1.
Materials (Basel) ; 16(19)2023 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-37834502

RESUMEN

During the cutting process, large quantities of emitted heat are concentrated on a small surface area of the interface between the workpiece and the cutting edge. The resultant very high temperature significantly affects the tool life. Knowledge of maximum temperatures to be expected on the cutting edges is important, as it allows the cutting conditions to be adjusted in such a manner that the critical value of thermal resistance is not exceeded for the cutting material. In effect, the maximum effectiveness of the working process is maintained. This article offers a systematic presentation of methods used in cutting temperature measurements. It discusses their advantages and disadvantages, as well as the usefulness of the individual methods in different types of machining processes. It also points to the possibility of methodological errors which significantly reduce measurement accuracy. The above issues are believed to justify a discussion of different cutting temperature measurement methods. The conclusions here presented may be of particular importance to researchers interested in the field, especially in high-efficiency machining, new cutting materials and cutting-edge protective coatings, as well as various methods for cutting fluid applications. They may allow a more informed selection of measurement methods most suitable for particular situations.

2.
Sensors (Basel) ; 23(16)2023 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-37631605

RESUMEN

One of the threats to nanometric CMOS analog circuit reliability is circuit performance degradation due to transistor aging. To extend circuit operating life, the bias of the main devices within the circuit must be adjusted while the aging degradation process affects them by using a monitor circuit that tracks the evolution of the circuit performance. In this paper, we propose the use of DC temperature measurements in the proximity of the circuit to perform the monitoring of circuit performance degradation and as an observable variable to adjust the bias of the main devices to restore the degraded performance to the original values. To this end, we present experimental results obtained from nine samples of a standard CMOS integrated circuit containing a high-frequency class-A power amplifier and a differential temperature sensor. After accelerated aging, the gain of the amplifier is degraded up to 50%. We propose two different procedures to perform DC temperature measurements that allow tracking of the amplifier gain degradation due to aging and, by uniquely observing temperature readings, automatically set a new bias for the amplifier devices that restores the original amplifier gain. Whereas one of the procedures is able to restore the gain up to a certain limit, the second allows full gain restoration.

3.
Sensors (Basel) ; 23(13)2023 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-37448034

RESUMEN

This paper presents reported machine learning approaches in the field of Brillouin distributed fiber optic sensors (DFOSs). The increasing popularity of Brillouin DFOSs stems from their capability to continuously monitor temperature and strain along kilometer-long optical fibers, rendering them attractive for industrial applications, such as the structural health monitoring of large civil infrastructures and pipelines. In recent years, machine learning has been integrated into the Brillouin DFOS signal processing, resulting in fast and enhanced temperature, strain, and humidity measurements without increasing the system's cost. Machine learning has also contributed to enhanced spatial resolution in Brillouin optical time domain analysis (BOTDA) systems and shorter measurement times in Brillouin optical frequency domain analysis (BOFDA) systems. This paper provides an overview of the applied machine learning methodologies in Brillouin DFOSs, as well as future perspectives in this area.


Asunto(s)
Tecnología de Fibra Óptica , Dispositivos Ópticos , Fibras Ópticas , Humedad , Aprendizaje Automático
4.
J Colloid Interface Sci ; 638: 640-649, 2023 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-36774877

RESUMEN

Luminescence thermometry using sharp line emission of lanthanide ions has become an active area of research as it offers the advantages of remote temperature sensing with high sensitivity and superior spatial resolution. The most widely applied method relies on the temperature dependence of the luminescence intensity ratio of emission lines from two thermally coupled levels. However, the usable temperature range for this type of Boltzmann thermometer is limited. In addition, the weak and narrow line absorption of the parity forbidden 4f-4f transitions of lanthanides forms a serious drawback. To solve both problems, we here report a new dual functionality luminescence thermometer: Gd2O2S co-doped with Eu3+ and Nd3+. This material combines Boltzmann and energy transfer thermometry to extend the temperature range and uses the strong and broad charge transfer absorption band of Eu3+ for sensitization. In the T-range of 300-500 K efficient energy transfer from Eu3+ to Nd3+ allows for charge transfer-sensitized luminescence thermometry using near infrared emission from the thermally coupled 4F3/2 and 4F5/2 levels of Nd3+. Above 500 K a high temperature sensitivity is obtained using the strong temperature dependence of the luminescence intensity ratio of red Eu3+ to near infrared Nd3+ emission. The dual-functionality provides a single thermometer combining strong absorption and high relative sensitivity (0.6 - 1.4%) over a wide temperature range (300 to 650 K). Finally, it is proposed that this dual-function luminescent thermometer has promising potential for multifunctional applications in biosensors and in situ temperature measurements of chemical reaction process.

5.
Sensors (Basel) ; 23(2)2023 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-36679417

RESUMEN

A new version of a sensor for temperature measurements in the case of strong laser intensity fluctuation was developed. It was based on tunable diode laser absorption spectroscopy (TDLAS) with wavelength modulation, logarithmic conversion of the absorption signal, and detection of the first harmonic of the modulation frequency. The efficiency of the technique was demonstrated under experimental conditions with excess multiplicative noise. Temperature was evaluated from the ratio of integrated absorbance of two lines of the water molecule with different lower energy levels. Two algorithms of data processing were tested, simultaneous fitting of two spectral ranges with selected absorption lines and independent fitting of two absorption lines profiles. The correctness of the gas temperature evaluation was verified by simultaneous measurements with a commercial thermocouple. An error in temperature evaluation of less than 40 at 1000 K was achieved even when processing a single scan of the diode lasers.


Asunto(s)
Algoritmos , Láseres de Semiconductores , Temperatura , Análisis Espectral , Agua
6.
Micromachines (Basel) ; 13(10)2022 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-36295994

RESUMEN

In this work, we investigate the effect of temperature on the electrical characteristics of Al/SiO2/n++-Si RRAM devices. We study the electroforming process and show that forming voltage and time-to-breakdown are well described by Weibull distribution. Experimental current-voltage characteristics of Al-SiO2-(n++Si) structures are presented and discussed at different temperatures. We show that some intermediate resistance states can be observed at higher temperatures. In our analysis, we identify Space Charge Limited Conduction (SCLC) as the dominating transport mechanism regardless of the operating temperature.

7.
Sensors (Basel) ; 22(15)2022 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-35957473

RESUMEN

We developed and tested a microwave in situ salinity sensor (MiSSo) to simultaneously measure salinity and temperature within the same water sample over broad ranges of salinity (S) (3−50 psu) and temperature (T) (3−30 °C). Modern aquatic S sensors rely on measurements of conductivity (C) between a set of electrodes contained within a small volume of water. To determine water salt content or S, conductivity, or C, measurements must be augmented with concurrent T measurements from the same water volume. In practice, modern S sensors do not sample C and T within the same volume, resulting in the S determination characterized by measurement artifacts. These artifacts render processing vast amounts of available C and T data to derive S time-consuming and generally preclude automated processing. Our MiSSo approach eliminates the need for an additional T sensor, as it permits us to concurrently determine the sample S and T within the same water volume. Laboratory trials demonstrated the MiSSo accuracy of S and T measurements to be <0.1 psu and <0.1 °C, respectively, when using microwave reflections at 11 distinct frequencies. Each measurement took 0.1 µs. Our results demonstrate a new physical method that permits the accurate S and T determination within the same water volume.


Asunto(s)
Microondas , Salinidad , Conductividad Eléctrica , Temperatura , Agua
8.
Sensors (Basel) ; 22(16)2022 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-36015902

RESUMEN

The understanding of blast loads is critical for the development of infrastructure that protects against explosions. However, the lack of high-quality experimental work on the characterisation of such loads prevents a better understanding of many scenarios. Blast loads are typically characterised by use of some form of pressure gauge, from which the temperature can be inferred from a pressure measurement. However, such an approach to temperature measurement is limited; it assumes ideal gas laws apply throughout, which may not be the case for high temperature and pressure scenarios. In contrast, infrared radiation thermometers (IRTs) perform a measurement of temperature based upon the emitted radiance from the target object. The IRTs can measure fast changes in transient temperature, making them seemingly ideal for the measurement of a fireball's temperature. In this work, we present the use of a high-speed IRT for the measurement of early-stage explosive development and fireball expansion within a confined blast, with the temperature of the explosive fireball measured from its emitted radiance. The temperature measured by the IRT was corroborated against the temperature inferred from a pressure gauge measurement; both instruments measured the same temperature from the quasi-static pressure (QSP) point onwards. Before the QSP point, it is deduced that the IRT measures the average temperature of the fireball over a wide field-of-view (FOV), as opposed to that inferred from the singular shocks detected by the pressure gauge. Therefore, use of an IRT, in tandem with a pressure gauge, provides a potential invaluable measurement technique for the characterisation the early stages of a fireball as it develops and expands.

9.
Int J Low Extrem Wounds ; : 15347346221112257, 2022 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-35791575

RESUMEN

The identification of the key contributing factors which predispose the foot to ulceration, increasing the risk of recurrence and slow wound healing in diabetes mellitus (DM), has led to some significant research studies over the last 30 years, providing valuable insight into the mechanism leading to diabetic foot ulceration (DFU). Although, these contributory factors are similar to those identified in pressure ulceration occurring in other parts of the body (such as "bed pressure sores') where magnitude and/or duration of mechanical stress in the presence of sensory deficits are key causal factors, research investigating pressure ulceration has also included measurement of temperature and relative humidity at the interface between the skin and supporting surface. The possible influence of these parameters (in-shoe temperature and humidity) does not appear frequently in diabetic foot ulceration research. Referred to as "microclimate", this has an important role in the pathway to tissue breakdown evidenced in pressure ulcer research and may be particularly relevant in countries with warm and humid climates. As the microclimate is influential in the ulceration pathway for other body sites, its role in the DFU causal pathway justifies further investigation.

10.
Sensors (Basel) ; 22(9)2022 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-35591009

RESUMEN

Fiber-optic distributed temperature sensing (DTS) has been widely used since the end of the 20th century, with various industrial, Earth sciences, and research applications. To obtain precise thermal measurements, it is important to extend the currently available DTS calibration methods, considering that environmental and deployment factors can strongly impact these measurements. In this work, a laboratory experiment was performed to assess a currently available duplexed single-ended DTS calibration algorithm and to extend it in case no temperature information is available at the end of the cables, which is extremely important in geothermal applications. The extended calibration algorithms were tested in different boreholes located in the Atacama Desert and in the Central Andes Mountains to estimate the geothermal gradient in these regions. The best algorithm found achieved a root mean square error of 0.31 ± 0.07 °C at the far end of a ~1.1-km cable, which is much smaller than that obtained using the manufacturer algorithm (2.17 ± 0.35 °C). Moreover, temperature differences between single- and double-ended measurements were less than 0.3 °C at the far end of the cable, which results in differences of ~0.5 °C km-1 when determining the geothermal gradient. This improvement in the geothermal gradient is relevant, as it can reduce the drilling depth by at least 700 m in the study area. Future work should investigate new extensions of the algorithms for other DTS configurations and determining the flow rate of the Central Andes Mountains artesian well using the geothermal profile provided by the DTS measurements and the available data of the borehole.


Asunto(s)
Tecnología de Fibra Óptica , Sensación Térmica , Algoritmos , Calibración , Tecnología de Fibra Óptica/métodos , Temperatura
11.
Sensors (Basel) ; 22(10)2022 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-35632018

RESUMEN

The evaluation of the biological effects of therapeutic hyperthermia in oncology and the precise quantification of thermal dose, when heating is coupled with radiotherapy or chemotherapy, are active fields of research. The reliable measurement of hyperthermia effects on cells and tissues requires a strong control of the delivered power and of the induced temperature rise. To this aim, we have developed a radiofrequency (RF) electromagnetic applicator operating at 434 MHz, specifically engineered for in vitro tests on 3D cell cultures. The applicator has been designed with the aid of an extensive modelling analysis, which combines electromagnetic and thermal simulations. The heating performance of the built prototype has been validated by means of temperature measurements carried out on tissue-mimicking phantoms and aimed at monitoring both spatial and temporal temperature variations. The experimental results demonstrate the capability of the RF applicator to produce a well-focused heating, with the possibility of modulating the duration of the heating transient and controlling the temperature rise in a specific target region, by simply tuning the effectively supplied power.


Asunto(s)
Hipertermia Inducida , Ondas de Radio , Hipertermia Inducida/métodos , Técnicas In Vitro , Fantasmas de Imagen , Temperatura
12.
Sensors (Basel) ; 22(5)2022 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-35271117

RESUMEN

Knowing the temperature distribution within the conducting walls of various multilayer-type materials is crucial for a better understanding of heat-transfer processes. This applies to many engineering fields, good examples being photovoltaics and microelectronics. In this work we present a novel fluorescence technique that makes possible the non-invasive imaging of local temperature distributions within a transparent, temperature-sensitive, co-doped Er:GPF1Yb0.5Er glass-ceramic with micrometer spatial resolution. The thermal imaging was performed with a high-resolution fluorescence microscopy system, measuring different focal planes along the z-axis. This ultimately enabled a precise axial reconstruction of the temperature distribution across a 500-µm-thick glass-ceramic sample. The experimental measurements showed good agreement with computer-modeled heat simulations and suggest that the technique could be adopted for the spatial analyses of local thermal processes within optically transparent materials. For instance, the technique could be used to measure the temperature distribution of intermediate, transparent layers of novel ultra-high-efficiency solar cells at the micron and sub-micron levels.

13.
Materials (Basel) ; 14(23)2021 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-34885638

RESUMEN

The refill friction stir spot welding (refill FSSW) process is a solid-state joining process to produce welds without a keyhole in spot joint configuration. This study presents a thermo-mechanical model of refill FSSW, validated on experimental thermal cycles for thin aluminium sheets of AA7075-T6. The temperatures in the weld centre and outside the welding zone at selected points were recorded using K-type thermocouples for more accurate validation of the thermo-mechanical model. A thermo-mechanical three-dimensional refill FSSW model was built using DEFORM-3D. The temperature results from the refill FSSW numerical model are in good agreement with the experimental results. Three-dimensional material flow during plunging and refilling stages is analysed in detail and compared to experimental microstructure and hardness results. The simulation results obtained from the refill FSSW model correspond well with the experimental results. The developed 3D numerical model is able to predict the thermal cycles, material flow, strain, and strain rates which are key factors for the identification and characterization of zones as well for determining joint quality.

14.
Grundwasser (Berl) ; 26(3): 269-288, 2021.
Artículo en Alemán | MEDLINE | ID: mdl-34075306

RESUMEN

In Basel (CH), the thermal impact of various subsurface structures on urban groundwater resources, including five underground parking lots and a freeway tunnel, were investigated by monitoring systems. Data were analyzed together with meteorological and groundwater temperature data and results from heat-transport modelling.Significantly elevated temperatures between 18.8 and 21.1 °C were recorded in the underground parking lots, even in winter. Thus, underground parking lots emit heat into the surroundings all year. In comparison, data recorded in the freeway tunnel indicate that in the winter months heat can also be absorbed from below ground.In addition, the temperatures of underground parking lots show a clear dependence on the type of use: with a higher number of daily entrances and exits, greater daily temperature increases were detected, with differences of up to 2 °C. This became particularly clear in the "lockdown" period during the COVID-19 pandemic between March and May 2020.

15.
Sensors (Basel) ; 21(8)2021 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-33920723

RESUMEN

In this work, the authors exploited the whispering gallery mode (WGM) resonator properties as a thermometer. The sensor is made of a cylindrical sapphire microwave resonator in the center of a gold-plated copper cavity. Two coaxial cables act as antennas and excite the WGM standing waves in the cylindrical sapphire at selected resonance frequencies in the microwave range. The system affords a high quality factor that enables temperature measurements with a resolution better than 15 µK and a measurement standard uncertainty of 1.2 mK, a value approximately three times better than that achieved in previous works. The developed sensor could be a promising alternative to platinum resistance thermometers, both as a transfer standard in industrial applications and as an interpolating instrument for the dissemination of the kelvin.

16.
Sensors (Basel) ; 21(4)2021 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-33669692

RESUMEN

Cardiac radiofrequency ablation (RFA) has received substantial attention for the treatment of multiple arrhythmias. In this scenario, there is an ever-growing demand for monitoring the temperature trend inside the tissue as it may allow an accurate control of the treatment effects, with a consequent improvement of the clinical outcomes. There are many methods for monitoring temperature in tissues undergoing RFA, which can be divided into invasive and non-invasive. This paper aims to provide an overview of the currently available techniques for temperature detection in this clinical scenario. Firstly, we describe the heat generation during RFA, then we report the principle of work of the most popular thermometric techniques and their features. Finally, we introduce their main applications in the field of cardiac RFA to explore the applicability in clinical settings of each method.


Asunto(s)
Ablación por Catéter , Miocardio , Ablación por Radiofrecuencia , Termometría , Temperatura
17.
Int J Low Extrem Wounds ; 20(2): 111-118, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32106729

RESUMEN

Prior to the appearance of any foot ulcer, there is an increase in the local temperature due to the presence of an underlying inflammatory process. The use of thermometry to identify inflammation could make patients increase preventive measures until the inflammation disappears. We carried out a meta-analysis to determine the effectiveness of the daily measurement of the foot temperature in 6 points to prevent the occurrence of foot ulcers in patients with diabetes. Patients with temperature differences >4°F (2.2°C) between left and right corresponding sites should reduce activity and increase preventive measures until temperature is normalized. We searched the literature in MEDLINE, EMBASE, Cochrane Library, Web of Knowledge, and clinicaltrials.gov. We have only included randomized clinical trials where individuals were assigned to receive enhanced care (temperature measurement and standard care) versus standard care (education, self-care practices, and periodic clinical visits). We found 4 trials comprising 462 patients from the United States and Norway that met our inclusion criteria. The duration of follow-up varied from 4.5 to 15 months. Overall, 18 (7.9%) subjects in the enhanced foot care group and 53 (22.6%) in the standard foot care group developed foot ulcers (pooled risk ratio = 0.37; 95% confidence interval = 0.21-0.66; P = .0008; percentage of heterogeneity [I2], 25%; P = .26). The number needed to treat was 7 (95% confidence interval = 5-11). The results were robust after analysis by subgroups according to the potential risk of bias in the studies and the duration of follow-up.


Asunto(s)
Diabetes Mellitus , Pie Diabético , Úlcera del Pie , Pie Diabético/diagnóstico , Pie Diabético/epidemiología , Humanos , Incidencia , Temperatura Cutánea
18.
Entropy (Basel) ; 22(9)2020 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-33286719

RESUMEN

In recent years, there has been increasing interest in the development of micron-scale devices utilizing thermal gradients to manipulate molecules and colloids, and to measure their thermophoretic properties quantitatively. Various devices have been realized, such as on-chip implements, micro-thermogravitational columns and other micron-scale thermophoretic cells. The advantage of the miniaturized devices lies in the reduced sample volume. Often, a direct observation of particles using various microscopic techniques is possible. On the other hand, the small dimensions lead to some technical problems, such as a precise temperature measurement on small length scale with high spatial resolution. In this review, we will focus on the "state of the art" thermophoretic micron-scale devices, covering various aspects such as generating temperature gradients, temperature measurement, and the analysis of the current micron-scale devices. We want to give researchers an orientation for their development of thermophoretic micron-scale devices for biological, chemical, analytical, and medical applications.

19.
Sensors (Basel) ; 20(22)2020 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-33202980

RESUMEN

Radiofrequency ablation (RFA) is the most widely used technique for the treatment of cardiac arrhythmias. A variety of factors, such as the electrode tip shape, the force exerted on the tissue by the catheter and the delivered power, combine to determine the temperature distribution, and as consequence, the lesion shape and size. In this context, being able to know the temperature reached in the myocardium during the RFA can be helpful for predicting the lesion dimensions to prevent the occurrence of undesired tissue damage. The catheters used so far in such procedures provide single-point temperature measurements within the probe (by means of embedded thermocouples or thermistors), so no information regarding the temperature changes occurring in myocardial tissues can be retrieved. The aim of this study was to assess the feasibility of fiber Bragg grating sensors (FBGs) to perform multi-point and millimetric-scale temperature measurements within myocardium subjected to RFA. The assessment has been performed on ex vivo porcine myocardium specimens undergoing RFA. Data show the feasibility of the proposed solution in providing spatial temperature distribution within the myocardial tissue during the entire RFA. These high-resolved measurements may allow reconstructing the temperature distribution in the tissue. This study lays the foundations for the implementation of 3D thermal maps to investigate how the supplied power, treatment time, force of contact and irrigation flow of the catheter influence the thermal effects within the tissue.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Corazón/fisiología , Ablación por Radiofrecuencia , Temperatura , Animales , Estudios de Factibilidad , Miocardio , Porcinos
20.
Sensors (Basel) ; 20(22)2020 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-33203048

RESUMEN

Laser ablation (LA) of cancer is a minimally invasive technique based on targeted heat release. Controlling tissue temperature during LA is crucial to achieve the desired therapeutic effect in the organs while preserving the healthy tissue around. Here, we report the design and implementation of a real-time monitoring system performing closed-loop temperature control, based on fiber Bragg grating (FBG) spatial measurements. Highly dense FBG arrays (1.19 mm length, 0.01 mm edge-to-edge distance) were inscribed in polyimide-coated fibers using the femtosecond point-by-point writing technology to obtain the spatial resolution needed for accurate reconstruction of high-gradient temperature profiles during LA. The zone control strategy was implemented such that the temperature in the laser-irradiated area was maintained at specific set values (43 and 55 °C), in correspondence to specific radii (2 and 6 mm) of the targeted zone. The developed control system was assessed in terms of measured temperature maps during an ex vivo liver LA. Results suggest that the temperature-feedback system provides several advantages, including controlling the margins of the ablated zone and keeping the maximum temperature below the critical values. Our strategy and resulting analysis go beyond the state-of-the-art LA regulation techniques, encouraging further investigation in the identification of the optimal control-loop.


Asunto(s)
Terapia por Láser , Hígado/cirugía , Temperatura , Animales , Rayos Láser