Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Cureus ; 16(5): e59611, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38832189

RESUMEN

Background and objective Diffuse coronary artery disease (CAD) is associated with extensive involvement of coronary arteries, necessitating the use of long (≥40 mm) drug-eluting stents (DES) based on the lesion length. However, these long DES can lead to complications such as in-stent restenosis (ISR) and stent thrombosis. This study aimed to assess the safety, efficacy, and one-year clinical outcomes of using long DES in patients with diffuse CAD undergoing PCI at a tertiary care hospital in north India. Methodology Patients with diffuse CAD undergoing PCI with long DES between January 2017 and June 2022 were included in the study. Baseline characteristics were recorded, and patients were followed up telephonically or in the outpatient department (OPD) at one, three, six, and 12 months following the PCI. The primary endpoint was the target lesion failure (TLF) rate, with secondary endpoints constituting all-cause mortality, major adverse cardiovascular events (MACE), subacute stent thrombosis, and ISR. Results A total of 200 patients were recruited and followed up for one year. The median age of the patients was 58 years (range: 48.25-63 years), and 82% were men. The most frequently stented artery was the left anterior descending (LAD, 48%), followed by the right coronary artery (RCA, 36%). A total of 388 stents (mean: 1.94 ±0.79) were implanted, including both long and short stents. The mean length and diameter of long stents were 43.64 ±3.58 mm and 3 ±0.37 mm, respectively. At the one-year follow-up, patients undergoing PCI with long DES ≥40 mm had an overall TLF rate of 5%, all-cause mortality of 6% (12 patients), MACE of 6% (12 patients), subacute stent thrombosis of 4% (eight patients), and ISR of 1% (two patients). A large proportion of patients (90%) had an uneventful follow-up of up to a year. At the one-year follow-up, all 10 (5%) patients with a primary outcome had a smaller stent diameter than those without a primary outcome (2.5 ±0.25 mm vs. 3.03 ±0.35 mm, p=0.015). Conclusions Our results suggest that using extremely long stents (>40 mm) for diffuse coronary lesions is safe, efficacious, and associated with relatively low event rates. In addition, the stent diameter has a substantial correlation with the primary outcome. Further studies with larger sample sizes as well as longer follow-up periods are required to validate our findings.

2.
Cureus ; 16(3): e56346, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38633944

RESUMEN

BACKGROUND: Drug-eluting stents (DES) are the major treatment option in percutaneous coronary intervention (PCI). Recently, drug-coated balloon (DCB) utilization has been increasing globally, leading to the expected new strategy of "stent-less PCI." This study aimed to evaluate the one-year outcome of DCB compared to DES. METHODS: Patients who underwent initial PCI for de novo lesions in our institution from January 2018 to December 2021 (n=337) were subjected to retrospective analysis. Among them, 75 patients were treated with DCB, while 262 patients were treated with DES. Target lesion failure (TLF) was evaluated during the follow-up period. RESULTS: The proportion of PCIs for ACS was significantly lower in the DCB group (DCB, n=23, 30.7% vs. DES, n=143, 54.6%; p=0.001). The median device diameter and length in the DES group were larger than those in the DCB group (DCB, 2.60 mm vs. DES, 2.98 mm; p<0.001; DCB, 19.1 mm vs. DES, 25.2 mm; p<0.001). There was no significant difference between the DCB and DES groups in lesion calcification. The proportion of ostial lesions was significantly higher in the DCB group (DCB, n=13, 17.3% vs. DES, n=21, 8.0%; p=0.018). The cumulative rate of TLF (DCB, n=5, 6.7% vs. DES, n=18, 6.9%; p=0.951) did not significantly differ between the DCB and DES groups. CONCLUSION: DCB may be as effective a strategy as DES in the patient who underwent initial PCI for a de novo lesion.

3.
Herz ; 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38656396

RESUMEN

BACKGROUND: This study aimed to evaluate the long-term outcomes of double kissing crush stenting (DKC) and mini-culotte technique (MCT) in patients with complex bifurcation lesions. METHODS: This retrospective study enrolled 236 patients who underwent percutaneous coronary intervention (PCI) for complex coronary bifurcation disease between January 2014 and November 2022. The primary endpoint was target lesion failure (TLF), defined as the combination of cardiac death, myocardial infarction (MI), or clinically driven target lesion revascularization (TLR). The secondary endpoint was major cardiovascular and cerebral events (MACCE) including all-cause death, MI, TLR, stroke, or stent thrombosis. The regression models were adjusted by applying the inverse probability weighted (IPW) approach to reduce treatment selection bias. RESULTS: The initial management strategy was DKC in 154 (65.3%) patients and MCT in 82 (34.7%) patients (male: 194 [82.2%], mean age: 60.85 ± 10.86 years). The SYNTAX scores were similar in both groups. The rates of long-term TLF and MACCE rates were 17.4% and 20%, respectively. The rate of TLF (26.8% vs. 12.3%, p = 0.005) was higher in patients treated with MCT than those treated with the DKC technique, mainly driven by more frequent TLR (15.9% vs. 7.1%, p = 0.035). The long-term TLF and MACCE rates were notably lower in the DKC group compared to the others: adjusted hazard ratio (HR; IPW): 0.407, p = 0.009 for TLF, and adjusted HR(IPW): 0.391 [95% CI: 0.209-0.730], p = 0.003 for MACCE. CONCLUSION: At long-term follow-up, the rates of TLF and MACCE were 17.4% and 20%, respectively. However, long-term TLF was significantly higher in patients treated with MCT than those treated with the DKC technique, primarily due to a more frequent occurrence of clinically driven TLR.

4.
Catheter Cardiovasc Interv ; 103(2): 276-285, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38091338

RESUMEN

BACKGROUND: Patients with acute coronary syndromes (ACS) may have worse outcomes after percutaneous coronary intervention compared to patients without ACS. AIMS: To compare 5-year efficacy and safety outcomes in patients with and without ACS treated with biodegradable polymers, the ultrathin strut sirolimus-eluting Orsiro stent (O-SES) or the biolimus-eluting Nobori stent (N-BES). METHODS: The Scandinavian Organisation for Randomized Trials with Clinical Outcome VII is a randomized trial comparing O-SES and N-BES in an all-comer setting. Of 2525 patients, 1329 (53%) patients had ACS and 1196 (47%) patients were without ACS. Endpoints were target lesion failure (TLF) (a composite of cardiac death, target lesion myocardial infarction, or target lesion revascularization) and definite stent thrombosis within 5 years. RESULTS: At 5-year follow-up, TLF did not differ significantly between patients with and without ACS (12.3% vs. 13.2%; rate ratio (RR) 1.00; 95% confidence interval (CI): 0.70-1.44), whereas the risk of definite stent thrombosis was increased in patients with ACS (2.3% vs. 1.3; RR: 2.01 [95% CI: 1.01-3.98]). In patients with ACS, the rate of TLF was similar between O-SES and N-BES (12.4% vs. 12.3%; RR: 1.02; 95% CI: 0.74-1.40). The reduced risk of definite stent thrombosis in O-SES treated ACS patients within the first year (0.2% vs. 1.6%; RR: 0.12; 95% CI: 0.02-0.93) was not maintained after 5 years (1.8% vs. 2.7%; RR: 0.77; 95% CI: 0.37-1.63). CONCLUSION: Patients with ACS had an increased risk of stent thrombosis regardless of the stent type used. Long-term outcomes were similar for ACS patients treated with O-SES or N-BES at 5 years.


Asunto(s)
Síndrome Coronario Agudo , Ácidos Alcanesulfónicos , Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Trombosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/complicaciones , Factores de Riesgo , Resultado del Tratamiento , Stents Liberadores de Fármacos/efectos adversos , Implantes Absorbibles , Diseño de Prótesis , Fármacos Cardiovasculares/efectos adversos , Trombosis Coronaria/etiología , Stents/efectos adversos , Polímeros , Intervención Coronaria Percutánea/efectos adversos
5.
Eur Heart J Digit Health ; 4(6): 433-443, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38045434

RESUMEN

Aims: Central to the practice of precision medicine in percutaneous coronary intervention (PCI) is a risk-stratification tool to predict outcomes following the procedure. This study is intended to assess machine learning (ML)-based risk models to predict clinically relevant outcomes in PCI and to support individualized clinical decision-making in this setting. Methods and results: Five different ML models [gradient boosting classifier (GBC), linear discrimination analysis, Naïve Bayes, logistic regression, and K-nearest neighbours algorithm) for the prediction of 1-year target lesion failure (TLF) were trained on an extensive data set of 35 389 patients undergoing PCI and enrolled in the global, all-comers e-ULTIMASTER registry. The data set was split into a training (80%) and a test set (20%). Twenty-three patient and procedural characteristics were used as predictive variables. The models were compared for discrimination according to the area under the receiver operating characteristic curve (AUC) and for calibration. The GBC model showed the best discriminative ability with an AUC of 0.72 (95% confidence interval 0.69-0.75) for 1-year TLF on the test set. The discriminative ability of the GBC model for the components of TLF was highest for cardiac death with an AUC of 0.82, followed by target vessel myocardial infarction with an AUC of 0.75 and clinically driven target lesion revascularization with an AUC of 0.68. The calibration was fair until the highest risk deciles showed an underestimation of the risk. Conclusion: Machine learning-derived predictive models provide a reasonably accurate prediction of 1-year TLF in patients undergoing PCI. A prospective evaluation of the predictive score is warranted. Registration: Clinicaltrial.gov identifier is NCT02188355.

6.
Cardiovasc Diabetol ; 22(1): 283, 2023 10 21.
Artículo en Inglés | MEDLINE | ID: mdl-37865782

RESUMEN

BACKGROUND: Early diagnosis and treatment effectiveness of early-onset coronary artery disease (EOCAD) are crucial, and non-invasive predictive biomarkers are needed for young adults. We aimed to evaluate the usefulness of the triglyceride-glucose (TyG) index, a novel marker of insulin resistance, in identifying young CAD patients and predicting their risk of developing target lesion failure (TLF). METHODS: We recruited EOCAD patients (luminal narrowing ≥ 70%) and controls free from CAD (luminal narrowing < 30%), both aged 45 years or younger, from 38 hospitals in China between 2017 and 2020. EOCAD patients who underwent successful percutaneous coronary intervention were followed for incident TLF. TyG index was defined as Ln [fasting triglyceride (mg/dL) × fasting blood glucose (mg/dL)/2]. We used logistic regression and Cox proportional hazards modeling to evaluate the association of TyG index with prevalent EOCAD and incident TLF, respectively. The discriminatory ability of TyG index was assessed by the area under the receiver-operating characteristic curve (AUC). RESULTS: Among the included 1513 EOCAD patients (39.6 ± 4.4 years, 95.4% male) and 1513 age-matched controls (39.0 ± 4.4 years, 46.4% male), TyG index was positively associated with the prevalence of EOCAD (adjusted odds ratio: 1.40, 95% confidence interval [CI] 1.23-1.60, per standard deviation [SD] increase in TyG index). The addition of TyG index to an empirical risk model provided an improvement in diagnostic ability for EOCAD, with a net reclassification improvement of 0.10 (95% CI 0.03-0.17, p = 0.005). During a medium of 33 month (IQR: 31-34 months) follow-up, 43 (3.3%) patients experienced TLF. Multivariate Cox regression model revealed that TyG index was an independent risk factor for TLF (adjusted hazard ratio [HR]: 2.410, 95% CI 1.07-5.42 comparing the top to bottom TyG index tertile groups; HR: 1.30, 95% CI 1.01-1.73, per SD increase in TyG index). Compared with a model of conventional risk factors alone, the addition of the TyG index modestly improved the AUC (0.722-0.734, p = 0.04) to predict TLF. CONCLUSIONS: TyG index is positively associated with prevalent EOCAD and incident TLF. TyG index appeared to be a valuable component of future efforts to improve CAD risk stratification and TLF outcome prediction among young adults.


Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Humanos , Masculino , Adulto Joven , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/terapia , Glucosa , Glucemia , Triglicéridos , Factores de Riesgo , Biomarcadores , Medición de Riesgo
7.
BMC Cardiovasc Disord ; 23(1): 496, 2023 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-37805479

RESUMEN

BACKGROUND: Cell division control 42 (CDC42) regulates atherosclerosis, blood lipids, and inflammation and thus affects coronary artery disease (CAD), but its utility in drug-coated balloon (DCB)-treated small-vessel CAD (SV-CAD) patients is unclear. This study intended to evaluate the change and prognostic role of CDC42 in SV-CAD patients underwent DCB. METHODS: Serum CDC42 was measured by enzyme-linked immunosorbent assay in 211 SV-CAD patients underwent DCB at baseline, day (D) 1, D3, and D7, as well as in 50 healthy controls (HCs). RESULTS: CDC42 was decreased in SV-CAD patients compared to HCs (P < 0.001), and it was negatively associated with total cholesterol (P = 0.015), low-density lipoprotein cholesterol (P = 0.003), C-reactive protein (P = 0.001), multivessel disease (P = 0.020), and American college of cardiology/American heart association type B2/C lesions (P = 0.039) in SV-CAD patients. Longitudinally, CDC42 decreased from baseline to D1 and then gradually increased to D7 (P < 0.001) in SV-CAD patients after DCB. Interestingly, high CDC42 (cut-off value = 500 pg/mL) at baseline (P = 0.047), D3 (P = 0.046), and D7 (P = 0.008) was associated with a lower accumulating target lesion failure (TLF) rate; high CDC42 at D3 (P = 0.037) and D7 (P = 0.041) was related to a lower accumulating major adverse cardiovascular event (MACE) rate in SV-CAD patients underwent DCB. Importantly, CDC42 at D7 (high vs. low) independently predicted lower accumulating TLF (hazard ratio (HR) = 0.145, P = 0.021) and MACE (HR = 0.295, P = 0.023) risks in SV-CAD patients underwent DCB. CONCLUSIONS: Circulating CDC42 level relates to milder disease conditions and independently estimates lower risks of TLF and MACE in SV-CAD patients underwent DCB, but further validation is still needed.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Colesterol
8.
Am J Cardiol ; 206: 73-78, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37683582

RESUMEN

Patients with diabetes mellitus (DM) are at higher risk of restenosis and stent thrombosis after percutaneous coronary intervention (PCI) and drug-eluting stent (DES) positioning. Whether drug-coated balloons (DCB) can offer any benefit in this subset of patients has been seldom cleared out and was the aim of the present propensity-matched cohort study, that compared the prognostic impact of DCB versus DES in patients with DM who underwent PCI. Patients with DM enrolled in the NOvara-BIella-TREnto (NOBITRE) Registry were identified and matched according to propensity score, to a control population of patients with DM treated with DES. The primary study end point was the occurrence of major adverse cardiovascular events (MACEs). A total of 150 patients were identified in the DCB group and matched with 150 DES-treated patients. Patients treated with DCB displayed more often a previous cardiovascular history and received a more complete pharmacological therapy. Target vessel diameter and the percentage of stenosis were lower in patients with DCB, whereas binary in-stent restenosis was more common (p <0.001, p = 0.003, and p <0.001, respectively). Paclitaxel-eluting balloon represented the most common strategy in the DCB group, whereas Zotarolimus-eluting stents were used in half of the DES population. At a median follow-up of 545.5 days, MACE occurred in 54 (19.4%) of patients, with no difference according to the PCI strategy (21.6% vs 17.3%, adjusted hazard ratio [95% confidence interval] 1.51 [0.46 to 4.93], p = 0.50). Major ischemic end points were slightly increased in patients treated with DCB, whereas overall death was significantly reduced (3.6% vs 10.9%; adjusted hazard ratio [95% confidence interval] 0.27 [0.08 to 0.91], p = 0.03). In conclusion, the present propensity-matched study shows that, in patients with DM who underwent PCI for in-stent restenosis or de novo lesions, the use of DCB is associated with a similar rate of MACE and a modest increase in target lesion failure, but a significantly improved survival as compared with DES.

9.
Cardiovasc Revasc Med ; 57: 53-59, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37543502

RESUMEN

BACKGROUND: The magnesium Magmaris scaffold is the latest resorbable technology with low thrombogenicity, short scaffolding time, and almost complete resorption at 12 months (95 %). As compared with stable coronary artery disease (SCAD), acute coronary syndrome (ACS) is associated with increased risk of adverse clinical outcome after percutaneous coronary intervention. We analyzed the data of the Magmaris Multicenter Italian Registry to compare clinical outcomes in SCAD versus ACS patients. METHODS: We evaluated the 24-month rates of target lesion failure (TLF) and scaffold thrombosis (ST). Device implantation procedures were performed according to the manufacturer's recommendations (proper patient/lesion selection, pre-dilatation, proper scaffold sizing, and post-dilatation). Dual antiplatelet therapy was terminated after 12 months. RESULTS: Data from 207 patients (145 SCAD and 62 ACS) were collected from July 2016 to June 2018. The 2-year follow-up compliance was 92.8 % (192 patients). At 2 years, TLF rates were 7.4 % in the SCAD group and 8.8 % in the ACS group (p = 0.7); ST rates were 0 % in the SCAD group and 1.8 % in the ACS group (p = 0.1). CONCLUSION: The 2-year clinical results from the Magmaris Multicenter Italian Registry are favorable in terms of TLF and ST, indicating the safety and effectiveness of the Magmaris scaffold in both SCAD and ACS patients.


Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Trombosis , Humanos , Implantes Absorbibles , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/terapia , Trombosis/etiología , Sistema de Registros , Italia
10.
Int J Cardiol ; 387: 131149, 2023 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-37423566

RESUMEN

BACKGROUND: Drug-coated balloon (DCB) became a potential treatment option for patients with acute coronary syndrome (ACS); however, factors associated with target lesion failure (TLF) remain uncertain. METHODS: This retrospective, multicentre, observational study included consecutive ACS patients who underwent optical coherence tomography (OCT)-guided DCB treatment. Patients were divided into two groups according to the occurrence of TLF, a composite of cardiac death, target vessel-related myocardial infarction, and ischemia-driven target lesion revascularisation. RESULTS: We enrolled 127 patients in this study. During the median follow-up period of 562 (IQR: 342-1164) days, 24 patients (18.9%) experienced TLF, and 103 patients (81.1%) did not. The cumulative 3-year incidence of TLF was 22.0%. The cumulative 3-year incidence of TLF was the lowest in patients with plaque erosion (PE) (7.5%), followed by those with rupture (PR) (26.1%) and calcified nodule (CN) (43.5%). Multivariable Cox regression analysis revealed that plaque morphology was independently associated with TLF on pre-PCI (percutaneous coronary intervention) OCT, and residual thrombus burden (TB) was positively associated with TLF on post-PCI OCT. Further stratification by post-PCI TB revealed a comparable incidence of TLF in patients with PR (4.2%) to that of PE if the culprit lesion had a smaller post-PCI TB than the cut-off value (8.4%). TLF incidence was high in patients with CN, regardless of TB size on post-PCI OCT. CONCLUSIONS: Plaque morphology was strongly associated with TLF for ACS patients after DCB treatment. Residual TB post-PCI might be a key determinant for TLF, especially in patients with PR.


Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Placa Aterosclerótica , Humanos , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/epidemiología , Síndrome Coronario Agudo/cirugía , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Tomografía de Coherencia Óptica/métodos , Estudios Retrospectivos , Angiografía Coronaria/métodos , Resultado del Tratamiento , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/cirugía , Placa Aterosclerótica/etiología , Vasos Coronarios/patología , Enfermedad de la Arteria Coronaria/terapia
11.
Cardiovasc Revasc Med ; 54: 47-56, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37150642

RESUMEN

BACKGROUND: The use of drug-coated balloon in the management of true bifurcation lesions appears to be an attractive option to reduce the rate of stent thrombosis and restenosis particularly at the level of the side branch ostium. We aim to assess the safety and the efficacy of a hybrid approach combining a drug-eluting stent in the main branch and a drug-coated balloon to treat the side branch ostium in patients with de novo true bifurcation. METHODS: From September 2020 to March 2022, 45 patients with a de novo true bifurcation lesion Medina (1.1.1) or Medina (0.1.1) were enrolled. All patients underwent a percutaneous coronary intervention with the hybrid approach. Clinical assessment with functional stress imaging test was scheduled at 6 months. In case of documented ischemia, coronary angiography was performed. The primary endpoint was the composite of target lesion failure at 6 months including cardiac death, target vessel MI or ischemia-driven target lesion revascularization. The secondary endpoints were technical success, defined by performing the percutaneous coronary intervention without an additional drug-eluting stent at the level of the side branch ostium, and clinical success, defined by a technical success associated with the absence of severe complications during in-hospital phase. RESULTS: The immediate results show a technical success of the procedure in the majority of cases (88.9 %) with a low rate of bailout side branch stenting (11.1 %). The clinical success was obtained in 86.7 % and only one patient experienced a severe in-hospital complication. A side branch ostial lesion length > 10 mm was the only independent predictor of clinical failure of the procedure (OR 12.49, 95 % CI 1.17-133.6; p = 0.037). At 6 months, the TLF was low and occurred in 1 patient (2.2 %). No cardiac death was observed. No TVMI was observed. Importantly, at 6 months, no side branch thrombosis was observed. CONCLUSION: The use of a hybrid approach combining a drug-eluting stent in the main branch and a drug-coated balloon in the side branch to treat true bifurcation lesions appears to be safe and efficient with few immediate complications and with satisfactory results at mid-term follow up.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos , Humanos , Stents Liberadores de Fármacos/efectos adversos , Paclitaxel/efectos adversos , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Resultado del Tratamiento , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Reestenosis Coronaria/etiología
12.
Cardiol J ; 30(2): 196-203, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-34490602

RESUMEN

BACKGROUND: Covered coronary stent (CS) implantation is associated with a high risk for in-stent restenosis (ISR) and stent thrombosis (ST). We describe the outcomes after overstenting ("burying") CS using contemporary drug-eluting stents (DES). METHODS: We analyzed short- and long-term outcomes of consecutive patients who had had a CS implanted, which was consecutively covered ("buried") with a third-generation DES. CSs were primarily post-dilated and then covered with a longer DES overlapping the proximal and distal edges of the CS. To ensure optimal stent expansion and appositions, all lesions were post-dilated using adequately sized non-compliant balloons. RESULTS: Between 2015 and 2020, 23 patients (mean age 67 ± 14 years, 74% males) were treated using this novel approach. Reasons for implanting CS included treatment of coronary aneurysms (n = 7; 30%), coronary perforations (n = 13; 57%), and aorto-ostial dissections (n = 3; 13%). All CSs were successfully deployed, and no peri-procedural complications occurred. The median time of follow-up was 24.5 (interquartile range [IQR] 11.7-37.9) months. All patients had a 1-month follow-up (FU) and 19/23 (83%) patients had 12-month FU (FU range 1-60 months). No probable or definite STs occurred, and no cardiovascular deaths were observed. Among patients undergoing angiographic FU (11/23 [48%]), 1/23 showed angiographically significant ISR 6 months post CS implantation. CONCLUSIONS: Burying a coronary CS under a DES appears to be a safe and promising strategy to overcome the limitations of the currently available CS devices, including a relatively high risk for target lesion failure due to ISR and ST.


Asunto(s)
Angioplastia Coronaria con Balón , Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Trombosis , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Stents Liberadores de Fármacos/efectos adversos , Angioplastia Coronaria con Balón/efectos adversos , Angiografía Coronaria/efectos adversos , Resultado del Tratamiento , Factores de Riesgo , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Stents/efectos adversos , Trombosis/etiología , Intervención Coronaria Percutánea/efectos adversos
13.
Catheter Cardiovasc Interv ; 101(1): 13-21, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378691

RESUMEN

OBJECTIVES: To compare the efficacy and safety of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (O-SES) in patients with and without acute coronary syndrome (ACS) included in the SORT OUT X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with ACS when compared to patients without ACS. Whether the results from the SORT OUT X study apply to patients with and without ACS remains unknown. METHODS: In total, 3146 patients were randomized to stent implantation with DTS (n = 1578; ACS: n = 856) or O-SES (n = 1568; ACS: n = 854). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was higher in the DTS group compared to the O-SES group, both among patients with ACS (6.7% vs. 4.1%; incidence rate ratio: 1.65 [95% confidence interval, CI: 1.08-2.52]) and without ACS (6.0% vs. 3.2%; incidence rate ratio: 1.88 [95% CI: 1.13-3.14]). The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without ACS CONCLUSION: Compared to the O-SES, the DTS was associated with a higher risk of TLF at 12 months in patients with and without ACS. The differences were mainly explained by higher rates of TLR.


Asunto(s)
Síndrome Coronario Agudo , Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Sirolimus/efectos adversos , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/complicaciones , Enfermedad de la Arteria Coronaria/terapia , Factores de Riesgo , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Implantes Absorbibles , Fármacos Cardiovasculares/efectos adversos , Factores de Tiempo , Diseño de Prótesis , Infarto del Miocardio/etiología , Stents Liberadores de Fármacos/efectos adversos
14.
J Cardiol ; 81(1): 76-82, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36163312

RESUMEN

BACKGROUND: This head-to-head, multicenter, randomized trial investigated the safety and efficacy of Restore (Cardionovum, Bonn, Germany) drug-coated balloon (DCB) angioplasty in an Asian patient population with coronary drug-eluting stent in-stent restenosis (DES-ISR). METHODS: A total of 240 patients with coronary DES-ISR were treated with Restore DCB or with SeQuent® Please (Braun, Melsungen, Germany) DCB. This trial used nine-month in-segment late lumen loss (LL) as the primary endpoint. Secondary endpoints included two-year clinical event rates. RESULTS: Patient, lesion, and procedural characteristics in both treatment groups were similar. Nine-month in-segment LL was 0.38 ±â€¯0.50 mm with Restore vs. 0.35 ±â€¯0.47 mm with SeQuent® Please (p for non-inferiority = 0.02). The two-year follow-up rates were 95.8 % (115/120) in the Restore group and 94.2 % (113/120) in the SeQuent® Please group. Both groups had similar one- and two-year target lesion failure (TLF) rates (13.3 % vs. 12.6 %; p = 0.87 at one year, 14.8 % vs. 15.0 %; p = 1.0 at two years). Moreover, the all-cause mortality and myocardial infarction rates were 0 and 3.5 % (4/120) in the Restore group and 0.9 % (1/120) and 3.5 % (4/120) in the SeQuent® Please group, respectively. Additional analyzing of vessel quantitative flow ratio (QFR) did also show noninferior outcomes for one explicit treatment bunch. CONCLUSIONS: The two-year follow-up indicated sustained long-term clinical safety and efficacy for both devices on the basis of QFR value.


Asunto(s)
Fármacos Cardiovasculares , Reestenosis Coronaria , Stents Liberadores de Fármacos , Humanos , Reestenosis Coronaria/terapia , Reestenosis Coronaria/cirugía , Stents Liberadores de Fármacos/efectos adversos , Materiales Biocompatibles Revestidos , Paclitaxel , Resultado del Tratamiento , Factores de Tiempo
15.
Rev Cardiovasc Med ; 24(2): 53, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-39077417

RESUMEN

Background: In patients undergoing percutaneous coronary intervention (PCI), drug eluting stents (DES) are currently the standard of care. Stent design and alloy composition, biocompatibility of the drug-eluting polymer coating, the antiproliferative agent properties and release are the three main characteristics that affects DES performance. Cre8 (Alvimedica, Istanbul, Turkey) is a polymer-free amphilimus-eluting stents (PF-AES). In this study, we aimed to investigate the clinical efficacy and safety of Cre8 DES in daily cardiology practice. Methods: Patients presenting with chronic coronary syndrome (CCS) or acute coronary syndrome (ACS) including unstable angina pectoris (USAP), myocardial infarction with and without ST-segment elevation and treated with PCI using Cre8 DES between December 2015 and 2016 were retrospectively analyzed in this study. Results: Between December 2015 and 2016, 808 lesions of 664 patients treated with Cre8 DES in a single center were included in this retrospective analysis. The mean age of study group was 60 years (between 33 and 93 years) and were predominantly consisting of male patients (79.4%). The median follow-up duration was 487 days (min: 30 days, max: 919 days) and two-thirds of all patients presented with ACS. The culprit lesion was on left anterior descending artery (LAD) (40.5%) and right coronary artery (RCA) (25.9%) in most of the patients. The procedural success rate was 97.3%. Most of the lesions were type B1 (40.6%) according to American College of Cardiology/American Heart Association (ACC/AHA) coronary lesion classification. The device oriented primary end-point defined as target lesion failure (TLF) occurred in 52 (6.4%) of 808 lesions. The primary safety end-point was cardiac death in 20 patients (3.0%) and target vessel myocardial infarction in 2 patients (0.3%). Target vessel revascularization (TVR) occurred in 29 patients (4.4%) as primary safety endpoint. Multivariable logistic regression analysis revealed diabetes mellitus and ejection fraction as the predictors of mortality and device oriented primary end-point. Conclusions: This trial revealed clinical efficacy and safety of Cre8 stents in real world practice. Device oriented primary end points were similar with previous studies which are randomized, open label in nature and showed the efficacy and safety of Cre8 stent towards latest generation DES.

16.
Rev Cardiovasc Med ; 24(8): 221, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39076703

RESUMEN

Background: The DynamX Novolimus-Eluting Coronary Bioadaptor System ( DynamX ® Bioadaptor) has uncaging elements that disengage after the resorption of the polymer coating, aiming to restore vessel function in the treated segment and to avoid long-term adverse outcomes associated with the permanent caging of the coronary artery seen with conventional stenting. Methods: This prospective, multicenter, single-arm first-in-human study enrolled 50 patients in Belgium and Italy who were treated with the DynamX Bioadaptor. Eligible patients had de novo lesions in coronary arteries measuring between 2.5 and 3.5 mm in diameter and ≤ 24 mm in length. Clinical follow-up was performed up to 36 months. This analysis includes the intention-to-treat population and is based on data available. The preclinical studies include optical coherence tomography (OCT) analyses of 5 DynamX Bioadaptors implanted in 3 mini Yucatan pigs (at 3, 12 and 24 months), and assessment of smooth muscle cell gene expression profile in 8 pigs of which each was implanted with the DynamX Bioadaptor and the Xience drug-eluting stent. To assess the gene expression profile by quantitative real-time polymerase chain reaction, animals were sacrificed at 3, 6, 9 and 12 months. Results: Target lesion failure at 36 months was 8.7% (4/46), consisting of one clinically-driven target lesion revascularization and 3 cardiac deaths (all site-reported to be unrelated to the device or procedure). There were no additional target vessel revascularization and no definite or probable scaffold thrombosis. Preclinical data confirmed late lumen enlargement (from 7.02 ± 1.31 mm 2 at baseline to 8.46 ± 1.31 mm 2 at 24 months) and identified an increased expression of contractile genes around 9 months compared to a conventional drug-eluting stent. Conclusions: The DynamX Bioadaptor demonstrated very good 36-month clinical outcomes, highlighted by the absence of target-vessel myocardial infarction and definite or probable device thrombosis, and only one target lesion revascularization up to 36 months. These data are supported by preclinical studies that showed late lumen enlargement by OCT and an increased expression of contractile genes around 9 months compared to conventional drug-eluting stents, indicating faster vessel healing. Larger clinical studies are necessary to compare outcomes against contemporary drug-eluting stents. Clinical Trial Registration: https://clinicaltrials.gov/: NCT03429894.

17.
J Am Heart Assoc ; 11(24): e025275, 2022 12 20.
Artículo en Inglés | MEDLINE | ID: mdl-36515253

RESUMEN

Background Use of the modified American College of Cardiology (ACC)/American Heart Association (AHA) lesion classification as a prognostic tool to predict short- and long-term clinical outcomes after percutaneous coronary intervention in the modern drug-eluting stent era is uncertain. Methods and Results Patient-level data from 7 prospective, randomized trials were pooled. Clinical outcomes of patients undergoing single lesion percutaneous coronary intervention with second-generation drug-eluting stent were analyzed according to modified ACC/AHA lesion class. The primary end point was target lesion failure (TLF: composite of cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization). Clinical outcomes to 5 years were compared between patients treated for noncomplex (class A/B1) versus complex (class B2/C) lesions. Eight thousand five hundred sixteen patients (age 63.1±10.8 years, 70.5% male) were analyzed. Lesions were classified as A, B1, B2, and C in 7.9%, 28.5%, 33.7%, and 30.0% of cases, respectively. Target lesion failure was higher in patients undergoing percutaneous coronary intervention of complex versus noncomplex lesions at 30 days (2.0% versus 1.1%, P=0.004), at 1 year (4.6% versus 3.0%, P=0.0005), and at 5 years (12.4% versus 9.2%, P=0.0001). By multivariable analysis, treatment of ACC/AHA class B2/C lesions was significantly associated with higher rate of 5-year target lesion failure (adjusted hazard ratio, 1.39 [95% CI, 1.17-1.64], P=0.0001) driven by significantly higher rates of target vessel myocardial infarction and ischemia-driven target lesion revascularization. Conclusions In this pooled large-scale analysis, treating complex compared with noncomplex lesions according to the modified ACC/AHA classification with second-generation drug-eluting stent was associated with worse 5-year clinical outcomes. This historical classification system may be useful in the contemporary era for predicting early and late outcomes following percutaneous coronary intervention.


Asunto(s)
Cardiología , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Resultado del Tratamiento , Estudios Prospectivos , Factores de Riesgo , Ensayos Clínicos Controlados Aleatorios como Asunto , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/etiología
18.
Cardiovasc Diabetol ; 21(1): 220, 2022 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-36307791

RESUMEN

BACKGROUND: Diabetes mellitus (DM) and cardiovascular diseases often co-exist. Today, percutaneous coronary intervention (PCI) is the preferred revascularization procedure for majority of patients with coronary artery disease. Polymer-free amphilimus-eluting stents (AES) represent a novel elution technology in the current era of drug-eluting stents. In this analysis, we aimed to systematically compare the cardiovascular outcomes which are associated with polymer-free amphilimus-eluting stents (AES) versus the durable polymer zotarolimus-eluting stents (ZES) for the treatment of patients with DM. METHODS: Http://www. CLINICALTRIALS: gov, EMBASE, Web of Science, MEDLINE, Cochrane database and Google Scholar were searched for publications comparing polymer-free AES versus durable polymer ZES in patients with DM. Selective cardiovascular outcomes were assessed. Statistical analysis was carried out by the latest version of the RevMan software. Risk ratio (RR) with 95% confidence interval (CI) was used to represent the data analysis. RESULTS: Four studies with a total number of 1795 participants with DM whereby 912 patients were assigned to be revascularized by the polymer-free AES and 883 patients were assigned to be revascularized by the durable polymer ZES were included in this analysis. In patients with DM, at one year, polymer-free AES were associated with significantly lower risk of major adverse cardiac events (MACEs) (RR: 0.69, 95% CI: 0.54-0.88; P = 0.002) and target lesion failure (TLF) (RR: 0.66, 95% CI: 0.48-0.91; P = 0.01) compared to durable polymer ZES. However, there was no significant change in all-cause mortality (RR: 0.79, 95% CI: 0.51-1.22; P = 0.28), cardiac death and the other cardiovascular outcomes. Similar risk of total stent thrombosis (RR: 1.13, 95% CI: 0.60-2.13; P = 0.70), including definite stent thrombosis (RR: 1.12, 95% CI: 0.38-3.31; P = 0.84), probable stent thrombosis (RR: 0.87, 95% CI: 0.37-2.09; P = 0.76), possible stent thrombosis (RR: 1.19, 95% CI: 0.50-2.87; P = 0.69) and late stent thrombosis (RR: 1.00, 95% CI: 0.17-5.72; P = 1.00) as between polymer-free AES and durable polymer ZES in patients with DM. CONCLUSIONS: At 1 year follow-up, polymer-free AES were associated with significantly lower MACEs and TLF compared to durable polymer ZES in these patients with DM, without any increase in mortality, stent thrombosis and other cardiovascular outcomes. However, this analysis is only based on a follow-up time period of one year, therefore, future research should focus on the long term follow-up time period.


Asunto(s)
Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Fármacos Cardiovasculares/efectos adversos , Factores de Riesgo , Diseño de Prótesis , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus/inducido químicamente , Resultado del Tratamiento
19.
Front Cardiovasc Med ; 9: 910313, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36304537

RESUMEN

Background: Provisional stenting (PS) is the main treatment for a majority of coronary bifurcation lesion and includes PS with 1-stent and PS with 2-stent. However, the treatment difference between PS with 1-stent and with 2-stent remains unclear in patients with the acute coronary syndrome (ACS) and coronary bifurcation lesions. Materials and methods: Overall, 820 ACS patients with Medina 1,1,1 or 0,1,1 coronary bifurcation lesion who had completed 3-year follow-up were included and assigned to the PS with 1-stent (n = 519) or the PS with 2-stent (n = 301) according to the use of final stenting technique. The primary endpoint was the target lesion failure (TLF) at 3 years since stenting procedures. Results: At 3-year follow-up, TLF occurred in 85 (16.4%) patients in the PS with 1-stent group and 69 (22.9%) in the PS with 2-stent group (hazard ratio [HR] 1.52, 95% confidence interval [CI] 1.06-2.17, p = 0.021), mainly driven by a higher rate of target lesion revascularization (TLR) in the PS with 2-stent group (13.0% vs. 8.3%, HR 1.65, 95% CI 1.04-2.61, p = 0.033). Complex bifurcations, side branch (SB) pretreatment, intravascular imaging guidance, and hyperlipidemia were the four predictors for 3-year TLF. SB pretreatment was associated with increased 3-year TLR, leading to an extremely higher 3-year TLF. Conclusion: Provisional with 2-stent for patients with ACS is associated with a higher rate of 3-year TLF, mainly due to increased requirement of revascularization. SB pretreatment should be avoided for simple bifurcation lesion.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA