Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Heliyon ; 10(11): e32576, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38961964

RESUMEN

Purpose: To evaluate the efficacy of the endoscopic lumbar interbody fusion technique across different types of lumbar spondylolisthesis, specifically Grade I and Grade II, and suggest technical optimizations based on therapeutic outcomes, complications, and patient satisfaction for both grades. Methods: We analyzed data from 57 L4 to 5 spondylolisthesis patients, all categorized as either Grade I or Grade II, comprising 31 males and 26 females. Of these, 36 were diagnosed with Grade I and 21 with Grade II. All subjects underwent the endoscopic lumbar interbody fusion procedure. Primary evaluation metrics included pre and post-operative Vasual Analogue Scale(VAS) pain scores, Osewewtry Disability Index(ODI) functional scores, surgical duration, intraoperative blood loss, degree of spondylolisthesis correction, complications, and patient satisfaction levels. Results: At a minimum of 6 months post-operation, the VAS score for the Grade I cohort reduced from an initial 7.30 ± 0.69 to 2.97 ± 0.47, while the Grade II cohort saw a decrease from 7.53 ± 0.56 to 3.37 ± 0.62 (P = 0.0194). The ODI score in the Grade I group declined from 66.88 ± 5.15 % pre-operation to 29.88 ± 6.36 % post-operation, and in the Grade II group, it decreased from 69.33 ± 5.27 % to 34.66 ± 6.01 % (P = 0.0092). The average surgical duration for the Grade I group stood at 155.72 ± 17.75 min, compared to 180.38 ± 14.72 min for the Grade II group (P < 0.001). The mean intraoperative blood loss for the Grade I group was 144.58 ± 28.61 ml, whereas the Grade II group registered 188.23 ± 9.41 ml (P < 0.001). Post-surgery, 83 % of the Grade I patients achieved a correction degree exceeding 80 %, and 61 % of the Grade II patients surpassed 50 % (P = 0.0055). Complication rates were recorded at 8 % for Grade I and 16 % for Grade II. Patient satisfaction reached 94 % in the Grade I cohort and 90 % in the Grade II cohort. Conclusion: Endoscopic lumbar interbody fusion showcases promising therapeutic outcomes for both Grade I and Grade II lumbar spondylolisthesis. However, surgeries for Grade II spondylolisthesis tend to be lengthier, more challenging, involve greater blood loss, and have a heightened complication risk. Tailored technical adjustments and enhancements are essential for addressing the distinct spondylolisthesis types.

4.
Acta Neurochir (Wien) ; 166(1): 246, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38831229

RESUMEN

BACKGROUND: Endoscopic spine surgery has recently grown in popularity due to the potential benefits of reduced pain and faster recovery time as compared to open surgery. Biportal spinal endoscopy has been successfully applied to lumbar disc herniations and lumbar spinal stenosis. Obesity is associated with increased risk of complications in spine surgery. Few prior studies have investigated the impact of obesity and associated medical comorbidities with biportal spinal endoscopy. METHODS: This study was a prospectively collected, retrospectively analyzed comparative cohort design. Patients were divided into cohorts of normal body weight (Bone Mass Index (BMI)18.0-24.9), overweight (BMI 25.0-29.9) and obese (BMI > 30.0) as defined by the World Health Organization (WHO). Patients underwent biportal spinal endoscopy by a single surgeon at a single institution for treatment of lumbar disc herniations and lumbar spinal stenosis. Demographic data, surgical complications, and patient-reported outcomes were analyzed. Statistics were calculated amongst treatment groups using analysis of variance and chi square where appropriate. Statistical significance was determined as p < 0.05. RESULTS: Eighty-four patients were followed. 26 (30.1%) were normal BMI, 35 (41.7%) were overweight and 23 (27.4%) were obese. Patients with increasing BMI had correspondingly greater American Society of Anesthesiologist (ASA) scores. There were no significant differences in VAS Back, VAS Leg, and ODI scores, or postoperative complications among the cohorts. There were no cases of surgical site infections in the cohort. All cohorts demonstrated significant improvement up to 1 year postoperatively. CONCLUSIONS: This study demonstrates that obesity is not a risk factor for increased perioperative complications with biportal spinal endoscopy and has similar clinical outcomes and safety profile as compared to patients with normal BMI. Biportal spinal endoscopy is a promising alternative to traditional techniques to treat common lumbar pathology.


Asunto(s)
Índice de Masa Corporal , Descompresión Quirúrgica , Endoscopía , Vértebras Lumbares , Obesidad , Estenosis Espinal , Humanos , Obesidad/cirugía , Obesidad/complicaciones , Masculino , Femenino , Persona de Mediana Edad , Descompresión Quirúrgica/métodos , Descompresión Quirúrgica/efectos adversos , Vértebras Lumbares/cirugía , Estenosis Espinal/cirugía , Anciano , Resultado del Tratamiento , Adulto , Estudios Retrospectivos , Endoscopía/métodos , Endoscopía/efectos adversos , Desplazamiento del Disco Intervertebral/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios de Cohortes
5.
Eur Spine J ; 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38847817

RESUMEN

BACKGROUND: Thoracic ossification of the ligamentum flavum (TOLF), a rare condition more prevalent in East Asia, is managed through open and endoscopic surgical approaches. Determining the superior surgical option remains unclear. This study assesses the safety and clinical outcomes associated with these approaches in TOLF patients. METHODS: Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, we conducted a systematic literature search up to August 5, 2023, across PubMed, Scopus, EMBASE, Web of Science, Cochrane, and ClinicalTrials.gov. We included randomized controlled trials and cohort studies reporting complication rates, mJOA (modified Japanese Orthopedic Association) scores, JOA scores, VAS (Visual Analog Scale) scores, or hospitalization duration for both open and endoscopic surgeries in TOLF patients. RESULTS: We analyzed 37 studies encompassing 1,646 TOLF patients using a random-effects model. Our findings revealed a significant difference in complication rates (overall complication rates: 0.12; 95% CI: 0.07, 0.19; p < 0.01; I2: 69%; quality of evidence: moderate), with lower complication rates in the endoscopy group. However, no significant differences were observed in JOA scores (overall JOA: 8.35; 95% CI: 7.16, 9.54; p = 0.12; I2: 99%; quality of evidence: very low), VAS scores (overall VAS: 1.31; 95% CI: 1.03, 1.59; p = 0.35; I2: 91%; quality of evidence: very low), or hospitalization duration (hospital stay: 10.83 days; 95% CI: 6.86, 14.80; p = 0.35; I2: 91%; quality of evidence: very low) between the open and endoscopic groups. CONCLUSIONS: This meta-analysis reports lower complication rates and improved postoperative mJOA scores for endoscopic surgery in TOLF patients compared to open surgery. It represents the first comprehensive evaluation of clinical outcomes and safety of different surgical approaches for TOLF patients. Further randomized controlled trials are essential to validate these findings.

6.
Am J Transl Res ; 16(5): 1779-1789, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38883385

RESUMEN

OBJECTIVE: To compare the surgical metrics, improvement of functional scores, and clinical efficacy of percutaneous endoscopic transforaminal discectomy (PETD) and percutaneous endoscopic interlaminar discectomy (PEID) and to analyze the independent risk factors affecting the therapeutic efficacy of PETD. METHODS: The clinical data of LDH (lumbar disc herniation) patients who underwent treatment in Shaanxi Provincial Nuclear Industry 215 Hospital from May 2020 to May 2022 were retrospectively collected, including 70 PEID cases and 74 PETD cases. The two groups were compared in terms of surgical indexes, such as operation time and bleeding volume, as well as changes in functional scores, such as preoperative and postoperative Visual Analogue Scale (VAS) scores and Oswestry Disability Index (ODI). The clinical efficacy was evaluated according to the Macnab criteria, and logistic regression analysis was performed to determine the independent influencing factors of the treatment efficacy of PETD. RESULTS: The differences between the two surgical groups were statistically significant in terms of operation time (P<0.001), bleeding (P=0.005), and C-arm X-ray exposure times (P<0.001), and the above indexes were higher in the PETD group; however, there were no statistical differences in terms of improvement in functional scores (P>0.05) and clinical efficacy (P>0.05) between the two groups. BMI≥25 kg/m2 (P=0.001), severe disc degeneration (P=0.003), and operation time ≥60 min (P=0.003), severe disc degeneration (P=0.003), and operation time ≥60 min (P=0.036) were independent risk factors for the outcome of PETD. CONCLUSION: The clinical effectiveness of PEID and PETD in treating LDH is comparable, and each has its own advantages. While PETD is more technically demanding, it does not yield superior results. Obesity, severe disc degeneration, and prolonged surgery are risk factors for the treatment efficacy of PETD.

7.
Indian J Orthop ; 58(5): 587-597, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38694692

RESUMEN

Background: Lumbar disc herniation is a common degenerative lumbar disease with an increasing incidence. Percutaneous endoscopic lumbar discectomy can treat lumbar disc herniation safely and effectively with a minimally invasive procedure. However, the learning curve of this technology is steep, which means that initial learners are often not sufficiently proficient in endoscopic operations, which can easily lead to iatrogenic damage. At present, the application of computer deep learning technology to clinical diagnosis, treatment, and surgical navigation has achieved satisfactory results. Purpose: The objective of our team is to develop a multi-element identification system for the visual field of endoscopic spine surgery using deep learning algorithms and to evaluate the feasibility of this system. Method: We established an image database by collecting surgical videos of 48 patients diagnosed with lumbar disc herniation, which was labeled by two spinal surgeons. We selected 6000 images of the visual field of percutaneous endoscopic spine surgery (including various tissue structures and surgical instruments), divided into the training data, validation data, and test data according to 2:1:2. We developed convolutional neural network models based on instance segmentation-Solov2, CondInst, Mask R-CNN and Yolact, and set the four network model backbone as ResNet101 and ResNet50 respectively. Mean average precision (mAP) and frames per second (FPS) were used to measure the performance of each model for classification, localization and recognition in real time, and AP (average) is used to evaluate how easily an element is detected by neural networks based on computer deep learning. Result: Comprehensively comparing mAP and FSP of each model for bounding box test and segmentation task for the test set of images, we found that Solov2 (ResNet101) (mAP = 73.5%, FPS = 28.9), Mask R-CNN (ResNet101) (mAP = 72.8%, FPS = 28.5) models are the most stable, with higher precision and faster image processing speed. Combining the average precision of the elements in the bounding box test and segmentation tasks in each network, the AP(average) was highest for tool 3 (bbox-0.85, segm-0.89) and lowest for tool 5 (bbox-0.63, segm-0.72) in the instrumentation, whereas in the anatomical tissue elements, the fibrosus annulus (bbox-0.68, segm-0.69) and ligamentum flavum (bbox-0.65, segm-0.62) had higher AP(average),while extra-dural fat (bbox-0.42, segm-0.44) was lowest. Conclusion: Our team has developed a multi-element identification system for the visual field of percutaneous endoscopic spine surgery adapted to the interlaminar and foraminal approaches, which can identify and track anatomical tissue (nerve, ligamentum flavum, nucleus pulposus, etc.) and surgical instruments (endoscopic forceps, an high-speed diamond burr, etc.), which can be used in the future as a virtual educational tool or applied to the intraoperative real-time assistance system for spinal endoscopic operation.

8.
J Orthop Surg Res ; 19(1): 227, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38581052

RESUMEN

OBJECTIVE: Anterior cervical discectomy and fusion (ACDF) is the standard procedure for the treatment of cervical spinal stenosis (CSS), but complications such as adjacent segment degeneration can seriously affect the long-term efficacy. Currently, posterior endoscopic surgery has been increasingly used in the clinical treatment of CSS. The aim of this study was to compare the clinical outcomes of single-segment CSS patients who underwent full endoscopic laminotomy decompression or ACDF. METHODS: 138 CSS patients who met the inclusion criteria from June 2018 to August 2020 were retrospectively analyzed and divided into endoscopic and ACDF groups. The propensity score matching (PSM) method was used to adjust the imbalanced confounding variables between the groups. Then, perioperative data were recorded and clinical outcomes were compared, including functional scores and imaging data. Functional scores included Visual Analog Scale of Arms (A-VAS) and Neck pain (N-VAS), Japanese Orthopedic Association score (JOA), Neck Disability Index (NDI), and imaging data included Disc Height Index (DHI), Cervical range of motion (ROM), and Ratio of grey scale (RVG). RESULTS: After PSM, 84 patients were included in the study and followed for 24-30 months. The endoscopic group was significantly superior to the ACDF group in terms of operative time, intraoperative blood loss, incision length, and hospital stay (P < 0.001). Postoperative N-VAS, A-VAS, JOA, and NDI were significantly improved in both groups compared with the preoperative period (P < 0.001), and the endoscopic group showed better improvement at 7 days postoperatively (P < 0.05). The ROM changes of adjacent segments were significantly larger in the ACDF group at 12 months postoperatively and at the last follow-up (P < 0.05). The RVG of adjacent segments showed a decreasing trend, and the decrease was more marked in the ACDF group at last follow-up (P < 0.05). According to the modified MacNab criteria, the excellent and good rates in the endoscopic group and ACDF group were 90.48% and 88.10%, respectively, with no statistically significant difference (P > 0.05). CONCLUSION: Full endoscopic laminotomy decompression is demonstrated to be an efficacious alternative technique to traditional ACDF for the treatment of single-segment CSS, with the advantages of less trauma, faster recovery, and less impact on cervical spine kinematics and adjacent segmental degeneration.


Asunto(s)
Degeneración del Disco Intervertebral , Disco Intervertebral , Fusión Vertebral , Estenosis Espinal , Humanos , Estudios Retrospectivos , Disco Intervertebral/cirugía , Degeneración del Disco Intervertebral/cirugía , Laminectomía , Estenosis Espinal/diagnóstico por imagen , Estenosis Espinal/cirugía , Estenosis Espinal/complicaciones , Resultado del Tratamiento , Estudios de Seguimiento , Puntaje de Propensión , Fusión Vertebral/métodos , Discectomía/métodos , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Descompresión
9.
J Spine Surg ; 10(1): 68-79, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38567010

RESUMEN

Background: Biportal endoscopic spine surgery is an effective minimally invasive technique for treating common lumbar pathologies. We aim to evaluate the impact of intraoperative tranexamic acid (TXA) use on postoperative blood loss in biportal endoscopic decompression surgery. Methods: Patients undergoing biportal endoscopic lumbar discectomies and decompressions either by same day surgery or overnight stay at a single institution beginning in October 2021 were prospectively enrolled. This study was non-randomized, non-blinded with the first cohort of consecutive patients receiving 1 g of intravenous TXA intra-operatively before closure and the second cohort of consecutive patients receiving no TXA. Exclusion criteria included any revision surgery, any surgery for the diagnosis of spinal instability, infection, tumor, or trauma, any contraindication for TXA. Results: Eighty-four patients were included in the study, with 45 (54%) receiving TXA and 39 (46%) not receiving TXA. Median follow-up was 168 days [interquartile range (IQR), 85-368 days]. There were no differences in patient or surgical characteristics between cohorts. Estimated blood loss (EBL) was similar (P=0.20), while post-operative drain output was significantly lower in the TXA cohort (P=0.0028). Single level discectomies had significantly less drain output as compared to 2 level unilateral laminotomy, bilateral decompression (ULBD) cases (P<0.005). Post-operative complications were similar, with low rates of wound complication (1.2%) and transient postoperative weakness (2.4%, P>0.99 for both). Oswestry disability index (ODI), visual analog scale (VAS) back and VAS leg scores decreased significantly; the absolute decrease in scores did not differ between groups (P=0.71, 0.22, 0.86, respectively). Conclusions: Systemic intraoperative TXA administration is associated with a significant decrease in post-operative blood loss in biportal spinal endoscopy, with no impact on the improvement in patient-reported outcomes (PROs) or rate of post-operative complications. Single level biportal discectomies had significantly less postoperative drainage with TXA and may not need drains postoperatively. Larger, randomized studies are necessary to evaluate the cost-effectiveness of TXA use in biportal spinal endoscopy.

10.
J Pain Res ; 17: 381-392, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38312505

RESUMEN

Objective: To validate whether a residual mass demonstrated on early postoperative MR after percutaneous endoscopic lumbar discectomy (PELD) is indeed an intraoperatively retained annulus fibrosus, and explore the correlation between imaging changes in the residual mass and clinical prognosis of patients. Methods: A prospective study of 118 patients were included. During surgery, a contrast medium, Gadopentetate Dimeglumine, was injected around the ruptured annulus fibrosus. The intensity of the T2 signal, the size of the remaining mass (SR), and the cross-sectional area of the spinal canal (SCSA), VAS, and ODI were assessed at preoperative, 1-h (7-day), 6-month, and 12-month postoperative intervals. Based on VAS at 7 days post-surgery, patients were classified into either a non-remission group (Group A, VAS > 3) or a remission group (Group B, VAS ≤ 3). Results: Six patients who developed recurrent LDH were excluded. A residual mass was detected on MRI 1 h after surgery in 94.6% (106/112). During one year of follow-up, 90.1% (101/112) of the patients displayed fibrous annulus remodeling, although 68.7% (77/112) still exhibited herniation. Significant differences were found in the ODI between Groups A and B one week after surgery (p < 0.001). However, no significant differences were observed in T2 signal intensity, SR, and SCSA at 1-h, 6-month and 12-month post-surgery (p > 0.05) between the two groups. In a multiple linear regression analysis, early postoperative ODI changes were associated with T2 signal (B = -10.22, sig < 0.05), long-term changes were associated with alterations in SR (B = 5.63, sig < 0.05) and SCSA (B = -0.13, sig < 0.05). Conclusion: The residual mass observed in early postoperative MR images after PELD was the retained annulus fibrosus intraoperatively. Short-term changes in clinical symptoms after PELD were linked to T2 signal intensity, while long-term changes were associated with changes in SR and SCSA.

12.
Bioengineering (Basel) ; 11(1)2024 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-38275579

RESUMEN

Spinal endoscopy has evolved significantly since its inception, offering minimally invasive solutions for various spinal pathologies. This study introduces a promising innovation in spinal endoscopy-a single-use digital endoscope designed to overcome the drawbacks of traditional optic endoscopes. Traditional endoscopes, despite their utility, present challenges such as fragility, complex disinfection processes, weight issues, and susceptibility to mechanical malfunctions. The digital endoscope, with its disposable nature, lighter weight, and improved image quality, aims to enhance surgical procedures and patient safety. The digital endoscope system comprises a 30-degree 1000 × 1000 pixel resolution camera sensor with a 4.3 mm working channel, and LED light sources replacing optical fibers. The all-in-one touch screen tablet serves as the host computer, providing portability and simplified operation. Image comparisons between the digital and optic endoscopes revealed advantages in the form of increased field of view, lesser distortion, greater close-range resolution, and enhanced luminance. The single-use digital endoscope demonstrates great potential for revolutionizing spine endoscopic surgeries, offering convenience, safety, and superior imaging capabilities compared to traditional optic endoscopes.

13.
Orthop Surg ; 16(3): 724-732, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38183345

RESUMEN

OBJECTIVE: Spinal endoscopy radiofrequency is a minimally invasive technique for lumbar disc herniation (LDH) and low back pain (LBP). However, recurring LDH/LBP following spinal endoscopy radiofrequency is a significant problem. Paravertebral musculature plays a crucial role in spine stability and motor function, and the purpose of the present study was to identify whether patients' baseline lumbar muscular electrophysiological function could be a predictor of recurring LDH/LBP. METHODS: This was a prospective follow-up and case-control study focusing on elderly patients with LDH who were treated in our department between January 1, 2018, and October 31, 2021. The end of follow-up was recurring LBP, recurring LDH, death, missing to follow-up or 2 years postoperation. The surface electromyography test was performed before the endoscopy C-arm radiofrequency (ECRF) operation to detect the flexion-relaxation ratio (FRR) of the lumbar multifidus (FRRLM ) and the longissimus erector spinae (FRRES ), and the other baseline parameters included the general characteristics, the visual analogue scale, the Japanese Orthopaedic Association score, and the Oswestry Disability Index. Intergroup comparisons were performed by independent t-test and χ2 -test, and further binary logistic regression analysis was performed. RESULTS: Fifty-four patients completed the 2-year follow-up and were retrospectively divided into a recurring LDH/LBP group (Group R) (n = 21) and a no recurring group (Group N) (n = 33) according to their clinical outcomes. FRRLM and FRRES in Group N were much higher than those in Group R (p < 0.001, p = 0.009). Logistic regression analysis showed that only the FRRLM (odds ratio [OR] = 0.123, p = 0.011) and FRRES (OR = 0.115, p = 0.036) were independent factors associated with the ECRF outcome. CONCLUSIONS: Lumbar disc herniation patients' baseline FRRLM and FRRES are independent outcome predictors of recurring LDH/LBP after ECRF. For every unit increase in baseline FRRLM , the risk of recurring LDH/LBP is decreased by 87.7%, and for every unit increase in baseline FRRES , the risk of recurring LDH/LBP is decreased by 88.5%.


Asunto(s)
Desplazamiento del Disco Intervertebral , Dolor de la Región Lumbar , Ablación por Radiofrecuencia , Humanos , Anciano , Dolor de la Región Lumbar/cirugía , Desplazamiento del Disco Intervertebral/complicaciones , Electromiografía , Estudios de Seguimiento , Estudios de Casos y Controles , Estudios Retrospectivos , Estudios Prospectivos , Vértebras Lumbares/cirugía , Resultado del Tratamiento
14.
J Orthop Surg Res ; 19(1): 35, 2024 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-38183142

RESUMEN

BACKGROUND: In this study, we compared the clinical efficacy of endoscope-assisted anterior cervical discectomy and fusion (ACDF) with open ACDF in the treatment of single-segment cervical spondylotic myelopathy. METHODS: A retrospective analysis was performed on 52 patients with single-segment cervical spondylotic myelopathy between June 2021 and February 2022, including 33 males and 19 females, with a mean age of 58.42 ± 9.26) years. Among them, 28 patients were treated with endoscope-assisted ACDF (Group A), including 2 cases of C4/5 segment, 16 cases of C5/6 segment, and 10 cases of C6/7 segment; 24 patients were treated with open ACDF (Group B), including 4 cases of C4/5 segment, 11 cases of C5/6 segment, and 9 cases of C6/7 segment. The operation time, intraoperative blood loss, hospital stay, and complications were recorded and compared between the two groups. The Visual Analogue Scale (VAS) and the Japanese Orthopaedic Association (JOA) score were used for clinical evaluation during the follow-up in the 1st month and 3rd month after surgery, and at the final follow-up. RESULTS: The 52 patients were followed up on average for 13.04 months (12-17 months). The operation time in Group A and Group B was (105.18 + 8.66) minutes and (81.88 + 6.05) minutes, the intraoperative blood loss was (84.29 + 13.45) mL and (112.92 + 17.81) mL, and the hospital stay was (6.75 + 1.29) days and (7.63 + 1.41) days, respectively. The difference between the two groups was statistically significant (P < 0.05). The VAS and JOA scores in the 1st month and the 3rd month after surgery and the last follow-up significantly improved in both groups compared with those before surgery (P < 0.05). The VAS and JOA scores of Group A in the 1st month, 3rd month after surgery, and the last follow-up were better than those in Group B (P < 0.05). The complication rate in Group A was 7% (2/28), which was not significantly different from the 17% (4/24) in Group B (P > 0.05). CONCLUSION: Both endoscope-assisted ACDF and open ACDF can achieve satisfactory clinical efficacy in the treatment of single-segment cervical spondylotic myelopathy. Although the operation time of endoscope-assisted ACDF is prolonged, it has the advantages of clear vision, thorough decompression, less blood loss, and reduced risk of nerve damage, and is worthy of clinical promotion and application.


Asunto(s)
Pérdida de Sangre Quirúrgica , Enfermedades de la Médula Espinal , Femenino , Masculino , Humanos , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Enfermedades de la Médula Espinal/diagnóstico por imagen , Enfermedades de la Médula Espinal/cirugía , Discectomía , Endoscopios
15.
Journal of Clinical Surgery ; (12): 103-105, 2024.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1019304

RESUMEN

The unilateral biportal endoscopic spinal surgery(UBE)technique is an emerging endoscopic technique,mainly used as treatment for lumbar degenerative disease.The procedure is characterized by two working channels,one being endoscopic,the second to be employed as an operating channel.Through the use of such dual-channel-technology,it allows the operating instruments to be unrestricted in size.Therefore,it is a highly efficient surgical technique for minimally invasive spinal surgery(MISS).However,the clinical complications of UBE technology must be taken into consideration.Possible side effects include dural injury,epidural hematoma,occult blood loss,postoperative headache,nerve root injury and insufficient decompression.This article reviews the causes,prevention and management of UBE-related complications.

16.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1021314

RESUMEN

BACKGROUND:Endoscopic treatment of lumbar disc herniation has obvious advantages over traditional open surgery.Endoscopic surgery involves the implantation of a working cannula,which requires only partial bone removal,and there are no studies on the effects of two types of intraoperative foraminoplasty and laminoplasty on the mechanical properties of the local structure of the lumbar spine. OBJECTIVE:To compare the effect of foraminoplasty and laminoplasty on the biomechanical properties of disc and isthmus of the responsible segment. METHODS:The lumbosacral CT images of a healthy male volunteer were taken,and a finite element model M0 of the L3 to sacral vertebrae was established,on which the primary and secondary foraminoplasty models M1 and M2 of the L5/S1 and the laminoplasty model M3 were built.The same load was applied to compare the intervertebral motion range,disc Von Mises stress and equivalent stress characteristics of L5 vertebral isthmus with each model. RESULTS AND CONCLUSION:(1)Compared with M0,M1 and M2 motion range in L5/S1 segment did not change significantly in all directions;M2 overall motion range increased by 8.60%in flexion;M3 increased by 8.23%and 8.26%in L5/S1 right bending and right torsion,and 5.39%and 5.67%in overall motion range in flexion and right bending,with no significant changes in motion range in the rest of working conditions.(2)Compared with M0,M1 showed no significant change in the extremes of Von Mises stress at L5/S1 disc;M2 increased 11.06%,12.50%,18.32%,and 15.48%in flexion,extension,left torsion,and right torsion;M3 increased 12.22%,19.54%,10.05%,and 9.97%in flexion,extension,left torsion,and right torsion,and the rest working conditions and L4/5 disc maximum Von Mises stress did not change significantly.(3)Compared to M0,the maximum Von Mises stress in the left isthmus of L5 of M1 increased by 12.43%in left bending,18.38%,13.29%,13.62%,and 40.00%in the right isthmus in extension,right bending,left torsion,and right torsion.The maximum Von Mises stress in the left isthmus of L5 of M2 increased by 38.87%,42.63%,16.95%,and 19.35%,and that in the right isthmus increased by 12.58%,33.70%,12.92%,and 17.42%in flexion,extension,left bending,and left torsion.The maximum Von Mises stress in the left isthmus of L5 of M3 increased 67.07%,78.14%,32.33%,62.94%,and 89.99%in flexion,extension,left and right bending,and right torsion.(4)The results suggest that foraminoplasty and laminoplasty have a small effect on spinal motion range;there is a mild increase in the extreme values of disc Von Mises stress in the segments operated by interbody laminoplasty and secondary foraminoplasty;there is no significant change in the extreme values of disc Von Mises stress in adjacent segments,and there is a significant increase in the Von Mises stress in the ipsilateral isthmus operated by the interbody laminoplasty model.

17.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1021472

RESUMEN

BACKGROUND:As a leading technique in the treatment of primary stenosis by posterior spinal endoscopy through unilateral approach and bilateral decompression using single channel endoscopy,the long-term efficacy needs to be further observed.There are few reports on the scope of intraoperative resection and few relevant studies on biomechanics and finite element analysis. OBJECTIVE:A three-dimensional finite element model was established to evaluate the effects of bilateral lumbar canal decompression under a one-hole split endoscope on lumbar range of motion and intradiscal pressure,to provide suggestions for clinical operation and theoretical basis for further clinical research. METHODS:A complete L3-L5 vertebral body model was reconstructed by CT images of nine healthy volunteers,which was used as the preoperative model M1.The simulated surgical resection range of L4-L5 was performed,and 1/4,1/3 and 1/2 of bilateral facet joints were removed respectively to obtain models M2,M3 and M4.The range of motion and the maximum Von Mises stress of the four models were compared in the six directions of forward bending,backward extension,left and right bending,and left and right rotation. RESULTS AND CONCLUSION:(1)The L3-L5 finite element model established in this study was effective,and the range of motion was within the range of previous solid studies under six motion states.(2)Compared with the M1 model,the L4-L5 lumbar spine range of motion increased with the increase of resection range in M2 with M3 and M4 models under forward bending,left and right bending and left and right rotation loading,and the difference was significant(P<0.05).Under posterior extension loading,there was no significant difference in lumbar range of motion between M1 and M2(P>0.05),but there was a significant difference of M1,M3 and M4(P<0.05).(3)The range of motion of the L3-L4 lumbar spine had no significant change with the increase of bilateral facet arthrotomy(P>0.05).(4)There was a significant difference in the maximum value of L4-L5 Von Mises between M1 and M2(P<0.05),and there was a significant difference in the maximum value of L4-L5 Von Mises between M1 and M3,M4(P<0.01),and the maximum value of L4-L5 lumbar von Mises increased with the increasing range of bilateral facet joint resection.Resection of more than 1/3 was particularly obvious.(5)The maximum value of Von Mises in the L3-L4 lumbar spine was increased with the increase of the resection range under forward bending,left and right bending and left and right rotation loading and the difference was significant(P<0.05).(6)The results exhibited that the L4-L5 lumbar motion and intervertebral disc pressure increased with the increase of the excision range.Intervertebral disc pressure at L3-L4 increased with the increased extent of excision,but the lumbar range of motion was not significantly affected.In conclusion,the stability of the operative segment may be affected by the increase in the scope of facet joint resection.Although the immediate stability of adjacent segments is not affected,it may accelerate disc degeneration.

18.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1021768

RESUMEN

BACKGROUND:In clinical application,simple interspinous fixation without additional interbody fusion has similar fixation effects to pedicle screw and rod fusion internal fixation,and can effectively reduce the range of motion of the responsible segment and the stress of the articular process.However,after simple placement of the new interspinous fusion fixation device BacFuse,the stress at the root of the spinous process is relatively concentrated,and the spinous fracture is prone to occur.If an intervertebral fusion cage is inserted in conjunction with interspinous fixation,Von Mises stress can theoretically be dispersed to reduce the risk of spinous fracture.However,there are few studies on biomechanics and finite element analysis. OBJECTIVE:To observe the biomechanical stability of interspinous fixation-assisted endoscopic interbody fusion in the treatment of severe lumbar spinal stenosis. METHODS:The normal finite element model M0 of the L4-L5 segment of the lumbar spine was established by Mimics,Geomagic,Solidworks,and ANSYS software based on the lumbar CT images of a 26-year-old adult male volunteer excluding spinal diseases.On the basis of M0,the immediate model M1 after endoscopic decompression combined with interbody fusion,the interspinous fixation device(BacFuse)model M2 after endoscopic decompression,and the interspinous fixation(BacFuse)model M3 after endoscopic-assisted interbody fusion were established.The same stress was applied to the upper surface of the L4 vertebral body in the four groups,and the lower surface of the L5 vertebral body was fixed and supported.The range of motion and the extreme Von Mises stress of the endplate bone and the posterior ligament complex of the vertebral body were analyzed under six working conditions of flexion,extension,left/right bending,and left/right rotation. RESULTS AND CONCLUSION:(1)Compared with model M0,the range of motion value of model M1 increased significantly under six working conditions.Model M2 and model M3 had a significant reduction in range of motion.(2)Compared with model M0,the maximum stress of the vertebral body in model M1 did not change significantly under the six working conditions.The maximum stress at the rear of the M2 vertebral body increased significantly.(3)Compared with model M1,the maximum stress of model M3 did not change significantly under the six working conditions.Compared with model M2,the maximum stress of model M3 decreased significantly.(4)Compared with the model M0,the extreme Von Mises stress of the L4 and L5 endplates of the model M1 was significantly increased.The extreme Von Mises stress in L4 and L5 endplates of models M2 and M3 decreased slightly.Compared with model M1,the Von Mises stress of the bone under the L4 and L5 endplate of models M2 and M3 was significantly reduced.(5)It is concluded that the implantation of BacFuse can effectively reduce the bone stress under the endplate during simple interbody fusion,decrease the risk of cage subsidence,diminish the risk of facet joint fracture on the decompression side,and provide a good stable environment for interbody fusion.The placement of an intervertebral fusion cage can reduce the stress of the root of the spinous process,which is beneficial to decrease the risk of fracture of the root of the spinous process.

19.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1021782

RESUMEN

BACKGROUND:With the rapid development of minimally invasive spinal surgery and enhanced recovery after surgery,endoscopic intervertebral fusion techniques have gradually emerged and been widely used in clinical practice in recent years. OBJECTIVE:To analyze the early clinical efficacy of uniaxial spinal endoscopic intervertebral fusion combined with posterior percutaneous pedicle screw fixation in the treatment of lumbar degenerative diseases. METHODS:135 patients with lumbar degenerative diseases treated by uniaxial spinal endoscopic intervertebral fusion combined with posterior percutaneous pedicle screw fixation in the Suining Central Hospital from October 2020 to December 2021 were enrolled in this study.There were 59 males and 76 females,aged 47-79 years.The lower limb and lumbar pain was evaluated by visual analog scale and lumbar function was assessed by Oswestry disability index before the operation,1 week,1,and 6 months after the operation,and at the end of follow-up.The overall pain recovery of patients was evaluated by the scoring criteria for low back pain surgery of Spine Group of Chinese Orthopedic Association and the lumbar physiological curvature and intervertebral fusion were evaluated on lumbar lateral X-ray preoperatively and at the end of follow-up. RESULTS AND CONCLUSION:(1)The 135 patients were followed up for(17.8±3.0)months after surgery.There was 1 case of endplate injury,1 case of cerebrospinal fluid leakage,1 case of nerve root injury,1 case of intervertebral cage subsidence and displacement,1 case of chronic infection,and 1 case of pedicle screw rupture.The complication rate was 5.2%.(2)The lumbar visual analog scale score and Oswestry disability index significantly decreased in the waist and lower limbs at various time points postoperatively compared with those preoperatively in 135 patients(P<0.05).The scoring criteria for low back pain surgery of the Spine Group of the Chinese Orthopedic Association were significantly better at the last follow-up than that preoperatively in 135 patients(P<0.05).(3)At the last follow-up,there was no significant difference in physiological curvature of lumbar vertebra as compared with that preoperatively in 135 patients(P>0.05),with a fusion rate of 95.8%.(4)It is concluded that uniaxial spinal endoscopic intervertebral fusion combined with posterior percutaneous pedicle screw fixation in the treatment of lumbar degenerative diseases has shown satisfactory early clinical results and is a highly safe minimally invasive spinal surgery mode.

20.
J Orthop Surg Res ; 18(1): 950, 2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-38082370

RESUMEN

OBJECTIVE: Although spinal endoscopic techniques have shown great advantages in the treatment of single-segment lumbar disk herniation (LDH), the therapeutic advantages for double-segment LDH are controversial. To compare the outcomes of percutaneous endoscopic interlaminar discectomy (PEID) versus conventional open lumbar discectomy (COLD) for the treatment of L4/5 and L5/S1 double-segmental LDH. METHODS: From January 2016 to September 2021, we included 50 patients with double-segmental LDH who underwent PEID (n = 25) or COLD (n = 25). The clinical outcomes between the two groups were evaluated using the visual analog scale (VAS), the Oswestry disability index (ODI), and the modified MacNab criteria. Moreover, the incision length, operation time, intraoperative fluoroscopy time, postoperative bedtime, hospital stays, and complications were also recorded and compared after surgery. RESULTS: In both groups, the VAS and ODI scores at different timepoints postoperatively were significantly improved compared with those preoperatively (P < 0.05) According to the modified MacNab criteria, the excellent or good outcome rate was 92% in the PEID group and 88% in the COLD group. The PEID group had shorter incision length, postoperative bedtime, and hospital stays than the COLD group. However, the operation time was shorter and intraoperative fluoroscopy time was fewer in the COLD group. In addition, there was no significant difference between the two groups in terms of surgical complications during the postoperative follow-up period. CONCLUSIONS: Both PEID and COLD have good efficacy and high safety for management of L4/5 and L5/S1 double-segmental LDH. Compared with the COLD group, the PEID group had more operative time as well as more intraoperative fluoroscopy, but it had a more minimally invasive surgical incision as well as faster postoperative recovery.


Asunto(s)
Discectomía Percutánea , Desplazamiento del Disco Intervertebral , Humanos , Desplazamiento del Disco Intervertebral/diagnóstico por imagen , Desplazamiento del Disco Intervertebral/cirugía , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Estudios Retrospectivos , Endoscopía/métodos , Discectomía Percutánea/métodos , Discectomía/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA