Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 8306, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594338

RESUMEN

The creep response of the 17-4PH martensitic age-hardening steel in H1150 state was investigated at 427 and 482 °C. Hardness measurements of the heads of the creep samples demonstrated that the material underwent additional age hardening during the high-temperature exposure. Microstructural investigations confirmed that the additional precipitation of carbides and the G-phase occurred at the lowest temperature. A set of constitutive equations previously developed to describe the creep response of particle-strengthened alloys was successfully used to obtain a comprehensive description of the experimental data. The value of the particle strengthening term was obtained from the hardness measurements and corresponded to the Orowan stress. The model accurately described the observed minimum creep rate dependence on the applied stress and explained the occurrence of lower values of the minimum strain rate observed during variable-load experiments.

2.
Sensors (Basel) ; 23(3)2023 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-36772668

RESUMEN

In this study, the short-term creep effect (STCE) on strain transfer from fiber-reinforced polymer (FRP) strips to fiber Bragg grating-optical fiber (FBG-OF) sensors was investigated. Thirty OF sensors attached to FRP strips were investigated through three primary test parameters: bond length (40, 60, 80, 100, 120, and 150 mm); adhesive type (epoxy resin, CN adhesive, and epoxy resin combined with CN adhesive); and bonding method (embedded and external bonding methods). The strain transfer ability of the OF sensors was evaluated based on the strain ratio of the OF sensor to the FRP strip under different sustained stresses of 20, 40, 50, and 60% of the FRP ultimate tensile strength (fu). From the test results, it was found that the debonding phenomenon occurred at the interface between the FBG-OF sensor and the adhesive and was clearly observed after applying a load for three days. It was also found that the CN adhesive showed better strain transfer compared to the other adhesive types. Regarding the OF sensors bonded by epoxy resin, in order to maintain strain transfer ability under a high level of sustained stress (0.6fu), minimum bond lengths of 100 and 120 mm were required for the embedded and external bonding methods, respectively.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA