Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 204
Filtrar
1.
Cureus ; 16(8): e66054, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39224719

RESUMEN

Introduction Canal preparation is a critical step in endodontic therapy. Introducing nickel-titanium (NiTi) rotary instruments has significantly reduced the likelihood of errors in curved canals. However, due to their price, these instruments are often reused following autoclaving. The aim of this study is to compare and evaluate the surface characteristics of two designs of rotary NiTi files used in curved canals and subjected to multiple autoclaving cycles, utilizing an atomic force microscope for detailed analysis. Methods A total sample size of 24 files was taken, 12 files of Hyflex EDM (Coltene/Whaledent, Germany) files and WaveOne Gold (Dentsply Sirona, USA) files were then divided into four groups (n=6) as follows: Group I: Hyflex EDM control group; Group II: WaveOne Gold control group; Group III: Hyflex EDM experimental group; Group IV: WaveOne Gold experimental group. Sterilization using an autoclave was performed thrice for Groups I and II files. The files in Groups III and IV were used in simulated curved canals three times and autoclaved after each use. Atomic force microscopy was used to assess the surface roughness of the files after the first and third autoclave cycles. Results The results showed that, without statistical significance, Hyflex EDM exhibited the highest surface roughness after the first usage among the two file systems. Conclusion It can be concluded that both Hyflex EDM and WaveOne Gold files produced similar levels of surface changes when subjected to multiple usage and autoclaving cycles.

2.
Materials (Basel) ; 17(16)2024 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-39203156

RESUMEN

This study assessed the surface topography and plastic deformation (PD) of new and used contemporary reciprocating instruments. Twenty-six WaveOne Gold (WOG) and EdgeOne Fire (EO) instruments were photographed under magnification. The instruments were randomly assigned to a control group of new instruments preserved for surface roughness analysis (n = 6 each), or to an experimental group to shape the root canal system of a single molar (n = 20 each), making a total of four groups (WOGnew, EOnew, WOGused, EOused). Used instruments were also photographed after instrumentation. The presence of fractures was registered. Preoperative and postoperative images were randomly ordered for evaluation. Two blinded calibrated examiners evaluated the presence of PD. Inter-observer agreement was calculated with the Kappa coefficient (K = 0.89). 3D profilometry was also used for the surface roughness analysis of six randomly selected instruments from the WOGused and EOused groups. Chi-square and two-way ANOVA tests were used to, respectively, compare PD and changes in surface roughness among the groups. No instruments fractured; however, a significantly greater percentage of EO instruments suffered plastic deformation than WOG instruments (p < 0.001), (OR = 11.09 (CI 95% 2.6-56.3)). The overall surface roughness was higher for most parameters in the EO instruments (p < 0.05). Single uses of EO instruments produced significantly higher chances of PD and increased surface roughness values compared to WOG.

3.
Dent J (Basel) ; 12(6)2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38920883

RESUMEN

OBJECTIVES: The article's aim is to test if rotary or reciprocating glide path influences the overall performance of WaveOne Gold in S-shaped canals. METHODS: Sixty endo training blocks with an S-shape curvature were divided into three groups based on the glide path method used: no glide path; glide path preparation with ProGlider; glide path preparation with WaveOne Gold Glider. All blocks were then shaped with WaveOne Gold Primary. The time for shaping, the incidence in reaching working length and the number of pecking motions were recorded. ANOVA with Turkey's test was used, and the p-value was set to 0.05. RESULTS: WaveOne Gold Primary reached working length faster in the control group when comparing total working times. No significant differences in the ability of the WaveOne Gold Primary to reach working length in all groups (p > 0.05). The mean number of pecking motions was higher in the control group compared to other groups. CONCLUSIONS: No significant differences in the time needed to achieve a glide path between Proglider and WaveOne Gold Glider. WaveOne Gold Primary can shape a double curved canal faster if a glide path is present but takes less time to reach length if it is the only file used. No difference in the ability to reach working length.

4.
Microsc Res Tech ; 87(10): 2399-2407, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38813968

RESUMEN

This study aims to compare the shaping ability of three systems using micro-computed tomography (micro-CT). Moderately-curved mesial canals of 36 mandibular molars were assigned to three groups (n = 24); Protaper Next (PTN, 0.25, 0.06), WaveOne Gold (WOG, 0.25, 0.07), TruNatomy (TRN, 0.25, 0.04), and instrumentation was performed. Pre- and post-micro-CT scans were obtained. Canal volume and surface, structure model index (SMI), centroid shift, canal transportation, and untouched canal were analyzed. One-way ANOVA and Student's t-test were used for statistics. There was no difference in SMI, centroid shift, and centering ability between the study groups (p > .05). Removed dentin and canal surface changes were lower in TRN, while untouched dentin walls were higher (p < .05). Cross-sections became more rounded (p < .05), but not significant between groups (p > .05). Considering the removed dentin by TRN, it can be used in critical dentin thickness, such as the danger zone (DZ). PTN, WOG, and WOG kept the original canal course similarly. Untouched dentin by TRN (41%) was wider than PTN and WOG, consequently, meticulous irrigation is recommended. TRN, which provides a controlled increase in canal volume, can be used in thin dentin such as the DZ, however, its use should be supported by copious irrigation and brushing considering the rate of untouched dentin walls. RESEARCH HIGHLIGHTS: TRN presented a higher untouched dentin wall compared to PTN and WOG. Canal volume and surface changes were the lowest in the TRN group. The centering abilities were similar in PTN, WOG, and TRN.


Asunto(s)
Cavidad Pulpar , Diente Molar , Preparación del Conducto Radicular , Microtomografía por Rayos X , Microtomografía por Rayos X/métodos , Humanos , Diente Molar/anatomía & histología , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Cavidad Pulpar/anatomía & histología , Cavidad Pulpar/diagnóstico por imagen , Dentina , Mandíbula/anatomía & histología , Mandíbula/diagnóstico por imagen
5.
Aust Endod J ; 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38773855

RESUMEN

To use scanning electron microscopy and energy dispersive X-ray spectroscopy to evaluate the metallurgical-chemical changes of WaveOne Gold (WOG) and R-Motion (RM), after multiple uses. The instruments were divided into groups (n = 8): WOG and RM-control groups, new instruments; WOG1 and RM1; WOG2 and RM2; WOG3 and RM3 after instrumentation of 1, 2 or 3 molars, respectively. Burrs occurred mainly in the control group and after the first use. The RM files were found to have a higher nickel content, which increased during reuse, and a decrease in oxygen content with increasing reuse, in addition to calcium impregnation, which occurred in greater amounts in the corrosion areas in the WOG files. The presence of topographic and chemical changes was demonstrated, indicating that caution should be taken when reusing endodontic instruments to avoid fractures.

6.
J Pharm Bioallied Sci ; 16(Suppl 1): S327-S328, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38595460

RESUMEN

Objectives: The study's objective was to contrast the two distinct rotary file techniques used to shape mandibular first molars. Materials and Methods: The investigation involved twenty recently removed mandibular molars. A digital single-lens reflex (DSLR) camera was placed in a fixed position, a muffle block was built, and images of each tooth's three cross sections were obtained. The specimens were split into the following two groups at random: Rotary files from WaveOne were used to prepare group A and Mtwo rotary files were used to prepare group B. Results: At the coronal, middle, and apical thirds of the root canals, WaveOne file system demonstrated improved centering ability compared with the Mtwo file system (P 0.05). Conclusion: When compared to the Mtwo file system, WaveOne file system demonstrated improved centering capabilities and needed significantly less time to build the curved canals.

7.
J Pharm Bioallied Sci ; 16(Suppl 1): S780-S782, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38595610

RESUMEN

Background: An important aspect of the preparation of the access cavity and biomechanical preparation of the root canal is to safeguard as much of the tooth's framework as possible without affecting access and visibility. Objectives: To compare the impact of the conservative design of access preparation and traditional design of access preparation in association with TruNatomy endodontic instrumentation and WaveOne Gold endodontic instrumentation on resistance to fracture by the design of a cavity for endodontic access using finite element analysis. Materials and Methods: Micro-CT radiographic images of 16 human first permanent molars of the mandible were included in the study to create representative finite element analysis computational models. Results: A significant reduction in load for failure after endodontic preparation was observed in TDAP subcategories as compared to specimens with CDAP. However, the reduction in load for failure was comparable in both endodontic instrument systems within the CDAP and TDAP. Conclusion: A significant reduction in load for failure after endodontic preparation was observed in the traditional design of access preparation subcategories as compared to specimens with the conventional design of access preparation.

8.
J Endod ; 50(2): 120-128, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37924939

RESUMEN

INTRODUCTION: This study aimed to evaluate postoperative pain intensity following glide-path preparation using the ProGlider (PG) and WaveOne Gold Glider (WOGG) systems in asymptomatic teeth with necrotic pulp and periapical lesions. METHODS: In this randomized clinical trial (ClinicalTrials.gov ID: NCT05955742) maxillary and mandibular molars with asymptomatic apical periodontitis of 78 patients (age, 18-65 years) were included. The patients were randomly divided into 3 groups: control (n = 26), PG (n = 26), and WOGG (n = 26). All the systems were used according to the manufacturer's instructions, and all the root canal treatments were completed by a single operator within 2 sessions. Postoperative pain was assessed using a numerical rating scale at 6, 12, 18, 24, 48, and 72 hours. Analgesics administered and abscess formation were also recorded. Statistical analyses were performed using the Mann-Whitney U, Bonferroni Dunn, Friedman, Chi-square, and Fisher exact tests. RESULTS: The postoperative pain at 12 and 18 hours was lower in the WOGG group than in the other groups (P < .05). The postoperative pain scores at 6 and 24 hours were higher among women than among men (P < .05). The highest postoperative pain scores were observed at 6 hours (P < .05). CONCLUSIONS: The WOGG glide-path file system was associated with less postoperative pain than the other systems. Abscess formation and analgesic use were higher in the PG group than in the other groups. Postoperative pain was greater in women than in men.


Asunto(s)
Absceso , Preparación del Conducto Radicular , Humanos , Femenino , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Masculino , Preparación del Conducto Radicular/efectos adversos , Dolor Postoperatorio/etiología , Diente Molar/cirugía , Tratamiento del Conducto Radicular/efectos adversos , Oro , Cavidad Pulpar/cirugía
9.
BMC Oral Health ; 23(1): 780, 2023 10 24.
Artículo en Inglés | MEDLINE | ID: mdl-37875946

RESUMEN

BACKGROUND: This study aimed to compare the shaping ability of different instruments, TruNatomy Glider (TRN-G), WaveOne Gold Glider (WOG-G), and ProGlider (Pro-G) using micro-computed tomography (micro-CT). METHODS: The mesial canals of 27 mandibular molars with two separate mesial canals and moderate curvature were included in this study [n = 27 mesiobuccal (MB) and mesiolingual (ML) root canal]. According to the manufacturer's instructions, the glide path was created with TRN-G, WOG-G, and Pro-G glide path instruments (n = 9 MB and ML root canal in each group). Micro-CT scanning was performed before and after preparation. Mesiodistal (MD) and buccolingual (BL) transportation and the centering ratio were measured at three levels within the canal (3, 5 and 7 mm). A three-way robust ANOVA was used to compare the parameters. RESULTS: TRN-G showed significantly greater transportation in the MD direction than the other instruments throughout the root canal (overall root canal) (p < 0.05). The best centering ability in the BL direction was shown by the WOG-G, regardless of level within the canal and canal distinction (MB vs. ML) (p < 0.05). There was no significant difference between groups according to the level within the canal and canal parameters (p > 0.05). Whether the root canal was MB or ML did not affect centering or transportation (p > 0.05). CONCLUSIONS: Glide path instruments can be used to shape moderately curved canals with minimal apical transportation and better centering ability. All three tested glide path files can used safely before the shaping file.


Asunto(s)
Preparación del Conducto Radicular , Raíz del Diente , Humanos , Microtomografía por Rayos X/métodos , Tratamiento del Conducto Radicular , Cavidad Pulpar/diagnóstico por imagen , Diseño de Equipo
10.
J Endod ; 49(12): 1733-1738, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37717909

RESUMEN

INTRODUCTION: Innovative file systems have been recently introduced, claiming improved effectiveness and superior ability to preserve the tooth structure, still allowing an efficient preparation and disinfection up to the apical region. Regardless, few data are available on the comparative effectiveness of the most recently developed systems. Thus, this ex vivo study aimed to comparatively evaluate, for the first time, the functionality of WaveOne Gold (WOG), TruNatomy (TN), and ProTaper Ultimate (PU) file systems regarding canal shaping, dentin preservation, and smear layer removal ability. METHODS: Human maxillary incisors were randomly divided for instrumentation with one of the assayed systems. Canal shaping ability and pericervical dentin preservation were characterized through microtomographic evaluation and morphometric assessment (n = 15). Smear layer removal ability was evaluated by scanning electron microscopy (SEM) (n = 6). RESULTS: TN and PU presented the lowest canal volume variation upon instrumentation, found to be significantly lower than that attained with WOG (P < .05). Pericervical dentin was reduced in all groups upon instrumentation, with TN evidencing the highest preservation, quantitatively similar to PU, and significantly higher than that attained with WOG (P < .05). SEM imaging revealed the presence of scattered remnants of the smear layer and partially opened dentinal tubules at the apical portion, with no significant differences between systems. CONCLUSIONS: TN and PU allowed for the highest tissue preservation, reporting the lowest volume variation and the highest preservation of the pericervical dentin. None of the assessed systems provided a complete removal of the smear layer in the apical region.


Asunto(s)
Capa de Barro Dentinario , Humanos , Dentina , Cavidad Pulpar/diagnóstico por imagen , Oro , Preparación del Conducto Radicular , Irrigantes del Conducto Radicular
11.
Cureus ; 15(7): e42290, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37609092

RESUMEN

BACKGROUND: Preventing the apical extrusion of debris during instrumentation is of paramount importance to reduce the occurrence of flare-ups in endodontically treated teeth. Furthermore, an essential requirement for the longevity and strength of an endodontically treated tooth and its ability to resist fracture is the preservation of residual dentin thickness during instrumentation. The aim of this study was to compare the amount of debris extrusion, remaining dentin thickness at the coronal third, middle third, apical third, and the fracture resistance of the teeth using rotary (TruNatomy; Dentsply Sirona, Charlotte, NC) and reciprocating (WaveOne Gold; Dentsply Sirona) endodontic file systems. METHODS: An in vitro study included 52 single-rooted, oval canal shaped teeth that underwent exploration and initial cleaning with a no. 15 K-file. The prepared canals were then randomly assigned to two groups: Group I, with instrumentation with the TruNatomy rotary file (n=26) and Group II, with instrumentation with the WaveOne Gold reciprocating file. Parameters like debris extrusion, remaining dentin thickness, and fracture resistance were evaluated in both the groups. Analysis was performed using a paired t-test for the assessment of difference between groups and one-way ANOVA test followed by the post-hoc Tukey test for difference between the coronal, middle and apical third for each study group. RESULTS: The results revealed no significant difference (t=0.454, p=0.652) between the TruNatomy rotary file and WaveOne Gold reciprocating file in apical extrusion of debris after their use in root canal therapy. For the remaining dentin thickness, a significant difference was present between the TruNatomy rotary file and WaveOne Gold reciprocating rotary file at the coronal (t=5.766, p<0.0001) and middle (t=3.690, p=0.001) levels. The mean fracture resistance was significantly more (t=15.877, p<0.0001) with the TruNatomy rotary file compared to the WaveOne Gold reciprocating rotary file. CONCLUSION: The TruNatomy rotary file system outperformed the WaveOne Gold reciprocating file system in terms of maintaining the remaining dentin thickness and providing improved fracture resistance. Nevertheless, debris extruded apically was comparable between the TruNatomy rotary file system and the WaveOne Gold reciprocating file system.

12.
Odovtos (En línea) ; 25(2)ago. 2023.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1448744

RESUMEN

To evaluate whether the WaveOne Gold and Reciproc single file instrumentation systems, are effective in reducing the microbial load of a mixed biofilm and the cleaning of apical third compared to the Twisted File Adaptive system (multiple- file system). Seventy mesial roots of the first and second molars were included and randomly divided into three experimental groups (n=20, n=10 controls). Biofilms were formed inside canals over 31 days. After instrumentation with the unique file systems, WaveOne Gold and Reciproc and the multiple file system Twisted File Adaptive, using 2.25% sodium hypochlorite as an irrigant in all cases, a count of colony forming units was performed using serial dilutions, cleaning of the apical third was evaluated using scanning electron microscopy. Comparisons amongst groups were made by using parametric and non-parametric statistics, according to a normal or non-normal data distribution, respectively. No significant differences in the reduction of the microbial load after employing a single-file system in comparison to the multiple-file system were found; in addition, the cleaning of the apical third was similar for the three different instrumentation systems. The single-file system is equal in effectiveness compared with the multiple-file system in reducing the microbial load.


Evaluar si los sistemas de instrumentación de lima única, como WaveOne Gold y Reciproc son efectivos para reducir la carga microbiana de un biofilm mixto y la limpieza del tercio apical, comparado con los sistemas de limas múltiples, como Twisted File Adaptive. Setenta raíces mesiales de primeros y segundos molares fueron incluidos y divididos de forma aleatoria en tres grupos experimentales (n=20, n=10 controles). El biofilm fue formado en el interior de los conductos durante 31 días. Después se instrumentó con los sistemas de lima única (WaveOne Gold y Reciproc) y el sistema de limas múltiples Twisted File Adaptive, usando hipoclorito de sodio al 2.5% en todos los casos. El conteo de unidades formadoras de colonias se realizó usando diluciones seriales, la limpieza del tercio apical se evaluó empleando el microscopio electrónico de barrido. La comparación entre grupos se realizó con pruebas paramétricas y no paramétricas, de acuerdo con la distribución normal y no normal de los datos, respectivamente. No hubo una diferencia significativa en la reducción de la carga microbiana después de emplear los sistemas de lima única en comparación a los de limas múltiples, además, la limpieza del tercio apical fue similar en los 3 diferentes sistemas de instrumentación. Los sistemas de lima única son igual de efectivos para reducir la carga microbiana comparados con los sistemas de limas múltiples.

13.
Cureus ; 15(5): e38829, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37303406

RESUMEN

AIM: This study set out to compare the damage done to dentin by three distinct titanium file brands - the Hyflex EDM, the ProTaper Next, and the Waveone Gold Nickel - in order to draw conclusions about which one is the most effective. MATERIALS AND METHODS: Forty-first premolars in the mandible with straight canals and single roots were instrumented using Hyflex EDM, Waveone Gold, and Protaper Next. Dentinal flaws after endodontic treatment were studied by sectioning specimens using a hard tissue microtome and analyzing them under a stereomicroscope. RESULTS: There was no discernible variation between the groups in the coronal third (p=0.312) or apical third (p=0.076). Hyflex EDM and Protaper Next differed significantly in the middle portion of the tape (p=0.016). The Hyflex EDM sample had the fewest cracks. There was no statistically significant difference between Hyflex EDM and Waveone Gold; however, Hyflex EDM had fewer fractures in the middle third of the sample than Waveone Gold did. CONCLUSION: Electric discharge machining (EDM) files made from Hyflex proved to be far superior to their Protaper Next and Waveone Gold counterparts as they induced the fewest cracks in the middle third of the root dentin.

14.
Cureus ; 15(4): e37503, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37187639

RESUMEN

Background: In endodontics, the three processes of biomechanical preparation, disinfection, and obturation are each essential. The electron microprobe and scanning electron microscope (SEM) allowed for the detection and identification of the smear layer and debris. The purpose of the current investigation was to use a scanning electron microscope to evaluate the relative merits of two single-file systems, the reciprocating WaveOne and the continuous motion F360 files, in the cleaning and contouring of root canals in removed teeth. Materials and method: The 50 central maxillary permanent teeth Data was gathered from the Oral and Maxillofacial Surgery Division at Sri Ganganagar's Maharaja Ganga Singh Dental College and Research Centre for a number of reasons. Group A followed the manufacturer's guidelines for using the WaveOne instrument, whereas Group B utilised the F360. Reciprocating motion WaveOne system (group A) and continuous motion F360 system (group B) root canals were scored at three levels: coronal third, middle third, and apical third (group B). SPSS version 22 was used for the data analysis. The data were examined using the chi-square test and the one-way analysis of variance. Results: A greater quantity of smear layer was found in the apical third, whereas better results were achieved in the coronal and middle thirds. When compared to the F360 file system, the WaveOne file system is subpar when it comes to clearing the canal of debris. While both groups showed a large amount of debris in the apical third, outcomes were somewhat better in the coronal and middle thirds. Conclusion: The WaveOne and F360 file systems were both more effective in removing trash from the coronal and middle thirds of the disc than they were from the apical thirds. In comparison to the continuous motion F360 file system, WaveOne files demonstrated a statistically significant reduction in the amount of debris cleared from root canals in all three root zone thirds (coronal, middle, and apical). The reciprocating action of the WaveOne file system, in contrast to the continuous motion of the F360 file system, resulted in more extensive cleaning of the root canal smear layer in the coronal and middle thirds and less thorough cleaning in the apical thirds of the canal.

15.
PeerJ ; 11: e15208, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37131992

RESUMEN

Backround: OneReci (MicroMega, Besançon, France) is a recently introduced single-file reciprocating system with scarce information revealed on its shaping ability. This study aimed to compare the shaping abilities of OneReci and a well-documented single-file reciprocating system WaveOne Gold (WOG; Dentsply Maillefer, Ballaigues, Switzerland) and evaluate the effect of increased apical enlargement on the preparation quality, using micro-computed tomography (micro-CT). Methods: After an initial micro-CT scanning, twenty mesial root canals of mandibular molars were anatomically matched. The canals were assigned to two experimental groups (n = 10), using OneReci or WOG in different canals of the same root. The glide paths were created, and root canals were prepared twice, using size 25 and 35 instruments of the systems, respectively. The specimens were scanned with micro-CT after each preparation. The increase in canal volume, amount of dentin removal, unprepared root canal surface, canal transportation, centering ratio and preparation times were assessed. The data were analysed with independent sample t-tests, variance analyses, Friedman and Mann-Whitney U tests. The significance level was set at 5%. Results: Each preparation increased the canal volume and dentin removal while decreasing the unprepared root surface. The difference between the systems became significant after preparation with size 35 instruments (p < 0.05). Regarding canal transportation and centering ratio, the difference was insignificant (p > 0.05). The first preparation step (glide path + size 25 instrument) was significantly faster in the OneReci group (p < 0.05). Conclusions: Preparation with size 25 instruments of the systems appeared to be safe with similar shaping performances. Larger apical preparation promoted significantly higher dentin removal, volume increase, and prepared surface area in WOG.


Asunto(s)
Oro , Preparación del Conducto Radicular , Microtomografía por Rayos X/métodos , Diseño de Equipo , Tratamiento del Conducto Radicular
16.
J Endod ; 49(5): 559-566, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36924829

RESUMEN

INTRODUCTION: This study evaluated the effect of traditional and conservative endodontic access cavity designs in combination with WaveOne Gold and TruNatomy instrumentation systems on the fracture resistance of mandibular first molars by means of nonlinear finite element analysis (FEA). METHODS: Micro-CT images of 4 human mandibular first molars were used to generate representative FEA models. The mandibular first molars samples were scanned before and after endodontic access cavity preparation and instrumentation of all 3 canals. Five nonlinear static loads were applied vertically and horizontally to specific contact points on the occlusal surface of the teeth. Maximum von Mises stress before failure and distribution of von Mises strains were recorded and compared between groups. RESULTS: Molars with conservative endodontic access cavities required similar levels of loads to reach failure compared with their control samples, whereas molars with traditional endodontic access cavities required significantly reduced loads in order to fail. According to the numerical investigation, the type of instrumentation system was found to have an insignificant effect on the fracture resistance of the teeth under study. Von Mises stress was concentrated around the cervical region and in the larger distal roots for all numerical models. CONCLUSIONS: The fracture resistance of mandibular first molars is influenced significantly by a reduction in dental hard tissue, which was found to control the level of the ultimate failure load for each tooth.


Asunto(s)
Caries Dental , Diente no Vital , Diente , Humanos , Análisis de Elementos Finitos , Diente Molar , Cavidad Pulpar/diagnóstico por imagen , Preparación del Conducto Radicular
17.
J Endod ; 49(4): 382-389, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36709041

RESUMEN

INTRODUCTION: Root canal treatment (RCT) is often considered a difficult procedure for both the patient and treatment provider. The American Association of Endodontists case difficulty assessment form categorizes cases as minimal, moderate, and high difficulty level. We recently showed that endodontic mishaps occur frequently during treatment of teeth in high difficulty category. The aims were to investigate the clinical and radiographic outcome at least 4 years after RCT and to evaluate patients' perceived oral health-related quality of life (OHRQoL). METHODS: Two hundred thirty-four patients (257 endodontically treated teeth) who were previously included in a quality assurance study were offered a recall appointment at the Department of Clinical Dentistry, University of Bergen, Norway. Patients were given a thorough clinical, radiographic examination and asked to fill out the Oral Health Impact Profile-14 questionnaire. RESULTS: A total of 149 patients (160 teeth) attended the 4-year (range, 4-6 years) recall appointment. An unchanged or lower Periapical Index (PAI) score at recall visit was registered on 153 teeth (95.6%) (P < .001). Radiographic success rate (PAI score ≤ 2) was 87.5%, and clinical success (absence of clinical signs and symptoms) was 88.8%. Both radiographic and clinical success was observed in 78.8% of teeth. Teeth in high difficulty category, instrumented with engine-driven files, and molars presented with significantly more clinical signs and symptoms but not high PAI score (PAI score ≥ 3) (P < .05). Endodontic mishaps such as overinstrumentation and overfill with gutta-percha resulted in significantly high PAI score (P < .05). Patients with no clinical signs and symptoms after RCT and elderly had a significantly better OHRQoL (P < .05). CONCLUSIONS: Presence of clinical signs and symptoms rather than PAI score affected patients' OHRQoL.


Asunto(s)
Tratamiento del Conducto Radicular , Diente , Humanos , Anciano , Estudios de Seguimiento , Tratamiento del Conducto Radicular/métodos , Resultado del Tratamiento , Calidad de Vida
18.
J Endod ; 49(1): 83-88, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36375650

RESUMEN

INTRODUCTION: The purpose of this study was to evaluate and compare 2 different access cavity designs in combination with 2 popular single-file preparation systems to see which combination preserves dentin, more specifically pericervical dentin, best. The minimum remaining dentin thickness and dentin volumes were evaluated pre- and postinstrumentation. METHODS: Sixty extracted human mandibular molars were selected and randomly divided into 2 different access cavity design preparation groups: traditional access cavities (n = 30) and conservative access cavities (n = 30). Within each cavity preparation design group, the 30 teeth were divided into 2 instrumentation groups (WaveOne Gold Primary; Dentsply Sirona, Ballaigues, Switzerland [n = 15] and TruNatomy Prime, Dentsply Sirona [n = 15]). Samples were scanned using micro-computed tomographic imaging before and after access cavity preparation as well as after final endodontic instrumentation. The pericervical remaining dentin thickness and dentin volume changes were evaluated and compared. RESULTS: Conservative access cavity designs resulted in more favorable remaining dentin thickness. The least amount of mean dentin volume loss was also recorded in the conservative access cavity preparation groups regardless of the preparation instrumentation. CONCLUSIONS: In terms of the remaining pericervical dentin thickness and dentin volume reductions, the authors conclude that conservative access cavity designs preserve dentin best.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Humanos , Cavidad Pulpar/diagnóstico por imagen , Oro , Dentina/diagnóstico por imagen
19.
Aust Endod J ; 49(1): 38-47, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35255157

RESUMEN

This study compared shaping ability between two single-file systems and before/after using supplementary file in untouched area, volume of removed dentin, maximum cut depth (the highest cut depth by main file) and remaining thinnest dentin (the thinnest root dentin after preparation). Ribbon-shaped distal canals of mandibular molars were prepared with non-adaptive core (WaveOne Gold) or adaptive core (XP-endo Shaper) files (n = 15/group) and additionally prepared with a supplementary file (XP-endo Finisher), and the shaping ability was investigated using micro-computed tomography. XP-endo Shaper group demonstrated significantly less overall untouched area than WaveOne Gold group (38.21 ± 6.98% vs. 47.68 ± 9.16%) (p < 0.05). No significant difference was detected between XP-endo Shaper and WaveOne Gold groups in volume of removed dentin (1.85 ± 0.53 vs. 1.66 ± 0.33 mm3 ), maximum cut depth (0.10-0.28 vs. 0.10-0.29 mm) and remaining thinnest dentin (0.66-0.80 vs. 0.78-0.88 mm). Supplementary XP-endo Finisher treatment significantly decreased untouched area (11%-23% reduction) (p < 0.05) with minimally cut root dentin (0.01-0.02 mm).


Asunto(s)
Níquel , Titanio , Cavidad Pulpar/diagnóstico por imagen , Oro , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Microtomografía por Rayos X
20.
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1421834

RESUMEN

Evaluar la influencia del operador sobre el transporte apical y centrado de la instrumentación endodóntica utilizando WaveOne Gold en canales radiculares simulados de resina acrílica. Se asignaron 32 canales simulados de resina acrílica a dos grupos (n = 16). El grupo 1 conformado por estudiantes inexpertos y el grupo 2 por especialistas en el área de endodoncia. Estos canales se instrumentaron hasta un tamaño apical de 25/07 con lima Primary WaveOne Gold. Para evaluar el transporte apical y el centrado de la instrumentación se utilizaron imágenes fotográficas que fueron analizadas mediante los software de edición de imagen Photoshop e Image J. Además fue registrada la incidencia de fractura de instrumentos. Los datos fueron registrados mediante un formulario Google Forms y analizados mediante el software estadístico R. Se evaluó la normalidad de los dato s mediante el test Shapiro-Wilk y para establecer diferencias entre los grupos se realizó la prueba t. El nivel de significancia estadística fue establecido en p < 0,05. La mayor diferencia al evaluar el centrado se evidenció a nivel de los 6 mm y en cuanto al transporte apical la mayor discrepancia fue a nivel de 1 mm. Sin embargo, no se observaron diferencias significativas entre ambos grupos e n ninguno de los puntos evaluados. Se reportó una baja incidencia de fractura de instrumentos. La experiencia del operador no influye en la conformación del canal radicular simulado al evaluar centrado y transporte apical al utilizar limas WaveOne Gold.


To evaluate root canal transportation and centering ability as influenced by operator experience using WaveOne Gold files in simulated acrylic resin root canals. Thirty-two simulated acrylic resin canals were distributed to two groups (n = 16). Group 1 is made up of inexperienced students, and group 2 by specialists in the field of endodontics. These canals were shaped to an apical size of 07/25 with the Primary WaveOne Gold file. Photographic images were used to evaluate apical transport and centering of the instrumentation, which was analyzed using Photoshop and Image J image editing software. File separation was also recorded. The data were recorded using Google Forms and analyzed using the R statistical program. The normality of the data was evaluated using the Shapiro-Wilk test, and the t-test was performed to establish differences between the groups. The level of statistical significance was established as p <0.05. The normality of the data was evaluated using the Shapiro-Wilk test. Then statistical significance was analyzed using the T-test. The most remarkable difference when evaluating centering was evident at the 6 mm level. In terms of apical transport, the major discrepancy was at the 1 mm level. However, no significant differences were observed between both groups in any of the points evaluated. A low incidence of instrument fracture was reported. According to our results, the operator's experience does not influence shaping in simulated root canals in terms of centering ability and apical transportation when using WaveOne Gold files.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA