J Arrhythm ; 38(1): 97-105, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35222755

RESUMEN

BACKGROUND: When performing an electrical isolation of ipsilateral pulmonary veins (PVs) for atrial fibrillation, physicians often need additional radiofrequency (RF) ablation in the carina region between the superior and inferior PVs to achieve a right PV isolation because of intercaval bundles between the right PVs and right atrium (RA). We compared the efficacy of a high-power and short-duration ablation guided by unipolar signal modification (UM) with the conventional method (CM) for ablating epicardial connections between the right PV carina and RA. METHODS: The study subjects consisted of patients who underwent an initial box isolation of atrial fibrillation from January 2015 to December 2019 at Nara Medical University Hospital. Among these patients, 94 and 65 patients who met the criteria were assigned to the CM and UM groups, respectively. We retrospectively analyzed the anterior ablation line of the right PV using an electroanatomical mapping system. Patients whose initial ablation line included the right PV carina were excluded. RESULTS: Six and seven patients were, respectively, excluded from the CM and UM groups. Among 88 CM group patients, 21 needed additional right PV carina ablation, while among 58 UM group patients, 30 needed additional right PV carina ablation (p = .001). No anatomical factors were associated with the additional right PV carina ablation. CONCLUSIONS: Compared to the CM group, a box isolation was less achievable without RF ablation at the right PV carina in the UM group. We should consider a long-duration ablation for epicardial connections between the right PV carina and RA.

3.
J Arrhythm ; 37(5): 1260-1269, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34621424

RESUMEN

BACKGROUND: Acute pulmonary vein reconnection (PVR) is associated with long procedure times and large radiofrequency (RF) energy delivery during pulmonary vein isolation (PVI). Although the efficacy of high-power PVI (HP-PVI) has been recently established, the determinants of acute PVR following HP-PVI remain unclear. METHODS: We evaluated data on 62 patients with paroxysmal atrial fibrillation undergoing unipolar signal modification (USM)-guided HP-PVI. A 50-W RF wave was applied for 3-5 seconds after USM. In the segments adjacent to the esophagus (SAEs), the RF time was limited to 5 seconds. Each circle was subdivided into six regions (segments), and the possible predictors of acute PVR, including minimum contact force (CFmin), minimum force-time integral (FTImin), minimum ablation index (AImin), minimum impedance drop (Imp-min), and maximum inter-lesion distance (ILDmax), were assessed in each segment. RESULTS: We investigated 1162 ablations in 744 segments (including 124 SAEs). Acute PVR was observed in 21 (17%) SAEs and 43 (7%) other segments (P = .001). The acute PVR segments were characterized by significantly lower CFmin, FTImin, AImin, and Imp-min values in the segments other than the SAEs and larger ILDmax values in the SAEs. Furthermore, lower Imp-min and larger ILDmax values independently predicted acute PVR in the segments other than the SAEs and SAEs (odds ratios 0.90 and 1.39 respectively). Acute PVR was not significantly associated with late atrial fibrillation recurrence. CONCLUSIONS: Avoiding PVR remains a challenge in HP-PVI cases, but it might be resolved by setting the optimal target impedance drop and lesion distance values.

4.
JACC Clin Electrophysiol ; 6(2): 171-181, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-32081219

RESUMEN

OBJECTIVES: This study sought to validate the accuracy of noncontact electrograms against contact electrograms in the left atrium during sinus rhythm (SR) and atrial fibrillation (AF). BACKGROUND: Noncontact mapping offers the opportunity to assess global cardiac activation in the chamber of interest. A novel noncontact mapping system, which records intracardiac voltage to derive cellular charge sources (dipole density), allows real-time mapping of AF to guide ablation. METHODS: Noncontact and contact unipolar electrogram pairs were recorded simultaneously from multiple locations. Morphology correlation and timing difference of reconstructed electrograms obtained from a noncontact catheter were compared with those from contact electrograms obtained from a contact catheter at the same endocardial locations. RESULTS: A total of 796 electrogram pairs in SR and 969 electrogram pairs in AF were compared from 20 patients with persistent AF. The median morphology correlation and timing difference (ms) in SR was 0.85 (interquartile range [IQR]: 0.71 to 0.94) and 6.4 ms (IQR: 2.6 to 17.1 ms); in AF was 0.79 (IQR: 0.69 to 0.88) and 14.4 ms (IQR: 6.7 to 26.2 ms), respectively. The correlation was stronger and the timing difference was less when the radial distance (r) from the noncontact catheter center to the endocardium was ≤ 40 versus > 40 mm; 0.87 (IQR: 0.72 to 0.94) versus 0.73 (IQR: 0.56 to 0.88) and 5.7 ms (IQR: 2.6 to 15.4 ms) versus 15.1 ms (IQR: 4.1 to 27.7 ms); p < 0.01 when in SR; 0.81 (IQR: 0.69 to 0.89) versus 0.67 (IQR: 0.45 to 0.82) and 12.3 ms (IQR: 5.9 to 21.8 ms) versus 28.3 ms (IQR: 16.2 to 36.0 ms); p < 0.01 when in AF. CONCLUSIONS: This novel noncontact dipole density mapping system provides comparable reconstructed atrial electrogram measurements in SR or AF in human left atrium when the anatomical site of interest is ≤40 mm from the mapping catheter.


Asunto(s)
Fibrilación Atrial/fisiopatología , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos/fisiopatología , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
5.
Circ Arrhythm Electrophysiol ; 12(8): e007311, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31345092

RESUMEN

BACKGROUND: Both contact force monitoring (CFM) and unipolar signal modification (USM) are guides for ablation, which improve the efficacy of pulmonary vein isolation of atrial fibrillation. We sought to compare the outcomes of atrial fibrillation ablation guided by CFM or USM. METHODS: A total of 136 patients with paroxysmal atrial fibrillation underwent a circumferential pulmonary vein isolation using CF sensing ablation catheters and were randomly assigned to undergo catheter ablation guided by either CFM (CFM-guided group: n=70) or USM (USM-guided group: n=66). In the USM-guided group, each radiofrequency application lasted until the development of completely positive unipolar electrograms. In the CFM-guided group, a CF of 20 g (range, 10-30 g) and minimum force-time integral of 400 g were the targets for each radiofrequency application. The primary end point was freedom from any atrial tachyarrhythmia recurrence without antiarrhythmic drugs at 12-months of follow-up. RESULTS: The cumulative freedom from recurrences at 12-months was 85% in the USM-guided group and 70% in the CFM-guided group (P=0.031). The incidence of time-dependent and ATP-provoked early electrical reconnections between the left atrium and PVs, procedural time, fluoroscopic time, and average force-time integral, did not significantly differ between the 2 groups. The radiofrequency time for the pulmonary vein isolation was shorter in the USM-guided group than CFM-guided group but was not statistically significant (P=0.077). CONCLUSIONS: USM was superior to CFM as an end point for radiofrequency energy deliveries during the pulmonary vein isolation in patients with paroxysmal atrial fibrillation in terms of the 12-month recurrence-free rate. CLINICAL TRIAL REGISTRATION: URL: https://www.umin.ac.jp/ctr/index.htm. Unique identifier: UMIN000021127.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Monitoreo Intraoperatorio/métodos , Cirugía Asistida por Computador/métodos , Fibrilación Atrial/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/cirugía , Resultado del Tratamiento
6.
J Innov Card Rhythm Manag ; 8(4): 2690-2699, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32494447

RESUMEN

Current signal recording and processing systems have come a long way since their initial inception and use. There is, however, still ample scope for improvement, not only in the troubleshooting of their limitations, but also in the expansion of the boundaries in the recording of intracardiac signals. Here, we recount our experience with the use of the PURE EP™ signal recording system (BioSig Technologies, Inc., Minneapolis, MN, USA) in the animal laboratory.