Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(1)2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38203157

RESUMEN

This paper studies extremely large-scale multiple-input multiple-output (XL-MIMO)-empowered integrated sensing and secure communication systems, where both the radar targets and the communication user are located within the near-field region of the transmitter. The radar targets, being untrusted entities, have the potential to intercept the confidential messages intended for the communication user. In this context, we investigate the near-field beam-focusing design, aiming to maximize the achievable secrecy rate for the communication user while satisfying the transmit beampattern gain requirements for the radar targets. We address the corresponding globally optimal non-convex optimization problem by employing a semidefinite relaxation-based two-stage procedure. Additionally, we provide a sub-optimal solution to reduce complexity. Numerical results demonstrate that beam focusing enables the attainment of a positive secrecy rate, even when the radar targets and communication user align along the same angle direction.

2.
Micromachines (Basel) ; 14(11)2023 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-38004863

RESUMEN

With the increasing demand for the miniaturization and flexibility of optical devices, graphene-based metasurfaces have emerged as a promising ideal design platform for realizing planar and tunable electromagnetic or optical devices. In this paper, we propose a tunable metasurface with low-dispersion phase gradient characteristics that is composed of an array of double-layer graphene ribbons sandwiched with a thin insulating layer and a polymer substrate layer with a gold ground plane. As two typical proof-of-concept examples, metasurfaces act as a planar prism and a planar lens, respectively, and the corresponding performances of tunable broadband dispersion are demonstrated through full-wave simulation experiments. By changing the Fermi level of each graphene ribbon individually to introduce abrupt phase shifts along the metasurface, the broadband continuous dispersion effect of abnormal reflection and beam focusing is achieved within a terahertz (THz) frequency region from 3.0 THz to 4.0 THz, and the dispersion results can be freely regulated by reconfiguring the sequence of Fermi levels via the bias voltage. The presented graphene metasurface provides an avenue for the dispersion manipulation of a broadband terahertz wave and may have great prospects in the fields of optics, imaging, and wireless communication.

3.
Sensors (Basel) ; 23(4)2023 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-36850570

RESUMEN

This work presents a high-efficiency reconfigurable wireless-power-transfer (WPT) system using fully rollable Tx/Rx coils and a metasurface (MS) screen working at 6.78 MHz, for the first time. The MS screens are placed between the Tx and Rx to magnify the power-transfer efficiency (PTE) of the WPT system. The proposed MS-based WPT can be rolled down or rolled up as required, which allows end-users to use the space more flexibly. In the measurement results, the PTE of the WPT is improved from 13.32% to 32.49% at a power-transfer distance (PTD) of 40 cm with one MS screen, 5.42% to 42.25% at a PTD of 50 cm with two MS screens, 1.78% to 49% at a PTD of 60 cm with three MS screens, 0.85% to 46.24% at a PTD of 70 cm with four MS screens. The measured PTE results indicate that the demonstrated MS screens are greatly effective for magnifying the PTE and the PTD of the WPT. In addition, the measured PTE results in the misaligned condition verify that the MS screens also help increase the PTE of the WPT even in the misalignment condition.

4.
Phys Rev Appl ; 18(2)2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36600893

RESUMEN

Airy beams are peculiar beams that are non-diffracting, self-accelerating, and self-healing, and they have offered great opportunities for ultrasound beam manipulation. However, one critical barrier that limits the broad applications of Airy beams in ultrasound is the lack of simply built device to generate Airy beams in water. This work presents a family of Airy beam-enabled binary acoustic metasurfaces (AB-BAMs) to generate Airy beams for underwater ultrasound beam manipulation. AB-BAMs are designed and fabricated by 3D printing with two coding bits: a polylactic acid (which is the commonly used 3D printing material) unit acting as a bit "1" and a water unit acting as a bit "0". The distribution of the binary units on the metasurface is determined by the pattern of Airy beam. To showcase the wavefront engineering capability of the AB-BAMs, several examples of AB-BAMs are designed, 3D printed, and coupled with a planar single-element ultrasound transducer for experimental validation. We demonstrate the capability of AB-BAMs in flexibly tuning the focal region size and beam focusing in 3D space by changing the design of the AB-BAMs. The focal depth of AB-BAMs can be continuous and electronical tuned by adjusting the operating frequency of the planar transducer without replacing the AB-BAMs. The superimposing method is leveraged to enable the generation of complex acoustic fields, e.g., multi-foci and letter patterns (e.g., "W" and "U"). The more complex focal patterns are shown to be also continuously steerable by simply adjusting the operating frequency. Furthermore, the proposed 3D-printed AB-BAMs are simple to design, easy to fabricate, and low-cost to produce with the capabilities to achieve tunable focal size, flexible 3D beam focusing, arbitrary multipoint focusing, and continuous steerability, which creates unprecedented potential for ultrasound beam manipulation.

5.
Materials (Basel) ; 13(23)2020 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-33291342

RESUMEN

Nonlinear ultrasound has been proven to be a useful nondestructive testing tool for micro-damage inspection of materials and structures operating in harsh environment. When measuring the nonlinear second harmonic wave in a solid specimen in the pulse-echo (PE) testing mode, the stress-free boundary characteristics brings the received second harmonic component close to zero. Therefore, the PE method has never been employed to measure the so-called "nonlinear parameter (ß)", which is used to quantify the degree of micro-damage. When there are stress-free boundaries, a focused beam is known to improve the PE reception of the second harmonic wave, so phased-array (PA) transducers can be used to generate the focused beam. For the practical application of PE nonlinear ultrasonic testing, however, it is necessary to develop a new type of PA transducer that is completely different from conventional ones. In this paper, we propose a new annular PA transducer capable of measuring ß with improved second harmonic reception in the PE mode. Basically, the annular PA transducer (APAT) consists of four external ring transmitters and an internal disk receiver at the center. The focused beam properties of the transducers are analyzed using a nonlinear sound beam model which incorporates the effects of beam diffraction, material attenuation, and boundary reflection. The optimal design of the APAT is performed in terms of the maximum second harmonic reception and the total correction close to one, and the results are presented in detail.

6.
Molecules ; 23(11)2018 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-30400257

RESUMEN

With the increasing interest in scarce proteins, reducing the sample volume for circular dichroism (CD) spectroscopy has become desirable. Demagnification of the incident beam size is required to reduce the sample volume for CD spectroscopy detecting transmitted light passed through the sample. In this study, the beam size was demagnified using a focal mirror, and small-capacity sample cells were developed in an attempt to reduce the sample volume. The original beam size was 6 × 6 mm²; we successfully converged it to a size of 25 × 25 µm² using the Schwarzschild objective (SO). The new sample cell and SO allowed the required sample volume to be reduced to 1/10 (15 → 1.5 µL), when using a 15 µm path length cell. By adopting a smaller sample cell, further sample reduction could be achieved. By using the SO system, the secondary structural contents of the lysine-36 trimethylated histone H3 protein were analyzed. The trimethylation induced the increment of helix structures and decrement of unordered structures. These structural alterations may play a role in regulating cellular function(s), such as DNA damage repair processes.


Asunto(s)
Dicroismo Circular , Histonas/química , Lisina/química , Estructura Molecular , Estructura Secundaria de Proteína , Reproducibilidad de los Resultados
7.
Micromachines (Basel) ; 9(11)2018 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-30428598

RESUMEN

Although the lab-on-a-chip system has been successfully applied in a wide variety of fields, the goal of achieving a cell counter with simple operation, low cost, and high accuracy still attracts continuous research efforts. In this paper, the authors explore a cell counter based on light beam focusing to measure the density of adherent cells. In this sensor, the light emitted from the optical fibers is collimated by the collimating lens formed in polydimethylsiloxane (PDMS). The uniformly attached adherent cells act as a convex lens, focusing the collimated light propagated through them. The intensity of the focused light indicates the density of the adherent cells. For Hela cells, a detection limit of 8.3 × 104 cells/mL with a detection range from 0.1 × 106 cells/mL to 1.0 × 106 cells/mL is achieved. This sensor is particularly useful for drug screening, cell pathology analysis, and cancer pre-diagnosis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA