardiografía Transesofágica/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Falla de Prótesis , Anciano de 80 o más Años , Ecocardiografía Tridimensional , Prótesis Valvulares Cardíacas , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA