Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 187
Filtrar
1.
J Stroke Cerebrovasc Dis ; : 107956, 2024 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-39187217

RESUMEN

OBJECTIVE: To evaluate the efficacy of stereotactic soft-channel and hard-channel aspiration in the treatment of primary brainstem hemorrhage. METHODS: The clinical data of 146 patients with primary brainstem hemorrhage at the First Hospital of Hebei Medical University from August 2014 to August 2023 were analyzed. At admission, 146 patients were divided into soft-channel group or hard-channel group using a random number table method. Sixty-five patients were treated with stereotactic soft-channel aspiration, and 81 patients were treated with stereotactic hard-channel aspiration. The amount of residual hematoma was evaluated by head CT immediately after the operation, and the length of the indwelling drainage tube was recorded. Survival status at 30d after the operation and treatment outcome (mRS score and GOS score) at 90d after the operation were also recorded. The amount of residual hematoma immediately after the operation, the length of the indwelling drainage tube after the operation, the mortality rate and the treatment outcome were compared between the two groups. RESULTS: There was significant difference in the mortality rate 30d after the operation (41.5% vs. 14.8%, χ2=20.192, P=0.035) between stereotactic soft-channel aspiration and stereotactic hard-channel aspiration for brainstem hemorrhage. The hard-channel group had a higher survival rate. There was significant difference in the treatment outcome at 90 days after treatment (18.5% vs. 32.1%, χ2=4.783, P=0.047). The hard-channel group showed better treatment outcomes 90 days after surgery. CONCLUSION: Stereotactic hard-channel aspiration for primary brainstem hemorrhage has greater clearance efficiency than soft-channel aspiration and can significantly reduce patient mortality and improve treatment outcomes. Stereotactic hard-channel aspiration is a safe and effective method for treating primary brainstem hemorrhage.

2.
J Stomatol Oral Maxillofac Surg ; : 101828, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38508394

RESUMEN

OBJECTIVES: The aim of this study is to presents an experimental method for surgical guide confection using an intraoral scanner to obtain a 3D model of the patient's complete denture and compare its accuracy with the conventional methodology using computed tomography. STUDY DESIGN: This prospective in-vitro study used 30 polyurethane pre-manufactured mandibles which were divided into two groups, conventional technique (group I) and a new method using intraoral scanner (group II), establishing the virtually planned position of the dental implants as a control group, considered as the gold standard for postoperative comparison. RESULTS: The difference between these methods is close to zero and not statistically significant (p > 0.05), being heigh deviation (Xh) with p:0.130 and angulation difference of dental implants between the groups (Ang) with p:0.396. CONCLUSION: The acquisition of stereolithography image of the prosthesis using an intraoral scanner has a clinically acceptable accuracy, being in agreement with the conventional method.

4.
J Robot Surg ; 18(1): 91, 2024 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-38401027

RESUMEN

Robotic surgery represents a milestone in surgical procedures, offering advantages such as less invasive methods, elimination of tremors, scaled motion, and 3D visualization. This in-depth analysis explores the complex biochemical effects of robotic methods. The use of pneumoperitoneum and steep Trendelenburg positioning can decrease pulmonary compliance and splanchnic perfusion while increasing hypercarbia. However, robotic surgery reduces surgical stress and inflammation by minimizing tissue trauma. This contributes to faster recovery but may limit immune function. Robotic procedures also limit ischemia-reperfusion injury and oxidative damage compared to open surgery. They also help preserve native antioxidant defenses and coagulation. In a clinical setting, robotic procedures reduce blood loss, pain, complications, and length of stay compared to traditional procedures. However, risks remain, including device failure, the need for conversion to open surgery and increased costs. On the oncology side, there is still debate about margins, recurrence, and long-term survival. The advent of advanced technologies, such as intraoperative biosensors, localized drug delivery systems, and the incorporation of artificial intelligence, may further improve the efficiency of robotic surgery. However, ethical dilemmas regarding patient consent, privacy, access, and regulation of this disruptive innovation need to be addressed. Overall, this review sheds light on the complex biochemical implications of robotic surgery and highlights areas that require additional mechanistic investigation. It presents a comprehensive approach to responsibly maximize the potential of robotic surgery to improve patient outcomes, integrating technical skill with careful consideration of physiological and ethical issues.


Asunto(s)
Laparoscopía , Procedimientos Quirúrgicos Robotizados , Robótica , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Inteligencia Artificial , Quirófanos , Factores de Riesgo , Laparoscopía/métodos
5.
Arch Orthop Trauma Surg ; 144(1): 251-257, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37878075

RESUMEN

INTRODUCTION: The STRYKER ADAPT computer-assisted navigation system provides intraoperative feedback to the surgeon regarding implant placement of the Gamma3 nail. The usability of the ADAPT system has not been evaluated. The aim of the study was to investigate the perceived usability of the ADAPT system. MATERIALS AND METHODS: This was a descriptive study with prospectively collected data. ADAPT was introduced at Aarhus University Hospital in February 2021. Prior to introduction, surgeons at the department attended a general introduction to the system. ADAPT was introduced to the surgical nurses and was on display at the surgical ward at more than one occasion, where personal introduction to the system was possible. After introduction, it was mandatory to use ADAPT when using the Gamma3 nail to treat intertrochanteric femur fractures. After each procedure, primary and an eventual supervisor answered a questionnaire, which encompassed the System Usability Scale (SUS) questionnaire. The SUS is a ten-item questionnaire regarding the perceived usability of a system. SUS scores were translated to adjectives, describing user experience on a 7-point adjective scale (worst imaginable, awful, poor, ok, good, excellent, best imaginable). User acceptability, defined as "not acceptable", "marginal" or "acceptable", was also used to interpret the SUS scores. RESULTS: ADAPT was used in 50 procedures by 29 different surgeons, with varying skill-level. Median SUS-score after first-time use of ADAPT for all 29 surgeons was 43 (range: 5-60), which translated to "poor" or "not acceptable". For surgeons who performed ≥ 3 ADAPT-assisted procedures, there were no statistically significant difference in their first to latest SUS-score (median difference: 4.3, p = 0.5). In free text comments ADAPT was positively described as helpful in placement of K-wire and providing educational opportunities for inexperienced surgeons and negatively as inconsistent, slow, time consuming, and causing excessive fluoroscopy. CONCLUSIONS: Usability and acceptability of ADAPT was rated as "poor" or "not acceptable" by the majority of operating surgeons. ADAPT has not been used at our institution based on these findings. The System Usability Scale may be used in further research exploring usability and acceptability of novel computer-assisted navigation systems for orthopaedic surgery.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Cirujanos , Cirugía Asistida por Computador , Humanos , Tornillos Óseos , Fracturas de Cadera/cirugía , Cirugía Asistida por Computador/métodos , Computadores , Fijación Intramedular de Fracturas/métodos
6.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1024266

RESUMEN

Objective:To investigate the value of digital medical 3D technology versus traditional 2D technology in the diagnosis and treatment of solid abdominal tumors in children. Methods:A total of 80 children with solid abdominal tumors who received surgical treatment guided by digital medical 3D technology at Guigang People's Hospital from January 2018 to January 2022 were included in the observation group. An additional 80 children with solid abdominal tumors who received surgical treatment guided by traditional 2D technology at the same hospital from January 2014 to December 2017 were included in the control group. Clinical efficacy was compared between the two groups.Results:The surgical time, intraoperative blood loss, postoperative exhaust time, postoperative hospital stay in the observation group were (111.8 ± 28.9) minutes, (26.8 ± 25.2) mL, (2.2 ± 1.2) days, (7.5 ± 1.4) days, respectively, which were significantly shorter or less than those in the control group [(193.1 ± 66.0) minutes, (86.2 ± 47.0) mL, (3.7 ± 0.9) days, (12.2 ± 3.5) days, t = 7.00, 6.88, 5.87, 7.53, all P < 0.05]. The complete surgical resection rate in the observation group was significantly higher than that in the control group [92.5% (74/80) vs. 81.3% (65/80), χ2 = 4.44, P < 0.05]. The incidence of complications in the observation group was significantly lower than that in the control group [6.3% (5/80) vs. 16.3% (13/80), χ2 = 4.00, P < 0.05]. Conclusion:The utilization of digital medical 3D technology in the surgical treatment of solid abdominal tumors in children can markedly decrease surgical time, reduce intraoperative blood loss, promote postoperative recovery, achieve a high surgical resection rate, and minimize postoperative complications.

7.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1027090

RESUMEN

Objective:To investigate the efficacy of robot-assisted femoral tunnel localization in reconstruction of the medial patellofemoral ligament (MPFL).Methods:A retrospective study was conducted to analyze the 36 patients who had been admitted to Department of Sports Medicine, The Fourth Hospital of Wuhan between January 2019 and January 2022 due to recurrent patellar dislocation. There were 15 males and 21 females; age: 23.5 (18.3, 29.0) years; number of dislocations: 2.5 (2.0, 3.0). They were stratified into 2 cohorts based on utilization of robot-assistance. In the observation group (17 cases), the femoral tunnel localization was robot-assisted in MPFL reconstruction; in the control group (19 cases), the femoral tunnel localization was guided by C-arm fluoroscopy in MPFL reconstruction. The 2 groups were compared in terms of operation time, frequency of guide wire placement, visual analogue scale (VAS) at postoperative 1 d, patellar tilt angle (PTA) and the disparity between actual femoral tunnel insertion and ideal tunnel insertion point (Sch?ttle point) at postoperative 1 to 3 d, and Lysholm knee score and International Knee Documentation Committee (IKDC) score at the last follow-up.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). All patients were followed up for 12.0 (10.3, 13.0) months. In the observation group, the operation time [(64.1±16.7) min], frequency of guide wire placement [1.0 (1.0, 2.0) times], VAS [2.5 (2.0, 3.0) points], and disparity between actual femoral tunnel insertion and ideal tunnel insertion point [(4.7±1.2) mm] were significantly better than those in the control group [(84.2±19.7) min, 3.0 (2.0, 4.0) times, 3.5 (3.0, 4.0) points, and (6.1±1.2) mm] ( P<0.05). There was no statistical difference between the 2 groups in PTA, Lysholm knee score or IKDC score ( P>0.05). Conclusions:The short-term clinical efficacy of robot-assisted femoral tunnel localization is satisfactory in MPFL reconstruction. Compared with the intraoperative C-arm fluoroscopy, robot-assisted localization can decrease the frequency of guide wire placement, enhance femoral tunnel accuracy and efficiency, and alleviate more postoperative pain for the patients.

8.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1027091

RESUMEN

Objective:To evaluate the reliability of a region-locked 3D-printed template combined with a bi-directional matching scheme in assistance of screw placement for thoracolumbar fractures.Methods:From January 2019 to March 2023, 52 patients with thoracolumbar fracture were treated at Department of Orthopedics, The People's Hospital of Liyang. They were 29 males and 23 females, with an age of (58.2±13.3) years. They were divided into a template group and a free-hand group according to the different screw placements. In the template group of 25 cases, a region-locked 3D-printed template combined with a bi-directional matching scheme was used to assist the pedicle positioning; in the free-hand group of 27 cases, the free hand screw placement was assisted only by image data and C-arm fluoroscopy. The operation time, intraoperative fluoroscopy frequency, intraoperative blood loss, complications, and placement accuracy were compared between the 2 groups. Visual analogue scale (VAS), Oswestry disability index (ODI), and anterior height ratio of the injured vertebra were compared between preoperation, 1 week postoperation, and the final follow-up, as well as between the 2 groups.Results:There were no statistically significant differences in the preoperative general data between the 2 groups, showing comparability ( P>0.05). All patients were followed up for (11.2±4.2) months. The differences were not statistically significant between the 2 groups in intraoperative blood loss, rate of complications, VAS or ODI at preoperation, 1 week postoperation, or the final follow-up, or in anterior height ratio of the injured vertebra ( P>0.05). In the template group, the operation time [(80.1±18.5) min] was significantly longer than that in the free-hand group [(69.4±16.6) min], the intraoperative fluoroscopy frequency [2 (2, 3) times] significantly lower than that in the free-hand group [3 (3, 4) times], and the placement accuracy [98.4% (127/129)] significantly higher than that in the free-hand group [91.8% (112/122)] (all P<0.05). All patients showed significant improvements in VAS, ODI and anterior height ratio of the injured vertebra at postoperative 1 week compared with the preoperative values, and the improvements at the last follow-up were significantly larger than those at postoperative 1 week ( P<0.05). No injury to the spinal cord, nerve root or blood vessel was observed postoperatively. Conclusions:In the treatment of thoracolumbar fractures, the screw placement assisted by a region-locked 3D-printed template combined with a bi-directional matching scheme is better than free-hand screw placement in terms of improved accuracy and reduced fluoroscopy, but the former incurs longer operative exposure than the latter. There is no significant difference between the 2 methods of screw placement in clinical efficacy.

9.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1027092

RESUMEN

Objective:To compare the efficacy of pedicle screw placement between computer navigation guidance and freehand assistance in the surgical treatment of isthmic spondylolysis at the lumbar vertebrae.Methods:A retrospective study was conducted to analyze the 47 patients with bilateral isthmic spondylolysis at the L 5 vertebra who had been treated at Department of Spinal Surgery, The General Hospital of Xinjiang Military Command from January 2020 to April 2023. All were male patients with an age of (24.0±4.3) years. They were divided into a study group (13 cases subjected to pedicle screw placement assisted by computer navigation guidance) and a control group (34 cases subjected to pedicle screw placement assisted freehandedly). The 2 groups were compared in terms of surgical incision length, intraoperative bleeding, screw placement time, postoperative hospital stay, total hospitalization cost, postoperative complications, rate of screw reposition, angle between pedicle screw and upper endplate, angle between bilateral pedicle screws, and placement accuracy; the visual analogue scale (VAS) for pain, Japanese Orthopaedic Association (JOA) score for lumbar spine function, and Oswestry disability index (ODI) were also compared between preoperation, 1-week postoperation, and the last follow-up. Patient satisfaction was assessed according to the modified MacNab criteria, and internal fixation failure and isthmic healing were also evaluated at the last follow-up. Results:There were no statistically significant differences in the preoperative general data between the 2 groups, showing comparability ( P>0.05). The differences were not statistically significant in surgical incision length, intraoperative bleeding, screw placement time, postoperative hospital stay, or postoperative complications ( P>0.05). However, in the study group, the total hospitalization cost was significantly higher than that in the control group, the rate of screw reposition [7.7% (2/26)] significantly lower than that in the study group [26.5% (18/68)], the angle between pedicle screw and upper endplate and the angle between bilateral pedicle screws were both significantly smaller than those in the control group, and the placement accuracy [92.3% (24/26)] was significantly greater than that [70.6% (48/68)] in the control group (all P<0.05). All patients were followed up for 7.0 (5.0, 14.0) months. Patients in both groups showed significant improvements in VAS, JOA score, and ODI at postoperative 1 week and the last follow-up compared with the preoperative values, and the improvements at the last follow-up were significantly larger than those at postoperative 1 week ( P<0.05). According to the modified MacNab criteria at the last follow-up, patient satisfaction was rated as excellent in 10 cases, as good in 2 cases and as moderate in 1 case in the study group while as excellent in 27 cases, as good in 3 cases, as moderate in 3 cases and as poor in 1 case in the control group. In the study group, there were 1 case of internal fixation failure, 1 case of spine cutting-out by titanium cable, and 12 cases of bony healing of the isthmus; in the control group, there were 2 cases of internal fixation failure, 2 cases of spine cutting-out by titanium cable, and 29 cases of bony healing of the isthmus. Conclusions:In the surgical treatment of bilateral isthmic spondylolysis at the L 5 vertebra, computer navigation-guided pedicle screw placement is safe and reliable, showing an advantage of higher accuracy over freehand placement. It deserves clinical promotion due to its satisfactory therapeutic effects.

10.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1027095

RESUMEN

Digital intelligence technologies, including artificial intelligence, big data, surgical navigation, surgical robots, and virtual reality, have been widely used in basic and clinical research in trauma and orthopedics. In order to provide trauma orthopedists with a quick overview of the current application of these technologies, this paper elaborates on the orthopedic workflow of fracture open reduction and internal fixation, on the aspects of recognition and classification of fracture X-ray images, fracture fragment segmentation based on thin-slice CT images, virtual fracture reduction, 3D fracture line heatmaps, design of an anatomical locking plate, intelligent navigation and orthopedic surgical robots, fracture reduction robots, and surgical process visualization.

11.
J Stomatol Oral Maxillofac Surg ; 125(3): 101683, 2023 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-37951500

RESUMEN

OBJECTIVE: This systematic review and meta-analysis aimed to review the recent literature on the technical accuracy of surgical navigation for patient-specific reconstruction of orbital fractures using a patient-specific implant, and to compare surgical navigation with conventional techniques. MATERIALS AND METHODS: A systematic literature search was conducted in PubMed (Medline), Embase, Web of Science, and Cochrane (Core Collection) databases on May 16, 2023. Literature comparing surgical navigation with a conventional method using postoperative three-dimensional computed tomography imaging was collected. Only articles that studied at least one of the following outcomes were included: technical accuracy (angular accuracy, linear accuracy, volumetric accuracy, and degree of enophthalmos), preoperative and perioperative times, need for revision, complications, and total cost of the intervention. MINORS criteria were used to evaluate the quality of the articles. RESULTS: After screening 3733 articles, 696 patients from 27 studies were included. A meta-analysis was conducted to evaluate volumetric accuracy and revision rates. Meta-analysis proved a significant better volumetric accuracy (0.93 cm3 ± 0.47 cm3) when surgical navigation was used compared with conventional surgery (2.17 cm3 ± 1.35 cm3). No meta-analysis of linear accuracy, angular accuracy, or enophthalmos was possible due to methodological heterogeneity. Surgical navigation had a revision rate of 4.9%, which was significantly lower than that of the conventional surgery (17%). Costs were increased when surgical navigation was used. CONCLUSION: Studies with higher MINORS scores demonstrated enhanced volumetric precision compared with traditional approaches. Surgical navigation has proven effective in reducing revision rates compared to conventional approaches, despite increased costs.

12.
J Robot Surg ; 17(6): 3035-3038, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37610537

RESUMEN

The Versius Surgical System is a next generation soft-tissue robot with instrument and endoscope arms split into individual modules. Despite its similarities with previous systems, the basic changes in the design raise concerns relating to the feasibility of the set-up for the different approaches in robotic head and neck surgery procedures. We used a complete unit with a surgeon's console and four modules on a training mannequin to depict the different configurations in the operating room. We tested transoral robotic surgery and the four basic configurations for the remote access to the neck: transoral/transvestibular, retroauricular, axillary and bilateral axillo-breast approaches. We obtained a high quality simulation for transoral robotic surgery, as well as for the usual remote access approaches, except for the axillary approach. We were able to obtain an optimal distribution of the modules around the surgical table and an adequate configuration of the joints allowing the instruments to reach their targets. The Versius Surgical System might be an alternative device for robotic procedures in head and neck surgery, although this needs to be proved in a clinical setting.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Robótica , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios de Factibilidad , Tiroidectomía/métodos , Cadáver
13.
Clin Oral Investig ; 27(7): 3907-3915, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37083986

RESUMEN

OBJECTIVES: To assess the surgical accuracy of 3D virtual surgical planned orthognathic surgery and the influence of posterior impaction and magnitude of the planned movements on a possible learning curve. MATERIALS AND METHODS: This prospective cohort study included subjects who underwent bimaxillary surgery between 2016 and 2020 at the Department of Oral and Maxillofacial Surgery of the Radboud University Medical Center, Nijmegen. 3D virtual surgical planning (VSP) was performed with CBCT data and digitalized dentition data. By using voxel-based matching with pre- and postoperative CBCT data the maxillary movements were quantified in six degrees of freedom. The primary outcome variable, surgical accuracy, was defined as the difference between the planned and achieved maxillary movement. RESULTS: Based on 124 subjects, the surgical accuracy increased annually from 2016 to 2020 in terms of vertical translations (0.82 ± 0.28 mm; p = 0.038) and yaw rotations (0.68 ± 0.22°; p = 0.028). An increase in surgical accuracy was observed when combining all six degrees of freedom (p = 0.021) and specifically between 2016 and 2020 (p = 0.004). An unfavorable learning curve was seen with posterior impaction and with a greater magnitude of movements. CONCLUSION: The present study demonstrated a significant increase in surgical accuracy annually and therefore supports the presence of a learning curve. CLINICAL RELEVANCE: Cases with planned maxillary posterior impaction and/or a great magnitude of jaw movements should be transferred from the 3D VSP with extra care to obtain a satisfactory surgical accuracy.


Asunto(s)
Cirugía Ortognática , Procedimientos Quirúrgicos Ortognáticos , Cirugía Asistida por Computador , Humanos , Curva de Aprendizaje , Estudios Prospectivos , Imagenología Tridimensional , Maxilar/cirugía
14.
Clin Neurol Neurosurg ; 228: 107684, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36996673

RESUMEN

BACKGROUND: 3-dimensional (3D) printing carries a genuine potential for pre-operative planning in neurosurgery. Entry-level 3D printers offer practicality in low resource settings, but are often limited by the range of filament materials as well as the capability of open-source segmentation software. OBJECTIVE: We intended to demonstrate that 3D printing of neuroanatomical structures is possible using an entry-level 3D printer equipped with the direct drive (DD) modification, which supported flexible filaments, with the models segmented using an open-source software. METHODS: A DD system was installed onto the Ender 3 Pro printer. An attempt to print neurosurgical models using a low-cost 3D printer was conducted, where four patient-based neuroanatomical models were printed: skull base-vasculature, skull base-tumour, cervical spine, and ventricular system. The results were discussed and compared to similar endeavours in past literature. RESULTS: Although DD installation was challenging and led to vibration and longer print time, which ultimately warranted an inferior printing speed, DD system enabled the printing with thermoplastic polyurethane (TPU), a versatile elastomer; in addition to producing equal amount of detail to those printed with high-end printers and advanced image segmentation software. Fitting the frame well, changing infill type, and avoiding warping and stringing will improve print quality with the DD system. CONCLUSION: 3D printing with entry-level 3D printers equipped with DD system has been proven to be a reliable way of accurately reproducing patient-specific neuroanatomical constructs. Follow-up studies are necessary to implement 3D printing for neurosurgical planning in low-resource settings.


Asunto(s)
Neurocirugia , Humanos , Impresión Tridimensional , Programas Informáticos , Base del Cráneo , Neuroanatomía
15.
Unfallchirurgie (Heidelb) ; 126(2): 89-99, 2023 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-36645450

RESUMEN

Acetabular fractures still pose a special challenge even today. Considering the increasing case numbers, especially in the geriatric patient group, modern imaging examination procedures represent an essential pillar of the diagnostics. Especially in this vulnerable patient group, minimally invasive methods are necessary, which can be guaranteed by intraoperative navigation; however, the choice of surgical access and implants is also made based on the existing morphological characteristics of fractures, which highlights the importance of an imaging modality that is as detailed as possible. Last but not least, new developments concerning the surgical treatment of these injuries are also based on this. This article summarizes the current state of the techniques and the available literature.


Asunto(s)
Fracturas de Cadera , Cirugía Asistida por Computador , Humanos , Anciano , Fijación Interna de Fracturas/métodos , Cirugía Asistida por Computador/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Acetábulo/diagnóstico por imagen , Fracturas de Cadera/cirugía
16.
Periodontol 2000 ; 91(1): 89-112, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35906928

RESUMEN

Flapless and fully guided implant placement has the potential to maximize efficacy outcomes and at the same time to minimize surgical invasiveness. The aim of the current systematic review was to answer the following PICO question: "In adult human subjects undergoing dental implant placement (P), is minimally invasive flapless computer-aided fully guided (either dynamic or static computer-aided implant placement (sCAIP)) (I) superior to flapped conventional (free-handed implant placement (FHIP) or cast-based/drill partially guided implant placement (dPGIP)) surgery (C), in terms of efficacy, patient morbidity, long-term prognosis, and costs (O)?" Randomized clinical trials (RCTs) fulfilling specific inclusion criteria established to answer the PICO question were included. Two review authors independently searched for eligible studies, screened the titles and abstracts, performed full-text analysis, extracted the data from the published reports, and performed the risk of bias assessment. In cases of disagreement, a third review author took the final decision during ad hoc consensus meetings. The study results were summarized using random effects meta-analyses, which were based (wherever possible) on individual patient data (IPD). A total of 10 manuscripts reporting on five RCTs, involving a total of 124 participants and 449 implants, and comparing flapless sCAIP with flapped FHIP/cast-based partially guided implant placement (cPGIP), were included. There was no RCT analyzing flapless dynamic computer-aided implant placement (dCAIP) or flapped dPGIP. Intergroup meta-analyses indicated less depth deviation (difference in means (MD) = -0.28 mm; 95% confidence interval (CI): -0.59 to 0.03; moderate certainty), angular deviation (MD = -3.88 degrees; 95% CI: -7.00 to -0.77; high certainty), coronal (MD = -0.6 mm; 95% CI: -1.21 to 0.01; low certainty) and apical (MD = -0.75 mm; 95% CI: -1.43 to -0.07; moderate certainty) three-dimensional bodily deviations, postoperative pain (MD = -17.09 mm on the visual analogue scale (VAS); 95% CI: -33.38 to -0.80; low certainty), postoperative swelling (MD = -6.59 mm on the VAS; 95% CI: -19.03 to 5.85; very low certainty), intraoperative discomfort (MD = -9.36 mm on the VAS; 95% CI: -17.10 to -1.61) and surgery duration (MD = -24.28 minutes; 95% CI: -28.62 to -19.95) in flapless sCAIP than in flapped FHIP/cPGIP. Despite being more accurate than flapped FHIP/cPGIP, flapless sCAIP still resulted in deviations with respect to the planned position (intragroup meta-analytic means: 0.76 mm in depth, 2.57 degrees in angular, 1.43 mm in coronal, and 1.68 in apical three-dimensional bodily position). Moreover, flapless sCAIP presented a 12% group-specific intraoperative complication rate, resulting in an inability to place the implant with this protocol in 7% of cases. Evidence regarding more clinically relevant outcomes of efficacy (implant survival and success, prosthetically and biologically correct positioning), long-term prognosis, and costs, is currently scarce. When the objective is to guarantee minimal invasiveness at implant placement, clinicians could consider the use of flapless sCAIP. A proper case selection and consideration of a safety margin are, however, suggested.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Adulto , Humanos , Implantación Dental Endoósea/métodos , Colgajos Quirúrgicos
17.
Chinese Journal of Trauma ; (12): 138-144, 2023.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-992581

RESUMEN

Objective:To investigate the effect of open reduction and internal fixation assisted by computer virtual surgery in the treatment of complex proximal humeral fracture.Methods:A retrospective case series study was performed on clinical data of 36 patients with complex proximal humeral fracture admitted to Dongfang Hospital Affiliated to Tongji University from January 2018 to June 2020. There were 13 males and 23 females, aged 22-86 years [(56.4±4.8)years]. They were all closed fractures. According to Neer classification, there were 20 patients with three-part fractures and 16 with four-part fractures. Precise pre-surgical designs made by using the digital orthopedic surgery planning system of the E-3D were applied to assist the implementation of precise fracture reduction and internal fixation with the locking plate. The fracture healing was observed. The effect of the real surgery assisted by the virtual surgical designs was assessed by comparing the humeral neck shaft angle and humeral head height measured at the virtual surgery and at day 1 after the real surgery. The humeral neck shaft angle, humeral head height, shoulder range of motion (abduction, external rotation and forward flexion), Constant shoulder function score and visual analogue score (VAS) were recorded at 1 day, 3 months and 12 months after the real surgery. The stability of the medial column was assessed at 1 day after the real surgery. The complications were recorded.Results:All patients were followed up for 12-38 months [(18.5±1.8)months]. The fracture showed bony union in all patients with the union time of 6.6-17.2 weeks [(10.2±1.0)weeks]. The humeral neck shaft angle and humeral head height showed no significant differences measured at the virtual surgery and at 1 day after the real surgery, and were also not significant different at 1 day, 3 months and 12 months after the real surgery (all P>0.05). At 3 months and 12 months after the real surgery, the shoulder abduction [(119.4±11.8)°, (155.3±13.7)°], external rotation [(37.6±6.3)°, (46.8±7.4)°], forward flexion [ (94.8±10.2)°, (126.9±1.6)°] and Constant function score [(66.8±8.4)points, (82.4±9.6)points] were all higher than those at 1 day after the real surgery [(53.8±4.5)°, (21.6±3.3)°, (44.6±7.8)°, (34.3±6.1)points], while the VAS [(4.1±0.5)points, (1.2±0.2)points] was lower than that at 1 day after the real surgery [(8.3±1.4)points] (all P<0.05). The medial column was stable in 34 patients and unstable in 2 at 1 day after the real surgery. Complications included screw cutting out in the articular surface in 1 patient and humeral head necrosis in 1. Conclusion:Treatment of complex proximal humeral fractures with open reduction and internal fixation assisted by computer virtual surgery is conducive to maintaining reduction effect, promoting shoulder joint function, relieving pain and reducing complications.

18.
Chinese Journal of Trauma ; (12): 763-768, 2023.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-992660

RESUMEN

Orbital fracture often leads to facial collapse, diplopia, enophthalmos, and even blindness. Traditional surgery relies on the experiences of physicians to achieve fracture reduction and orbital wall reconstruction, but the repair effect is not satisfactory. In recent years, with the development of digital technology, technologies such as computer-assisted surgery, 3D printing, surgical navigation systems, and intraoperative CT imaging have become increasingly widespread in the field of orbital reconstruction. Such techniques can avoid dependence on physicians′ experiences and make it easy for estimating and positioning the implantation sites, which subsequently contributes to better surgery efficiency and precise reconstruction of the orbit, improving aesthetics and visual function of patients. To this end, the authors reviewed the recent progress in application of digital technology for orbital fracture reconstruction, so as to provide reference and theoretical basis for clinical practice.

19.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-993410

RESUMEN

Objective:To investigate the clinical efficacy of preoperative three-dimensional (3D) reconstruction planning in total hip arthroplasty for development dysplasia of the hip secondary to osteoarthritis.Methods:A total of 80 patients with osteoarthritis secondary to Crowe I-III developmental dysplasia of the hip who underwent primary unilateral total hip arthroplasty from October 2019 to March 2021 were retrospectively analyzed, including 18 males and 62 females and the mean age was 55.7±10.4 years (range 41-72 years). Forty patients in the 3D group, the prosthesis type and installation angle were planed on the 3D reconstruction software based on the full-length CT scan data of the lower limbs, and the length difference of the lower limbs and hip offset were calculated. Forty patients in the control group underwent preoperative planning using conventional film measurement, and lower limb length was judged based on the preoperative measurement data and intraoperative comparison of both lower limbs. The difference of postoperative leg length, hip offset, hip function score, operating time, intraoperative blood loss, and incidence of complications were compared between the two groups.Results:All 80 patients completed the surgery successfully and the follow-up time was up to 3 months after operation. The 3D group was better than the control group in operation time (70.9±7.7 min vs. 81.6±13.3 min, t=-4.91, P<0.001), the difference of postoperative lower limb length (2.78±1.31 cm vs. 5.35±2.15 cm, t=-5.74, P<0.001), and hip function score at 1 week after operation (75.67±3.35 vs. 67.35±4.21, t=12.33, P=0.002), with statistically significant differences. In the 3D group, 95% of acetabular prosthesis and 90% of femoral stem components were consistent with the planned model, while the rate were only 75% and 68% in the control group, and the difference was statistically significant (χ 2=7.51, P=0.023; χ 2=14.92, P=0.005). There were no intraoperative complications such as vascular and nerve injury, and no postoperative complications such as dislocation or periprosthetic infection in all 80 patients. Conclusion:3D preoperative planning assisted total hip arthroplasty in the treatment of Crowe I-III developmental dysplasia of the hip secondary to osteoarthritis can improve the accuracy of the operation, and has a good clinical effect on restoring the leg length and hip offset.

20.
Chinese Journal of Orthopaedics ; (12): 104-111, 2023.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-993416

RESUMEN

Objective:To explore the role of navigation-assisted valgus stress method in avoiding excessive correction of lower limb mechanical axis after high tibial osteotomy (HTO).Methods:A retrospective study was carried out on osteoarthritis (OA) patients who were treated with HTO for medial compartment pain of knee from January 2020 to March 2022 in the Department of Joint Surgery, Shanghai Changhai Hospital, the First Affiliated Hospital of Naval Medical University. According to the different ways of confirming alignment during operation, they were divided into computer navigation assisted valgus stress HTO group (referred to as navigation group) and traditional rod fluoroscopy HTO group (referred to as traditional group). There were 28 patients in the navigation group, 10 males and 18 females, with age of 54.4±9.1 years (range, 41-73 years) and body mass index of 26.1±3.3 kg/m 2 (range, 19.8-35.2 kg/m 2); There were 30 patients in the traditional group, 13 males and 17 females, aged 56.9±8.5 years (range, 40-70 years), with a body mass index of 25.7±4.0 kg/m 2 (range, 19.2-32.9 kg/m 2). Measuring the mechanical femoral tibial angle (mFTA), joint line convergence angle (JLCA), medial proximal tibial angle (MPTA), Lysholm score and Hospital for Special Surgery (HSS) score before operation and at the last follow-up of the two groups, and conduct statistical analysis. Results:Both groups were followed up. The follow-up time of navigation group and traditional group was 21.3±8.7 months and 22.5±7.6 months, respectively, with no significant difference ( t=0.53, P=0.596). There were significant differences between the two groups in the amount of mechanical axis correction (ΔmFTA) and the amount of bone correction (ΔMPTA) ( t=2.09, P=0.041; t=2.58, P=0.012), while there was no significant difference in ΔJLCA ( t=0.32, P=0.753). In the navigation group, there were 9 cases (32%) of undercorrection, 17 cases (61%) with acceptable alignment, and 2 cases (7%) with over correction, while in the traditional group, there were 5 cases (17%) with under correction, 13 cases (43%) with acceptable alignment, and 12 cases (40%) with over correction. There was significant difference in the distribution rate of alignment between the two groups ( P=0.012), and the rate of overcorrection in the navigation group was significantly lower than that in the control group (7% vs. 40%, P=0.005). The intra group correlation coefficient between the navigation correction mechanical axis and ΔmFTA was 0.787. There was no significant difference in Lysholm score and HSS score between the two groups before and after surgery (all P>0.05), and they were significantly improved after operation (all P<0.05). Conclusion:Navigation-assisted valgus stress method HTO is reliable, which can accurately achieve the target alignment, reduce the incidence of over correction, and obtain good clinical results.