BMC Oral Health ; 21(1): 482, 2021 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-34583658

RESUMEN

BACKGROUND: To investigate the efficacy of a nickel-titanium (NiTi) file with an automated computerized numerical control (CNC) system for root canal shaping. METHODS: The movement of the automated device and the insertion angle were investigated. In Experiment 1, simulated resin root canals were randomly divided into four groups (n = 20): manual downward movement using a handpiece (Group 1), vertical downward movement by CNC (Group 2), reciprocating up and down movement by CNC (Group 3), and spiral up and down movement by CNC (Group 4). In Experiment 2, five different insertion angles of the NiTi file were evaluated (n = 20). Four parameters were used to evaluate the shaping ability: change in the working length, central axis offset, curvature variation, and preparation time. Groups were compared using one-way analysis of variance (ANOVA) with significance was set at P < 0.05. RESULTS: The change in central axis position in the curved part of the root canal was found to be smaller in Group 4 than in other groups (P < 0.05). The curvature changes and preparation time of Groups 1 and 4 were significantly reduced compared with Groups 2 and 3 (P < 0.05). The variation in working length and curvature in the 5° insertion angle group was significantly smaller than in the other groups (P < 0.05). CONCLUSIONS: A spiral up and down movement, controlled by the CNC machine, and 5° insertion angle, maintained original root canal shape more precisely than other methods.


Asunto(s)
Cavidad Pulpar , Níquel , Aleaciones Dentales , Diseño de Equipo , Humanos , Preparación del Conducto Radicular , Titanio
2.
Restor Dent Endod ; 37(4): 215-9, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23429968

RESUMEN

OBJECTIVES: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. MATERIALS AND METHODS: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer) were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. RESULTS: Group 4 showed lowest screw-in effect (2.796 ± 0.134) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. CONCLUSIONS: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.

3.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-10258

RESUMEN

OBJECTIVES: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. MATERIALS AND METHODS: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer) were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. RESULTS: Group 4 showed lowest screw-in effect (2.796 +/- 0.134) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. CONCLUSIONS: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.


Asunto(s)
Cavidad Pulpar , Polimetil Metacrilato , Torque
4.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-151373

RESUMEN

OBJECTIVES: The introduction of nickel-titanium alloy endodontic instruments has greatly simplified shaping the root canal systems. However, these new instruments have several unexpected disadvantages. One of these is tendency to screw into the canal. In this study, the influence of taper on the screw-in effect of the Ni-Ti rotary instrument were evaluated. MATERIALS AND METHODS: A total of 20 simulated root canals with an S-shaped curvature in clear resin blocks were divided into two groups. ProFile .02, .04, .06 (Dentsply-Maillefer) and GT rotary files .08, .10, .12 (Dentsply) were used in Profile group, and K3 .04, .06, .08, .10, and .12 (SybronEndo, Glendora) were used in K3 group. Files were used with a single pecking motion at a constant speed of 300 rpm. A special device was made to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in computer with designed software. The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. p value of less than 0.05 was regarded significant. RESULTS: The more tapered instruments generated more screw-in forces in Profile group (p < 0.05). In K3 group, 0.08, 0.10. and 0.12 tapered instruments showed more screw-in force than 0.04 tapered one, and 0.08 and 0.12 tapered instruments showed more screw-in force than 0.06 tapered one (p < 0.05). CONCLUSIONS: The more tapered instruments seems to produce more screw-in force. To avoid this screw-in force during instrumentation, more attention may be needed when using more tapered instruments.


Asunto(s)
Aleaciones , Cavidad Pulpar , Níquel , Titanio
5.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-151374

RESUMEN

OBJECTIVES: Nickel-titanium (Ni-Ti) rotary instruments have some unexpected disadvantages including the tendency to screw-in to the canal. The purpose of this study was to evaluate the influence of root canal curvatures on the screw-in effect of Ni-Ti rotary files. MATERIALS AND METHODS: A total of 80 simulated root canals in clear resin blocks were used in the study. Canals with curvature of 0, 10, 20 and 30 degrees were instrumented with ProTaper instruments SX, S1, S2 and a ProFile of #25/0.06 to 1.0-2.0 mm beyond the initial point of root curvature. The screw-in force was measured with a specially designed device while canal was instrumented with a ProFile of #30/0.06 at a constant speed of 300 rpm. The data were subjected to one-way ANOVA and Scheffe multiple range test for post-hoc test. RESULTS: Larger degree of canal curvature generated significantly lesser screw-in forces in all groups (p < 0.001). CONCLUSIONS: More attention needs to be paid when using rotary instruments in canals with less curvature than canals with more curvatures to prevent or reduce any accidental overinstrumentation.


Asunto(s)
Cavidad Pulpar , Níquel , Titanio
6.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-214636

RESUMEN

Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: K3(TM) (SybronEndo, Glendora, CA, USA), Mtwo (VDW GmbH, Munchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile(R) (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper(R) (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper(R), S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper(R) produced significantly more screw-in effects than any other instruments in the study (p 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular