Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Int Ophthalmol ; 44(1): 354, 2024 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-39182211

RESUMEN

PURPOSE: We aimed to evaluate distance stereoacuity (DS) in patients with successfully treated accommodative esotropia (AET) and its association with other clinical factors. METHODS: The medical records of 176 children with refractive AET with a follow-up period ≥ 1 year were reviewed to identify a cohort of patients who achieved a stable alignment within 4 prism diopters (PD) of orthotropia at both distance and near fixation. Age of onset, duration of misalignment, uncorrected near and distance deviation, accommodative convergence/accommodation ratio, refractive error, presence of anisometropia and amblyopia, near stereopsis were evaluated as predictors of outcome. DS was measured using the Distance Randot Stereo test and near stereoacuity by Randot Stereotest. The patient group was compared with 50 age-matched normal controls for DS. RESULTS: Fifty-six patients were included, and 38 patients had DS at the final visit. All patients with DS attained uncontoured near stereopsis (UCNS). UCNS was present only in 11 patients without DS (p = 0.001). Anisometropia (p = 0.997), uncorrected near deviation (p = 0.224), distance deviation with correction (p = 0.255), and high hypermetropia (p = 0.998) were not associated with DS. The multivariable regression model showed a significant positive correlation between UCNS and DS (OR = 31.14 (95% CI 2.25-430.48); p = 0.01). Contoured near stereopsis outcome was significantly different between the patients with and without DS (p = 0.001 for animals and p = 0.003 for circles). Compared with the control group, the patient group yielded lower DS scores (p = 0.001). CONCLUSION: Distance Randot Stereotest can be useful in measuring binocular vision recovery after successful realignment in refractive AET patients. Patients attaining normal scores for near stereopsis tests after optical correction revealed subnormal thresholds for DS.


Asunto(s)
Acomodación Ocular , Percepción de Profundidad , Esotropía , Visión Binocular , Agudeza Visual , Humanos , Esotropía/fisiopatología , Esotropía/terapia , Esotropía/diagnóstico , Masculino , Percepción de Profundidad/fisiología , Femenino , Acomodación Ocular/fisiología , Agudeza Visual/fisiología , Niño , Preescolar , Estudios Retrospectivos , Visión Binocular/fisiología , Estudios de Seguimiento , Adolescente
2.
Strabismus ; 31(3): 188-196, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37705215

RESUMEN

Background: A clinician's choice of stereotest is influenced by the robustness of the measurement, in terms of sensitivity, specificity and test-retest variability. In relation to the latter aspect, there are limited data on the test-retest variability of these new tests and how they compare to the more commonly used stereotests. Therefore, the aim of the study was to determine the test-retest variability of four different measures of stereoacuity (TNO, Frisby, Lang Stereopad and Asteroid (Accurate STEReotest On a mobIle Device)) and to compare the stereoacuity measurements between the tests in an adult population. Methods: Stereoacuity was measured twice using TNO, Frisby, Lang Stereopad and Asteroid. Inclusion criteria included adult participants (18 years and older), no known ophthalmic condition and VA (Visual Acuity) equal to or better than 0.3 logMAR (Logarithm of the Minimum Angle of Resolution) with interocular difference of less than 0.2 logMAR. Bland-Altman analysis was used to assess agreement within and between stereotests. Differences in stereo thresholds were compared using signed Wilcoxon tests. Results: Fifty-four adults (male: 23 and female: 31) with VA equal to or better than 0.3 logMAR in either eye and interocular difference less than 0.2 logMAR were assessed (mean age: 38 years, SD: 12.7, range: 18-72). The test-retest variability of all the clinical stereotests, with the exception of the Lang Stereopad (p = .03, Wilcoxon signed-rank test), was clinically insignificant as the mean bias was equal or less than 0.06 log seconds of arc (equivalent to 1.15 seconds of arc). While the Asteroid test had the smallest variation between repeated measures (mean bias: -0.01 log seconds of arc), the Frisby and Lang Stereopad tests had the narrowest and widest limits of agreement respectively. When comparing results between tests, the biggest mean bias was between Frisby and Lang Stereopad (-0.62 log seconds of arc), and 64.8% and 31.5% of differences were in the medium (21-100" of arc) and larger (>100" of arc) ranges respectively. Conclusion: The TNO and Frisby tests have good reliability but measure stereoacuity over a narrower range compared to the Asteroid which shows less variation on repeated testing but has a larger testing range. The data reported here show varying degrees of agreement in a cohort of visually normal participants, and further investigation is required to determine if there is further variability when stereoacuity is reduced.


Asunto(s)
Percepción de Profundidad , Pruebas de Visión , Adulto , Humanos , Masculino , Femenino , Pruebas de Visión/métodos , Visión Binocular , Reproducibilidad de los Resultados , Agudeza Visual
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA