Resultados 1 - 20 de 279
Filtrar
1.
Clin Chem Lab Med ; 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39238208

RESUMEN

OBJECTIVES: This study aimed to assess the validity of external quality assessment (EQA) laboratory results across various cultural and environmental contexts and to identify potential improvement areas. METHODS: The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Global Laboratory Quality (TF-GLQ) conducted a 2-year study (2022 and 2023) in which EQA materials, related software and online training was provided by a commercial vendor to 100 laboratories in ten IFCC member society countries. The results were analysed on a monthly basis by the TF-GLQ, to show the number of submissions per country, tests per lab, acceptability rates, random failures and to get a measure of which analytes performed poorly. RESULTS: The EQA material was dispatched on a quarterly basis. Some countries had problems with customs releasing the material in a timely manner, resulting in laboratories not receiving them on time leading to no submission. We report here the results for the second year of the survey. The number of examinations varied between laboratories, ranging from seven to 84 analytes. Of the ten countries surveyed, six averaged greater than 90 % acceptable results over the whole 12-months cycle, one had unacceptable results for two of the nine months they returned results and the other four were considered to not perform to an acceptable standard. CONCLUSIONS: All 100 participating laboratories indicated satisfaction with the EQA survey and related services, including on-site training, and report handling. However, specimen receiving issues, suggest benefits in dispatching materials for a full 12-month cycle. Significant discrepancies in EQA performance indicate that four countries require long-term assistance, training and guidance. To ensure reliable patient results, promoting EQA in certain countries is essential to achieve the required level of quality.

2.
Mikrochim Acta ; 191(9): 535, 2024 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-39141139

RESUMEN

Photoelectrochemical (PEC) nanobiosensors integrate molecular (bio)recognition elements with semiconductor/plasmonic photoactive nanomaterials to produce measurable signals after light-induced reactions. Recent advancements in PEC nanobiosensors, using light-matter interactions, have significantly improved sensitivity, specificity, and signal-to-noise ratio in detecting (bio)analytes. Tunable nanomaterials activated by a wide spectral radiation window coupled to electrochemical transduction platforms have further improved detection by stabilizing and amplifying electrical signals. This work reviews PEC biosensors based on nanomaterials like metal oxides, carbon nitrides, quantum dots, and transition metal chalcogenides (TMCs), showing their superior optoelectronic properties and analytical performance for the detection of clinically relevant biomarkers. Furthermore, it highlights the innovative role of red light and NIR-activated PEC nanobiosensors in enhancing charge transfer processes, protecting them from biomolecule photodamage in vitro and in vivo applications. Overall, advances in PEC detection systems have the potential to revolutionize rapid and accurate measurements in clinical diagnostic applications. Their integration into miniaturized devices also supports the development of portable, easy-to-use diagnostic tools, facilitating point-of-care (POC) testing solutions and real-time monitoring.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Rayos Infrarrojos , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Humanos , Nanoestructuras/química , Puntos Cuánticos/química , Puntos Cuánticos/efectos de la radiación , Animales , Procesos Fotoquímicos , Biomarcadores/análisis
3.
ACS Sens ; 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39166946

RESUMEN

Continuous biosensors measure concentration-time profiles of biomolecular substances in order to allow for comparisons of measurement data over long periods of time. To make meaningful comparisons of time-dependent data, it is essential to understand how measurement imprecision depends on the time interval between two evaluation points, as the applicable imprecision determines the significance of measured concentration differences. Here, we define a set of measurement imprecisions that relate to different sources of variation and different time scales, ranging from minutes to weeks, and study these using statistical analyses of measurement data. The methodology is exemplified for Biosensing by Particle Motion (BPM), a continuous, affinity-based sensing technology with single-particle and single-molecule resolution. The studied BPM sensor measures specific small molecules (glycoalkaloids) in an industrial food matrix (potato fruit juice). Measurements were performed over several months at two different locations, on nearly 50 sensor cartridges with in total more than 1000 fluid injections. Statistical analyses of the measured signals and concentrations show that the relative residuals are normally distributed, allowing extraction and comparisons of the proposed imprecision parameters. The results indicate that sensor noise is the most important source of variation followed by sample pretreatment. Variations caused by fluidic transport, changes of the sensor during use (drift), and variations due to different sensor cartridges and cartridge replacements appear to be small. The imprecision due to sensor noise is recorded over few-minute time scales and is attributed to stochastic fluctuations of the single-molecule measurement principle, false-positive signals in the signal processing, and nonspecific interactions. The developed methodology elucidates both time-dependent and time-independent factors in the measurement imprecision, providing essential knowledge for interpreting concentration-time profiles as well as for further development of continuous biosensing technologies.

4.
Anal Chim Acta ; 1319: 342970, 2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39122280

RESUMEN

BACKGROUND: Across numerous investigations delved into second- and higher-order data, an undoubted finding emerges: models based on such data can effectively exploit the second-order advantage. However, whether further benefits can be achieved by modeling data of higher dimensions remains a subject of inquiry. In this regard, a prevailing question emerges in third-order data-based applications regarding the fundamental need to increase the data dimension and, hence, the data analysis complexity. This study aims to provide meaningful evidence to support the advantages inherent in employing third-order calibration methods despite the associated efforts, such as instrumentation and data analysis complexity. RESULTS: This study compares the analytical performance achieved using a third-order calibration method with those obtained from most of the possible second-order calibration approaches derived from the same dataset. This work delves into the structural properties of the data, modeling limitations, and analytical characteristics associated with each model. Additionally, it includes a comprehensive statistical comparison of the models based on their recovery performance. First, the outcomes demonstrate the importance of capitalizing on all available chemical information and harnessing the full potential of data to maximize its benefits. Moreover, the results provide evidence that asserts the fact that third-order calibration methods bring the opportunity to increase the number of analytes that can be simultaneously determined, notwithstanding the need for more tedious experimental protocols, specialized instrumentation (sometimes), and quite complex data analysis. SIGNIFICANCE: this research marks the first extensive comparison of third-order data calibration models with possible second-order calibration methods. Moreover, this work pioneers the incorporation of highly challenging non-multilinear data. The advancements detailed in this study emphasize the advantages of third-order data acquisition, notwithstanding the need for more tedious experimental protocols, specialized instrumentation (sometimes), and quite complex data analysis.

5.
Pract Lab Med ; 41: e00419, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39205827

RESUMEN

Background: AMH is important in child growth and the concentrations change with age and gender. This study aimed to evaluate the performance of the Pylon AMH assays and establish pediatric reference intervals. Methods: The experiments on imprecision, sensitivity, linearity, reportable range, interference and comparison were carried out to evaluate the analytical performance. The AMH reference ranges were calculated in 238 females and 346 males aged 0-18 years using robust methods. Results: The repeatability and the within-laboratory imprecision CVs of the assay were 3.7 % and 6.4 % at 2.25 ng/mL, and 4.6 % and 6.4 % at 15.49 ng/mL, respectively. The sensitivity (LoB = 0.05 ng/mL, LoD = 0.1 ng/mL and LoQ = 0.3 ng/mL) was verified. The linearity was 0.1-19.55 ng/mL and report up to 391 ng/mL with 20x pre-dilution. There was no significant interference from hemoglobin (500 mg/dL), triglyceride (500 mg/dL), bilirubin (10 mg/dL), cholesterol (800 mg/dL) and biotin (3000 ng/mL). The AMH measured by the Pylon assays correlated to those measured by the Elecsys assays. In males, the AMH levels were high at birth (0 d-1 m: median 95.10 ng/mL) and increased to a peak (7 m-1y: median 158.80 ng/mL) before they decreased with age (15-18 y: median 6.31 ng/mL). In females, the AMH concentrations were low at birth (0 d-1 m: median 0.20 ng/mL) and increased with age (15-18 y: median 3.03 ng/mL). Conclusion: The Pylon AMH assays showed good analytical performance and the AMH reference intervals in chinese children determined may provide a basis in clinical diagnosis and treatment of related diseases.

6.
Clin Chem Lab Med ; 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38987271

RESUMEN

OBJECTIVES: An insulin resistant state is characteristic of patients with type 2 diabetes, polycystic ovary syndrome, and metabolic syndrome. Identification of insulin resistance (IR) is most readily achievable using formulae combining plasma insulin and glucose results. In this study, we have used data from the European Biological Variation Study (EuBIVAS) to examine the biological variability (BV) of IR using the Homeostasis Model Assessment for Insulin Resistance (HOMA-IR) and the Quantitative Insulin sensitivity Check Index (QUICKI). METHODS: Ninety EuBIVAS non-diabetic subjects (52F, 38M) from five countries had fasting HOMA-IR and QUICKI calculated from plasma glucose and insulin samples collected concurrently on 10 weekly occasions. The within-subject (CVI) and between-subject (CVG) BV estimates with 95 % CIs were obtained by CV-ANOVA after analysis of trends, variance homogeneity and outlier removal. RESULTS: The CVI of HOMA-IR was 26.7 % (95 % CI 25.5-28.3), driven largely by variability in plasma insulin and the CVI for QUICKI was 4.1 % (95 % CI 3.9-4.3), reflecting this formula's logarithmic transformation of glucose and insulin values. No differences in values or BV components were observed between subgroups of men or women below and above 50 years. CONCLUSIONS: The EuBIVAS, by utilising a rigorous experimental protocol, has produced robust BV estimates for two of the most commonly used markers of insulin resistance in non-diabetic subjects. This has shown that HOMA-IR, in particular, is highly variable in the same individual which limits the value of single measurements.

7.
Clin Chem Lab Med ; 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39027966

RESUMEN

OBJECTIVES: This article defines analytical performance specifications (APS) for evaluating laboratory proficiency through an external quality assessment scheme. METHODS: Standard deviations for proficiency assessment were derived from Thompson's characteristic function applied to robust data calculated from participants' submissions in the Occupational and Environmental Laboratory Medicine (OELM) external quality assurance scheme for trace elements in serum, whole blood and urine. Characteristic function was based on two parameters: (1) ß - the average coefficient of variation (CV) at high sample concentrations; (2) α - the average standard deviation (SD) at low sample concentrations. APSs were defined as 1.65 standard deviations calculated by Thompson's approach. Comparison between OELM robust data and characteristic function were used to validate the model. RESULTS: Application of the characteristic function allowed calculated APS for 18 elements across three matrices. Some limitations were noted, particularly for elements (1) with no sample concentrations near analytical technique limit of detection; (2) exhibiting high robust CV at high concentration; (3) exhibiting high analytical variability such as whole blood Tl and urine Pb; (4) with an unbalanced number of robust SD above and under the characteristic function such as whole blood Mn and serum Al and Zn. CONCLUSIONS: The characteristic function was a useful means of deriving APS for trace elements in biological fluids where biological variation data or outcome studies were not available. However, OELM external quality assurance scheme data suggests that the characteristic functions are not appropriate for all elements.

8.
Eur J Clin Microbiol Infect Dis ; 43(8): 1597-1607, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38833104

RESUMEN

PURPOSE: To comprehensively investigate the diagnostic performance of routinely used assays in MPXV testing, the National Center of Clinical Laboratories in China conducted a nationwide external quality assessment (EQA) scheme and an evaluated nine assays used by ≥ 5 laboratories in the EQA. METHODS: MPXV virus-like particles with 2700, 900 and 300 copies/mL were distributed to 195 EQA laboratories. For extended analysis, triple-diluted samples from 9000 to 4.12 copies/mL were repeated 20 times using the assays employed by ≥ 5 laboratories. The diagnostic performance was assessed by analyzing EQA data and calculating the limits of detection (LODs). RESULTS: The performance was competent in 87.69% (171/195) of the participants and 87.94% (175/199) of the datasets. The positive percentage agreements (PPAs) were greater than 99% for samples at 2700 and 900 copies/mL, and 95.60% (761/796) for samples at 300 copies/mL. The calculated LODs for the two clades ranged from 228.44 to 924.31 copies/mL and were greater than the LODs specified by the respective kits. EasyDiagnosis had the lowest calculated LODs and showed superior performance in EQA, whereas BioGerm and Sansure, with higher calculated LODs, did not perform well in EQA. CONCLUSION: This study provides valuable information from the EQA data and evaluation of the diagnostic performance of MPXV detection assays. It also provided insights into reagent optimization and enabled prompt public health interventions for the outbreak.


Asunto(s)
Reacción en Cadena en Tiempo Real de la Polimerasa , Sensibilidad y Especificidad , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , China/epidemiología , Límite de Detección , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Monkeypox virus/genética , Monkeypox virus/aislamiento & purificación
9.
Pract Lab Med ; 40: e00414, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38939102

RESUMEN

Background: Most glycated hemoglobin A1c (HbA1c) analytical reagents used were obtained from the analyzer's manufacturer. However, clinical laboratories need more choices for HbA1c analytical reagents to overcome the limitations of dedicated reagents for special analyzers. We developed new mobile phase buffers as HbA1c diagnostic reagents and evaluated their analytical performance for the HbA1c assay. Methods: Different mobile phase buffers used as HbA1c diagnostic reagents were prepared using different concentrations of sodium salts. According to the Clinical and Laboratory Standards Institute (CLSI) recommendation guidelines, the analytical performances of the newly developed mobile phase buffers were evaluated on an ARKRAY HA-8160 Analyzer. Both quality controls and clinical blood samples were used in these experiments. To assess the quality of the newly developed mobile phase buffers, precision, accuracy, linearity, carryover, interference, bias, correlation with commercial reagents, and stability were analyzed. Results: The CVs of intra-assay precision and interassay precision of quality control and clinical.There were fewer than 1.00 % blood sample assays using the newly developed mobile phase buffer. The RDs of accuracy were less than 1.00 %. Linearity: R2 = 0.9998 in the concentration range of 4.40%-17.30 %. Carryover: 0.00 %. Reagent comparison revealed that the Pearson regression equation was Y = 0.9884x+0.05692 (R2 = 0.9977), and the Bland-Altman mean difference was -0.02650 % (CI: -0.2121 %-0.1591 %) between the two analytical reagents. Stability was also acceptable within 12 months. This mobile phase buffer showed good anti-interference ability. Conclusion: The newly developed mobile phase buffers demonstrated good analytical performance and were suitable for clinical HbA1c assays on an ARKRAY HA-8160 Analyzer.

10.
Clin Chem Lab Med ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38874995

RESUMEN

OBJECTIVES: Glycated albumin (GA) has potential value in the management of people with diabetes; however, to draw meaningful conclusions between clinical studies it is important that the GA values are comparable. This study investigates the standardization of the Norudia Glycated Albumin and Lucica Glycated Albumin-L methods. METHODS: The manufacturer reported imprecision was verified by performing CLSI-EP15-A3 protocol using manufacturer produced controls. The Japanese Clinical Chemistry Reference Material (JCCRM)611-1 was measured 20 times to evaluate the accuracy of both methods. GA was also measured in 1,167 patient samples and results were compared between the methods in mmol/mol and %. RESULTS: Maximum CV for Lucica was ≤0.6 % and for Norudia ≤1.8 % for control material. Results in mmol/mol and % of the JCCRM611-1 were within the uncertainty of the assigned values for both methods. In patient samples the relative difference in mmol/mol between the two methods ranged from -10.4 % at a GA value of 183 mmol/mol to +8.7 % at a GA value of 538 mmol/mol. However, the relative difference expressed in percentage units ranged from of 0 % at a GA value of 9.9 % to +1.7 % at a GA value of 30 %. CONCLUSIONS: The results in mmol/mol between the two methods for the patient samples were significantly different compared to the results in %. It is not clear why patient samples behave differently compared to JCCRM611-1 material. Valuable lessons can be learnt from comparing the standardization process of GA with that of HbA1c.

12.
Clin Chem Lab Med ; 62(8): 1474-1482, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-38836433

RESUMEN

Analytical performance specifications (APS) based on outcomes refer to how 'good' the analytical performance of a test needs to be to do more good than harm to the patient. Analytical performance of a measurand affects its clinical performance. Without first setting clinical performance requirements, it is difficult to define how good analytically the test needs to be to meet medical needs. As testing is indirectly linked to health outcomes through clinical decisions on patient management, often simulation-based studies are used to assess the impact of analytical performance on the probability of clinical outcomes which is then translated to Model 1b APS according to the Milan consensus. This paper discusses the related key definitions, concepts and considerations that should assist in finding the most appropriate methods for deriving Model 1b APS. We review the advantages and limitations of published methods and discuss the criteria for transferability of Model 1b APS to different settings. We consider that the definition of the clinically acceptable misclassification rate is central to Model 1b APS. We provide some examples and guidance on a more systematic approach for first defining the clinical performance requirements for tests and we also highlight a few ideas to tackle the future challenges associated with providing outcome-based APS for laboratory testing.


Asunto(s)
Técnicas de Laboratorio Clínico , Humanos , Técnicas de Laboratorio Clínico/normas
14.
Diagnostics (Basel) ; 14(11)2024 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-38893633

RESUMEN

In April 2020, the Aboriginal and Torres Strait Islander COVID-19 Point-of-Care (POC) Testing Program was initiated to improve access to rapid molecular-based SARS-CoV-2 detection in First Nations communities. At capacity, the program reached 105 health services across Australia. An external review estimated the program contributed to averting between 23,000 and 122,000 COVID-19 infections within 40 days of the first infection in a remote community, equating to cost savings of between AU$337 million and AU$1.8 billion. Essential to the quality management of this program, a customised External Quality Assessment (EQA) program was developed with the Royal College of Pathologists of Australasia Quality Assurance Programs (RCPAQAP). From July 2020 to May 2022, SARS-CoV-2 EQA participation ranged from 93 to 100%. Overall concordance of valid EQA results was high (98%), with improved performance following the first survey. These results are consistent with those reported by 12 Australian and 4 New Zealand laboratories for three SARS-CoV-2 RNA EQA surveys in March 2020, demonstrating that SARS-CoV-2 RNA POC testing in primary care settings can be performed to an equivalent laboratory analytical standard. More broadly, this study highlights the value of quality management practices in real-world testing environments and the benefits of ongoing EQA program participation.

15.
Clin Chem Lab Med ; 62(8): 1531-1537, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-38801089

RESUMEN

Analytical performance specifications (APS) are used for decisions about the required analytical quality of pathology tests to meet clinical needs. The Milan models, based on clinical outcome, biological variation, or state of the art, were developed to provide a framework for setting APS. An approach has been proposed to assign each measurand to one of the models based on a defined clinical use, physiological control, or an absence of quality information about these factors. In this paper we propose that in addition to such assignment, available information from all models should be considered using a risk-based approach that considers the purpose and role of the actual test in a clinical pathway and its impact on medical decisions and clinical outcomes in addition to biological variation and the state-of-the-art. Consideration of APS already in use and the use of results in calculations may also need to be considered to determine the most appropriate APS for use in a specific setting.


Asunto(s)
Control de Calidad , Humanos , Técnicas de Laboratorio Clínico/normas , Modelos Teóricos
16.
Clin Chem Lab Med ; 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38801528

RESUMEN

OBJECTIVES: This study performed an analytical validation study of the Mindray high-sensitivity cardiac troponin I (hs-cTnI) assay addressing limit of blank (LoB), limit of detection (LoD), precision, linearity, analytical specificity and sex-specific 99th percentile upper reference limits. METHODS: LoB, LoD, precision, linearity and analytical specificity were studied according to Clinical and Laboratory Standards Institute. We used one reagent lot and one CL1200i analyzer. Skeletal troponin I and T, cardiac troponin T, troponin C, actin, tropomyosin, myosin light chain, myoglobin and creatine kinase (CK-MB) were studied for cross-reactivity. Interference with biotin was examined. Lithium heparin samples (one freeze thaw cycle) from healthy males and females were measured to determine the 99th percentiles by using the non-parametric method. Analyses were performed before and after excluding subjects with clinical conditions and/or increased surrogate biomarkers. RESULTS: The Mindray hs-cTnI assay met criteria to be considered as a hs-cTn assay. LoB and LoD was <0.1 ng/L and 0.1 ng/L, respectively. Repeatability had a coefficient of variation 1.2-3.8 %, and within-laboratory imprecision 1.7-5.0 %. The measuring interval ranged from 1.1 to 28,180 ng/L. The analytical specificity was clinically acceptable for the interferents studied. After exclusions, the 99th percentile URLs obtained were 10 ng/L overall, 5 ng/L for females and 12 ng/L for males. CONCLUSIONS: Analytical observations of the Mindray hs-cTnI assay demonstrated excellent LoB, LoD, precision, linearity and analytical specificity, that were in alignment with the manufacturer's claims and regulatory guidelines for hs-cTnI. The assay is suitable for clinical investigation for patient-oriented studies.

17.
Clin Chem Lab Med ; 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38815136

RESUMEN

OBJECTIVES: This study aimed to deliver biological variation (BV) estimates for 25 types of lymphocyte subpopulations subjected to deep immunophenotyping (memory T/B cells, regulatory T cells, etc.) and classical, intermediate, and nonclassical monocyte subsets based on the full spectrum flow cytometry (FS-FCM) and a Biological Variation Data Critical Appraisal Checklist (BIVAC) design. METHODS: Samples were collected biweekly from 60 healthy Chinese adults over 10 consecutive two-week periods. Each sample was measured in duplicate within a single run for lymphocyte deep immunophenotyping and monocyte subset determination using FS-FCM, including the percentage (%) and absolute count (cells/µL). After trend adjustment, a Bayesian model was applied to deliver the within-subject BV (CVI) and between-subject BV (CVG) estimates with 95 % credibility intervals. RESULTS: Enumeration (% and cells/µL) for 25 types of lymphocyte deep immunophenotyping and three types of monocyte subset percentages showed considerable variability in terms of CVI and CVG. CVI ranged from 4.23 to 47.47 %. Additionally, CVG ranged between 10.32 and 101.30 %, except for CD4+ effector memory T cells re-expressing CD45RA. No significant differences were found between males and females for CVI and CVG estimates. Nevertheless, the CVGs of PD-1+ T cells (%) may be higher in females than males. Based on the desired analytical performance specification, the maximum allowable imprecision immune parameter was the CD8+PD-1+ T cell (cells/µL), with 23.7 %. CONCLUSIONS: This is the first study delivering BV estimates for 25 types of lymphocyte subpopulations subjected to deep immunophenotyping, along with classical, intermediate, and nonclassical monocyte subsets, using FS-FCM and adhering to the BIVAC design.

18.
Sci Rep ; 14(1): 12289, 2024 05 29.
Artículo en Inglés | MEDLINE | ID: mdl-38811684

RESUMEN

Hemoglobin A1c (HbA1c) plays a crucial role in diabetes management. We aimed to evaluate the analytical performance of a new enzymatic method kit for HbA1c measurement. The performance of the enzymatic method, including precision, accuracy, and linearity, was evaluated. Moreover, the interference effect from conventional interferents, Hb derivatives, Hb variants, and common drugs were assessed. In addition, the agreement of HbA1c results was compared between enzymatic methods, cation-exchange high-performance liquid chromatography (HPLC), and immunoassays. The intra-assay, between-assay, and total precision of HbA1c were all lower than 2%. HbA1c showed good linearity within the range of 3.96-20.23%. The enzymatic assay yielded results consistent with the external quality control samples, with a bias of less than ± 6% from the target values. The enzymatic method showed no interference from bilirubin, intralipid, vitamin C, Hb derivatives, common Hb variants, as well as antipyretic analgesics and hypoglycemic drugs. The HbA1c results of the enzymatic assay showed good agreement and accuracy compared to those obtained from the HPLC method and the immunoassay. The enzymatic method kit performed on the BS-600M chemistry analyzer is a reliable and robust method for measuring HbA1c. It is suitable for routine practice in clinical chemistry laboratories.


Asunto(s)
Pruebas de Enzimas , Hemoglobina Glucada , Hemoglobina Glucada/análisis , Humanos , Pruebas de Enzimas/métodos , Pruebas de Enzimas/normas , Cromatografía Líquida de Alta Presión/métodos , Reproducibilidad de los Resultados , Inmunoensayo/métodos , Diabetes Mellitus/sangre , Diabetes Mellitus/diagnóstico
19.
East Mediterr Health J ; 30(4): 300-303, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38808406

RESUMEN

Background: Early and accurate diagnosis is crucial for preventing the spread of SARS-CoV-2 infection. The rapid antigen test was developed for testing infection, and it was necessary to assess its performance before widespread use in Tunisia. Aim: To evaluate the effectiveness of a rapid antigen test for the detection of SARS-CoV-2 in nasopharyngeal swabs in Tunisia. Methods: Nasopharyngeal samples were taken from COVID-19 suspected cases between October and December 2020 and tested using the Standard Q COVID-19 Ag test (SD-Biosensor, Republic of Korea) and real-time reverse transcription polymerase chain reaction (RT­PCR). Results: Overall, 4539 patients were tested. Of the total study population (N = 4539), 82.5% of positive samples remained positive with the rapid antigen test, while 20.2% (470/2321) of samples that were negative with rapid antigen test were confirmed positive with RT-PCR, giving a negative predictive value of 79.8% for the rapid antigen test. The sensitivity and negative predictive value of the rapid antigen test were 70.2% and 65.8%, respectively. These results improved to 96.4% and 92.8%, respectively, when considering the cycle threshold value by RT-PCR below 25. Conclusion: Although the rapid antigen test was less sensitive than RT-PCR, its ability to rapidly detect individuals with high viral loads makes it suitable for use during an epidemic.


Asunto(s)
Prueba Serológica para COVID-19 , COVID-19 , COVID-19/diagnóstico , Reproducibilidad de los Resultados , SARS-CoV-2 , Prueba Serológica para COVID-19/normas , Nasofaringe/virología , Túnez , Prueba de Ácido Nucleico para COVID-19/normas , Sensibilidad y Especificidad , Valor Predictivo de las Pruebas , Humanos
20.
J Immunol Methods ; 528: 113666, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38574805

RESUMEN

OBJECTIVE: The clinical value of Serum amyloid A (SAA) and Lactoferrin (LTF) has received significant attention, but their detection methods are inadequate, which limits their application. This study aims to develop a dual detection method based on stable element labeling strategies and inductively coupled plasma mass spectrometry (ICP-MS) for SAA/LTF and to assess whether it can be widely used in clinical practice. METHODS: A duplex immunoassay system based on sandwich method was constructed. After optimization, methodological evaluation was performed with the guidelines of Clinical Laboratory Standards Institute (CLSI). Finally, 131 plasma samples were collected to analyze whether the new method is suitable for clinical detection. RESULTS: The LoB, LLoQ, ULoQ, and linear range of the assay were 1.09 ng/mL, 3 ng/mL, 1500 ng/mL, 3-1500 ng/mL for SAA and 0.85 ng/mL, 2 ng/mL, 1200 ng/mL, 2-1200 ng/mL for LTF respectively. The recovery rates were 95.01% to 106.26%, the intra-batch precision of low, intermediate, and high-level samples was <8%, and the inter-batch of them was <11%, the deviation of interference test results was less than±10%. The Area Under the Curve (AUC) was 0.9809 for SAA, 0.8599 for LTF, and 0.9986 for combination. CONCLUSION: The quantitative duplex immunoassay for SAA/LTF has high accuracy, good precision, and high specificity, which meets the clinical testing requirements and can be widely used in clinical practice.


Asunto(s)
Proteína Amiloide A Sérica , Inmunoensayo/métodos , Espectrometría de Masas/métodos
SELECCIÓN DE REFERENCIAS