RESUMEN
The largest uranium-phosphate deposit in Brazil also contains considerable levels of rare earth elements (REEs), which allows for the co-mining of these three ores. The most common methods for REE determination are time-consuming and demand complex sample preparation and use of hazardous reagents. Thus, the development of a safer and faster method to predict REEs in soil could aid in the assessment of these elements. We investigated the efficiency of near-infrared (NIR) spectroscopy to predict REEs in the soil of the uranium-phosphate deposit of Itataia, Brazil. We collected 50 composite topsoil samples in a well-distributed sampling grid along the deposit. The NIR measures in the soils ranged from 750 to 2500 nm. Three partial least squares regressions (PLSR) were selected to calibrate the spectra: full-spectrum partial least squares (PLS), interval partial least squares (iPLS), and successive projections algorithms for interval selection in partial least squares (iSPA-PLS). The concentrations of REEs were measured by inductively coupled plasma optical emission spectroscopy (ICP-OES). In addition to raw spectral data, we also used spectral pretreatments to investigate the effects on prediction results: multiplicative scatter correction (MSC), Savitzky-Golay derivatives (SG), and standard normal variate transformation (SNV). Positive results were obtained in PLS for La and ΣLREE using MSC pretreatment and in iSPA-PLS for Nd and Ce using raw data. The accuracy of the measurements was related to the REE concentration in soil; i.e., elements with higher concentrations tended to present more accurate results. The results obtained here aim to contribute to the development of NIR spectroscopy techniques as a tool for mapping the concentrations of REEs in topsoil.
Asunto(s)
Uranio , Brasil , Monitoreo del Ambiente , Análisis de los Mínimos Cuadrados , Fosfatos , Suelo , Espectroscopía Infrarroja CortaRESUMEN
Among the soil constituents, special attention is given to soil organic matter (SOM) and clay contents, since, among other aspects, they are key factors to nutrient retention and soil aggregates formation, which directly affect the crop production potential. The methods commonly used for the quantification of these constituents have some disadvantages, such as the use of chemical reactants and waste generation. An alternative to these methods is the near-infrared spectroscopy (NIRS) technique. The aim of this research is to evaluate models for SOM and clay quantification in soil samples using spectral data by NIRS. A set (n = 400) of soil samples previously analyzed by traditional methods were used to generate a NIRS calibration curve. The clay content was determined by the hydrometer method while SOM content was determined by sulfochromic solution. For calibration, we used the original spectra (absorbance) and spectral pretreatment (Savitzky-Golay smoothing derivative) in the following models: multiple linear regression (MLR), partial last squares regression (PLSR), support vector machine (SVM) and Gaussian process regression (GPR). The curve validation was performed with the SVM model (best performance in the calibration based on R² and RMSE) in two ways: with 40 random samples from the calibration set and another set with 200 new unknown samples. The soil clay content affects the predictive ability of the calibration curve to estimate SOM content by NIRS. Validation curves showed poorer performance (lower R² and higher RMSE) when generated from unknown samples, where the model tends to overestimate the lower levels and to underestimate the higher levels of clay and SOM. Despite the potential of NIRS technique to predict these attributes, further calibration studies are still needed to use this technique in soil analysis laboratories.(AU)
Dentre os constituintes do solo, especial atenção é voltada aos teores de argila e de matéria orgânica do solo (MOS), pois, entre outros aspectos, são determinantes para retenção de nutrientes e a formação de agregados no solo, os quais afetam diretamente o potencial produtivo das culturas. Os métodos mais comumente utilizados para quantificação destes constituintes apresentam algumas desvantagens, como o uso de reagentes químicos e a geração de resíduos. Uma alternativa a estes métodos é o uso da espectroscopia no infravermelho próximo (near infrared spectroscopy - NIRS). O objetivo deste trabalho é avaliar modelos de quantificação dos teores de argila e de MOS em amostras de solo utilizando dados espectrais por meio da técnica NIRS. Foram utilizadas 400 amostras de solos com amplitude nos teores de MOS e argila para geração de uma curva de calibração. A argila foi determinada pelo método do densímetro e a MOS por meio da solução sulfocrômica. Para calibração, utilizou-se os espectros originais (absorbância) e com pré-tratamento espectral (Savitzky-Golay derivative) das 400 amostras nos seguintes modelos: multiple linear regression (MLR), partial last squares regression (PLSR), support vector machine (SVM) e Gaussian process regression (GPR). A validação da curva foi realizada com o modelo que apresentou melhor desempenho na calibração (SVM) de duas maneiras: com 40 amostras aleatórias oriundas daquelas utilizadas na calibração e com outras 200 novas amostras desconhecidas. O teor de argila das amostras de solo afeta a capacidade preditiva da curva de calibração da estimativa do teor de MOS pelo NIRS. A validação das curvas apresentou pior desempenho (menor R² e maior RMSE) quando feita a partir de amostras desconhecidas, cujo modelo tende a superestimar os teores mais baixos e subestimar os teores mais elevados de argila e MOS...(AU)
Asunto(s)
Características del Suelo/análisis , Química del Suelo/análisis , Arcilla , Materia Orgánica/análisis , Espectroscopía Infrarroja CortaRESUMEN
ABSTRACT: Among the soil constituents, special attention is given to soil organic matter (SOM) and clay contents, since, among other aspects, they are key factors to nutrient retention and soil aggregates formation, which directly affect the crop production potential. The methods commonly used for the quantification of these constituents have some disadvantages, such as the use of chemical reactants and waste generation. An alternative to these methods is the near-infrared spectroscopy (NIRS) technique. The aim of this research is to evaluate models for SOM and clay quantification in soil samples using spectral data by NIRS. A set (n = 400) of soil samples previously analyzed by traditional methods were used to generate a NIRS calibration curve. The clay content was determined by the hydrometer method while SOM content was determined by sulfochromic solution. For calibration, we used the original spectra (absorbance) and spectral pretreatment (Savitzky-Golay smoothing derivative) in the following models: multiple linear regression (MLR), partial last squares regression (PLSR), support vector machine (SVM) and Gaussian process regression (GPR). The curve validation was performed with the SVM model (best performance in the calibration based on R² and RMSE) in two ways: with 40 random samples from the calibration set and another set with 200 new unknown samples. The soil clay content affects the predictive ability of the calibration curve to estimate SOM content by NIRS. Validation curves showed poorer performance (lower R² and higher RMSE) when generated from unknown samples, where the model tends to overestimate the lower levels and to underestimate the higher levels of clay and SOM. Despite the potential of NIRS technique to predict these attributes, further calibration studies are still needed to use this technique in soil analysis laboratories.
RESUMO: Dentre os constituintes do solo, especial atenção é voltada aos teores de argila e de matéria orgânica do solo (MOS), pois, entre outros aspectos, são determinantes para retenção de nutrientes e a formação de agregados no solo, os quais afetam diretamente o potencial produtivo das culturas. Os métodos mais comumente utilizados para quantificação destes constituintes apresentam algumas desvantagens, como o uso de reagentes químicos e a geração de resíduos. Uma alternativa a estes métodos é o uso da espectroscopia no infravermelho próximo (near infrared spectroscopy - NIRS). O objetivo deste trabalho é avaliar modelos de quantificação dos teores de argila e de MOS em amostras de solo utilizando dados espectrais por meio da técnica NIRS. Foram utilizadas 400 amostras de solos com amplitude nos teores de MOS e argila para geração de uma curva de calibração. A argila foi determinada pelo método do densímetro e a MOS por meio da solução sulfocrômica. Para calibração, utilizou-se os espectros originais (absorbância) e com pré-tratamento espectral (Savitzky-Golay derivative) das 400 amostras nos seguintes modelos: multiple linear regression (MLR), partial last squares regression (PLSR), support vector machine (SVM) e Gaussian process regression (GPR). A validação da curva foi realizada com o modelo que apresentou melhor desempenho na calibração (SVM) de duas maneiras: com 40 amostras aleatórias oriundas daquelas utilizadas na calibração e com outras 200 novas amostras desconhecidas. O teor de argila das amostras de solo afeta a capacidade preditiva da curva de calibração da estimativa do teor de MOS pelo NIRS. A validação das curvas apresentou pior desempenho (menor R² e maior RMSE) quando feita a partir de amostras desconhecidas, cujo modelo tende a superestimar os teores mais baixos e subestimar os teores mais elevados de argila e MOS com a curva gerada. Apesar do potencial de predição destes atributos via NIRS, outros estudos de calibração ainda são necessários para que esta técnica possa ser utilizada em laboratórios de análises de solos.