Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Quant Imaging Med Surg ; 14(9): 6792-6805, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39281131

RESUMEN

Background: With the advances in medical technology and materials, thoracic endovascular aortic repair has become the mainstay of treatment for aortic dissection. In situ fenestration (ISF) and single-branch stent graft (SBSG) implantation are commonly used methods, with each having its own advantages and disadvantages. The study aimed to compare the perioperative outcomes and one-year follow-up results of patients who underwent ISF or SBSG in the treatment of acute Stanford type B aortic dissection involving the left subclavian artery (LSA). Methods: From January 2018 to December 2022, consecutive patients with Stanford type B aortic dissection were retrospectively recruited and divided into ISF group and SBSG group according to the type of surgery. The patient's aortic physiology was evaluated by computed tomography angiography at 1, 3, 6, and 12 months after discharge. Results: This study included 67 patients in the SBSG group and 21 patients in the ISF group. The baseline and preoperative indices were similar between the groups. The success rate of perioperative treatment was 100%, and no adverse consequences occurred in either group. No spinal cord ischemia, stroke, or paraplegia occurred in either group during the one-year follow-up. The rate of endoleak in the SBSG group was significantly lower (3%, all type I endoleaks) than that in the ISF group (9.5% type I and 14.3% type II endoleaks) (P=0.005). Type II endoleak mainly occurred in the LSA. In addition, complete thrombosis of the false lumen was achieved in 95.5% of the SBSG group versus 81.0% of the ISF group, but this was not a significant difference (P=0.091). The maximum diameter of the true lumen increased significantly in the ISF (P<0.001) and SBSG (P<0.001) groups. Meanwhile, the maximum diameter of the false lumen was significantly reduced in the ISF (P<0.001) and SBSG (P<0.001) groups, but the difference in the maximum diameter change of the true or false lumen between the two groups was not statistically significant (P>0.05). Conclusions: SBSG was associated with a significantly lower incidence of endoleak than was ISF. However, there were no differences observed in complete thrombosis of the false lumen. Further studies with larger sample sizes are needed to definitively establish which treatment is superior in terms of complete thrombosis of the false lumen.

2.
Hellenic J Cardiol ; 2024 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-39128706

RESUMEN

OBJECTIVE: Aortic dissection remains a life-threatening condition necessitating accurate diagnosis and timely intervention. This study aimed to investigate phenotypic heterogeneity in patients with Stanford type B aortic dissection (TBAD) through machine learning clustering analysis of cardiovascular computed tomography (CT) imaging. METHODS: Electronic medical records were collected to extract demographic and clinical features of patients with TBAD. Exclusion criteria ensured homogeneity and clinical relevance of the TBAD cohort. Controls were selected on the basis of age, comorbidity status, and imaging availability. Aortic morphological parameters were extracted from CT angiography and subjected to K-means clustering analysis to identify distinct phenotypes. RESULTS: Clustering analysis revealed three phenotypes of patients with TBAD with significant correlations with population characteristics and dissection rates. This pioneering study used CT-based three-dimensional reconstruction to classify high-risk individuals, demonstrating the potential of machine learning in enhancing diagnostic accuracy and personalized treatment strategies. Recent advancements in machine learning have garnered attention in cardiovascular imaging, particularly in aortic dissection research. These studies leverage various imaging modalities to extract valuable features and information from cardiovascular images, paving the way for more personalized interventions. CONCLUSION: This study provides insights into the phenotypic heterogeneity of patients with TBAD using machine learning clustering analysis of cardiovascular CT imaging. The identified phenotypes exhibit correlations with population characteristics and dissection rates, highlighting the potential of machine learning in risk stratification and personalized management of aortic dissection. Further research in this field holds promise for improving diagnostic accuracy and treatment outcomes in patients with aortic dissection.

3.
Heart Vessels ; 39(8): 746-753, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38592490

RESUMEN

The use of thoracic endovascular aortic repair (TEVAR) for thoracic aortic aneurysm (TAA) and Stanford type B aortic dissection (TBAD) has been increasing; however, in terms of etiology, the differences of long term after TEVAR outcomes remain unexplored. Thus, we investigated etiology-specific long-term results of TEVAR for TAA and TBAD. A total of 421 TEVAR procedures were performed at our institution from July 2007 to December 2021; 249 TAA cases and 172 TBAD cases were included. Traumatic aortic dissection and aortic injury cases were excluded. The mean observation duration was 5.7 years. The overall 30-day mortality rate was 1.4% (n = 6), with 1.2% (n = 3) in the TAA group and 1.7% (n = 3) in the TBAD group. The overall incidence of postoperative stroke was 0.9% (n = 4), with 1.2% (n = 3) and 0.6% (n = 1) in the TAA and TBAD groups, respectively (p = 0.90). Paraplegia developed in 1.7% (n = 7) of patients, with 2.4% (n = 6) in the TAA group and 0.6% (n = 1) in the TBAD group. Freedom from aortic-related death was not significantly different between the two etiologies; however, thoracic reintervention was more common in the TBAD group (p = 0.003), with endoleak being the most common indication for reintervention. Additionally, retrograde type A aortic dissection occurred in four TBAD cases, while migration occurred in three TAA cases. The perioperative results of TEVAR for TAA and TBAD were satisfactory. The long-term results were unfavorable owing to the occurrence of etiology-specific and common complications. In terms of the high frequency of reintervention, the long-term complications associated with TEVAR are etiology specific.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Reparación Endovascular de Aneurismas , Complicaciones Posoperatorias , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Aorta Torácica/cirugía , Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico , Aneurisma de la Aorta Torácica/mortalidad , Disección Aórtica/cirugía , Disección Aórtica/mortalidad , Reparación Endovascular de Aneurismas/efectos adversos , Reparación Endovascular de Aneurismas/métodos , Estudios de Seguimiento , Incidencia , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
Front Cardiovasc Med ; 11: 1324345, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38476381

RESUMEN

Objective: Cell division cycle 42 (CDC42) regulates CD4+ T-cell differentiation and participates in vascular stiffness and atherosclerosis and is involved in the progression of Stanford type B aortic dissection (TBAD). This study aimed to explore the correlation between serum CDC42 level and CD4+ T cell subsets and in-hospital mortality in TBAD patients. Methods: Serum CDC42 and peripheral blood T-helper (Th) 1, Th2, and Th17 cells were detected in 127 TBAD patients by enzyme-linked immunosorbent assay and flow cytometry, respectively. Serum CDC42 was also quantified in 30 healthy controls. Results: Serum CDC42 was decreased in TBAD patients vs. healthy controls (median [interquartile range (IQR)]: 418.0 (228.0-761.0) pg/ml vs. 992.0 (716.3-1,445.8) pg/ml, P < 0.001). In TBAD patients, serum CDC42 was negatively correlated with Th17 cells (P = 0.001), but not Th1 (P = 0.130) or Th2 cells (P = 0.098). Seven (5.5%) patients experienced in-hospital mortality. Serum CDC42 was reduced in patients who experienced in-hospital mortality vs. those who did not (median (IQR): 191.0 (145.0-345.0) pg/ml vs. 451.5 (298.3-766.8) pg/ml, P = 0.006). By receiver operating characteristic analysis, serum CDC42 showed a good ability for estimating in-hospital mortality [area under curve = 0.809, 95% confidence interval (CI) = 0.662-0.956]. By the multivariate logistic regression analysis, elevated serum CDC42 [odd ratio (OR) = 0.994, 95% CI = 0.998-1.000, P = 0.043] was independently correlated with lower risk of in-hospital mortality, while higher age (OR = 1.157, 95% CI = 1.017-1.316, P = 0.027) was an independent factor for increased risk of in-hospital mortality. Conclusion: Serum CDC42 negatively associates with Th17 cells and is independently correlated with decreased in-hospital mortality risk in TBAD patients.

5.
BMC Cardiovasc Disord ; 24(1): 124, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38408908

RESUMEN

BACKGROUND: This study aims to compare the clinical effects of two distinct surgical approaches, namely 3D printing-assisted extracorporeal pre-fenestration and Castor integrated branch stent techniques, in treating patients with Stanford type B aortic dissections (TBAD) characterized by inadequate proximal landing zones. METHODS: A retrospective analysis was conducted on 84 patients with type B aortic dissection (TBAD) who underwent thoracic endovascular aortic repair (TEVAR) with left subclavian artery (LSA) reconstruction at our center from January 2022 to July 2023. Based on the different surgical approaches, the patients were divided into two groups: the group assisted by 3D printing for extracorporeal pre-fenestration (n = 44) and the group using the castor integrated branch stent (n = 40). Clinical indicators: including general patient information, operative time, surgical success rate, intraoperative and postoperative complication rates, re-intervention rate, and mortality, as well as postoperative aortic remodeling, were compared between the two groups. The endpoint of this study is the post-TEVAR mortality rate in patients. RESULTS: The surgical success rate and device deployment success rate were 100% in both groups, with no statistically significant difference (P > 0.05). However, the group assisted by 3D printing for extracorporeal pre-fenestration had a significantly longer operative time (184.20 ± 54.857 min) compared to the group using the castor integrated branch stent (152.75 ± 33.068 min), with a statistically significant difference (t = 3.215, p = 0.002, P < 0.05). Moreover, the incidence of postoperative cerebral infarction and beak sign was significantly lower in the group assisted by 3D printing for extracorporeal pre-fenestration compared to the castor-integrated branch stent group, demonstrating statistical significance. There were no significant differences between the two groups in terms of other postoperative complication rates and aortic remodeling (P > 0.05). Notably, computed tomography angiography images revealed the expansion of the vascular true lumen and the reduction of the false lumen at three specified levels of the thoracic aorta. The follow-up duration did not show any statistically significant difference between the two groups (10.59 ± 4.52 vs. 9.08 ± 4.35 months, t = 1.561, p = 0.122 > 0.05). Throughout the follow-up period, neither group experienced new endoleaks, spinal cord injuries, nor limb ischemia. In the castor-integrated branch stent group, one patient developed a new distal dissection, prompting further follow-up. Additionally, there was one case of mortality due to COVID-19 in each group. There were no statistically significant differences between the two groups in terms of re-intervention rate and survival rate (P > 0.05). CONCLUSION: Both 3D printing-assisted extracorporeal pre-fenestration TEVAR and castor-integrated branch stent techniques demonstrate good safety and efficacy in treating Stanford type B aortic dissection with inadequate proximal anchoring. The 3D printing-assisted extracorporeal pre-fenestration TEVAR technique has a lower incidence of postoperative cerebral infarction and beak sign, while the castor-integrated branch stent technique has advantages in operative time.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Factores de Tiempo , Stents/efectos adversos , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Complicaciones Posoperatorias/terapia , Aortografía/métodos , Infarto Cerebral/complicaciones
6.
J Vasc Surg ; 79(6): 1326-1338, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38286152

RESUMEN

OBJECTIVE: The aim of this study was to investigate the correlation between post-implantation syndrome (PIS) and long-term prognosis in patients with Stanford type B aortic dissection (TBAD) undergoing thoracic endovascular aortic repair (TEVAR). METHODS: This retrospective study included 547 consecutive patients diagnosed with TBAD who underwent TEVAR at our institution between January 2014 and December 2019. Patients were categorized into two groups: the PIS group (patients with post-TEVAR PIS) and the non-PIS group (patients without post-TEVAR PIS). In-hospital and follow-up data were analyzed. RESULTS: The incidence of PIS was 28.9% (158/547 patients). No baseline differences were observed between the PIS (n = 158) and the non-PIS (n = 389) groups. The proportion of emergency surgery in the PIS group was higher than that in the non-PIS group (44.9% vs 26.0%; P < .001), the operation time was longer (median, 65.0; interquartile range [IQR], 56.0-75.0 minutes vs 56.0; IQR, 45.0-66.0 minutes; P < .001), the volume of contrast medium used (median, 65.0; IQR, 56.0-75.0 mL vs 56.0; IQR, 45.0-66.0 mL; P < .001), and the average number of trunk stents (1.85 ± 0.4 vs 1.34 ± 0.5 pieces; P < .001) and branch stents (0.7 ± 0.7 vs 0.2 ± 0.5 pieces; P < .001) used were more in the PIS group than in the non-PIS group. The incidence of supra-aortic branch procedures was higher in the PIS group than in the non-PIS group. There was no significant difference in device-related complications (DRCs) or 30-day mortality between the two groups (2.5% vs 4.4%; P = .442 and 1.3% vs 1.3%; P = .688, respectively). Univariate and multivariable logistic regression analysis showed that emergency surgery, number of trunk stents >1, operation time >58.5 minutes, and contrast medium volume >75 mL were risk factors for PIS, and the odds ratios of emergency operation, number of trunk stents >1 piece, operation time >58.5 minutes, and contrast medium volume >75 mL were 2.526 (95% confidence interval [CI], 1.530-4.173), 4.651 (95% CI, 2.838-7.624), 3.577 (95% CI, 2.201-5.815), and 7.356 (95% CI, 4.111-13.160), respectively. Follow-up was completed in 98.5% (532/540) of the patients, with a median follow-up of 67 months (IQR, 50-86 months). There was no significant difference in survival between the PIS and non-PIS groups (12.4% vs 10.3%; P = .476) during follow-up. The incidences of DRCs (7.8% vs 11.6%; P = .200) and aortic false lumen thrombosis (75.8% vs 79.2%; P = .399) were comparable between the PIS and non-PIS groups. Univariate logistic regression analysis showed that PIS had no effect on long-term follow-up mortality, DRCs, entry flow, or aortic false lumen thrombosis rate. CONCLUSIONS: PIS is relatively common after TEVAR and emergency surgery; number of trunk stents >1, operation time >58.5 minutes, and contrast medium volume >75 mL are of high predictive value for the assessment of PIS after TEVAR. However, PIS had little effect on early and late postoperative mortality or DRCs.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Complicaciones Posoperatorias , Humanos , Estudios Retrospectivos , Disección Aórtica/cirugía , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Procedimientos Endovasculares/instrumentación , Femenino , Masculino , Persona de Mediana Edad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Implantación de Prótesis Vascular/instrumentación , Factores de Riesgo , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/mortalidad , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Factores de Tiempo , Anciano , Resultado del Tratamiento , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Incidencia , Medición de Riesgo , Síndrome , Stents
7.
J Vasc Surg ; 78(1): 61-69.e4, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36921645

RESUMEN

OBJECTIVE: The aim of this study was to evaluate safety and efficacy of thoracic endovascular aortic repair (TEVAR) for acute Stanford type B aortic dissection (TBAD) with retrograde type A intramural hematoma (TAIMH). METHODS: Patients with acute TBAD with retrograde TAIMH treated with TEVAR between January 1, 2014, to March 31, 2022, were retrospectively reviewed. Aortic diameter and distance were measured using the 3D Slicer image computing platform. Patients' characteristics, procedural, in-hospital and follow-up data, and aortic remodeling were analyzed. RESULTS: Fifty-two patients (average age, 52.6 years; 42 males [80.8%]) were included. The median interval from symptom onset to TEVAR was 11 days (interquartile range, 7.0-16.8 days). The maximal diameter of the ascending aorta (AA) was <50 mm, and the hematoma thickness in the AA was ≤10 mm in all patients. Both the in-hospital and 30-day mortality rates were 0%. The 30-day complication rate was 11.5%. The overall cumulative survival rates were 100% at 1 year, 97.1% at 3 years, and 92.6% at 5 years. Four of 52 patients (7.7%) developed retrograde type A aortic dissection at 10 days to 4 months postoperatively, and one of 52 patients (1.9%) developed an isolated AA dissection 4 months postoperatively; these five patients were treated and alive at late follow-up in March 2022. The rates of cumulative freedom from thoracic aortic re-intervention were 93.7% at 1 year and 90.7% at 5 years. Positive AA remodeling was observed in 92.3% (48/52) of patients during follow-up. The maximal diameter of AA (mean ± standard error of mean) at admission was 42.7 ± 0.8 mm, which decreased to 39.5 ± 0.9 mm at last follow-up. The maximal AA hematoma thickness at admission was 7.6 ± 0.3 mm, which reduced to 2.2 ± 0.9 mm at last follow-up. CONCLUSIONS: For selected patients of acute Stanford TBAD with retrograde TAIMH, endovascular repair may be a safe, effective, and durable alternative treatment, if the maximum diameter of the AA is <50 mm and the intramural hematoma thickness in the AA is ≤10 mm.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Persona de Mediana Edad , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Implantación de Prótesis Vascular/efectos adversos , Estudios Retrospectivos , Procedimientos Endovasculares/efectos adversos , Resultado del Tratamiento , Factores de Tiempo , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Hematoma/diagnóstico por imagen , Hematoma/etiología , Hematoma/cirugía
8.
Exp Anim ; 72(2): 253-261, 2023 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-36464272

RESUMEN

A reproducible canine aortic dissection (AD) model would be useful for evaluating the performance of novel endovascular treatment devices. Therefore, we attempted to create a reproducible canine model of Stanford type B AD (TBAB) by a surgical method. Computed tomography angiography was performed 2 h after the procedure to determine if a false lumen was present, and follow-up imaging was performed 10 d after the procedure using digital subtraction angiography, intravascular ultrasound (IVUS), and color Doppler flow imaging (CDFI) to confirm stable persistence of the false lumen. The success rate of model construction was 88.8% (16/18). All surviving dogs had distal re-entries (16/16). The number of re-entries in the dogs was 1.50 ± 0.52, and the mean length of the false lumen was 175.37 ± 16.98 mm. IVUS showed the area of the false lumen at the narrowest part of the arterial lumen was 84.88 ± 1.27%. The CDFI showed that the peak systolic velocity in the false lumen (10.89 ± 0.74 cm/s) was significantly slower than that in the true lumen (25.31 ± 1.72 cm/s; P<0.001). Moreover, the direction of blood flow in the true lumen was consistent, whereas that in the false lumen was disordered. We optimized the traditional surgical method to construct a canine model of TBAD to improve the success rate of model construction, and designed a novel device to lengthen the false lumen. The proposed model has wide implications in evaluating the performance of novel endovascular treatment devices and studying the AD-related hemodynamics.


Asunto(s)
Disección Aórtica , Implantación de Prótesis Vascular , Perros , Animales , Stents , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Tomografía Computarizada por Rayos X , Hemodinámica , Resultado del Tratamiento
9.
International Journal of Surgery ; (12): 175-179, 2023.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-989427

RESUMEN

Objective:To compare the curative effect and cost of domestic and imported covered stents in the treatment of non-complex Stanford type B aortic dissection.Methods:A retrospective case-control study was used to analyze the clinical data of 93 patients with non-complex Stanford B aortic dissection who underwent thoracic endovascular aortic repair (TEVAR) in Taizhou Second People's Hospital from September 2016 to September 2021.Ninty-three patients were divided into two groups according to the use of different covered stents during the operation, of which 47 patients were treated with domestic covered stents (observation group) and 46 patients were treated with imported covered stents (control group). Overall response rate, rate of complication, treatment cost and cost-effectiveness ratio of the two groups were compared and sensitivity analysis was performed in the two groups.The measurement datas conforming to the normal distribution were expressed as mean ± standard deviation( ± s), and the inter-group comparison was conducted by t test.The comparison of counting datas between groups was conducted by Chi-square test or Fisher exact probability method. Results:The overall response rate of the observation group and the control group were 93.62% and 97.83%, with no significant difference ( P>0.05); The incidence of complications was 6.38% and 2.17%, with no significant difference ( P>0.05). The cost of covered stent [(62 155.49±10 231.08) yuan] and the total cost of treatment [(95 063.66±20 042.34) yuan] in the observation group were lower than those in the control group [(93 825.37±16 577.04) yuan and (126 035.89±26 186.18) yuan]( P<0.05). There was no significant difference in other direct costs between the observation group [(32 908.17±9 811.26) yuan] and the control group [(32 210.52±9 609.14) yuan] ( P >0.05). The cost-effectiveness ratio of the observation group and the control group were 1 015.42 and 1 288.31, and the incremental cost-effectiveness ratio of the control group was 7 356.82. After the cost-effectiveness sensitivity analysis and adjusting the cost of the covered stent to decrease by 10% of the two groups, the cost-effectiveness ratio of the observation group and the control group were 949.03 and 1 192.41, and the incremental cost-effectiveness ratio of control group was 6 604.61. Conclusions:Both domestic and imported covered stents are effective in the treatment of non-complex Stanford type B aortic dissection with fewer complications. Compared with the imported covered stent, the domestic covered stent has lower treatment cost and more advantages of cost-effectiveness, which is more in line with diagnosis related groups reform.

10.
Ann Vasc Dis ; 15(2): 142-145, 2022 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-35860818

RESUMEN

Alport syndrome is often characterized by renal dysfunction and hearing loss due to abnormalities in type IV collagen production. In this study, we report a rare case of recurrent aortic dissections that developed in a young patient with Alport syndrome over a short period. We discuss the associations between Alport syndrome and aortic dissection with a literature review and emphasize the need for regular follow-up of patients with Alport syndrome for early detection of aortic disease.

11.
J Vasc Surg ; 76(4): 1099-1108.e3, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35390485

RESUMEN

OBJECTIVE: Best medical therapy (BMT) should be recommended for treating uncomplicated Stanford type B aortic dissection (uSTBAD), whereas thoracic aortic endovascular repair (TEVAR) has been controversial for uSTBAD. METHODS: In this paper, a meta-analysis was conducted on all available randomized controlled trials and observational studies that evaluated the relative benefits and harms of TEVAR and BMT for the management of patients suffering from uSTBAD. Primary endpoints consisted of early adverse events, long-term adverse events, and aortic remodeling. In addition, risk differences (RDs) or odds ratios (ORs) with 95% confidence intervals (CIs) were estimated. The random-effects model or the fixed-effects model was used in accordance with the 50% heterogeneity threshold. RESULTS: Seven observational studies and two randomized controlled studies from 11 articles that contained 15,066 patients with uSTBAD (1518 TEVARs) met the inclusion criteria. For early outcomes, no significant differences were found between the TEVAR group and the BMT group in aortic rupture, retrograde dissection, paraplegia/paraparesis, reintervention, aorta-related death, and all-cause death. In the long run, the TEVAR group was found to have a significantly lower incidence of adverse events, which included aortic rupture (OR, 0.26; 95% CI, 0.16-0.42; P < .05; heterogeneity: P = .90, I2 = 0%), reintervention (OR, 0.45; 95% CI, 0.26-0.75; P < .05; heterogeneity: P = .17, I2 = 41%), aorta-related death (OR, 0.27; 95% CI, 0.18-0.42; P < .05; heterogeneity: P = .61, I2 = 0%), and all-cause death (OR, 0.52; 95% CI, 0.42-0.66; P < .05; heterogeneity: P = .05, I2 = 53%) as compared with the BMT group. Moreover, in compared with BMT, TEVAR was found to significantly contribute to the complete thrombosis of thoracic false lumen (OR, 55.34; 95% CI, 34.32-89.21; P < .05; heterogeneity: P = .97, I2 = 0%), and aortic regression (true lumen expansion and false lumen shrinkage). CONCLUSIONS: Although early endovascular repair of uSTBAD does not outperform BMT, its implementation is found to be necessary to facilitate the long-term prognosis. Accordingly, if early TEVAR is to be deferred, close follow-up is critical to allow for timely reintervention.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Rotura de la Aorta , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/etiología , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/cirugía , Rotura de la Aorta/etiología , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Estudios Observacionales como Asunto , Estudios Retrospectivos , Resultado del Tratamiento
12.
Interact Cardiovasc Thorac Surg ; 34(6): 1132-1140, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35147677

RESUMEN

OBJECTIVES: In uncomplicated type B aortic dissection, a large false lumen (FL) is reportedly a risk factor for late aortic events. However, it is unclear how the relationship between the false and true lumen (TL) diameters affects the dissected aorta. This study aimed to evaluate the impact on clinical outcomes of the FL being larger than the TL. METHODS: We retrospectively reviewed 111 consecutive patients with uncomplicated acute type B aortic dissection between 2004 and 2018. We divided the patients into group A (FL > TL; n = 51) and group B (FL ≤ TL; n = 60), and compared the outcomes. The endpoints were aortic events, including surgery for aortic dissection and indication for surgery, and mortality. RESULTS: The 5-year incidence rates of aortic events were 68.4% in Group A and 33.6% in Group B (P = 0.002). The 5-year all-cause mortality rates were 5.3% in Group A and 21.9% in Group B (P = 0.003). The multivariable analyses revealed that FL > TL was an independent factor associated with aortic events (adjusted hazard ratio 2.482, 95% confidence interval 1.467-4.198, P < 0.001), but had low mortality (adjusted hazard ratio 0.209, 95% confidence interval 0.073-0.597, P = 0.003). CONCLUSIONS: Patients with uncomplicated type B aortic dissection with FL > TL at admission are at increased risk of aortic events but improve mortality compared to patients with FL ≤ TL. CLINICAL TRIAL REGISTRATION: UMIN000036997.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
13.
Front Cardiovasc Med ; 9: 1099055, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36698955

RESUMEN

Background: This study aimed to identify the risk factors for in-hospital mortality in patients with Stanford type B aortic dissection (TBAD) and develop and validate a prognostic dynamic nomogram for in-hospital mortality in these patients. Methods: This retrospective study involved patients with TBAD treated from April 2002 to December 2020 at the General Hospital of Northern Theater Command. The patients with TBAD were divided into survival and non-survival groups. The data were analyzed by univariate and multivariate logistic regression analyses. To identify independent risk factors for in-hospital mortality, multivariate logistic regression analysis, least absolute shrinkage, and selection operator regression were used. A prediction model was constructed using a nomogram based on these factors and validated using the original data set. To assess its discriminative ability, the area under the receiver operating characteristic curve (AUC) was calculated, and the calibration ability was tested using a calibration curve and the Hosmer-Lemeshow test. Clinical utility was evaluated using decision curve analysis (DCA) and clinical impact curves (CIC). Results: Of the 978 included patients, 52 (5.3%) died in hospital. The following variables helped predict in-hospital mortality: pleural effusion, systolic blood pressure ≥160 mmHg, heart rate >100 bpm, anemia, ischemic cerebrovascular disease, abnormal cTnT level, and estimated glomerular filtration rate <60 ml/min. The prediction model demonstrated good discrimination [AUC = 0.894; 95% confidence interval (CI), 0.850-0.938]. The predicted probabilities of in-hospital death corresponded well to the actual prevalence rate [calibration curve: via 1,000 bootstrap resamples, a bootstrap-corrected Harrell's concordance index of 0.905 (95% CI, 0.865-0.945), and the Hosmer-Lemeshow test (χ2 = 8.3334, P = 0.4016)]. DCA indicated that when the risk threshold was set between 0.04 and 0.88, the predictive model could achieve larger clinical net benefits than "no intervention" or "intervention for all" options. Moreover, CIC showed good predictive ability and clinical utility for the model. Conclusion: We developed and validated prediction nomograms, including a simple bed nomogram and online dynamic nomogram, that could be used to identify patients with TBAD at higher risk of in-hospital mortality, thereby better enabling clinicians to provide individualized patient management and timely and effective interventions.

14.
Journal of Medical Biomechanics ; (6): E323-E328, 2022.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-961731

RESUMEN

Objective Based on hemodynamic analysis, to investigate the cause of distal re-entry tear in Stanford type B aortic dissection after thoracic endovascular aortic repair (TEVAR).Methods A patient with type B aortic dissection was reexamined regularly with computed tomography angiography (CTA) at 1st month, 6th month, 12th month and 24th month after TEVAR. Based on the CTA images in each period, three-dimensional (3D) aorta models were reconstructed to perform morphological analysis and hemodynamic simulation.Results Compared with the diameter at 1st month after TEVAR, the diameter of true lumen at 12 months after TEVAR increased by 1.8 times and the global distortion of aorta increased by 16.67%. At postoperative 1st, 6th and 12th month, the maximum blood velocities at the new entry tear in systole were 69.6%, 33.7% and 92.1% higher than the average ones at distal landing zone, and the maximum wall shear stresses (WSSs) were 2.52, 2.32 and 3.52 times of the average WSSs respectively. In addition, the maximum time-averaged WSS (TAWSS) at 1st, 6th and 12th month after TEVAR were 1.88, 2.53 and 3.62 times of the mean TAWSS respectively.ConclusionsThe morphology of the aorta remodeled after TEVAR, and a sudden change in the diameter of true lumen occurred at distal anchoring zone and continued to increase. As a result, the blood flow velocity in this area accelerated, and the intima was continuously exposed to high WSS, leading to the redissection.

15.
Front Cardiovasc Med ; 8: 752763, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34869658

RESUMEN

Background: Obstructive sleep apnoea (OSA) is highly prevalent in patients with Stanford type B aortic dissection (TBAD). Few studies have evaluated the effects of OSA on vascular changes in TBAD patients. This study aimed to explore the effect of OSA on aortic morphological changes in TBAD patients and its relation to late aortic events (LAEs). Methods: This case-control study included 143 TBAD patients. The diameters of different parts of the aorta were measured based on computed tomography angiography (CTA). According to the apnoea-hypopnoea index (AHI), OSA was classified as mild (5 ≤ AHI ≤ 15), moderate (15 < AHI ≤ 30), or severe (AHI > 30). The false lumen (FL) status was evaluated and classified as partially thrombosed, patent, or completely thrombosed. Results: The OSA prevalence in TBAD patients was 64.3%, and image differences related to LAEs between TBAD patients with and without OSA included the maximum aortic diameter at onset (37.3 ± 3.9 vs. 40.3 ± 4.5 mm, p < 0.001), the FL diameter of the proximal descending thoracic aorta (16.0 ± 6.8 vs. 20.3 ± 4.7 mm, p < 0.001), and the proportion of the FL that was partially thrombosed (39.2 vs. 64.1%, p = 0.004). Additionally, in the multivariable analysis of patients with OSA, the risks of an aortic diameter ≥40 mm, a proximal descending aorta FL ≥ 22 mm and a partially thrombosed FL were 4.611 (95% CI: 1.796-11.838, p = 0.001), 2.544 (95% CI: 1.050-6.165, p = 0.039), and 2.565 (95% CI: 1.167-5.637, p = 0.019), respectively, after adjustment for confounding factors. Trend tests showed that the risks of an aortic diameter ≥40 mm and a partially thrombosed FL increased with increasing OSA severity. Conclusions: TBAD patients with moderate to severe OSA have aortic dilatation in different parts of the aorta. OSA is an independent risk factor for multiple imaging signs related to LAEs, suggesting that OSA is an important factor affecting the prognosis of TBAD patients.

16.
J Clin Anesth ; 75: 110498, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34488061

RESUMEN

STUDY OBJECTIVE: To determine the effect of dexmedetomidine on acute kidney injury (AKI) following endovascular aortic repair (EVAR) for Stanford type B aortic dissection (TBAD). DESIGN: Randomized, double-blind, placebo-controlled, pilot study. SETTING: University Hospital. PATIENTS: 102 TBAD patients undergoing EVAR procedures were enrolled. Patients with dissection involving aortic arch or renal artery were excluded. INTERVENTIONS: Patients were randomly assigned, in a 1:1 ratio, to a dexmedetomidine group (intravenous dexmedetomidine 0.4 µg/kg/h immediately after anesthesia induction and 0.1 µg/kg/h after extubation, which was maintained until 24 h) or a normal saline control group. MEASUREMENTS: The primary outcome was the incidence of AKI within the first two days after surgery, based on the Acute Kidney Injury Network (AKIN) criteria. The secondary outcomes included serum cystatin C and estimated glomerular filtration rate on postoperative days 1, 2, and 7, and in-hospital need for renal replacement therapy (RRT). Long-term outcomes included RRT and all-cause mortality. MAIN RESULTS: Ninety-eight patients completed the study (dexmedetomidine, n = 48; control, n = 50). AKIN stage 1 AKI occurred in 3/48 (6.3%) patients receiving dexmedetomidine, compared with 11/50 (22%) patients receiving normal saline (odds ratio = 0.24, 95% CI: 0.07 to 0.89, P = 0.041). This difference remained significant after adjusting for baseline covariates (adjusted odds ratio = 0.21, 95% CI: 0.05 to 0.84; P = 0.028). Dexmedetomidine led to a lower serum cystatin C on postoperative day 1 (median [IQR] mg/L: 1.31 [1.02-1.72] vs. 1.58 [1.28-1.96]). There were no between-group differences in other secondary or long-term outcomes. During the follow-up (median = 28.4 months), 1 patient in the dexmedetomidine group and 3 patients in the control group required RRT. CONCLUSIONS: Dexmedetomidine reduced the incidence of AKI in TBAD patients after EVAR procedures. The long-term benefits of dexmedetomidine in this patient population warrant further investigation. TRIAL REGISTRATION: ChiCTR-IPR-15006372.


Asunto(s)
Lesión Renal Aguda , Disección Aórtica , Dexmedetomidina , Procedimientos Endovasculares , Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/epidemiología , Disección Aórtica/cirugía , Procedimientos Endovasculares/efectos adversos , Humanos , Proyectos Piloto , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
17.
J Int Med Res ; 49(3): 300060520957933, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33787369

RESUMEN

OBJECTIVES: To compare the efficacy and prognosis of one-stop hybrid surgery using the elephant trunk procedure for treatment of complex Stanford type B aortic dissection. METHODS: We retrospectively analyzed patients who underwent surgical treatment from January 2014 to July 2019. The patients were divided into those who underwent the elephant trunk procedure (n = 10) and those who underwent one-stop hybrid surgery (n = 10). The cardiopulmonary bypass time, mechanical ventilation time, length of hospital stay, and red blood cell usage were compared between the two groups. All patients' 3-month postoperative aortic computed tomography angiography (CTA) findings were also reviewed. RESULTS: The cardiopulmonary bypass time, mechanical ventilation time, and length of hospital stay were significantly shorter and red blood cell usage was significantly lower in the one-stop hybridization group. The aortic cross-clamp time was not significantly different between the two groups. Aortic CTA review after hybrid surgery showed that the true lumen of the descending aorta was almost completely restored at 3 months. CONCLUSION: One-stop hybrid surgery effectively alleviated the occlusion of the aortic dissection, prevented the need for additional surgery, and expanded the indications for covered-stent endovascular repair.


Asunto(s)
Disección Aórtica , Implantación de Prótesis Vascular , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta Torácica/cirugía , Humanos , Estudios Retrospectivos , Stents , Resultado del Tratamiento
18.
Chinese Critical Care Medicine ; (12): 962-966, 2021.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-909435

RESUMEN

Objective:To investigate the clinical characteristics as well as short-term and long-term prognostic factors of patients with Stanford type B aortic dissection (TBAD) with hypertension.Methods:Patients with TBAD who received thoracic endovascular aortic repair (TEVAR) admitted to Xiangyang Central Hospital from January 2014 to December 2018 were enrolled. The baseline data of patients admitted to the hospital were collected through the case management system, including gender, age, underlying diseases (hypertension, diabetes, coronary heart disease), smoking history, drinking history, duration of pain, vital signs at admission [heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP)], laboratory results [white blood cell count (WBC), platelet count (PLT), neutrophil/lymphocyte ratio (NLR), serum creatinine (SCr), C-reactive protein (CRP), D-dimer, ascending aorta diameter], etc. The clinical characteristics of TBAD patients with hypertension were analyzed. Logistic regression model and Cox proportional risk model were used to analyze the impact of hypertension on the short-term and long-term all-cause deaths after TEVAR in TBAD patients.Results:Among 227 TBAD patients, 160 cases (70.5%) were complicated with hypertension, while 67 cases (29.5%) were not. The average age, the proportion of diabetes and coronary heart disease, and the level of SBP, DBP and SCr at admission of TBAD patients with hypertension were higher than those of TBAD without hypertension [age (years old): 53.1±11.9 vs. 42.8±14.1, combined with diabetes: 8.8% vs. 1.5%, combined with coronary heart disease: 6.3% vs. 0%, SBP (mmHg, 1 mmHg = 0.133 kPa): 147.9±18.1 vs. 136.9±15.2, DBP (mmHg): 93.9±11.9 vs. 89.1±13.8, SCr (μmol/L): 97.8±25.4 vs. 89.8±23.6, all P < 0.05]. The short-term mortality of TBAD with hypertension group was significantly higher than that of TBAD without hypertension group [6.3% (10/160) vs. 0% (0/67), χ2 = 4.386, P = 0.036]. 227 patients with TBAD were followed up for 3-66 months, with a median follow-up time of 25 months. There was no significant difference in long-term mortality between TBAD patients with and without hypertensive during discharge follow-up [13.1% (21/160) vs. 9.0% (6/67), χ2 = 0.784, P = 0.376]. Further multivariate Logistic regression analysis and Cox regression analysis did not indicate that hypertension was an independent risk factor for short-term and long-term death in TBAD patients [odds ratio ( OR) and 95% confidence interval (95% CI) were 13.477 (0.541-330.215), 1.012 (0.990-1.035), both P > 0.05]. Age and HR were independent risk factors for the short-term mortality of TBAD patients [ OR and 95% CI were 15.287 (1.051-226.415), 0.026 (0.002-0.840), both P < 0.05]. Age, PLT and D-dimer were independent risk factors for the long-term mortality of TBAD patients [ OR and 95% CI were 1.808 (1.205-2.711), 0.555 (0.333-0.924), 1.482 (1.035-2.122), respectively, all P < 0.05]. Conclusions:The TBAD patients with hypertension have older age, high rates of diabetes or coronary heart disease. However, hypertension is not an independent risk factor for short-term and long-term mortality in TBAD patients.

19.
J Cardiothorac Surg ; 15(1): 282, 2020 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-32993726

RESUMEN

BACKGROUND: Open stented elephant trunk (SET) or SET with left subclavian artery (LSCA) to left common carotid artery (LCCA) bypass is proven to a potentially alternative treatment for complicated Stanford type B aortic dissection (TBAD). In the current study, we reported our experience with ten consecutive TBAD patients who underwent open SET. METHODS: Patients with complicated TBAD underwent open SET from May 2016 to November 2018 in our institution were included. Patients' clinical data were obtained from the electronic medical record system, and long-term clinical outcomes were collected by telephone interviews or outpatient interviews. RESULTS: A total of ten patients with nine males and one female were included, and the average age was 47.3 (31-65) years. Increased D-dimer and fibrinogen degradation products were observed in all patients at admission, and two patients had renal insufficiency. The average postoperative mechanical ventilation time, length of stay in intensive care unit, and postoperative hospital length of stay were 46.9 (6.7-151.2) hours, 7.7 (4-17) days, and 15.7 (10-26) days. No postoperative death occurred. Acute kidney injury and other complications were observed, and they were recovered well when discharge. In long-term follow-up, computed tomography angiography indicated that aortas were completely well remodeled, and blood supply of the brachiocephalic trunks was normal without anastomotic complications. All patients lived well. CONCLUSION: SET or SET with subclavian artery correction shows satisfactory clinical outcomes, and it could be considered as an alternative treatment. Well-designed, large-scale studies with long-term follow-up are still needed.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Stents , Arteria Subclavia/cirugía , Adulto , Anciano , Disección Aórtica/diagnóstico por imagen , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Implantación de Prótesis Vascular/métodos , Angiografía por Tomografía Computarizada , Femenino , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Respiración Artificial , Arteria Subclavia/diagnóstico por imagen
20.
J Int Med Res ; 48(8): 300060520945506, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32776820

RESUMEN

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) is considered the mini-invasive treatment of choice for patients with Stanford type B aortic dissection (TBAD). This study aimed to investigate the clinical outcomes and quality of life (QoL) in patients with acute and subacute TBAD after TEVAR. METHODS: From January 2014 until July 2016, 22 acute patients (Group A) and 18 subacute patients received TEVAR (Group B), and 13 patients were managed non-operatively (Group C). The Medical Outcomes Study Short Form-36 was used to assess QoL preoperatively and after TEVAR. Operative techniques and complications were retrospectively analyzed. RESULTS: The role emotion, vitality, and mental health domains scored well preoperatively. Except for role emotion, vitality, and mental health, the remaining domains significantly improved after TEVAR. There was no significant difference in QoL metrics between Groups A and B. In Group C, bodily pain and social functioning domains were improved, and role emotion was decreased, with no improvement in the remaining domains. The 3-year survival rates were 95.5%, 100%, and 85.7% for Groups A, B, and C, respectively. CONCLUSIONS: TEVAR may be safe and effective in patients with acute and subacute TBAD with similar and favorable clinical and QoL metrics.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Humanos , Complicaciones Posoperatorias/cirugía , Calidad de Vida , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA