RESUMEN
AIM: CT images can identify structural and opacity alterations of the lungs while nuclear medicine's lung perfusion studies show the homogeneity (or lack of) of blood perfusion on the organ. Therefore, the use of SPECT/CT in lung perfusion scintigraphies can help physicians to assess anatomical and functional alterations of the lungs and to differentiate between acute and chronic disease. OBJECTIVE: To develop a computer-aided methodology to quantify the total global perfusion of the lungs via SPECT/CT images and to compare these results with parenchymal alterations obtained in CT images. METHODS: 39 perfusion SPECT/CT images collected retrospectively from the Nuclear Medicine Facility of Botucatu Medical School's Clinics Hospital in São Paulo, Brazil, were analyzed. Anatomical lung impairments (emphysema, collapsed and infiltrated tissue) and the functional percentage of the lungs (blood perfusion) were quantified from CT and SPECT images, with the aid of the free, open-source software 3D Slicer. The results obtained with 3D Slicer (3D-TGP) were also compared to the total global perfusion of each patient's found on their medical report, obtained from visual inspection of planar images (2D-TGP). RESULTS: This research developed a novel and practical methodology for obtaining lungs' total global perfusion from SPECT/CT images in a semiautomatic manner. 3D-TGP versus 2D-TGP showed a bias of 7% with a variation up to 67% between the two methods. Perfusion percentage showed a weak positive correlation with infiltration (p = 0.0070 and ρ = 0.43) and collapsed parenchyma (p = 0.040 and ρ = 0.33). CONCLUSIONS: This research brings meaningful contributions to the scientific community because it used a free open-source software to quantify the lungs blood perfusion via SPECT/CT images and pointed that the relationship between parenchyma alterations and the organ's perfusion capability might not be so direct, given compensatory mechanisms.
Asunto(s)
Pulmón , Imagen de Perfusión , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Humanos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Pulmón/diagnóstico por imagen , Pulmón/irrigación sanguínea , Estudios Retrospectivos , Masculino , Femenino , Imagen de Perfusión/métodos , Persona de Mediana Edad , Anciano , Procesamiento de Imagen Asistido por Computador/métodos , Adulto , Anciano de 80 o más AñosRESUMEN
PURPOSE: To study the clinical diagnostic value of SPECT/CT bone imaging combined with two serum examinations in patients with bone metastases from pulmonary cancer. METHODS: The clinical data of 120 patients consistent with pulmonary cancer admitted to the First Affiliated Hospital of Hebei North University from March 2019 to December 2019 were selected for retrospective analysis, and they were divided into the bone metastasis group (n = 58) and non-bone metastasis group (n = 62) according to comprehensive evaluation result of X-ray, CT, MRI and clinical follow-up. The CT values of patients were obtained by SPECT/CT bone imaging to compare serum levels of ALP (alkaline phosphatase belongs to phosphoric monoester hydrolases, as a specific phosphatase, mainly in body tissues and body fluid) and BAP (bone alkaline phosphatase is formed by different modification and processing of alkaline phosphatase, and is mainly released by osteoblasts) and CT values of patients in both groups, using receiver operating characteristic (ROC) curve to evaluate the diagnostic efficacy of single detection and combined detection. RESULTS: SPECT/CT bone imaging in patients with bone metastasis from pulmonary cancer showed abnormal radioactive accumulation in spine, pelvis and bilateral ribs. Serum ALP, BAP and CT values in bone metastasis group were overtly higher than the non-bone metastasis group (P < 0.001). Logistic regression analysis showed that serum ALP, BAP and CT value were independent risk factors for bone metastasis from pulmonary cancer. The AUC value and Youden index of combined diagnosis were higher than those of single diagnosis. CONCLUSION: SPECT/CT bone imaging combined with serum detection of ALP and BAP in patients with pulmonary cancer is helpful for early diagnosis of bone metastasis, which provides more basis for the formulation and selection of clinical treatment options.
Asunto(s)
Neoplasias Óseas , Neoplasias Pulmonares , Humanos , Fosfatasa Alcalina , Estudios Retrospectivos , Tomografía Computarizada de Emisión de Fotón Único , Neoplasias Pulmonares/patología , Tomografía Computarizada por Rayos XRESUMEN
Introducción: la amiloidosis cardíaca (AC) es una miocardiopatía infiltrativa producida por depósito miocárdico extracelular de amiloide. Las variantes más frecuentes son debidas a cadenas ligeras de inmunoglobulinas o transtiretina (ATTR). El centellograma con 99mTc-pirofosfato (99mTc-PYP) es una técnica de imagen molecular que permite diferenciar los subtipos más frecuentes de AC. El presente estudio analizó el rol del 99mTc-PYP y el SPECT-CT en la evaluación de pacientes con sospecha clínica de AC. Materiales y métodos: se realizó 99mTc-PYP y SPECT-CT en 16 pacientes con sospecha clínica de AC, con edad promedio de 63 años. Se realizó análisis cualitativo de las imágenes planares y del SPECT-CT (Mediso, AnyScan), adquiridas 1-3 horas tras la inyección del radiotrazador. Para el análisis cuantitativo de las imágenes planares se calculó la relación H/CL (cuentas promedio obtenidas sobre las regiones de interés del corazón y el hemitórax contralateral). El estudio se consideró positivo para ATTR cuando la relación H/CL fue ≥1.5. Las imágenes de SPECT-CT fueron interpretadas para observar la distribución del trazador a nivel cardíaco y extracardíaco. Resultados: se identificó captación miocárdica de 99mTc-PYP en el ventrículo izquierdo en 6 pacientes y en el ventrículo derecho en 3 pacientes. En estos casos, la relación H/CL fue >1.5. En el resto se descartó la captación miocárdica, con relación H/CL<1.5. Se detectó actividad de pool vascular en las imágenes tomográficas de 7 pacientes y captación extracardíaca ósea anormal de causas traumáticas/degenerativas en 9 pacientes. Cinco pacientes presentaron captación hepática difusa, sin alteración estructural en el TC. Conclusiones: el 99mTc-PYP es una técnica clínicamente relevante en pacientes con sospecha de AC. Constituye una herramienta mínimamente invasiva, ampliamente disponible, de bajo costo y útil en el diagnóstico, pudiendo orientar al subtipo de AC. La información que aporta permite además orientar las opciones terapéuticas y brindar información pronóstica adicional.
Introduction: Cardiac amyloidosis (CA) is an infiltrative cardiomyopathy caused by extracellular myocardial amyloid deposition. The most frequent variants are due to immunoglobulin light chains or transthyretin (ATTR). 99mTc-pyrophosphate (99mTc-PYP) scintigraphy is a molecular imaging technique that allows differentiation of the most common subtypes of AC. The present study analyzed the role of 99mTc-PYP and SPECT-CT in the evaluation of patients with clinical suspicion of CA. Materials and methods: 99mTc-PYP and SPECT-CT were performed in 16 patients with clinical suspicion of AC, with an average age of 63 years. Qualitative analysis was performed on the planar and SPECT-CT images (Mediso, AnyScan), acquired 1-3 hours after the injection of the radiotracer. For the quantitative analysis of the planar images, the H/CL ratio (average counts obtained over the regions of interest of the heart and the contralateral hemithorax) was calculated. The study was considered positive for ATTR when the H/CL ratio was ≥1.5. The SPECT-CT images were interpreted to observe the distribution of the tracer at the cardiac and extracardiac level. Results: Myocardial uptake of 99mTc-PYP was identified in the left ventricle in 6 patients and in the right ventricle in 3 patients. In these cases, the H/CL ratio was >1.5. In the rest, myocardial uptake was ruled out, with a H/CL ratio of 1.5. Vascular pool activity was detected in the tomographic images of 7 patients and abnormal extracardiac bone uptake of traumatic/degenerative causes in 9 patients. Five patients presented diffuse hepatic uptake, without structural alteration on CT. Conclusions: 99mTc-PYP is a clinically relevant technique in patients with suspected CA. It constitutes a minimally invasive tool, widely available, low cost and useful in diagnosis, and can guide the AC subtype. The information it provides also makes it possible to guide therapeutic options and provide additional prognostic information.
Introdução: a amiloidose cardíaca (AC) é uma cardiomiopatia infiltrativa causada pela deposição extracelular de amiloide no miocárdio. As variantes mais frequentes são devidas a cadeias leves de imunoglobulina ou transtirretina (ATTR). A cintilografia com 99mTc-pirofosfato (99mTc-PYP) é uma técnica de imagem molecular que permite a diferenciação dos subtipos mais comuns de QA. O presente estudo analisou o papel do 99mTc-PYP e do SPECT-CT na avaliação de pacientes com suspeita clínica de AC. Materiais e métodos: foram realizados 99mTc-PYP e SPECT-CT em 16 pacientes com suspeita clínica de QA, com idade média de 63 anos. A análise qualitativa foi realizada nas imagens planas e SPECT-CT (Mediso, AnyScan), adquiridas 1-3 horas após a injeção do radiotraçador. Para a análise quantitativa das imagens planas, foi calculada a relação H/CL (contagens médias obtidas nas regiões de interesse do coração e do hemitórax contralateral). O estudo foi considerado positivo para ATTR quando a relação H/CL era ≥1,5. As imagens SPECT-CT foram interpretadas para observar a distribuição do traçador em nível cardíaco e extracardíaco. Resultados: a captação miocárdica de 99mTc-PYP foi identificada no ventrículo esquerdo em 6 pacientes e no ventrículo direito em 3 pacientes. Nestes casos, a relação H/CL foi >1,5. Nos demais, foi descartada captação miocárdica, com relação H/CL de 1,5. Atividade do pool vascular foi detectada nas imagens tomográficas de 7 pacientes e captação óssea extracardíaca anormal de causas traumáticas/degenerativas em 9 pacientes. Cinco pacientes apresentaram captação hepática difusa, sem alteração estrutural na TC. Conclusões: o 99mTc-PYP é uma técnica clinicamente relevante em pacientes com suspeita de AC. Constitui uma ferramenta minimamente invasiva, amplamente disponível, de baixo custo e útil no diagnóstico, podendo orientar o subtipo AC. A informação que disponibiliza permite também orientar opções terapêuticas e fornecer informação prognóstica adicional.
Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Pirofosfato de Tecnecio Tc 99m , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Cardiopatías/diagnóstico por imagen , Amiloidosis/diagnóstico por imagen , Estudios RetrospectivosRESUMEN
Prostate cancer is a leading cause of cancer death in men worldwide. Imaging plays a key role in disease detection and initial staging. Emerging data has shown the superiority of PSMA imaging with PET/CT over conventional imaging for primary diagnoses. Single photon emission computed tomography is more available worldwide, and the imaging agent is low in cost. The aim of this study is to compare the diagnostic accuracy of 99mTc-EDDA/HYNIC-iPSMA SPECT/CT to 18F-PSMA-1007 PET/CT in the primary diagnosis of prostate cancer and the impact on clinical staging. METHODS: In this prospective controlled study, 18 patients with histologically confirmed prostate cancer with unfavorable intermediate-, high-, and very high-risk characteristics were recruited to undergo 18F-PSMA-PET/CT and 99mTc-iPSMA SPECT/CT. The median age of the patients was 71 years old, and the median PSA level was 23.3 ng/mL. Lesions were divided into the prostate, seminal vesicles, lymph nodes, bone, and visceral metastases. Volumetric analysis was also performed between the two imaging modalities and correlated with PSA levels. RESULTS: A total of 257 lesions were detected on 18F-PSMA-PET/CT: prostate (n = 18), seminal vesicles (n = 12), locoregional lymph nodes (n = 62), non-locoregional (n = 67), bone (n = 90), and visceral (n = 8). Of these, 99mTc-iPSMA-SPECT/CT detected 229 lesions, while both reviewers detected 100% of the lesions in the prostate (18/18), seminal vesicles (12/12), and visceral (8/8); LN LR (56/62; 90%), NLR (57/67; 85%), and bone (78/90; 86%). There were no statistically significant differences between volumetric parameters (t = -0.02122; p = 0.491596). CONCLUSIONS: 99mTc-iPSMA SPECT/CT is useful in the primary diagnosis of prostate cancer. Despite it showing a slightly lower lesion detection rate compared to 18F-PSMA PET/CT, it exhibited no impact on clinical staging and, consequently, the initial treatment intention.
RESUMEN
INTRODUCTION: Computed tomography angiography (CTA) and ventilation/perfusion (V/Q) single photon emission computed tomography/CT (SPECT/CT) images have been widely used to detect PE, but few studies have performed a direct comparison between them. We aimed to evaluate the performance of these tests in the same group of patients, selected from the routine practice of a general hospital. METHODS: Patients with suspected acute PE were prospectively submitted to CTA and V/Q SPECT/CT. General radiologists and nuclear physicians, respectively, interpreted the images. Data regarding age, sex, time between examinations, symptoms, and Wells score were also recorded. The final diagnosis was decided through a consensus among the clinicians, taking into account clinical, laboratory, follow-up, and all imaging procedures data. RESULTS: Twenty-eight patients (15 male, 13 female, and median age of 51.5 years) were studied. Median duration of the onset of symptoms was 4 (1-14) days, and the median Wells score was 3.5 (1.5-6). Sensitivity, specificity, positive and negative predictive values, and accuracy were 84.6%, 80.0%, 78.6%, 85.7%, and 82.1% for V/Q SPECT/CT, and 46.1%, 100%, 100%, 68.2%, and 75.0% for CTA. The overall agreement between the methods was 57.1%. Of the 22 patients with negative CTA, 10 (45.4%) had positives V/Q SPECT/CT and seven of them classified as true positives. CONCLUSIONS: Our results suggest that V/Q SPECT/CT is more sensitive and accurate than CTA when interpreted by general radiologists and nuclear medicine physicians.
Asunto(s)
Tomografía Computarizada Multidetector , Embolia Pulmonar , Humanos , Masculino , Femenino , Persona de Mediana Edad , Relación Ventilacion-Perfusión , Embolia Pulmonar/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único/métodos , Angiografía , Enfermedad Aguda , PerfusiónRESUMEN
Introducción: la técnica de imagen híbrida de SPECT-CT combina la imagen de la tomografía por emisión de fotón único (SPECT) con el estudio de tomografía computada (TC), obteniendo información funcional y anatómica en un mismo estudio. La dosis efectiva total de radiación ionizante recibida en los estudios SPECT-CT puede ser estimada a partir de la dosis efectiva atribuible a la actividad administrada del radiofármaco y la dosis efectiva del componente de tomografía computada (TC). Objetivos: estimar la dosis efectiva total en los protocolos SPECT-CT utilizados en población adulta y determinar el aporte adicional del estudio TC sobre la dosis efectiva total. Método: se evaluaron 258 estudios SPECT-CT para estimar la dosis efectiva total aportada por la administración de los radiofármacos y los estudios de TC de baja dosis. Para estimar el aporte de ambos componentes se utilizaron factores de conversión específicos de cada radiofármaco y región explorada mediante TC. Resultados: la dosis efectiva total (media ± DS) en los estudios SPECT-CT fueron: 12,4 ± 1,44 mSv en el estudio de perfusión miocárdica, 1,14 ± 0,25 mSv en ganglio centinela de mama, 8,6 ± 0,6 mSv paratiroides, 1,48 ± 1,02 mSv tiroides y los estudios óseos de las regiones de cuello 4,5 ± 0,3, tórax 6,07 ± 0,3 mSv, abdomen y pelvis 6,1 ± 0,3 mSv. La dosis de radiación aportada por el estudio TC se encuentra entre 0,46 mSv para la región del tórax en el estudio de ganglio centinela de mama y 2,3 mSv para el SPECT-CT óseo en la región de abdomen y pelvis. Conclusión: se logró estimar la dosis efectiva en los protocolos SPECT-CT de uso clínico más frecuente en población adulta y el aporte de los estudios TC a la dosis efectiva total siendo relativamente baja comparado con la dosis aportada por los radiofármacos administrados con la excepción del estudio de ganglio centinela donde la contribución del componente TC es aproximadamente la mitad de la dosis efectiva total.
Introduction: SPECT-CT Hybrid image technique combines the SPECT (single-photon emission computed tomography) image with the CT (computerized tomography) image to obtain both functional and anatomical images in the same study. The total effective ionizing radiation dose received in SPECT-CT studies may be estimated based on the effective dose from the radiopharmaceutical administered and the effective dose from the CT (computerized tomography) component. Objectives: the study aims to estimate the total effective dose in SPECT-CT protocols applied for the adult population, and to determine the additional contribution from the CT component to the total effective dose. Method: 258 SPECT-CT studies were evaluated to estimate the total effective dose from the administration of radiopharmaceuticals and low dose CT studies. Specific conversion factors for each radiopharmaceutical and area of the body explored with the CT were used to estimate radiation doses from both components. Results: total effective dose (average ± SD) in the SPECT-CT studies was: 12.4 ± 1.44 mSv in the myocardial perfusion study, 1.14 ± 0.25 mSv in the breast sentinel lymph node study, 8.6 ± 0.6 mSv in the parathyroid study, 1.48 ± 1.02 mSv in the thyroid study. As to bone studies, doses found were: 4.5 ± 0.3, in neck studies, 6.07 ± 0.3 mSv in thoracic studies and 6.1 ± 0.3 mSv in abdominal and pelvic studies. The radiation dose from the CT study ranges from 0.46 mSv for the thoracic region on the breast sentinel lymph node study to 2.3 mSv for the bone SPECT-CT study of the abdominal and pelvic region. Conclusions: we managed to estimate the effective dose in the the most frequently used SPECT-CT protocols for the adult population and the contribution of CT studies to the total effective dose. It was found to be relatively low when compared to the dose contributed by the radiopharmaceuticals administered, with the exception of the sentinel lymph node study for which the contribution from the CT study is approximately half the total effective dose.
Introdução: a técnica de imagem híbrida SPECT-CT combina a imagem de tomografia por emissão de fóton único (SPECT) com o estudo de tomografia computadorizada (TC), obtendo informações funcionais e anatômicas no mesmo estudo. A dose efetiva total de radiação ionizante recebida em estudos SPECT-CT pode ser estimada a partir da dose efetiva atribuível à atividade administrada do radiofármaco e da dose efetiva do componente de tomografia computadorizada (TC). Objetivos: estimar a dose efetiva total nos protocolos SPECT-CT utilizados na população adulta e determinar a contribuição adicional do estudo de TC na dose efetiva total. Método : 258 estudos SPECT-CT foram avaliados para estimar a dose efetiva total fornecida pela administração de radiofármacos e estudos de TC de baixa dose. Para estimar a contribuição de ambos os componentes, foram utilizados fatores de conversão específicos para cada radiofármaco e região explorada pela TC. â Resultados: a dose efetiva total (média ± DP) nos estudos SPECT-CT foi: 12,4 ± 1,44 mSv no estudo de perfusão miocárdica, 1,14 ± 0,25 mSv no linfonodo sentinela mamário, 8,6 ± 0,6 mSv paratireoide, 1,48 ± 1,02 mSv estudos de tireoide e ossos das regiões do pescoço 4,5 ± 0,3, tórax 6,07 ± 0,3 mSv, abdômen e pelve 6,1 ±0,3mSv. A dose de radiação fornecida pelo estudo de TC está entre 0,46 mSv para a região do tórax no estudo do linfonodo sentinela da mama e 2,3 mSv para o SPECT-CT ósseo na região do abdome e pelve. Conclusão: foi possível estimar a dose efetiva nos protocolos de SPECT-CT mais utilizados clinicamente na população adulta e a contribuição dos estudos de TC para a dose efetiva total, sendo relativamente baixa em relação à dose fornecida pelos radiofármacos administrados com a exceção do estudo do linfonodo sentinela onde a contribuição do componente TC é aproximadamente metade da dose efetiva total.
Asunto(s)
Protección Radiológica/normas , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/normas , Guías como Asunto , Medicina NuclearRESUMEN
CONTEXT: Normocalcemic primary hyperparathyroidism (nPHPT) is defined by an inappropriately increased serum PTH with normal serum calcium. Information about the diagnostic yield of parathyroid SPECT/CT scan and ultrasonography in nHPPT is limited and not conclusive. PURPOSE: To evaluate the positivity rate of 99m Tc-Sestamibi SPECT/CT scan in nPHTP compared with classical hypercalcemic PHPT (cPHPT). MATERIALS AND METHODS: We retrospectively studied 125 patients with 99m Tc-Sestamibi SPECT/CT scans. Subjects were divided into 2 groups: cPHPT (n = 93) and nPHPT (n = 32). RESULTS: The detection rate of 99m Tc-Sestamibi SPECT/CT in cPHPT was 86,02% (80/93) and 59.37%, in nPHPT (19/32), p = .003. No significant differences were seen between the SPECT/CT scan and ultrasonography (p = .28) and the agreement was higher in cPHPT than in nPHPT, p = .03. Sensitivity of 99m Tc-Sestamibi-SPECT/CT was 98% on a per-patient basis (PPV 96%) and 91% on a per-lesion basis (PPV 88%). Glandular size was smaller in nPHPT (mean value 6.8 mm) and it was related only with PTH value. CONCLUSION: Localization rate of parathyroid hyperfunctioning tissue with 99m Tc-Sestamibi SPECT/CT is lower in nPHPT and it is related to a smaller glandular size. However, our study suggests that the positivity rate and sensitivity are nonnegligible by adding SPECT/CT. The reduction in the detection rate in nPHPT could benefit techniques with higher resolution such as 18 F-Choline PET/CT when the clinical context justifies it.
Asunto(s)
Hipercalcemia , Hiperparatiroidismo Primario , Humanos , Hiperparatiroidismo Primario/diagnóstico por imagen , Glándulas Paratiroides/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Estudios Retrospectivos , Tecnecio Tc 99m Sestamibi , Tomografía Computarizada de Emisión de Fotón ÚnicoRESUMEN
Celiac disease (CD) is an immune-mediated systemic disorder triggered by gluten and related prolamins in genetically predisposed individuals. Here, we described a case of a 31-year-old Caucasian woman who exhibited cerebellar and psychiatric dysfunctions. The patient underwent single-photon emission computed tomography (SPECT-CT) before and after a gluten-free diet (GFD). There was an improvement in cerebellar perfusion accompanied by a remission of cerebellar manifestations. The maintenance of the psychiatric manifestations was related to the persistence of the hypoperfusion in the frontal lobes. The patient's psychiatric symptoms did not change after 4 months under a GFD in the hospital. To our knowledge, this is the first case that shows the relationship between improvement in cerebellar perfusion and remission of cerebellar clinical manifestations in a CD patient under a GFD.
Asunto(s)
Enfermedad Celíaca , Ataxia Cerebelosa , Adulto , Enfermedad Celíaca/complicaciones , Enfermedad Celíaca/diagnóstico por imagen , Ataxia Cerebelosa/complicaciones , Ataxia Cerebelosa/diagnóstico por imagen , Dieta Sin Gluten , Femenino , Humanos , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos XRESUMEN
Chronic Chagas' cardiomyopathy is the most severe and frequent manifestation of Chagas disease, and has a high social and economic burden. New imaging modalities, such as strain echocardiography, nuclear medicine, computed tomography and cardiac magnetic resonance imaging, may detect the presence of myocardial fibrosis, inflammation or sympathetic denervation, three conditions associated with risk of sudden death, providing additional diagnostic and/or prognostic information. Unfortunately, despite its high mortality, there is no clear recommendation for early cardioverter-defibrillator implantation in patients with Chagas heart disease in the current guidelines. Ideally, the risk of sudden cardiac death may be evaluated in earlier stages of the disease using new image methods to allow the implementation of primary preventive strategies.
RESUMEN
Objetivo El objetivo del presente trabajo es evaluar el valor adicional del spect/ct sobre el Centellograma de Cuerpo Entero (cce) y la spect en pacientes con cáncer de mama con mínimo dos estudios: tiempo inicial (i) y evolución (e). Material y método Se evaluaron retrospectivamente 208 lesiones en 186 pacientes. Se realizaron imágenes: cce, spect y spect/ct del esqueleto axial con 99mTcmdp y equipo híbrido Infinia Hawkeye 4 GE. Las lesiones se caracterizaron del siguiente modo: benigna (b); maligna (m); y equívocas: probablemente benigna (pb) y probablemente maligna (pm). Resultados spect/cti clasificó 197/208 lesiones (94,7%), specti 155/208 (74,5%) y ccei 130/208 (51%). Los tres métodos coincidieron inicialmente en 138 lesiones: 106 b (77%), 23 m (17%) y 9 equívocas (6%), y en la evolución en 155: 110 b (71%), 44 m (28%), 1 equívoca (1%). La sensibilidad, especificidad y exactitud inicial para diagnóstico de metástasis (incluyendo como malignas las lesiones probablemente malignas) fueron 92/70/51% (ccei), 100/78/75% (specti) y 100/97/95% (spect/cti). Diferencias de a pares: ccei vs specti y spect/cti para sensibilidad (p<0,05) y specti y ccei vs spect/cti especificidad y exactitud (p<0,001). Conclusiones El aporte de spect/ct incrementó la precisión y certeza diagnóstica para diferenciar las lesiones benignas, malignas y equívocas. Su utilización debería ser rutinaria en la detección de metástasis óseas en pacientes con carcinoma de mama
Objective To assess the additional value of spect/ct on whole-body scintigraphy (wbs) and spect in patients with breast cancer, with a minimum of two tests: start time (i) and assessment (e). Materials and method Retrospective assessment of 208 lesions in 186 patients. Images were taken by wbs, spect and spect/ct of the axial skeleton with 99mTc- mdp and hybrid equipment Infinia Hawkeye 4 GE. Characterization of the lesions: benign (b), malignant (m) and equivocal: likely to be benign or malignant. Results By using spect/cti, 197/208 lesions (94.7%), specti 155/208 (74.5%) and wbsi 130/208 (51%) were classified. The three methods initially coincided on 138 lesions: 106 b (77%), 23 m (17%) and 9 equivocal (6%); and on assessment on 155: 110 b (71%), 44 m (28%), 1 equivocal (1%). The initial sensitivity, specificity and accuracy for the diagnosis of metastases (including as malignant those lesions which were likely to be so) were as follows: 92/70/51% (wbsi), 100/78/75% (specti) and 100/97/95% (spect/cti). Differences by pairs: wbsi vs specti and spect/cti for sensitivity (p<0,05) and specti and wbsi vs spect/cti for specificity and accuracy (p<0,001). On assessment 99%. Conclusions The contribution of spect/ct has increased diagnostic accuracy and certainty to differentiate benign, malignant and equivocal lesions. It should be used routinely for the detection of bone metastases in patients with breast cancer
Asunto(s)
Neoplasias de la Mama , Tomografía Computarizada de Emisión de Fotón Único , Metástasis de la NeoplasiaRESUMEN
Gait and postural control deficiencies in Parkinson's disease (PD) involve several specific motor aspects. The aim of this study was to identify and compare the main changes in gait kinematics and postural control with dopaminergic loss in the striatum region. This is a cross-sectional study that included 42 individuals with PD at different motor stages, according to the Hoehn & Yahr scale (H&Y). Motor subsection of the Movement Disorder Society-Unified Parkinson Disease Rating Scale-part III (MDS-UPDRS III) was used to evaluate general motor aspects. Gait kinematics was assessed using a three-dimensional motion capture system. Postural control was assessed by stabilometry using force platforms. Dopamine depletion was verified through 99mTc-TRODAT-1 (SPECT-CT) examination. We included 12, 15 and 15 individuals classified as H&Y I, II and III, respectively. We identified worse values of dopamine transporter uptake, MDS-UPDRS III, gait parameters (velocity, step length and stride length) and center of pressure displacement as the disease progressed. Our results indicate that higher dopaminergic loss and gait and postural control deficits occur between the H&Y levels II and III.
Asunto(s)
Trastornos Neurológicos de la Marcha/fisiopatología , Marcha/fisiología , Enfermedad de Parkinson/fisiopatología , Equilibrio Postural/fisiología , Estudios Transversales , Dopamina/metabolismo , Proteínas de Transporte de Dopamina a través de la Membrana Plasmática/metabolismo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad de Parkinson/complicacionesRESUMEN
Parkinson's disease (PD) is a progressive neurodegenerative disorder caused by the loss of dopamine, an important neurotransmitter involved in regulating movement. Nuclear medicine imaging methods such as single-photon emission computed tomography (SPECT) combined with radiotracers can obtain the density of this neurotransmitter. This reduced density leads to classic PD symptoms, such as bradykinesia, tremor and stiffness, consequently affecting walking and postural control. The aim of this study was to verify the correlation between disorders of gait kinematics and postural instability with dopamine depletion in individuals with mild to moderate PD. This is a descriptive, observational cross-sectional study. Subjects were assessed for spatiotemporal gait parameters by a three-dimensional motion capture system, for postural control by stabilometry on a force plate. Dopamine depletion was verified through 99mTc-TRODAT-1 (SPECT-CT) examination. The subjects were in the off-stage of levodopa in all analysis. We evaluated 71 individuals, 32 with mild to moderate PD (HY 2 and 2.5) and 39 healthy individuals matched for gender, age, and height. There was a significant difference between the groups regarding the spatiotemporal variables of gait, as well as in the stabilometric variables. However, there was no correlation between these disturbances and the uptake values of 99mTc-TRODAT-1. The results indicate that there is no correlation between gait impairments and postural instability of individuals with mild to moderate PD and the dopaminergic depletion measured through the 99mTc-TRODAT-1 (SPECT-CT).
Asunto(s)
Encéfalo/metabolismo , Proteínas de Transporte de Dopamina a través de la Membrana Plasmática/metabolismo , Marcha/fisiología , Enfermedad de Parkinson/fisiopatología , Equilibrio Postural/fisiología , Fenómenos Biomecánicos , Encéfalo/diagnóstico por imagen , Estudios Transversales , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Enfermedad de Parkinson/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Análisis Espacio-Temporal , Tomografía Computarizada de Emisión de Fotón ÚnicoRESUMEN
Positron emission tomography (PET) with prostate-specific membrane antigen (PSMA) has found widespread use for the diagnosis of biochemical recurrence of prostate cancer (PCa). Unfortunately, PET/CT is not as widely available; thus a PSMA-targeting compound for scintigraphy is of special interest. The aim of this study was to compare 99mTc-EDDA/HYNIC-iPSMA and 68Ga-PSMA-11 PET/CT qualitatively and semi-quantitatively. Twenty-three patients with metastatic PCa were underwent 99mTc-EDDA/HYNIC-iPSMA SPECT/CT followed by 68Ga-PSMA-11 PET/CT. Gleason score in all patients was obtained. Maximal standardized uptake value (SUVmax) and counts per organ, including the primary and metastatic tumor, were normalized and compared using Pearson's correlation test. Sites considered as positive have increased SUVmax and tumor-to-background ratio (TBR) in comparison with non-diseased organs/tissues (SUVmax =25.2±4.7, 18.4±1.6, 11.4±1.2 (P=0.037) from prostate, bone and lymph nodes versus TBR =35.9±45.2, 15.4±18.9, 19.1±51.7 (P=0.035) for prostate, bone and lymph nodes. 99mTc-HYNIC-iPSMA and 68Ga-PSMA-11 uptake values in the evaluation of the affected nodes were very similar, although their ranges ranged from 5-21 mm (12±7.6). Correlation coefficient was normalized between SUVmax and TBR, demonstrating r values for prostate of r2=0.731; for bone of r2=0.720; and lymph nodes of r2=0.864 (P<0.05 in all cases). Values and confidence interval at the 95% are supporting the equivalency of both parameters in primary tumor and metastases (prostate 95% CI=4.61, 4.38; bone tissue 95% CI=-2.21, 3.41 and lymph node 95% CI=4.67). We conclude that 68Ga-PSMA-11 PET/CT and 99mTc-EDDA/HYNIC-iPSMA SPECT/CT were comparable, supporting the use of 99mTc-EDDA/HYNIC-iPSMA in patients with progressive metastatic castration-resistant PCa.
RESUMEN
Background: Imaging studies, particularly simple and contrast-enhanced tomography, constitute the first diagnostic approach to detect recurrence of musculoskeletal tumors. The aim of the present retrospective study was to demonstrate the usefulness of scintigraphy plus SPECT/CT (single photon emission computed tomography) with thallium-201 (201Tl) in the evaluation of malignant musculoskeletal tumors with suspicion of recurrence or metastatic disease. Methods: Eight weeks after the last therapy, 72 scintigraphy and SPECT/CT studies were performed to assess regional recurrence and metastatic disease in 42 patients with different types of malignant musculoskeletal tumors, such as osteosarcoma, Ewing's sarcoma, rhabdomyosarcoma, retinoblastoma, synovial sarcoma, and Wilms tumor at the Hospital Infantil de México Federico Gómez. The positive predictive value (PPV) and the confidence interval of the scintigraphy and SPECT/CT were calculated when compared with the results of the histopathological analysis and the clinical and radiological follow-up for the identification of recurrence. Results: Scintigraphy was abnormal in 30 (71.4%) of the 42 patients; 33 lesions (30 patients) were detected by scintigraphy and 25 lesions (21 patients) by chest X-ray and tomography of two regions. The SPECT/CT was performed on 30 patients, where 12 lesions were detected in addition to the planar scintigraphy. Scintigraphy showed a PPV of 82%; SPECT/CT, 100%. Conclusion: 201Tl-scintigraphy can be considered as an adequate study to identify the sites of tumor viability with a high degree of diagnostic certainty combined with the SPECT/CT technique.
Introducción: Los estudios de imagen, como la tomografía simple y contrastada, son la primera aproximación diagnóstica para detectar la recurrencia de tumores musculoesqueléticos. El objetivo de este estudio retrospectivo fue demostrar la utilidad de la gammagrafía acoplada a tomografía computarizada por emisión de fotón único (SPECT/CT) con talio-201(201Tl) en la valoración de tumores musculoesqueléticos malignos con sospecha de recurrencia o enfermedad metastásica. Métodos: Se realizaron 72 estudios gammagráficos y de SPECT/CT para la valoración de la recurrencia locorregional y a distancia, al menos 8 semanas tras la última terapia, en 42 pacientes con diferentes tipos de tumores musculoesqueléticos malignos, como osteosarcoma, sarcoma de Ewing, rabdomiosarcoma, retinoblastoma, sarcoma sinovial y tumor de Wilms en el Hospital Infantil de México. Se calcularon el valor predictivo positivo (VPP) y el intervalo de confianza del gammagrama y de la SPECT/CT en comparación con el resultado del análisis histopatológico y el seguimiento clínico y radiológico para identificar la recurrencia. Resultados: La gammagrafía fue anormal en 30 (71.4%) de los 42 pacientes. Se detectaron 33 lesiones (30 pacientes) por gammagrafía y 25 (21 pacientes) por telerradiografía de tórax y tomografía de dos regiones. La SPECT/CT se realizó en 30 pacientes y se detectaron 2 lesiones adicionales al rastreo planar. El VPP con la gammagrafía fue del 82%, y con la SPECT/CT, del 100%. Conclusión: La gammagrafía con 201Tl puede considerarse un estudio adecuado para identificar los sitios de viabilidad tumoral, con alto grado de certeza diagnóstica al complementar con SPECT/CT.
Asunto(s)
Neoplasias Óseas/diagnóstico por imagen , Neoplasias de los Músculos/diagnóstico por imagen , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Adolescente , Neoplasias Óseas/patología , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Masculino , México , Neoplasias de los Músculos/patología , Recurrencia Local de Neoplasia , Valor Predictivo de las Pruebas , Cintigrafía/métodos , Estudios Retrospectivos , Radioisótopos de Talio/administración & dosificaciónRESUMEN
Resumen Introducción: Los estudios de imagen, como la tomografía simple y contrastada, son la primera aproximación diagnóstica para detectar la recurrencia de tumores musculoesqueléticos. El objetivo de este estudio retrospectivo fue demostrar la utilidad de la gammagrafía acoplada a tomografía computarizada por emisión de fotón único (SPECT/CT) con talio-201(201Tl) en la valoración de tumores musculoesqueléticos malignos con sospecha de recurrencia o enfermedad metastásica. Métodos: Se realizaron 72 estudios gammagráficos y de SPECT/CT para la valoración de la recurrencia locorregional y a distancia, al menos 8 semanas tras la última terapia, en 42 pacientes con diferentes tipos de tumores musculoesqueléticos malignos, como osteosarcoma, sarcoma de Ewing, rabdomiosarcoma, retinoblastoma, sarcoma sinovial y tumor de Wilms en el Hospital Infantil de México. Se calcularon el valor predictivo positivo (VPP) y el intervalo de confianza del gammagrama y de la SPECT/CT en comparación con el resultado del análisis histopatológico y el seguimiento clínico y radiológico para identificar la recurrencia. Resultados: La gammagrafía fue anormal en 30 (71.4%) de los 42 pacientes. Se detectaron 33 lesiones (30 pacientes) por gammagrafía y 25 (21 pacientes) por telerradiografía de tórax y tomografía de dos regiones. La SPECT/CT se realizó en 30 pacientes y se detectaron 12 lesiones adicionales al rastreo planar. El VPP con la gammagrafía fue del 82%, y con la SPECT/CT, del 100%. Conclusión: La gammagrafía con 201Tl puede considerarse un estudio adecuado para identificar los sitios de viabilidad tumoral, con alto grado de certeza diagnóstica al complementar con SPECT/CT.
Abstract Background: Imaging studies, particularly simple and contrast-enhanced tomography, constitute the first diagnostic approach to detect recurrence of musculoskeletal tumors. The aim of the present retrospective study was to demonstrate the usefulness of scintigraphy plus SPECT/CT (single photon emission computed tomography) with thallium-201 (201Tl) in the evaluation of malignant musculoskeletal tumors with suspicion of recurrence or metastatic disease. Methods: Eight weeks after the last therapy, 72 scintigraphy and SPECT/CT studies were performed to assess regional recurrence and metastatic disease in 42 patients with different types of malignant musculoskeletal tumors, such as osteosarcoma, Ewing's sarcoma, rhabdomyosarcoma, retinoblastoma, synovial sarcoma, and Wilms tumor at the Hospital Infantil de México Federico Gómez. The positive predictive value (PPV) and the confidence interval of the scintigraphy and SPECT/CT were calculated when compared with the results of the histopathological analysis and the clinical and radiological follow-up for the identification of recurrence. Results: Scintigraphy was abnormal in 30 (71.4%) of the 42 patients; 33 lesions (30 patients) were detected by scintigraphy and 25 lesions (21 patients) by chest X-ray and tomography of two regions. The SPECT/CT was performed on 30 patients, where 12 lesions were detected in addition to the planar scintigraphy. Scintigraphy showed a PPV of 82%; SPECT/CT, 100%. Conclusion: 201Tl-scintigraphy can be considered as an adequate study to identify the sites of tumor viability with a high degree of diagnostic certainty combined with the SPECT/CT technique.
Asunto(s)
Adolescente , Niño , Preescolar , Femenino , Humanos , Masculino , Neoplasias Óseas/diagnóstico por imagen , Neoplasias de los Músculos/diagnóstico por imagen , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Neoplasias Óseas/patología , Radioisótopos de Talio/administración & dosificación , Cintigrafía/métodos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Estudios de Seguimiento , Neoplasias de los Músculos/patología , México , Recurrencia Local de NeoplasiaRESUMEN
Resumen El cáncer de tiroides es una enfermedad cada vez más frecuente. Uno de los factores que contribuye, es el uso de las imágenes de radiología para evaluar dolencias del área de cabeza y cuello. Una vez se completa el manejo, se continúa con el seguimiento usando la tiroglobulina y los anticuerpos tiroideos tiroglobulínicos, acompañados de ecografía de alta resolución. Esta puede detectar recaídas de escasos milímetros que no son palpables, y que en zonas ya operadas son difíciles de resecar. La técnica ROLL (radioguided occult lesion localization) ha sido usada en los últimos años con gran éxito en estos casos. Para optimizar la cirugía radioguiada en cáncer tiroideo recurrente, aplicamos la ventaja que tienen los estudios tomográficos en medicina nuclear denominados SPECT/CT (single photon emision tomography, por su sigla en inglés) fusionados con técnicas de imágenes anatómicas de tomografía (CT) para refinar la localización anatómica precisa de las lesiones radiomarcadas.
Abstract Differentiated thyroid cancer is an increasingly diagnosed disease. One of the contributing factors is the routine use of high-resolution imaging techniques to assess patients with head and neck symptoms. Serum thyroglobulin monitoring and neck ultrasound are the cornerstone of early detection of recurrent disease after surgery and radioiodine remnant ablation. Resection of non-palpable small tumour foci in previously operated sites is difficult. In recent years, the use of a radioguided technique for locating lesions (ROLL) has shown to be useful for optimising recurrent thyroid cancer surgery. SPECT/CT has also been added to refine the anatomical location of the radio-marked tumour foci.
Asunto(s)
Humanos , Neoplasias de la Tiroides , Tomografía Computarizada de Emisión de Fotón Único , Cuello , Tomografía , Ultrasonografía , Métodos , Biopsia del Ganglio Linfático CentinelaRESUMEN
OBJECTIVE: The aim of this study was to assess the occurrence and frequency of increased physiologic uptake of 99mTc-HYNIC-TOC by the uncinate process of the pancreas in SPECT/CT images. METHODS: Forty-six scans of 41 patients were evaluated retrospectively. The uptake of 99mTc-HYNIC-TOC was considered to be physiologic in patients with normal findings at dedicated abdominal CT or MR and lack of neoplastic lesions in clinical follow-ups. The intensity of uncinate process uptake was compared to the uptake of the normal liver. RESULTS: Focal uptake was attributed to the presence of pancreatic NET in 5 patients. Among the 36 patients without any evidence of malignancy in CT, MR and follow-up, 7 (19.4 %) showed increased uptake in the uncinate process. The intensity of uptake was lesser in 3 (8.3 %), similar in 3 and greater than the normal liver in 1 (2.8 %) case. CONCLUSION: Increased 99mTc-HYNIC-TOC uptake occurred in 19.4 % of those subjects without any evidence of neuroendocrine tumor in the uncinate process.
Asunto(s)
Imagen Multimodal , Octreótido/análogos & derivados , Compuestos de Organotecnecio/farmacocinética , Páncreas/metabolismo , Radiofármacos/farmacocinética , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Hígado/metabolismo , Masculino , Persona de Mediana Edad , Tumores Neuroendocrinos/diagnóstico , Octreótido/farmacocinética , Receptores de Somatostatina , Estudios RetrospectivosRESUMEN
INTRODUCTION: SPECT-CT in the detection of the sentinel lymph node (SLN) of breast cancer offers known advantages over conventional planar lymphoscintigraphy. Sometimes, it shows atypical findings like mediastinal lymphatic drainage. We have evaluated these atypical findings showed by SPECT-CT performed in patients with migration to the internal mammary chain (IMC) and their roles in the management of the patients. MATERIALS AND METHODS: We reviewed the 56 lymphoscintigraphies (planar and SPECT-CT) of 56 women (average age: 55 years) diagnosed with breast cancer with IMC migration observed in the planar images. We compared the two techniques, obtaining the number of depicted nodes, atypical locations, their exact anatomical location and their role in the management of the patient. RESULTS: Planar images showed a total number of 81 IMC nodes. SPECT-CT showed 74 nodes in the IMC territory and 14 mediastinal lymphatic nodes in 6 patients. Out of the 81 IMC nodes reported by planar images, seven corresponded to mediastinal nodes. Planar and hybrid images showed 110 and 130 axillary nodes, respectively. SPECT-CT showed additional findings in five patients: three infraclavicular and two supraclavicular nodes that were exactly located. One intramammary node was discarded by the SPECT-CT as a focal skin contamination. CONCLUSION: Mediastinal nodes are unexpected, but not uncommon findings that are important in the planning of SLN biopsy. SPECT-CT found more nodes than planar images, being able to separate mediastinal and IMC nodes, helping to exactly depict the SLN and its relations with anatomical structures.
Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Drenaje/métodos , Ganglios Linfáticos/diagnóstico por imagen , Linfocintigrafia/métodos , Biopsia del Ganglio Linfático Centinela/métodos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Femenino , Estudios de Seguimiento , Humanos , Ganglios Linfáticos/patología , Ganglios Linfáticos/cirugía , Persona de Mediana Edad , Estadificación de Neoplasias , PronósticoRESUMEN
UNLABELLED: There are different metabolic imaging methods, various tracers, and emerging anatomic modalities to stage neuroendocrine tumor (NET). We aimed to compare NET lesion detectability among (99m)Tc-hydrazinonicotinamide (HYNIC)-octreotide (somatostatin receptor scintigraphy [SSRS]) SPECT/CT, (68)Ga-DOTATATE PET/CT, and whole-body diffusion-weighted MR imaging (WB DWI). METHODS: Nineteen consecutive patients (34-77 y old; mean, 54.3 ± 10.4 y old; 10 men and 9 women) underwent SSRS SPECT/CT, (68)Ga-DOTATATE PET/CT, and WB DWI. Images were acquired with a maximum interval of 3 mo between them and were analyzed with masking by separate teams. Planar whole-body imaging and SPECT/CT were performed from thorax to pelvis using a double-head 16-slice SPECT/CT scanner 4 h after injection of 111-185 MBq of (99m)Tc-HYNIC-octreotide. (68)Ga-DOTATATE PET/CT was performed from head to feet using a 16-slice PET/CT scanner 45 min after injection of 185 MBq of tracer. WB DWI was performed in the coronal plane using a 1.5-T scanner and a body coil. The standard method of reference for evaluation of image performance was undertaken: consensus among investigators at the end of the study, clinical and imaging follow-up, and biopsy of suggestive lesions. RESULTS: McNemar testing was applied to evaluate the detectability of lesions using (68)Ga-DOTATATE PET/CT in comparison to SSRS SPECT/CT and WB DWI: a significant difference in detectability was noted for pancreas (P = 0.0455 and P = 0.0455, respectively), gastrointestinal tract (P = 0.0455 and P = 0.0455), and bones (P = 0.0082 and P = 0.0082). Two unknown primary lesions were identified solely by (68)Ga-DOTATATE PET/CT. (68)Ga-DOTATATE PET/CT, SSRS SPECT/CT, and WB DWI demonstrated, respectively, sensitivities of 0.96, 0.60, and 0.72; specificities of 0.97, 0.99, and 1.00; positive predictive values of 0.94, 0.96, and 1.00; negative predictive values of 0.98, 0.83, and 0.88; and accuracies of 0.97, 0.86, and 0.91. CONCLUSION: (68)Ga PET/CT seems to be more sensitive for detection of well-differentiated NET lesions, especially for bone and unknown primary lesions. NET can be staged with (68)Ga-DOTATATE PET/CT. WB DWI is an efficient new method with high accuracy and without ionizing radiation exposure. SSRS SPECT/CT should be used only when (68)Ga-DOTATATE PET/CT and WB DWI are not available.
Asunto(s)
Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/patología , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Imagen de Cuerpo Entero/métodos , Adulto , Anciano , Algoritmos , Biopsia , Femenino , Humanos , Hidrazinas , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Ácidos Nicotínicos , Octreótido , Compuestos Organometálicos , Estudios Prospectivos , Tecnecio , Tomografía Computarizada de Emisión de Fotón Único/métodosRESUMEN
Objective : The aim of this study was to explore the clinical characteristics of renal metastatic cancer, the methods for its detection by radioiodine (131I), and the response to 131I treatment in fourteen patients with renal metastases from differentiated thyroid carcinoma (DTC).Subjects and methods : DTC patients (n = 2,955) that received treatment with 131I were retrospectively analyzed. Scans (131I-WBS, 31I-SPECT/CT and/or 18F-FDG-PET/CT) were performed after an oral therapeutic dose of 131I. Therapeutic efficacy was evaluated based on changes in Tg and anatomical imaging changes at renal lesions.Results : Among these 14 patients, 11 had avidity for 131I, but three patients did not accumulate 131I after 131I treatment. In the 11 131I-positive renal lesions, 10 cases were detected by 131I-SPECT/CT combined with another imaging modality and one case by 131I-WBS combined with ultrasonography (US). In the three 131I-negative renal lesions, two cases were detected by 18F-FDG-PET/CT and one case by computed tomography (CT). In 11 patients with 131I-avid renal metastases, Serum Tg levels in 81.82% (9/11) patients showed a gradual decline, and 18.18% (2/11) of the patients showed a significant elevation. There was no marked difference in serum Tg before the last 131I treatment (Z = 0.157; p = 0.875). Only one patient presented partial response, eight patients exhibited stable disease, and renal metastases progressed in two patients showing progressive disease. No patients reached complete response.Conclusion : 131I-SPECT/CT, combined with another imaging modality after 131I-WBS, can contribute to the early detection of renal metastases of DTC. 131I therapy is a feasible and effective treatment for most DTC renal metastases with avidity for 131I. Arq Bras Endocrinol Metab. 2014;58(3):260-9.
Objetivo : O objetivo deste estudo foi analisar as características clínicas de metástases renais, os métodos para sua detecção por radioiodo (131I) e a resposta ao tratamento com 131I em 14 pacientes com metástases renais de carcinoma diferenciado da tireoide (DTC).Sujeitos e métodos Pacientes com DTC (n = 2.955) que receberam tratamento com 131I foram analisados retrospectivamente. 131I-PCI, 31I-SPECT/CT e/ou 18F-FDG-PET/CT foram feitos após uma dose terapêutica oral de 131I. A eficácia terapêutica foi baseada nas alterações da Tg e nas imagens anatômicas das lesões renais.Resultados : Dos 14 pacientes, 11 apresentaram lesões ávidas por 131I, mas três pacientes não acumularam 131I depois do tratamento com 131I. Nas 11 lesões renais positivas para 131I, 10 casos foram detectados por 131I-SPECT/CT combinado com outra modalidade de exame de imagem e um caso por 131I-WBS combinado com US. Nas três lesões renais negativas para 131I, dois casos foram detectados por 18F-FDG-PET/CT e um caso por tomografia computadorizada (TC). Em 11 pacientes com metástases renais ávidas por 131I, os níveis séricos de Tg em 81,82% (9/11) dos pacientes mostraram um declínio gradual e 18,18% (2/11) apresentaram uma elevação significativa. Não houve diferenças marcadas na Tg sérica antes do último tratamento com 131I (Z = 0,157; p = 0,875). Apenas um paciente apresentou resposta parcial, oito pacientes apresentaram doença estável e as metástases renais progrediram em dois pacientes que apresentaram doença progressiva. Nenhum dos pacientes apresentou resposta completa.Conclusão : 131I-SPECT/CT, combinada com outra modalidade de diagnóstico por imagem após 131I-PCI, pode contribuir para a detecção precoce de metástases renais de DTC. O tratamento ...