Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Heart Vessels ; 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38806839

RESUMEN

Hypertrophic cardiomyopathy (HCM) patients with sarcomere mutations have an increased risk of heart failure and left ventricular (LV) systolic dysfunction. We hypothesize that sarcomere mutation carriers have abnormal myocardial contractility before LV dysfunction. Therefore, we aimed to associate myocardial contractility with identified sarcomere mutations and predict genotyped HCM patients with sarcomere mutation by three-dimensional speckle tracking imaging (3D-STI). A retrospective analysis of 117 HCM patients identified 32 genotype-positive (G +) and 85 genotype-negative (G-) patients. Genotype-positive patients had higher globe circumferential strain (GCS), globe longitudinal strain (GLS), and globe radial strain (GRS) (p < 0.05), and multivariate logistic regression revealed that these variables were associated with a positive genetic status (p < 0.05). After the propensity matches other possible influencing factors, we developed three models, named Model GCS, Model GLS, and Model GRS, which could identified genotype-positive HCM patients with excellent performance (AUC of 0.855, 0.833, and 0.870 respectively, all p < 0.001). Genotype-positive HCM patients show a higher myocardial hyper-contractility status than patients without sarcomere mutations. When combined with clinical and echocardiographic markers, the 3D-STI parameters can effectively identify the likelihood of genotype-positive HCM.

2.
Cardiorenal Med ; 13(1): 248-258, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37586345

RESUMEN

INTRODUCTION: Although maintenance hemodialysis (MHD) in end-stage renal disease (ESRD) appears to induce some risk factors and strengthen cardiac function, the morbidity of ESRD patients receiving hemodialysis remains high. This study aimed to identify left ventricular (LV) structural and functional abnormalities in ESRD patients on MHD using three-dimensional speckle-tracking imaging (3D-STI). METHODS: Eighty-five ESRD patients with normal LV ejection fraction (LVEF >50%) participated in this study, including 55 MHD patients comprising the chronic kidney disease (CKD) V-D group and 30 nondialysis patients comprising the CKD V-ND group. Thirty age- and sex-matched control participants who had normal kidney function were enrolled as the N group. Conventional echocardiography and 3D-STI were conducted, and global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS), and global radial strain (GRS) values were measured. RESULTS: No substantial differences in two-dimensional LVEF were observed among the three groups, and LV hypertrophy was the most common abnormality in patients with ESRD, irrespective of whether they had received or not received MHD. There were no significant differences in the 3D LV mass index between the CKD V-ND and N groups (p > 0.05). Conversely, the 3D LV mass index was considerably higher in the CKD V-D group than in both the N and CKD V-ND groups. The GLS, GAS, and GRS values were significantly lower in the CKD V-ND group than in the N group (p < 0.05). Furthermore, the CKD V-D group had significantly lower GLS, GCS, GAS, and GRS values than the N and CKD V-ND groups (p < 0.05). The interventricular septal thickness and E/e' ratio were independently associated with LV strain values in all patients with ESRD. CONCLUSIONS: MHD can exacerbate LV deformation and dysfunction in ESRD patients with preserved LVEF, and 3D-STI can be potentially useful for detecting these asymptomatic preclinical abnormalities.


Asunto(s)
Ecocardiografía Tridimensional , Fallo Renal Crónico , Disfunción Ventricular Izquierda , Humanos , Función Ventricular Izquierda , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/diagnóstico por imagen , Ecocardiografía Tridimensional/efectos adversos , Ecocardiografía Tridimensional/métodos , Diálisis Renal/efectos adversos , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/terapia
3.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1027130

RESUMEN

Objective:To explore the characteristics of echocardiographic parameters among the many parameters of two-dimensional transthoracic echocardiography(2D-TTE) and three-dimensional speckle tracking imaging (3D-STI) that can be used for early identification of familial hypertrophic cardiomyopathy(FHCM) mutation gene carriers, and construct a Nomogram prediction model, in order to provide a diagnostic method for early identification of G+ P- patients for clinical practice.Methods:A total of 15 FHCM families admitted to the General Hospital of Ningxia Medical University from November 2017 to August 2022 were enrolled.Whole exome sequencing and Sanger sequencing technology were used for gene detection, among which 54 were G+ P- and 75 were G-P-. Stratified random sampling was used to divide the subjects into training set ( n=90) and test set ( n=39) according to the ratio of 7∶3. Philips iE33 ultrasonic diagnostic instrument and TomTec offline software were used to obtain relevant ultrasonic parameters. Lasso regression and Logistic regression were used to screen echocardiographic parameters and obtain independent risk factors for early prediction of G+ P-, based on which a Nomogram prediction model was established. Results:①Lasso-Logistic regression showed that global longitudinal strain(GLS) ( OR=1.739, 95% CI=1.305-2.316) and left ventricular outflow trac velocity time integral(LVOT-VTI) ( OR=1.358, 95% CI=1.072-1.722) could be used as independent risk factors for early prediction of G+ P-. ②The Nomogram prediction model was established based on the above indicators. After 1000 internal verifications of Bootstrap self-sampling, the C-indices of the training set and the test set were 0.885 (95% CI=0.816-0.954), 0.878 (95% CI=0.764-0.992), which had good internal consistency. ③The results of the calibration curve showed that the risk of G+ P- predicted by the Nomogram model was basically consistent with the actual risk (training set P=0.990, test set P=0.961); the clinical decision curve shows that under different threshold probabilities, using this prediction model to provide patients with clinical decision-making could bring benefits to patients. Conclusions:Echocardiographic parameters GLS and LVOT-VTI can be used as independent risk factors to predict FHCM mutation gene carriers. The Nomogram prediction model has good discrimination, goodness of fit and clinical benefit in identifying whether the family members of FHCM patients carry the mutation gene, and it can provide a new idea and evaluation method for the early identification of FHCM mutation gene carriers by echocardiography.

4.
Zhongguo Dang Dai Er Ke Za Zhi ; 24(5): 566-571, 2022 May 15.
Artículo en Chino | MEDLINE | ID: mdl-35644198

RESUMEN

OBJECTIVES: To study the application of three-dimensional speckle-tracking imaging in evaluating left ventricular systolic function and its correlation with peripheral arterial elasticity in children with simple obesity. METHODS: Random sampling combined with convenience sampling was used to obtain research samples, and then the samples were divided into an obesity group (23 cases), an overweight group (21 cases), and a normal group (24 cases). Three-dimensional speckle-tracking imaging was used to measure the global longitudinal strain (GLS), global radial strain (GRS), and global circumferential strain (GCS) of the left ventricle. An automatic arteriosclerosis tester was used to measure ankle-brachial index (ABI) and brachial-ankle pulse wave velocity (baPWV). These parameters were compared among the three groups. The correlation of three-dimensional speckle-tracking parameters with ABI and baPWV was evaluated. RESULTS: There were no significant differences in GLS, GRS, and GCS between the obesity and normal groups (P>0.05). The overweight group had a significantly higher GLS than the normal group [(-24±7) vs (-19±12), P<0.05]. The obesity and overweight groups had a significantly lower ABI than the normal group [(1.00±0.09)/(1.09±0.13) vs (2.25±0.13), P<0.05). The obesity group had a significantly higher baPWV than the normal group [(978±109) vs (905±22), P<0.05]. In the children with obesity, GLS was positively correlated with baPWV (r=0.516, P<0.05) , but not correlated with ABI (P>0.05), and GCS and GRS had no significant correlation with ABI or baPWV (P>0.05). CONCLUSIONS: There are varying degrees of changes in left ventricular systolic function and peripheral arterial elasticity in children with simple obesity, and there is a certain correlation between them.


Asunto(s)
Ecocardiografía Tridimensional , Sobrepeso , Índice Tobillo Braquial , Niño , Ecocardiografía Tridimensional/métodos , Elasticidad , Humanos , Obesidad , Estudios Prospectivos , Análisis de la Onda del Pulso
5.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-928644

RESUMEN

OBJECTIVES@#To study the application of three-dimensional speckle-tracking imaging in evaluating left ventricular systolic function and its correlation with peripheral arterial elasticity in children with simple obesity.@*METHODS@#Random sampling combined with convenience sampling was used to obtain research samples, and then the samples were divided into an obesity group (23 cases), an overweight group (21 cases), and a normal group (24 cases). Three-dimensional speckle-tracking imaging was used to measure the global longitudinal strain (GLS), global radial strain (GRS), and global circumferential strain (GCS) of the left ventricle. An automatic arteriosclerosis tester was used to measure ankle-brachial index (ABI) and brachial-ankle pulse wave velocity (baPWV). These parameters were compared among the three groups. The correlation of three-dimensional speckle-tracking parameters with ABI and baPWV was evaluated.@*RESULTS@#There were no significant differences in GLS, GRS, and GCS between the obesity and normal groups (P>0.05). The overweight group had a significantly higher GLS than the normal group [(-24±7) vs (-19±12), P<0.05]. The obesity and overweight groups had a significantly lower ABI than the normal group [(1.00±0.09)/(1.09±0.13) vs (2.25±0.13), P<0.05). The obesity group had a significantly higher baPWV than the normal group [(978±109) vs (905±22), P<0.05]. In the children with obesity, GLS was positively correlated with baPWV (r=0.516, P<0.05) , but not correlated with ABI (P>0.05), and GCS and GRS had no significant correlation with ABI or baPWV (P>0.05).@*CONCLUSIONS@#There are varying degrees of changes in left ventricular systolic function and peripheral arterial elasticity in children with simple obesity, and there is a certain correlation between them.


Asunto(s)
Niño , Humanos , Índice Tobillo Braquial , Ecocardiografía Tridimensional/métodos , Elasticidad , Obesidad , Sobrepeso , Estudios Prospectivos , Análisis de la Onda del Pulso
6.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-932400

RESUMEN

Objective:To evaluate the left ventricular myocardial strain in patients with light chain cardiac amyloidosis (AL-CA) with normal left ventricular ejection fraction (LVEF) by three-dimensional speckle tracking imaging(3D-STI), and to explore the clinical value of 3D-STI in predicting the prognosis of AL-CA patients with normal LVEF.Methods:A total of 80 patients with AL-CA and LVEF≥50% were retrospectively analyzed in the Xijing Hospital of Air Force Military Medical University from October 2014 to May 2020.According to whether the patients had endpoint events, they were divided into endpoint event group and non-endpoint event group. The clinical data, conventional echocardiographic parameters, 3D-STI related parameters and follow-up results were collected. Cox regression proportional hazards model was used to analyze the survival status of AL-CA patients with univariate and multivariate regression analyses, in order to find the relevant indicators of conventional echocardiography and 3D-STI to predict adverse events.Results:All patients were followed up for 20(7.3, 40.8) months. At the end of follow-up, 25 patients had all-cause deaths. Compared with the non-endpoint group, the endpoint event group had significantly increased left ventricular end diastolic maximum wall thickness (MLVWT), peak early diastolic flow velocity/peak early diastolic velocity at mitral annulus(E/e′) (all P<0.05), and decreased LVEF, left ventricular global longitudinal strain (GLS) and basal segment longitudinal strain (LS) (all P<0.05). Multivariate cox regression analysis after adjusting for age and gender showed that basal segment LS ( HR=0.812, 95% CI=0.675-0.976, P=0.026) was an independent predictor of end-point events in patients with AL-CA. Kaplan-Meier survival curve showed that AL-CA patients with basal segment LS≤13.07% were more likely to have endpoint events. Conclusions:Basal segment LS can be used as a predictor of endpoint events in patients with AL-CA.

7.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-956645

RESUMEN

Objective:To assess the left ventricular(LV) structure and systolic function in amateur marathon runners using real-time three-dimensional speckle tracking echocardiography(3D-STE) and analyze its correlation with the running volume.Methods:A total of 84 amateur marathon runners were recruited between January 2019 and October 2021 in Hangzhou and were divided into short-term (ST) group(≤6 months) and more extended-term(MET) group(>6 months–2 years) based on their time of participating in the marathon. Thirty-nine healthy volunteers were enrolled from the Affiliated Hospital of Hangzhou Normal University during the same period as a control group. The running volume of ST and MET runners were recorded, LV end-diastolic volume(EDV), end-systolic volume(ESV), LV mass(LVM), LV ejection fraction(LVEF), LV global longitudinal strain(GLS), global circumferential strain(GCS), global radial strain(GRS), global area strain (GAS), twist, and torsion were measured by conventional echocardiography and 3D-STE. The differences of those parameters among the three groups were compared. The correlation between 3D-STE parameters and the running volume was further analyzed.Results:In ST amateur marathon runners, LV EDV was higher compared with controls( P<0.05). Compared with ST and control groups, LV EDV, ESV, and LVM of MET runners were increased(all P<0.05). In addition, compared with control group, GLS of MET runners was increased( P<0.05). The LVEF, GCS, GRS, GAS, twist, and torsion showed no statistically significant differences among the three groups(all P>0.05). In amateur marathon runners LV EDV, ESV, LVM had statistically significant positive correlations with an average weekly running volume and total running volume (all P<0.01). Multivariate linear regression analysis showed that the total running volume was an independent correlation factor in LV EDV of amateur marathon runners (β=0.618, P<0.01). Conclusions:Amateur marathon runners participating in a short term marathon mainly show an increase in LV EDV, the longitudinal systolic function of the LV can be enhanced in the early stage of the marathon.

8.
Artículo en Chino | MEDLINE | ID: mdl-34488266

RESUMEN

Objective: To evaluate the changes of right ventricular function in patients with pneumoconiosis in different stages using three-dimensional speckle-tracking imaging (3D-STI) . Methods: In June 2020, 114 pneumoconiosis patients were selected as subjects, including 45 patients in stage Ⅰ pneumoconiosis group, 36 patients in stage Ⅱ pneumoconiosis group and 33 patients in stage Ⅲ pneumoconiosis group. Fifty healthy subjects were enrolled and served as control group. The longitudinal strain (LS) , radial strain (RS) and circumferential strain (CS) of free wall middle and basal segment of right ventricular were collected and compared. The right ventricular global longitudinal strain (GLS) , right ventricular global circumferential strain (GCS) , right ventricular ejection fraction (RVEF) , right ventricular global radial strain (GRS) , the rate of fractional area change (FAC) , the tricuspid valve systolic peak velocity (TVSPV) and the pulmonary artery systolic pressure (PASP) of each subject in the groups were collected and compared by 3D-STI. Results: The LS and RS of the right ventricular basal segment of patients in stage Ⅱ pneumoconiosis group were significantly lower than those of control group (P<0.0125) . The LS, CS, RS of the right ventricular basal segment and RS of right ventricular middle segment of patients in stage Ⅲ pneumoconiosis group were significantly lower than those of control group (P<0.0125) . The LS, CS and RS of the right ventricular basal segment of patients in stage Ⅰ pneumoconiosis group were significantly higher than those of stage Ⅲ pneumoconiosis group (P<0.0125) , and the RS of the right ventricular basal segment of patients in stage Ⅱ pneumoconiosis group was significantly higher than that of stage Ⅲ pneumoconiosis group (P<0.0125) . The levels of RVEF and GLS of patients in stage Ⅱ and stage Ⅲ pneumoconiosis group were significantly lower than those of control group (P<0.0125) , while the levels of PASP were significantly higher than that of control group (P<0.0125) . The levels of FAC and TVSPV of patients in stage Ⅲ pneumoconiosis group were significantly lower than those of control group (P<0.0125) . The levels of RVEF, GLS and FAC of patients in stage Ⅰ pneumoconiosis group were significantly higher those that of stage Ⅲ pneumoconiosis group (P<0.0125) , and the PASP level was significantly lower than that of stage Ⅲ pneumoconiosis group (P<0.0125) . The FAC level of patients in stage Ⅱ pneumoconiosis group was significantly higher than that of stage Ⅲ pneumoconiosis group (P<0.0125) . Conclusion: Patients with pneumoconiosis could experience a decline in right ventricular function at an early stage. The 3D-STI can accurately detect the GLS, GRS, GCS and hemodynamic changes of the right ventricular and evaluate the right ventricular function comprehensively and objectively. 3D-STI is of great significance for the early detection of right ventricular dysfunction in patients with pneumoconiosis.


Asunto(s)
Neumoconiosis , Disfunción Ventricular Derecha , Humanos , Reproducibilidad de los Resultados , Volumen Sistólico , Sístole , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha
9.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 46(4): 379-384, 2021 Apr 28.
Artículo en Inglés, Chino | MEDLINE | ID: mdl-33967084

RESUMEN

OBJECTIVES: To compare the left ventricular systolic function between the 1eft bundle branch pacing (LBBP) and right ventricular septum pacing (RVSP) in patients with pacemaker dependence by three-dimensional speckle tracking imaging (3D-STI). METHODS: A total of 65 patients with atrioventricular block (AVB) (Mobitz type II second-degree AVB, high-degree AVB, or third-degree AVB), who underwent permanent cardiac pacing implantation including 32 patients receiving LBBP (LBBP group) and 33 patients receiving RVSP (RVSP group) from June 2018 to June 2019,were enrolled in this study. These patients met the following inclusion criterion: pre-operative left ventricular ejection fraction (LVEF)>50% and ventricular pacing rate>40% at 6-month programming follow-up; and the patients underwent echocardiography at pre-operation and 6 months after operation. The 3D-STI was used to obtain global longitudinal strain (GLS), global circumferential strain (GCS), global radial strain (GRS), and global area strain (GAS). RESULTS: All the patients in the LBBP group and the RVSP group had normal LVEF, there was no significant difference between the 2 group (P>0.05). The LVEF was slightly decreased at 6-month follow-up in the RVSP group, but there was no significant change compared with pre-operation (P>0.05). There were no significant difference in LVEF, GLS, GCS, GRS and GAS at pre-operation and 6-month after operation between the LBBP group and the RVSP group (all P>0.05). Compared with pre-operation, the GLS and GCS were significantly decreased in the LBBP group; while the GLS, GCS, GRS and GAS in the RVSP group were also significantly decreased at 6-month follow-up (all P<0.05). CONCLUSIONS: For patients with pacemaker dependence and normal LVEF at pre-operation, the cardiac function in the LBBP group is not significantly better than that in the RVSP group in short term follow-up. But in terms of physiologic pacing and long-term cardiac function protection, the 1eft bundle branch pacing is an optimal pacing mode.


Asunto(s)
Marcapaso Artificial , Tabique Interventricular , Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Humanos , Volumen Sistólico , Función Ventricular Izquierda , Tabique Interventricular/diagnóstico por imagen
10.
J Clin Ultrasound ; 49(4): 378-384, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33372283

RESUMEN

OBJECTIVE: To investigate the clinical value of three-dimensional speckle tracking imaging (3D-STI) in evaluating left ventricular (LV) systolic function in patients with ovarian cancer (OC) treated with paclitaxel and carboplatin. METHOD: We studied 30 patients with OC treated with paclitaxel combined with carboplatin chemotherapy. Two-dimensional echocardiography and 3D-STI were performed in the patients before they underwent 2- and 6-cycle chemotherapies, and in 30 normal control subjects. Were measured LV end-diastolic volume (EDV), end-systolic volume (ESV), three-dimensional LV ejection fraction (3D-LVEF), stroke volume (SV), spherical index (SPI), LV end-diastolic mass (LV EDmass), LV end-systolic mass (LV ESmass), LV global longitudinal strain (GLS), global circumferential strain (GCS), global radial strain (GRS), global area strain (GAS) and cardiac troponin T(cTnT). At the end of chemotherapy, magnetic resonance imaging (MRI) was also performed. RESULT: The 3D conventional strain values (3D-LVEF, SV, LV EDV) after the 2- and 6-cycle chemotherapy were lower than before chemotherapy. LV Edmass, LV ESmass and cTnT were higher while LV GLS, GCS, GRS, GAS were lower after 2- and after 6-cycle chemotherapy than before chemotherapy. There was no significant difference in ESV and EDV between the 3D-STI and MRI parameters. GAS showed a significant negative correlation with cTnT. MRI and 3D-STI variables were significantly correlated, and the receiver operating characteristic curves showed the greater area under the curve for GAS after 2- and after 6-cycle chemotherapy. After 2-cycle chemotherapy, the highest specificity for GAS was 93.3%, and the highest sensitivity for GLS was 70.0%. After 6-cycle chemotherapy, the highest specificity for GAS was 96.7%, and the highest sensitivity for GLS was 96.7%. CONCLUSION: The LV systolic function decreased in OC patients treated with paclitaxel and carboplatin, showing that 3D-STI may detect early LV systolic dysfunction.


Asunto(s)
Carcinoma Epitelial de Ovario/tratamiento farmacológico , Ecocardiografía Tridimensional/métodos , Corazón/efectos de los fármacos , Neoplasias Ováricas/tratamiento farmacológico , Carboplatino/administración & dosificación , Carcinoma Epitelial de Ovario/fisiopatología , Estudios de Casos y Controles , Ecocardiografía , Femenino , Corazón/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/efectos de los fármacos , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Neoplasias Ováricas/fisiopatología , Paclitaxel/administración & dosificación , Curva ROC , Volumen Sistólico/efectos de los fármacos , Función Ventricular Izquierda/efectos de los fármacos
11.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-880670

RESUMEN

OBJECTIVES@#To compare the left ventricular systolic function between the 1eft bundle branch pacing (LBBP) and right ventricular septum pacing (RVSP) in patients with pacemaker dependence by three-dimensional speckle tracking imaging (3D-STI).@*METHODS@#A total of 65 patients with atrioventricular block (AVB) (Mobitz type II second-degree AVB, high-degree AVB, or third-degree AVB), who underwent permanent cardiac pacing implantation including 32 patients receiving LBBP (LBBP group) and 33 patients receiving RVSP (RVSP group) from June 2018 to June 2019,were enrolled in this study. These patients met the following inclusion criterion: pre-operative left ventricular ejection fraction (LVEF)>50% and ventricular pacing rate>40% at 6-month programming follow-up; and the patients underwent echocardiography at pre-operation and 6 months after operation. The 3D-STI was used to obtain global longitudinal strain (GLS), global circumferential strain (GCS), global radial strain (GRS), and global area strain (GAS).@*RESULTS@#All the patients in the LBBP group and the RVSP group had normal LVEF, there was no significant difference between the 2 group (@*CONCLUSIONS@#For patients with pacemaker dependence and normal LVEF at pre-operation, the cardiac function in the LBBP group is not significantly better than that in the RVSP group in short term follow-up. But in terms of physiologic pacing and long-term cardiac function protection, the 1eft bundle branch pacing is an optimal pacing mode.


Asunto(s)
Humanos , Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Marcapaso Artificial , Volumen Sistólico , Función Ventricular Izquierda , Tabique Interventricular/diagnóstico por imagen
12.
Organ Transplantation ; (6): 458-2021.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-881531

RESUMEN

Objective To evaluate the application value of three-dimensional speckle tracking imaging (3D-STI) in quantitatively evaluating the left ventricular global strain in recipients within 3 months after renal transplantation. Methods Clinical data including blood pressure, serum creatinine and tacrolimus blood concentration of 34 renal transplant recipients were collected before operation, 7 d, 1 month and 3 months after operation, respectively. Meanwhile, conventional echocardiography and 3D-STI examination were performed. Echocardiographic parameters [left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV) and left ventricular ejection fraction (LVEF)] and 3D-STI parameters [left ventricular global peak longitudinal strain (GPLS), global peak circumferential strain (GPCS), global peak radial strain (GPRS) and global peak area strain (GPAS)] of recipients were collected. The changes of these parameters before operation, 7 d, 1 month and 3 months after operation were statistically compared. The changing characteristic and application value of 3D-STI in quantitatively evaluating the left ventricular global strain in recipients within 3 months after renal transplantation were evaluated. Results LVEF and GPCS did not significantly differ at different time points (all P > 0.05), whereas LVEDV, LVESV, GPLS, GPAS and GPRS significantly differed at different time points from preoperative to within postoperative 3 months (all P < 0.001). GPLS, GPAS and GPRS trended to decline within postoperative 1 month, and slightly increased at 3 months after operation, which was still lower than the preoperative levels. Conclusions Application of 3D-STI may sensitively detect the changes of left ventricular global strain in recipients after renal transplantation when no significant variations are observed in postoperative LVEF. Compared with conventional echocardiography, 3D-STI may more accurately evaluate the changes of left ventricular global strain in recipients after renal transplantation.

13.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-909264

RESUMEN

Objective:To investigate the clinical value of real-time three-dimensional speckle tracking echocardiography in the evaluation of early cardiac function damage in patients with pregnancy induced hypertension.Methods:Sixty-five pregnant women with pregnancy induced hypertension (patient group) and 65 healthy pregnant women (healthy group) who received prenatal examination and delivered between January 2018 and June 2020 in Wenzhou Hospital of Integrated Traditional Chinese and Western Medicine were included in this study. The patient and healthy groups were subjected to routine echocardiography and real-time three-dimensional speckle tracking echocardiography at 24-36 and 32-34 weeks of gestation. The imaging parameters of routine echocardiography and real-time three-dimensional speckle tracking echocardiography measured at different periods of gestation were compared between the two groups.Results:At 24-36 weeks of gestation, there were no significant difference in routine echocardiography parameters of the left ventricle between patient and healthy groups ( t = 0.793-1.748; P = 0.129-0.458). Left ventricular diameter (LVD), intra-ventricular septum diastole (IVSD) and left ventricular posterior wall diameter (LVPWD) in the patient group at 32-34 weeks of gestation were (34.97 ± 2.66) mm, (11.96 ± 1.85) mm, (12.07 ± 1.73) mm, respectively, which were significantly greater than those in the healthy group at the same time [(31.56 ± 2.58) mm, (9.17 ± 1.70) mm, (9.23 ± 1.62) mm] and those in the patient group at 24-36 weeks of gestation [(32.36 ± 2.61) mm, (10.15 ± 1.79) mm, (10.19 ± 1.64) mm, t = 5.437, 6.274, 6.319, 3.621, 4.017, 5.241, all P < 0.001]. Left ventricular ejection fraction (LVEF) in the patient group at 32-34 weeks of gestation was (54.36 ± 4.71)%, which was significantly lower than (63.27 ± 5.04)% in the healthy group at the same time and (59.65 ± 4.62) % in the healthy group at 24-36 weeks of gestation ( t = 7.682, 5.483, both P < 0.001). At 24-36 and 32-34 weeks of gestation, the absolute values of real-time three-dimensional speckle tracking echocardiography parameters left ventricular global longitudinal strain, left ventricular global circumferential strain, left ventricular global radial strain and left ventricular global area strain in the patient group were (23.45 ± 2.58)%, (34.09 ± 3.28)%, (22.03 ± 2.31)%, (34.73 ± 3.58)%, (18.63 ± 2.42)%, (30.74 ± 3.07)%, (19.56 ± 2.28)%, (25.85 ± 3.37)%, respectively, which were significantly lower than those in the healthy group [(26.27 ± 2.74)%, (37.62 ± 3.61)%, (24.67 ± 2.59)%, (39.41 ± 3.96)%, (26.10 ± 2.81)%, (37.56 ± 3.64)%, (24.82 ± 2.59)%, (40.16 ± 3.96)%, t = 4.415, 5.013, 4.724, 6.253, 10.736, 8.592, 7.627, 14.319, all P < 0.001]. In patient group, the absolute values of left ventricular global longitudinal strain, left ventricular global circumferential strain, left ventricular global radial strain and left ventricular global area strain at 32-34 weeks of gestation were (18.63 ± 2.42)%, (30.74 ± 3.07)%, (19.56 ± 2.28)%, (25.85 ± 3.37)%], respectively, which were significantly lower than those at 24-36 weeks of gestation [(23.45 ± 2.58)%, (34.09 ± 3.28)%, (22.03 ± 2.31)% (34.73 ± 3.58)%, t = 7.529, 4.785, 5.194, 8.413, all P < 0.001]. Conclusion:Real-time three-dimensional speckle tracking echocardiography is advantageous in identifying the damage to cardiac function over routine echocardiography. Findings from this study provides a great clinical guiding value for protecting the cardiac function of patients with pregnancy induced hypertension.

14.
Zhonghua Xin Xue Guan Bing Za Zhi ; 48(4): 287-293, 2020 Apr 24.
Artículo en Chino | MEDLINE | ID: mdl-32370479

RESUMEN

Objective: To evaluate the cardiac functional changes in hypertrophic cardiomyopathy(HCM) patients with ß-myosin heavy chain gene (MYH7) mutations by three-dimensional (3D) speckle tracking imaging(3D-STI) and conventional echocardiography modalities, and then to explore the potential predictors of adverse cardiovascular events in these patients. Methods: A consecutive series of 192 HCM patients admitted in our center from October 2014 to October 2016 were genetically screened to identify MYH7 mutations in this retrospective study. A total of 43 HCM patients with MYH7 mutations were enrolled. The patients were divided into events group(n=13) and no event group(n=30) according to the presence or absence of adverse cardiovascular events(primary and secondary endpoints). All patients were followed up to January 2019 after comprehensive evaluation of 3D-STI, two-dimensional and Doppler echocardiography. The adverse cardiovascular events were recorded. Results: The median follow up time was 1 012 (812, 1 330) days. During follow-up, 13 patients (30.2%) reached endpoints: 6 cases of the primary endpoints(2 cases of sudden cardiac death(SCD), 3 cases of survival after defibrillation, and 1 case of appropriate implantable cardioverter-defibrillator(ICD) discharge); 7 cases of the second endpoints(5 cases of heart failure hospitalization, 1 case of syncope and cardioversion due to supraventricular tachycardia, and 1 case of end-stage HCM). Patients with adverse cardiovascular events had higher prevalence of syncope and risk of SCD, enlarged left atrial volume index(LAVI) and reduced 3D left ventricular global longitudinal train (3D-GLS), as compared to those without adverse events(all P<0.05). The multivariate Cox regression analysis showed that reduced 3D-GLS(HR=0.814, 95%CI 0.663-0.999, P=0.049) was an independent predictor for adverse cardiovascular events. The cutoff value of 3D-GLS≤13.67% was linked with significantly increased risk of adverse cardiovascular events in this patient cohort(AUC=0.753, 95%CI 0.558-0.948, sensitivity 86%, specificity 69%, P<0.05). The Kaplan-Meier analysis indicated that the patients with the 3D-GLS≤ 13.67% faced higher risk of death than those with 3D-GLS>13.67%. Conclusion: 3D-GLS is useful on predicting adverse cardiovascular events in HCM patients with MYH7 mutations.


Asunto(s)
Miosinas Cardíacas/genética , Cardiomiopatía Hipertrófica , Cadenas Pesadas de Miosina/genética , Cardiomiopatía Hipertrófica/genética , Ecocardiografía , Humanos , Mutación , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo
15.
Int J Cardiovasc Imaging ; 36(7): 1311-1319, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32277320

RESUMEN

Left ventricular (LV) function undergoes subtle changes (subclinical left ventricular dysfunction) in a large proportion of patients with type 2 diabetes (T2DM) who develop diabetic cardiomyopathy. This study aimed to quantify LV myocardial strain and synchrony in T2DM by real-time three-dimensional echocardiography (RT-3DE), and to evaluate subclinical LV dysfunction in T2DM at different glycemic control levels. Seventy-two patients with T2DM with an LV ejection fraction (LVEF) ≥ 55% and 45 healthy individuals as controls who underwent RT-3DE were studied. Patients were also subdivided into the DMa group (glycosylated hemoglobin < 7%, n = 38) and the DMb group (glycosylated hemoglobin ≥ 7%, n = 34). Three-dimensional strain and synchronization parameters of the left ventricle were measured by RT-3DE and compared among the three groups. Despite a similar LVEF, global longitudinal strain (GLS), global circumferential strain (GCS), and global area strain (GAS) in the DMb group were lower, and the standard deviation of peak time (Tm-SD) and the maximum difference in peak time (Tm-Dif) in the DMb group higher, than those in the control and DMa groups (all p < 0.05). Multivariable linear regression analysis showed that the duration of diabetes was independently associated with GCS (ß = - 0.516, p < 0.001) and GAS (ß = - 0.391, p = 0.005). HbA1c levels were independently associated with GLS (ß = - 0.675, p < 0.001), Tm-SD (ß = 3.363, p < 0.001), and Tm-Dif (ß = 3.895, p < 0.001). RT-3DE can detect subclinical myocardial dysfunction in poor glycemic control of T2DM, and myocardial dysfunction is associated with the duration of diabetes and HbA1c.


Asunto(s)
Diabetes Mellitus Tipo 2/complicaciones , Cardiomiopatías Diabéticas/diagnóstico por imagen , Ecocardiografía Tridimensional , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Adulto , Enfermedades Asintomáticas , Biomarcadores/sangre , Glucemia/metabolismo , Estudios de Casos y Controles , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/diagnóstico , Cardiomiopatías Diabéticas/etiología , Cardiomiopatías Diabéticas/fisiopatología , Femenino , Hemoglobina Glucada/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Riesgo , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología
16.
Chinese Journal of Cardiology ; (12): 287-293, 2020.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-941107

RESUMEN

Objective: To evaluate the cardiac functional changes in hypertrophic cardiomyopathy(HCM) patients with β-myosin heavy chain gene (MYH7) mutations by three-dimensional (3D) speckle tracking imaging(3D-STI) and conventional echocardiography modalities, and then to explore the potential predictors of adverse cardiovascular events in these patients. Methods: A consecutive series of 192 HCM patients admitted in our center from October 2014 to October 2016 were genetically screened to identify MYH7 mutations in this retrospective study. A total of 43 HCM patients with MYH7 mutations were enrolled. The patients were divided into events group(n=13) and no event group(n=30) according to the presence or absence of adverse cardiovascular events(primary and secondary endpoints). All patients were followed up to January 2019 after comprehensive evaluation of 3D-STI, two-dimensional and Doppler echocardiography. The adverse cardiovascular events were recorded. Results: The median follow up time was 1 012 (812, 1 330) days. During follow-up, 13 patients (30.2%) reached endpoints: 6 cases of the primary endpoints(2 cases of sudden cardiac death(SCD), 3 cases of survival after defibrillation, and 1 case of appropriate implantable cardioverter-defibrillator(ICD) discharge); 7 cases of the second endpoints(5 cases of heart failure hospitalization, 1 case of syncope and cardioversion due to supraventricular tachycardia, and 1 case of end-stage HCM). Patients with adverse cardiovascular events had higher prevalence of syncope and risk of SCD, enlarged left atrial volume index(LAVI) and reduced 3D left ventricular global longitudinal train (3D-GLS), as compared to those without adverse events(all P<0.05). The multivariate Cox regression analysis showed that reduced 3D-GLS(HR=0.814, 95%CI 0.663-0.999, P=0.049) was an independent predictor for adverse cardiovascular events. The cutoff value of 3D-GLS≤13.67% was linked with significantly increased risk of adverse cardiovascular events in this patient cohort(AUC=0.753, 95%CI 0.558-0.948, sensitivity 86%, specificity 69%, P<0.05). The Kaplan-Meier analysis indicated that the patients with the 3D-GLS≤ 13.67% faced higher risk of death than those with 3D-GLS>13.67%. Conclusion: 3D-GLS is useful on predicting adverse cardiovascular events in HCM patients with MYH7 mutations.


Asunto(s)
Humanos , Miosinas Cardíacas/genética , Cardiomiopatía Hipertrófica/genética , Ecocardiografía , Mutación , Cadenas Pesadas de Miosina/genética , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo
17.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-799080

RESUMEN

Objective@#To evaluate the left ventricular global systolic function and myocardial fibrosis in adult hypertrophic cardiomyopathy (HCM) patients by three-dimensional speckle tracking echocardiography(3D-STE) combined with cardiac magnetic resonance imaging-late gadolinium enchancemet (CMRI-LGE) sequence, and to explore the association between left ventricular global systolic function and myocardial fibrosis.@*Methods@#Thirty patients with HCM(HCM group) and 33 healthy controls(control group) were enrolled in the study. All patients underwent conventional two-dimensional echocardiography (2DE), tissue Doppler imaging (TDI), and 3D-STE. The following parameters were acquired and compared between the groups: interventricular septal end-diastolic thickness (IVSD), left ventricular posterior wall end-diastolic thickness (LVPWD), left ventricular mass(LVM), left ventricular mass index (LVMI), left atrial volume (LAV), and left ventricular end-systolic volume(LVESV), left ventricular end-diastolic volume (LVEDV), left ventricular outflow tract pressure gradient (LVOT-PG), left ventricular outflow tract velocity time integral (LVOT-VTI), isovolumic relaxation time (IVRT), global strain (GS), global longitudinal strain (GLS), global radial strain (GRS), global circumferential strain (GCS). And 28 patients who met the CMRI indications underwent CMRI-LGE to obtain the LVM, and the correlation and consistency of LVM results obtained from CMRI and 3D-STE were performed.According to LGE results, HCM patients were divided into LGE(+ ) group and LGE (-) group, the differences of GLS, GRS and GCS between the two groups were analyzed.@*Results@#①Compared with the control group, IVSD, LVPWD, LVMI, LAV, LVOT-PG, LVOT-VTI and IVRT were significantly increased in the HCM group (all P<0.05); ②There was no significant difference in GS between the two groups(P>0.05), while GLS and GRS decreased and GCS increased significantly in HCM group (P<0.05); ③The correlation between 3D-STE and CMRI in measuring measured LVM in HCM patients was good, and the results showed good concordance(r=0.807, P<0.01). ④GLS in LGE(+ ) group was lower than in LGE(-) group(P=0.004), but there was no significant difference in GCS and GRS between the two groups(P=0.597, 0.534).@*Conclusions@#①3D-STE can detect the early damage of left ventricular global systolic function in patients with HCM; ②3D-STE combined with CMRI-LGE technology can provide an important imaging reference for the evaluation of the relationship between left ventricular global systolic function and myocardial fibrosis in patients with HCM.

18.
Echocardiography ; 36(8): 1492-1495, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31268561

RESUMEN

OBJECTIVE: To explore the value of three-dimensional speckle-tracking imaging (3DSTI) in detecting left ventricular systolic function in patients with dilated cardiomyopathy (DCM). METHODS: Totally 31 DCM patients were enrolled in this study. Left ventricular end-systolic volume (LVESV), left ventricular end-diastolic volume (LVEDV), and left ventricular ejection fraction (LVEF) were measured using the 3DSTI, two-dimensional echocardiography (2DE), and magnetic resonance imaging (MRI). Left ventricular end-diastolic mass (EDmass) and left ventricular end-diastolic mass index (LVEDmass I) were also detected by 3DSTI and MRI. The differences in these measurements were analyzed and compared. RESULTS: The values of LVESV, LVEDV, and LVEF showed significantly positive correlations among 2DE group, 3DSTI group, and MRI group. The LVEF value showed significant difference among these three groups [(33.3 ± 11.1)%, (30.3 ± 10.6)%, and (26.2 ± 10.7)%; P = 0.04], whereas LVEDV and LVESV values were not significantly different (P > 0.05; respectively). Inter-group comparison showed the mean of LVEF was significantly lower in MRI group than in 2DE group (P = 0.031), whereas there was no significant difference between 2DE group and 3DSTI group and between 3DSTI group and MRI group (P > 0.05; respectively). The EDmass and EDmassI detected by 3DSTI and MRI were (143.2 ± 40.2) g vs (190.0 ± 58.3) g and (83.2 ± 21.1) g/m2 vs (110.1 ± 29.7) g/m2 (P < 0.001; respectively). CONCLUSIONS: The LVEF value detected by 3DSTI is closer to that detected by MRI in DCM patients.


Asunto(s)
Cardiomiopatía Dilatada/diagnóstico , Ecocardiografía Tridimensional/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Adulto , Anciano , Cardiomiopatía Dilatada/fisiopatología , Diástole , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Sístole
19.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-743756

RESUMEN

Objective To evaluate left ventricular (LV) systolic function in patients with paroxysmal atrial fibrillation (PAF) after catheter ablation by three-dimensional speckle tracking imaging (3 D-STI). Methods A total of 35 patients with PAF who underwent catheter ablation were enrolled in this study. The participants underwent standard echocardiography and 3 D-STI three to six months before and after the operation. 30 healthy volunteers were enrolled as controls. 3 D-STI was used to obtain global longitudinal strain (GLS) , global circumferential strain (GCS) , global radial strain (GRS) , and global area strain (GAS). Results The LA and E/e' ratio in PAF group showed no significant difference before and after the operation, but were increased compared with controls.There were no significant differences between PAF group and control group in LV, left ventricular end-diastolic volume (LVEDV) , left ventricular end-systolic volume (LVESV) and left ventricular ejection fraction (LVEF) before and after the operation. Compared with control group, GLS and GAS in PAF group were significantly decreased.GAS in PAF group three to six months after catheter ablation was significantly increased. Conclusions Although with normal LVEF, LV systolic function is impaired in patients with PAF. 3 D-STI technique could sensitively reflet the decline in LV myocardial deformation and systolic function.

20.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-861331

RESUMEN

Objective: To evaluate the impact of acute carbon monoxide poisoning on left ventricular systolic function with three-dimensional speckle tracking imaging (3D-STI). Methods: Totally 109 patients with acute carbon monoxide poisoning (study group) were enrolled and divided into mild (n=36), moderate (n=40) and severe (n=33) subgroups. And 105 healthy volunteers were selected as control group. 3D-STI was performed 1 hour and 1 week after poisoning, respectively. The levels of carboxyhemoglobin (HbCO) and serum cardiac troponin I (cTnI) were measured. The difference and correlation of the indexes were analyzed between the study group and the control group. Results: One hour after acute carbon monoxide poisoning, no significant difference of global longitudinal strain (GLS), global area strain (GAS), global circumferential strain (GCS), global radial strain (GRS) nor left ventricular ejection fraction (LVEF) was found between mild subgroup and control group (all P>0.05), while HbCO and cTnI in mild subgroup were higher than those in control group (both P0.05); GAS in severe subgroup was lower than that in control group (P<0.05), cTnI was higher than that in control group (P<0.05). One hour after acute carbon monoxide poisoning, serum cTnI was negatively correlated with GLS and GAS in the study group (r=-0.626, -0.640, both P<0.05). Conclusion: 3D-STI can early diagnose damage of left ventricular systolic dysfunction caused by acute carbon monoxide poisoning. GAS decreases with the increase of serum cTnI content, which is a good indicator of left ventricular dysfunction in patients with acute carbon monoxide poisoning.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA