Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Materials (Basel) ; 15(10)2022 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-35629543

RESUMEN

Severe shot peening (SSP) was used on additive manufactured 316L by laser powder bed fusion. The effect of the post processing on the surface features of the material was analyzed through residual stress measurements, tensile testing, hardness-depth profiles, and fatigue testing by flexural bending. The results showed that SSP can be utilized to form residual stresses up to -400 MPa 200 µm below the surface. At the same time, a clear improvement on the surface hardness was achieved from 275 HV to near 650 HV. These together resulted in a clear improvement on material strength which was recorded at 10% improvement in ultimate tensile strength. Most significantly, the fatigue limit of the material was tripled from 200 MPa to over 600 MPa and the overall fatigue strength raised similarly from a low to high cycle regime.

2.
J Mech Behav Biomed Mater ; 119: 104476, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33838446

RESUMEN

Impact based surface treatments with adequate kinetic energy have favorable effects on promoting cell-substrate interactions, reducing bacterial adhesion, and enhancing fatigue performance of metallic biomaterials. Here, we used both numerical and experimental approaches to evaluate the potential of these treatments for addressing the major issue associated with the application of pure iron in biomedical implants, i.e. its low corrosion rate. Despite the efficiency of impact based surface treatments in modulating the degradation rate of pure iron, the maximum reported depth of the affected surface layer is still limited, even when extreme process parameters are used. To address this issue, herein, two impact based treatments were adjusted to trigger the dislocation activities that facilitate grain refinement in pure iron using multi-directional inclined impacts. An alternative approach of severe shot peening (SSP) was developed and compared with ultrasonic shot peening (USP). The effect of both treatments and variations of their key parameters were analyzed considering the significant role of shear bands and dislocation cells in the grain refinement mechanism of pure α-iron. Microstructural, mechanical and electrochemical properties of the treated material were analyzed. The observations showed extension of the grain refined layers for the specimens subjected to multidirectional oblique impacts compared to the ones treated in the classic manner using normal impacts. The results imply that by adapting peening parameters, it would be possible to effectively create a thick surface layer with properties that can accelerate the biodegradation of pure iron boosting its potential to meet clinical requirements for temporary hard tissue implants.


Asunto(s)
Materiales Biocompatibles , Hierro , Corrosión , Prótesis e Implantes , Propiedades de Superficie
3.
Acta Biomater ; 98: 88-102, 2019 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-31100463

RESUMEN

Pure iron and its biocompatible and biodegradable alloys have a high potential to be used for temporary load bearing medical implants. Nevertheless, the formation of passive iron oxide and hydroxide layers, which lead to a considerably low degradation rate at the physiological environment, has highly restricted their application. Herein we used numerical and experimental methods to evaluate the effect of severe shot peening, as a scalable mechanical surface treatment, on adjusting the performance of pure iron for biomedical applications. The developed numerical model was used to identify the range of peening parameters that would promote grain refinement on the pure iron surface. Experimental tests were then performed to analyze the gradient structure and the characteristics of the interface free surface layer created on peened samples. The results indicated that severe shot peening could notably increase the surface roughness and wettability, induce remarkable surface deformation and grain refinement, enhance surface hardness and generate high in-depth compressive residual stresses. The increased surface roughness besides the high concentration of micro cracks and dislocation density in the grain refined top layer promoted pure iron's degradation in the biologically simulated environment. STATEMENT OF SIGNIFICANCE: Biodegradable metallic materials with resorbable degradation products have a high potential to be used for temporary implants such as screws, pins, staples, etc. They can eliminate the need for implant retrieval surgery after the damaged tissue is healed, and result in reduced patient suffering besides lowered hospitalization costs. Pure iron is biodegradable and is an essential nutrient in human body; however, its application as biomedical implant is highly restricted by its slow degradation rate in physiological environment. We applied a scalable surface treatment able to induce grain refinement and increase surface roughness. This treatment enhances mechanical performance of pure iron and accelerates its degradation rate, paving the way for its broader applications for biomedical implants.


Asunto(s)
Materiales Biocompatibles/química , Hierro/química , Fenómenos Mecánicos , Simulación por Computador , Electroquímica , Análisis de Elementos Finitos , Análisis Numérico Asistido por Computador , Estrés Mecánico , Propiedades de Superficie
4.
Acta Biomater ; 66: 93-108, 2018 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-29183850

RESUMEN

The application of biodegradable magnesium-based materials in the biomedical field is highly restricted by their low fatigue strength and high corrosion rate in biological environments. Herein, we treated the surface of a biocompatible magnesium alloy AZ31 by severe shot peening in order to evaluate the potential of surface grain refinement to enhance this alloy's functionality in a biological environment. The AZ31 samples were studied in terms of micro/nanostructural, mechanical, and chemical characteristics in addition to cytocompatibility properties. The evolution of surface grain structure and surface morphology were investigated using optical, scanning and transmission electron microscopy. Surface roughness, wettability, and chemical composition, as well as in depth-microhardness and residual stress distribution, fatigue behaviour and corrosion resistance were investigated. Cytocompatibility tests with osteoblasts (bone forming cells) were performed using sample extracts. The results revealed for the first time that severe shot peening can significantly enhance mechanical properties of AZ31 without causing adverse effects on the growth of surrounding osteoblasts. The corrosion behavior, on the other hand, was not improved; nevertheless, removing the rough surface layer with a high density of crystallographic lattice defects, without removing the entire nanocrystallized layer, provided a good potential for improving corrosion characteristics after severe shot peening and thus, this method should be studied for a wide range of orthopedic applications in which biodegradable magnesium is used. STATEMENT OF SIGNIFICANCE: A major challenge for most commonly used metals for bio-implants is their non-biodegradability that necessitates revision surgery for implant retrieval when used as fixation plates, screws, etc. Magnesium is reported among the most biocompatible metals that resorb over time without adverse tissue reactions and is indispensable for many biochemical processes in human body. However, fast and uncontrolled degradation of magnesium alloys in the physiological environment in addition to their inadequate mechanical properties especially under repeated loading have limited their application in the biomedical field. The present study providesdata on the effect of a relatively simple surface nanocrystallziation method with high potential to tailor the mechanical and chemical behavior of magnesium based material while maintaining its cytocompatibility.


Asunto(s)
Aleaciones/farmacología , Ensayo de Materiales/métodos , Nanoestructuras/química , Osteoblastos/citología , Células Cultivadas , Corrosión , Electroquímica , Humanos , Nanoestructuras/ultraestructura , Osteoblastos/efectos de los fármacos , Propiedades de Superficie
5.
Biomaterials ; 73: 185-97, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26410786

RESUMEN

Substrate grain structure and topography play major roles in mediating cell and bacteria activities. Severe plastic deformation techniques, known as efficient metal-forming and grain refining processes, provide the treated material with novel mechanical properties and can be adopted to modify nanoscale surface characteristics, possibly affecting interactions with the biological environment. This in vitro study evaluates the capability of severe shot peening, based on severe plastic deformation, to modulate the interactions of nanocrystallized metallic biomaterials with cells and bacteria. The treated 316L stainless steel surfaces were first investigated in terms of surface topography, grain size, hardness, wettability and residual stresses. The effects of the induced surface modifications were then separately studied in terms of cell morphology, adhesion and proliferation of primary human osteoblasts (bone forming cells) as well as the adhesion of multiple bacteria strains, specifically Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, and ampicillin-resistant Escherichia coli. The results indicated a significant enhancement in surface work hardening and compressive residual stresses, maintenance of osteoblast adhesion and proliferation as well as a remarkable decrease in the adhesion and growth of gram-positive bacteria (S. aureus and S. epidermidis) compared to non-treated and conventionally shot peened samples. Impressively, the decrease in bacteria adhesion and growth was achieved without the use of antibiotics, for which bacteria can develop a resistance towards anyway. By slightly grinding the surface of severe shot peened samples to remove differences in nanoscale surface roughness, the effects of varying substrate grain size were separated from those of varying surface roughness. The expression of vinculin focal adhesions from osteoblasts was found to be singularly and inversely related to grain size, whereas the attachment of gram-positive bacteria (S. aureus and S. epidermidis) decreased with increasing nanoscale surface roughness, and was not affected by grain refinement. Ultimately, this study demonstrated the advantages of the proposed shot peening treatment to produce multifunctional 316L stainless steel materials for improved implant functions without necessitating the use of drugs.


Asunto(s)
Adhesión Bacteriana , Nanoestructuras/química , Osteoblastos/citología , Acero Inoxidable/química , Materiales Biocompatibles , Adhesión Celular , Proliferación Celular , Fuerza Compresiva , Escherichia coli , Humanos , Metales/química , Microscopía Electrónica de Rastreo , Microscopía Fluorescente , Oseointegración , Osteoblastos/metabolismo , Osteoblastos/microbiología , Pseudomonas aeruginosa , Staphylococcus aureus , Staphylococcus epidermidis , Propiedades de Superficie , Humectabilidad , Difracción de Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA