Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(3)2023 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-36772131

RESUMEN

Here, we report an ultracompact angular displacement sensor based on the Talbot effect of optical microgratings. Periodic Talbot interference patterns were obtained behind an upper optical grating. By putting another grating within the Talbot region, the total transmission of the two-grating structure was found to be approximatively in a linear relationship with the relative pitch angle between the two gratings, which was explained by a transversal shift of the Talbot interference patterns. The influence of the grating parameters (e.g., the grating period, the number of grating lines and the gap between the two gratings) was also studied in both a simulation and an experiment, showing a tunable sensitivity and range by simply changing the grating parameters. A sensitivity of 0.19 mV/arcsec was experimentally obtained, leading to a relative sensitivity of 0.27%/arcsec within a linear range of ±396 arcsec with the 2 µm-period optical gratings. Benefitting from tunable properties and an ultracompact structure, we believe that the proposed sensor shows great potential in applications such as aviation, navigation, robotics and manufacturing engineering.

2.
Biomed Tech (Berl) ; 68(2): 211-223, 2023 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-36563350

RESUMEN

Blood coagulation function is an essential index in clinical examination, and it is of great significance to evaluate blood coagulation function comprehensively. Based on the blood viscoelasticity theory and hydrodynamics, we proposed a method to monitor the whole blood coagulation process based on the reciprocating motion of the magnetic bead (magnetic bead method for short). We have established a mathematical model between the moment acting on the magnetic bead and the viscoelasticity of blood in the process of blood coagulation. The change of blood viscoelasticity acks on the magnetic bead in the form of moment changes, which shows that the amplitude of the motion of the magnetic bead varies with the change of blood viscoelasticity. Designed and verified a blood coagulation monitoring device based on the reciprocating movement of the magnetic bead and discussed the device's parameters through the orthogonal experiment. Lastly, the TEG5000 was used as the control group to test the thromboelasticity of four groups of thromboelastography quality control products in the same batch and 10 groups of human whole blood. It verified that our device has good repeatability, and has good consistency with TEG5000, it has particular application potential as a new blood coagulation monitoring method.


Asunto(s)
Coagulación Sanguínea , Tromboelastografía , Humanos , Tromboelastografía/métodos , Viscosidad , Movimiento , Fenómenos Magnéticos
3.
Sensors (Basel) ; 21(9)2021 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-33946761

RESUMEN

To fulfill the requirement of fields such as robotics, aviation, and special machining, motors with quill shafts or outer rotors have been used. For these special motors, the photoelectric encoder's volume is normally too big and easy to be polluted by oil or dust; magnetic encoder normally has poor accuracy, and alnico piece may not provide enough magnetic field coverage area. The aim of this essay is to find a new structure of magnetic encoder to improve the precision and magnetic field coverage area. By using two multi-pole alnico rings with a different number of pole pairs to provide a magnetic field, the coverage area could be improved. The position differences between two alnicos pole positions are used to calculate absolute angle value, so the accuracy of the encoder could be absolute and no less than that of a combined magnetic encoder with the same number of pole pairs. A special algorithm is proposed for decoding. This new kind of magnetic encoder could be used on special motors with quill shafts or outer rotors. Its volume and weight are less than the photoelectric encoder and have better performance on antipollution. The alnico ring is easy to modify to suit the structure of the motor.

4.
Sensors (Basel) ; 19(9)2019 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-31086064

RESUMEN

Angular displacement sensor with shared magnetic field has strong environmental adaptability and high measurement accuracy. However, its 3-D structure is multi-pole double-layer structure, using time stepping finite element method (TSFEM) to optimize the structure is time-consuming and uneconomical. Therefore, a magnetic equivalent loop method (MELM) is proposed to simplify the optimal design of sensors. By reasonably setting the node position, the mechanical structure parameters, winding coefficients and input voltage of the sensor are integrated into a mathematical model to calculate of the induced voltage. The calculation results are compared with the simulation results, and a sensor prototype is made to test the optimized effect of the MELM.

5.
Sensors (Basel) ; 16(9)2016 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-27649199

RESUMEN

In this paper, a novel differential reflective intensity optical fiber angular displacement sensor was proposed. This sensor can directly measure the angular and axial linear displacement of a flat surface. The structure of the sensor probe is simple and its basic principle was first analyzed according to the intensity modulation mechanisms. Secondly, in order to trim the dark output voltage to zero, the photoelectric conversion circuit was developed to adjust the signals. Then, the sensor model including the photoelectric conversion circuit has been established, and the influence of design parameters on the sensor output characteristic has been simulated. Finally, the design parameters of the sensor structure were obtained based on the simulation results; and an experimental test system was built for the sensor calibration. Experimental results show that the linear angular range and the sensitivity of the sensor were 74.4 and 0.051 V/°, respectively. Its change rules confirm the operating principle of the sensor well.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA