Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 379
Filtrar
1.
North Clin Istanb ; 11(4): 271-276, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39165701

RESUMEN

OBJECTIVE: The purpose of this study was to assess the influence of latanoprost on choroidal thickness in patients with newly diagnosed primary open-angle glaucoma using Swept-Source Optical Coherence Tomography (SS-OCT). METHODS: The retrospective, non-randomized study comprised 40 newly diagnosed primary open-angle glaucoma patients receiving latanoprost therapy (Group 1). Additionally, 40 age- and sex-matched healthy subjects served as the control group (Group 2). Using SS-OCT, measurements of subfoveal, horizontal temporal, and horizontal nasal quadrants choroidal thickness, as well as intraocular pressure (IOP) and retinal nerve fiber layer (RNFL) thickness values, were collected at baseline and after 1 month for both groups. RESULTS: The mean age was 39.8±4.15 years (range: 18-45 years) in group 1 and 41.67±7.95 years (range: 18-45 years) in group 2 (p>0.05). The mean choroidal thickness in the subfoveal area, horizontal temporal quadrant, and horizontal nasal quadrant prior to latanoprost therapy were 263.57±84.23 µm, 233.05±80.08 µm, and 219.52±83.28 µm in the group 1 whereas 278.9±93.88 µm, 243.8±73.37 µm and 209.85±92.92 µm in the group 2. After latanoprost therapy, the mean choroidal thickness in the subfoveal area, horizontal temporal quadrant, and horizontal nasal quadrant changed significantly to 299.77±41.29 µm, 269.9±43.80 µm, and 261.32±45.60 µm in the group 1 (p=0.02, p=0.016, and p=0.012, respectively) (Table 1). However, the mean choroidal thickness in the subfoveal area, horizontal temporal quadrant and horizontal nasal quadrant in group 2 changed not significant and was 279.25±103.37 µm, 246.42±87.07 µm and 203.62±106.74 µm, respectively (p=0.4, p=0.5 and p=0.9, respectively). The mean IOP decreased significantly in group 1 (p=0.000) but did not change significantly in group 2 (p=0.153). There was no difference in RNFL thickness values at baseline and 1 st month in group 1 and group 2 (p>0.05). CONCLUSION: Topical latanoprost may increase choroidal thickness. Swept Source-OCT may contribute to our understanding of the actions of latanoprost on choroidal thickness.

2.
Int J Ophthalmol ; 17(8): 1437-1446, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39156774

RESUMEN

AIM: To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography (SS-OCT) and Scheimpflug tomography in patients diagnosed with cataract. METHODS: This prospective case series was conducted at Tianjin Medical University Eye Hospital. In total, 212 eyes from 212 patients scheduled for phacoemulsification were included. Eyes were evaluated preoperatively using two SS-OCT devices (IOLMaster700 and CASIA2) and Scheimpflug tomography (Pentacam). Central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AQD), white-to-white distance (WTW), flat simulated keratometry (Kf), steep simulated keratometry (Ks), mean keratometry (Km), and total corneal keratometry (TKm) were measured. Intraclass correlation coefficient (ICC), 95% confidence intervals (CI) and limits of agreement (LoA) widths were conducted to assess differences and correlations between devices. RESULTS: All parameters, except for Ks, were significantly different. Pairwise comparison revealed no significant differences between keratometry obtained by IOLMaster 700 and Pentacam. LoA widths of all paired comparisons for Ks were >0.80 D. Except for WTW between IOLMaster 700 and CASIA2 and between CASIA2 and Pentacam, other Pearson's coefficients between devices showed a strong correlation (all r>0.95). The ICC of WTW (ICC=0.438, 95%CI 0.167-0.625) showed poor reliability. The reliability of CCT, ACD, and AQD was excellent (all ICC>0.95), whereas that of TKm was good (ICC=0.827, 95%CI 0.221-0.939). A significant linear correlation was also observed among devices. CONCLUSION: The ocular parameters derived from the use of IOLMaster700, CASIA2, and Pentacam exhibit significant discrepancies; as such, measurements from these devices should not be deemed as interchangeable.

3.
Am J Ophthalmol Case Rep ; 36: 102130, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39156907

RESUMEN

Purpose: To report longitudinal changes in choroidal thickness and the choroidal vasculature using SS-OCT imaging in a patient with superior ophthalmic vein thrombosis (SOVT). Observations: In a 93-year-old woman with a left-sided SOVT, the choroid in the left eye was thickened and the choroidal vessels were dilated both superiorly and inferiorly, with greater changes evident in the inferotemporal region of the choroid. After the superior ophthalmic vein was decompressed, a decrease in the choroidal thickness and choroidal vessel dilatation was observed both superiorly and inferiorly. Conclusions and importance: In an eye with thrombosis of the superior ophthalmic vein, longitudinal SS-OCT choroidal imaging showed a greater increase in choroidal thickness and choroidal vessel dilation away from the obstructed quadrant, which improved after treatment. These observations associated with outflow obstruction may be applicable to other choroidal diseases characterized by venous overload.

4.
Photodiagnosis Photodyn Ther ; 49: 104317, 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39181492

RESUMEN

PURPOSE: To determine the existence of differences in the retinal microcirculation of dominant and non-dominant eyes, as well as of interocular differences in macular microcirculation, using swept-source optical coherence tomography angiography (OCTA). METHODS: In total, 122 eyes of 61 individuals were enrolled in this cross-sectional study. Measurements were taken using the swept-source optical coherence tomography Triton device (Topcon Corp, Tokyo, Japan) coupled with non-invasive OCTA technology. Macular perfusion parameters were assessed, including superficial vascular complex, vascular density of the deep vascular complex, vascular density of the choriocapillaris vascular complex, superficial foveal avascular zone and deep foveal avascular zone. Ocular dominance was determined among individuals with healthy eyes using the hole-in-the-card test. RESULTS: Ocular dominance was found in 68.9 % of right eyes and 31.1 % of left eyes. The mean age of the subjects was 34.45 ± 16.48 years (range: 18-73 years). We found that 16 (30.76 %) males and 22 (31.42 %) females had left-eye dominance (p > 0.05). None of the OCTA parameters differed between the eyes based on dominance (p > 0.05). Central macular thickness and sub-foveal choroidal thickness did not show significant differences (p > 0.05). When comparing interocular parameters, a significant difference was observed only in the inferior sector of the superficial vascular complex (p = 0.04). CONCLUSION: There was no significant difference in OCTA parameters between dominant and non-dominant eyes. There was no predominant interocular difference in the measurements.

5.
Int Ophthalmol ; 44(1): 318, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38972925

RESUMEN

PURPOSE: This study aims to introduce the coefficient of spatial variance of choroidal thickness to describe the choroidal variation and investigate its associated factors in healthy eyes. METHODS: This retrospective cross-sectional study included 1031 eyes from 1031 subjects who received a swept-source optical coherence tomography examination. The mean choroidal thickness in the macular 6 × 6 mm region and 900 subregions of 0.2 × 0.2 mm were computed using the embedded algorithm. Before analysis, potential segmentation and magnification errors were corrected. The coefficient of spatial variance was defined as the standard deviation divided by the mean (multiplied by 100%) of the choroidal thicknesses across 900 grids. Potential factors associated with the coefficient of spatial variance were assessed using multiple linear regression. RESULTS: The mean choroidal thickness of the entire 6 × 6 mm macular region was 204.50 ± 72.88 µm. The mean coefficient of spatial variance was 26.58 ± 8.24%, ranging from 11.00 to 61.58%. Statistical analysis revealed that the means choroidal thickness (ß = - 0.08, R2 = 0.42, p < 0.001) and anterior chamber depth (ß = - 2.39, R2 = 0.05, p = 0.06) were associated with the coefficient of spatial variance. CONCLUSION: Our study first incorporated the coefficient of spatial variance to represent the spatial variation of the choroidal thickness and observed that the greater thinning of the choroid is correlated with a more pronounced spatial variation.


Asunto(s)
Coroides , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Coroides/diagnóstico por imagen , Coroides/anatomía & histología , Estudios Retrospectivos , Estudios Transversales , Masculino , Femenino , Persona de Mediana Edad , Adulto , Anciano , Voluntarios Sanos , Adulto Joven
6.
Medicina (Kaunas) ; 60(7)2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-39064485

RESUMEN

Background and Objectives: To compare the biometry of eyes obtained with two swept-source optical coherence tomography-based biometers-Argos (A), using an individual refractive index, and IOLMaster 700 (IM), using an equivalent refractive index-for all structures. Materials and Methods: The biometry of 105 eyes of 105 patients before cataracts were analyzed in this study. Parameters such as axial length (AL), anterior chamber depth (ACD), and lens thickness (LT) were compared from both devices. According to the axial length measurements, patients were divided into three groups, as follows: group 1-short eyes (AL < 22.5 mm), group 2-average eyes (22.5 ≤ AL ≤ 26.0 mm), and group 3-long eyes (AL > 26.0 mm). Results: The correlation coefficiency among all compared parameters varies from R = 0.92 to R = 1.00, indicating excellent reliability of IM and A. A statistical significance in axial length was indicated in the group of short eyes (n = 26)-mean AL (A) 21.90 mm (±0.59 mm) vs. AL (IM) 21.8 mm ± (0.61 mm) (p < 0.001)-and in the group of long eyes (n = 5)-mean AL (A) 27.95 mm (±2.62 mm) vs. mean AL (IM) 28.10 mm (±2.64) (p < 0.05). In the group of average eyes (n = 74), outcomes were similar-mean AL (A) 23.56 mm (±0.70 mm) vs. mean AL (IM) 23,56 mm (±0.71 mm) (p > 0.05). The anterior chamber depth measurements were higher when obtained with Argos than with IOLMaster 700-mean ACD (A) 3.06 mm (±0.48 mm) vs. mean ACD (IM) 2.92 mm (±0.46) p < 0.001. There was no statistical significance in mean LT-mean LT (A) 4.75 mm (±0.46 mm) vs. mean LT (IM) 4.72 mm (±0.44 mm) (p = 0.054). The biometry of one eye with dense cataracts could be measured only with Argos, using the Enhanced Retinal Visualization mode. Conclusions: Axial length measurements from both devices were different in the groups of short and long eyes, but were comparable in the group of average eyes. The anterior chamber depth values obtained with Argos were higher than the measurements acquired with IOLMaster 700. These differences may be particularly important when selecting IOLs for patients with extreme AL values.


Asunto(s)
Biometría , Catarata , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Biometría/métodos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Longitud Axial del Ojo/diagnóstico por imagen , Reproducibilidad de los Resultados , Cámara Anterior/diagnóstico por imagen , Cámara Anterior/anatomía & histología , Anciano de 80 o más Años
7.
Saudi J Ophthalmol ; 38(2): 101-111, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38988788

RESUMEN

PURPOSE: To assess central and peripheral retinal and choroidal diseases using ultra-widefield (UWF) fundus imaging in combination with navigated central and peripheral cross-sectional and three-dimensional (3D) swept source optical coherence tomography (SS-OCT) scans. METHODS: Retrospective study involving 332 consecutive patients, with a nearly equal distribution of males and females. The mean age of patients was 52 years (range 18-92 years). Average refractive error was -3.80 D (range +7.75 to -20.75 D). RESULTS: The observations in this study demonstrate the efficacy of peripheral navigated SS-OCT in assessing various ocular conditions. The technology provides high-quality images of the peripheral vitreous, vitreoretinal interface, retina, and choroid, enabling visualization of vitreous floaters and opacities, retinal holes and tears, pigmented lesions, and peripheral retinal degenerations. 3D OCT scans enhance the visualization of these abnormalities and improve diagnostic and therapeutic decisions. CONCLUSION: Navigated central and peripheral cross-sectional and 3D SS-OCT scans offer significant complementary benefits in the assessment and management of retinal diseases. Their addition to UWF imaging provides a comprehensive view of central and peripheral ocular structures, aiding in early detection, precise anatomical measurements, and objective monitoring of disease progression. In addition, this technology serves as a valuable tool for patient education, a teaching tool for trainees, and documentation for medico-legal purposes.

8.
Ophthalmol Ther ; 13(9): 2381-2391, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39020238

RESUMEN

INTRODUCTION: The purpose of the study was to explore the possible correlations between the anterior segment parameters derived from anterior segment swept-source optical coherence tomography (AS-SS-OCT) with the surgically induced corneal astigmatism (CSIA) calculated from total keratometry (TK) measured by AS-SS-OCT. METHODS: Seventy-one eyes of 67 patients with age-related cataract who underwent phacoemulsification combined with intraocular lens implantation with 2.2-mm incision were included. The CSIA values were calculated from anterior keratometry (CSIAKant) and TK (CSIATK) measured by AS-SS-OCT, respectively. Hotelling's T2 test was used to evaluate the difference. The correlation of CSIA with various parameters derived from AS-SS-OCT was tested with the Spearman correlation coefficient. RESULTS: The centroid of CSIAKant and of CSIATK were 0.31 ± 0.55 D @ 54° and 0.41 ± 0.59 D @ 51°, with no significant difference (F = 1.283, p = 0.281, Hotelling's T2). The mean absolute CSIAKant and CSIATK were 0.58 ± 0.24 D and 0.65 ± 0.28 D. Spearman test showed that the magnitude of CSIAKant was negatively correlated with preoperative peripheral corneal thickness (PCT, p = 0.045) and the magnitude of anterior keratometry (p = 0.044). The magnitude of CSIATK was negatively correlated with preoperative central corneal thickness (CCT, p = 0.003) and preoperative PCT (p = 0.015). CONCLUSIONS: The increased thickness of the peripheral cornea is correlated with the decrease in the magnitude of the CSIA. The correlation we identified between the corneal thickness and the CSIA indicated that certain preoperative parameters should be considered for the prediction of CSIA for a more precise refractive outcome.

9.
Lasers Med Sci ; 39(1): 150, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38836959

RESUMEN

PURPOSE: To investigate the swept-source optical coherence tomography (SS-OCT) and SS-OCT angiography (SS-OCTA) findings in circumscribed choroidal hemangioma (CCH) before and after treatment with transpupillary thermotherapy (TTT). METHODS: The clinical records of 21 eyes having CCH imaged with SS-OCT/SS-OCTA between September 2018 and December 2022 were evaluated. RESULTS: SS-OCT examination in CCH showed dome-shaped appearance (100%), choroidal shadowing (100%), expansion of choroidal structures (100%), subretinal fluid (66.7%), intraretinal edema/schisis (33.3%), retinal pigment epithelium (RPE) atrophy (19.0%), hyperreflective dots (19.0%), and epiretinal membrane (4.8%). Internal arborizing tumor vessels showing hyperreflectivity were observed in the choriocapillaris slab on SS-OCTA in all eyes. In the deep capillary plexus (DCP), flow void changes were seen in 7 eyes with intraretinal schisis/cystoid macular edema. Four CCHs > 2 mm in thickness showed outer retinal involvement due to unmasking of flow in intratumoral vessels related to RPE atrophy. Following TTT/indocyanine green-enhanced TTT (ICG-TTT) of CCH, SS-OCT findings included total/partial resolution of subretinal fluid (57.1%), complete/partial regression of the tumor (52.4%), and RPE atrophy (33.3%). After treatment; loss of choriocapillaris, decrease in tumor vascularity together with increase in the fibrous component and flow void areas were detected on SS-OCTA. CONCLUSIONS: SS-OCT/SS-OCTA are useful non-invasive tools for imaging the structural/vascular changes in CCHs managed with TTT or ICG-TTT. On SS-OCTA, hyporeflective spaces localizing to edema/schisis in the DCP and arborizing tumor vessels within a hyporeflective stromal background in the choriocapillaris slab were observed. After TTT/ICG-TTT, a decrease in tumor vessels and an increase in the fibrous component and flow-void areas inside the CCH were detected on SS-OCTA.


Asunto(s)
Neoplasias de la Coroides , Hemangioma , Hipertermia Inducida , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Neoplasias de la Coroides/terapia , Neoplasias de la Coroides/diagnóstico por imagen , Neoplasias de la Coroides/patología , Femenino , Persona de Mediana Edad , Masculino , Hemangioma/terapia , Hemangioma/diagnóstico por imagen , Hemangioma/patología , Adulto , Hipertermia Inducida/métodos , Anciano , Angiografía con Fluoresceína/métodos , Estudios Retrospectivos , Coroides/diagnóstico por imagen , Coroides/irrigación sanguínea , Coroides/patología
10.
Arch Oral Biol ; 165: 106009, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38838513

RESUMEN

OBJECTIVE: The objective was to measure the thickness of Streptococcus mutans (S. mutans) biofilms forming in an oral biofilm reactor (OBR) by using a noninvasive swept-source optical coherence tomography (SS-OCT) system at every 4 h time interval until 20 h and analyze the correlations with the amounts of biofilms. METHODS: S. mutans biofilms were formed on square-shaped bovine enamel blocks inside an OBR. Biofilms were analyzed at every 4 h stage (4 h, 8 h, 12 h, 16 h and 20 h) using a SS-OCT system and a laser scanning confocal microscope (LSCM). The amounts of biofilms were measured at each stage by separating the water insoluble glucan (WIG) and bacterial cells. Co-relationships between the SS-OCT measured biofilm thickness and the amounts of adhered biofilms were analyzed. RESULTS: The thickness of biofilms detected on SS-OCT images at 4 h stage was 0.059 ± 0.029 (Av ± SD) mm which increased time-dependently in a linear fashion after 8 h stage and reached to 0.435 ± 0.159 mm at 20 h stage and the correlation coefficient was about 0.89. The amounts of biofilms; bacterial optical density (OD) and WIG concentration increased time-dependently were 0.035 ± 0.008 / mm2 and 10.328 ± 2.492 µg/ mm2 respectively at 20 h stage. Correlation coefficients of 0.66 between 'the amounts of bacteria' and 'biofilm thickness on OCT' and 0.67 between 'the amounts of WIG' and 'biofilm thickness on OCT' were obtained, suggesting that there was a relatively positive correlation between them. CONCLUSION: The SS-OCT can be a useful tool to measure time-dependent growth of biofilms. Further studies are needed in order to assess biofilms using SS-OCT more accurately.


Asunto(s)
Biopelículas , Esmalte Dental , Microscopía Confocal , Streptococcus mutans , Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Bovinos , Animales , Streptococcus mutans/fisiología , Microscopía Confocal/métodos , Esmalte Dental/microbiología , Técnicas In Vitro , Caries Dental/microbiología , Caries Dental/diagnóstico por imagen , Factores de Tiempo
11.
BMC Ophthalmol ; 24(1): 259, 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38880899

RESUMEN

BACKGROUND: The anatomic structure of the anterior chamber (AC) helps to explain differences in refractive status in school-aged children and is closely associated with primary angle closure (PAC). The aim of this study was to quantify and analyze the anterior chamber and angle (ACA) characteristics in Chinese children with different refractive status by swept-source optical coherence tomography (SS-OCT). METHODS: In a cross-sectional observational study, 383 children from two primary schools in Shandong Province, China, underwent a complete ophthalmic examination. First, the anterior chamber depth (ACD), anterior chamber width (ACW), angle-opening distance (AOD), and trabecular-iris space area (TISA) were evaluated automatically using a CASIA2 imaging device. AOD and TISA were measured at 500, 750 µm nasal (N1 and N2, respectively), and temporal (T1 and T2, respectively) to the scleral spur (SS). Cycloplegic refraction and axial length (AL) were then measured. According to spherical equivalent refraction (SER), the children were assigned to hyperopic (SER > 0.50D), emmetropic (-0.50D < SER ≤ 0.50D), and myopic groups (SER ≤ -0.50D). RESULTS: Out of the 383 children, 349 healthy children (160 girls) with a mean age of 8.23 ± 1.06 years (range: 6-11 years) were included. The mean SER and AL were - 0.10 ± 1.57D and 23.44 ± 0.95 mm, respectively. The mean ACD and ACW were 3.17 ± 0.24 mm and 11.69 ± 0.43 mm. The mean AOD were 0.72 ± 0.25, 0.63 ± 0.22 mm at N1, T1, and 0.98 ± 0.30, 0.84 ± 0.27 mm at N2, T2. The mean TISA were 0.24 ± 0.09, 0.22 ± 0.09mm2 at N1, T1, and 0.46 ± 0.16, 0.40 ± 0.14mm2 at N2, T2. The myopic group had the deepest AC and the widest angle. Compared with boys, girls had shorter AL, shallower ACD, narrower ACW, and ACA (all p < 0.05). By Pearson's correlation analysis, SER was negatively associated with ACD, AOD, and TISA. AL was positively associated with ACD, ACW, AOD, and TISA. In the multiple regression analysis, AOD and TISA were associated with deeper ACD, narrower ACW, and longer AL. CONCLUSION: In primary school students, the myopic eyes have deeper AC and wider angle. ACD, ACW, AOD, and TISA all increase with axial elongation. ACA is highly correlated with deeper ACD.


Asunto(s)
Cámara Anterior , Refracción Ocular , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Estudios Transversales , Niño , Femenino , Masculino , Cámara Anterior/diagnóstico por imagen , Cámara Anterior/patología , China/epidemiología , Refracción Ocular/fisiología , Glaucoma de Ángulo Cerrado/fisiopatología , Glaucoma de Ángulo Cerrado/diagnóstico , Glaucoma de Ángulo Cerrado/etnología , Errores de Refracción/fisiopatología , Pueblos del Este de Asia
12.
Heliyon ; 10(9): e29780, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38699005

RESUMEN

Objective: To evaluate and compare the magnitude of intraocular lens (IOL) decentration and tilt following conventional and femtosecond laser-assisted cataract surgery (FLACS) using swept-source anterior optical coherence tomography (SS-OCT). Methods: In this retrospective observational study, we enrolled patients who underwent conventional cataract surgery or FLACS with the implantation of hydrophobic 1-piece monofocal IOL. The magnitude of IOL decentration and tilt were measured using SS-OCT. Visual acuity, intraocular pressure, spherical equivalent, axial length, contrast sensitivity, and satisfaction questionnaire were evaluated before and one-month post-surgery. Additionally, postoperative internal cylinder measurements were obtained using a wavefront aberrometer. Correlation factors between each parameter and IOL decentration or tilt were analyzed. Results: This study included 100 eyes from 100 patients. Mean IOL decentration and tilt were 0.21 ± 0.13 mm and 5.01 ± 1.49°, respectively. Conventional cataract surgery (versus FLACS, P = 0.001) and male sex (versus female, P = 0.047) were significantly correlated with higher postoperative decentration. Preoperative lens diameter (P < 0.001), preoperative lens tilt (P = 0.007), and preoperative intraocular pressure (P = 0.027) were correlated with higher postoperative tilt. Fifty eyes that underwent FLACS demonstrated mean postoperative decentration of 0.21 ± 0.13 mm and tilt of 4.64 ± 1.48°. Compared with the conventional surgery group, the FLACS group significantly differed in postoperative decentration (0.30 ± 0.12 mm, P < 0.001) but not in tilt (5.03 ± 1.35°, P = 0.173). Postoperative visual acuity did not significantly differ between the two groups. Conclusion: Patients who underwent FLACS demonstrated better IOL decentration and tilt than those who underwent conventional cataract surgery one-month post-surgery. However, differences in IOL decentration and tilt did not affect postoperative visual acuity.

13.
Front Med (Lausanne) ; 11: 1386979, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38737759

RESUMEN

Primary vitreoretinal lymphoma (PVRL) is often associated with central nervous system involvement, contributing to a heightened mortality rate, thus imaging features that are characteristic enough to be potential biomarkers of PVRL are important, either in diagnosis or in assessment of disease activity. This report details the case of a 68-year-old male who presented with blurred vision in both eyes persisting for 2 months. Fundus examination demonstrated vitreous opacity and multiple subretinal yellow nodular lesions of varying sizes in the peripheral fundus of both eyes. Multiple vertical hyperreflective lesions in the neural retina of posterior pole, indistinct outer retina borders in the fovea, and hyperreflective lesions in the sub-retinal pigment epithelium (RPE) space of the peripheral retina were demonstrated on swept-source optical coherence tomography (SS-OCT) of the left eye. Hyperflow signals corresponding to the vertical hyperreflective lesions were detected on swept-source optical coherence tomography angiography (SS-OCTA) images of retinal deep capillary plexus (DCP) layer. Notably, the hyperflow signals, precisely located around retinal vessels from the nerve fiber layer to the outer plexiform layer, were postulated to stem from the dilation of infiltrated retinal vessels. Vitreous pathological results of the left eye confirmed the diagnosis of PVRL. Treatments with intravitreal methotrexate injections led to a marked improvement of best-corrected visual acuity (BCVA) and regression of the hyperflow microinfiltration lesions demonstrated on SS-OCTA. In conclusion, SS-OCTA effectively delineated the vertical hyperreflective lesions and corresponding hyperflow signals in the posterior pole macular region of a patient with PVRL. These lesions significantly diminished following intravitreal methotrexate injections. We speculated that the specific hyperflow signals on SS-OCTA could act as a potential biomarker of PVRL, and SS-OCTA holds promise in facilitating early diagnosis and monitoring therapeutic responses in PVRL cases.

14.
Sci Rep ; 14(1): 7984, 2024 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-38575630

RESUMEN

The extent of surgical resection is an important prognostic factor in the treatment of patients with glioblastoma. Optical coherence tomography (OCT) imaging is one of the adjunctive methods available to achieve the maximal surgical resection. In this study, the tumor margins were visualized with the OCT image obtained from a murine glioma model. A commercialized human glioblastoma cell line (U-87) was employed to develop the orthotopic murine glioma model. A swept-source OCT (SS-OCT) system of 1300 nm was used for three-dimensional imaging. Based on the OCT intensity signal, which was obtained via accumulation of each A-scan data, an en-face optical attenuation coefficient (OAC) map was drawn. Due to the limited working distance of the focused beam, OAC values decrease with depth, and using the OAC difference in the superficial area was chosen to outline the tumor boundary, presenting a challenge in analyzing the tumor margin along the depth direction. To overcome this and enable three-dimensional tumor margin detection, we converted the en-face OAC map into an en-face difference map with x- and y-directions and computed the normalized absolute difference (NAD) at each depth to construct a volumetric NAD map, which was compared with the corresponding H&E-stained image. The proposed method successfully revealed the tumor margin along the peripheral boundaries as well as the margin depth. We believe this method can serve as a useful adjunct in glioma surgery, with further studies necessary for real-world practical applications.


Asunto(s)
Glioblastoma , Glioma , Humanos , Animales , Ratones , Glioblastoma/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , NAD , Glioma/patología , Imagenología Tridimensional
15.
Int J Ophthalmol ; 17(4): 707-712, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38638269

RESUMEN

AIM: To evaluate the relationship of overweight and obesity with retinal and choroidal thickness in adults without ocular symptoms by swept-source optical coherence tomography (SS-OCT). METHODS: According to the body mass index (BMI) results, the adults enrolled in the cross-sectional study were divided into the normal group (18.50≤BMI<25.00 kg/m2), the overweight group (25.00≤BMI<30.00 kg/m2), and the obesity group (BMI≥30.00 kg/m2). The one-way ANOVA and the Chi-square test were used for comparisons. Pearson's correlation analysis was used to evaluate the relationships between the measured variables. RESULTS: This research covered the left eyes of 3 groups of 434 age- and sex-matched subjects each: normal, overweight, and obesity. The mean BMI was 22.20±1.67, 26.82±1.38, and 32.21±2.35 kg/m2 in normal, overweight and obesity groups, respectively. The choroid was significantly thinner in both the overweight and obesity groups compared to the normal group (P<0.05 for all), while the retinal thickness of the three groups did not differ significantly. Pearson's correlation analysis showed that BMI was significantly negatively correlated with choroidal thickness, but no significant correlation was observed between BMI and retinal thickness. CONCLUSION: Choroidal thickness is decreased in people with overweight or obesity. Research on changes in choroidal thickness contributes to the understanding of the mechanisms of certain ocular disorders in overweight and obese adults.

16.
BMC Ophthalmol ; 24(1): 176, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38632531

RESUMEN

OBJECTIVE: In this study, we used ultra-wide field swept-source optical coherence tomography angiography (UWF SS-OCTA) to assess changes in retinal thickness (RT) and choroidal parameters in individuals who had received a diagnosis of central serous chorioretinopathy (CSC). METHODS: The study encompassed the evaluation of 59 eyes from 47 patients with a diagnosis of CSC, alongside 33 fellow eyes and 31 eyes from healthy individuals (controls). The parameters assessed included RT, choroidal thickness (CT), choriocapillaris density, vascular density of the large choroidal vessel layer, three-dimensional choroidal vascularity index (3D-CVI), choroidal vessel volume per unit area (mCVV/a), and choroidal stroma volume per unit area (mCSV/a). RESULTS: Metrics including mCVV/a, mCSV/a, 3D-CVI, CT, and RT exhibited significantly elevated values in the eyes affected by CSC compared to those of the control group across nine subfields. Moreover, a substantial number of the subfields in both CSC-affected and fellow eyes exhibited increased values for mCVV/a, mCSV/a, 3D-CVI, CT, and RT when compared with the control group. Additionally, acute and chronic CSC subfields demonstrated significantly elevated values for mCVV/a, mCSV/a, 3D-CVI, CT, and RT in comparison to healthy control eyes. Notably, specific subfields associated with complex and atypical forms of CSC revealed higher metrics compared to those of the control group. CONCLUSION: In conclusion, the UWF SS-OCTA proved to be a valuable tool for exploring the anatomical etiology and clinical classification and diagnosis of CSC.


Asunto(s)
Coriorretinopatía Serosa Central , Humanos , Coriorretinopatía Serosa Central/diagnóstico , Estudios Transversales , Angiografía con Fluoresceína/métodos , Tomografía de Coherencia Óptica/métodos , Agudeza Visual , Coroides/irrigación sanguínea , Estudios Retrospectivos
17.
Clin Ophthalmol ; 18: 1117-1124, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38686014

RESUMEN

Purpose: To evaluate postoperative outcomes after implantation of toric intraocular lenses (IOLs) made of high-water-content hydrophobic acrylic material in Japanese patients using a swept-source optical coherence tomography (SS-OCT) biometer integrated with a surgical guiding system. Patients and Methods: In this prospective observational study, toric IOL models CNW0T3 to CNW0T9 (Alcon) were implanted in 33 eyes of 33 patients and followed-up for one month. Powers and toric models were determined using an SS-OCT biometer ARGOS® Ver 1.5 (Alcon), and the IOLs were aligned using surgical guidance. Differences between planned and actual axis positions at the end of the surgery (misalignment) and rotations from the end of surgery to one month postoperatively were measured. Additionally, postoperative uncorrected visual acuity, refraction, and residual astigmatism were evaluated. Results: Mean and median misalignments were 2.3° (standard deviation [SD]: 1.6, 95% confidence interval [CI]: 1.7-2.9) and 2°, and those of postoperative rotation were 2.4° (SD: 2.6, 95% CI: 1.5-3.4) and 2°, respectively. Mean postoperative refraction was 0.06 D (SD: 0.62). Prediction errors within ±0.5 and ±1.0 D were 69.7% and 93.9%, respectively. Mean residual astigmatisms were 0.19 D (SD: 0.41), and mean uncorrected visual acuity was 0.00 logMAR (SD: 0.11), and 64% of the eyes scored 20/20 or better. Conclusion: Implantation of high-water-content hydrophobic acrylic toric IOLs using SS-OCT biometry integrated with a surgical guiding system effectively corrected corneal astigmatism with accurate IOL alignment in Japanese patients.

18.
Diagnostics (Basel) ; 14(5)2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38473032

RESUMEN

The VEMoS-AXL system is a new optical biometer based on spectral domain optical coherence tomography (SD-OCT) that has been tested in terms of intrasession repeatability and compared with a swept-source optical coherence tomography biometer (SS-OCT), which is recognized as the gold standard for the performance of an agreement analysis. A biometric analysis was performed three consecutive times in 120 healthy eyes of 120 patients aged between 18 and 40 years with the SD-OCT system, and afterwards, a single measurement was obtained with the SS-OCT system. Within-subject standard deviations were 0.004 mm, 4.394 µm, and 0.017 mm for axial length (AL), central corneal thickness (CCT), and anterior chamber depth (ACD) measures obtained with the SD-OCT biometer, respectively. The agreement between devices was good for AL (limits of agreement, LoA: -0.04 to 0.03 mm) and CCT (LoA: -4.36 to 14.38 µm), whereas differences between devices were clinically relevant for ACD (LoA: 0.03 to 0.21 mm). In conclusion, the VEMoS-AXL system provides consistent measures of anatomical parameters, being most of them interchangeable with those provided by the SS-OCT-based gold standard.

19.
Eye Vis (Lond) ; 11(1): 9, 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38433240

RESUMEN

BACKGROUND: To evaluate the intraobserver repeatability and interobserver reproducibility of a newly developed dynamic real-time visualization 25 kHz swept-source optical coherence tomography (SS-OCT) based biometer (ZW-30, TowardPi Medical Technology Ltd, China) and compare its agreement with another SS-OCT based biometer (IOLMaster 700, Carl Zeiss Meditec AG, Jena, Germany). METHODS: Eighty-two healthy right eyes were enrolled in this prospective observational study. Measurements were repeated for three times using the ZW-30 and IOLMaster 700 in a random order. Obtained parameters included axial length (AL), central corneal thickness (CCT), aqueous depth (AQD), anterior chamber depth (ACD), lens thickness (LT), mean keratometry (Km), astigmatism magnitude (AST), vector J0, vector J45, and corneal diameter (CD). The within-subject standard deviation (Sw), test-retest (TRT) variability, coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were adopted to assess the intraobserver repeatability and interobserver reproducibility. The double-angle plot was also used to display the distribution of AST. To estimate agreement, Bland-Altman plots were used. RESULTS: For the intraobserver repeatability and interobserver reproducibility, the Sw, TRT and CoV for all parameters were low. Meanwhile, the ICC values were all close to 1.000, except for the J45 (ICC = 0.887 for the intraobserver repeatability). The double-angle plot showed that the distribution of AST measured by these two devices was similar. For agreement, the Bland-Altman plots showed narrow 95% limits of agreements (LoAs) for AL, CCT, AQD, ACD, LT, Km AST, J0, J45, and CD (- 0.02 mm to 0.02 mm, - 7.49 µm to 8.08 µm, - 0.07 mm to 0.04 mm, - 0.07 mm to 0.04 mm, - 0.07 mm to 0.08 mm, - 0.16 D to 0.30 D, - 0.30 D to 0.29 D, - 0.16 D to 0.16 D, - 0.23 D to 0.13 D, and - 0.39 mm to 0.10 mm, respectively). CONCLUSIONS: The newly dynamic real-time visualization biometer exhibited excellent intraobserver repeatability and interobserver reproducibility. The two devices both based on the SS-OCT principle had similar ocular parameters measurement values and can be interchanged in clinical practice.

20.
Front Endocrinol (Lausanne) ; 15: 1292255, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38481443

RESUMEN

Introduction: The study aimed to evaluate the effect of mydriasis on macular and peripapillary metrics with swept-source optical coherence tomography angiography (SS-OCTA) in healthy subjects. Methods: Thirty-five healthy subjects were included. The macular region was scanned by the 3×3mm mode and 6×6mm mode, and the peripapillary region was scanned by the 4.5×4.5mm mode on both eyes with SS-OCTA before and after mydriasis. Macular and peripapillary metrics, including retinal vessel density (VD) and fundus thickness were measured by the built-in program. Data of the right eye were analyzed. Results: The signal strength of the scans was comparable before and after mydriasis (all P>0.05). There were no significant differences in foveal avascular zone (FAZ) parameters and retinal VD of most sectors in both macular and peripapillary areas (all P>0.05). Choroidal thickness was decreased, outer and whole retinal thickness was increased in most of the macular sectors after mydriasis (all P<0.05). Choroidal thickness was decreased in all the peripapillary sectors, but whole retinal thickness and GCC thickness were increased in some peripapillary sectors after mydriasis (all P<0.05). Conclusions: FAZ parameters and retinal VD in the most macular and peripapillary regions are not affected by mydriasis. The thickness of the choroid is decreased after mydriasis, while the thickness of retinal layers in some sectors may be increased after mydriasis.


Asunto(s)
Mácula Lútea , Midriasis , Humanos , Angiografía con Fluoresceína/métodos , Tomografía de Coherencia Óptica/métodos , Vasos Retinianos/diagnóstico por imagen , Mácula Lútea/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA