1.
Indian J Crit Care Med ; 28(8): 726-728, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39239190

RESUMEN

How to cite this article: Pachisia AV, Govil D. High Flow, High Hope: HFNO in Acute Hypoxemic Respiratory Failure. Indian J Crit Care Med 2024;28(8):726-728.

2.
J Neonatal Perinatal Med ; 17(4): 589-595, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38968059

RESUMEN

BACKGROUND: Thoracoabdominal asynchrony (TAA) is commonly seen in preterm infants. Respiratory inductive plethysmography (RIP) is a noninvasive way to objectively assess work of breathing (WOB) indices. The impact of bronchopulmonary dysplasia (BPD) on TAA at discharge has not been established. The aim of this study is to compare WOB indices in premature infants with a diagnosis of BPD to premature infants without a diagnosis of BPD at discharge. METHODS: A prospective, observational study of premature infants (<32 weeks gestation) at discharge during quiet breathing in the supine position. RIP noninvasively measured WOB indices. A high-resolution pulse oximeter collected oxygen saturation and heart rate data. RESULTS: This study included thirty-one infants with BPD and thirty-four infants without BPD. Infants diagnosed with BPD had increased phase angle [BPD Φ = 73 . 90 (8.2) vs NoBPD Φ = 52.6 (8.2), p = 0.039]. Infants diagnosed with BPD had decreased saturations [BPD SpO2 = 96% (0.4) vs NoBPD Sp02 98% (0.3), p=<0.001], increased time with saturations less than 85% [BPD % =2.74 (0.7) vs NoBPD % =0.91 (0.4), p = .018], and increased time with saturations less than 80% [BPD % =1.57 (0.5) vs NoBPD % =0.52 (0.3), p = 0.045]. There was no difference in heart rate or breaths per minute for infants with BPD versus controls. CONCLUSION: Premature infants with BPD demonstrated increased TAA and had lower saturations compared to infants without BPD at discharge despite being chronologically older and being discharged at an older corrected gestational age. The impact of BPD on breathing patterns persists at discharge and suggests these patients may have residual lung and/or respiratory muscle dysfunction.


Asunto(s)
Displasia Broncopulmonar , Recien Nacido Prematuro , Oximetría , Saturación de Oxígeno , Pletismografía , Trabajo Respiratorio , Humanos , Displasia Broncopulmonar/fisiopatología , Recién Nacido , Masculino , Femenino , Estudios Prospectivos , Pletismografía/métodos , Saturación de Oxígeno/fisiología , Oximetría/métodos , Trabajo Respiratorio/fisiología , Alta del Paciente/estadística & datos numéricos , Frecuencia Cardíaca/fisiología , Estudios de Casos y Controles , Edad Gestacional
3.
Pediatr Pulmonol ; 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39056530

RESUMEN

BACKGROUND: A high-flow nasal cannula (cHFNC) delivers flow continuously (during inspiration and expiration). Using the diaphragm electrical activity (Edi), synchronizing HFNC could be an alternative (cycling high/low flow on inspiration/expiration, respectively). The objective of this study was to demonstrate the feasibility of synchronized HFNC (sHFNC) and compare it to cHFNC. METHODS: Different levels of cHFNC and sHFNC (4, 6, 8, and 10 liters per minute [LPM], with 2 LPM on expiration for sHFNC) were compared in eight rabbits (mean weight 3.16 kg), before and after acute lung injury (pre-ALI and post-ALI). Edi, tracheal pressure (Ptr), esophageal pressure (Pes), flow, and arterial CO2 were measured. In addition to the animal study, one 3.52 kg infant received sHFNC and cHFNC using a Servo-U ventilator. RESULTS: In the animal study, there were more pronounced decreases in Edi, reduced Pes swings and reduced PaCO2 at comparable flows during sHFNC compared to cHFNC both pre and post-ALI (p < .05). Baseline (pre-inspiratory) Ptr was 2-7 cmH2O greater during cHFNC (p < .05) indicating more dynamic hyperinflation. In one infant, the ventilator performed as expected, delivering Edi-synchronized high/low flow. CONCLUSION: Synchronizing high flow unloaded breathing, decreased Edi, and reduced PaCO2 in an animal model and is feasible in infants.

4.
Intensive Care Med Exp ; 12(1): 63, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38976100

RESUMEN

PURPOSE: Tracheostomized patients often present with muscle weakness, altered consciousness, or swallowing difficulties. Hence, the literature is scarce regarding the challenging management of tracheostomy weaning. There is a need to strengthen the understanding of respiratory mechanisms with the different tracheostomy tube modalities that compose this weaning pathway. We aimed to evaluate the impact of these modalities on the work of breathing (WOB), total positive end-expiratory pressure (PEEPtot), and tidal volume (VT). METHODS: With a three-dimensional (3D) printed head mimicking human upper airways, we added a tracheal extension, and pierced to allow insertion of a size 7.0 tracheostomy cannula. The whole was connected to an artificial lung. Three lung mechanics were simulated (normal, obstructive and restrictive). We compared five different tracheostomy tube modalities to a control scenario in which the tube was capped and the cuff was deflated. RESULTS: A marginal difference was observed on the WOB within conditions with a slight increase + 0.004 [95% CI (0.003-0.004); p < 0.001] when the cuff was inflated in the normal and restrictive models and a slight decrease in the obstructive model. The highest PEEPtot that was reached was + 1 cmH2O [95% CI (1-1.1); p < 0.001] with high-flow therapy (HFT) with the cuff inflated in the obstructive model. We observed a statistically significant reduction in VT [up to - 57 mL 95% CI (- 60 to - 54); p < 0.001] when the cuff was inflated, in both the normal and obstructive models. CONCLUSIONS: Our results support the use of conditions that involve cuff deflation. Intermediate modalities with the cuff deflated produced similar results than cannula capping.

5.
Artículo en Inglés | MEDLINE | ID: mdl-39048473

RESUMEN

OBJECTIVE: The primary objective of this study was to evaluate the impact of high-flow nasal cannula oxygen therapy [HFNC] on the diaphragm thickening fraction. DESIGN: Prospective, descriptive, cohort study SETTING: The study was conducted in the Physiology and Respiratory Care Laboratory, Intensive Care Unit, Hospital Británico de Buenos Aires. PARTICIPANTS: Thirteen healthy subjects >18 years old INTERVENTIONS: High-flow nasal cannula oxygen therapy MAIN VARIABLES OF INTEREST: Demographic data (age and gender), anthropometric data (weight, height, and body mass index), and clinical and respiratory variables (Diaphragm thickening fraction [DTf], esophageal pressure swing, respiratory rate [RR], esophageal pressure-time product per minute [PTPes/min]). RESULTS: Median DTf decreased significantly as flow increased (p < 0.05). The baseline DTf measurement was 21.4 %, 18.3 % with 20 L/m, and 16.4 % with 40 L/m. We also observed a significant decrease in RR as flow increased in HFNC (p < 0.05). In the 8 subjects with recordings, the PTPes/min was 81.3 (±30.8) cmH2O/sec/min and 64.4 (±25.3) cmH2O/sec/min at baseline and 40 L/m respectively (p = 0.044). CONCLUSIONS: The use of high-flow oxygen therapy through nasal cannula of HFNC in healthy subjects decreases the DTf and RR in association with increased flow. In addition, the use of 40 L/m flow may reduce the muscular work associated with respiration.

6.
Children (Basel) ; 11(6)2024 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-38929222

RESUMEN

In clinical practice, increased "work of breathing" (WOB) is used to rapidly identify the acutely ill child in need of immediate clinical care, and is commonly used to support a clinical diagnosis of pneumonia. However, this key clinical sign is poorly understood and inconsistently defined. This review discusses the physiology, measurement, and clinical assessment of WOB, highlighting its utility in the recognition of pneumonia in under-resourced settings, where access to diagnostic imaging may be limited.

7.
J Appl Physiol (1985) ; 137(2): 329-342, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38841757

RESUMEN

Given that there are both sex-based structural differences in the respiratory system and age-associated declines in pulmonary function, the purpose of this study was to assess the effects of age and sex on the metabolic cost of breathing (V̇o2RM) for exercise ventilations in healthy younger and older males and females. Forty healthy participants (10 young males 24 ± 3 yr; 10 young females 24 ± 3 yr; 10 older males 63 ± 3 yr, 10 older females 63 ± 6 yr) mimicked their exercise breathing patterns (voluntary hyperpnea) in the absence of exercise across a range of exercise intensities. At peak exercise, V̇o2RM represented a significantly greater fraction of peak oxygen consumption (V̇o2peak) in young females, 12.7 ± 4.0%, compared with young males, 10.7 ± 3.0% (P = 0.027), whereas V̇o2RM represented 13.5 ± 2.3% of V̇o2peak in older females and 13.2 ± 3.3% in older males. At relative ventilations, there was a main effect of age, with older males consuming a significantly greater fraction of V̇o2RM (6.6 ± 1.9%) than the younger males (4.4 ± 1.3%; P = 0.012), and older females consuming a significantly greater fraction of V̇o2RM (6.9 ± 2.5%) than the younger females (5.1 ± 1.4%; P = 0.004) at 65% V̇emax. Furthermore, both younger and older males had significantly better respiratory muscle efficiency than their female counterparts at peak exercise (P = 0.011; P = 0.015). Similarly, younger participants were significantly more efficient than older participants (6.5 ± 1.5% vs. 5.5 ± 2.0%; P = 0.001). Normal age-related changes in respiratory function, in addition to sex-based differences in airway anatomy, appear to influence the ventilatory responses and the cost incurred to breathe during exercise.NEW & NOTEWORTHY Here we show that at moderate and high-intensity exercise, older individuals incur a higher cost to breathe than their younger counterparts. However, as individuals age, the sex difference in the cost of breathing narrows. Collectively, our findings suggest that the normative age-related changes in respiratory structure and function, and sex differences in airway anatomy, appear to influence the ventilatory responses to exercise and the oxygen cost to breathe.


Asunto(s)
Ejercicio Físico , Consumo de Oxígeno , Respiración , Humanos , Masculino , Femenino , Ejercicio Físico/fisiología , Persona de Mediana Edad , Consumo de Oxígeno/fisiología , Adulto , Adulto Joven , Anciano , Envejecimiento/fisiología , Factores de Edad , Factores Sexuales , Metabolismo Energético/fisiología
8.
Ter Arkh ; 96(3): 246-252, 2024 Apr 16.
Artículo en Ruso | MEDLINE | ID: mdl-38713039

RESUMEN

AIM: To determine and compare the work of breathing to overcome elastic resistance (Ael) in patients with bronchial asthma (BA) and chronic obstructive pulmonary disease (COPD) with similar changes in the elastic properties of the parenchyma in the same settings of ventilation disorders (grade 1). MATERIALS AND METHODS: Differences in the manifestations of similar changes in the elastic properties of the lungs in patients with BA and COPD were evaluated. To identify differences, a comparative study was conducted on Аel overcome in BA patients with positive bronchodilator (with salbutamol) and bronchoconstrictor (with methacholine) tests, with reduced and preserved bronchial conductance (groups 1 and 2, respectively), and in COPD patients with negative bronchodilator and bronchoconstrictor tests (group 3). All study patients showed a grade 1 lung ventilation disorder (a decrease in the one-second forced expiratory volume by 15-35%). The results were compared with each other and with the control group (group 4, healthy non-smokers). All study patients were comparable by age and sex. The respiration mechanics was studied using simultaneous registration of spirogram and transpulmonary pressure, and the parameters of bronchial conductance and ventilation were determined using body plethysmopressography using the Jager software and hardware system. RESULTS AND CONCLUSION: In COPD patients, Ael was significantly increased (p>0.05), whereas in both BA groups, it was unchanged. Increased elastic work of breathing in patients with COPD may be associated with the involvement of certain types of contractile elements, which are preserved in patients with BA at the initial stages of the disease.


Asunto(s)
Asma , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Masculino , Femenino , Asma/fisiopatología , Persona de Mediana Edad , Trabajo Respiratorio/fisiología , Pulmón/fisiopatología , Adulto , Elasticidad , Pruebas de Función Respiratoria/métodos , Broncodilatadores/farmacología , Broncodilatadores/administración & dosificación
9.
Crit Care ; 28(1): 136, 2024 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-38654391

RESUMEN

BACKGROUND: In acute respiratory distress syndrome (ARDS), respiratory drive often differs among patients with similar clinical characteristics. Readily observable factors like acid-base state, oxygenation, mechanics, and sedation depth do not fully explain drive heterogeneity. This study evaluated the relationship of systemic inflammation and vascular permeability markers with respiratory drive and clinical outcomes in ARDS. METHODS: ARDS patients enrolled in the multicenter EPVent-2 trial with requisite data and plasma biomarkers were included. Neuromuscular blockade recipients were excluded. Respiratory drive was measured as PES0.1, the change in esophageal pressure during the first 0.1 s of inspiratory effort. Plasma angiopoietin-2, interleukin-6, and interleukin-8 were measured concomitantly, and 60-day clinical outcomes evaluated. RESULTS: 54.8% of 124 included patients had detectable respiratory drive (PES0.1 range of 0-5.1 cm H2O). Angiopoietin-2 and interleukin-8, but not interleukin-6, were associated with respiratory drive independently of acid-base, oxygenation, respiratory mechanics, and sedation depth. Sedation depth was not significantly associated with PES0.1 in an unadjusted model, or after adjusting for mechanics and chemoreceptor input. However, upon adding angiopoietin-2, interleukin-6, or interleukin-8 to models, lighter sedation was significantly associated with higher PES0.1. Risk of death was less with moderate drive (PES0.1 of 0.5-2.9 cm H2O) compared to either lower drive (hazard ratio 1.58, 95% CI 0.82-3.05) or higher drive (2.63, 95% CI 1.21-5.70) (p = 0.049). CONCLUSIONS: Among patients with ARDS, systemic inflammatory and vascular permeability markers were independently associated with higher respiratory drive. The heterogeneous response of respiratory drive to varying sedation depth may be explained in part by differences in inflammation and vascular permeability.


Asunto(s)
Biomarcadores , Permeabilidad Capilar , Inflamación , Síndrome de Dificultad Respiratoria , Humanos , Síndrome de Dificultad Respiratoria/fisiopatología , Síndrome de Dificultad Respiratoria/sangre , Masculino , Femenino , Persona de Mediana Edad , Permeabilidad Capilar/fisiología , Permeabilidad Capilar/efectos de los fármacos , Inflamación/fisiopatología , Inflamación/sangre , Anciano , Biomarcadores/sangre , Biomarcadores/análisis , Angiopoyetina 2/sangre , Angiopoyetina 2/análisis , Interleucina-8/sangre , Interleucina-8/análisis , Interleucina-6/sangre , Interleucina-6/análisis , Mecánica Respiratoria/fisiología
11.
Pediatr Pulmonol ; 59(5): 1274-1280, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38353341

RESUMEN

PURPOSE: We aimed to assess diaphragmatic function in term and preterm infants with and without history of bronchopulmonary dysplasia (BPD), before and after the application of inspiratory flow resistive loading. METHODS: Forty infants of a median (range) gestational age of 34 (25-40) weeks were studied. BPD was defined as supplemental oxygen requirement for >28 days of life. Seventeen infants were term, 17 preterm without history of BPD, and six preterm with a history of BPD. The diaphragmatic pressure-time index (PTIdi) was calculated as the mean to maximum trans-diaphragmatic pressure ratio times the inspiratory duty cycle. The PTIdi was calculated before and after the application of an inspiratory-flow resistance for 120 s. Airflow was measured by a pneumotachograph and the transdiaphragmatic pressure by a dual pressure catheter. RESULTS: The median (interquartile range [IQR]) pre-resistance PTIdi was higher in preterm infants without BPD (0.064 [0.050-0.077]) compared with term infants (0.052 [0.044-0.062], p = .029) and was higher in preterm infants with BPD (0.119 [0.086-0.132]) compared with a subgroup of preterm infants without BPD (0.062 [0.056-0.072], p = .004). The median (IQR) postresistance PTIdi was higher in preterm infants without BPD (0.101 [0.084-0.132]) compared with term infants (0.067 [0.055-0.083], p < .001) and was higher in preterm infants with BPD [0.201(0.172-0.272)] compared with the preterm subgroup without BPD (0.091 [0.081-0.108],p = .004). The median (IQR) percentage change of the PTIdi after the application of the resistance was higher in preterm infants without BPD (65 [51-92] %) compared with term infants (34 [20-39] %, p < .001). CONCLUSIONS: Preterm infants, especially those recovering from BPD, are at increased risk of diaphragmatic muscle fatigue under conditions of increased inspiratory loading.


Asunto(s)
Displasia Broncopulmonar , Diafragma , Recien Nacido Prematuro , Humanos , Diafragma/fisiopatología , Recién Nacido , Masculino , Displasia Broncopulmonar/fisiopatología , Femenino , Edad Gestacional , Inhalación/fisiología
12.
Crit Care ; 27(1): 466, 2023 11 29.
Artículo en Inglés | MEDLINE | ID: mdl-38031116

RESUMEN

BACKGROUND: Monitoring respiratory effort in ventilated patients is important to balance lung and diaphragm protection. Esophageal manometry remains the gold standard for monitoring respiratory effort but is invasive and requires expertise for its measurement and interpretation. Airway pressures during occlusion maneuvers may provide an alternative, although pediatric data are limited. We sought to determine the correlation between change in esophageal pressure during tidal breathing (∆Pes) and airway pressure measured during three airway occlusion maneuvers: (1) expiratory occlusion pressure (Pocc), (2) airway occlusion pressure (P0.1), and (3) respiratory muscle pressure index (PMI) in children. We also sought to explore pediatric threshold values for these pressures to detect excessive or insufficient respiratory effort. METHODS: Secondary analysis of physiologic data from children between 1 month and 18 years of age with acute respiratory distress syndrome enrolled in an ongoing randomized clinical trial testing a lung and diaphragm protective ventilation strategy (REDvent, R01HL124666). ∆Pes, Pocc, P0.1, and PMI were measured. Repeated measure correlations were used to investigate correlation coefficients between ∆Pes and the three measures, and linear regression equations were generated to identify potential therapeutic thresholds. RESULTS: There were 653 inspiratory and 713 expiratory holds from 97 patients. Pocc had the strongest correlation with ∆Pes (r = 0.68), followed by PMI (r = 0.60) and P0.1 (r = 0.42). ∆Pes could be reliably estimated using the regression equation ∆Pes = 0.66 [Formula: see text] Pocc (R2 = 0.82), with Pocc cut-points having high specificity and moderate sensitivity to detect respective ∆Pes thresholds for high and low respiratory effort. There were minimal differences in the relationship between Pocc and ∆Pes based on age (infant, child, adolescent) or mode of ventilation (SIMV versus Pressure Support), although these differences were more apparent with P0.1 and PMI. CONCLUSIONS: Airway occlusion maneuvers may be appropriate alternatives to esophageal pressure measurement to estimate the inspiratory effort in children, and Pocc represents the most promising target. TRIAL REGISTRATION: NCT03266016; August 23, 2017.


Asunto(s)
Diafragma , Respiración , Lactante , Adolescente , Humanos , Niño , Pulmón , Respiración con Presión Positiva , Respiración Artificial
13.
Ann Intensive Care ; 13(1): 104, 2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37851284

RESUMEN

BACKGROUND: Prophylactic high-flow nasal cannula (HFNC) oxygen therapy can decrease the risk of extubation failure. It is frequently used in the postextubation phase alone or in combination with noninvasive ventilation. However, its physiological effects in this setting have not been thoroughly investigated. The aim of this study was to determine comprehensively the effects of HFNC applied after extubation on respiratory effort, diaphragm activity, gas exchange, ventilation distribution, and cardiovascular biomarkers. METHODS: This was a prospective randomized crossover physiological study in critically ill patients comparing 1 h of HFNC versus 1 h of standard oxygen after extubation. The main inclusion criteria were mechanical ventilation for at least 48 h due to acute respiratory failure, and extubation after a successful spontaneous breathing trial (SBT). We measured respiratory effort through esophageal/transdiaphragmatic pressures, and diaphragm electrical activity (ΔEAdi). Lung volumes and ventilation distribution were estimated by electrical impedance tomography. Arterial and central venous blood gases were analyzed, as well as cardiac stress biomarkers. RESULTS: We enrolled 22 patients (age 59 ± 17 years; 9 women) who had been intubated for 8 ± 6 days before extubation. Respiratory effort was significantly lower with HFNC than with standard oxygen therapy, as evidenced by esophageal pressure swings (5.3 [4.2-7.1] vs. 7.2 [5.6-10.3] cmH2O; p < 0.001), pressure-time product (85 [67-140] vs. 156 [114-238] cmH2O*s/min; p < 0.001) and ΔEAdi (10 [7-13] vs. 14 [9-16] µV; p = 0.022). In addition, HFNC induced increases in end-expiratory lung volume and PaO2/FiO2 ratio, decreases in respiratory rate and ventilatory ratio, while no changes were observed in systemic hemodynamics, Troponin T, or in amino-terminal pro-B-type natriuretic peptide. CONCLUSIONS: Prophylactic application of HFNC after extubation provides substantial respiratory support and unloads respiratory muscles. Trial registration January 15, 2021. NCT04711759.

14.
J Physiol ; 601(21): 4807-4821, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37772933

RESUMEN

Intrathoracic pressure (ITP) swings that permit spontaneous ventilation have physiological implications for the heart. We sought to determine the effect of respiration on cardiac output ( Q ̇ $\dot Q$ ) during semi-supine cycle exercise using a proportional assist ventilator to minimize ITP changes and lower the work of breathing (Wb ). Twenty-four participants (12 females) completed three exercise trials at 30%, 60% and 80% peak power (Wmax ) with unloaded (using a proportional assist ventilator, PAV) and spontaneous breathing. Intrathoracic and intraabdominal pressures were measured with balloon catheters placed in the oesophagus and stomach. Left ventricular (LV) volumes and Q ̇ $\dot Q$ were determined via echocardiography. Heart rate (HR) was measured with electrocardiogram and a customized metabolic cart measured oxygen uptake ( V ̇ O 2 ${\dot V_{{{\mathrm{O}}_{\mathrm{2}}}}}$ ). Oesophageal pressure swings decreased from spontaneous to PAV breathing by -2.8 ± 3.1, -4.9 ± 5.7 and -8.1 ± 7.7 cmH2 O at 30%, 60% and 80% Wmax , respectively (P = 0.01). However, the decreases in Wb were similar across exercise intensities (27 ± 42 vs. 35 ± 24 vs. 41 ± 22%, respectively, P = 0.156). During PAV breathing compared to spontaneous breathing, Q ̇ $\dot Q$ decreased by -1.0 ± 1.3 vs. -1.4 ± 1.4 vs. -1.5 ± 1.9 l min-1 (all P < 0.05) and stroke volume decreased during PAV breathing by -11 ± 12 vs. -9 ± 10 vs. -7 ± 11 ml from spontaneous breathing at 30%, 60% and 80% Wmax , respectively (all P < 0.05). HR was lower during PAV breathing by -5 ± 4 beats min-1 at 80% Wmax (P < 0.0001). Oxygen uptake decreased by 100 ml min-1 during PAV breathing compared to spontaneous breathing at 80% Wmax (P < 0.0001). Overall, attenuating ITPs mitigated LV preload and ejection, thereby suggesting that the ITPs associated with spontaneous respiration impact cardiac function during exercise. KEY POINTS: Pulmonary ventilation is accomplished by alterations in intrathoracic pressure (ITP), which have physiological implications on the heart and dynamically influence the loading parameters of the heart. Proportional assist ventilation was used to attenuate ITP changes and decrease the work of breathing during exercise to examine its effects on left ventricular (LV) function. Proportional assist ventilation with progressive exercise intensities (30%, 60% and 80% Wmax ) led to reductions in cardiac output at all intensities, primarily through reductions in stroke volume. Decreases in LV end-diastolic volume (30% and 60% Wmax ) and increases in LV end-systolic volume (80% Wmax ) were responsible for the reduction in stroke volume. The relationship between cardiac output and oxygen uptake is disrupted during respiratory muscle unloading.


Asunto(s)
Corazón , Respiración , Femenino , Humanos , Volumen Sistólico , Función Ventricular Izquierda , Oxígeno , Gasto Cardíaco
15.
Br J Nurs ; 32(13): 613-619, 2023 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-37410687

RESUMEN

Respiratory disease is ubiquitous in hospitals and community healthcare settings in the UK. Nurses, therefore, must be able to understand the physiology and pathophysiology that underpins the care they provide for people living with a respiratory disorder. This article summarises the fundamental anatomy and physiology of the respiratory system and respiration. It also explores the pathophysiological changes that occur in the four most common respiratory conditions, namely pneumonia, lung cancer, asthma and chronic obstructive pulmonary disease. Key elements of a comprehensive respiratory assessment and how nurses can determine acute deterioration are explored. The case study and reflective questions aim to enhance the reader's understanding of respiratory assessment and nursing care.


Asunto(s)
Asma , Neumonía , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Pulmón , Respiración
16.
Respir Care ; 68(10): 1393-1399, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37221083

RESUMEN

BACKGROUND: Most ventilators measure airway occlusion pressure (occlusion P0.1) by occluding the breathing circuit; however, some ventilators can predict P0.1 for each breath without occlusion. Nevertheless, few studies have verified the accuracy of continuous P0.1 measurement. The aim of this study was to evaluate the accuracy of continuous P0.1 measurement compared with that of occlusion methods for various ventilators using a lung simulator. METHODS: A total of 42 breathing patterns were validated using a lung simulator in combination with 7 different inspiratory muscular pressures and 3 different rise rates to simulate normal and obstructed lungs. PB980 and Dräger V500 ventilators were used to obtain occlusion P0.1 measurements. The occlusion maneuver was performed on the ventilator, and a corresponding reference P0.1 was recorded from the ASL5000 breathing simulator simultaneously. Hamilton-C6, Hamilton-G5, and Servo-U ventilators were used to obtain sustained P0.1 measurements (continuous P0.1). The reference P0.1 measured with the simulator was analyzed by using a Bland-Altman plot. RESULTS: The 2 lung mechanical models capable of measuring occlusion P0.1 yielded values equivalent to reference P0.1 (bias and precision values were 0.51 and 1.06, respectively, for the Dräger V500, and were 0.54 and 0.91, respectively, for the PB980). Continuous P0.1 for the Hamilton-C6 was underestimated in both the normal and obstructive models (bias and precision values were -2.13 and 1.91, respectively), whereas continuous P0.1 for the Servo-U was underestimated only in the obstructive model (bias and precision values were -0.86 and 1.76, respectively). Continuous P0.1 for the Hamilton-G5 was mostly similar to but less accurate than occlusion P0.1 (bias and precision values were 1.62 and 2.06, respectively). CONCLUSIONS: The accuracy of continuous P0.1 measurements varies based on the characteristics of the ventilator and should be interpreted by considering the characteristics of each system. Moreover, measurements obtained with an occluded circuit could be desirable for determining the true P0.1.


Asunto(s)
Respiración Artificial , Ventiladores Mecánicos , Humanos , Pulmón , Simulación por Computador , Diseño de Equipo
17.
Respir Physiol Neurobiol ; 313: 104070, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37141930

RESUMEN

This study compared work of breathing (WOB) and the pressure time product (PTP) to verify whether WOB and PTP decrease in the forward-leaning posture compared with erect sitting. Seven healthy adults (two females and five males) adopted three sitting postures: upright, and two forward-leaning postures of 15° and 30°. The WOB was obtained using the modified Campbell diagram, and PTP was calculated as the time integral of the area between esophageal and chest wall pressure. End-expiratory lung volume and transpulmonary pressure were significantly increased in the 15° and 30° forward-leaning postures compared with erect sitting (p â‰¦ 0.05). End-inspiratory lung volume was significantly increased in the 30° forward-leaning posture compared to erect sitting (p â‰¦ 0.05). PTP and inspiratory resistive WOB were significantly lower in the 15° and 30° forward-leaning postures compared to erect sitting (p â‰¦ 0.05). Forward leaning increases lung volume, which may dilate the airways, decrease resistant WOB, and reduce respiratory muscle activity.


Asunto(s)
Respiración , Trabajo Respiratorio , Masculino , Adulto , Femenino , Humanos , Trabajo Respiratorio/fisiología , Mediciones del Volumen Pulmonar , Postura/fisiología , Extremidad Superior
18.
Respir Care ; 68(6): 767-772, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37225650

RESUMEN

BACKGROUND: Analysis of observational data suggests that both a T-piece and zero pressure support ventilation (PSV) and zero PEEP impose work of breathing (WOB) during a spontaneous breathing trial (SBT) similar to what a patient experiences after extubation. The aim of our study was to compare the WOB imposed by the T-piece with zero PSV and zero PEEP. We also compared the difference in WOB when using zero PSV and zero PEEP on 3 different ventilators. METHODS: This study was conducted by using a breathing simulator that simulated 3 lung models (ie, normal, moderate ARDS, and COPD). Three ventilators were used and set to zero PSV and zero PEEP. The outcome variable was WOB expressed as mJ/L of tidal volume. RESULTS: An analysis of variance showed that WOB was statistically different between the T-piece and zero PSV and zero PEEP on all the ventilators (Servo-i, Servo-u, and Carescape R860). The absolute difference was lowest for the Carescape R860, which increased WOB by 5-6%, whereas the highest for Servo-u, which reduced the WOB by 15-21%. CONCLUSIONS: Work may be imposed or reduced during spontaneous breathing on zero PSV and zero PEEP when compared to T-piece. The unpredictable nature of how zero PSV and zero PEEP behaves on different ventilators makes it an imprecise SBT modality in the context of assessing extubation readiness.


Asunto(s)
Respiración , Trabajo Respiratorio , Humanos , Ventiladores Mecánicos , Extubación Traqueal , Modalidades de Fisioterapia
19.
Respir Care ; 68(6): 760-766, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37225654

RESUMEN

BACKGROUND: The spontaneous breathing trial (SBT) is the final step of weaning from invasive mechanical ventilation. An SBT is aimed at predicting work of breathing (WOB) after extubation and, most importantly, a patient's eligibility for extubation. The optimal SBT modality remains debated. A high-flow oxygen (HFO) has been tested during SBT in clinical study only, which is why no definite conclusion can be drawn on its physiologic effects on the endotracheal tube. Our objective was to assess, on a bench, inspiratory tidal volume (VT), total PEEP, and WOB across 3 different SBT modalities: T-piece, 40 L/min HFO, and 60 L/min HFO. METHODS: A test lung model was set with 3 conditions of resistance and linear compliance, 3 inspiratory efforts (low, normal, and high), each at 2 breathing frequencies (low and high for 20 and 30 breaths/min, respectively). Pairwise comparisons and a quasi-Poisson generalized linear model that compared SBT modalities were performed. RESULTS: Inspiratory VT, total PEEP, and WOB differed from one SBT modality to another. Inspiratory VT remained higher with the T-piece than in the HFO independent of the mechanical condition, effort intensity, and breathing frequency (P < .001 in each comparison). WOB adjusted by the inspiratory VT was significantly lower during SBT performed with an HFO than when performed with the T-piece (P < .001 in each comparison). The total PEEP was significantly higher in the HFO at 60 L/min than in the other modalities (P < .001). The end points were significantly influenced by breathing frequency, effort intensity, and mechanical condition. CONCLUSIONS: With the same effort intensity and breathing frequency, inspiratory VT was higher in the T-piece than in the other modalities. Compared with the T-piece, WOB was significantly lower in the HFO condition and higher flow was a benefit. Based on the results of the present study, the HFO as an SBT modality would seem to require clinical testing.


Asunto(s)
Extubación Traqueal , Respiración Artificial , Humanos , Modelos Lineales , Oxígeno , Cooperación del Paciente
20.
J Pers Med ; 13(4)2023 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-37108979

RESUMEN

Patient self-inflicted lung injury (P-SILI) is a life-threatening condition arising from excessive respiratory effort and work of breathing in patients with lung injury. The pathophysiology of P-SILI involves factors related to the underlying lung pathology and vigorous respiratory effort. P-SILI might develop both during spontaneous breathing and mechanical ventilation with preserved spontaneous respiratory activity. In spontaneously breathing patients, clinical signs of increased work of breathing and scales developed for early detection of potentially harmful effort might help clinicians prevent unnecessary intubation, while, on the contrary, identifying patients who would benefit from early intubation. In mechanically ventilated patients, several simple non-invasive methods for assessing the inspiratory effort exerted by the respiratory muscles were correlated with respiratory muscle pressure. In patients with signs of injurious respiratory effort, therapy aimed to minimize this problem has been demonstrated to prevent aggravation of lung injury and, therefore, improve the outcome of such patients. In this narrative review, we accumulated the current information on pathophysiology and early detection of vigorous respiratory effort. In addition, we proposed a simple algorithm for prevention and treatment of P-SILI that is easily applicable in clinical practice.