Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
JACC Asia ; 4(6): 495-499, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39100698

RESUMEN

There are numerous approaches for transcatheter aortic valve replacement (TAVR); however, access-related complications remain a point of concern. We analyzed consecutive patients who underwent TAVR for severe aortic stenosis via the brachiocephalic artery (BCA) without sternotomy (TBc group, n = 10) and via the trans-ascending aortic (TAo group, n = 8). The median BCA diameter and distance between the access point and suprasternal notch or superior margin of the clavicle were 11.3 mm and 8.3 mm, respectively. No patients in the TBc group underwent a partial sternotomy. Compared with the TAo group, the TBc group exhibited a shorter mean procedure time and lower blood loss volume as well as shorter duration of hospitalization. TAVR through the BCA may be a safe and feasible alternative for ascending aorta access. Studies with longer follow-up analysis and more patients are warranted to confirm our findings.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39186224

RESUMEN

For the past 20 years, transcatheter aortic valve replacement (TAVR) has been the treatment of choice for symptomatic aortic stenosis. The transfemoral (TF) access is considered the gold standard approach for TAVR. However, TF-TAVR cannot be performed in some patients; thus, alternative accesses are required. Our review paper generalises the TAVR accesses currently available, including the transapical, transaortic, trans-subclavian/axillary, transcarotid, transcaval, and suprasternal approaches. Their advantages and disadvantages have been analysed. Since there is no standard recommendation for an alternative approach, access selection depends on the expertise of the local cardiac team, patient characteristics, and access properties. Each TAVR centre is recommended to master a minimum of one non-TF access alternative. Of note, more evidence is required to delve into the clinical outcomes of each approach, at both early and long-term (Figure 1).

3.
Front Cardiovasc Med ; 11: 1437626, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39175626

RESUMEN

Aortic Stenosis (AS) is a common condition with an estimated pooled prevalence of all AS in the elderly population at around 12.4%, with that of severe AS estimated to be around 3.4%. In the past, surgical aortic valve replacement was the primary treatment option for severe AS for decades. However, with the compelling evidence on the safety and efficacy of transcatheter aortic valve replacement (TAVR), it has become the gold standard treatment option for many patients with symptomatic severe AS. Transfemoral access has been the preferred method for transcatheter heart valve delivery. However, the prevalent use of TAVR on a diverse patient profile with different risk factors, such as peripheral artery disease, precluded the possibility of a transfemoral approach despite the improvement of valves and delivery systems technology. Therefore, alternative TAVR approaches have gained increasing utility in cases where transfemoral access is unfavorable. We review the journey, evolution, and techniques for different approaches of percutaneous TAVR, including transfemoral, transcarotid, transsubclavian/transaxillary, and transcaval approaches, in addition to the traditional "surgical" transaortic and transapical accesses. Consolidating these data highlights each approach's practicality and limitations, providing additional grounding for case-by-case utilization and future clinical research.

4.
Int J Mol Sci ; 25(13)2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-39000018

RESUMEN

Consecutive interactions of 3Na+ or 1Ca2+ with the Na+/Ca2+ exchanger (NCX) result in an alternative exposure (access) of the cytosolic and extracellular vestibules to opposite sides of the membrane, where ion-induced transitions between the outward-facing (OF) and inward-facing (IF) conformational states drive a transport cycle. Here, we investigate sub-state populations of apo and ion-bound species in the OF and IF states by analyzing detergent-solubilized and nanodisc-reconstituted preparations of NCX_Mj with 19F-NMR. The 19F probe was covalently attached to the cysteine residues at entry locations of the cytosolic and extracellular vestibules. Multiple sub-states of apo and ion-bound species were observed in nanodisc-reconstituted (but not in detergent-solubilized) NCX_Mj, meaning that the lipid-membrane environment preconditions multiple sub-state populations toward the OF/IF swapping. Most importantly, ion-induced sub-state redistributions occur within each major (OF or IF) state, where sub-state interconversions may precondition the OF/IF swapping. In contrast with large changes in population redistributions, the sum of sub-state populations within each inherent state (OF or IF) remains nearly unchanged upon ion addition. The present findings allow the further elucidation of structure-dynamic modules underlying ion-induced conformational changes that determine a functional asymmetry of ion access/translocation at opposite sides of the membrane and ion transport rates concurring physiological demands.


Asunto(s)
Detergentes , Conformación Proteica , Intercambiador de Sodio-Calcio , Detergentes/química , Intercambiador de Sodio-Calcio/química , Intercambiador de Sodio-Calcio/metabolismo , Intercambiador de Sodio-Calcio/genética , Iones/química , Nanoestructuras/química , Solubilidad , Animales , Espectroscopía de Resonancia Magnética/métodos
5.
J Clin Med ; 13(12)2024 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-38929915

RESUMEN

Transcatheter aortic valve replacement (TAVR) has emerged as an alternative treatment option for patients with severe aortic stenosis regardless of surgical risk, particularly in those with a high and prohibitive risk. Since the advent of TAVR, transfemoral access has been the standard of care. However, given comorbidities and anatomical limitations, a proportion of patients are not good candidates for a transfemoral approach. Alternative access, including transapical, transaortic, transaxillary, transsubclavian, transcarotid, and transcaval, can be considered. Each alternative access has advantages and disadvantages, so the vascular route should be tailored to the patient's characteristics. However, there is no standardized algorithm when choosing the optimal alternative vascular access. In this review, we analyzed the evolution and current evidence for the most common alternative access for TAVR and proposed an algorithm for choosing the optimal vascular access in this patient population.

6.
Catheter Cardiovasc Interv ; 104(1): 134-144, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38736247

RESUMEN

BACKGROUND: In transcatheter aortic valve replacement (TAVR), transfemoral (TF) access offers several advantages over alternative access routes. Advances in sheaths and valve delivery technology have catalyzed the feasibility of TF-TAVR, even in challenging anatomies. AIMS: Report procedural characteristics and outcomes of a TAVR program aiming for a 100% TF access rate. METHODS: Consecutive patients undergoing TAVR were enrolled in a prospective registry. Equipment used to facilitate TF-access in challenging anatomies included low-profile sheaths, dilatators, peripheral balloons, covered and uncovered self-expanding and balloon-expandable stents, and intravascular lithotripsy (IVL). RESULTS: A total of 400 patients with a mean age of 81 ± 6 years (42% female) were analyzed. Minimal iliofemoral artery diameter (MLD) of the main access side was <5 mm in 42 (10.5%), extreme tortuosity was present in 65 (16.3%), and severe calcification in 59 (14.8%). TF-access was successful in 399 (99.8%) patients. A transaxillary access was used in one patient. In multivariable analysis, an MLD < 5 mm was the strongest predictor for vascular complications (11.9% vs. 3.9%, OR: 3.86, 95% CI: 1.38-10.8, p = 0.01). Such patients also had more major/life-threatening bleeding (14.2% vs. 3.1%, p < 0.001) and required more planned and unplanned peripheral interventions to enable TF access (35.8% vs. 3.4%, p < 0.001). CONCLUSION: Our study shows that utilization of dedicated sheaths, peripheral balloons, stents, and IVL enables TAVR via TF access in >99% of patients. However, rates of vascular and bleeding complications in patients with narrow iliofemoral arteries (MLD < 5 mm) were high.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Cateterismo Periférico , Arteria Femoral , Punciones , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Arteria Femoral/diagnóstico por imagen , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Anciano , Cateterismo Periférico/efectos adversos , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estudios Prospectivos , Factores de Tiempo , Prótesis Valvulares Cardíacas
7.
JACC Case Rep ; 29(10): 102320, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38601848

RESUMEN

Novel dedicated devices allow transcatheter treatment of pure aortic regurgitation (AR). The JenaValve Trilogy Heart Valve System was introduced as the first dedicated and on-label AR transcatheter aortic valve replacement system, implementing a locator-based and calcium-independent anchoring mechanism. Here, we present the first-in-human transcatheter aortic valve replacement for pure AR via a transcaval access in a patient with prohibitive alternative arterial accesses.

8.
Gen Thorac Cardiovasc Surg ; 72(10): 641-648, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38460099

RESUMEN

OBJECTIVES: Transaxillary access is the most popular alternative to transfemoral transcatheter aortic valve replacement. Although left transaxillary access is generally preferred, right transaxillary transcatheter aortic valve replacement could be challenging because of the opposing axillary artery and aortic curvatures, which may warrant procedural modifications to improve alignment. Our aim is to compare our single center's outcomes for left and right transaxillary access groups and to evaluate procedural modifications for facilitating right transaxillary transcatheter aortic valve replacement. METHODS: Patient characteristics and outcomes were compared for consecutive left or right axillary TAVRs performed from 6/2016 to 6/2022 with SAPIEN 3. The effects of our previously reported "flip-n-flex" technique on procedural efficiency and new conduction disturbances were subanalyzed in the right axillary group. RESULTS: Right and left transaxillary transcatheter aortic valve replacement were performed in 25 (18 with the "flip-n-flex" technique) and 26 patients, respectively. There were no significant differences between patient characteristics or outcomes. Right axillary subanalysis showed the "flip-n-flex" technique group had significantly shorter fluoroscopy times (21.2 ± 6.2 vs 29.6 ± 12.4 min, p = 0.03) and a trend towards less permanent pacemaker implantation (6.3% vs. 42.9%, p = 0.07) compared to the group without "flip-n-flex". CONCLUSIONS: In our study, despite anatomical challenges, right transaxillary transcatheter aortic valve replacement is comparable to left access. The "flip-n-flex" technique advances right transaxillary as an appealing access for patients with few options.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Arteria Axilar , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Femenino , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Anciano , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Estudios Retrospectivos , Cateterismo Periférico/métodos , Factores de Tiempo , Prótesis Valvulares Cardíacas
11.
Interv Neuroradiol ; : 15910199231225832, 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38196319

RESUMEN

Middle meningeal artery embolization has become an important option in the management of subdural hemorrhages with multiple prospective studies demonstrating efficacy and randomized controlled trial data on the way. Access to the middle meningeal artery is usually achieved via the external carotid artery to the internal maxillary artery, then the middle meningeal artery. We report a case where a patient with symptomatic left-sided chronic subdural hemorrhage also had an external carotid artery occlusion. Direct puncture of the superficial temporal artery allowed retrograde access to the internal maxillary artery and thus the middle meningeal artery. Successful embolization of the vessel with 1:9 nBCA was performed with near total resorption of the subdural collection by 1 month postprocedure.

12.
Expert Rev Pharmacoecon Outcomes Res ; 24(2): 181-187, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37970637

RESUMEN

INTRODUCTION: The uptake of complex technologies and platforms has resulted in several challenges in the pricing and reimbursement of innovative pharmaceuticals. To address these challenges, plenty of concepts have already been described in the scientific literature about innovative value judgment or payment models, which are either (1) remaining theoretical; or (2) applied only in pilots with limited impact on patient access; or (3) applied so heterogeneously in many different countries that it prevents the health care industry from meeting expectations of HTA bodies and health care payers in the evidence requirements or offerings in different jurisdictions. AREAS COVERED: This paper provides perspectives on how to reduce the heterogeneity of pharmaceutical payment models across European countries in five areas, including 1) extended evaluation frameworks, 2) performance-based risk-sharing agreements, 3) pooled procurement for low volume or urgent technologies, 4) alternative access schemes, and 5) delayed payment models for technologies with high upfront costs. EXPERT OPINION: Whilst pricing and reimbursement decisions will remain a competence of EU member states, there is a need for alignment of European pharmaceutical payment model components in critical areas with the ultimate objective of improving the equitable access of European patients to increasingly complex pharmaceutical technologies.


Asunto(s)
Costos de los Medicamentos , Tecnología Farmacéutica , Humanos , Costos y Análisis de Costo , Europa (Continente) , Preparaciones Farmacéuticas
13.
JACC Case Rep ; 26: 102069, 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-38094178

RESUMEN

We present a series of 2 high-risk surgical patients undergoing transcatheter aortic valve replacement via alternative access owing to unacceptable transfemoral options. Both patients underwent percutaneous transcarotid access with successful valve delivery and deployment without notable complication. To our knowledge, this approach has not been previously reported. (Level of Difficulty: Intermediate.).

14.
J Invasive Cardiol ; 35(7): E355-E364, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37769621

RESUMEN

BACKGROUND: Percutaneous transaxillary access is used as an alternative to the transfemoral approach for transcatheter aortic valve implantation in patients with severe peripheral vascular disease. The left transaxillary approach is usually preferred due to ease of valve alignment with the aortic annulus. Some patients have anatomical and physiological factors which preclude this approach. Moreover, most catheterization lab layouts make left-sided approaches to the heart awkward for imaging, visualization, procedural ease, and radiation protection. AIMS: The authors describe novel adaptations to allow successful right transaxillary access for implantation of the transcatheter heart valve using the Edwards Sapien 3 system (Edwards Lifesciences). METHODS: We searched our local structural heart database for all patients who underwent transcatheter aortic valve implantation via axillary access, from January 2021 to January 2022. Patients with left axillary access were excluded. RESULTS: We report 6 percutaneous right transaxillary cases performed in the last year using steps which allow smooth delivery of the SAPIEN 3 Ultra valve down the greater curvature of the aorta and providing co-axial alignment of the valve. Only one patient had a vascular complication with arterial dissection at the closure point managed with 8 mm x 37 mm Bentley uncovered stent at the access site. CONCLUSION: With the modifications described in our article, the right transaxillary approach has now become our preferred secondary access route for TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Catéteres , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Diseño de Prótesis
15.
Innovations (Phila) ; 18(4): 326-330, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37551700

RESUMEN

Alternative access transcatheter aortic valve replacement (TAVR) consists primarily of 4 different options: transcaval, transaxillary, transcarotid, and transapical. While many centers have a preferred alternative access site, few papers have compared the outcomes of TAVR with each alternative access site. In this review, we examine the outcomes of TAVR at each alternative access site, focusing on mortality, stroke, bleeding, pacemaker insertion, paravalvular leakage, and discharge to home. Notable findings include higher mortality in the transapical group and higher stroke rate in the transaxillary group. On the basis of these data, we suggest that transcarotid TAVR might represent the second choice of approach for TAVR when alternate access is required.


Asunto(s)
Estenosis de la Válvula Aórtica , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento , Accidente Cerebrovascular/epidemiología
16.
J Am Heart Assoc ; 12(12): e028878, 2023 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-37301759

RESUMEN

Background Peripheral vascular intervention (PVI) is occasionally required to facilitate delivery system insertion or to treat vascular complications during transfemoral transcatheter aortic valve replacement (TF-TAVR). However, the impact of PVI on outcomes is not well understood. Therefore, we aimed to compare outcomes between TF-TAVR with versus without PVI and between TF-TAVR with PVI versus non-TF-TAVR. Methods and Results We retrospectively reviewed 2386 patients who underwent TAVR with a balloon-expandable valve at a single institution from 2016 to 2020. The primary outcomes were death and major adverse cardiac/cerebrovascular event (MACCE), defined as death, myocardial infarction, or stroke. Of 2246 TF-TAVR recipients, 136 (6.1%) required PVI (89% bailout treatment). During follow-up (median 23.0 months), there were no significant differences between TF-TAVR with and without PVI in death (15.4% versus 20.7%; adjusted HR [aHR], 0.96 [95% CI, 0.58-1.58]) or MACCE (16.9% versus 23.0%; aHR, 0.84 [95% CI, 0.52-1.36]). However, compared with non-TF-TAVR (n=140), TF-TAVR with PVI carried significantly lower rates of death (15.4% versus 40.7%; aHR, 0.42 [95% CI, 0.24-0.75]) and MACCE (16.9% versus 45.0%; aHR, 0.40 [95% CI, 0.23-0.68]). Landmark analyses demonstrated lower outcome rates following TF-TAVR with PVI than non-TF-TAVR both within 60 days (death 0.7% versus 5.7%, P=0.019; MACCE 0.7% versus 9.3%; P=0.001) and thereafter (death 15.0% versus 38.9%, P=0.014; MACCE 16.5% versus 41.3%, P=0.013). Conclusions The need for PVI during TF-TAVR is not uncommon, mainly due to the bailout treatment for vascular complications. PVI is not associated with worse outcomes in TF-TAVR recipients. Even when PVI is required, TF-TAVR is associated with better short- and intermediate-term outcomes than non-TF-TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Arteria Femoral/cirugía
17.
J Clin Med ; 12(9)2023 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-37176697

RESUMEN

Background: Endovascular thrombectomy (EVT) through femoral access is difficult to perform in some patients with acute ischemic stroke due to challenging vasculature. We compared outcomes of EVT through femoral versus alternative arterial access. Methods: In this observational study, we included patients from the MR CLEAN Registry who underwent EVT for acute ischemic stroke in the anterior circulation between 2014 and 2019 in the Netherlands. Patients who underwent EVT through alternative and femoral access were matched on propensity scores in a 1:3 ratio. The primary endpoint was favorable functional outcome (modified Rankin Scale score ≤ 2) at 90 days. Secondary endpoints were early neurologic recovery, mortality, successful intracranial reperfusion and puncture related complications. Results: Of the 5197 included patients, 17 patients underwent EVT through alternative access and were matched to 48 patients who underwent EVT through femoral access. Alternative access was obtained through the common carotid artery (n = 15/17) and brachial artery (n = 2/17). Favorable functional outcome was less often observed after EVT through alternative than femoral access (18% versus 27%; aOR, 0.36; 95% CI, 0.05-2.74). The rate of successful intracranial reperfusion was higher for alternative than femoral access (88% versus 58%), although mortality (59% versus 31%) and puncture related complications (29% versus 0%) were more common after alternative access. Conclusions: EVT through alternative arterial access is rarely performed in the Netherlands and seems to be associated with worse outcomes than standard femoral access. A next step would be to compare the additional value of EVT through alternative arterial access after failure of femoral access.

18.
JACC Cardiovasc Interv ; 16(4): 396-411, 2023 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-36858659

RESUMEN

BACKGROUND: The optimal access route in patients with severe peripheral artery disease (PAD) undergoing transcatheter aortic valve replacement (TAVR) remains undetermined. OBJECTIVES: This study sought to compare clinical outcomes with transfemoral access (TFA), transthoracic access (TTA), and nonthoracic transalternative access (TAA) in TAVR patients with severe PAD. METHODS: Patients with PAD and hostile femoral access (TFA impossible, or possible only after percutaneous treatment) undergoing TAVR at 28 international centers were included in this registry. The primary endpoint was the propensity-adjusted risk of 30-day major adverse events (MAE) defined as the composite of all-cause mortality, stroke/transient ischemic attack (TIA), or main access site-related Valve Academic Research Consortium 3 major vascular complications. Outcomes were also stratified according to the severity of PAD using a novel risk score (Hostile score). RESULTS: Among the 1,707 patients included in the registry, 518 (30.3%) underwent TAVR with TFA after percutaneous treatment, 642 (37.6%) with TTA, and 547 (32.0%) with TAA (mostly transaxillary). Compared with TTA, both TFA (adjusted HR: 0.58; 95% CI: 0.45-0.75) and TAA (adjusted HR: 0.60; 95% CI: 0.47-0.78) were associated with lower 30-day rates of MAE, driven by fewer access site-related complications. Composite risks at 1 year were also lower with TFA and TAA compared with TTA. TFA compared with TAA was associated with lower 1-year risk of stroke/TIA (adjusted HR: 0.49; 95% CI: 0.24-0.98), a finding confined to patients with low Hostile scores (Pinteraction = 0.049). CONCLUSIONS: Among patients with PAD undergoing TAVR, both TFA and TAA were associated with lower 30-day and 1-year rates of MAE compared with TTA, but 1-year stroke/TIA rates were higher with TAA compared with TFA.


Asunto(s)
Ataque Isquémico Transitorio , Enfermedad Arterial Periférica , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Resultado del Tratamiento , Sistema de Registros
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA