Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Biosens Bioelectron ; 252: 116149, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38394701

RESUMEN

The microRNA-21 is closely related to chromatin remodeling and epigenetic regulation. In this work, an efficient double-response 3D DNA nanomachine (DRDN) was assembled by co-immobilizing two different lengths of hairpin DNA on the surface of gold nanoparticles (AuNPs) to capture microRNA-21 (miRNA-21), recycle miRNA-21, and trigger hybridization chain reactions (HCR). This work reports the fabrication of a laser-scribed graphene (LSG) electrode with excellent flexibility and electrical conductivity by laser-scribing commercial polyimide films (PI). The as-proposed self-powered biosensing platform presents significantly increased instantaneous current to in real-time monitor miRNA-21 by a capacitor. The biosensing platform exhibited highly sensitive detection of miRNA-21 with a detection limit of 0.142 fM in the range of 0.5 fM to 1 × 104 fM, and demonstrated high efficiency in the analysis of the tumor markers.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , MicroARNs , MicroARNs/genética , MicroARNs/análisis , Oro , Epigénesis Genética , Técnicas Electroquímicas , ADN/genética , Límite de Detección
2.
Sensors (Basel) ; 23(24)2023 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-38139647

RESUMEN

Fencing, a sport emphasizing the equilibrium and movement control of participants, forms the focal point of inquiry in the current study. The research endeavors to assess the efficacy of a novel system designed for real-time monitoring of fencers' balance and movement control, augmented by modules incorporating visual feedback and haptic feedback, to ascertain its potential for performance enhancement. Over a span of five weeks, three distinct groups, each comprising ten fencers, underwent specific training: a control group, a cohort utilizing the system with a visual real-time feedback module, and a cohort using the system with a haptic real-time feedback module. Positive outcomes were observed across all three groups, a typical occurrence following a 5-week training regimen. However, noteworthy advancements were particularly discerned in the second group, reaching approximately 15%. In contrast, the improvements in the remaining two groups were below 5%. Statistical analyses employing the Wilcoxon signed-rank test for repeated measures were applied to assess the significance of the results. Significance was solely ascertained for the second group, underscoring the efficacy of the system integrated with visual real-time feedback in yielding statistically noteworthy performance enhancements.


Asunto(s)
Deportes , Humanos , Retroalimentación , Movimiento
3.
Sensors (Basel) ; 23(13)2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37447965

RESUMEN

This paper presents a personalized and smart flowerpot for ornamental horticulture, integrating 3D printing and cloud technology to address existing design limitations and enable real-time monitoring of environmental parameters in plant cultivation. While 3D printing and cloud technology have seen widespread adoption across industries, their combined application in agriculture, particularly in ornamental horticulture, remains relatively unexplored. To bridge this gap, we developed a flowerpot that maximizes space utilization, simplicity, personalization, and aesthetic appeal. The shell was fabricated using fused deposition modeling (FDM) in 3D printing, and an Arduino-based control framework with sensors was implemented to monitor critical growth factors such as soil moisture, temperature, humidity, and light intensity. Real-time data are transmitted to the Bamfa Cloud through Wi-Fi, and a mobile application provides users with instant access to data and control over watering and lighting adjustments. Our results demonstrate the effectiveness of the smart flowerpot in enabling automated monitoring of plant growth and environmental control. This innovation holds significant promise for advancing smart device development in ornamental horticulture and other related fields, enhancing efficiency, plant health, and overall user experience. Future research in this area has the potential to revolutionize horticultural practices and contribute to the advancement of smart agriculture.


Asunto(s)
Nube Computacional , Aplicaciones Móviles , Impresión Tridimensional , Temperatura , Horticultura
4.
Heliyon ; 9(5): e15753, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37153380

RESUMEN

Nowadays, among 3rd generation drug delivery systems, biodegradable polymeric based long-acting injectable depot has achieved tremendous success in clinical application. So far, there have been two dozen of commercial products of Poly (lactic-co-glycolic acid) microspheres available in the market. Recently, continuous manufacturing concept has been successfully applied on oral solid formulation from buzzword to reality. However, the polymeric injectable microspheres are still stayed at batch manufacturing phase due to the lack of understanding of knowledge matrix. In this study, micro-mixer as a plug-and-play emulsification modules, Raman spectroscopy and focused beam reflectance measurement as real-time monitoring modules are integrated into a novel semi-continuous manufacturing streamline to provides more efficient upscaling flexibility in microspheres production. In this end to end semi-continuous manufacturing process, amphiphilic block polymer monomethoxy-poly (ethylene glycol) modified PLGA (mPEG-PLGA) was used for encapsulating Gallic acid. Additionally, with guarantee of good robustness, the correlation relationship between critical process parameters, critical material attributes and critical quality attributes were investigated. The time-space evolution process and mechanism for formation of PEG-PLGA microsphere with particular morphology were elaborated. Altogether, this study firstly established semi-continuous manufacturing streamline for PLGA/PEG-PLGA microspheres, which would not only lower the cost of production, narrow process variability and smaller equipment/environmental footprint but also applied in-process control (IPC) and QbD principle on complicated production process of microspheres. Therefore, this study build confidence in the industrial development of PLGA/PEG-PLGA microspheres and establish best practice standards, which might be a quantum leap for developing PLGA microspheres in the future.

5.
Sci Total Environ ; 874: 162516, 2023 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-36868269

RESUMEN

The use of indoor air purifier (IAP) has received growing attention as a mitigation strategy for reducing indoor air pollution, but the evidence on their cardiovascular benefits is unclear. This study aims to evaluate whether the use of IAP can reduce the adverse effects of indoor particulate matter (PM) on cardiovascular health among young healthy population. A randomized, double-blind, cross-over, IAP intervention of 38 college students was conducted. The participants were assigned into two groups to receive the true and sham IAPs for 36 h in random order. Systolic and diastolic blood pressure (SBP; DBP), blood oxygen saturation (SpO2), heart rate variability (HRV) and indoor size-fractioned particulate matter (PM) were real-time monitored throughout the intervention. We found that IAP could reduce indoor PM by 41.7-50.5 %. Using IAP was significantly associated with a reduction of 2.96 mmHg (95 % CI: -5.71, -0.20) in SBP. Increased PM was significantly associated with increased SBP (e.g., 2.17 mmHg [0.53, 3.81], 1.73 mmHg [0.32, 3.14] and 1.51 mmHg [0.28, 2.75] for an IQR increment of PM1 [16.7 µg/m3], PM2.5 [20.6 µg/m3] and PM10 [37.9 µg/m3] at lag 0-2 h, respectively) and decreased SpO2 (-0.44 % [-0.57, -0.29], -0.41 % [-0.53, -0.30] and - 0.40 % [-0.51, -0.30] for PM1, PM2.5 and PM10 at lag 0-1 h, respectively), which could last for about 2 h. Using IAPs could halve indoor PM levels, even in relatively low air pollution settings. The exposure-response relationships suggested that the benefits of IAPs on BP may only be observed when indoor PM exposure is reduced to a certain level.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Contaminación del Aire , Humanos , Adulto Joven , Contaminación del Aire Interior/análisis , Frecuencia Cardíaca , Presión Sanguínea , Saturación de Oxígeno , Contaminación del Aire/efectos adversos , Material Particulado/análisis , Contaminantes Atmosféricos/análisis
6.
Membranes (Basel) ; 12(10)2022 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-36295677

RESUMEN

The high-pressure proton exchange membrane water electrolyzer (PEMWE) used for hydrogen production requires a high-operating voltage, which easily accelerates the decomposition of hydrogen molecules, resulting in the aging or failure of the high-pressure PEMWE. As the high-pressure PEMWE ages internally, uneven flow distribution can lead to large temperature differences, reduced current density, flow plate corrosion, and carbon paper cracking. In this study, a new type of micro hydrogen sensor is developed with integrated flexible seven-in-one (voltage; current; temperature; humidity; flow; pressure; and hydrogen) microsensors.

7.
Acta Pharm Sin B ; 12(1): 437-450, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35127397

RESUMEN

Dry powder inhalers (DPIs) had been widely used in lung diseases on account of direct pulmonary delivery, good drug stability and satisfactory patient compliance. However, an indistinct understanding of pulmonary delivery processes (PDPs) hindered the development of DPIs. Most current evaluation methods explored the PDPs with over-simplified models, leading to uncompleted investigations of the whole or partial PDPs. In the present research, an innovative modular process analysis platform (MPAP) was applied to investigate the detailed mechanisms of each PDP of DPIs with different carrier particle sizes (CPS). The MPAP was composed of a laser particle size analyzer, an inhaler device, an artificial throat and a pre-separator, to investigate the fluidization and dispersion, transportation, detachment and deposition process of DPIs. The release profiles of drug, drug aggregation and carrier were monitored in real-time. The influence of CPS on PDPs and corresponding mechanisms were explored. The powder properties of the carriers were investigated by the optical profiler and Freeman Technology four powder rheometer. The next generation impactor was employed to explore the aerosolization performance of DPIs. The novel MPAP was successfully applied in exploring the comprehensive mechanism of PDPs, which had enormous potential to be used to investigate and develop DPIs.

8.
Indoor Air ; 32(1): e12962, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34841578

RESUMEN

Fine particulate matter (PM2.5 ) concentrations show high variations in different microenvironments indoors, which has considerable impact on risk management. However, the real-time variations of PM2.5 exposure associated with per activity/microenvironment and intra-variation among family members remain undefined. In this study, real-time monitors were used to collect real-time PM2.5 data in different microenvironments in 32 households in urban community of China. Peak concentrations of PM2.5 were found in kitchen. The parallel levels of PM2.5 household indoor and outdoor indicated the benefit of clean energies use. To validly assess the health risk of individuals, we proposed a novel method to estimate the real-time exposure of all residents and firstly investigate the intra-variation of PM2.5 exposure among family members. The member who is responsible for cooking in the family had the maximum PM2.5 exposure. The ratios among intraindividual variations demonstrated children usually had lower exposure compared to the adults as they stayed more time in lower polluted microenvironments such as living room and bedroom. The exposure intensity in living room was above 1.0 for most residents, indicating it is warranted to alleviate the air pollution in living room. This study firstly focused on the intra differences of PM2.5 exposure among family members and provided a new insight for indoor air pollution management. The results suggested when adopting measures to reduce exposure, the microenvironments pattern of each member should be taken into consideration. Future work is welcomed to move another big step on this issue to protect the human health.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Adulto , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Niño , China , Culinaria/métodos , Monitoreo del Ambiente/métodos , Humanos , Material Particulado/análisis , Población Rural
9.
Front Nutr ; 8: 651804, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33869268

RESUMEN

Aquatic products, such as fish, are popular throughout the world due to their satisfying flavor characteristics as well as rich animal nutrition, and they provide high-value food therapy, but they are easily oxidized and spoiled. It is necessary to detect aquatic products through rapid and accurate technology. Low-field nuclear magnetic resonance (LF-NMR) and magnetic resonance imaging (MRI) have been widely used in the aquatic product industry due to their sensitivity, fast analysis, non-destructive nature and low cost. The applications of LF-NMR in the measurement of aquatic product quality and nutrients (water, fat, and protein) are summarized in this paper. Applications in aquatic products have been shown to depend on deep processing, storage and authentication. This review discusses the application of MRI technology in the quality control of aquatic products. Therefore, this review will guide the application of the aquatic products industry and aims to supply the reader with both the theory of the method and practical applications of the method for use as a rapid and non-destructive technology in scientific research and the industrial industry.

10.
Database (Oxford) ; 20202020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-32283556

RESUMEN

Improvement of edible bananas (a triploid and sterile crop) through conventional breeding is a challenging task owing to its recalcitrant nature for seed set, prolonged crop duration. In addition, the need of huge man power at different stages of progeny development and evaluation often leads to mislabeling, poor data management and loss of vital data. All this can be overcome by the application of advanced information technology source. This ensured secure and efficient data management such as storage, retrieval and data analysis and further could assist in tracking the breeding status in real time. Thus, a user-friendly web-based banana breeding tracker (BBT) has been developed using MySQL database with Hypertext Preprocessor (PHP). This BBT works on all operating systems with access to multiple users from anywhere at any time. Quick responsive (QR) code labels can be generated by the tracker, which can be decoded using QR scanner. Also for each and every updated progress in breeding stages, a new QR code can be generated, which in turn reduce labeling errors. Moreover, the tracker has additional tools to search, sort and filter the data from the data sets for efficient retrieval and analysis. This tracker is being upgraded with phenotypic and genotypic data that will be made available in the public domain for hastening the banana improvement program.


Asunto(s)
Bases de Datos Factuales , Musa/crecimiento & desarrollo , Musa/genética , Fitomejoramiento/métodos , Humanos , Almacenamiento y Recuperación de la Información/métodos , Internet , Ploidias , Interfaz Usuario-Computador
11.
Zhongguo Yi Liao Qi Xie Za Zhi ; 43(6): 418-421, 2019 Nov 30.
Artículo en Chino | MEDLINE | ID: mdl-31854526

RESUMEN

This paper designs and implements a low power portable bowel sound monitor, which adopts bone conduction transducer to collect bowel sound continuously for long time and transmit to phone by Bluetooth. Then the phone application can record, play and analyse the bowel sound digital data in real time. This paper also designs an experiment to collect bowel sound from healthy people and patients with intestinal obstruction. It is verified by clinicians that this monitor can accurately record and preserve the bowel sound of the detected people, and is not disturbed by the external environment.


Asunto(s)
Monitoreo Fisiológico , Humanos , Obstrucción Intestinal
12.
Min Metall Explor ; 36(4): 765-772, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31745535

RESUMEN

Diesel particulate matter (DPM) has been classified as a carcinogen to humans by the International Agency for Research on Cancer. As a result of its potential carcinogenic nature, DPM exposure is regulated by the Mine Safety and Health Administration. Currently, diesel emissions in the workplace are monitored by collecting the aerosol onto filters, which are then sent to a laboratory for thermal-optical analysis using the NIOSH method 5040. This process can take days or even weeks, and workers can potentially be exposed to excessive levels of DPM before the problem is identified. Moreover, the delay involved in getting the loaded filter to the lab inevitably means the loss of some of the more volatile organic carbon. To remedy this delay, researchers from the National Institute for Occupational Safety and Health are seeking to develop a field-portable, real-time method for measuring elemental and organic carbons in DPM aerosols. In the current study, the use of mid-infrared spectrometry was investigated. It is believed that mid-infrared spectroscopy is more suitable for use in a real-time field-portable device than thermo-optical analysis methods. This article presents a method for measuring organic carbon (OC) and elemental carbon (EC) in DPM for a broad range of OC/EC ratios. The method has been successfully applied to laboratory-generated and mine samples.

13.
Surg Innov ; 23(2): 115-23, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26603692

RESUMEN

INTRODUCTION: Perioperative bowel perfusion (local hemodynamic index [LHI]) was measured with a miniaturized dynamic light scattering (mDLS) device, aiming to determine whether anastomotic perfusion correlates with the anastomotic healing process and whether LHI measurement assists in the detection of anastomotic leakage (AL) in colorectal surgery. METHODS: A partial colectomy was performed in 21 male Wistar rats. Colonic and anastomotic LHIs were recorded during operation. On postoperative day (POD) 3, the rats were examined for AL manifestations. Anastomotic LHI was recorded before determining the anastomotic bursting pressure (ABP). The postoperative LHI measurements were repeated in 15 other rats with experimental colitis. Clinical manifestations and anastomotic LHI were also determined on POD3. Diagnostic value of LHI measurement was analyzed with the combined data from both experiments. RESULTS: Intraoperative LHI measurement showed no correlation with the ABP on POD3. Postoperative anastomotic LHI on POD3 was significantly correlated with ABP in the normal rats (R(2) = 0.52; P < .001) and in the rats with colitis (R(2) = 0.63; P = .0012). Anastomotic LHI on POD3 had high accuracy for identifying ABP <50 mm Hg (Area under the curve = 0.86; standard error = 0.065; P < .001). A cutoff point of 1236 yielded a sensitivity of 100% and a specificity of 65%. On POD3, rats with LHIs <1236 had significantly higher dehiscence rates (40% vs 0%), more weight loss, higher abscess severity, and lower ABPs (P < .05); worse anastomotic inflammation and collagen deposition were also found in the histological examination. CONCLUSION: Our data suggest that postoperative evaluation of anastomotic microcirculation with the mDLS device assists in the detection of AL in colorectal surgery.


Asunto(s)
Anastomosis Quirúrgica , Fuga Anastomótica/diagnóstico por imagen , Colon/cirugía , Dispersión Dinámica de Luz/métodos , Recto/cirugía , Cicatrización de Heridas/fisiología , Animales , Procesamiento de Imagen Asistido por Computador , Masculino , Ratas , Ratas Wistar , Sensibilidad y Especificidad
14.
Sensors (Basel) ; 15(11): 29535-46, 2015 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-26610511

RESUMEN

Carbon monoxide (CO) burns or explodes at over-standard concentration. Hence, in this paper, a Wifi-based, real-time monitoring of a CO system is proposed for application in the construction industry, in which a sensor measuring node is designed by low-frequency modulation method to acquire CO concentration reliably, and a digital filtering method is adopted for noise filtering. According to the triangulation, the Wifi network is constructed to transmit information and determine the position of nodes. The measured data are displayed on a computer or smart phone by a graphical interface. The experiment shows that the monitoring system obtains excellent accuracy and stability in long-term continuous monitoring.

15.
J Occup Environ Hyg ; 12(9): 577-87, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25894766

RESUMEN

Diesel exhaust (DE) contains a variety of toxic air pollutants, including diesel particulate matter (DPM) and gaseous contaminants (e.g., carbon monoxide (CO)). DPM is dominated by fine (PM2.5) and ultrafine particles (UFP), and can be representatively determined by its thermal-optical refractory as elemental carbon (EC) or light-absorbing characteristics as black carbon (BC). The currently accepted reference method for sampling and analysis of occupational exposure to DPM is the National Institute for Occupational Safety and Health (NIOSH) Method 5040. However, this method cannot provide in-situ short-term measurements of DPM. Thus, real-time monitors are gaining attention to better examine DE exposures in occupational settings. However, real-time monitors are subject to changing environmental conditions. Field measurements have reported interferences in optical sensors and subsequent real-time readings, under conditions of high humidity and abrupt temperature changes. To begin dealing with these issues, we completed a controlled study to evaluate five real-time monitors: Airtec real-time DPM/EC Monitor, TSI SidePak Personal Aerosol Monitor AM510 (PM2.5), TSI Condensation Particle Counter 3007, microAeth AE51 BC Aethalometer, and Langan T15n CO Measurer. Tests were conducted under different temperatures (55, 70, and 80°F), relative humidity (10, 40, and 80%), and DPM concentrations (50 and 200 µg/m(3)) in a controlled exposure facility. The 2-hr averaged EC measurements from the Airtec instrument showed relatively good agreement with NIOSH Method 5040 (R(2) = 0.84; slope = 1.17±0.06; N = 27) and reported ∼17% higher EC concentrations than the NIOSH reference method. Temperature, relative humidity, and DPM levels did not significantly affect relative differences in 2-hr averaged EC concentrations obtained by the Airtec instrument vs. the NIOSH method (p < 0.05). Multiple linear regression analyses, based on 1-min averaged data, suggested combined effects of up to 5% from relative humidity and temperature on real-time measurements. The overall deviations of these real-time monitors from the NIOSH method results were ≤20%. However, simultaneous monitoring of temperature and relative humidity is recommended in field investigations to understand and correct for environmental impacts on real-time monitoring data.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Monóxido de Carbono/análisis , Monitoreo del Ambiente/instrumentación , Material Particulado/análisis , Emisiones de Vehículos/análisis , Humedad , National Institute for Occupational Safety and Health, U.S. , Tamaño de la Partícula , Temperatura , Estados Unidos
16.
Yonago Acta Med ; 54(4): 75-82, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24031132

RESUMEN

Pneumothorax is usually diagnosed based on the attenuation of respiratory sounds of the affected side on auscultation, but it requires a skilled technique and is limited to subjective evaluation. Thus, we designed a device which analyzes and converts the frequency of auscultatory sounds to numerical values with a computer. With this device, the bilateral sound pressure levels were compared between groups of 25 healthy subjects and 21 patients with pneumothorax to investigate the efficacy of the diagnosing tool of pneumothorax. While recording respiratory sounds of the bilateral precordial regions, the fast Fourier transform was applied with a frequency analysis software, power spectra of the auscultatory sounds were displayed in real-time, and the sound pressure level was compared between the bilateral sides. The difference was investigated at frequencies judged as less likely to be influenced by cardiac sounds (200-400 Hz). No difference was observed in the control group (n = 25, P > 0.05), but respiratory sound attenuation was detectable on the affected side in the pneumothorax group (n = 21, P < 0.01 each for the paired Student's t-test and Wilcoxon signed-rank test). When the cutoff value was 8 dB, the sensitivity and specificity as diagnostic tool of pneumothorax was 71.4% and 100%, respectively. This device would facilitate the detection of occult pneumothorax at accident scenes, in emergency rooms and in intensive care units.

17.
Acta Histochem Cytochem ; 42(3): 89-93, 2009 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-19617956

RESUMEN

In mammalian circadian rhythms, the transcriptional-translational feedback loop (TTFL) consisting of a set of clock genes is believed to elicit the circadian clock oscillation. The TTFL model explains that the accumulation and degradation of mPER and mCRY proteins control the period-length (tau) of the circadian clock. Although recent studies revealed that the Casein Kinase I epsilon delta (CKI epsilon delta) regulates the phosphorylation of mPER proteins and the circadian period-length, other kinases are also likely to contribute the phosphorylation of mPER. Here, we performed small scale screening using 84 chemical compounds known as kinase inhibitors to identify candidates possibly affecting the circadian period-length in mammalian cells. Screening by this high-throughput real-time bioluminescence monitoring system revealed that the several chemical compounds apparently lengthened the cellular circadian clock oscillation. These compounds are known as inhibitors against kinases such as Casein Kinase II (CKII), PI3-kinase (PI3K) and c-Jun N-terminal Kinase (JNK) in addition to CKI epsilon delta. Although these kinase inhibitors may have some non-specific effects on other factors, our mini screening identified new candidates contributing to period-length control in mammalian cells.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA