Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 187
Filtrar
1.
Circulation ; 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39101201

RESUMEN

BACKGROUND: Systemic arterial compliance and venous capacitance are typically impaired in patients with heart failure with preserved ejection fraction (HFpEF), contributing to hemodynamic congestion with stress. Sodium-glucose cotransporter-2 inhibitors reduce hemodynamic congestion and improve clinical outcomes in patients with HFpEF, but the mechanisms remain unclear. This study tested the hypothesis that Dapagliflozin would improve systemic arterial compliance and venous capacitance during exercise in patients with HFpEF. METHODS: In this secondary analysis from the Cardiac and Metabolic Effects of Dapagliflozin in Heart Failure With Preserved Ejection Fraction Trial, 37 patients with HFpEF (mean age 68 ± 9 years, women 65%) underwent invasive hemodynamic exercise testing with simultaneous echocardiography at baseline and following treatment for 24 weeks with Dapagliflozin or placebo. Radial artery pressure (BP) was measured continuously using a fluid-filled catheter with transformation to aortic pressure, central hemodynamics were measured using high-fidelity micromanometers, and stressed blood volume was estimated from hemodynamic indices fit to a comprehensive cardiovascular model. RESULTS: There was no statistically significant effect of Dapagliflozin on resting BP, but Dapagliflozin reduced systolic BP during peak exercise (estimated treatment difference [ETD], -18.8 mm Hg [95% CI, -33.9 to -3.7] P=0.016). Reduction in BP was related to improved exertional total arterial compliance (ETD, 0.06 mL/mm Hg/m2 [95% CI, 0.003-0.11] P=0.039) and aortic root characteristic impedance (ETD, -2.6 mm Hg/mL*sec [95% CI: -5.1 to -0.03] P=0.048), with no significant effect on systemic vascular resistance. Dapagliflozin reduced estimated stressed blood volume at rest and during peak exercise (ETD, -292 mm Hg [95% CI, -530 to -53] P=0.018), and improved venous capacitance evidenced by a decline in ratio of estimated stressed blood volume to total blood volume (ETD, -7.3% [95% CI, -13.3 to -1.3] P=0.020). Each of these effects of Dapagliflozin at peak exercise were also observed during matched 20W exercise intensity. Improvements in total arterial compliance and estimated stressed blood volume were correlated with decreases in body weight, and reduction in systolic BP with treatment was correlated with the change in estimated stressed blood volume during exercise (r=0.40, P=0.019). Decreases in BP were correlated with reduction in pulmonary capillary wedge pressure during exercise (r=0.56, P<0.001). CONCLUSIONS: In patients with HFpEF, treatment with Dapagliflozin improved systemic arterial compliance and venous capacitance during exercise, while reducing aortic characteristic impedance, suggesting a reduction in arterial wall stiffness. These vascular effects may partially explain the clinical benefits with sodium-glucose cotransporter-2 inhibitors in HFpEF. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04730947.

2.
Int J Cardiol Heart Vasc ; 53: 101472, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39171287

RESUMEN

Pulmonary hypertension (PH) is a common and prognostically important complication of mitral regurgitation (MR). Mean pulmonary arterial pressure (mPAP) and pulmonary vascular resistance (PVR) are traditionally used to diagnose PH, however these indices measure static rather than pulsatile load, leading to an incomplete representation of pulmonary vascular load on the right ventricle (RV). Pulmonary arterial compliance (PAC) is one method for quantifying pulsatile load, and is both a stronger predictor of prognosis in left heart failure, as well as a more sensitive measure of early pulmonary vascular dysfunction than PVR. With the expansion of transcatheter mitral and tricuspid valve therapies, there is renewed interest to more accurately define the load imposed by the pulmonary vasculature on the RV, especially in the early phase, prior to the onset of chronic PH. This review discusses the pathophysiology of pH in left heart failure and MR, the utility of PAC as a measure of RV afterload, and its calculation for clinical use and interpretation, underlining the utility of PAC as an adjunct for assessing pulmonary vascular haemodynamics.

3.
J Transl Med ; 22(1): 670, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39030538

RESUMEN

BACKGROUND: As key regulators of gene expression, microRNAs affect many cardiovascular mechanisms and have been associated with several cardiovascular diseases. In this study, we aimed to investigate the relation of whole blood microRNAs with several quantitative measurements of vascular function, and explore their biological role through an integrative microRNA-gene expression analysis. METHODS: Peripheral whole blood microRNA expression was assessed through RNA-Seq in 2606 participants (45.8% men, mean age: 53.93, age range: 30 to 95 years) from the Rhineland Study, an ongoing population-based cohort study in Bonn, Germany. Weighted gene co-expression network analysis was used to cluster microRNAs with highly correlated expression levels into 14 modules. Through linear regression models, we investigated the association between each module's expression and quantitative markers of vascular health, including pulse wave velocity, total arterial compliance index, cardiac index, stroke index, systemic vascular resistance index, reactive skin hyperemia and white matter hyperintensity burden. For each module associated with at least one trait, one or more hub-microRNAs driving the association were defined. Hub-microRNAs were further characterized through mapping to putative target genes followed by gene ontology pathway analysis. RESULTS: Four modules, represented by hub-microRNAs miR-320 family, miR-378 family, miR-3605-3p, miR-6747-3p, miR-6786-3p, and miR-330-5p, were associated with total arterial compliance index. Importantly, the miR-320 family module was also associated with white matter hyperintensity burden, an effect partially mediated through arterial compliance. Furthermore, hub-microRNA miR-192-5p was related to cardiac index. Functional analysis corroborated the relevance of the identified microRNAs for vascular function by revealing, among others, enrichment for pathways involved in blood vessel morphogenesis and development, angiogenesis, telomere organization and maintenance, and insulin secretion. CONCLUSIONS: We identified several microRNAs robustly associated with cardiovascular function, especially arterial compliance and cardiac output. Moreover, our results highlight miR-320 as a regulator of cerebrovascular damage, partly through modulation of vascular function. As many of these microRNAs were involved in biological processes related to vasculature development and aging, our results contribute to the understanding of vascular physiology and provide putative targets for cardiovascular disease prevention.


Asunto(s)
MicroARNs , Humanos , Masculino , Persona de Mediana Edad , Femenino , MicroARNs/sangre , MicroARNs/genética , Anciano , Adulto , Anciano de 80 o más Años , Redes Reguladoras de Genes , Regulación de la Expresión Génica , Vasos Sanguíneos/fisiología , Estudios de Cohortes , Ontología de Genes , Perfilación de la Expresión Génica
4.
Front Physiol ; 15: 1398904, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38915780

RESUMEN

Arterial compliance (AC) plays a crucial role in vascular aging and cardiovascular disease. The ability to continuously estimate aortic AC or its surrogate, pulse pressure (PP), through wearable devices is highly desirable, given its strong association with daily activities. While the single-site photoplethysmography (PPG)-derived arterial stiffness indices show reasonable correlations with AC, they are susceptible to noise interference, limiting their practical use. To overcome this challenge, our study introduces a noise-resistant indicator of AC: Katz's fractal dimension (KFD) of PPG signals. We showed that KFD integrated the signal complexity arising from compliance changes across a cardiac cycle and vascular structural complexity, thereby decreasing its dependence on individual characteristic points. To assess its capability in measuring AC, we conducted a comprehensive evaluation using both in silico studies with 4374 virtual human data and real-world measurements. In the virtual human studies, KFD demonstrated a strong correlation with AC (r = 0.75), which only experienced a slight decrease to 0.66 at a signal-to-noise ratio of 15dB, surpassing the best PPG-morphology-derived AC measure (r = 0.41) under the same noise condition. In addition, we observed that KFD's sensitivity to AC varied based on the individual's hemodynamic status, which may further enhance the accuracy of AC estimations. These in silico findings were supported by real-world measurements encompassing diverse health conditions. In conclusion, our study suggests that PPG-derived KFD has the potential to continuously and reliably monitor arterial compliance, enabling unobtrusive and wearable assessment of cardiovascular health.

5.
Front Cardiovasc Med ; 11: 1377887, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38689863

RESUMEN

Background: Hypertension is highly prevalent and particularly difficult to treat adequately in patients with chronic kidney disease (CKD). The relative contribution of volume overload and vascular mechanisms to blood pressure measures in CKD and whether these effects differ in non-dialysis compared to dialysis patients is unknown. Methods: We determined the potential impact of volume load (stroke volume) and vascular mechanisms (inverse of total arterial compliance (inv TAC) and systemic vascular resistance (SVR)) on mean and brachial and aortic systolic blood pressures in 67 non-dialysis and 48 dialysis chronic kidney disease (CKD) patients. Relationships were determined in confounder adjusted regression models. Results: Stroke volume (p value = 0.003) was more strongly associated with mean arterial pressure than SVR (p value = 0.9) (p value for difference = 0.03). When stroke volume and SVR were entered in the same regression model (model R2 = 0.324), they contributed equally to the variation in mean arterial pressure (p value for difference = 0.5). Stroke volume (p value ≤ 0.002) and inv TAC (p value ≤ 0.001) contributed equally to the variation in systolic pressures (p value for difference ≥ 0.9). When stroke volume and inv TAC were entered in the same regression model (model R2 = 0.752 to 0.765), they contributed equally to the variation in systolic blood pressures (p value for difference = 0.7). Stroke volume, TAC and SVR were similar (p value ≥ 0.5) and associated to the same extent with blood pressure measures in non-dialysis and dialysis CKD patients (p value for difference ≥ 0.1). In receiver operator characteristic curve analysis, elevated systolic blood pressure was determined by stroke volume (p value = 0.005) and inv TAC (p value = 0.03) but not SVR (p value = 0.8). The calculated power of the study was 0.999 based on α = 0.05. Conclusions: The present investigation suggests that both volume load and vascular mechanisms should be considered in the management of hypertension among patients with CKD. The extent and relative potential impact of volume load and vascular mechanisms on blood pressure measures are as large in non-dialysis compared to dialysis CKD patients.

6.
Front Netw Physiol ; 4: 1346424, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38638612

RESUMEN

The concept of self-predictability plays a key role for the analysis of the self-driven dynamics of physiological processes displaying richness of oscillatory rhythms. While time domain measures of self-predictability, as well as time-varying and local extensions, have already been proposed and largely applied in different contexts, they still lack a clear spectral description, which would be significantly useful for the interpretation of the frequency-specific content of the investigated processes. Herein, we propose a novel approach to characterize the linear self-predictability (LSP) of Gaussian processes in the frequency domain. The LSP spectral functions are related to the peaks of the power spectral density (PSD) of the investigated process, which is represented as the sum of different oscillatory components with specific frequency through the method of spectral decomposition. Remarkably, each of the LSP profiles is linked to a specific oscillation of the process, and it returns frequency-specific measures when integrated along spectral bands of physiological interest, as well as a time domain self-predictability measure with a clear meaning in the field of information theory, corresponding to the well-known information storage, when integrated along the whole frequency axis. The proposed measure is first illustrated in a theoretical simulation, showing that it clearly reflects the degree and frequency-specific location of predictability patterns of the analyzed process in both time and frequency domains. Then, it is applied to beat-to-beat time series of arterial compliance obtained in young healthy subjects. The results evidence that the spectral decomposition strategy applied to both the PSD and the spectral LSP of compliance identifies physiological responses to postural stress of low and high frequency oscillations of the process which cannot be traced in the time domain only, highlighting the importance of computing frequency-specific measures of self-predictability in any oscillatory physiologic process.

7.
Nitric Oxide ; 146: 24-30, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38521488

RESUMEN

BACKGROUND: Cardiopulmonary bypass (CPB) is associated with intravascular hemolysis which depletes endogenous nitric oxide (NO). The impact of hemolysis on pulmonary arterial compliance (PAC) and right ventricular systolic function has not been explored yet. We hypothesized that decreased NO availability is associated with worse PAC and right ventricular systolic function after CPB. METHODS: This is a secondary analysis of an observational cohort study in patients undergoing cardiac surgery with CPB at Massachusetts General Hospital, USA (2014-2015). We assessed PAC (stroke volume/pulmonary artery pulse pressure ratio), and right ventricular function index (RVFI) (systolic pulmonary arterial pressure/cardiac output), as well as NO consumption at 15 min, 4 h and 12 h after CPB. Patients were stratified by CPB duration. Further, we assessed the association between changes in NO consumption with PAC and RVFI between 15min and 4 h after CPB. RESULTS: PAC was lowest at 15min after CPB and improved over time (n = 50). RVFI was highest -worse right ventricular function- at CPB end and gradually decreased. Changes in hemolysis, PAC and RVFI differed over time by CPB duration. PAC inversely correlated with total pulmonary resistance (TPR). TPR and PAC positively and negatively correlated with RVFI, respectively. NO consumption between 15min and 4 h after CPB correlated with changes in PAC (-0.28 ml/mmHg, 95%CI -0.49 to -0.01, p = 0.012) and RVFI (0.14 mmHg*L-1*min, 95%CI 0.10 to 0.18, p < 0.001) after multivariable adjustments. CONCLUSION: PAC and RVFI are worse at CPB end and improve over time. Depletion of endogenous NO may contribute to explain changes in PAC and RVFI after CPB.


Asunto(s)
Puente Cardiopulmonar , Hemólisis , Arteria Pulmonar , Función Ventricular Derecha , Humanos , Masculino , Femenino , Persona de Mediana Edad , Función Ventricular Derecha/fisiología , Anciano , Arteria Pulmonar/fisiología , Arteria Pulmonar/fisiopatología , Óxido Nítrico/metabolismo , Sístole/fisiología , Estudios de Cohortes , Adaptabilidad
8.
Eur J Heart Fail ; 26(3): 686-694, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38481353

RESUMEN

AIMS: A common feature of various forms of pulmonary hypertension (PH) is progressive decline of pulmonary arterial compliance (CPA), which correlates with reduced survival. In this acute study, we evaluated feasibility, safety and haemodynamic performance of the Aria pulmonary endovascular device in patients with PH associated with left heart disease (PH-LHD) and chronic lung disease (PH-CLD). METHODS AND RESULTS: Eight patients with PH-LHD and 10 patients with PH-CLD were included in this study. The device was placed in the main pulmonary artery via the right femoral vein and was connected by a catheter to a gas-filled reservoir outside the body. During systole, gas shifts from the balloon to the reservoir, leading to deflation of the balloon. In diastole, the gas returns from the reservoir to the balloon, leading to balloon inflation and enhancing diastolic blood flow to the distal pulmonary capillary bed. Haemodynamics were assessed at baseline, and again with device off, device on and device off. The primary safety endpoint was the incidence of serious adverse events through 30 days after the procedure. No complications or investigational device-related serious adverse events occurred. Device activation in PH-LHD and PH-CLD patients decreased pulmonary arterial pulse pressure by 5.6 ± 4.2 mmHg (-12%; p = 0.003) and 4.2 ± 2.2 mmHg (-11%; p < 0.001), increased CPA by 0.4 ± 0.2 ml/mmHg (+23%; p = 0.004) and 0.4 ± 0.3 ml/mmHg (+25%; p = 0.001), and increased right ventricular-to-pulmonary vascular (RV-PV) coupling by 0.24 ± 0.18 (+40%; p = 0.012) and 0.11 ± 0.07 (+21%; p = 0.001), respectively. CONCLUSIONS: Temporary implantation of the Aria endovascular device was feasible and safe. Device activation resulted in acute improvement of CPA and RV-PV coupling.


Asunto(s)
Hipertensión Pulmonar , Humanos , Masculino , Femenino , Hipertensión Pulmonar/fisiopatología , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Hemodinámica/fisiología , Estudios de Factibilidad , Arteria Pulmonar/fisiopatología , Procedimientos Endovasculares/métodos , Diseño de Equipo
9.
Quant Imaging Med Surg ; 13(12): 7802-7813, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38106282

RESUMEN

Background: Arterial compliance (AC) and vascular resistance (VR) are crucial for the regulation capacity of the vascular system. However, alterations of these features and hemodynamics due to atherosclerosis in a single intracranial artery territory have not been extensively investigated. Thus this study aimed to examine the AC, VR, and hemodynamic variations due to plaque and infarction in the middle cerebral artery (MCA). Methods: Patients with symptomatic MCA atherosclerosis were recruited. Both sides of the MCA were assessed and then classified according to the following scheme: group 0, without plaque; group 1, with plaque but without infarct; group 2, with plaque and infarct in the supplying territories. Data on AC, VR, blood flow, and pulsatility index (PI) were obtained based on 4D flow magnetic resonance imaging (MRI) and the Windkessel model. Results: A total of 63 patients were recruited. After 17 MCAs were excluded (occlusion, n=6; poor image quality, n=11), datasets on 109 MCAs were finally collected and classified into group 0 (n=39), group 1 (n=40), and group 2 (n=30). From groups 0 to 2, there was a decrease in AC (0.0060±0.0031 vs. 0.0052±0.0029 vs. 0.0026±0.0020 mL/mmHg) and an increase in VR [28.65±16.11 vs. 42.59±27.53 vs. 63.21±40.37 mmHg/(mL/s)]. Compared to group 1, group 2 had significantly decreased AC (0.0052±0.0029 vs. 0.0026±0.0020 mL/mmHg; P=0.003) and increased VR [42.59±27.53 vs. 63.21±40.37 mmHg/(mL/s); P=0.021]. From group 0 to group 2, there was a decrease in blood flow (179.29±73.57 vs. 125.11±59.04 vs. 92.05±48.79 mL/min; P<0.001). The PI varied significantly among the 3 groups (0.86±0.20 vs. 1.12±0.50 vs. 0.79±0.16; P<0.001), with group 1 having the highest PI. Conclusions: With the occurrence of plaque and infarct, AC and blood flow progressively decrease while VR increases. The PI was the highest in the group with plaque and without infarct. Assessments of vascular function and hemodynamics in a single artery territory can clarify comprehensive alterations in the cerebral vascular system (CVS).

10.
Adv Exp Med Biol ; 1438: 51-58, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37845439

RESUMEN

We compared differences in perfusion computed tomography (PCT)-derived arterial and venous cerebral blood flow (CBF) in moderate-to-severe traumatic brain injury (TBI) as an indication of changes in cerebral venous outflow patterns referenced to arterial inflow. Moderate-to-severe TBI patients (women 53; men 74) underwent PCT and were stratified into 3 groups: I (moderate TBI), II (diffuse severe TBI without surgery), and III (diffuse severe TBI after the surgery). Arterial and venous CBF was measured by PCT in both the middle cerebral arteries (CBFmca) and the upper sagittal sinus (CBFuss). In group I, CBFmca on the left and right sides were significantly correlated with each other (p < 0.0001) and with CBFuss (p = 0.048). In group II, CBFmca on the left and right sides were also correlated (p < 0.0000001) but not with CBFuss. Intracranial pressure reactivity (PRx) and CBFuss were correlated (p = 0.00014). In group III, CBFmca on the side of the removed hematoma was not significantly different from the opposite CBFmca (p = 0.680) and was not correlated with CBFuss. Conclusions: The increasing severity of TBI is accompanied by an impairment of the correlation between the arterial and venous CBF in the supratentorial vessels suggesting shifting in arterial and venous CBF in severe TBI associated with increased ICP reflected by PRx.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Masculino , Humanos , Femenino , Lesiones Traumáticas del Encéfalo/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Circulación Cerebrovascular/fisiología , Arteria Cerebral Media/diagnóstico por imagen , Perfusión , Presión Intracraneal/fisiología
11.
Biosensors (Basel) ; 13(8)2023 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-37622843

RESUMEN

This paper presents the feasibility of automated and accurate in vivo measurements of vascular parameters using an ultrasound sensor. The continuous and non-invasive monitoring of certain parameters, such as pulse wave velocity (PWV), blood pressure (BP), arterial compliance (AC), and stiffness index (SI), is crucial for assessing cardiovascular disorders during surgeries and follow-up procedures. Traditional methods, including cuff-based or invasive catheter techniques, serve as the gold standard for measuring BP, which is then manually used to calculate AC and SI through imaging algorithms. In this context, the Continuous and Non-Invasive Vascular Stiffness and Arterial Compliance Screener (CaNVAS) is developed to provide continuous and non-invasive measurements of these parameters using an ultrasound sensor. By driving 5 MHz (ranging from 2.2 to 10 MHz) acoustic waves through the arterial walls, capturing the reflected echoes, and employing pre-processing techniques, the frequency shift is utilized to calculate PWV. It is observed that PWV measured by CaNVAS correlates exponentially with BP values obtained from the sphygmomanometer (BPMR-120), enabling the computation of instantaneous BP values. The proposed device is validated through measurements conducted on 250 subjects under pre- and post-exercise conditions, demonstrating an accuracy of 95% and an average coefficient of variation of 12.5%. This validates the reliability and precision of CaNVAS in assessing vascular parameters.


Asunto(s)
Enfermedades Cardiovasculares , Análisis de la Onda del Pulso , Humanos , Reproducibilidad de los Resultados , Presión Sanguínea , Algoritmos
12.
Am J Cardiol ; 204: 195-199, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37544144

RESUMEN

The primary goal of this study was to test the hypothesis that a hybrid intrinsic frequency-machine learning (IF-ML) approach can accurately evaluate total arterial compliance (TAC) and aortic characteristic impedance (Zao) from a single noninvasive carotid pressure waveform in both women and men with heart failure (HF). TAC and Zao are cardiovascular biomarkers with established clinical significance. TAC is lower and Zao is higher in women than in men, so women are more susceptible to the consequent deleterious effects of them. Although the principles of TAC and Zao are pertinent to a multitude of cardiovascular diseases, including HF, their routine clinical use is limited because of the requirement for simultaneous measurements of flow and pressure waveforms. For this study, the data were obtained from the Framingham Heart Study (n = 6,201, 53% women). The reference values of Zao and TAC were computed from carotid pressure and aortic flow waveforms. IF parameters of carotid pressure waveform were used in ML models. IF models were developed on n = 5,168 of randomly selected data and blindly tested the remaining data (n = 1,033). The final models were evaluated in patients with HF. Correlations between IF-ML and reference values in all HF and HF with preserved ejection fraction for TAC were 0.88 and 0.90, and for Zao were 0.82 and 0.80, respectively. The classification accuracy in all HF and HF with preserved ejection fraction for TAC were 0.9 and 0.93, and for Zao were 0.81 and 0.89, respectively. In conclusion, the IF-ML method provides an accurate estimation of TAC and Zao in all subjects with HF and in the general population.


Asunto(s)
Enfermedades Cardiovasculares , Insuficiencia Cardíaca , Masculino , Humanos , Femenino , Impedancia Eléctrica , Aorta , Estudios Longitudinales
13.
Front Physiol ; 14: 1198152, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37457027

RESUMEN

Purpose: Acute (immediate) or regular (mid- or long-term) stretching increases arterial compliance and reduces arterial stiffness. Stretching is widely known to induce arterial functional factor changes, but it is unclear whether stretching alters arterial structural factors. Ultrasound shear wave elastography can quantify the distribution of tissue elastic properties as an index of arterial structural factors. This study thus aimed to examine the effects of acute cervical stretching on arterial wall tissue elastic properties. Methods: Seventeen healthy young adults participated in two different trials for 15 min in random order on separate days: a resting and sitting trial (CON) and a supervised cervical stretching trial (CS). In CS, subjects performed 10 different stretches. At each site, the stretch was held for 30 s followed by a 10-s relaxation period. In CON, subjects rested on a chair for 15 min. Results: After the experiment, carotid arterial compliance, assessed by combined ultrasound imaging and applanation tonometry, was significantly increased in CS, but not in CON. However, there was no significant change in tissue elasticity properties of the arterial wall in either trial, as assessed by ultrasound shear wave elastography. Conclusion: Acute cervical stretching significantly increased carotid artery compliance in young participants, but did not reduce elastic tissue properties (i.e., arterial structural factors) of the carotid artery wall. These results strongly suggest that changes in structural factors have little relation to stretching-induced acute increases in arterial compliance.

14.
Ann Biomed Eng ; 51(11): 2554-2565, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37410199

RESUMEN

The heterogeneity of progression of abdominal aortic aneurysms (AAAs) is not well understood. This study investigates which geometrical and mechanical factors, determined using time-resolved 3D ultrasound (3D + t US), correlate with increased growth of the aneurysm. The AAA diameter, volume, wall curvature, distensibility, and compliance in the maximal diameter region were determined automatically from 3D + t echograms of 167 patients. Due to limitations in the field-of-view and visibility of aortic pulsation, measurements of the volume, compliance of a 60 mm long region and the distensibility were possible for 78, 67, and 122 patients, respectively. Validation of the geometrical parameters with CT showed high similarity, with a median similarity index of 0.92 and root-mean-square error (RMSE) of diameters of 3.5 mm. Investigation of Spearman correlation between parameters showed that the elasticity of the aneurysms decreases slightly with diameter (p = 0.034) and decreases significantly with mean arterial pressure (p < 0.0001). The growth of a AAA is significantly related to its diameter, volume, compliance, and surface curvature (p < 0.002). Investigation of a linear growth model showed that compliance is the best predictor for upcoming AAA growth (RMSE 1.70 mm/year). To conclude, mechanical and geometrical parameters of the maximally dilated region of AAAs can automatically and accurately be determined from 3D + t echograms. With this, a prediction can be made about the upcoming AAA growth. This is a step towards more patient-specific characterization of AAAs, leading to better predictability of the progression of the disease and, eventually, improved clinical decision making about the treatment of AAAs.


Asunto(s)
Aneurisma de la Aorta Abdominal , Humanos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Ultrasonografía , Aorta Abdominal/diagnóstico por imagen , Elasticidad
15.
Front Cardiovasc Med ; 10: 1197842, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37424904

RESUMEN

Background: Arterial stiffening and peripheral wave reflections have been considered the major determinants of raised pulse pressure (PP) and isolated systolic hypertension, but the importance of cardiac contractility and ventricular ejection dynamics is also recognised. Methods: We examined the contributions of arterial compliance and ventricular contractility to variations in aortic flow and increased central (cPP) and peripheral (pPP) pulse pressure, and PP amplification (PPa) in normotensive subjects during pharmacological modulation of physiology, in hypertensive subjects, and in silico using a cardiovascular model accounting for ventricular-aortic coupling. Reflections at the aortic root and from downstream vessels were quantified using emission and reflection coefficients, respectively. Results: cPP was strongly associated with contractility and compliance, whereas pPP and PPa were strongly associated with contractility. Increased contractility by inotropic stimulation increased peak aortic flow (323.9 ± 52.8 vs. 389.1 ± 65.1 ml/s), and the rate of increase (3193.6 ± 793.0 vs. 4848.3 ± 450.4 ml/s2) in aortic flow, leading to larger cPP (36.1 ± 8.8 vs. 59.0 ± 10.8 mmHg), pPP (56.9 ± 13.1 vs. 93.0 ± 17.0 mmHg) and PPa (20.8 ± 4.8 vs. 34.0 ± 7.3 mmHg). Increased compliance by vasodilation decreased cPP (62.2 ± 20.2 vs. 45.2 ± 17.8 mmHg) without altering dP/dt, pPP or PPa. The emission coefficient changed with increasing cPP, but the reflection coefficient did not. These results agreed with in silico data obtained by independently changing contractility/compliance over the range observed in vivo. Conclusions: Ventricular contractility plays a key role in raising and amplifying PP, by altering aortic flow wave morphology.

16.
Actual. anestesiol. reanim ; 70(4): 209-217, Abr. 2023. ilus, tab, graf
Artículo en Español | IBECS | ID: ibc-218272

RESUMEN

Antecedentes y objetivo: El propósito del presente estudio fue evaluar si una red neuronal superficial (RN-S) puede detectar y clasificar los cambios en la presión arterial (PA), dependientes del tono vascular mediante un análisis del contorno de la onda de fotopletismografía (FPG). Material y métodos: Las señales de FPG y PA invasivas fueron simultáneamente registradas en 26 pacientes programados para cirugía general. Se estudió la aparición de episodios de hipertensión (presión arterial sistólica (PAS) > 140 mmHg), normotensión e hipotensión (PAS < 90 mmHg). El tono vascular fue clasificado según la FPG en dos formas: 1) Mediante inspección visual de los cambios en la amplitud de la onda de FPG y en la posición de la incisura dícrota; donde las clases I-II representan vasoconstricción (incisura dícrota ubicada a > 50% de la amplitud de FPG en ondas de pequeña amplitud), tono vascular normal de clase III (incisura dícrota ubicada entre 20-50% de la amplitud de FPG en ondas normales) y vasodilatación de clases IV-V-VI (incisura dícrota a < 20% de la amplitud FPG en ondas grandes). 2) Mediante un análisis automatizado basado en RN-S que combina siete parámetros derivados de la onda de FPG. Resultados: La evaluación visual fue precisa en la detección de hipotensión (sensibilidad 91%, especificidad 86% y precisión 88%) e hipertensión (sensibilidad 93%, especificidad 88% y precisión 90%). La normotensión se presentó como clase visual III (III-III) (mediana y 1°- 3° cuartiles), hipotensión como clase V (IV-VI) e hipertensión como clase II (I-III); todos con significancia estadística (p < 0,0001). La RN-S funcionó bien en la clasificación de las condiciones de PA. El porcentaje de datos con clasificación correcta por la RN-S fue del 83% para normotensión, 94% para hipotensión y 90% para hipertensión. Conclusiones: Los cambios en la PA inducidos por alteraciones en el tono vascular fueron clasificados correctamente de forma automática con una RN-S con base en...(AU)


Background: To test whether a Shallow Neural Network (S-NN) can detect and classify vascular tone dependent changes in arterial blood pressure (ABP) by advanced photopletysmographic (PPG) waveform analysis. Methods: PPG and invasive ABP signals were recorded in 26 patients undergoing scheduled general surgery. We studied the occurrence of episodes of hypertension (systolic arterial pressure (SAP) > 140 mmHg), normotension and hypotension (SAP < 90 mmHg). Vascular tone according to PPG was classified in two ways: 1) By visual inspection of changes in PPG waveform amplitude and dichrotic notch position; where Classes I-II represent vasoconstriction (notch placed > 50% of PPG amplitude in small amplitude waves), Class III normal vascular tone (notch placed between 20-50% of PPG amplitude in normal waves) and Classes IV-V-VI vasodilation (notch < 20% of PPG amplitude in large waves). 2) By an automated analysis, using S-NN trained and validated system that combines seven PPG derived parameters. Results: The visual assessment was precise in detecting hypotension (sensitivity 91%, specificity 86% and accuracy 88%) and hypertension (sensitivity 93%, specificity 88% and accuracy 90%). Normotension presented as a visual Class III (III-III) (median and 1st-3rd quartiles), hypotension as a Class V (IV-VI) and hypertension as a Class II (I-III); all p < 0.0001. The automated S-NN performed well in classifying ABP conditions. The percentage of data with correct classification by S-ANN was 83% for normotension, 94% for hypotension, and 90% for hypertension. Conclusions: Changes in ABP were correctly classified automatically by S-NN analysis of the PPG waveform contour.(AU)


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Anciano , Fotopletismografía , Presión Arterial , Hipotensión , Anestesia General/efectos adversos
17.
Bioengineering (Basel) ; 10(4)2023 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-37106613

RESUMEN

The transaortic valvular pressure gradient (TPG) plays a central role in decision-making for patients suffering from severe aortic stenosis. However, the flow-dependence nature of the TPG makes the diagnosis of aortic stenosis challenging since the markers of cardiac performance and afterload present high physiological interdependence and thus, isolated effects cannot be measured directly in vivo. We used a validated 1D mathematical model of the cardiovascular system, coupled with a model of aortic stenosis, to assess and quantify the independent effect of the main left ventricular performance parameters (end-systolic (Ees) and end-diastolic (Eed) elastance) and principal afterload indices (total vascular resistance (TVR) and total arterial compliance (TAC)) on the TPG for different levels of aortic stenosis. In patients with critical aortic stenosis (aortic valve area (AVA) ≤ 0.6 cm2), a 10% increase of Eed from the baseline value was associated with the most important effect on the TPG (-5.6 ± 0.5 mmHg, p < 0.001), followed by a similar increase of Ees (3.4 ± 0.1 mmHg, p < 0.001), in TAC (1.3 ±0.2 mmHg, p < 0.001) and TVR (-0.7 ± 0.04 mmHg, p < 0.001). The interdependence of the TPG left ventricular performance and afterload indices become stronger with increased aortic stenosis severity. Disregarding their effects may lead to an underestimation of stenosis severity and a potential delay in therapeutic intervention. Therefore, a comprehensive evaluation of left ventricular function and afterload should be performed, especially in cases of diagnostic challenge, since it may offer the pathophysiological mechanism that explains the mismatch between aortic severity and the TPG.

18.
Rev Esp Anestesiol Reanim (Engl Ed) ; 70(4): 209-217, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36868265

RESUMEN

BACKGROUND: To test whether a Shallow Neural Network (S-NN) can detect and classify vascular tone dependent changes in arterial blood pressure (ABP) by advanced photopletysmographic (PPG) waveform analysis. METHODS: PPG and invasive ABP signals were recorded in 26 patients undergoing scheduled general surgery. We studied the occurrence of episodes of hypertension (systolic arterial pressure (SAP) >140 mmHg), normotension and hypotension (SAP < 90 mmHg). Vascular tone according to PPG was classified in two ways: 1) By visual inspection of changes in PPG waveform amplitude and dichrotic notch position; where Classes I-II represent vasoconstriction (notch placed >50% of PPG amplitude in small amplitude waves), Class III normal vascular tone (notch placed between 20-50% of PPG amplitude in normal waves) and Classes IV-V-VI vasodilation (notch <20% of PPG amplitude in large waves). 2) By an automated analysis, using S-NN trained and validated system that combines seven PPG derived parameters. RESULTS: The visual assessment was precise in detecting hypotension (sensitivity 91%, specificity 86% and accuracy 88%) and hypertension (sensitivity 93%, specificity 88% and accuracy 90%). Normotension presented as a visual Class III (III-III) (median and 1st-3rd quartiles), hypotension as a Class V (IV-VI) and hypertension as a Class II (I-III); all p < .0001. The automated S-NN performed well in classifying ABP conditions. The percentage of data with correct classification by S-ANN was 83% for normotension, 94% for hypotension, and 90% for hypertension. CONCLUSIONS: Changes in ABP were correctly classified automatically by S-NN analysis of the PPG waveform contour.


Asunto(s)
Hipertensión , Hipotensión , Humanos , Presión Arterial , Fotopletismografía , Hipertensión/diagnóstico , Hipotensión/diagnóstico , Redes Neurales de la Computación
20.
Cardiol Young ; 33(10): 1889-1895, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36325920

RESUMEN

INTRODUCTION: Pulmonary arterial compliance, the dynamic component of pulmonary vasculature, remains inadequately studied in patients with left to right shunts. We sought to study the pulmonary arterial compliance in patients with left to right shunt lesions and its utility in clinical decision-making. MATERIALS AND METHODS: In this single-centre retrospective study, we reviewed cardiac catheterisation data of consecutive patients of left to right shunt lesions catheterised over one year. In addition to the various other parameters, pulmonary arterial compliance was calculated, as indexed pulmonary flow (Qpi) / (Heart rate × pulse pressure in the pulmonary artery). RC time was also calculated, as the product of pulmonary arterial compliance and pulmonary vascular resistance index. Patients were divided into "operable," "borderline," and "inoperable" based on the decision of the treating team, and the pulmonary arterial compliance values were evaluated in these groups to study if it can be utilised to refine the operability decision. RESULTS: 298 patients (Median age 16 years, 56% <18 years) with various acyanotic shunt lesions were included. Overall, the pulmonary arterial compliance varied with Qpi, pulmonary artery mean pressure, and pulmonary vascular resistance index, but did not vary with age, type of lesion, or transpulmonary gradients. The median pulmonary arterial compliance in patients with normal pulmonary artery pressure (Mean pulmonary artery pressure less than 20 mmHg) was 4.1 ml/mmHg/m2 (IQR 3.2). The median pulmonary arterial compliance for operable patients was 2.67 ml/mmHg/m2 (IQR 2.2). Median pulmonary arterial compliance was significantly lower in both inoperable (0.52 ml/mmHg/m2, IQR 0.34) and borderline (0.80 ml/mmHg/m2, IQR 0.36) groups when compared to operable patients (p < 0.001). A pulmonary arterial compliance value lower than 1.18 ml/mmHg/m2 identified inoperable patients with high sensitivity and specificity (95%, AUC 0.99). However, in borderline cases, assessment by this value did not agree with empirical clinical assessment.The median RC time for the entire study population was 0.47 S (IQR 0.30). RC time in operable patients was significantly lower than that in the inoperable patients (Median 0.40 IQR 0.23 in operable, 0.73 0.25 in inoperable patients (p < 0.001). CONCLUSIONS: Addition of pulmonary arterial compliance to the routine haemodynamic assessment of patients with shunt lesions may improve our understanding of the pulmonary circulation and may have clinical utility.


Asunto(s)
Hipertensión Pulmonar , Arteria Pulmonar , Humanos , Adolescente , Circulación Pulmonar , Estudios Retrospectivos , Resistencia Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA