1.
J Formos Med Assoc ; 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39117548

RESUMEN

BACKGROUND: This study explores the utilization patterns of premium and nonpremium intraocular lenses (IOLs) under Taiwan's National Health Insurance, given the potential out-of-pocket expenses incurred by cataract surgery patients. METHODS: A cross-sectional, population-based analysis was performed on patients who underwent IOL implantation between 2016 and 2020. IOLs were categorized into nonpremium and premium, with the latter further divided based on function. Logistic and multinomial logistic regression analyses were employed to identify factors influencing IOL implantation, with data stratified by medical institute type, ownership, and patient demographics. RESULTS: In total, 1,194,805 IOLs were implanted during the study period. The rate of premium IOL implantation was lower compared to non-premium IOL implantation. However, the adoption rate of premium IOLs increased more rapidly than that of non-premium IOLs. Specifically, the adoption rate for premium IOLs was 35.2% in 2016, rising to 42.6% in 2020. Patients receiving treatment in clinics were considerably more likely to use nonpremium IOLs than were those receiving treatment in medical centers (12.7% higher probability for clinics; P < 0.001). The implantation of higher-end premium IOLs was more prevalent in clinics than in other medical institutes. The prevalence of premium IOL implantation was higher in private hospitals than in public hospitals (odds ratio: 1.403; P < 0.001). Premium IOLs were more commonly implanted in younger patients with higher income levels and without relative contraindications. CONCLUSIONS: IOL selection is associated with both personal and institutional characteristics. These factors should be considered in public policy development aimed at regulating the IOL market within a universal health insurance framework.

2.
Case Rep Ophthalmol ; 14(1): 307-313, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37485245

RESUMEN

The purpose of the present case is to report the visual outcomes of a pseudophakic patient with high post-penetrating keratoplasty astigmatism treated with implantation of toric AddOn® intraocular lens (IOL) in the sulcus. A 79-year-old man with a ophthalmologic history of pseudoexfoliative glaucoma and Fuchs endothelial dystrophy had a graft failure after Descemet's stripping automated endothelial keratoplasty procedure on his right eye. Consequently, a penetrating keratoplasty was performed, and a high corneal astigmatism of -9.8 D to 140° resulted in that eye after selective suture removal. A secondary AddOn® toric IOL customized for the patient with a manufacturer-calculated power of +11.0 D was implanted to 50° in sulcus of the right eye. Subjective refraction was used for IOL calculation. Final refraction was +1.0 D of sphere and -2.0 D of cylinder power to 105°, with spherical equivalent of 0.0 D. Best corrected visual acuity was logMAR 0.1 (20/25, 0.8 decimal) 1 year after the IOL implant. Our case report demonstrates that the toric AddOn® secondary IOL can be effective and safe in correcting residual refractive error of high regular astigmatism after keratoplasty in pseudophakic eyes.

3.
Healthcare (Basel) ; 10(9)2022 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-36141385

RESUMEN

(1) Background: To compare the results of a new intraoperative contactless device (INTEGRA Optomed, Poland) with the result of a manual method for determining the axis for toric intraocular lens implantation. (2) Material and Methods: This retrospective observational study included 60 eyes of 40 patients (17 men, 23 women) who had toric intraocular lenses implanted. A video recording of each surgery that used the INTEGRA system was made for the analysis. Two researchers then independently assessed the location of the implant axes determined with both digital and manual slit-lamp methods, and compared the results between methods. (3) Results: The implantation axes suggested through the manual and INTEGRA methods were similar. The median axis disparities were 0.0 degrees for both groups. The standard deviation was 0.63 and 0.75 for researcher 1 and 2, respectively. The dominant value was 0.0 in both groups. The INTEGRA axis designation was statistically significantly different from the manual method for researcher 1 (p < 0.05), but it was statistically insignificant for researcher 2 (p = 0.79). (4) Conclusions: The INTEGRA system is a digital ink-free device for image tracking scleral vessels. It was helpful for determining the implantation axis in a precise manner, and the measurements were comparable with those obtained through a manual technique.

4.
Int J Ophthalmol ; 15(3): 420-425, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35310054

RESUMEN

AIM: To assess the relationship between axial length (AL) and intraocular lens (IOL) rotation among eyes receiving a toric IOL and subsequently entered into an online toric back-calculator database. METHODS: Retrospective analysis of data collected online via astigmatismfix.com, a freely available online toric back-calculator where surgeons enter pre- and post-operative information to help manage residual postoperative astigmatism. Included records were deemed valid with entry of AL and IOL orientation between January 2017 and March 2019. Rotation was determined by a difference of ≥5° between pre-operative intended IOL orientation and actual post-operative IOL orientation. Frequency and magnitude of rotation are presented with means and associated standard deviation (SD). Linear regression models of this association are presented. RESULTS: Records of 6752 eyes were included in the analysis, of which 74.8% were determined to have a rotated IOL. The magnitude of rotation increased with each millimeter (mm) increase in AL with a mean rotation of 13.3° (SD: 12.8°) for eyes with AL 20-20.9 mm and a maximum mean rotation of 30.6° (SD: 30.3°) among eyes with AL 29-29.9 mm. General linear modeling demonstrated a significant association (P<0.0001) with a parameter estimate of 1.19 (standard error: 0.159) and R 2 of 0.0083. CONCLUSION: Analysis from an online database indicates that toric IOLs inserted into eyes with longer AL are more likely to rotate and to rotate more degrees from the target axis. The findings from this study are clinically relevant for surgeons implanting toric IOLs.

5.
Biomed Hub ; 6(1): 30-41, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33791315

RESUMEN

OBJECTIVES: The aim of this study was to assess the clinical outcomes, predictability of results, efficiency of astigmatism correction, and rotational stability of the Bi-Flex 677TAY (Medicontur Medical Engineering Ltd., Zsámbék, Hungary) monofocal toric intraocular lens (IOL) designed for cataract patients with astigmatism. METHODS: The IOLs were implanted either mono- or binocularly, following routine cataract surgery. Visual and refractive outcomes, as well as off-axis rotation were assessed throughout a 1-year follow-up period. All clinical data for this work were collected retrospectively. Vector analysis based on the Alpins method was performed to assess the efficiency of astigmatism correction. RESULTS: No complications or adverse events occurred during surgery or the follow-up period. IOL implantation brought 88% of eyes into the ±0.50 D, and 100% into the ± 1.00 D range compared to the target spherical equivalent refraction, emmetropia. Astigmatism correction brought similar results: 94% of eyes had a residual cylindrical error of not higher than ±0.50 D, and 97% were within ±1.00 D. Vector analysis resulted in a correction index of 0.96 and a difference vector of 0.17. Both refractive and visual outcomes showed long-term stability. During the 12-month follow-up period, no eyes had a rotation of >5°. Absolute rotation after 1 year was 1.42 ± 1.89° (median = 0°), while signed rotation was 1.06 ± 2.12° (median = 0°). CONCLUSION: The Bi-Flex 677TAY monofocal toric IOL, designed by Medicontur Medical Engineering Ltd., represents an efficient and safe solution for cataract patients with astigmatism. Clinical and refractive outcomes are predictable, and rotational stability ensures long-term visual comfort.

6.
Cont Lens Anterior Eye ; 44(6): 101386, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33423977

RESUMEN

PURPOSE: While knowledge of the ocular surface sagittal height (OC-SAG) is increasing with newer instrumentation, understanding of soft lens sag values (CL-SAG) in daily clinical practice is limited. This study aimed to report the differences in CL-SAG of a large collection of daily disposable (DD), reusable (2-week and 4-week replacement) and toric lens designs. METHODS: 12 different spherical DD and 15 reusable lens types were analysed (labelled power -3.00D); 17 different toric lens types analysed (6 DD and 11 reusable) in -3.00D =C 0.75 × 180. Posterior CL-SAG was measured directly using a spectral domain OCT-based instrument (Optimec is830). RESULTS: The range in CL-SAG for DDs was 3,398-3,912 microns, for reusable lenses 3,372-4,004 microns and for toric lenses 3,536-4,157 microns. Lens diameter and BC together influence CL-SAG values. For lenses with the same labelled base curve (BC), the maximum difference in the DD group was 264 microns, in the reusable group 418 microns and in the toric group 345 microns. Three lens designs within the DD group and five in the reusable group offer two BCs, with an average variation (±SD) in CL-SAG of 276 ± 39 microns; one toric lens with two BCs showed a 377-micron difference. CONCLUSIONS: Marked differences in CL-SAG values were found in this study, also between lenses of the same BC. While ECPs should be aware that diameter and BC together influence CL-SAG, this also indicates that lens substitution based on BC alone could result in substantial differences in CL-SAG, with a potential impact on lens fit. Lens designs offering two BCs showed a somewhat narrow band in absolute terms in CL-SAG, and switching from a spherical to a toric lens of the same lens manufacturer could result in a significant change in CL-SAG.


Asunto(s)
Lentes de Contacto Hidrofílicos , Cristalino , Humanos
7.
BMC Ophthalmol ; 20(1): 454, 2020 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-33208137

RESUMEN

BACKGROUND: To prospectively evaluate surgical results following implantation of rotationally asymmetric, plate-haptic, refractive segmented multifocal toric intraocular lenses (IOLs) with near addition of + 1.5 diopters (D) (Lentis Comfort LS-313 MF15T, Oculentis GmbH). METHODS: In 59 eyes of 41 patients, ocular examinations were conducted before and 1 day, 1 week, 1, 3, and 6 months after surgery. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity at 70 cm, and uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity at 30 cm were tested. A defocus curve was drawn, and the degree of disturbing photic phenomena were questioned. RESULTS: The IOL showed excellent rotational stability; the average absolute rotation was 1.66 ± 1.17 degrees from 1 day 1 to 6 months postoperatively, and 98.1 and 100% of eyes yielded rotation of less than 5 and 10 degrees, respectively. Postoperative distance and intermediate visual acuity were highly satisfactory; UDVA, CDVA, UIVA, and DCIVA were about 20/20, 20/16, 20/25, 20/25, respectively. Near visual acuity was suboptimal; UNVA and DCNVA were at approximately 20/60. The defocus curve analysis showed that 20/25 and 20/40 uncorrected visual acuity was attained at as close as 60 and 40 cm, respectively. Contrast sensitivity was within a normal range, and subjective photic phenomena were minimum. CONCLUSIONS: The refractive segmented, rotationally asymmetric multifocal toric IOLs with + 1.5 D near addition showed superb rotational stability and highly satisfactory distance and intermediate vision. Contrast sensitivity was high and incidence of photic symptoms was very low. TRIAL REGISTRATION: This study was registered at JAPIC Clinical Trials Information, ID: JapicCTI-183,877, https://www.clinicaltrials.jp/cti-user/trial/Search.jsp (February 5, 2018).


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares , Estudios Prospectivos , Diseño de Prótesis , Seudofaquia , Refracción Ocular
8.
Am J Ophthalmol Case Rep ; 19: 100754, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32551399

RESUMEN

PURPOSE: To describe a patient who developed radial displacement of the capsular bag and toric intraocular lens implant within approximately 5 weeks after surgery. OBSERVATIONS: A patient underwent uncomplicated cataract extraction and implantation of a toric IOL for 2.5 diopters (D) of preoperative corneal astigmatism. Uncorrected visual acuity (UCVA) on postoperative day 1 was 20/20. Blurriness developed 5 weeks after surgery when UCVA was 20/70 but corrected to 20/20 with 2 D of cylinder in a new axis. The IOL was in the proper axis, but it and the capsular bag were radially displaced. Dilated examination revealed posterior capsular opacification superotemporally, outside the visual axis. The patient's biometry revealed axial myopia and megalocornea (white-to-white measurement of 13.44 mm), suggesting a larger than average capsular bag. Surgery was performed at postoperative week 6 to expand the capsular bag using a capsular tension ring and to re-center the IOL keeping the same axis. The patient recovered UCVA of 20/25 after the IOL was recentered. CONCLUSIONS AND IMPORTANCE: It is important to review biometry for large white-to-white measurements. Eyes with megalocornea may require capsular tension rings at time of toric IOL implantation so as to maintain IOL centration and good UCVA.

9.
Am J Ophthalmol Case Rep ; 18: 100693, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32368687

RESUMEN

PURPOSE: Surgical management of keratoconus aims to improve corneal curvature, prevent progression of corneal ectasia, and manage refractive error. In older individuals with concurrent cataracts, management can be challenging due to topographic irregularity and difficult-to-interpret IOL calculations. We describe a sequential combination of two surgical techniques-intrastromal corneal ring segments (e.g. intacs) insertion and toric pseudoaccomodating lens implantation-to successfully manage concurrent keratoconus and cataracts. OBSERVATIONS: In this case series, we present three eyes with corneal ectasia in two cataractous patients successfully managed by (1) Intacs placement to normalize corneal contour/asymmetry and enable more regular keratometry measurements, followed by (2) correction of astigmatism and presbyopia by placement of toric pseudoaccommodating IOL (Trulign) after cataract extraction. CONCLUSIONS AND IMPORTANCE: This is the first description, to the authors' knowledge, of the use of intraocorneal ring segments + toric pseudoaccommodating intraocular lenses for the management of concurrent keratoconus, cataract, and presbyopia.

10.
Graefes Arch Clin Exp Ophthalmol ; 258(2): 345-350, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31863399

RESUMEN

PURPOSE: To evaluate refractive outcomes for a standard industry calculator using anterior corneal astigmatism or total corneal refractive power. METHODS: This prospective interventional study evaluated the refractive outcomes of 56 eyes using a standard industry calculator (Zeiss ZCalc) and a digital IOL alignment software. After A-constant optimisation the ZCalc was recalculated with two different keratometry values using appropriate refractive indices: anterior corneal astigmatism (ACA) by IOLMaster 700 and total corneal refractive power (TCRP) by Pentacam. The Barrett toric calculator was used as a reference. RESULTS: Undercorrection of 0.04 ± 0.42 D after 1 week and 0.13 ± 0.48 D after 3 months was achieved for the spherical equivalent by using a standard industry calculator. IOL misalignment was 2.8° ± 3.4° using a digital alignment system. For the ZCalc, the mean absolute error could be reduced from 0.19 ± 0.40 D using ACA to 0.04 ± 0.48 D when considering total corneal refractive power (p = 0.06). The Barrett calculator delivered better refractive outcomes than using a standard industry calculator with ACA measurements only (- 0.06 ± 0.43 D; p < 0.01). CONCLUSION: Reliable and accurate refractive outcomes in toric IOL calculation were achieved by using the ZCalc calculator. The prediction error for a widely used standard industry toric IOL calculator could be reduced by using measured total corneal refractive power.


Asunto(s)
Astigmatismo/cirugía , Córnea/patología , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares , Óptica y Fotónica , Refracción Ocular , Agudeza Visual , Adulto , Anciano , Anciano de 80 o más Años , Astigmatismo/diagnóstico , Astigmatismo/fisiopatología , Biometría , Topografía de la Córnea , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis
11.
Rev. bras. oftalmol ; 77(3): 119-123, May-June 2018. tab
Artículo en Portugués | LILACS | ID: biblio-959081

RESUMEN

Resumo Objetivo: A catarata é a principal causa de cegueira reversível no mundo e seu tratamento é baseado em cirurgia, facectomia. A evolução do procedimento tem se baseado em vários pilares, mas é no desenvolvimento de novos tipos de lentes intraoculares que vem mostrando inovações consideráveis. As lentes atuais são capazes, além de tratar a catarata, de corrigir erros refracionais. O objetivo deste estudo foi avaliar a qualidade de vida e de visão pós-facectomia, comparando as lentes multifocais (Restor), tóricas, monofocais esféricas (SN60AT) e monofocais asféricas. Métodos: A pesquisa abrangeu 54 pacientes submetidos a facectomia com implantação de uma das lentes há, pelo menos, 3 meses. Os pacientes responderam questionário de qualidade de vida Cataract TyPE Specification sobre satisfação de visão, dependência de óculos para diversas atividades diárias e presença de fenômenos disfóticos. Para análise dos dados foram utilizados os testes de Kolmogorov-Smirnov, quanto a normalidade e ANOVA com teste de Tukey, quanta parametria. Em comparações não paramétricas, utilizou-se o teste de Mann-Whitney. Em todas as análises foi usado o mesmo nível de significância (p<0,05). Resultados: Numa escala de 0 a 10, a pesquisa mostrou que as lentes SN60AT, esféricas monofocais, foram as que obtiveram menor nível de satisfação entre as 4 lentes, obtendo média de 8,7 (DP= 1,30; IC ± 0,655), seguido das esféricas monofocais (média= 8,3 - DP= 1,83; IC ± 0,927), das esféricas multifocais (Restor) (média = 8,9 - DP = 1,42; IC ± 0,721) e as tóricas (média = 9,1 - DP = 1,67; IC ± 0,844) como a de maior nível de satisfação. Em relação à dependência dos óculos, a lente Restor foi a que mostrou melhor desempenho, com menor dependência dos óculos. Fenômenos disfóticos foram mais frequentes nos pacientes que tiveram implantada a lente SN60AT seguida de lente Restor. Conclusão: Conclui-se que as lentes SN60AT foram as lentes que causaram menor grau de satisfação, tendo os fenômenos disfóticos umas das principais queixas, associada a dependência dos óculos pós-cirurgia. Os pacientes que tiveram as lentes Restor implantadas, apesar dos sintomas disfóticos mais presentes do que as lentes monofocais tóricas e monofocais esféricas, tem o mesmo nível de satisfação, e ainda proporciona maior independência dos óculos.


Abstract Objective: Cataract is the leading cause of reversible blindness in the world and its treatment is based on surgery, facectomy. The evolution of the procedure has been based on several pillars, but it is in the development of new types of intraocular lenses that has been showing considerable innovations. Current lenses are capable, in addition to treating cataracts, of correcting refractive errors. The aim of this study was to evaluate the quality of life and post-facectomy vision, comparing multifocal lenses (Restor), toric, spherical monofocals (SN60AT) and aspheric monofocals. Methods: The study included 54 patients undergoing a facectomy with implantation of one of the lenses for at least 3 months. The patients answered questionnaire quality of life Cataract TyPE Specification on vision satisfaction, glasses dependence for various daily activities and presence of dysphothetic phenomena. For the analysis of the data, the Kolmogorov-Smirnov tests were used, regarding normality and ANOVA with Tukey's test, how much parametric. In non-parametric comparisons, the Mann-Whitney test was used. In all analyzes, the same level of significance was used (p <0.05). Results: On a scale of 0 to 10, the research showed that single-spherical spherical SN60AT lenses were the ones that obtained the lowest level of satisfaction among the four lenses, obtaining an average of 8.7 (SD = 1.30, CI ± 0.655), followed (mean = 8.9 - SD = 1.42, CI ± 0.721) and the toric (mean = 8.3 - SD = 1.83, CI ± 0.927), multifocal spherical (Restor) 9.1 - SD = 1.67, CI ± 0.844) as the highest level of satisfaction. Regarding the dependence of the glasses, the Restor lens showed the best performance, with less dependence on the glasses. Dysphasic phenomena were more frequent in patients who had implanted the SN60AT lens followed by Restor lens. Conclusion: It is concluded that the SN60AT lenses were the lenses that caused less satisfaction, and the dysphothetic phenomena were one of the main complaints, associated with the postoperative glasses dependence. Patients who had restored Restor lenses, despite the more present dysphoric symptoms than spherical monofocal and single-focal lenses, have the same level of satisfaction, and still provide greater independence of the glasses.


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Calidad de Vida , Extracción de Catarata/psicología , Implantación de Lentes Intraoculares/psicología , Lentes Intraoculares , Periodo Posoperatorio , Visión Ocular , Extracción de Catarata/métodos , Agudeza Visual , Estudios Prospectivos , Encuestas y Cuestionarios , Satisfacción del Paciente , Implantación de Lentes Intraoculares/métodos , Anteojos/psicología
12.
Artículo en Inglés | MEDLINE | ID: mdl-29644243

RESUMEN

This study was performed to evaluate the visual, refractive, and aberration measurement results of 2 implants, including Intacs Intracorneal Ring Segments (ICRS) and phakic Toric Implantable Collamer Lens (TICL), in patients with moderate Keratoconus (KCN). In this retrospective cross-sectional study, 30 patients with KCN with a mean age of 29.83 years were included in 2 groups, including the Intacs Intracorneal Ring Segments (ICRS) group and the phakic Toric Implantable Collamer Lens (TICL) group. Preoperative data as well as 6-month, 1-, 2-, 3- and 4-year follow-up data after the operation were collected and analyzed with the SPSS software (ver. 23.0, SPSS, Inc., Chicago, IL), using the paired t-test, independent t-test, repeated measures Analysis of Variance (ANOVA), and one-way ANOVA. This study included 30 patients with KCN with a mean age of 29.83 years and range of 25 to 35 years, including 17 males with a mean age of 30.11 years and 13 female with a mean age of 29.25 years. Except for preoperative Uncorrected Distance Visual Acuity (UCDVA), Spherical Equivalent (SE) and astigmatism, there was a significant difference between the 2 groups regarding other variables. The TICL group had a significantly better UCDVA and Best Corrected Distance Visual Acuity (BCDVA) in all post-operative follow-ups, and SE and astigmatism values were significantly lower in all post-operative follow-ups when compared with the ICRS group. There was a significant reduction in corneal and total coma as well as internal trefoil aberrations (P<0.01, P<0.01, and P=0.014, respectively) in the ICRS group, and TICL led to a significant reduction in internal trefoil aberration with P<0.03. Comparison of the 2 groups revealed a significant difference in corneal spherical (P<0.01) and total coma (P=0.02) aberrations and no significant differences in other HOA. Both ICRS and TICL are useful in patients with moderate KCN. However, TICL appears to have more stable and predictable vision results.

13.
Case Rep Ophthalmol ; 6(1): 132-8, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25969687

RESUMEN

PURPOSE: To describe a patient complaining of 'ghosting' and 'shadowing' after bilateral, sequential cataract extraction with toric intraocular lens (IOL) implantation who was found to have significant eyelid ptosis. METHODS: The following is a case report. RESULTS: The patient's complaints arose a few weeks after surgery. By the second postoperative month, the patient's keratometry had changed compared to preoperative measurements. Because of significant ptosis, the patient underwent upper eyelid surgery. Four months later, he was found to have less corneal astigmatism than had been measured prior to cataract surgery. Following 2 stable examinations, a Prevue lens based on Hartmann-Shack wavefront aberrometry was made for each eye, which the patient said significantly improved his quality of vision. Wavefront-guided photorefractive keratectomy (PRK) was performed 6 months after cataract surgery. One year after PRK, the patient's symptoms had disappeared, his uncorrected visual acuity was 20/20 in the right eye and 20/15 in the left, and he was satisfied with his quality of vision. CONCLUSIONS: Bilateral toric IOLs were implanted in this patient based on measurements of corneal astigmatism that changed after cataract surgery and changed further after ptosis repair. This case demonstrates the importance of evaluating eyelid position in cataract surgical planning as ptosis can contribute significantly to corneal astigmatism. Patient education is important in the setting of higher expectations from purchase of premium lens implants.

14.
Cont Lens Anterior Eye ; 38(3): 194-8, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25704463

RESUMEN

PURPOSE: The aim of the study was to evaluate the objective and subjective visual performance of custom toric contact lenses (TL) and their spherical off-the-shelf counterparts (SL) in subjects with low amounts of astigmatism. METHODS: Twenty-three habitual soft lens wearers (40 eyes, 25-35 years) manifesting 0.50-1.00DC and ≤±3.00DS were recruited. Air Optix Aqua (Lotrafilcon B) was fit using the spherical equivalent of the manifest refraction. Intelliwave toric in Efrofilcon A (Definitive) was fit using the manifest refraction and keratometric data. Comprehensive visual performance tests were done through manifest refraction in a trial frame; in SL; and in TL. A subjective evaluation of quality of vision was also obtained. RESULTS: ANOVA revealed that, at the morning visit (AM), high contrast logMAR distance visual acuity (HCDVA) was significantly better (p<0.01) in spectacles as compared to SL. A similar trend was noted at the afternoon visit (PM). In addition, at the PM visit, HCDVA was significantly better (p<0.01) for TL as compared to their SL. ANOVA revealed that, at the PM visit, low contrast distance visual acuity (LCDVA) was significantly better (p=0.05) in spectacles as compared to SL. None of these differences were clinically significant. In addition, no statistically significant difference (p>0.05) in subjective vision rating scores was noted between SL and TL. CONCLUSIONS: The present investigation found no clinically significant difference in visual performance between spherical and toric soft contact lenses in low astigmats.


Asunto(s)
Astigmatismo/rehabilitación , Lentes de Contacto Hidrofílicos , Refracción Ocular/fisiología , Adulto , Diseño de Equipo , Femenino , Humanos , Masculino
15.
Cont Lens Anterior Eye ; 37(5): 346-50, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24894546

RESUMEN

PURPOSE: To compare lens orientation and rotational recovery of five currently available soft toric lenses. METHODS: Twenty subjects were recruited and trialed with each of the study lenses in a random order. Study lenses were PureVision(®) Toric (B&L), Air Optix(®) for Astigmatism (Alcon), Biofinity(®) Toric (CooperVision), Acuvue(®) Advance for Astigmatism (Vistakon), and Proclear(®) Toric (CooperVision). Lens orientation in primary position to determine the lens rotation form the vertical position and rotational recovery to primary gaze orientation following a 45° manual misorientation for the different lenses was compared. RESULTS: The Biofinity Toric showed the lowest rotation from the vertical position and the Proclear Toric the highest. Also, the highest and the lowest reorientation speed were related to the Biofinity Toric and the Acuvue Advance for Astigmatism, respectively. The Repeated Measures ANOVA showed a significant difference in the lens rotation (P=0.004) and rotational recovery (P<0.001) among different contact lenses and the performed multiple comparisons indicated differences in rotation and also in reorientation speed were only seen between the Biofinity Toric when compared to four other lenses (P<0.05). CONCLUSION: Although there was appropriate fitting, based upon lens orientation and reorientation speed, with each of the study lenses it would appear that the optimized ballast technique used in the design of the Biofinity Toric helps reduce lens rotation and improve rotational recovery compared to others.


Asunto(s)
Astigmatismo/terapia , Lentes de Contacto Hidrofílicos , Ajuste de Prótesis , Refracción Ocular/fisiología , Astigmatismo/fisiopatología , Femenino , Humanos , Masculino , Diseño de Prótesis , Adulto Joven