1.
Diabetol Int ; 15(3): 447-455, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39101163

RESUMEN

Introduction: It is challenging for pregnant women with type 1 diabetes to maintain optimum glucose level to attain good neonatal outcomes. This study evaluated the efficacy of sensor-augmented insulin pump (SAP) with a predictive low-glucose suspend (PLGS) system in pregnant Japanese women with type 1 diabetes. Materials and methods: SAP with PLGS was used in 11 of the 22 women with type 1 diabetes who delivered between 2011 and 2021 at the two medical institutions in Japan. Glucose management, insulin delivery suspension time (IST) and neonatal outcomes were retrospectively studied. Results: In SAP with PLGS cases (n = 11), average glycated hemoglobin levels were < 6.5% throughout the pregnancy, and the time in range (TIR, 63-140 mg/dl) was > 70% in the second and third trimesters. PLGS was safely used without inducing ketoacidosis. Positive correlation was observed between IST and TIR (r = 0.62, p < 0.01). Negative correlation was observed between IST and time below range (TBR) (r = - 0.40, p = 0.02), and IST and time above range (TAR) (r = - 0.45, p = 0.01). Total daily insulin dose was adequately increased without increasing hypoglycemia. There was only one heavy-for-date HFD) infant among the 11 newborns in SAP with PLGS cases. In cases without SAP (n = 11), target glycemic levels were difficult to achieve and there were 5 HFD infants among the 11 newborns. Conclusion: SAP with PLGS was safely and effectively used in pregnant women with type 1 diabetes to achieve target glucose levels without increasing the risk of hypoglycemia, which may have led to good neonatal outcomes. Supplementary Information: The online version contains supplementary material available at 10.1007/s13340-024-00716-7.

2.
Endocrine ; 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39052201

RESUMEN

OBJECTIVE: To elucidate the fluctuations in glucose levels measured using CGM-metrics during the four distinct seasons of the year in individuals with type 1 diabetes mellitus (T1DM) using an intermittently scanned CGM (isCGM) device or sensor augmented pump (SAP). RESEARCH DESIGN AND METHODS: This retrospective, single-center study enrolled 93 individuals with T1DM who were equipped with an isCGM device or SAP at Kobe University Hospital. The subjects had a median age of 47.0 years [interquartile range, 37.0-62.0 years], 25 individuals (26.9%) were male, median body mass index was 22.0 kg/m2 [20.8-23.8 kg/m2], and median hemoglobin A1c level was 7.4% [6.9-8.0%]. CGM data were reviewed from January to December 2019, and the mean sensor glucose (SG) value, time above range (TAR), time in range (TIR), time below range (TBR), and standard deviation (SD) of SG were calculated for each season (spring, March-May; summer, June-August; autumn, September-November; winter, December-February). RESULTS: Seasonal fluctuations were detected for mean SG, TAR, TIR, and SD, with TIR being lower and mean SG, TAR, and SD being higher in cold seasons (spring or winter) than in warm seasons (summer or autumn). CONCLUSION: Seasonal fluctuations in CGM metrics should be taken into account in future studies performed to evaluate the favorable impact of CGM on glycemic management in individuals with T1DM.

4.
Diabetologia ; 67(7): 1235-1244, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38634887

RESUMEN

AIMS/HYPOTHESIS: This study compares the efficacy and safety of a tubeless, on-body automated insulin delivery (AID) system with that of a tubeless, on-body sensor-augmented pump (SAP). METHODS: This multicentre, parallel-group, RCT was conducted at 13 tertiary medical centres in South Korea. Adults aged 19-69 years with type 1 diabetes who had HbA1c levels of <85.8 mmol/mol (<10.0%) were eligible. The participants were assigned at a 1:1 ratio to receive a tubeless, on-body AID system (intervention group) or a tubeless, on-body SAP (control group) for 12 weeks. Stratified block randomisation was conducted by an independent statistician. Blinding was not possible due to the nature of the intervention. The primary outcome was the percentage of time in range (TIR), blood glucose between 3.9 and 10.0 mmol/l, as measured by continuous glucose monitoring. ANCOVAs were conducted with baseline values and study centres as covariates. RESULTS: A total of 104 participants underwent randomisation, with 53 in the intervention group and 51 in the control group. The mean (±SD) age of the participants was 40±11 years. The mean (±SD) TIR increased from 62.1±17.1% at baseline to 71.5±10.7% over the 12 week trial period in the intervention group and from 64.7±17.0% to 66.9±15.0% in the control group (difference between the adjusted means: 6.5% [95% CI 3.6%, 9.4%], p<0.001). Time below range, time above range, CV and mean glucose levels were also significantly better in the intervention group compared with the control group. HbA1c decreased from 50.9±9.9 mmol/mol (6.8±0.9%) at baseline to 45.9±7.4 mmol/mol (6.4±0.7%) after 12 weeks in the intervention group and from 48.7±9.1 mmol/mol (6.6±0.8%) to 45.7±7.5 mmol/mol (6.3±0.7%) in the control group (difference between the adjusted means: -0.7 mmol/mol [95% CI -2.0, 0.8 mmol/mol] (-0.1% [95% CI -0.2%, 0.1%]), p=0.366). No diabetic ketoacidosis or severe hypoglycaemia events occurred in either group. CONCLUSIONS/INTERPRETATION: The use of a tubeless, on-body AID system was safe and associated with superior glycaemic profiles, including TIR, time below range, time above range and CV, than the use of a tubeless, on-body SAP. TRIAL REGISTRATION: Clinical Research Information Service (CRIS) KCT0008398 FUNDING: The study was funded by a grant from the Korea Medical Device Development Fund supported by the Ministry of Science and ICT; the Ministry of Trade, Industry and Energy; the Ministry of Health and Welfare; and the Ministry of Food and Drug Safety (grant number: RS-2020-KD000056).


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Masculino , Persona de Mediana Edad , Adulto , Femenino , Insulina/administración & dosificación , Insulina/uso terapéutico , Glucemia/efectos de los fármacos , Glucemia/metabolismo , Glucemia/análisis , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Anciano , Hemoglobina Glucada/metabolismo , Hemoglobina Glucada/análisis , República de Corea , Automonitorización de la Glucosa Sanguínea/métodos , Adulto Joven
5.
Endocrine ; 85(2): 593-597, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38502365

RESUMEN

PURPOSE: Given the rarity and elderly onset of immune checkpoint inhibitor (ICI)-induced type 1 diabetes (ICI-T1DM), cases leading to delivery are rare. METHOD: To our knowledge, this is the first case report of childbirth in a patient with ICI-T1DM after cancer survival. A 32-year-old woman was started on Nivolumab for metastatic parotid cancers one year after total parotidectomy. RESULT: The patient developed ICI-T1DM after 43 cycles and started multiple daily insulin therapy and self-monitoring of blood glucose. Complete response was maintained for 2 years by nivolumab, and she finished nivolumab in 77 cycles to attempt pregnancy. During the follow-up period, she began using a sensor-augmented pump (SAP). She had undetectable serum and urinary C-peptide when she started SAP. Her HbA1c level decreased from 7.8 to 6.6% without increasing hypoglycemia in one year. The patient remained in complete response after ICI discontinuation, and embryo transfer was initiated. Pregnancy was confirmed after a second embryo transfer (21 months after ICI discontinuation). At 36 weeks and 6 days, an emergency cesarean section was performed due to the onset of preeclampsia. The baby had hypospadias and bifid scrotum but no other complications or neonatal intensive care unit admission. CONCLUSION: Because ICI discontinuation and ICI-T1DM carry risks for the patient and child, the decision regarding pregnancy warrants careful consideration. Diabetologists should collaborate with patients and other clinical departments to develop a treatment plan for childbirth.


Asunto(s)
Supervivientes de Cáncer , Diabetes Mellitus Tipo 1 , Inhibidores de Puntos de Control Inmunológico , Humanos , Femenino , Embarazo , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Adulto , Inhibidores de Puntos de Control Inmunológico/efectos adversos , Inhibidores de Puntos de Control Inmunológico/uso terapéutico , Cesárea , Nivolumab/efectos adversos , Nivolumab/uso terapéutico , Neoplasias de la Parótida/tratamiento farmacológico , Embarazo en Diabéticas/tratamiento farmacológico , Recién Nacido , Resultado del Embarazo
6.
Diabetes Technol Ther ; 26(8): 547-555, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38386437

RESUMEN

Objective: Examine gestational safety, glycemic and health outcomes, of a hybrid closed-loop (HCL) system without pregnancy-specific glucose targets. Research Design: This was a pilot feasibility investigator-initiated, two-site, single-blind, randomized controlled trial of sensor-augmented pump therapy (SAPT) versus HCL therapy in type 1 diabetes pregnancies. Participants were enrolled in the first trimester and randomized at 14-18 weeks of gestation and used SAPT or HCL until 4-6 weeks postpartum. We compared continuous glucose monitoring (CGM) metrics, severe hypoglycemia (SH), diabetic ketoacidosis (DKA), adverse skin reactions, and pregnancy outcomes between groups. Results: Baseline characteristics were similar between groups (n = 11 HCL and n = 12 SAPT). There was no SH or DKA episode after randomization. Time spent <54 mg/dL did not differ between groups. Time spent <63 mg/dL decreased in both groups, significantly in the HCL group (3.5% [1.3% standard error] second trimester and 2.8% [1.3%] third trimester vs. 7.9% [1.3%] run-in phase, P < 0.05 for both). Mean sensor glucose was lower with SAPT compared to HCL therapy in the third trimester (119 [4] mg/dL SAPT vs. 132 [4] mg/dL HCL, P < 0.05). Third trimester time-in-range (TIR; 63-140 mg/dL) increased with SAPT (68.2% [3.1%] vs. 64.3% [3.1%] run-in phase, P < 0.05). Gestational health outcomes did not differ between groups. The HCL group used assistive techniques, such as fake carbohydrate boluses and exiting HCL overnight. Conclusions: CGM within group differences were seen for time <63 mg/dL favoring HCL therapy and TIR favoring SAPT (third trimester vs. baseline). Safety and adverse pregnancy outcomes were similar between groups.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Embarazo en Diabéticas , Humanos , Embarazo , Femenino , Adulto , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/instrumentación , Método Simple Ciego , Embarazo en Diabéticas/tratamiento farmacológico , Embarazo en Diabéticas/sangre , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Insulina/administración & dosificación , Insulina/uso terapéutico , Proyectos Piloto , Resultado del Embarazo , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Cetoacidosis Diabética , Estudios de Factibilidad
7.
Intern Med ; 63(8): 1125-1130, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-37661453

RESUMEN

Total pancreatectomy results in complete loss of insulin and glucagon. Sensor-augmented pumps (SAPs) allow fine-tuning of the basal insulin rate, which helps avoid both hypo- and hyperglycemic events. We herein report a case of total pancreatectomy treated with a SAP with no evidence of ketoacidosis without any insulin administration during a certain period of time. Furthermore, we observed a sudden drop in blood glucose levels without insulin, which may have been due to glucose effectiveness. Our case is valuable in arguing the concept of glucose effectiveness in the absence of insulin and glucagon.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hiperglucemia , Cetosis , Humanos , Glucagón/uso terapéutico , Glucemia , Pancreatectomía , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Hiperglucemia/tratamiento farmacológico , Hiperglucemia/etiología , Glucosa , Hipoglucemiantes/uso terapéutico
8.
Curr Diabetes Rev ; 20(3): e310523217505, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37259938

RESUMEN

BACKGROUND: Type 1 diabetes mellitus (T1D) is a chronic disease that requires exogenous insulin administration and intensive management to prevent any complications. Recent innovations in T1D management technologies include the Advanced Hybrid Closed-Loop delivery system (AHCL). The pioneer AHCL system provides automated basal and automated bolus corrections when needed. OBJECTIVE: This study aimed to compare the Advanced Hybrid Closed-Loop (AHCL) system and the Sensor-Augmented Pump (SAP) with Predictive Low Glucose Management (PLGM) system, in relation to glycaemic outcomes, general and diabetes-related Quality of Life (QoL), and diabetes distress. METHODS: General and diabetes-related QoL were assessed with the Diabetes Quality of Life Brief Clinical Inventory (DQOL-BCI) and the World Health Organization Quality of Life-BREF (WHOQOL-BREF), respectively. Diabetes distress was assessed with the Diabetes Distress Scale for Type 1 diabetes (T1-DDS). RESULTS: Eighty-nine T1D adults participated in the study, mostly females (65.2%), with a mean age of 39.8 (± 11.5 years). They had on average 23 years of diabetes (± 10.7) and they were on continuous subcutaneous insulin infusion therapy. Significant differences favoring the AHCL over the SAP + PLGM system were demonstrated by lower mean glucose levels, less time above range, lower scores on DQOL-BCI, T1-DDS, and higher scores on WHOQOL-BREF. Finally, the linear regression models revealed the association of time in range in most of the above aspects. CONCLUSION: This study highlighted the advantages of the AHCL system over the SAP + PLGM system in the real-world setting in relation to general and diabetes-related QoL, diabetes distress, and glycaemic outcomes.


Asunto(s)
Diabetes Mellitus Tipo 1 , Enfermedades Pancreáticas , Adulto , Femenino , Humanos , Masculino , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Calidad de Vida , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Automonitorización de la Glucosa Sanguínea , Glucosa , Glucemia
9.
J Diabetes Investig ; 14(12): 1383-1390, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37706627

RESUMEN

AIMS/INTRODUCTION: To evaluate the efficacy of sensor-augmented pump (SAP) for improving obstetric and neonatal outcomes among pregnant women with type 1 diabetes mellitus by comparing it with continuous subcutaneous insulin infusion plus self-monitoring of blood glucose (continuous subcutaneous insulin infusion [CSII]/SMBG). MATERIALS AND METHODS: This retrospective cohort study included 40 cases of pregnancy complicated by type 1 diabetes mellitus treated with SAP (SAP group), and 29 cases of pregnancy complicated by type 1 diabetes mellitus treated with CSII/SMBG (CSII/SMBG group). The obstetric and neonatal outcomes were compared between the two groups. RESULTS: The median of the glycoalbumin levels in the first (18.8% vs 20.9%; P < 0.05) and second (15.4% vs 18.0%; P < 0.05) trimesters, the hemoglobin A1c levels in the peripartum period (6.1% vs 6.5%; P < 0.05) and the standard deviation score of birthweights (0.36 vs 1.52; P < 0.05) were significantly lower in the SAP group than in the CSII/SMBG group. The incidence rate of large for gestational age newborns was significantly lower in the SAP group than in the CSII/SMBG group (27.5% vs 65.5%; P < 0.05). No significant differences in the incidence rates of hypertensive disorders of pregnancy, small for gestational age, respiratory distress syndrome, neonatal hypoglycemia, hypervolemia and hyperbilirubinemia were observed between the groups. CONCLUSION: The present study showed that SAP therapy is more effective in preventing large for gestational age newborns in pregnant women with type 1 diabetes mellitus than CSII/SMBG.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hiperinsulinismo , Recién Nacido , Humanos , Femenino , Embarazo , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Mujeres Embarazadas , Estudios Retrospectivos , Automonitorización de la Glucosa Sanguínea , Insulina/uso terapéutico , Glucemia
10.
J Diabetes Investig ; 14(11): 1318-1320, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37494142

RESUMEN

Needle phobia is a specific phobia classified as an anxiety disorder in the Diagnostic and Statistical Manual of Mental Disorders-5, and can be a serious problem for patients requiring insulin injections. However, there have been few reports to date on the management of adults with diabetes and needle phobia. We here report a case of a woman with pancreatic diabetes who developed needle phobia and could no longer perform self-injections. She started to use a sensor-augmented pump (SAP), and was able to perform a puncture for the insulin pump and the continuous glucose monitoring sensor by herself. The SAP treatment achieved self-management, better glycemic control, and high treatment satisfaction quantified using the Diabetes Treatment Satisfaction Questionnaire in this patient. Our case suggests the therapeutic potential of SAP in adults with needle phobia and diabetes requiring insulin therapy.


Asunto(s)
Diabetes Mellitus Tipo 1 , Trastornos Fóbicos , Adulto , Femenino , Humanos , Hipoglucemiantes/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucemia , Automonitorización de la Glucosa Sanguínea , Insulina/uso terapéutico , Trastornos Fóbicos/tratamiento farmacológico
11.
Endocrinol Diabetes Nutr (Engl Ed) ; 70 Suppl 2: 55-59, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37236844

RESUMEN

INTRODUCTION: Technical issues related to continuous subcutaneous insulin infusion (CSII), associated or not with continuous glucose monitoring (SAP), are handled by tele-technical assistance from the manufacturer. We analyze the characteristics of the most demanding patients of technical teleassistance. MATERIAL AND METHODS: Patients with type 1 diabetes (T1D) in treatment with CSII or SAP, who made use of technical teleassistance from 01/01/2017 to 02/28/2021 (2298 consultations) were included. We selected the group of patients who made ≥10 calls (90th percentile, P90) and the one who made a single call (10th percentile, P10). The number and most frequent reasons for consultation, clinical characteristics and HbA1c were collected and both groups were compared. RESULTS: 51 patients (P90) made a total of 876 calls (38.1% of calls), 32 used SAP. The most frequent reason for consultation was related to continuous glucose monitoring (36.8%). 51 (P10) made 51 calls (2.2%), 3 used SAP. The most frequent reason for consultation was related to device damage (25.5%). The most demanding patients used SAP more frequently (62.7 vs. 5.9%, P < .001), had been in advanced treatment for less time (7.1 ±â€¯5.5 vs. 12.1 ±â€¯6.2 years, P < .001) and their HbA1c was lower (7.2 ±â€¯0.9 vs 7.6 ±â€¯0.8%). CONCLUSIONS: Most of the calls to the technical teleassistance service for ISCI/SAP devices come from a more demanding group of people with T1D. The greatest demand is concentrated in patients who use SAP, with a shorter time of use of advanced therapy and a better degree of glucose control.


Asunto(s)
Diabetes Mellitus Tipo 1 , Consulta Remota , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Automonitorización de la Glucosa Sanguínea , Glucemia , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Tecnología
12.
Acta Diabetol ; 60(7): 943-949, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37010594

RESUMEN

BACKGROUND AND AIMS: Evidence supports the efficacy and safety of the Hybrid Close loop (HCL) system in patients with type 1 diabetes (T1D). However, limited data are available on the long-term outcomes of patients on HCL with telemedicine follow-up. METHODS: A prospective observational cohort study including T1D patients, who were upgrading to HCL system. Virtual training and follow-up were done through telemedicine. CGM data were analyzed to compare the baseline time in range (TIR), time below range (TBR), glycemic variability and auto mode (AM), with measurements performed at 3, 6 and 12 months. RESULTS: 134 patients were included with baseline A1c 7.6% ± 1.1. 40.5% had a severe hypoglycemia event in the last year. Baseline TIR, measured two weeks after starting AM was 78.6 ± 9.94%. No changes were evident at three (Mean difference - 0.15;CI-2.47,2.17;p = 0.96), six (MD-1.09;CI-3.42,1.24;p = 0.12) and 12 months (MD-1.30;CI-3.64,1.04;p = 0.08). No significant changes were found in TBR or glycemic variability throughout the follow-up. Use of AM was 85.6 ± 17.5% and percentage of use of sensor was 88.75 ± 9.5% at 12 months. No severe hypoglycemic (SH) events were reported. CONCLUSIONS: HCL systems allow to improve TIR, TBR and glycemic variability safely, early and sustained up to 1 year of follow-up in patients with T1D and high risk of hypoglycemia followed through telemedicine.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Telemedicina , Humanos , Diabetes Mellitus Tipo 1/etiología , Insulina/uso terapéutico , Glucemia , Estudios Prospectivos , Sistemas de Infusión de Insulina/efectos adversos , Hipoglucemiantes/uso terapéutico , Hipoglucemia/etiología , Hipoglucemia/inducido químicamente , Automonitorización de la Glucosa Sanguínea
13.
J Diabetes Sci Technol ; : 19322968231156601, 2023 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-36840616

RESUMEN

AIM: Insulin pump, continuous glucose monitoring (CGM), and sensor augmented pump (SAP) technology have evolved continuously leading to the development of automated insulin delivery (AID) systems. Evaluation of the use of diabetes technologies in people with T1D from January 2018 to December 2021. METHODS: A patient registry (Diabetes Prospective Follow-up Database [DPV]) was analyzed for use of SAP (insulin pump + CGM ≥90 days, no automated dose adjustment) and AID (HCL or LGS/PLGS). In total 46,043 people with T1D aged 0.5 to <26 years treated in 416 diabetes centers (Germany, Austria, Luxemburg, and Switzerland) were included and stratified into 4 groups A-D according to age. Additionally, TiR and HbA1c were analyzed. RESULTS: From 2018 to 2021, there was a significant increase from 28.7% to 32.9% (sensor augmented pump [SAP]) and 3.5% to 16.6% (AID) across all age groups, with the most frequent use in group A (<7 years, 38.8%-40.2% and 10.3%-28.5%). A similar increase in SAP and AID use was observed in groups B (7 to <11 years) and C (11 to <16 years): B: +15.8 PP, C: +15.9 PP. HbA1c improved significantly in groups C and D (16 to <26 years) (both P < .01). Time in range (TiR) increased in all groups (A: +3 PP; B: +5 PP; C: +5 PP; D: +5 PP; P < 0.01 for each group). Insulin pumps (61.0% versus 53.4% male) and SAP (33.5% versus 28.9% male) are used more frequently in females. CONCLUSION: In recent years, we found an increasing use of new diabetes technologies and an improvement in metabolic control (TiR) across all age groups.

15.
Front Endocrinol (Lausanne) ; 13: 997296, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36157458

RESUMEN

Type B insulin resistance syndrome (TBIR) is a rare disease characterized by refractory diabetes due to severe insulin resistance caused by anti-insulin receptor autoantibodies, and a standard treatment regimen for TBIR has not been established, leading to therapeutic difficulties and high mortality. Since TBIR is known to be associated with autoimmune diseases such as systemic lupus erythematosus (SLE), glucocorticoids are often used as key immunosuppressive agents. However, glucocorticoids have the potential to exacerbate the pathophysiology of TBIR by worsening insulin sensitivity, which leads to hyperglycemia and muscle wasting. Here, we report a case history of a 66-year-old man who was diagnosed as having TBIR in combination with SLE and Sjögren's syndrome with marked hyperglycemia, ketosis, and muscle wasting. He was successfully treated with combination therapy of double-filtration plasmapheresis (DFPP) and administration of the anti-CD20 monoclonal antibody rituximab without induction of glucocorticoid therapy while using a sensor-augmented insulin pump (SAP) to prevent hypoglycemia. Remission of diabetes was achieved without severe hypoglycemic events and his circulating insulin receptor antibodies became negative after seven months of initiation of these treatments. Based on the successful clinical courses of this case, our report suggests the possibility of an effective therapeutic regimen with DFPP and rituximab under the condition of the use of an SAP for a patient with TBIR without induction of glucocorticoids.


Asunto(s)
Enfermedades Autoinmunes , Diabetes Mellitus , Hiperglucemia , Resistencia a la Insulina , Lupus Eritematoso Sistémico , Anciano , Anticuerpos Monoclonales/uso terapéutico , Autoanticuerpos , Diabetes Mellitus/tratamiento farmacológico , Glucocorticoides/uso terapéutico , Humanos , Hiperglucemia/complicaciones , Hipoglucemiantes/uso terapéutico , Inmunosupresores/uso terapéutico , Lupus Eritematoso Sistémico/complicaciones , Masculino , Plasmaféresis , Rituximab/uso terapéutico
16.
Clin Pediatr Endocrinol ; 31(3): 178-184, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35928380

RESUMEN

Neonatal diabetes mellitus (NDM) is a rare metabolic disorder that is mainly present in the first 6 months of life and necessitates insulin treatment. Sensor-augmented pump (SAP) therapy has been widely used in children with type 1 diabetes mellitus, but its use in patients with NDM is limited. We report three patients with NDM who received SAP therapy using the MiniMed™ 640G system starting in the neonatal period. Two patients were treated for 3 months, and one patient continued treatment up to an age of 22 mo. The MiniMed 640G system can automatically suspend insulin delivery (SmartGuard™ Technology) to avoid hypoglycemia when the sensor glucose level is predicted to approach the predefined threshold. We suggest that SmartGuard Technology is particularly useful for infants in whom hypoglycemia cannot be identified. The MiniMed 640G system automatically records the trends of sensor glucose levels and the total daily dose of insulin, which can make the management more accurate and reduce the family's effort. SAP therapy for patients with NDM automatically prevents severe hypoglycemia and is useful for long-term management; however, attention should be paid to its application.

17.
Diabetes Ther ; 13(9): 1645-1657, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35913656

RESUMEN

INTRODUCTION: The use of predictive low-glucose suspend (PLGS) sensor-augmented pumps has been shown to lead to a significant reduction in hypoglycemic episodes in patients with type 1 diabetes (T1D), but their effects on hyperglycemia exposure are heterogeneous. The aim of this study was to determine the settings of the Medtronic 640G system to obtain the optimal balance between occurrence of both hypoglycemia and hyperglycemia. METHODS: The hypo- and hyperglycemia area under the curve (AUC), as well as system settings [hypoglycemic threshold, mean insulin total daily dose (TDD), mean basal insulin percentage, and mean daily duration of PLGS] were collected between 2 and 12 times during 1 year in patients from four university hospital centers. Univariate/multivariate analyses and receiver operating characteristics (ROC) curves were performed to determine factors associated with hyper- and hypoglycemia AUC. RESULTS: A total of 864 observations were analyzed from 110 patients with T1D. Two preselected settings predictive of low hyperglycemia AUC were a basal insulin percentage < 52.0% [sensitivity (Se) = 0.66 and specificity (Sp) = 0.53] and a PLGS duration > 157.5 min/day (Se = 0.47 and Sp = 0.73). The preselected setting predictive of a low hypoglycemia AUC was a PLGS duration ≤ 174.4 min (Se = 0.83 and Sp = 0.51). Between-visit variation of PLGS and TDD was positively correlated (r = 0.61; p < 0.0001). CONCLUSION: The most important Medtronic 640G setting was the mean daily PLGS duration, where a value between 157.5 and 174.4 min/day was associated with the best reduction in both hypo- and hyperglycemia AUC. In this study, we showed that PLGS duration could be indirectly modified through total daily insulin dose adaptation. TRIAL REGISTRATION: This study is registered in clinicaltrials.gov (NCT03047486).

18.
Diabetes Technol Ther ; 24(9): 666-671, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35575751

RESUMEN

Sleep-related effects of closed-loop therapy among older adults with type 1 diabetes have not been well established. In the OldeR Adult Closed-Loop (ORACL) randomized, crossover trial of first-generation closed-loop therapy (MiniMed 670G), participants wore actigraphy and completed sleep diaries for 14-day periods at stage end. During objectively measured sleep (actigraphy) with closed-loop versus sensor-augmented pump therapy, glucose time-in-range 70-180 mg/dL (3.9-10.0 mmol/L) was greater (90.3% vs. 78.7%, respectively; difference 8.2 percentage points [95% confidence interval {CI} 1.5 to 13.0]; P = 0.008), and there were fewer sensor hypoglycemia episodes (18 vs. 43, respectively; incident rate ratio 0.40 [95% CI 0.20 to 0.55]; P = 0.007). Sleep quality recorded daily was worse with closed-loop therapy (P = 0.006); Pittsburgh Sleep Quality Index did not differ. There were 30% more system alarms during monitored sleep with closed-loop therapy (P < 0.001). First-generation closed-loop therapy has important glycemic benefits during sleep for older adults, with deterioration in some sleep quality measures. Sleep quality warrants prioritization and investigation during advancement of closed-loop technology.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Anciano , Glucemia , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéutico , Sueño , Calidad del Sueño
19.
Diabet Med ; 39(7): e14828, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35274356

RESUMEN

AIMS: To explore parents' experiences of using remote monitoring technology when caring for a very young child with type 1 diabetes during a clinical trial. METHODS: Interviews were conducted with parents of 30 children (aged 1-7 years) participating in a trial (the KidsAP02 study) comparing hybrid closed-loop insulin delivery with sensor-augmented pump therapy. In both arms, parents had access to remote monitoring technology. Data analysis focused on identification of descriptive themes. RESULTS: Remote monitoring technology gave parents improved access to data which helped them pre-empt and manage glucose excursions. Parents observed how, when children were in their own care, they could be more absent while present, as their attention could shift to non-diabetes-related activities. Conversely, when children were others' care, remote monitoring enabled parents to be present while absent, by facilitating oversight and collaboration with caregivers. Parents described how remote monitoring made them feel more confident allowing others to care for their children. Parents' confidence increased when using a hybrid closed-loop system, as less work was required to keep glucose in range. Benefits to children were also highlighted, including being able to play and sleep uninterrupted and attend parties and sleepovers without their parents. While most parents welcomed the increased sense of control remote monitoring offered, some noted downsides, such as lack of respite from caregiving responsibilities. CONCLUSIONS: Remote monitoring can offer manifold benefits to both parents and very young children with type 1 diabetes. Some parents, however, may profit from opportunities to take 'time out'.


Asunto(s)
Diabetes Mellitus Tipo 1 , Padres , Tecnología de Sensores Remotos , Glucemia , Automonitorización de la Glucosa Sanguínea , Niño , Preescolar , Ensayos Clínicos como Asunto , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Lactante , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Padres/psicología
20.
Diabetol Int ; 13(1): 280-287, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35059264

RESUMEN

OBJECTIVE: Sensor-augmented pump (SAP) therapy reportedly improves glycemic control and quality of life. However, there is limited information on changes in awareness of hypoglycemia and quality of life (QOL) after starting SAP therapy in Japanese patients with type 1 diabetes. The aim of this study was to evaluate glycemic control, awareness of hypoglycemia, and QOL after initiation of SAP therapy in these patients. METHODS: The study included 20 patients with type 1 diabetes who started SAP therapy. HbA1c levels, values derived from continuous glucose monitoring [including percentages of time in target range (70-180 mg/dL), time below range (< 70 mg/dL), and time above range (> 180 mg/dL)], the Diabetes Treatment Satisfaction Questionnaire score, and the Clarke score were compared between baseline and after 3 and 6 months of SAP therapy. RESULTS: There was a significant decrease in HbA1c at 3 and 6 months after starting on the SAP (p < 0.0001). There was also a significant decrease in time above range (> 180 mg/dL) at the two time points (p = 0.0069 and p = 0.0042, respectively). There was no significant change in time below range (< 70 mg/dL). There was a significant reduction in the Clarke score (p = 0.0347 and p = 0.0003, respectively) and a significant increase in the treatment satisfaction score (both p < 0.0001). There was no significant change in any of the three MOS 36-Item Short-Form Health Survey v2 component summary scores. CONCLUSION: SAP therapy was associated with improvement of glycemic control, mainly by reducing hyperglycemia, and patients' satisfaction with treatment.