Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Materials (Basel) ; 16(8)2023 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-37109946

RESUMEN

The compression tests under the unidirection for magnetorheological (MR) fluids have been studied at different compressive speeds. The results indicated that curves of compressive stress under different compression speeds at the applied magnetic field of 0.15 T overlapped well and were shown to be an exponent of about 1 of the initial gap distance in the elastic deformation region and accorded well with the description of continuous media theory. The difference in compressive stress curves increases significantly with an increasing magnetic field. At this time, the continuous media theory description could not be accounted for the effect of compressive speed on the compression of MR fluid, which seems to deviate from the Deborah number prediction under the lower compressive speeds. An explanation based on the two-phase flow due to aggregations of particle chains resulting in much longer relaxation times at a lower compressive speed was proposed to explain this deviation. The results have guiding significance for the theoretical design and process parameter optimization for the squeeze-assisted MR devices such as MR dampers and MR clutches based on the compressive resistance.

2.
Materials (Basel) ; 16(4)2023 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-36837277

RESUMEN

An enhanced lightness and thinness is the inevitable trend of modern industrial production, which will also lead to prominent low-frequency vibration problems in the associated structure. To solve the vibration problem of thin plate structures in various engineering fields, the active constrained layer damping (ACLD) thin plate structure is taken as the research object to study vibration control. Based on the FEM method, energy method, and Hamilton principle, the dynamic model of an ACLD thin plate structure is derived, in which the Golla-Hughes-McTavish (GHM) model is used to characterize the damping characteristics of the viscoelastic layer, and the equivalent Rayleigh damping is used to characterize the damping characteristics of the base layer. The order of the model is reduced based on the high-precision physical condensation method and balance reduction method, and the model has good controllability and observability. An LQR controller is designed to actively control the ACLD sheet, and the controller parameters and piezoelectric sheet parameters are optimized. The results show that the finite element model established in this paper is accurate under different boundary conditions, and the model can still accurately and reliably describe the dynamic characteristics of the original system in the time and frequency domain after using the joint reduction method. Under different excitation and boundary conditions, LQR control can effectively suppress structural vibration. Considering the performance and cost balance, the most suitable control parameter for the system is: Q-matrix coefficient is between 1 × 104 and 1 × 105, the R-matrix coefficient is between 1 and 10, and the thickness of the piezoelectric plate is 0.5 mm.

3.
Comput Med Imaging Graph ; 104: 102165, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36599223

RESUMEN

Finite element methods (FEM) are popular approaches for simulation of soft tissues with elastic or viscoelastic behavior. However, their usage in real-time applications, such as in virtual reality surgical training, is limited by computational cost. In this application scenario, which typically involves transportable simulators, the computing hardware severely constrains the size or the level of details of the simulated scene. To address this limitation, data-driven approaches have been suggested to simulate mechanical deformations by learning the mapping rules from FEM generated datasets. Prior data-driven approaches have ignored the physical laws of the underlying engineering problem and have consequently been restricted to simulation cases of simple hyperelastic materials where the temporal variations were effectively ignored. However, most surgical training scenarios require more complex hyperelastic models to deal with the viscoelastic properties of tissues. This type of material exhibits both viscous and elastic behaviors when subjected to external force, requiring the implementation of time-dependant state variables. Herein, we propose a deep learning method for predicting displacement fields of soft tissues with viscoelastic properties. The main contribution of this work is the use of a physics-guided loss function for the optimization of the deep learning model parameters. The proposed deep learning model is based on convolutional (CNN) and recurrent layers (LSTM) to predict spatiotemporal variations. It is augmented with a mass conservation law in the lost function to prevent the generation of physically inconsistent results. The deep learning model is trained on a set of FEM datasets that are generated from a commercially available state-of-the-art numerical neurosurgery simulator. The use of the physics-guided loss function in a deep learning model has led to a better generalization in the prediction of deformations in unseen simulation cases. Moreover, the proposed method achieves a better accuracy over the conventional CNN models, where improvements were observed in unseen tissue from 8% to 30% depending on the magnitude of external forces. It is hoped that the present investigation will help in filling the gap in applying deep learning in virtual reality simulators, hence improving their computational performance (compared to FEM simulations) and ultimately their usefulness.


Asunto(s)
Aprendizaje Profundo , Realidad Virtual , Simulación por Computador
4.
J Biomech Eng ; 145(5)2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36416287

RESUMEN

Biphasic poro-viscoelastic constitutive material model (BPVE) captures both the fluid flow dependent and independent behavior of cartilage under stress relaxation type indentation. A finite element model based on BPVE formulation was developed to explore the sensitivity of the model to Young's modulus, Poisson's ratio, permeability, and viscoelastic constitutive parameters expressed in terms of Prony series coefficients. Then we fit the numerical model to experimental force versus time curves from stress relaxation indents on bovine tibial plateaus to extract the material properties. Measurements were made over the period of two days to capture the material property changes that resulted from trypsin-induced degradation. We measured spatial and temporal changes in mechanical properties in the cartilage. The areas of degradation were characterized by an increase in both permeability and summation of Prony series shear relaxation amplitude constants. These findings suggest that cartilage degradation reduces the intrinsic viscoelastic properties of the solid phase of the tissue in addition to impairing its capacity to offer frictional drag to the interstitial fluid flow (permeability). The changes in material properties are measurable well before structural degradation occurs.


Asunto(s)
Cartílago Articular , Animales , Bovinos
5.
Polymers (Basel) ; 14(23)2022 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-36501679

RESUMEN

Due to current developments in jet engine design, the acoustic performance of conventional acoustic liners needs to be improved with respect to lower frequency spectrums and broadband absorption. In this context, the present study aimed to determine the viscoelastic material properties of a thermoplastic polyurethane (TPU) film for targeted application in novel acoustic liners with integrated film material for enhanced noise reduction. Therefore, a dynamic mechanical analysis (DMA) was performed to determine these viscoelastic material properties. Based on the acquired data, the time-temperature shift (TTS) was applied to obtain the material's temperature- and frequency-dependent mechanical properties. In this regard, the William-Landel-Ferry (WLF) method and an alternative polynomial approach determining the shift factors were investigated and compared. Furthermore, a generalized Maxwell model-so-called Prony-series-with and without pre-smoothing utilizing of a fractional rheological model was applied to approximate the measured storage and loss modulus and to provide a material model that can be used in finite element analyses. Finally, the results were discussed concerning the application of the films in acoustic liners under the conditions of a standard flight cycle and the applied loads. The present investigations thus provide a method for characterizing polymer materials, approximating their mechanical behavior for vibration applications at different ambient temperatures and enabling the identification of their operational limits during the application in acoustic liners.

6.
Bioengineering (Basel) ; 9(11)2022 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-36354583

RESUMEN

BACKGROUND: Aqueous humor outflow resistance in the trabecular meshwork (TM), juxtacanalicular connective tissue (JCT), and Schlemm's canal (SC) endothelium of the conventional outflow pathway actively contribute to intraocular pressure (IOP) regulation. Outflow resistance is actively affected by the dynamic outflow pressure gradient across the TM, JCT, and SC inner wall tissues. The resistance effect implies the presence of a fluid-structure interaction (FSI) coupling between the outflow tissues and the aqueous humor. However, the biomechanical interactions between viscoelastic outflow tissues and aqueous humor dynamics are largely unknown. METHODS: A 3D microstructural finite element (FE) model of a healthy human eye TM/JCT/SC complex was constructed with elastic and viscoelastic material properties for the bulk extracellular matrix and embedded elastic cable elements. The FE models were subjected to both idealized and a physiologic IOP load boundary using the FSI method. RESULTS: The elastic material model for both the idealized and physiologic IOP load boundary at equal IOPs showed similar stresses and strains in the outflow tissues as well as pressure in the aqueous humor. However, outflow tissues with viscoelastic material properties were sensitive to the IOP load rate, resulting in different mechanical and hydrodynamic responses in the tissues and aqueous humor. CONCLUSIONS: Transient IOP fluctuations may cause a relatively large IOP difference of ~20 mmHg in a very short time frame of ~0.1 s, resulting in a rate stiffening in the outflow tissues. Rate stiffening reduces strains and causes a rate-dependent pressure gradient across the outflow tissues. Thus, the results suggest it is necessary to use a viscoelastic material model in outflow tissues that includes the important role of IOP load rate.

7.
J Clin Med ; 11(20)2022 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-36294371

RESUMEN

BACKGROUND: Although the tissues comprising the ocular conventional outflow pathway have shown strong viscoelastic mechanical response to aqueous humor pressure dynamics, the viscoelastic mechanical properties of the trabecular meshwork (TM), juxtacanalicular connective tissue (JCT), and Schlemm's canal (SC) inner wall are largely unknown. METHODS: A quadrant of the anterior segment from two human donor eyes at low- and high-flow (LF and HF) outflow regions was pressurized and imaged using optical coherence tomography (OCT). A finite element (FE) model of the TM, the adjacent JCT, and the SC inner wall was constructed and viscoelastic beam elements were distributed in the extracellular matrix (ECM) of the TM and JCT to represent anisotropic collagen. An inverse FE-optimization algorithm was used to calculate the viscoelastic properties of the ECM/beam elements such that the TM/JCT/SC model and OCT imaging data best matched over time. RESULTS: The ECM of the glaucoma tissues showed significantly larger time-dependent shear moduli compared to the heathy tissues. Significantly larger shear moduli were also observed in the LF regions of both the healthy and glaucoma eyes compared to the HF regions. CONCLUSIONS: The outflow tissues in both glaucoma eyes and HF regions are stiffer and less able to respond to dynamic IOP.

8.
Polymers (Basel) ; 14(18)2022 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-36145896

RESUMEN

Viscoelastic material can significantly reduce the vibration energy and radiated noise of a structure, so it is widely used in lightweight sandwich structures. The accurate and efficient determination of the frequency-dependent complex modulus of viscoelastic material is the basis for the correct analysis of the vibro-acoustic behavior of sandwich structures. Based on the behavior of a sandwich beam whose core is a viscoelastic layer, a combined theoretical and experimental study is proposed to characterize the properties of the viscoelastic layer constituting the core. In this method, the viscoelastic layer is bonded between two constraining layers. Then, a genetic algorithm is used to fit the analytical solution of the frequency¬ response function of the free-free constrained beam to the measured result, and then the frequency-dependent complex modulus is estimated for the viscoelastic layer. Moreover, by varying the length of the beams, it is possible to characterize the frequency-dependent complex modulus of the viscoelastic material over a wide frequency range. Finally, the characterized frequency-dependent complex modulus is imported into a finite element model to compute the complex natural frequencies of a sandwich beam, and a comparison of the simulated and measured results displays that the errors in the real parts are within 2.33% and the errors in the imaginary parts are within 3.31%. It is confirmed that the proposed method is feasible, accurate, and reliable. This provides essential technical support for improving the acoustic vibration characteristics of sandwich panels by introducing viscoelastic materials.

9.
ACS Appl Mater Interfaces ; 14(33): 38398-38408, 2022 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-35947040

RESUMEN

The advancement of flexible electronic devices has prompted new material development for the display application. For flexible display, a suitable clear viscoelastic film (CVF) is essential to bond different layers in a display stack in order to improve the visualization and durability during the repeated folding process. However, it is challenging to integrate different properties in the CVF by overcoming many contradictory requirements, such as low modulus/glass transition temperature (Tg) and high adhesion or high recoverability and good stress-relaxation. In this work, a CVF was prepared using an interpenetrating polymer network (IPN) with bimodal chain length distribution, and it exhibited several favorable properties. The bimodal elastomer was composed of short-chain polyurethane (PU) and long-chain polyacrylate. The long-chain polyacrylate network provided a large amount of entanglement that conferred stretchability, adhesion, and stress-relaxation, whereas the short PU chain network acted as an entropy spring and contributed mostly to the recoverability. The experimental data suggested the presence of a hydrogen-bonding interaction and interlocked polymer chains between the two networks. When the components of the IPN are adjusted, the CVF can simultaneously achieve good stress-relaxation, high strain recovery at large strain (1000%), high toughness, clarity, and adhesion. Moreover, the CVF displayed low glass transition temperature (-57 °C) and low storage modulus (20 to 30 kPa at room temperature). To the best of our knowledge, this is the first report using the IPN concept to prepare a CVF with well-balanced properties.

10.
Proc Inst Mech Eng H ; 236(9): 1414-1429, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35861574

RESUMEN

This paper studies experimentally and analytically the influence of the viscoelastic cardiac muscle on the energy harvesting from heartbeats for powering the leadless pacemakers by using a piezoelectric beam. An appropriate representative gel-type viscoelastic material that mimics the heart tissue is used in the tests. The piezoelectric beam coupled with a gel-type material is analytically modeled, and experimentally tested. By considering a combination of the translational standard linear solid model and a rotational spring component for the gel-type material, the analytical model of the coupled system is developed utilizing the generalized Hamilton's principle. The system is attached on top of a shaker and excited harmonically, and the time history of output voltage and accelerations are measured. The analytical model is verified by experimental results for the tip displacement, voltage, generated power, phase-portraits histories, and voltage FRF with harmonic base excitations. Transmissibility analysis by the analytical model shows that for excitation frequencies beyond a specific frequency, the viscoelastic material can magnify the amplitude of the excitation and incredibly improve the power generation. Experimental results demonstrate that by coupling the gel into the harvester, oscillations of the tip are increased into high energy orbits and large tip deflections around the resonance frequency. The significantly widened frequency bandwidth and the increased power output at specific input frequencies are the other results of considering the viscoelastic characteristics of the heart wall in the dynamic investigations. By simulating the response of the energy harvesting system to the heartbeat impulsive rhythm, when the energy harvesting system is attached to the viscoelastic material, the output power is increased from 18 to 55 µW. The obtained results reveal that influence of the viscoelastic properties of the heart muscle is crucial in the accurate design of the energy harvesting system for the self-powered medical leadless pacemaker.


Asunto(s)
Marcapaso Artificial , Suministros de Energía Eléctrica , Diseño de Equipo , Frecuencia Cardíaca , Miocardio
11.
ACS Nano ; 15(12): 19629-19639, 2021 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-34855345

RESUMEN

Flexible strain sensors have an irreplaceable role in critical and emerging fields, such as electronic skins, flexible robots, and prosthetics. Although numerous efforts have been made to improve sensor sensitivity to meet specific application scenarios, the signal-to-noise ratio (SNR) is an extremely critical and non-negligible indicator, which takes into account higher sensitivity, meaning that they can also detect the noise signals with high sensitivity. Coincidentally, scorpions with ultrasensitive vibration sensilla also face such a dilemma. Here, it is found that the scorpion ingeniously uses the viscoelastic material in front of its slit sensilla to realize efficient preprocessing of the signal. Its mechanism is that the loss factor of materials changes with frequency, affecting energy storage and transmission. Inspired by this ingenious strategy, a bioinspired strain sensor insensitive to a low strain rate was designed using a two-step template transfer method. As a result, its relative change in resistance reached 110% under the same strain (0.3197%) but with different strain rates (0.1 Hz and ∼20 Hz). The noncontact vibration experiments also show different responses to low-frequency vibration and high-frequency impact. Moreover, it can also be used as a typical flexible strain sensor. Under the tensile state, it has a gauge factor (GF) as high as 4596 upon 0.6% strain, and the response time is 140 ms. Therefore, it is expected that this strain sensor will be used in many important ultraprecision measurement fields, especially when the measured signal is small.


Asunto(s)
Dispositivos Electrónicos Vestibles , Vibración
12.
Nanomaterials (Basel) ; 11(11)2021 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-34835725

RESUMEN

Photopolymer nanowires prepared by two-photon polymerization direct laser writing (TPP-DLW) are the building blocks of many microstructure systems. These nanowires possess viscoelastic characteristics that define their deformations under applied forces when operated in a dynamic regime. A simple mechanical model was previously used to describe the bending recovery motion of deflected nanowire cantilevers in Newtonian liquids. The inverse problem is targeted in this work; the experimental observations are used to determine the nanowire physical characteristics. Most importantly, based on the linear three-parameter solid model, we derive explicit formulas to calculate the viscoelastic material parameters. It is shown that the effective elastic modulus of the studied nanowires is two orders of magnitude lower than measured for the bulk material. Additionally, we report on a notable effect of the surrounding aqueous glucose solution on the elasticity and the intrinsic viscosity of the studied nanowires made of Ormocomp.

13.
Front Bioeng Biotechnol ; 9: 693120, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34458242

RESUMEN

Finite Element (FE) modelling of spinal cord response to impact can provide unique insights into the neural tissue response and injury risk potential. Yet, contemporary human body models (HBMs) used to examine injury risk and prevention across a wide range of impact scenarios often lack detailed integration of the spinal cord and surrounding tissues. The integration of a spinal cord in contemporary HBMs has been limited by the need for a continuum-level model owing to the relatively large element size required to be compatible with HBM, and the requirement for model development based on published material properties and validation using relevant non-linear material data. The goals of this study were to develop and assess non-linear material model parameters for the spinal cord parenchyma and pia mater, and incorporate these models into a continuum-level model of the spinal cord with a mesh size conducive to integration in HBM. First, hyper-viscoelastic material properties based on tissue-level mechanical test data for the spinal cord and hyperelastic material properties for the pia mater were determined. Secondly, the constitutive models were integrated in a spinal cord segment FE model validated against independent experimental data representing transverse compression of the spinal cord-pia mater complex (SCP) under quasi-static indentation and dynamic impact loading. The constitutive model parameters were fit to a quasi-linear viscoelastic model with an Ogden hyperelastic function, and then verified using single element test cases corresponding to the experimental strain rates for the spinal cord (0.32-77.22 s-1) and pia mater (0.05 s-1). Validation of the spinal cord model was then performed by re-creating, in an explicit FE code, two independent ex-vivo experimental setups: 1) transverse indentation of a porcine spinal cord-pia mater complex and 2) dynamic transverse impact of a bovine SCP. The indentation model accurately matched the experimental results up to 60% compression of the SCP, while the impact model predicted the loading phase and the maximum deformation (within 7%) of the SCP experimental data. This study quantified the important biomechanical contribution of the pia mater tissue during spinal cord deformation. The validated material models established in this study can be implemented in computational HBM.

14.
Micromachines (Basel) ; 12(8)2021 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-34442573

RESUMEN

This report examines the heat and mass transfer in three-dimensional second grade non-Newtonian fluid in the presence of a variable magnetic field. Heat transfer is presented with the involvement of thermal relaxation time and variable thermal conductivity. The generalized theory for mass flux with variable mass diffusion coefficient is considered in the transport of species. The conservation laws are modeled in simplified form via boundary layer theory which results as a system of coupled non-linear partial differential equations. Group similarity analysis is engaged for the conversion of derived conservation laws in the form of highly non-linear ordinary differential equations. The solution is obtained vial optimal homotopy procedure (OHP). The convergence of the scheme is shown through error analysis. The obtained solution is displayed through graphs and tables for different influential parameters.

15.
Proc Inst Mech Eng H ; 235(10): 1205-1216, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34137313

RESUMEN

In this paper, mechanical parameters of a calf heart muscle are identified and a gel-type material as the representative of the cardiac muscle in dynamic tests is introduced. The motivation of this study is to introduce a replacement material of the heart muscle to use in experimental studies of the leadless pacemaker. A particular test setup is developed to capture the experimental data based on the stress relaxation test method where its outputs are time histories of the force and displacement. The standard linear solid model is used for mathematical modeling of the heart muscle sample and a gel-type material specimen namely α-gel. Five tests with different strain history (13.6%,17.1%,20.6%22.4%and,23.8%) are performed by regarding and disregarding the influence of the initial ramp of the loading. The mechanical parameters of the standard linear solid model were identified with precise curve fitting. Consideration of the initial ramp significantly influences the consequences and they are so close to their experimental counterparts. The identified parameters of the standard linear solid model by regarding the influence of the initial ramp for the gel-type material are within an acceptable range for the viscoelastic properties of the calf heart tissue. These results show that the gel-type material has the potential to represent the cardiac muscle in the leadless pacemaker experimental studies. Dynamic mechanical analysis is used to characterize the dynamic viscoelastic properties for the gel by utilizing the identified parameters with taking into account the initial ramp in the frequency domain. Results show that Storage modulus, Loss modulus, and Loss tangent are strongly frequency-dependent especially at low-frequency around the heartbeat frequency range (0-2 Hz).


Asunto(s)
Modelos Teóricos , Miocardio , Elasticidad , Estrés Mecánico , Viscosidad
16.
J Mech Phys Solids ; 1522021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34092810

RESUMEN

Viscoelastic material properties at high strain rates are needed to model many biological and medical systems. Bubble cavitation can induce such strain rates, and the resulting bubble dynamics are sensitive to the material properties. Thus, in principle, these properties can be inferred via measurements of the bubble dynamics. Estrada et al. (2018) demonstrated such bubble-dynamic high-strain-rate rheometry by using least-squares shooting to minimize the difference between simulated and experimental bubble radius histories. We generalize their technique to account for additional uncertainties in the model, initial conditions, and material properties needed to uniquely simulate the bubble dynamics. Ensemble-based data assimilation minimizes the computational expense associated with the bubble cavitation model, providing a more efficient and scalable numerical framework for bubble-collapse rheometry. We test an ensemble Kalman filter (EnKF), an iterative ensemble Kalman smoother (IEnKS), and a hybrid ensemble-based 4D-Var method (En4D-Var) on synthetic data, assessing their estimations of the viscosity and shear modulus of a Kelvin-Voigt material. Results show that En4D-Var and IEnKS provide better moduli estimates than EnKF. Applying these methods to the experimental data of Estrada et al. (2018) yields similar material property estimates to those they obtained, but provides additional information about uncertainties. In particular, the En4D-Var yields lower viscosity estimates for some experiments, and the dynamic estimators reveal a potential mechanism that is unaccounted for in the model, whereby the apparent viscosity is reduced in some cases due to inelastic behavior, possibly in the form of material damage occurring at bubble collapse.

17.
Foods ; 10(4)2021 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-33916418

RESUMEN

Volume change and large deformation occur in different solid and semi-solid foods during processing, e.g., shrinkage of fruits and vegetables during drying and of meat during cooking, swelling of grains during hydration, and expansion of dough during baking and of snacks during extrusion and puffing. In addition, food is broken down during oral processing. Such phenomena are the result of complex and dynamic relationships between composition and structure of foods, and driving forces established by processes and operating conditions. In particular, water plays a key role as plasticizer, strongly influencing the state of amorphous materials via the glass transition and, thus, their mechanical properties. Therefore, it is important to improve the understanding about these complex phenomena and to develop useful prediction tools. For this aim, different modelling approaches have been applied in the food engineering field. The objective of this article is to provide a general (non-systematic) review of recent (2005-2021) and relevant works regarding the modelling and simulation of volume change and large deformation in various food products/processes. Empirical- and physics-based models are considered, as well as different driving forces for deformation, in order to identify common bottlenecks and challenges in food engineering applications.

18.
Acta Biomater ; 126: 301-314, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33757903

RESUMEN

Cracks in articular cartilage compromise tissue integrity and mechanical properties and lead to chondral lesions if untreated. An understanding of the mechanics of cracked cartilage may help in the prevention of cartilage deterioration and the development of tissue-engineered substitutes. The degeneration of cartilage in the presence of cracks may depend on the ultrastructure and composition of the tissue, which changes with aging, disease and habitual loading. It is unknown if the structural and compositional differences between immature and mature cartilage affect the mechanics of cartilage cracks, possibly predisposing one to a greater risk of degeneration than the other. We used a fibre-reinforced poro-viscoelastic swelling material model that accounts for large deformations and tension-compression non-linearity, and the finite element method to investigate the role of cartilage structure and composition on crack morphology and tissue mechanics. We demonstrate that the crack morphology predicted by our theoretical model agrees well with the histo-morphometric images of young and mature cracked cartilages under indentation loading. We also determined that the crack morphology was primarily dependent on collagen fibre orientation which differs as a function of cartilage depth and tissue maturity. The arcade-like collagen fibre orientation, first discussed by Benninghoff in his classical 1925 paper, appears to be beneficial for slowing the progression of tissue cracks by 'sealing' the crack and partially preserving fluid pressure during loading. Preservation of the natural load distribution between solid and fluid constituents of cartilage may be a key factor in slowing or preventing the propagation of tissue cracks and associated tissue matrix damage. STATEMENT OF SIGNIFICANCE: Cracks in articular cartilage can be detrimental to joint health if not treated, but it is not clear how they propagate and lead to tissue degradation. We used an advanced numerical model to determine the role of cartilage structure and composition on crack morphology under loading. Based on the structure and composition found in immature and mature cartilages, our model successfully predicts the crack morphology in these cartilages and determines that collagen fibre as the major determinant of crack morphology. The arcade-like Benninghoff collagen fibre orientation appears to be crucial in 'sealing' the tissue crack and preserves normal fluid-solid load distribution in cartilage. Inclusion of the arcade-like fibre orientation in tissue-engineered construct may help improve its integration within the host tissue.


Asunto(s)
Cartílago Articular , Colágeno , Matriz Extracelular , Análisis de Elementos Finitos , Modelos Biológicos , Presión , Estrés Mecánico , Ingeniería de Tejidos
19.
Materials (Basel) ; 13(18)2020 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-32948066

RESUMEN

Asphalt rubbers mixed with untreated and plasticized crumb rubbers and a compounding coupling agent were investigated in this study. The low-temperature rheological properties of asphalt rubbers at different aging levels were tested using a dynamic shear rheometer (DSR). An interconversion between linear viscoelastic material functions was used to obtain converted evaluation indexes for the asphalt rubbers at low temperatures. Lastly, the physicochemical characteristics and the microscopic morphology of the asphalt rubbers were evaluated using Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM), respectively. In conclusion, the storage moduli of the asphalt rubbers containing heterogeneous crumb rubbers increased with the plasticized crumb rubber content and the aging level. The converted relaxation moduli were consistent with the change trend of the storage moduli, and the relaxation rate decreased as the plasticized crumb rubber content and the aging level increased. The process of mixing the base asphalt with crumb and plasticized crumb rubbers was physical blending, and the effect of aging on the absorption peak change of asphalt rubber with plasticized crumb rubbers was less than that of asphalt rubber with ordinary crumb rubbers. Aging deteriorated the blending between the crumb rubber and the base asphalt, and a distinct interface appeared between the crumb rubber and the base asphalt. The particle cores of the plasticized crumb rubber in the asphalt rubber were difficult to maintain. Furthermore, as the plasticized crumb rubber content increased, more fine particles stripped off the plasticized crumb rubber after aging.

20.
Materials (Basel) ; 13(19)2020 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-32977638

RESUMEN

Manifold variations of the mechanical behavior of structural woven fabrics appear in the first load cycles. Nevertheless, invariable states, i.e., mechanically saturated states, can be approached by multiple monotonous load cycle biaxial tests. In a state acceptably close to the ideal saturated state, the stress-strain paths reveal the elastic share of the initially inelastic stress-strain paths of woven fabrics. In this paper, the mechanical saturation behavior of two types of PTFE-coated woven glass fiber fabrics is examined and compared to the recently reported saturation behavior of a PVC-coated polyester fabric. With the help of the saturation test data, an extrapolation function is developed that facilitates an estimation of late cycle stiffness behavior based on measured early cycle behavior. Furthermore, the considerable impact of late cycle properties on structural analyses is shown exemplarily in the numerical simulation of a prestressed fabric structure by comparing results achieved from late and early load cycle stiffness parameters.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA