Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros











Intervalo de año de publicación
1.
Materials (Basel) ; 17(13)2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38998383

RESUMEN

This paper aims to investigate the strengthening mechanism of laser shock peening on the interfacial bonding properties between TiN coatings and TC4 titanium alloy substrates. The different surface textures were induced by LSP on a TC4 titanium alloy substrate. Subsequently, titanium nitride (TiN) coatings were deposited on the surface texture. A scratch test and reciprocating sliding wear assessment were conducted to evaluate the impact of LSP on the interfacial bonding properties and wear performance of the coatings. The experimental results demonstrated that the adhesion of TiN coatings deposited on the surface texture formed by laser shock peening was significantly enhanced. The efficacy of laser shock treatment in reducing wear rates was found to be significantly enhanced in cases of both increased spot overlapping rate and increased laser power density. The surface texture created using laser parameters of 6.43 GW/cm2 and a 50% overlapping rate was found to have the most significant effect on improving the adhesion and anti-wear properties of the coating. The laser shock texture was identified as the main contributor to this improvement, providing a large interfacial contact area and a mechanical bond between the coating and the substrate. This bond inhibited the initiation and propagation of micro-cracks caused by the concentration of internal stress and interfacial stress of the coating.

2.
Materials (Basel) ; 16(11)2023 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-37297101

RESUMEN

The influence of various process parameters on the deep drawing process is a current research topic in sheet metal forming technology. Starting from the application of the previously constructed original testing device, an original tribological model was developed based on the process of sheet metal strip sliding between flat contact surfaces under variable pressures. A complex experiment was executed using an Al alloy sheet, tool contact surfaces of different roughness, two types of lubricants and variable contact pressures. The procedure included analytically pre-defined contact pressure functions based on which, for each of the mentioned conditions, the dependencies of the drawing forces and friction coefficients were obtained. The pressure in function P1 constantly decreased from a high initial value until the minimum, while in function P3 the pressure increased until the minimum value at the halfway point of the stroke, after which it increased up to the initial value. On the other hand, the pressure in function P2 constantly increased from the initial minimum value until the maximum value, while in function P4 the pressure increased until reaching the maximum value at the halfway point of the stroke, after which it decreased to the minimum value. This enabled the determination of the influence of tribological factors on the process parameters of intensity of traction (deformation force) and coefficient of friction. The pressure functions starting with decreasing trends produced higher values for the traction forces and the friction coefficient. In addition, it was established that the roughness of the contact surfaces of the tool, especially those with titanium nitride coating, has a significant influence on the process parameters. For surfaces of lower roughness (polished), a tendency of the Al thin sheet to form a glued-on layer was noticed. This was especially prominent for lubrication with MoS2-based grease under conditions of high contact pressure (functions P1 and P4 at the beginning of the contact).

3.
Materials (Basel) ; 14(22)2021 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-34832218

RESUMEN

Since the use of the most stable Pb-based materials in the electronic industry has been banned due to human health concerns, numerous research studies have focused on Pb-free materials such as pure tin and its alloys for electronic applications. Pure tin, however, suffers from tin whiskers' formation, which tends to endanger the efficiency of electronic circuits, and even worse, may cause short circuits to the electronic components. This research aims to investigate the effects of stress on tin whiskers' formation and growth and the mitigation method for the immersion of the tin surface's finish deposited on a copper substrate. The coated surface was subjected to external stress by micro-hardness indenters with a 2N load in order to simulate external stress applied to the coating layer, prior to storage in the humidity chamber with environmental conditions of 30 °C/60% RH up to 52 weeks. A nickel underlayer was deposited between the tin surface finish and copper substrate to mitigate the formation and growth of tin whiskers. FESEM was used to observe the whiskers and EDX was used for measuring the chemical composition of the surface finish, tin whiskers, and oxides formed after a certain period of storage. An image analyzer was used to measure the whiskers' length using the JEDEC Standard (JESD22-A121A). The results showed that the tin whiskers increased directly proportional to the storage time, and they formed and grew longer on the thicker tin coating (2.3 µm) than the thin coating (1.5 µm). This is due to greater internal stress being generated by the thicker intermetallic compounds identified as the Cu5Sn6 phase, formed on a thicker tin coating. In addition, the formation and growth of CuO flowers on the 1.5 µm-thick tin coating suppressed the growth of tin whiskers. However, the addition of external stress by an indentation on the tin coating surface showed that the tin whiskers' growth discontinued after week 4 in the indented area. Instead, the whiskers that formed were greater and longer at a distance farther from the indented area due to Sn atom migration from a high stress concentration to a lower stress concentration. Nonetheless, the length of the whisker for the indented surface was shorter than the non-indented surface because the whiskers' growth was suppressed by the formation of CuO flowers. On the other hand, a nickel underlayer successfully mitigated the formation of tin whiskers upon the immersion of a tin surface finish.

4.
Materials (Basel) ; 11(10)2018 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-30248935

RESUMEN

The coating is one of the biggest problems in the recycling of coated multicomponent hardmetal scraps. The isothermal oxidation behavior of WC-Co multicomponent cemented carbide inserts with a TiCN/Al2O3/TiN hard coating in the recycling process was investigated. The oxidation rate slowed down as the protective coating blocked element diffusion. A rapid oxidation rate was obtained when they were milled into powders and isothermally oxidized at 900 °C. A rapid path for element diffusion was provided by the defects, which were promoted by stress, expansion, and gas volatilization. Both the TiN and TiCN layers were oxidized to a porous TiO2 scale, while the Al2O3 phase remained and the dense Al2O3 layer acted as a barrier for its good oxidation resistance. Pieces of the Al2O3 layer were obviously seen in the final oxides. This provides critical information to reduce the negative effect of coatings and improve the performance of recycled WC powders and hard alloys.

5.
Mater Sci Eng C Mater Biol Appl ; 71: 520-528, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-27987740

RESUMEN

In order to solve wear resistance of Ti alloy biomaterials, the concept of a graded nano-TiN coating has been proposed. The coating was prepared on Ti-6Al-4V bio-alloy by DC reactive magnetron sputtering. The wear performance of the coated specimens was measured in Hank's solution under the load of 10N, and the biocompatibility was evaluated according to ISO-10993-4 standard. The results show that the gradient coating exhibits a gradual change in compositions and microstructures along the direction of film growth. Nano-TiN with the size of several to dozens nanometers and Ti4N3-x transitional phase with variable composition form a graded composite structure, which significantly improves adhesion strength (Lc1=80N, Lc2=120N), hardness (21GPa) and anti-wear performance (6.2×10-7mm3/Nm). The excellent bonding and wear resistance result from a good match of mechanical properties at substrate/coating interface and the strengthening and toughening effects of the nanocrystalline composite. The nano-TiN coating has also been proved to have good biocompatibility through in-vitro cytotoxicity, hemocompatibility and general toxicity tests. And thus, the proposed graded nano-TiN coating is a good candidate improving wear resistance of many implant medical devices.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Fricción , Titanio/química , Aleaciones
6.
Mater Sci Eng C Mater Biol Appl ; 33(7): 4337-42, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23910351

RESUMEN

In this study, formation of magnesium substituted hydroxyapatite (Ca10-xMgx(PO4)6(OH)2) on (Ti,Mg)N and TiN coating surfaces were investigated. The (Ti1-x,Mgx)N (x=0.064) coatings were deposited on titanium substrates by using cathodic arc physical vapor deposition technique. TiN coated grade 2 titanium substrates were used as reference to understand the role of magnesium on hydroxyapatite (HA) formation. The HA formation experiments was carried out in simulated body fluids (SBF) with three different concentrations (1X SBF, 5X SBF and 5X SBF without magnesium ions) at 37 °C. The coatings and hydroxyapatite films formed were characterized by scanning electron microscope (SEM), X-ray diffraction (XRD) and FTIR Spectroscopy techniques. The energy dispersive X-ray spectroscopy (EDS) analyses and XRD investigations of the coatings indicated that magnesium was incorporated in the TiN structure rather than forming a separate phase. The comparison between the TiN and (Ti, Mg)N coatings showed that the presence of magnesium in TiN structure facilitated magnesium substituted HA formation on the surface. The (Ti,Mg)N coatings can potentially be used to accelerate the HA formation in vivo conditions without any prior hydroxyapatite coating procedure.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Durapatita/química , Compuestos de Magnesio/química , Magnesio/química , Ensayo de Materiales/métodos , Compuestos de Nitrógeno/química , Titanio/química , Líquidos Corporales/química , Electrodos , Humanos , Microscopía Electrónica de Rastreo , Espectroscopía Infrarroja por Transformada de Fourier , Difracción de Rayos X
7.
Mater Sci Eng C Mater Biol Appl ; 33(3): 1355-60, 2013 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-23827582

RESUMEN

Atrial septal defect (ASD) occlusion devices made of nickel-titanium (NiTi) have a major shortcoming in that they release nickel into the body. We modified NiTi occluders using Arc Ion Plating technology. Nano lamellar titanium-nitrogen (TiN) coatings were formed on the surfaces of the occluders. The safety and efficacy of the modified NiTi occluders were evaluated in animal model. The results showed that 38 out of 39 rams (97%) survived at the end of the experiment. Fibrous capsules formed on the surfaces of the devices. Gradual endothelialization took place through the attachment of endothelial progenitor cells from the blood and the migration of endothelial cells from adjacent endocardium. The neo-endocardium formed more quickly in the coated group than in the uncoated group, as indicated by the evaluation of the six month study group. After TiN coating, there was no significant difference in endothelial cell cycle. TiN coating significantly reduced the release of nickel in both in vivo and in vitro indicating an improved biocompatibility of the nitinol ASD occluders. Superior and modified ASD occluders may provide a good choice for people with nickel allergies after sFDA registration, which is expected in one to two years.


Asunto(s)
Aleaciones/efectos adversos , Materiales Biocompatibles Revestidos/efectos adversos , Defectos del Tabique Interatrial/terapia , Nanoestructuras/efectos adversos , Níquel/efectos adversos , Dispositivo Oclusor Septal , Titanio/efectos adversos , Animales , Ciclo Celular , Endocardio/metabolismo , Endocardio/patología , Endocardio/ultraestructura , Células Endoteliales/metabolismo , Células Endoteliales/patología , Defectos del Tabique Interatrial/sangre , Implantes Experimentales , Masculino , Nanoestructuras/ultraestructura , Níquel/sangre , Implantación de Prótesis , Ovinos , Resultado del Tratamiento
8.
J Adv Prosthodont ; 1(2): 102-6, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21165263

RESUMEN

STATEMENT OF PROBLEM: Screw loosening has been a common complication and still reported frequently. PURPOSE: The purpose of this study was to evaluate abrasion of the implant fixture and TiN coated abutment screw after repeated delivery and removal with universal measuring microscope. MATERIAL AND METHODS: Implant systems used for this study were Osstem and 3i. Seven pairs of implant fixtures, abutments and abutment screws for each system were selected and all the fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. After 20 times of repeated closing and opening test, the evaluation for the change of inner surface of implant and TiN-coated abutment screw, and weight loss were measured. Mann-Whitney test with SPSS statistical software for Window was applied to analyze the measurement of weight loss. RESULTS: TiN-coated abutment screws of Osstem and 3i showed lesser loss of weight than non-coated those of Osstem and 3i (P < .05, Mann-Whitney test). CONCLUSION: Conclusively, TiN coating of abutment screw showed better resistance to abrasion than titanium abutment screw. It was concluded that TiN coating of abutment screw would reduce the loss of preload with good abrasion resistance and low coefficient of friction, and help to maintain screw joint stability.

9.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-107293

RESUMEN

STATEMENT OF PROBLEM: Screw loosening has been a common complication and still reported frequently. PURPOSE: The purpose of this study was to evaluate abrasion of the implant fixture and TiN coated abutment screw after repeated delivery and removal with universal measuring microscope. MATERIAL AND METHODS: Implant systems used for this study were Osstem and 3i. Seven pairs of implant fixtures, abutments and abutment screws for each system were selected and all the fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. After 20 times of repeated closing and opening test, the evaluation for the change of inner surface of implant and TiN-coated abutment screw, and weight loss were measured. Mann-Whitney test with SPSS statistical software for Window was applied to analyze the measurement of weight loss. RESULTS: TiN-coated abutment screws of Osstem and 3i showed lesser loss of weight than non-coated those of Osstem and 3i (P < .05, Mann-Whitney test). CONCLUSION: Conclusively, TiN coating of abutment screw showed better resistance to abrasion than titanium abutment screw. It was concluded that TiN coating of abutment screw would reduce the loss of preload with good abrasion resistance and low coefficient of friction, and help to maintain screw joint stability.


Asunto(s)
Colodión , Fricción , Articulaciones , Estaño , Titanio , Pérdida de Peso
10.
Sensors (Basel) ; 8(11): 6984-6998, 2008 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-27873912

RESUMEN

Hard coatings such as titanium nitride (TiN) and chromium nitride (CrN) are widely used in cutting and forming tools against wear and corrosion. In the present study, hard coating films were deposited onto AISI 1070 steels by a cathodic arc evaporation plating (CAVP) technique. These samples were subjected to wear in a conventional lathe for investigating the tribological behaviour of coating structure, and prenitrided subsurface composition was characterized using scanning electron microscopy (SEM), line scan analyses and X-ray diffraction (XRD). The wear properties of TiN- and CrNcoated samples were determined using an on-line monitoring system. The results show that TiN-coated samples demonstrate higher wear resistance than CrN-coated samples.

11.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-25863

RESUMEN

PURPOSE: The aim of this study is to evaluate the effect of TiN coating of abutment screw on the unscrewing torque. MATERIAL AND METHODS: Titanium and Gold-Tite abutment screws were classified into two groups, Group A and C respectively, as control groups. Titanium abutment screws with TiN coatings were also classified into two groups, Group B and D, as experimental ones. Group A and B were tightened to 20 Ncm input torque, and Group C and D were tightened to 32 Ncm torque. Detorque values were measured with digital torque gauge during repeated closing and opening experiment. RESULTS: Abutment screws with TiN coating (Group B and D) showed statistically significant higher mean detorque values than those of Group A and C. DISSCUSION: Physical properties of TiN coating, such as low friction coefficient, high hardness and wear resistance, might contribute to higher detorque values. CONCLUSION: It is suggested that TiN coating of abutment screw help to reduce the risk of screw loosening and improve the stability of screw joint.


Asunto(s)
Fricción , Dureza , Articulaciones , Estaño , Titanio , Torque
12.
Artículo en Coreano | WPRIM (Pacífico Occidental) | ID: wpr-179761

RESUMEN

STATEMENT OF PROBLEM: The adhesion between titanium and ceramic is less optimal than conventional metal-ceramic bonding, due to reaction layer form on cast titanium surface during porcelain firing. PURPOSE: This study characterized the effect of titanium-ceramic adhesion after gold and TiN coating on cast and wrought titanium substrates. MATERIAL AND METHOD: Six groups of ASTM grade II commercially pure titanium and cast titanium specimens(13mm x 13mm x 1mm) were prepared(n=8). The conventional Au-Pd-In alloy served as the control. All specimens were sandblasted with 110micrometer Al2O3 particles and ultrasonically cleaned for 5min in deionized water, and dried in air before porcelain firing. An ultra-low-fusing dental porcelain(Vita Titankeramik) was fused on titanium surfaces. Porcelain was debonded by a biaxial flexure test at a cross head speed of 0.25mm/min. The excellent titanium-ceramic adherence was exhibited by the presence of a dentin porcelain layer on the specimen surface after the biaxial flexure test. Area fraction of adherent porcelain(AFAP) was determined by SEM/EDS. Numerical results were statistically analyzed by one-way ANOVA and Student- Newman-Keuls test at alpha=0.05. RESULTS: The AFAP value of cast titanium was greatest in the group 2 with TiN coating, followed by group 1 with Au coating and the group 3 with Al2O3 sandblasting. Significant statistical difference was found between the group 1, 2 and the group 3 (p.05). The AFAP values of the cast titanium and the wrought titanium were similar. However the group treated with Al2O3 sandblasting showed significantly lower value (p<.05).


Asunto(s)
Aleaciones , Cerámica , Porcelana Dental , Dentina , Incendios , Cabeza , Estaño , Titanio , Agua
13.
Artículo en Coreano | WPRIM (Pacífico Occidental) | ID: wpr-218244

RESUMEN

STATEMENT OF PROBLEM: A few dry lubricants were applied to abutment screws for the improvement of joint stability. PURPOSE: The purpose of this study was to evaluate the surface change and fit of TiNCoated abutment screw through the examination of tested screws in the field emission scanning electron microscope(FE-SEM;Netherland, Phillips co., model:XL 30 SFEG) after repeated closing and opening. MATERIALS AND METHOD: Titanium(3i/implant Innovations Inc, USA) and Gold-Tite abutment screws(3i/implant Innovations Inc, USA) were selected for Group A and C respectively. TiN coated titanium abutment screws were also divided into two groups, Group B and D. Abutment screws of each group and the fit of abutment screw/implant fixture/abutment were observed on FE-SEM after repeated closing and opening test respectively. RESULTS: 1. The abutment screws of TiN coated groups(Group B and D) showed more remarkable wear resistance in the threads of the screw than those of the other group(Group A and C). 2. There were more severe wear and defect of TiN coating in Group D tightened to 32 Ncm than Group B to 20 Ncm. 3. There was no difference in the fit of abutment screw/fixture/abutment among four groups, Group A, Group B, Group C and Group D. CONCLUSION: Under the conditions of this study, it is suggested that TiN coating of abutment screw be clinically acceptable and be expected to reduce the risk of abutment screw loosening. TiN coating of abutment screw showed good resistance against wear and the adequate fit of abutment screw/implant fixture/abutment.


Asunto(s)
Articulaciones , Lubricantes , Estaño , Titanio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA