Sci Rep ; 14(1): 18960, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39147875

RESUMEN

While magnetomyography (MMG) using optically pumped magnetometers (OPMs) is a promising method for non-invasive investigation of the neuromuscular system, it has almost exclusively been performed in magnetically shielded rooms (MSRs) to date. MSRs provide extraordinary conditions for biomagnetic measurements but limit the widespread adoption of measurement methods due to high costs and extensive infrastructure. In this work, we address this issue by exploring the feasibility of mobile OPM-MMG in a setup of commercially available components. From field mapping and simulations, we find that the employed zero-field OPM can operate within a large region of the mobile shield, beyond which residual magnetic fields and perturbations become increasingly intolerable. Moreover, with digital filtering and moderate averaging a signal quality comparable to that in a heavily shielded MSR is attained. These findings facilitate practical and cost-effective implementations of OPM-MMG systems in clinical practice and research.

2.
Magn Reson Med ; 92(5): 1965-1979, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38934418

RESUMEN

PURPOSE: There is a need for high resolution non-invasive imaging methods of physiologic magnetic fields. The purpose of this work is to develop a MRI detection approach for non-sinusoidal magnetic fields based on the rotary excitation (REX) mechanism which was previously successfully applied for the detection of oscillating magnetic fields in the sub-nT range. METHODS: The new detection concept was examined by means of Bloch simulations, evaluating the interaction effect of spin-locked magnetization and low-frequency pulsed magnetic fields. The REX detection approach was validated under controlled conditions in phantom experiments at 3 T. Gaussian and sinc-shaped stimuli were investigated. In addition, the detection of artificial fields resembling a cardiac QRS complex, which is the most prominent peak visible on a magnetocardiogram, was tested. RESULTS: Bloch simulations demonstrated that the REX method has a high sensitivity to pulsed fields in the resonance case, which is met when the spin-lock frequency coincides with a non-zero Fourier component of the stimulus field. In the experiments, we found that magnetic stimuli of different durations and waveforms can be distinguished by their characteristic REX response spectrum. The detected REX amplitude was proportional to the stimulus peak amplitude (R2 > 0.98) and the lowest field detection was 1 nT. Furthermore, the detection of QRS-like fields with varying QRS durations yielded significant results in a phantom setup (p < 0.001). CONCLUSION: REX detection can be transferred to non-sinusoidal pulsed magnetic fields and could provide a non-invasive, quantitative tool for spatially resolved assessment of cardiac biomagnetism. Potential applications include the direct detection and characterization of cardiac conduction.


Asunto(s)
Sistema de Conducción Cardíaco , Campos Magnéticos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Humanos , Imagen por Resonancia Magnética/métodos , Sistema de Conducción Cardíaco/diagnóstico por imagen , Algoritmos , Simulación por Computador , Reproducibilidad de los Resultados , Magnetocardiografía/métodos , Sensibilidad y Especificidad
3.
Exp Biol Med (Maywood) ; 249: 10037, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38854792

RESUMEN

In-ovo imaging using avian eggs has been described as a potential alternative to animal testing using rodents. However, imaging studies are hampered by embryonal motion producing artifacts. This study aims at systematically comparing isoflurane, desflurane and sevoflurane in three different concentrations in ostrich embryos. Biomagnetic signals of ostrich embryos were recorded analyzing cardiac action and motion. Ten groups comprising eight ostrich embryos each were investigated: Control, isoflurane (2%, 4%, and 6%), desflurane (6%, 12%, and 18%) and sevoflurane (3%, 5%, and 8%). Each ostrich egg was exposed to the same narcotic gas and concentration on development day (DD) 31 and 34. Narcotic gas exposure was upheld for 90 min and embryos were monitored for additional 75 min. Toxicity was evaluated by verifying embryo viability 24 h after the experiments. Initial heart rate of mean 148 beats/min (DD 31) and 136 beats/min (DD 34) decreased over time by 44-48 beats/minute. No significant differences were observed between groups. All narcotic gases led to distinct movement reduction after mean 8 min. Embryos exposed to desflurane 6% showed residual movements. Isoflurane 6% and sevoflurane 8% produced motion-free time intervals of mean 70 min after discontinuation of narcotic gas exposure. Only one embryo death occurred after narcotic gas exposure with desflurane 6%. This study shows that isoflurane, desflurane and sevoflurane are suitable for ostrich embryo immobilization, which is a prerequisite for motion-artifact free imaging. Application of isoflurane 6% and sevoflurane 8% is a) safe as no embryonal deaths occurred after exposure and b) effective as immobilization was observed for approx. 70 min after the end of narcotic gas exposure. These results should be interpreted with caution regarding transferability to other avian species as differences in embryo size and incubation duration exist.


Asunto(s)
Desflurano , Embrión no Mamífero , Isoflurano , Struthioniformes , Animales , Struthioniformes/embriología , Embrión no Mamífero/efectos de los fármacos , Anestésicos por Inhalación , Sevoflurano/efectos adversos , Sevoflurano/farmacología , Narcóticos/toxicidad , Inmovilización
4.
Med Eng Phys ; 128: 104175, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38789219

RESUMEN

OBJECTIVE: To record and extract features of fetal cardiac activities with a semi-rigid prototype optically-pumped magnetometers (OPM) sensor array. METHODS: Fetal magnetocardiography (fMCG) data were collected from 15 pregnant women between 28 and 40 weeks gestation. Mothers were lying flat in a customized bed with sensors touching their abdomen from below using a prototype grid. fMCG was extracted to perform standard fetal heart rate variability (FHRV) analysis. RESULTS: fMCG was observed in 13 of the 15 pregnant women. OPM FHRV indicators were in the range of previous SQUID studies. CONCLUSION: Semi-rigid prototype OPM system has the ability to record quality fMCG. fMCG is capable of identifying lethal cardiac rhythm disturbances in the fetus. Our novel application of OPM technology may lower costs and increase maternal comfort, thus expanding fMCG's generalizability.


Asunto(s)
Magnetocardiografía , Humanos , Magnetocardiografía/instrumentación , Magnetocardiografía/métodos , Femenino , Embarazo , Adulto , Frecuencia Cardíaca Fetal , Feto/fisiología , Fenómenos Ópticos , Dispositivos Ópticos
5.
Front Med Technol ; 6: 1351905, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38690583

RESUMEN

We are engaged in the development and clinical application of a neural magnetic field measurement system that utilizes biomagnetic measurements to observe the activity of the spinal cord and peripheral nerves. Unlike conventional surface potential measurements, biomagnetic measurements are not affected by the conductivity distribution within the body, making them less influenced by the anatomical structure of body tissues. Consequently, functional testing using biomagnetic measurements can achieve higher spatial resolution compared to surface potential measurements. The neural magnetic field measurement, referred to as magnetoneurography, takes advantage of these benefits to enable functional testing of the spinal cord and peripheral nerves, while maintaining high spatial resolution and noninvasiveness. Our magnetoneurograph system is based on superconducting quantum interference devices (SQUIDs) similar to the conventional biomagnetic measurement systems. Various design considerations have been incorporated into the SQUID sensor array structure and signal processing software to make it suitable for detecting neural signal propagation along spinal cord and peripheral nerve. The technical validation of this system began in 1999 with a 3-channel SQUID system. Over the course of more than 20 years, we have continued technological development through medical-engineering collaboration, and in the latest prototype released in 2020, neural function imaging of the spinal cord and peripheral nerves, which could also be applied for the diagnosis of neurological disorders, has become possible. This paper provides an overview of the technical aspects of the magnetoneurograph system, covering the measurement hardware and software perspectives for providing diagnostic information, and its applications. Additionally, we discuss the integration with a helium recondensing system, which is a key factor in reducing running costs and achieving practicality in hospitals.

6.
Bioengineering (Basel) ; 10(12)2023 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-38136023

RESUMEN

Electroanatomical mapping is a method for creating a model of the electrophysiology of the human heart. Medical professionals routinely locate and ablate the site of origin of cardiac arrhythmias with invasive catheterization. Non-invasive localization takes the form of electrocardiographic (ECG) or magnetocardiographic (MCG) imaging, where the goal is to reconstruct the electrical activity of the human heart. Non-invasive alternatives to catheter electroanatomical mapping would reduce patients' risks and open new venues for treatment planning and prevention. This work introduces a new system state-based method for estimating the electrical activity of the human heart from MCG measurements. Our model enables arbitrary propagation paths and velocities. A Kalman filter optimally estimates the current densities under the given measurements and model parameters. In an outer optimization loop, these model parameters are then optimized via gradient descent. This paper aims to establish the foundation for future research by providing a detailed mathematical explanation of the algorithm. We demonstrate the feasibility of our method through a simplified one-layer simulation. Our results show that the algorithm can learn the propagation paths from the magnetic measurements. A threshold-based segmentation into healthy and pathological tissue yields a DICE score of 0.84, a recall of 0.77, and a precision of 0.93.

7.
Sci Total Environ ; 905: 167808, 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-37838055

RESUMEN

Green infrastructure (GI) is already known to be a suitable way to enhance air quality in urban environments. Living wall systems (LWS) can be implemented in locations where other forms of GI, such as trees or hedges, are not suitable. However, much debate remains about the variables that influence their particulate matter (PM) accumulation efficiency. This study attempts to clarify which plant species are relatively the most efficient in capturing PM and which traits are decisive when it comes to the implementation of a LWS. We investigated 11 plant species commonly used on living walls, located close to train tracks and roads. PM accumulation on leaves was quantified by magnetic analysis (Saturation Isothermal Remanent Magnetization (SIRM)). Several leaf morphological variables that could potentially influence PM capture were assessed, as well as the Wall Leaf Area Index. A wide range in SIRM values (2.74-417 µA) was found between all species. Differences in SIRM could be attributed to one of the morphological parameters, namely SLA (specific leaf area). This suggest that by just assessing SLA, one can estimate the PM capture efficiency of a plant species, which is extremely interesting for urban greeners. Regarding temporal variation, some species accumulated PM over the growing season, while others actually decreased in PM levels. This decrease can be attributed to rapid leaf expansion and variations in meteorology. Correct assessment of leaf age is important here; we suggest individual labeling of leaves for further studies. Highest SIRM values were found close to ground level. This suggests that, when traffic is the main pollution source, it is most effective when LWS are applied at ground level. We conclude that LWS can act as local sinks for PM, provided that species are selected correctly and systems are applied according to the state of the art.


Asunto(s)
Contaminantes Atmosféricos , Material Particulado , Material Particulado/análisis , Contaminantes Atmosféricos/análisis , Estaciones del Año , Monitoreo del Ambiente , Plantas , Árboles/química , Hojas de la Planta/química
8.
Comput Biol Med ; 165: 107384, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37633085

RESUMEN

Gastric motility is coordinated by bioelectric slow waves (SWs) and dysrhythmic SW activity has been linked with motility disorders. Magnetogastrography (MGG) is the non-invasive measurement of the biomagnetic fields generated by SWs. Dysrhythmia identification using MGG is currently challenging because source models are not well developed and the impact of anatomical variation is not well understood. A novel method for the quantitative spatial co-registration of serosal SW potentials, MGG, and geometric models of anatomical structures was developed and performed on two anesthetized pigs to verify feasibility. Electrode arrays were localized using electromagnetic transmitting coils. Coil localization error for the volume where the stomach is normally located under the sensor array was assessed in a benchtop experiment, and mean error was 4.2±2.3mm and 3.6±3.3° for a coil orientation parallel to the sensor array and 6.2±5.7mm and 4.5±7.0° for a perpendicular coil orientation. Stomach geometries were reconstructed by fitting a generic stomach to up to 19 localization coils, and SW activation maps were mapped onto the reconstructed geometries using the registered positions of 128 electrodes. Normal proximal-to-distal and ectopic SW propagation patterns were recorded from the serosa and compared against the simultaneous MGG measurements. Correlations between the center-of-gravity of normalized MGG and the mean position of SW activity on the serosa were 0.36 and 0.85 for the ectopic and normal propagation patterns along the proximal-distal stomach axis, respectively. This study presents the first feasible method for the spatial co-registration of MGG, serosal SW measurements, and subject-specific anatomy. This is a significant advancement because these data enable the development and validation of novel non-invasive gastric source characterization methods.


Asunto(s)
Motilidad Gastrointestinal , Estómago , Animales , Porcinos , Motilidad Gastrointestinal/fisiología , Estómago/fisiología , Fenómenos Electrofisiológicos/fisiología , Electrodos , Abdomen
9.
Sensors (Basel) ; 23(9)2023 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-37177427

RESUMEN

Biomagnetism is the measurement of the weak magnetic fields produced by nerves and muscle. The magnetic field of the heart-the magnetocardiogram (MCG)-is the largest biomagnetic signal generated by the body and was the first measured. Magnetic fields have been detected from isolated tissue, such as a peripheral nerve or cardiac muscle, and these studies have provided insights into the fundamental properties of biomagnetism. The magnetic field of the brain-the magnetoencephalogram (MEG)-has generated much interest and has potential clinical applications to epilepsy, migraine, and psychiatric disorders. The biomagnetic inverse problem, calculating the electrical sources inside the brain from magnetic field recordings made outside the head, is difficult, but several techniques have been introduced to solve it. Traditionally, biomagnetic fields are recorded using superconducting quantum interference device (SQUID) magnetometers, but recently, new sensors have been developed that allow magnetic measurements without the cryogenic technology required for SQUIDs.


Asunto(s)
Corazón , Magnetoencefalografía , Humanos , Corazón/fisiología , Encéfalo/fisiología , Campos Magnéticos , Miocardio
10.
Skin Res Technol ; 29(3): e13281, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36973979

RESUMEN

BACKGROUND: Persons with cosmetic tattoos occasionally experience severe pain and burning sensation on magnetic resonance imaging (MRI). OBJECTIVE: To explore the culprit magnetic substances in commonly used permanent makeup inks. MATERIAL AND METHODS: 20 inks used for cosmetic tattooing of eyebrows, eyeliners, and lips were selected. Ink bottles were tested for magnetic behavior with a neodymium magnet. Eight iron oxide inks qualified for the final study. Metals were analyzed by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The magnetic fraction of inks was isolated and analyzed by X-ray fluorescence (XRF). Magnetic iron compounds were characterized by Mössbauer spectroscopy and powder X-ray diffraction (XRD). RESULTS: ICP-MS showed iron in all magnetic samples, and some nickel and chromium. Mössbauer spectroscopy and XRD detected ferromagnetic minerals, particularly magnetite, followed by goethite and hematite. CONCLUSION: This original study of cosmetic ink stock products made with iron oxide pigments reports magnetic impurities in inks for cosmetic tattooing, e.g., magnetite, goethite, and hematite. These may be the main cause of MRI burn sensation in cosmetic tattoos. The mechanism behind sensations is hypothesized to be induction of electrical stimuli of axons from periaxonal pigment/impurity activated by magnetic force. Magnetite is considered the lead culprit.


Asunto(s)
Quemaduras , Tatuaje , Humanos , Tatuaje/efectos adversos , Óxido Ferrosoférrico , Tinta , Minerales , Imagen por Resonancia Magnética , Sensación , Colorantes/química
11.
Sensors (Basel) ; 23(3)2023 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-36772381

RESUMEN

Magnetic resonance provides exquisite anatomical images and functional MRI monitors physiological activity by recording blood oxygenation. This review attempts to answer the following question: Can MRI be used as a sensor to directly record neural behavior? It considers MRI sensing of electrical activity in the heart and in peripheral nerves before turning to the central topic: recording of brain activity. The primary hypothesis is that bioelectric current produced by a nerve or muscle creates a magnetic field that influences the magnetic resonance signal, although other mechanisms for detection are also considered. Recent studies have provided evidence that using MRI to sense neural activity is possible under ideal conditions. Whether it can be used routinely to provide functional information about brain processes in people remains an open question. The review concludes with a survey of artificial intelligence techniques that have been applied to functional MRI and may be appropriate for MRI sensing of neural activity.


Asunto(s)
Inteligencia Artificial , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Nervios Periféricos , Campos Magnéticos
12.
Prog Biophys Mol Biol ; 177: 14-23, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36240898

RESUMEN

With the widespread use of static magnetic fields (SMFs) in medicine, it is imperative to explore the biological effects of SMFs and the mechanisms underlying their effects on biological systems. The presence of magnetic materials within cells and organisms could affect various biological metabolism and processes, including stress responses, proliferation, and structural alignment. SMFs were generally found to be safe at the organ and organism levels. However. human subjects exposed to strong SMFs have reported side effects. In this review, we combined the magnetic properties of biological samples to illustrate the mechanism of action of SMFs on biological systems from a biophysical point of view. We suggest that the mechanisms of action of SMFs on biological systems mainly include the induction of electric fields and currents, generation of magnetic effects, and influence of electron spins. An electrolyte flowing in a static magnetic field generates an induced current and an electric field. Magnetomechanical effects include orientation effects upon subjecting biological samples to SMFs and movement of biological samples in strong field gradients. SMFs are thought to affect biochemical reaction rates and yields by influencing electron spin. This paper helps people how can harness the favorable biological effects of SMFs.


Asunto(s)
Campos Magnéticos , Humanos , Biofisica
13.
Trends Neurosci ; 45(8): 621-634, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35779970

RESUMEN

Magnetoencephalography (MEG) measures human brain function via assessment of the magnetic fields generated by electrical activity in neurons. Despite providing high-quality spatiotemporal maps of electrophysiological activity, current MEG instrumentation is limited by cumbersome field sensing technologies, resulting in major barriers to utility. Here, we review a new generation of MEG technology that is beginning to lift many of these barriers. By exploiting quantum sensors, known as optically pumped magnetometers (OPMs), 'OPM-MEG' has the potential to dramatically outperform the current state of the art, promising enhanced data quality (better sensitivity and spatial resolution), adaptability to any head size/shape (from babies to adults), motion robustness (participants can move freely during scanning), and a less complex imaging platform (without reliance on cryogenics). We discuss the current state of this emerging technique and describe its far-reaching implications for neuroscience.


Asunto(s)
Neuroimagen Funcional , Magnetoencefalografía , Adulto , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Humanos , Magnetoencefalografía/métodos
14.
Exp Biol Med (Maywood) ; 247(12): 996-1004, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35466741

RESUMEN

In-ovo imaging using ostrich eggs has been described as a potential alternative to common animal testing. The main advantage is its independence from small animal imaging devices as ostrich eggs provide good image quality on regular CT, MRI, or PET used in examinations of humans. However, embryonal motion during dynamic imaging studies produce artifacts. The aims of this study were (1) to explore the feasibility of biomagnetism to detect cardiac signals and embryonal motion and to use these findings (2) to investigate the effect of isoflurane anesthesia on ostrich embryos. A standard magnetoencephalography developed for brain studies was used to detect embryonal signals of ostrich eggs on developmental day 34. Signals were instantly shown on a screen and data were also postprocessed. For assessing the effects of anesthesia, nine ostrich eggs were investigated using isoflurane 6% for 90 min. Biomagnetic signals were recorded simultaneously. A control group consisting of eight different ostrich eggs was also investigated. Cardiac signals similar to electrocardiography were observed in all eggs. Postprocessing revealed frequent motion of embryos without anesthesia. The exposure to isoflurane led to a significant decrease in motion signals in 9/9 ostrich embryos after 8 min. Motion was significantly reduced in the isoflurane group versus control group. There were no isoflurane-related deaths. This study shows that biomagnetism is feasible to detect cardiac signals and motion of ostrich embryos in-ovo. Application of isoflurane is safe and leads to a rapid decrease in embryonal motion, which is an important prerequisite for the implementation of in-ovo imaging using ostrich eggs.


Asunto(s)
Struthioniformes , Animales , Artefactos , Diagnóstico por Imagen , Huevos , Movimiento (Física)
15.
IEEE J Transl Eng Health Med ; 10: 1800106, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34950538

RESUMEN

Objective: To record and characterize features of levator ani muscles (LAM) activity in pregnancy and postpartum using non-invasive and novel Magnetomyography (MMG) technique with amplitude and spectral parameters. Methods: Nulliparous women with uncomplicated pregnancies participated in the MMG data collection during rest and voluntary LAM contractions (Kegels) with modulated intensity in third trimester and approximately 2 months postpartum (PP). Simultaneous surface electromyography was recorded to document the recruitment of accessory muscles. Moderate strength Kegel (MK) MMG trials were analyzed. Amplitude and spectral parameters including root-mean square (RMS) amplitude, power spectrum density (PSD) and normalized PSD (rPSD) in three frequency bands (low, middle, high) were computed on MK epochs. Statistical comparisons between pregnancy and postpartum were calculated. Results: MMG recordings were measured from 10 pregnant women. Results showed decreased RMS and power between third trimester and postpartum, trending towards significance. rPSD values in the low frequency band decreased significantly (p = 0.028) from third trimester to postpartum, while significant increase was observed in the middle frequency band (p = 0.018). Conclusions: This study shows that MMG as non-invasive tool has the ability to detect and characterize changes of LAM activity with amplitude and spectral parameters during pregnancy and postpartum.


Asunto(s)
Enfermedades Musculares , Diafragma Pélvico , Electromiografía , Femenino , Humanos , Contracción Muscular/fisiología , Periodo Posparto/fisiología , Embarazo
16.
Comput Biol Med ; 129: 104169, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33338892

RESUMEN

Magnetogastrography (MGG) is a non-invasive method of assessing gastric slow waves (SWs) by recording the resultant magnetic fields. MGG can capture both SW frequency and propagation, and identify SW dysrhythmias that are associated with motility disorders. However, the impact of the restricted spatial coverage and sensor density on SW propagation tracking performance is unknown. This study simulated MGG using multiple anatomically specific torso geometries and two realistic SW propagation patterns to determine the effect of different sensor configurations on tracking SW propagation. The surface current density mapping and center-of-gravity tracking methods were used to compare four magnetometer array configurations: a reference system currently used in GI research and three hypothetical higher density and coverage arrays. SW propagation patterns identified with two hypothetical arrays (with coverage over at least the anterior of the torso) correlated significantly higher with simulated realistic 3 cycle-per-minute SW activity than the reference array (p = 0.016, p = 0.005). Furthermore, results indicated that most of the magnetic fields that contribute to the performance of SW propagation tracking were located on the anterior of the torso as further increasing the coverage did not significantly increase performance. A 30% decrease in sensor spacing within the same spatial coverage of the reference array also significantly increased correlation values by approximately 0.50 when the signal-to-noise ratio was 5 dB. This study provides evidence that higher density and coverage sensor layouts will improve the utility of MGG. Further work is required to investigate optimum sensor configurations across larger anatomical variations and other SW propagation patterns.


Asunto(s)
Motilidad Gastrointestinal , Estómago , Campos Magnéticos , Microcirugia , Relación Señal-Ruido , Estómago/diagnóstico por imagen
17.
Sensors (Basel) ; 20(16)2020 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-32823964

RESUMEN

Magnetography with superconducting quantum interference device (SQUID) sensor arrays is a well-established technique for measuring subtle magnetic fields generated by physiological phenomena in the human body. Unfortunately, the SQUID-based systems have some limitations related to the need to cool them down with liquid helium. The room-temperature alternatives for SQUIDs are optically pumped magnetometers (OPM) operating in spin exchange relaxation-free (SERF) regime, which require a very low ambient magnetic field. The most common two-layer magnetically shielded rooms (MSR) with residual magnetic field of 50 nT may not be sufficiently magnetically attenuated and additional compensation of external magnetic field is required. A cost-efficient compensation system based on square Helmholtz coils was designed and successfully used for preliminary measurements with commercially available zero-field OPM. The presented setup can reduce the static ambient magnetic field inside a magnetically shielded room, which improves the usability of OPMs by providing a proper environment for them to operate, independent of initial conditions in MSR.


Asunto(s)
Campos Magnéticos , Magnetometría/instrumentación , Humanos , Magnetoencefalografía
18.
Nanomedicine (Lond) ; 15(5): 511-525, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-32077357

RESUMEN

Aim: This paper aims to investigate a doxorubicin (DOX) chronic kidney disease rat model using magnetic nanoparticles (MNPs) associated with the alternate current biosusceptometry (ACB) to analyze its different perfusion profiles in both healthy and DOX-injured kidneys. Materials & methods: We used the ACB to detect the MNP kidney perfusion in vivo. Furthermore, we performed biochemical and histological analyses, which sustained results obtained from the ACB system. We also studied the MNP biodistribution. Results: We found that DOX kidney injury alters the MNPs' kidney perfusion. These changes became more intense as the disease progressed. Moreover, DOX has an important effect on MNP biodistribution as the disease evolved. Conclusion: This study provides new applications of MNPs in nephrology, instrumentation, pharmacology, physiology and nanomedicine.


Asunto(s)
Doxorrubicina/efectos adversos , Riñón/efectos de los fármacos , Nanopartículas de Magnetita , Animales , Riñón/fisiopatología , Ratas , Distribución Tisular
19.
Healthc Technol Lett ; 6(3): 70-75, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31341631

RESUMEN

This work proposes and computationally investigate the use of magnetic neural stimulation as an alternative to electrical stimulation to achieve selective activation of rat sciatic nerve. In particular, they assess the effectiveness of an array of small coils to obtain selective neural stimulation, as compared to a single coil. Specifically, an array of four mm-sized coils is used to stimulate rat sciatic nerve, targeting the regions of fascicles that are associated with different muscles of the leg. To evaluate the selectivity of activation, a three-dimensional heterogeneous multi-resolution nerve model is implemented using the impedance method for the computation of the magnetic and electric fields in the nerve. The performance metric 'selectivity index' is defined that measures the recruitment of the targeted region compared to other non-targeted regions of the nerve. The selectivity index takes values between -1 (least selective) and 1 (most selective). For each targeted region, a selectivity index of 0.75 or better is predicted for the proposed array configuration. The results suggest that an array of coils can provide superior spatial control of the electric field induced in the neural tissue compared to traditional extraneural electrode arrays, thus opening the possibility to applications where selective neurostimulation is of interest.

20.
Med Devices Sens ; 1(1)2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30643870

RESUMEN

Iron plays a vital role in human body. Liver Iron Concentration (LIC) is directly correlated to total body iron and can be an important indicator to a variety of pathologies. Non-invasive methods to quantitatively assess tissue iron with low cost and high sensitivity have drawn vast interests and investments. Among various methods, the magnetoelectric (ME) sensor based biomagnetic liver susceptometer (BLS) is of great promise because it operates at room temperature but with the same principle as that of the well-developed SQUID (Superconducting Quantum Interference Device). Here, we report a magnetoelectric (ME) sensor based BLS system exploiting the recently developed PIN-PMN-PT piezoelectric single crystal. The newly developed ME BLS, which employs the horizontal scanning mechanism with a water bath interface to automatically eliminate the diamagnetic background of the tissues and irregular shape of torso, exhibits an overall sensitivity advancement (300X) to the sensor system previously reported. A linear correlation (R2 = 0.97) found between the system measurements and the biopsy data demonstrates the validity of the system. The ability to detect signals from only 3cc of mouse liver tissue samples suggests a high spatial resolution which could be used for finer scanning and enable magnetic distribution image and profiling.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA