Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros











Intervalo de año de publicación
1.
Polymers (Basel) ; 15(23)2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38231999

RESUMEN

In this study, a 3D model of a proton exchange membrane fuel cell (PEMFC) with crossed channels and an ultra-thin membrane is developed to investigate the feasibility of self-humidification; experiments utilizing a PEMFC stack with identical configurations are conducted to validate the simulation results and further investigate the effects of various operating conditions (OCs) on self-humidification. The results indicate that the crossed flow channel leads to enhanced uniformity of water distribution, resulting in improved cell performance under low/no humidification conditions. External humidifiers for the anode can be removed since the performance difference is negligible (≤3%) between RHa = 0% and 100%. Self-humidification can be achieved in the stack at 90 °C or below with an appropriate back pressure among 100-200 kPa. As the current density increases, there is a gradual convergence and crossing of the voltage at low RH with that at high RH, and the crossover points are observed at 60-80 °C with suitable pressure when successful self-humidification is achieved. Below the current density of the point, the stack's performance is inferior at lower RH due to membrane unsaturation, and conversely, the performance is inferior at higher RH due to flooding; this current density decreases with higher pressure and lower temperature.

2.
ACS Appl Mater Interfaces ; 14(50): 56226-56236, 2022 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-36484483

RESUMEN

Fluidic devices exhibiting ion current rectification (ICR), or ionic diodes, are of broad interest for applications including desalination, energy harvesting, and sensing, among others. For such applications a large conductance is desirable, which can be achieved by simultaneously using thin membranes and wide pores. In this paper we demonstrate ICR in micrometer sized conical channels in a thin silicon membrane with pore diameters comparable to the membrane thickness but both much larger than the electrolyte screening length. We show that for these pores the entrance resistance is key not only to Ohmic conductance around 0 V but also for understanding ICR, both of which we measure experimentally and capture within a single analytic theoretical framework. The only fit parameter in this theory is the membrane surface potential, for which we find that it is voltage dependent and its value is excessively large compared to the literature. From this we infer that surface charge outside the pore strongly contributes to the observed Ohmic conductance and rectification by a different extent. We experimentally verify this hypothesis in a small array of pores and find that ICR vanishes due to pore-pore interactions mediated through the membrane surface, while Ohmic conductance around 0 V remains unaffected. We find that the pore-pore interaction for ICR is set by a long-ranged decay of the concentration which explains the surprising finding that the ICR vanishes for even a sparsely populated array with a pore-pore spacing as large as 7 µm.

3.
Membranes (Basel) ; 13(1)2022 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-36676829

RESUMEN

Advances in polymer science have significantly increased polymer applications in life sciences. We report the use of free-standing, ultra-thin polydimethylsiloxane (PDMS) membranes, called CellDrum, as cell culture substrates for an in vitro wound model. Dermal fibroblast monolayers from 28- and 88-year-old donors were cultured on CellDrums. By using stainless steel balls, circular cell-free areas were created in the cell layer (wounding). Sinusoidal strain of 1 Hz, 5% strain, was applied to membranes for 30 min in 4 sessions. The gap circumference and closure rate of un-stretched samples (controls) and stretched samples were monitored over 4 days to investigate the effects of donor age and mechanical strain on wound closure. A significant decrease in gap circumference and an increase in gap closure rate were observed in trained samples from younger donors and control samples from older donors. In contrast, a significant decrease in gap closure rate and an increase in wound circumference were observed in the trained samples from older donors. Through these results, we propose the model of a cell monolayer on stretchable CellDrums as a practical tool for wound healing research. The combination of biomechanical cell loading in conjunction with analyses such as gene/protein expression seems promising beyond the scope published here.

4.
Nanotechnology ; 32(41)2021 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-34214991

RESUMEN

In our previous studies, ultrathin SiN membranes down to 3 nm in thickness were fabricated using the poly-Si sacrificial layer process, and nanopores were formed in those membranes. The region of the SiN membrane fabricated using this process was small, and the poly-Si sacrificial layer remained throughout the other region. On the other hand, to reduce the noise of the current through the nanopore, it is preferable to reduce the capacitance of the nanopore chip by replacing the poly-Si layer with an insulator with low permittivity, such as SiO2. Thus, in this study, the fabrication of SiN membranes with thicknesses of 3-7 nm using the SiO2sacrificial layer process was examined. SiN membranes with thicknesses of less than 5 nm could not be formed when the thickness of the top SiN layer deposited onto the sacrificial layer was 100 nm. In contrast, SiN membranes down to 3.07 nm in thickness could be formed when the top SiN layer was 40 nm in thickness. This is thought to be due to the difference in membrane stress. Nanopores were then fabricated in the membranes via dielectric breakdown. The current noise of the nanopore membranes was approximately 3/5 that of membranes fabricated using the poly-Si sacrificial layer process. Last, ionic current blockades were measured when poly(dT)60passed through the nanopores, and the effective thickness of the nanopores was estimated based on those current-blockade values. The effective thickness was approximately 4.8 nm when the deposited thickness of the SiN membrane was 6.03 nm. On the other hand, the effective thickness and the deposited thickness were almost the same when the deposited thickness was 3.07 nm. This suggests it became difficult to form a shape in which the thickness of the nanopore edge was thinner than the deposited membrane thickness as the deposited thickness decreased.

5.
Nano Lett ; 21(12): 5233-5239, 2021 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-34106717

RESUMEN

All-solid-state lithium batteries (ASSLBs) employing Li-metal anode, sulfide solid electrolyte (SE) can deliver high energy density with high safety. The thick SE separator and its low ionic conductivity are two major challenges. Herein, a 30 µm sulfide SE membrane with ultrahigh room temperature conductivity of 8.4 mS cm-1 is realized by mechanized manufacturing technologies using highly conductive Li5.4PS4.4Cl1.6 SE powder. Moreover, a 400 nm magnetron sputtered Al2O3 interlayer is introduced into the SE/Li interface to improve the anodic stability, which suppresses the short circuit in Li/Li symmetric cells. Combining these merits, ASSLBs with LiNi0.5Co0.2Mn0.3O2 as the cathode exhibit a stable cyclic performance, delivering a discharge specific capacity of 135.3 mAh g-1 (1.4 mAh cm-2) with a retention of 80.2% after 150 cycles and an average Coulombic efficiency over 99.5%. The high ionic conductivity SE membrane and interface design principle show promising feasible strategies for practical high performance ASSLBs.

6.
Polymers (Basel) ; 12(8)2020 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-32756335

RESUMEN

We prepared ultrathin PFSA/PFSA-vinylon/PFSA laminated electrolyte membranes (thickness = 10 µm) for fuel cells without using a reinforcing material. Nafion and Aquivion solutions were used as PFSA polymers. Vinylon was synthesized by formalizing polyvinyl alcohol. From the current-voltage measurements using ultrathin PFSA/PFSA-vinylon/PFSA membranes; the cell resistances are significantly lower than that using a 50 µm Nafion membrane. A high current density was obtained under both low- and high-humidity conditions. Ultrathin PFSA/PFSA-vinylon/PFSA laminated membranes will help to further improve the performance of PEMFCs.

7.
Nanomaterials (Basel) ; 10(4)2020 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-32268599

RESUMEN

In this study, transparent membranes containing luminescent Tb3+ and Eu3+ complex-doped silica nanoparticles were prepared via electrospinning. We prepared the electrospun fibrous membranes containing Tb(acac)3phen- (acac = acetylacetone, phen = 1,10-phenanthroline) and/or Eu(tta)3phen- (tta = 2-thenoyltrifluoroacetone) doped silica (M-Si-Tb3+ and M-Si-Eu3+) and studied their photoluminescence properties. The fibrous membranes containing the rare earth complexes were prepared by electrospinning. The surface morphology and thermal properties of the fibrous membrane were studied by atomic force microscopy (AFM), thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC), respectively. Fluorescence spectroscopy was used to characterize the fluorescence properties of the membranes. During the electrospinning process, the PVDF transitions from the α phase to the ß phase, which exhibits a more rigid structure. The introduction of rigid materials, like PVDF and silica, can improve the fluorescence properties of the hybrid materials by reducing the rate of nonradiative decay. So the emission spectra at 548 nm (Tb) and 612 nm (Eu) were enhanced, as compared to the emission from the pure complex. Furthermore, the fluorescence lifetimes ranged from 0.6 to 1.5 ms and the quantum yields ranged from 32% to 61%. The luminescent fibrous membranes have potential applications in the fields of display panels, innovative electronic and optoelectronic devices.

8.
Biomed Microdevices ; 19(4): 98, 2017 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-29116412

RESUMEN

Thin and flexible polymeric membranes play a critical role in tissue engineering applications for example organs-on-a-chip. These flexible membranes can enable mechanical stretch of the engineered tissue to mimic organ-specific biophysical features, such as breathing. In this work, we report the fabrication of thin (<20 µm), stretchable, and biocompatible polyurethane (PU) membranes. The membranes were fabricated using spin coating technique on silicon substrates and were mounted on a frame for ease of device integration and handling. The membranes were characterized for their optical and elastic properties and compatibility with cell/tissue culture. It was possible to apply up to 10 kilopascal (kPa) pressure to perform cyclic stretch on 4 mm-diameter membranes for a period of 2 weeks at 0.2 hertz (Hz) frequency without mechanical failure. Adenocarcinomic human alveolar basal epithelial (A549) cells were cultured on the apical side of the PU membrane. The morphology and viability of the cells were comparable to those of cells cultured on standard tissue culture plates. Our experiments suggest that the stretchable PU membrane will be broadly useful for various tissue engineering applications in vitro.


Asunto(s)
Membranas/química , Poliuretanos/química , Ingeniería de Tejidos , Células A549 , Materiales Biocompatibles/química , Materiales Biomiméticos , Supervivencia Celular , Humanos , Dispositivos Laboratorio en un Chip , Modelos Teóricos , Polímeros/química , Andamios del Tejido
9.
Rev. méd. Chile ; 144(9): 1218-1221, set. 2016. ilus
Artículo en Español | LILACS | ID: biblio-830631

RESUMEN

HIV infection has different clinical presentations. We report a 21-year-old male with longstanding isolated microscopic hematuria attributed to thin glomerular basement membrane disease, who after 15 years of follow-up presented with significant proteinuria. A kidney biopsy was performed, revealing the presence of tubulo-reticular inclusions in the glomerular endothelial cells. This finding led to suspect an HIV infection, which was verified. Antiretroviral therapy, angiotensin-converting enzyme and angiotensin II receptor blockers were prescribed. At 6 years of diagnosis the patient is asymptomatic and has normal kidney function. Microscopic hematuria and low level proteinuria persists.


Asunto(s)
Humanos , Masculino , Adulto , Adulto Joven , Nefropatía Asociada a SIDA/diagnóstico , Hematuria/diagnóstico , Proteinuria/orina , Factores de Tiempo , Biopsia , Nefropatía Asociada a SIDA/complicaciones , Hematuria/complicaciones , Túbulos Renales/ultraestructura
10.
Biomaterials ; 67: 254-63, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26231916

RESUMEN

The aim of this paper is to present a method to produce macroporous thin membranes made of poly (ethyl acrylate-co-hydroxyethyl acrylate) copolymer network with varying cross-linking density for cell transplantation and prosthesis fabrication. The manufacture process is based on template techniques and anisotropic pore collapse. Pore collapse was produced by swelling the membrane in acetone and subsequently drying and changing the solvent by water to produce 100 microns thick porous membranes. These very thin membranes are porous enough to hold cells to be transplanted to the organism or to be colonized by ingrowth from neighboring tissues in the organism, and they present sufficient tearing stress to be sutured with surgical thread. The obtained pore morphology was observed by Scanning Electron Microscope, and confocal laser microscopy. Mechanical properties were characterized by stress-strain experiments in tension and tearing strength measurements. Morphology and mechanical properties were related to the different initial thickness of the scaffold and the cross-linking density of the polymer network. Seeding efficiency and proliferation of mesenchymal stem cells inside the pore structure were determined at 2 h, 1, 7, 14 and 21 days from seeding.


Asunto(s)
Trasplante de Células/métodos , Membranas Artificiales , Medicina Regenerativa/métodos , Citoesqueleto de Actina/efectos de los fármacos , Citoesqueleto de Actina/metabolismo , Animales , Proliferación Celular/efectos de los fármacos , Reactivos de Enlaces Cruzados/farmacología , ADN/metabolismo , Técnica del Anticuerpo Fluorescente , Fenómenos Mecánicos , Células Madre Mesenquimatosas/citología , Células Madre Mesenquimatosas/efectos de los fármacos , Porosidad , Sus scrofa , Andamios del Tejido/química , Vinculina/metabolismo
11.
ACS Nano ; 9(6): 6555-64, 2015 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-26035079

RESUMEN

Solid-state nanopores are single-molecule sensors that detect changes in ionic conductance (ΔG) when individual molecules pass through them. Producing high signal-to-noise ratio for the measurement of molecular structure in applications such as DNA sequencing requires low noise and large ΔG. The latter is achieved by reducing the nanopore diameter and membrane thickness. While the minimum diameter is limited by the molecule size, the membrane thickness is constrained by material properties. We use molecular dynamics simulations to determine the theoretical thickness limit of amorphous Si membranes to be ∼1 nm, and we designed an electron-irradiation-based thinning method to reach that limit and drill nanopores in the thinned regions. Double-stranded DNA translocations through these nanopores (down to 1.4 nm in thickness and 2.5 nm in diameter) provide the intrinsic ionic conductance detection limit in Si-based nanopores. In this regime, where the access resistance is comparable to the nanopore resistance, we observe the appearance of two conductance levels during molecule translocation. Considering the overall performance of Si-based nanopores, our work highlights their potential as a leading material for sequencing applications.


Asunto(s)
ADN/química , Nanoporos , Nanotecnología , Silicio/química , Conductividad Eléctrica , Simulación de Dinámica Molecular , Nanotecnología/instrumentación , Tamaño de la Partícula , Propiedades de Superficie
12.
Int Wound J ; 12(4): 428-31, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23834497

RESUMEN

Burn wound care today has a primary objective of temporary or permanent wound closure. Commercially available engineered alternative tissues have become a valuable adjunct to the treatment of burn injuries. Their constituents can be biological, alloplastic or a combination of both. Here the authors describe the aspects of the development of a siloxane epidermis for a collagen-glycosaminoglycan and for nylon-based artificial skin replacement products. A method to fabricate an ultra-thin epidermal equivalent is described. Pores, to allow the escape of wound exudate, were punched and a tri-filament nylon mesh or collagen scaffold was imbedded and silicone polymerisation followed at 120°C for 5 minutes. The ultra-structure of these bilaminates was assessed through scanning electron microscopy. An ultra-thin biomedical grade siloxane film was reliably created through precision coating on a pre-treated polyethylene terephthalate carrier.


Asunto(s)
Quemaduras/terapia , Colágeno/uso terapéutico , Epidermis/ultraestructura , Nylons , Siloxanos/uso terapéutico , Piel Artificial , Ingeniería de Tejidos/métodos , Materiales Biocompatibles Revestidos/uso terapéutico , Humanos , Siliconas , Trasplante de Piel , Andamios del Tejido , Trasplante Autólogo , Cicatrización de Heridas/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA