Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Front Nutr ; 11: 1280425, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38385007

RESUMEN

Background: While several methodologies are available to measure adiposity, few have been validated in sub-Saharan African (SSA) and none in postpartum African women living with HIV (WLHIV). We compared bioelectrical impendence analysis (BIA) and air displacement plethysmography (ADP) against dual x-ray absorptiometry (DXA) in South African women and examined differences by HIV and body mass index (BMI) status. Methods: Lin's concordance correlation coefficient (CCC) test was used to examine fat mass (FM), fat free mass (FFM), and total body fat percent (%BF) difference between BIA vs. DXA, and ADP vs. DXA in women living with HIV (n = 57) and without HIV (n = 25). The Bland Altman test was used to assess mean differences and the direction of bias. Results: The median age was 31 years (IQR, 26-35) and months postpartum were 11 (IQR, 7-16), 44% of the women had obesity. Lin's CCC for BIA and ADP vs. DXA were both 0.80 for %BF and 0.97 for FM, and 0.86 and 0.80 for FFM, respectively. Mean differences (DXA-BIA and ADP estimates) were 0.22 ± 4.54% (p = 0.54) and 3.35 ± 3.27% (p < 0.01) for %BF, -0.82 ± 3.56 kg (p = 0.06) and 1.43 ± 2.68 kg (p = 0.01) for FM, -1.38 ± 3.61 kg (p = 0.01) and - 3.34 ± 2.37 kg (p < 0.01) for FFM, respectively. BIA overestimated %BF in WLHIV and underestimated it in women with obesity. Conclusion: Body composition measurements using BIA and ADP correlated well with DXA, thereby providing alternative, safe tools for measuring postpartum FM and FFM in SSA women, including WLHIV.

2.
Front Nutr ; 9: 980790, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36313113

RESUMEN

Background: Bioelectrical impedance analysis (BIA) is widely used to measure body composition but has not been adequately evaluated in infancy. Prior studies have largely been of poor quality, and few included healthy term-born offspring, so it is unclear if BIA can accurately predict body composition at this age. Aim: This study evaluated impedance technology to predict fat-free mass (FFM) among a large multi-ethnic cohort of infants from the United Kingdom, Singapore, and New Zealand at ages 6 weeks and 6 months (n = 292 and 212, respectively). Materials and methods: Using air displacement plethysmography (PEA POD) as the reference, two impedance approaches were evaluated: (1) empirical prediction equations; (2) Cole modeling and mixture theory prediction. Sex-specific equations were developed among ∼70% of the cohort. Equations were validated in the remaining ∼30% and in an independent University of Queensland cohort. Mixture theory estimates of FFM were validated using the entire cohort at both ages. Results: Sex-specific equations based on weight and length explained 75-81% of FFM variance at 6 weeks but only 48-57% at 6 months. At both ages, the margin of error for these equations was 5-6% of mean FFM, as assessed by the root mean squared errors (RMSE). The stepwise addition of clinically-relevant covariates (i.e., gestational age, birthweight SDS, subscapular skinfold thickness, abdominal circumference) improved model accuracy (i.e., lowered RMSE). However, improvements in model accuracy were not consistently observed when impedance parameters (as the impedance index) were incorporated instead of length. The bioimpedance equations had mean absolute percentage errors (MAPE) < 5% when validated. Limits of agreement analyses showed that biases were low (< 100 g) and limits of agreement were narrower for bioimpedance-based than anthropometry-based equations, with no clear benefit following the addition of clinically-relevant variables. Estimates of FFM from BIS mixture theory prediction were inaccurate (MAPE 11-12%). Conclusion: The addition of the impedance index improved the accuracy of empirical FFM predictions. However, improvements were modest, so the benefits of using bioimpedance in the field remain unclear and require further investigation. Mixture theory prediction of FFM from BIS is inaccurate in infancy and cannot be recommended.

3.
Nutrients ; 14(5)2022 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-35268047

RESUMEN

The evaluation of body composition (BC) is relevant in the evaluation of children's health-disease states. Different methods and devices are used to estimate BC. The availability of methods and the clinical condition of the patient usually defines the ideal approach to be used. In this cross-sectional study, we evaluate the accuracy of different methods to estimate BC in Mexican children and adolescents, using the 4-C model as the reference. In a sample of 288 Mexican children and adolescents, 4-C body composition assessment, skinfold-thickness (SF), dual-energy X-ray absorptiometry (DXA), air displacement plethysmography (ADP), and deuterium dilution (D2O) were performed, along with MRI in a subsample (52 participants). The analysis of validity was performed by correlation analysis, linear regression, and the Bland-Altman method. All methods analyzed showed strong correlations for FM with 4-C values and between each other; however, DXA and MRI overestimated FM, whereas skinfolds and ADP under-estimated FM. Conclusion: The clinical assessment of BC by means of SF, ADP, DXA, MRI and D2O correlated well with the 4-C model and between them, providing evidence of their clinical validity and utility. The results from different methods are not interchangeable. Preference between methods may depend on their availability and the specific clinical setting.


Asunto(s)
Composición Corporal , Pletismografía , Absorciometría de Fotón/métodos , Adolescente , Niño , Estudios Transversales , Óxido de Deuterio , Humanos , Imagen por Resonancia Magnética , Pletismografía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA