Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
J Clin Med ; 13(16)2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39201092

RESUMEN

Objectives: Tibial eminence fractures account for 2% to 5% of all knee injuries. Low-grade fractures, such as Type I, are typically treated conservatively, whereas high-grade fractures, such as Types III and IV, usually require surgical intervention. This paper describes a modified surgical arthroscopic technique, which employs pull-through triangle suture fixation for Type II and Type III arthroscopic intercondylar eminence avulsion fractures. In addition, we examined the efficacy and complication rate compared to the existing literature. Methods: Data were prospectively collected for knee arthroscopy surgeries and retrospectively analyzed with a minimum two-year follow-up. Twenty-three consecutive adults underwent arthroscopic treatment of displaced intercondylar Type II and Type III eminence fractures, as evidenced by clinical examination and imaging studies between May/2008 and May/2021. The patient's knee evaluation was performed using clinical symptoms and physical examination, along with International Knee Documentation Committee (IKDC) questionnaire and Tegner Activity Score. Compared to the literature, post-hoc power was calculated based on the mean Tegner Activity Score in our analysis. Results: fifteen females and eight males (mean age 33.9 years, range 19-56 years) were enrolled. The average postoperative follow-up was 35.4 months (27-53). The post-hoc power was 95% confidence in terms of the Tegner Activity Score. The mean ± standard deviation postoperative Tegner Activity Score was 8.2 ± 1.7 (6.8-10.0). Fifteen patients were classified as IKDC A (normal), six as IKDC B (nearly normal), and two as IKDC C (abnormal). The mean IKDC subjective score was 72.7 ± 23 (23-100). Twenty-four patients achieved normal flexion degrees compared with the unaffected side, while one patient achieved a flexion of only 0-90°. The group's mean flexion range of motion was 123 ± 16° (90-150°). Conclusion: This study presents a modified surgical arthroscopic suture fixation technique for tibial eminence fractures. The procedure is relatively simple and requires no more than basic arthroscopy equipment. The clinical and radiographic results indicate that this technique is safe, efficient, enables early initiation of rehabilitation, and has a lower complication rate in a variety of aspects compared with other fixation techniques used for tibial eminence fractures.

2.
J Oral Implantol ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38967002

RESUMEN

PURPOSE: This study aims to evaluate the clinical outcomes of using demineralized freeze-dried allogeneic bone blocks (DFDABB) combined with the periosteal vertical mattress suture (PVMS) technique for the reconstruction of severe horizontal alveolar bone deficiencies in the maxilla. METHOD: In continuous horizontal maxillary defects cases, bone augmentation was performed using DFDABB and deproteinized bovine bone matrix (DBBM) filling the interstice. Subsequently, a resorbable collagen membrane was carefully placed over the graft surface, and both the membrane and bone graft were firmly secured using the periosteal vertical mattress suture technique (PVMS). Linear changes were assessed through superimposed cone-beam computed tomography (CBCT) scans obtained before the operation and after a healing period of 6-10 months. RESULTS: A total of 7 female patients with ten bone blocks and 13 implants were included in this study. One of the wounds was slightly ruptured postoperatively without infection, and all implants showed successful osseointegration. The average alveolar ridge width at a point 5 mm below the crest was 4.52 ± 2.03 mm before bone graft and 9.79 ± 1.57 mm after implantation, with an average increase of 5.26 ± 1.97 mm. Similarly, at a point 10 mm below the crest, the pre-graft alveolar ridge width measured 7.23 ± 3.60 mm, and post-implantation, it expanded to 11.81 ± 2.90 mm, showing an average gain of 4.58 ± 2.01 mm. CONCLUSION: This case series demonstrates the successful application of DFDABB combined with the PVMS technique to achieve adequate bone width for implantation at severe continuous horizontal bone deficiency of the maxilla. DFDABB with the PVMS technique resulted in superior horizontal bone gain during maxillary bone augmentation with horizontal continuity deficiency. However, further studies are necessary to validate these findings.

3.
J Orthop Surg Res ; 19(1): 445, 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39075599

RESUMEN

PURPOSE: To assess the clinical efficacy of arthroscopic treatment for posterior cruciate ligament (PCL) tibial avulsion fractures using high-intensity suture binding combined with button plate suspension fixation. METHODS: We retrospectively analyzed clinical data from 32 patients with PCL tibial avulsion fractures treated at our hospital from July 2020 to August 2023. We recorded operation time, intraoperative and postoperative complications, and used imaging to assess fracture reduction and healing. Pain and knee function were evaluated using the Visual Analogue Scale (VAS), range of knee motion, Lysholm score, and International Knee Documentation Committee (IKDC) score. STUDY DESIGN: Case series; Level of evidence, 4. RESULTS: All patients were followed for 6 to 18 months, averaging 13.6 months. All incisions healed successfully without postoperative complications. X-rays taken on the first postoperative day showed satisfactory fracture reduction. Three-month post-surgery imaging confirmed healed fractures and no internal fixation failures. At the final follow-up, knee function was well recovered, with only one patient exhibiting a positive posterior drawer test of degree I. Furthermore, the mean VAS score was 0. 5 (range 0.0 to 1.0), active knee extension was 2. 2° (range 0.0 to 5.0), and active knee flexion was 137.7° (range 130.0 to 145.0). The mean Lysholm score was 91.5(range 89.3 to 94.0), and the IKDC score averaged 83.8 ± 3.7, and these outcomes showed statistically significant improvement from preoperative levels (P < 0.001). CONCLUSIONS: Arthroscopic high-intensity suture binding combined with button plate suspension fixation for PCL tibial avulsion fractures offers several benefits: it is minimally invasive, results in less postoperative pain, enables earlier functional exercise, and provides satisfactory clinical outcomes with fewer complications.


Asunto(s)
Artroscopía , Placas Óseas , Fijación Interna de Fracturas , Fracturas por Avulsión , Ligamento Cruzado Posterior , Fracturas de la Tibia , Humanos , Masculino , Adulto , Femenino , Artroscopía/métodos , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/diagnóstico por imagen , Estudios Retrospectivos , Ligamento Cruzado Posterior/cirugía , Ligamento Cruzado Posterior/lesiones , Persona de Mediana Edad , Resultado del Tratamiento , Fijación Interna de Fracturas/métodos , Fracturas por Avulsión/cirugía , Fracturas por Avulsión/diagnóstico por imagen , Adulto Joven , Técnicas de Sutura , Estudios de Seguimiento , Rango del Movimiento Articular
4.
World J Orthop ; 15(7): 642-649, 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39070933

RESUMEN

BACKGROUND: Tibial avulsion fractures of the posterior cruciate ligament (PCL) are challenging to treat and compromise knee stability and function. Traditional open surgery often requires extensive soft tissue dissection, which may increase the risk of morbidity. In response to these concerns, arthroscopic techniques have been evolving. The aim of this study was to introduce a modified arthroscopic technique utilizing an M-shaped suture fixation method for the treatment of tibial avulsion fractures of the PCL and to evaluate its outcomes through a case series. AIM: To evaluate the effects of arthroscopic M-shaped suture fixation on treating tibia avulsion fractures of the PCL. METHODS: We developed a modified arthroscopic M-shaped suture fixation technique for tibia avulsion fractures of the PCL. This case series included 18 patients who underwent the procedure between January 2021 and December 2022. The patients were assessed for range of motion (ROM), Lysholm score and International knee documentation committee (IKDC) score. Postoperative complications were also recorded. RESULTS: The patients were followed for a mean of 13.83 ± 2.33 months. All patients showed radiographic union. At the final follow-up, all patients had full ROM and a negative posterior drawer test. The mean Lysholm score significantly improved from 45.28 ± 8.92 preoperatively to 91.83 ± 4.18 at the final follow-up (P < 0.001), and the mean IKDC score improved from 41.98 ± 6.06 preoperatively to 90.89 ± 5.32 at the final follow-up (P < 0.001). CONCLUSION: The modified arthroscopic M-shaped suture fixation technique is a reliable and effective treatment for tibia avulsion fractures of the PCL, with excellent fracture healing and functional recovery.

5.
Arch Orthop Trauma Surg ; 144(7): 3153-3159, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38896276

RESUMEN

PURPOSE: The ideal surgical management for tibial eminence avulsion fractures remains controversial with varying approach, methods of fixation and post-operative regimes reported throughout literature. The current systematic review and meta-analysis aims to compare between the different approaches, methods of fixation and post-operative regimes for tibial eminence fractures. METHODS: The systematic review was conducted according to PRISMA guidelines. A search was conducted using PubMed, MEDLINE and CINAHL databases. The keywords used were "anterior cruciate ligament", "tibial spine" or "tibial eminence" and "fracture" or "avulsion". All original human studies that reported the surgical outcomes of tibial eminence fractures were included. Individual patient data meta-analysis was performed. RESULTS: 48 studies with 1367 patients were included. Arthroscopic fixation resulted in significantly greater stability in terms of anterior drawer test (p = 0.018) and Lachman's test (p = 0.042), as compared to open fixation, though there was no significant difference for pivot shift test. There was no significant difference identified in functional scores and activity, including Lysholm score, IKDC subjective score, Tegner score and return to sports. Suture fixation had significantly increased stability compared to screw fixation, in terms of anterior drawer test (p = 0.001) and Lachman's test (p = 0.001), though no significant difference was identified for pivot shift test. Significantly better subjective scores and return to activity were also noted for suture fixation, in terms of Lysholm score (p = 0.008), IKDC subjective score (p = 0.001) and Tegner score (p = 0.001), though no significant difference was identified for return to sports. CONCLUSION: Arthroscopic and suture fixation had significantly superior outcomes when compared to open and screw fixation. Arthroscopic fixation resulted in significantly improved stability of the knee as compared to open fixation, though no significant difference was identified in terms of functional knee scores and return to activity. Suture fixation resulted in significantly improved stability of the knee and functional knee screws as compared to screw fixation.


Asunto(s)
Artroscopía , Fracturas por Avulsión , Fracturas de la Tibia , Humanos , Fracturas de la Tibia/cirugía , Fracturas por Avulsión/cirugía , Artroscopía/métodos , Fijación Interna de Fracturas/métodos , Técnicas de Sutura , Tornillos Óseos
6.
J Pediatr Surg ; 59(9): 1703-1707, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38522977

RESUMEN

PURPOSE: Costal cartilage resection with or without rib resection is the gold standard surgery for slipping rib syndrome. Minimally invasive restoration of normal anatomy via nonabsorbable sutures has been described in the adult population with encouraging results. We sought to assess the efficacy of minimally invasive sutured fixation of the hypermobile rib in the pediatric population. METHODS: A retrospective review was performed at Mayo Clinic involving 31 pediatric patients diagnosed with slipped rib syndrome. Minimally invasive sutured open reduction internal fixation was performed between 2020 and 2022. The standardized Örebro Musculoskeletal Pain Screening Questionnaire was given at dedicated time points pre- and post-operatively to assess efficacy. Significance was determined via the Wilcoxon rank sum test. RESULTS: SRS was diagnosed clinically in 31 patients (24 females, 7 males, 1220 years-old). Symptoms were present for an average of 18.9 months and patients had seen an average of 4.7 specialists. Traumatic causes were identified in three patients and eight patients had hypermobility. At one month follow up, there were no surgical complications and patients reported significantly less pain (p < 0.001). Preoperative analgesics reduced by 80%. Ultimately, seven patients underwent a second operation; three patients underwent a third operation; one patient underwent five total operations. Recurrent pain was reported in six patients. Only nine patients followed-up at 1-year post-operation. CONCLUSION: Pediatric patients with SRS demonstrated an early positive response to suture fixation without costal cartilage excision. Reoperation and recurrent pain, however, remain significant in this population. LEVEL OF EVIDENCE: Level IV. TYPE OF STUDY: Case series with no comparison group.


Asunto(s)
Procedimientos Quirúrgicos Mínimamente Invasivos , Costillas , Técnicas de Sutura , Humanos , Femenino , Masculino , Estudios Retrospectivos , Niño , Adolescente , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Costillas/cirugía , Resultado del Tratamiento , Preescolar , Estudios de Seguimiento
7.
J ISAKOS ; 9(3): 415-417, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38518894

RESUMEN

A tibial spine fracture refers to an intraarticular fracture of the osseous insertion of the anterior cruciate ligament at the proximal tibia, commonly seen in pediatric and adolescent patients. This fracture is classified based on the degree of displacement and the presence or absence of an intact posterior hinge point. For significantly displaced fractures, surgical reduction and fixation are often recommended. Both open and arthroscopic approaches have been described. This technical note describes our technique for arthroscopic-assisted reduction and fixation of tibial spine fractures using trans-osseous tunnels and suture fixation over a bone bridge. This technique restores native anatomy, provides fracture compression, and has favorable biomechanical properties, allowing for early range of motion.


Asunto(s)
Artroscopía , Fijación Interna de Fracturas , Técnicas de Sutura , Fracturas de la Tibia , Humanos , Artroscopía/métodos , Fracturas de la Tibia/cirugía , Fijación Interna de Fracturas/métodos , Adolescente , Rango del Movimiento Articular , Ligamento Cruzado Anterior/cirugía , Fenómenos Biomecánicos , Resultado del Tratamiento , Masculino , Suturas , Tibia/cirugía , Fracturas de Rodilla
8.
J Minim Invasive Gynecol ; 31(1): 57-63, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37838016

RESUMEN

STUDY OBJECTIVE: To evaluate the feasibility and effectiveness of hysteroscopic suture fixation of the levonorgestrel-releasing intrauterine system (LNG-IUS) for the treatment of adenomyosis. DESIGN: A retrospective case series. SETTING: Two teaching hospitals with the technology of hysteroscopic suture fixation of the LNG-IUS. PATIENTS: The study reviewed 79 adenomyosis patients who received the hysteroscopic suture fixation of the LNG-IUS from January 2021 to May 2022. INTERVENTION: Hysteroscopic suture fixation of the LNG-IUS to the posterior uterine wall with nondissolvable suture. MEASUREMENTS AND MAIN RESULTS: All patients underwent one-year postoperative follow-up to evaluate the LNG-IUS expulsion rate, postoperative efficacy, and side effects. Two patients (2.6%) experienced expulsion of the LNG-IUS at 8 months and 12 months postoperatively, respectively. The visual analog pain scale, pictorial blood loss assessment chart score and carbohydrate antigen 125 markedly decreased after the suture fixation of the LNG-IUS compared with baseline in all patients (p <.001). Hemoglobin increased significantly (p <.001). The most common side effect was irregular bleeding, which accounted for 44.3%. The second common side effect was weight gain, which accounted for 29.2%. The composite effectiveness based on pain and bleeding showed that the effective treatment rates at 1, 3, 6, and 12 months after surgery were 92.4%, 97.4%, 96.2%, and 97.4% respectively. CONCLUSIONS: Hysteroscopic suture fixation of the LNG-IUS to the uterine fundus was associated with low expulsion rates and significantly improved dysmenorrhea and bleeding.


Asunto(s)
Adenomiosis , Dispositivos Intrauterinos Medicados , Femenino , Humanos , Adenomiosis/tratamiento farmacológico , Adenomiosis/cirugía , Adenomiosis/complicaciones , Levonorgestrel/uso terapéutico , Estudios Retrospectivos , Estudios de Factibilidad , Dispositivos Intrauterinos Medicados/efectos adversos , Suturas
9.
Trauma Case Rep ; 48: 100963, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37928717

RESUMEN

Displaced comminuted patellar fractures necessitate surgical treatment to restore the function of the extensor mechanism of the knee. One of the main challenges in the fixation of comminuted fracture of the patella is achieving an anatomic articular reduction with a stable fixation to allow early mobilization and prevent knee stiffness. Various common surgical fixation methods necessitate the use of metallic implants. Due to its superficial location, hardware-related complications and re-operations are common after patellar fixation. We present a case of a comminuted patellar fracture fixed using a modified cerclage and suture mesh fixation technique using high-strength braided nonabsorbable sutures. This provided a rigid fixation that allowed early range of motion while avoiding the risk of having symptomatic hardware.

10.
Shoulder Elbow ; 15(4): 424-435, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37538526

RESUMEN

Introduction: Tension Band Wiring (TBW) has traditionally been the cornerstone of operative management for simple displaced olecranon fractures but its success is limited by high complication rates, mainly related to metalwork irritation and fixation failure. Over the last twelve years, a number of novel fixation methods not involving metalwork have been described in case series (suture fixation, SF and suture-anchor fixation, SAF) with promising early results. In this systematic review, the outcomes of SF and SAF techniques are presented alongside those for TBW for the treatment of closed olecranon fractures without elbow instability. Materials and methods: Five databases (Medline, Scholar, Scopus, Prospero and Cochrane) were searched for clinical studies involving TBW/SF/SAF for closed Mayo 1A/1B/2A/2B olecranon fractures from January 2010 onwards. Primary outcomes included overall complication and reoperation rates, as well as the rate of each specific complication. Elbow range of movement, surgeon and patient-reported outcome measures were defined as secondary outcomes. Results: Eighteen studies were included, nine of which involved SF/SAF (99 patients) and nine TBW (382 patients). SF/SAF techniques were associated with lower rates of fracture/implant displacement (2% versus 9.7%, p = 0.01), implant irritation (1% versus 30.1%, p < 0.001) and overall complications (8% versus 46.1%, p < 0.001) when compared to TBW. Reoperation rates were lower for SF/SAF (3% versus 37.2%, p < 0.001). Total flexion/extension arc achieved was similar (130.16 ± 2.11 versus 129.45 ± 0.93 degrees). On average, patients regained a functional arc of flexion (135.21 ± 4.81 TBW versus 131.32 ± 12.99 SF/SAF) and extension (1.16 ± 7.54 SF/SAF versus 5.76 ± 7.98 TBW). Conclusion: Current evidence suggests that SF/SAF of simple olecranon fractures is a safe and effective alternative to the current gold standard TBW fixation, with preliminary evidence suggestive of lower complication and reoperation rates. Firm conclusions of equivalence or superiority are not possible based on the current poor quality of literature available. Until the outcomes of high-quality prospective studies are available, patients should be carefully counselled that suture methods remain novel and outcomes should be regularly audited.

11.
World Neurosurg ; 175: e1210-e1219, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37427700

RESUMEN

BACKGROUND: Electrodes for stereotactic electroencephalography (SEEG) are typically fixed to the skull with anchor bolts. When anchor bolts are unavailable, electrodes have to be fixed using other methods, carrying the possibility of electrode shift. This study, therefore, evaluated the characteristics of electrode tip shift during SEEG monitoring in patients with electrodes fixed using the suture technique. METHODS: We retrospectively included patients who underwent SEEG implantation with suture fixation and evaluated the tip shift distance (TSD) of electrodes. Possible influences evaluated included: 1) implantation period, 2) lobe of entry, 3) unilateral or bilateral implantation, 4) electrode length, 5) skull thickness, and 6) scalp thickness difference. RESULTS: A total of 50 electrodes in 7 patients were evaluated. TSD was 1.4 ± 2.0 mm (mean ± standard deviation). Implantation period was 8.1 ± 2.2 days. Entry lobe was frontal for 28 electrodes and temporal for 22 electrodes. Implantation was bilateral for 25 electrodes and unilateral for 25 electrodes. Electrode length was 45.4 ± 14.3 mm. Skull thickness was 6.0 ± 3.7 mm. Scalp thickness difference was -1.5 ± 2.1 mm, which was found greater in temporal lobe entry compared with frontal lobe entry. According to univariate analyses, neither implantation period nor electrode length correlated with TSD. Multivariate regression analysis showed that only greater scalp thickness difference correlated significantly with greater TSD (P = 0.0018). CONCLUSIONS: Greater scalp thickness difference correlated with greater TSD. Surgeons need to consider the degree of scalp thickness difference and electrode shift when using suture fixation, especially with temporal lobe entry.


Asunto(s)
Electroencefalografía , Técnicas Estereotáxicas , Humanos , Estudios Retrospectivos , Electrodos Implantados , Electroencefalografía/métodos , Suturas
12.
Injury ; 54(8): 110919, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37441859

RESUMEN

PURPOSE: Traditional tension band wire fixation (TBWF) of olecranon fractures is associated with high revision rates due to implant-related complications. The purpose of the study was to compare the strength of fixation in olecranon fractures between TBWF and an all-suture based technique. METHODS: A transverse fracture was created in 20 paired fresh-frozen human cadaveric elbows. Fractures were randomly (alternating right-left) assigned for fixation with either tension band suture fixation (TBSF) or TBWF. The elbow was fixed in 90° of flexion and underwent cycling loading by pulling the triceps tendon to 300 N for 200 cycles. Fracture displacement was optically recorded using digital image correlation (DIC). Finally, load-to-failure was assessed by a monotonic pull to 1000 N and failure mechanism was recorded. RESULTS: Two specimens in the TBSF group were excluded from the cycling loading analysis due to technical difficulties with the DIC. After cyclic loading, median (min-max) fracture displacement was 0.28 mm (0.10-0.44) in the TBSF group and 0.18 mm (0.00-1.48) in the TBWF group (p = 0.315). No difference was found between the two groups in the repeated measures analysis of variance (p = 0.329). In the load-to-failure test, 6/10 specimens failed in the TBSF group (median load-to-failure 791 N) vs. 8/10 in the TBWF group (median load-to-failure 747 N). The TBSF constructs failed due to fracture of the dorsal cortex, suture breakage or triceps failure. The TBWF constructs failed due to breakage of the wire. CONCLUSION: There was no difference in fixation strength between the TBWF and TBSF constructs. Our findings suggest TBSF to be a feasible alternative to TBWF and we hypothesize that a non-metallic implant may have fewer implant-related complications. LEVEL OF EVIDENCE: Basic science study.


Asunto(s)
Fracturas Óseas , Fractura de Olécranon , Olécranon , Fracturas del Cúbito , Humanos , Fenómenos Biomecánicos , Fracturas del Cúbito/cirugía , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Olécranon/cirugía , Hilos Ortopédicos , Complicaciones Posoperatorias , Suturas , Cadáver
14.
BMC Surg ; 23(1): 73, 2023 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-36991429

RESUMEN

OBJECTIVE: This study aimed to explore the feasibility and advantages of a modified chest tube suture-fixation technique in uniportal video-assisted thoracic surgery for pulmonary resection. METHODS: A retrospective analysis was conducted on 116 patients who underwent uniportal video-assisted thoracic surgery (U-VATS) for lung diseases in Zhengzhou People's Hospital between October 2019 and October 2021. Patients were stratified into two groups based on the applied suture-fixation methods, i.e., 72 patients in the active group and 44 patients in the control group. The two groups were subsequently compared in the terms of gender, age, operation method, indwelling time of chest tube, postoperative pain score, chest tube removal time, wound healing grade, length of hospital stay, incision healing grade, and patient satisfaction. RESULTS: There was no significant difference between the two groups in terms of gender, age, operation method, indwelling time of chest tube, postoperative pain score, and length of hospital stay (P = 0.167, 0.185, 0.085, 0.051, 0.927, and 0.362, respectively). However, the chest tube removal time, incision healing grade, and incision scar satisfaction in the active group were significantly better compared with those of the control group (P = < 0.001, 0.033, and < 0.001, respectively). CONCLUSION: In summary, the new suture-fixation approach can minimize the number of stitches, and time necessary for chest tube removal process, and avoid the pain experienced when removing the drainage tube. This method is more feasible, has better incision conditions, and provides a convenient tube removal, making it more suitable to patients.


Asunto(s)
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/cirugía , Tubos Torácicos , Estudios Retrospectivos , Dolor Postoperatorio/cirugía , Neumonectomía/métodos , Cirugía Torácica Asistida por Video/métodos , Suturas
15.
J Hand Surg Glob Online ; 5(2): 231-233, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36974281

RESUMEN

Seymour fractures are common injuries in the pediatric population. High rates of deep infection have been reported due to delayed presentation and subsequent treatment. This report describes the case of a 13-year-old male wrestler who presented 1 month after a finger injury that was later diagnosed as a subacute Seymour fracture with osteomyelitis. The patient underwent irrigation and debridement and fracture reduction stabilized with nonabsorbable suture fixation. After 6 weeks of intravenous antibiotics, the patient was recovering well, with radiographic evidence of fracture healing and clearance of infection. This case highlights the use of a single suture as a treatment option for fixation of unstable Seymour fractures with delayed presentation. The management of acute open distal phalangeal physeal fractures is well described in the literature; however, further investigations are warranted into the optimal management of chronically infected digits with unstable Seymour fractures.

16.
Indian J Ophthalmol ; 71(3): 1005-1010, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36872727

RESUMEN

The objective of the study was to evaluate the curative effect of a modified technique of scleral suture fixation with a four-loop foldable intraocular lens (IOL) for eye with inadequate capsule support. This was a retrospective study of 22 eyes with inadequate capsule support of 20 patients who underwent the scleral suture fixation technique with 9-0 polypropylene suture and foldable four-loop IOL implant. Preoperative and follow-up data were collected for all patients. The mean follow-up was 5.08 ± 0.48 months (range: 3-12 months). The mean pre- and postoperative log of minimum angle of resolution (logMAR) uncorrected distance visual acuity was 1.11 ± 0.32 versus 0.09 ± 0.09 (P < 0.001). The mean pre- and postoperative logMAR best corrected visual acuity was 0.37 ± 0.19 versus 0.08 ± 0.07 (P < 0.001). The intraocular pressure (IOP) increased briefly (range: 21-30 mmHg) in eight eyes on the first day postoperatively and returned to normal within 1 week. No IOP drops were used postoperatively. The IOP was 12-19.3 (13.72 ± 1.28) in this follow-up, which had no significant difference compared to the preoperative IOP (t = 0.34, P = 0.74). At this follow-up, there was no hyperemia, local hyperplasia, obvious scar, suture knots, or segment ends observed under the conjunctiva, as well as no pupil deformation or vitreous hemorrhage. The mean postoperative IOL decentration degree was 0.22 ± 0.08 mm. At the 7-day follow-up postoperatively, one side of the IOL was dislocated to the vitreous cavity in one case, which was resolved by reimplantation of a new IOL in time with the same technique. Scleral suture fixation technique of a four-loop foldable IOL was a feasible operation method for an eye with inadequate capsular support.


Asunto(s)
Ojo Artificial , Lentes Intraoculares , Humanos , Estudios Retrospectivos , Esclerótica , Procedimientos Neuroquirúrgicos
17.
Eur J Ophthalmol ; 33(4): 1624-1631, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36691699

RESUMEN

OBJECTIVE: To describe a new strategy to manage ectopia lentis in ASD patients assessing the visual outcomes and safety of supracapsular scleral sutured intraocular lens implantation and analyzing the accuracy of different intraocular lens (IOL) power calculation formulae. METHODS: Eight patients with ASD (13 eyes) were underwent supracapsular scleral suture fixation of posterior chamber (PC) IOL without capsular extirpation. The preoperative and postoperative clinical features were compared. The prediction error values from four formulae (SRK/T, Holladay 1, Hoffer Q, Haigis), with or without Wang-Koch (WK) adjustment, were calculated for the cases. RESULTS: Zonulodialysis and premature cataracts could be the main reason for the decreased vision in patients with ASD. There was a significant improvement in best corrected visual acuity on 3-month follow-up after applying supracapsular scleral suture fixation of PC IOL. The prediction errors of the different formulae showed a slight tendency towards postoperative myopia. The Haigis formula with WK adjustment showed the best performance. CONCLUSIONS: Supracapsular scleral suture fixation of IOLs for retaining the capsule-zonule barrier is a good option for ASD patients. The Haigis formula is recommended for ASD patients treated with supracapsular scleral suture fixation of IOLs. The predicted IOL power should be reduced based on the effect of the new anatomic position of the IOL to achieve a satisfactory visual outcome.


Asunto(s)
Desplazamiento del Cristalino , Lentes Intraoculares , Humanos , Implantación de Lentes Intraoculares , Agudeza Visual , Desplazamiento del Cristalino/cirugía , Esclerótica/cirugía , Estudios Retrospectivos , Refracción Ocular
18.
Bone Jt Open ; 4(1): 27-37, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36641631

RESUMEN

AIMS: Olecranon fractures are usually caused by falling directly on to the olecranon or following a fall on to an outstretched arm. Displaced fractures of the olecranon with a stable ulnohumeral joint are commonly managed by open reduction and internal fixation. The current predominant method of management of simple displaced fractures with ulnohumeral stability (Mayo grade IIA) in the UK and internationally is a low-cost technique using tension band wiring. Suture or suture anchor techniques have been described with the aim of reducing the hardware related complications and reoperation. An all-suture technique has been developed to fix the fracture using strong synthetic sutures alone. The aim of this trial is to investigate the clinical and cost-effectiveness of tension suture repair versus traditional tension band wiring for the surgical fixation of Mayo grade IIA fractures of the olecranon. METHODS: SOFFT is a multicentre, pragmatic, two-arm parallel-group, non-inferiority, randomized controlled trial. Participants will be assigned 1:1 to receive either tension suture fixation or tension band wiring. 280 adult participants will be recruited. The primary outcome will be the Disabilities of the Arm, Shoulder and Hand (DASH) score at four months post-randomization. Secondary outcome measures include DASH (at 12, 18, and 24 months), pain, Net Promotor Score (patient satisfaction), EuroQol five-dimension five-level score (EQ-5D-5L), radiological union, complications, elbow range of motion, and re-operations related to the injury or to remove metalwork. An economic evaluation will assess the cost-effectiveness of treatments. DISCUSSION: There is currently no high-quality evidence comparing the clinical and cost effectiveness of the tension suture repair to the traditional tension band wiring currently offered for the internal fixation of displaced fractures of the olecranon. The Simple Olecranon Fracture Fixation Trial (SOFFT) is a randomized controlled trial with sufficient power and design rigour to provide this evidence for the subtype of Mayo grade IIA fractures.Cite this article: Bone Jt Open 2023;4(1):27-37.

19.
J Orthop ; 35: 7-12, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36325248

RESUMEN

BACKGROUND: Tibial eminence fracture is an intra-articular fracture of bony attachment of ACL. The displaced fragment could hinder the mobility of the knee and may lead joint instabilty; therefore, requires fixation. Arthroscopic suture and screw fixation are the widely used surgical modalities for eminence fractures of the tibia. Past studies have not yet depicted the superiority of one method over the other. Through this cohort study, comparison of the clinical and functional outcomes of these two surgical methods was done. METHODS: A prospective, randomized, interventional study was conducted from December 2019 to January 2022 for comparing the clinical outcome of arthroscopic pull through suture fixation and arthroscopic antegrade cancellous screw fixation in skeletally mature individuals. Ninety patients (45 in each group) were randomly assigned and treated with the above two methods. A comprehensive clinical analysis was done after nine months of surgery for assessment of functional outcome, ligament laxity, range of motion, and complications if any. RESULTS: 65.55% of anterior tibial eminence fractures were caused by road traffic accidents followed by sports injuries (28.88%). The postoperative mean subjective IKDC score in the suture group was 91.36 and for the screw fixation group was 85.71 (p = 0.001). After nine months of surgery, the mean LKS was 91.96 in patients treated with suture fixation and 86.00 in patients treated with screw fixation (p = 0.001). Pivot shift grading was grade 3 in one patient of the suture group and in three patients of the screw group (p = 0.319). Seven patients who had screw fixation required re-surgery for removal of the implant; however, no such complication was seen in the suture fixation group. CONCLUSION: Arthroscopic pull-through suture fixation of tibial avulsion of ACL in skeletally mature patients seems to be a superior intervention over arthroscopic screw fixation with the benefits of better clinical and functional outcomes and decreased chances of re-surgery.

20.
Ophthalmol Ther ; 12(1): 99-110, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36243894

RESUMEN

INTRODUCTION: This study aimed to compare modified knotless transscleral suture fixation of intraocular lens (IOL) with traditional transscleral suture fixation for adolescents and young patients with congenital ectopia lentis (CEL). METHODS: This retrospective cohort study included 49 patients with CEL (60 eyes) who underwent surgery at the Zhongshan Ophthalmic Center. Improvements based on knotless Z-suture fixation technique were made to form a modified knotless method, in which thicker 8-0 polypropylene sutures were used, and double parallel scleral grooves were constructed behind the limbus instead of triangular lamellar scleral flaps to cover suture stitches. Modified knotless transscleral fixation of IOL was conducted on 30 eyes, and the other 30 eyes underwent traditional transscleral fixation surgery. Pre- and postoperative best-corrected visual acuity (BCVA), refractive error, astigmatism, other ocular parameters, and complications were statistically analyzed. RESULTS: For patients in the modified knotless group, the mean cylindrical refractive error and astigmatism at 1 month and 3 months postoperative were lower (all P < 0.05), and the mean IOL tilt degree was smaller at 3 months postoperative (3.21° ± 2.13° vs. 5.65° ± 3.66°, P = 0.032). The incidence of suture exposure in the modified knotless group was also lower than in the controls (0 vs. 16.7%, P = 0.026). No group differences were observed in mean BCVA, spherical equivalent, or other ocular biometric parameters between groups. CONCLUSION: Modified knotless technique was a valid method to achieve optimal IOL position and reduce postoperative astigmatism for adolescents and young patients with CEL. It effectively reduced the incidence of knot-related complications, greatly improved the postoperative comfort, and achieved aesthetic benefits.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA