Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Neuroendovasc Ther ; 15(10): 681-687, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-37502376

RESUMEN

Objective: We report the usefulness and pitfalls of coil embolization using the T or half T-stent technique for aneurysms located at internal carotid artery-posterior communicating artery (ICA-P-com) bifurcation in which the neck is wide and the P-com must be kept patent due to it being the fetal-type with a hypoplastic P1 segment. Case Presentations: Two cases were treated using the T-stent technique and two were treated using the half T-stent technique. The average age of the patients was 70.3 years and all were females. One aneurysm ruptured. The average size of aneurysms and neck was 12 mm and 8.5 mm, respectively, in the T-stent group, and 7.4 mm and 6.7 mm, respectively, in the half T-stent group. An S- or pigtail-shaped microcatheter (MC) was used to navigate into the P-com. Stent deployment was successful in all the cases. Retreatment was required in one case treated using the T-stent technique due to major recurrence. Conclusion: T or half T-stent-assisted coil embolization can be an alternative endovascular treatment method for wide-necked ICA-P-com aneurysms in which the P-com must be kept patent due to it being the fetal-type with a hypoplastic P1 segment.

2.
J Neuroendovasc Ther ; 15(6): 396-403, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-37502421

RESUMEN

Objective: We report a case of a wide-necked internal carotid-posterior communicating (IC-Pcom) artery aneurysm treated by the retrograde T-stent technique in which a stent was also placed in the Pcom artery via the posterior circulation. Case Presentation: A 35-year-old woman was diagnosed with an unruptured right IC-Pcom artery aneurysm (maximum diameter: 11 mm, neck diameter: 8.5 mm) during a detailed examination for vertigo. The Pcom artery (2.1 mm) branched from the aneurysmal dome. A microcatheter was guided in retrograde via the Pcom artery from the posterior circulation. A low-profile visualized intraluminal support (LVIS) Jr. 2.5 mm × 17 mm was deployed from the internal carotid artery (ICA) to the Pcom artery, and then, an LVIS 4.5 mm × 23 mm was deployed while pressing the flare of the LVIS Jr. protruding into the ICA. T configuration stenting was completed, and the coil was inserted as tightly as possible. Conclusion: The retrograde T-stent technique, which has the advantage of optimal stent positioning, is useful for preserving a Pcom artery branching from the aneurysmal dome.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA