Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Cureus ; 14(7): e26864, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35974851

RESUMEN

Introduction Postoperative infections represent a substantial burden to patients and healthcare systems. To improve patient care and reduce healthcare expenditures, interventions to reduce surgical infections must be employed. The crystalline C-band ultraviolet (UV-C) air filtration technology (Aerobiotix Inc., Miamisburg, OH, USA) has been designed to reduce airborne bioburden through high-quality filtration and germicidal irradiation. The purpose of this study was to assess the ability of a novel UV-C air filtration device to reduce airborne particle counts and contamination of surgical instrument trays in an operating room (OR) setting. Materials and methods Thirty sterile instrument trays were opened in a positive-air-flow OR. The trays were randomly assigned to one of two groups (UV-C or control, n=15 per group). In the UV-C group, the UV-C filtration device was used and in the control, it was not. All trays were opened with the use of a sterile technique and left exposed in the OR for four hours. Air was sampled by a particle counter to measure the numbers of 5µm and 10µm particles. Culture specimens were obtained from the trays to assess for bacterial contamination. Outcome data were collected at 30-minute intervals for the duration of the four-hour study period. Results Use of the UV-C device resulted in statistically significant reductions in the numbers of 5µm (average of 64.9% reduction when compared with the control, p<0.001) and 10µm (average of 65.7% reduction when compared with the control, p<0.001)-sized particles detectable in the OR. There was no significant difference in the overall rates of contamination (33.3% in the control group vs. 26.7% in the UV-C group, p=1.0) or the time to contamination (mean survival of 114 minutes in the control group vs. 105 minutes in the UV-C group, p=0.72) of surgical instrument trays with the use of the UV-C device. Conclusions The results demonstrate that the UV-C filtration device can successfully reduce airborne bioburden in standard ORs, suggesting that it may have the potential to reduce the risk for wound and hardware infections. Further clinical trials are necessary to better determine the effect of this air filtration system on postoperative infection rates.

2.
J Hosp Infect ; 126: 116-122, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35569577

RESUMEN

OBJECTIVE: Data on the transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) remain conflicting. Airborne transmission is still debated. However, hospital risk control requires better understanding of the different modes of transmission. This study aimed to evaluate the frequency of, and factors associated with, environmental air and surface contamination in the rooms of patients with coronavirus disease 2019 in the acute phase of the disease. METHODS: Sixty-five consecutive patients were included in this study. For each patient, seven room surfaces, air 1 m and 3 m from the patient's head, the inner surface of the patient's mask, and the outer surface of healthcare workers' (HCW) masks were sampled. Environmental contamination was assessed by quantitative reverse transcription polymerase chain reaction (RT-qPCR) for SARS-CoV-2 RNA on surfaces, air and masks. A viral isolation test was performed on Vero cells for samples with an RT-qPCR cycle threshold (Ct) ≤37. RESULTS: SARS-CoV-2 RNA was detected by RT-qPCR in 34%, 12%, 50% and 10% of surface, air, patient mask and HCW mask samples, respectively. Infectious virus was isolated in culture from two samples among the 85 positive samples with Ct ≤37. On multi-variate analysis, only a positive result for SARS-CoV-2 RT-qPCR for patients' face masks was found to be significantly associated with surface contamination (odds ratio 5.79, 95% confidence interval 1.31-25.67; P=0.025). CONCLUSION: This study found that surface contamination by SARS-CoV-2 was more common than air and mask contamination. However, viable virus was rare. The inner surface of a patient's mask could be used as a marker to identify those at higher risk of contamination.


Asunto(s)
COVID-19 , SARS-CoV-2 , Animales , Chlorocebus aethiops , Hospitales , Humanos , Habitaciones de Pacientes , ARN Viral , Células Vero
3.
Nanomaterials (Basel) ; 12(3)2022 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-35159728

RESUMEN

The aging in air inevitably results in the accumulation of airborne hydrocarbon contaminations on a graphene surface, which causes considerable difficulties in the subsequent application of graphene. Herein, we report an electron-beam-activated fluorination/defluorination cycle for achieving a long-term preservation of CVD graphene. After experiencing such cycle, the accumulation of airborne hydrocarbon on the graphene surfaces is strongly reduced, and the initial chemical status of graphene can be restored, which is confirmed by employing atomic force microscopy and X-ray photoelectron microscopy. Our reported approach provides an efficient method for the cleaning and long-term preservation of graphene, and it is particularly useful for graphene microscopy characterizations.

4.
J Hosp Infect ; 119: 9-15, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34619268

RESUMEN

BACKGROUND: Surgical site infections after total hip and knee replacement are linked to the quality of the operating room (OR) air. Applying tight occlusive clothing, effective ventilation and correct working methods are key concepts to obtain low bacterial concentrations in the OR air. The dry penetration test referred to in European standard EN 13795-2:2019 is a screening method for materials used in surgical clothing. Source strength, defined as the dispersal of bacteria-carrying particles from persons during activity, is a functional test of clothing systems and has been calculated in a dispersal chamber and in ORs. Results from both tests can be used when comparing surgical clothing systems. AIM: This study relates results of dry penetration tests to source strength values for five surgical clothing systems available on the Swedish market. METHODS: Experimental data are reported on the function of these products, expressed as source strength calculated from results in a dispersal chamber and in ORs during orthopaedic operations. FINDINGS: All materials tested with dry penetration ≤50 colony-forming units (cfu) had source strength values <3 cfu/s for one person in the dispersal chamber, whereas the material of one product when laundered >50 times had source strength in the dispersal chamber of up to 8 cfu/s. CONCLUSION: The dry penetration test could predict the performance of clean air suits of the same design, but more studies are needed to obtain a more valid correlation. Requirements of source strength should be included in standards.


Asunto(s)
Microbiología del Aire , Quirófanos , Bacterias , Contaminación de Medicamentos , Humanos , Infección de la Herida Quirúrgica , Ventilación
5.
J Hosp Infect ; 113: 85-95, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33930488

RESUMEN

BACKGROUND: Without confirmation of the ventilation design conditions (typology and airflow rate), the common practice of identifying unidirectional airflow (UDAF) systems as equivalent to ultra-clean air ventilation systems may be misleading, but also any claims about the ineffectiveness of UDAF systems should be doubted. The aim of this review was to assess and compare ventilation system design conditions for which ultra-clean air (mean <10 cfu/m3) within 50 cm from the wound has been reported. Six medical databases were systematically searched to identify and select studies reporting intraoperative airborne levels expressed as cfu/m3 close to the wound site, and ventilation system design conditions. Available data on confounding factors such as the number of persons present in the operating room, number of door openings, and clothing material were also included. Predictors for achieving mean airborne bacteria levels within <10 cfu/m3 were identified using a penalized multivariate logistic regression model. Twelve studies met the eligibility criteria and were included for analysis. UDAF systems considered had significantly higher air volume flows compared with turbulent ventilation (TV) systems considered. Ultra-clean environments were reported in all UDAF-ventilated (N = 7) rooms compared with four of 11 operating rooms equipped with TV. On multivariate analysis, the total number of air exchange rates (P=0.019; odds ratio (OR) 95% confidence interval (CI): 0.66-0.96) and type of clothing material (P=0.031; OR 95% CI: 0.01-0.71) were significantly associated with achieving mean levels of airborne bacteria <10 cfu/m3. High-volume UDAF systems complying with DIN 1946-4:2008 standards for the airflow rate and ceiling diffuser size unconditionally achieve ultra-clean air close to the wound site. In conclusion, the studied articles demonstrate that high-volume UDAF systems perform as ultra-clean air systems and are superior to TV systems in reducing airborne bacteria levels close to the wound site.


Asunto(s)
Microbiología del Aire , Ventilación , Aire Acondicionado , Bacterias , Humanos , Quirófanos , Infección de la Herida Quirúrgica/prevención & control
7.
Nano Lett ; 20(8): 5670-5677, 2020 08 12.
Artículo en Inglés | MEDLINE | ID: mdl-32579374

RESUMEN

Previous studies indicate that 2D materials such as graphene, WS2, and MoS2 deposited on oxidized silicon substrate are susceptible to aging due to the adsorption of airborne contamination. As a result, their surfaces become more hydrophobic. However, it is not clear how ubiquitous such a hydrophobization is, and the interplay between the specific adsorbed species and resultant wetting aging remains elusive. Here, we report a pronounced and general hydrophilic-to-hydrophobic wetting aging on 2D InSe films, which is independent of the substrates to synthesize these films (silicon, glass, nickel, copper, aluminum oxide), though the extent of wetting aging is sensitive to the layer of films. Our findings are ascribed to the occurrence and enrichment of airborne contamination that contains alkyl chains. Our results also suggest that the wetting aging effect might be universal to a wide range of 2D materials.

8.
Environ Sci Pollut Res Int ; 26(19): 19632-19645, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31079297

RESUMEN

Pesticides have been associated with various pathologies, and there is growing evidence of pesticide presence in domestic environments. However, most available studies focused on a limited number of pesticides or households, and few have been conducted in Europe. We aimed to assess indoor pesticide contamination by screening the prevalence of 276 pesticides and ten pesticide metabolites, in French households from different agricultural and urban areas. We sampled indoor dust from 239 households in 2012, proximate to orchards (n = 69), cereals (n = 66) and vineyard (n = 68) crops, or from urban area (n = 36). we used cellulose wipes moistened with isopropanol and polypropylene dust traps to collect recent (7 and 30 days, respectively) and settled dust (> 6 months). Overall, 125 pesticides and piperonyl butoxide were detected at least once in households, mostly at low prevalence: 97 in recent dust, and 111 in settled dust. In recent dust, the most prevalent compounds were o-phenylphenol (168 households, 70%), pentachlorophenol (86, 36%), and piperonyl butoxide (82, 34%). In addition to agricultural pesticides, we found a high proportion of domestic and banned compounds in recent and settled house dust. Several pesticides were identified in house dust, from different pesticide groups and sources. Our results suggest that domestic usage and persistence of banned pesticides may contribute substantially to indoor pesticide contamination. Graphical abstract 97 pesticides detected in households' recent indoor dust.


Asunto(s)
Contaminación del Aire Interior/análisis , Producción de Cultivos , Polvo/análisis , Monitoreo del Ambiente/métodos , Vivienda/normas , Plaguicidas/análisis , Francia , Humanos
9.
Asian Pac Isl Nurs J ; 4(1): 11-19, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31037269

RESUMEN

Post anesthesia care units (PACU) are sanitary spaces at hospitals. Bacterial and fungal contaminants in ambient air can pose significant threats to patient recovery. Excess waste anesthetic gases such as nitrous oxide and desflurane can also pose reproductive, genetic, and other health risks to PACU staff who suffer longterm exposure. Healthcare institutions routinely monitor and study PACU air quality as required by occupational health and safety acts and related regulations, and professional standards of care. This study presents recent data from a PACU intervention at Rajavithi Hospital in Bangkok, Thailand. Rajavithi took measurements of concentrations of airborne fungi, bacteria, desflurane, and nitrous oxide before and after installation of a new ventilation system. Concurrently, the hospital surveyed employees before and after a hazard communication and conducted a training campaign in efforts to understand employee attitudes toward health and safety procedures, and to increase their perceived importance of several PACU-specific protocols. Results showed bacterial contamination fell from 1,307 CFU/m3 to 182 CFU/m3, fungi fell from 70.4 CFU/m3 to 35.8 CFU/m3, desflurane fell from 0.25 ppm to 0.21 ppm, and nitrous oxide fell from 21.86 ppm to 20.47 ppm during the intervention while PACU worker attitudes toward health and safety improved. Additional monitoring, communication, and training are recommended for Rajavithi and other healthcare institutions.

10.
J Environ Radioact ; 192: 543-550, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30138850

RESUMEN

From late September to early October of 2017, the majority of European networks involved in environmental radiological monitoring - including the environmental monitoring system of the KFKI Campus in Budapest - detected 106Ru isotope of artificial origin in the atmosphere. The reported values higher than the minimum detectable activity (MDA) concentrations were in the range of 0.8 µBq/m3 - 145 mBq/m3. Based on the results of environmental measurements and the available meteorological data, assessments were made to analyze concentration levels of 106Ru activity and to help understand the behavior of radioruthenium in various environmental media. Evaluation of the daily variation of activity levels indicated a maximum of 4 day-long residence time of 106Ru contamination presence in ground level air in Budapest. An average 106Ru activity concentration of 25.6 ±â€¯1.4 mBq/m3 have been observed for the estimated residence time of 106Ru in the air. Deposition of 106Ru was dominantly influenced by rainfall, the major contributor wet deposition which led to an average of 11.3 ±â€¯1.3 Bq/m2 deposition on the ground surface prior to plume passage.


Asunto(s)
Contaminantes Radiactivos del Aire/análisis , Dosis de Radiación , Monitoreo de Radiación , Rutenio/análisis , Atmósfera/química , Hungría
12.
ACS Appl Mater Interfaces ; 10(26): 22520-22528, 2018 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-29812895

RESUMEN

The thickness of graphene films can be accurately determined by optical contrast spectroscopy. However, this becomes challenging and complicated when the flake size reduces to the micrometer scale, where the contrast spectrum is sensitively dependent on the polarization and incident angle of light. Here, we report accurate measurement of the optical contrast spectra of micrometer-sized few-layer graphene flakes on Au substrate. Using a high-resolution optical microscopy with a 100× magnification objective, we accurately determined the layer numbers of flakes as small as one micrometer in lateral size. We developed a theoretical model to accurately take into account the appropriate contribution of light incident at various angles and polarizations, which matched the experimental results extremely well. Furthermore, we demonstrate that the optical contrast spectroscopy is highly sensitive to detect the adsorption of submonolayer airborne hydrocarbon molecules, which can reveal whether graphene is contaminated. Though the technique was demonstrated on graphene, it can be readily generalized to many other two-dimensional materials, which opens new avenues for developing miniaturized and ultrasensitive label-free molecular sensors.

13.
Am J Infect Control ; 45(1): 39-41, 2017 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-27665035

RESUMEN

BACKGROUND: Aspergillus fumigatus is a major opportunistic pathogen causing nosocomial infection. Hospital outbreaks of invasive aspergillosis have been associated with demolition and building construction. This study was designed to examine the impact of meteorologic factors and different periods of work on outdoor fungal airborne concentrations. METHODS: The study was conducted at Necker Enfants Malades Hospital, a 650-bed teaching care hospital recently involved in a large construction program, including renovation, construction, and demolition. During the work phases, prospective external air samplings were performed 3 times a week, and meteorologic parameters were collected every day. RESULTS: Two hundred and one samples were collected. Aspergillus spp were found in 80.1% of samples, with a median concentration of 16 colony forming units (CFU)/m3. A significant increase in the colony count of molds occurred after demolition. In the multivariate analysis, factors associated with overall fungi concentration were the type of work construction and temperature. Elevated Aspergillus spp concentrations (>20 CFU/m3) were associated with higher temperature. CONCLUSIONS: Our findings underline the importance of environmental surveillance. According to our results we suggest that demolition work should be performed during the winter and fall seasons.


Asunto(s)
Microbiología del Aire , Aspergillus fumigatus/aislamiento & purificación , Monitoreo del Ambiente/métodos , Arquitectura y Construcción de Hospitales , Aspergilosis/prevención & control , Francia , Hospitales de Enseñanza , Humanos , Control de Infecciones/métodos , Estudios Prospectivos
14.
Orthop Traumatol Surg Res ; 101(1 Suppl): S77-83, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25623269

RESUMEN

Surgical-site infections (SSIs) due to intra-operative contamination are chiefly ascribable to airborne particles carrying microorganisms, mainly Staphylococcus aureus, which settle on the surgeon's hands and instruments. SSI prevention therefore rests on minimisation of airborne contaminated particle counts, although these have not been demonstrated to correlate significantly with SSI rates. Maintaining clear air in the operating room classically involves the use of ultra clean ventilation systems combining laminar airflow and high-efficiency particulate air filters to create a physical barrier around the surgical table; in addition to a stringent patient preparation protocol, appropriate equipment, and strict operating room discipline on the part of the surgeon and other staff members. SSI rates in clean surgery, although influenced by the type of procedure and by patient-related factors, are consistently very low, of about 1% to 2%. These low rates, together with the effectiveness of prophylactic antibiotic therapy and the multiplicity of parameters influencing the SSI risk, are major obstacles to the demonstration that a specific measure is effective in decreasing SSIs. As a result, controversy surrounds the usefulness of many measures, including laminar airflow, body exhaust suits, patient preparation techniques, and specific surgical instruments. Impeccable surgical technique and operating room behaviour, in contrast, are clearly essential.


Asunto(s)
Infección de la Herida Quirúrgica/prevención & control , Filtros de Aire , Microbiología del Aire , Contaminación del Aire Interior , Antiinfecciosos Locales/uso terapéutico , Profilaxis Antibiótica , Contaminación de Equipos , Desinfección de las Manos , Humanos , Quirófanos , Tempo Operativo , Cuidados Preoperatorios , Ropa de Protección
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA