Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Nephrol Dial Transplant ; 38(2): 455-462, 2023 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-35212731

RESUMEN

BACKGROUND: Frailty is associated with adverse outcomes in patients undergoing hemodialysis (HD). However, no study has used various frailty assessments in patients on HD to examine their association with clinical events. In this study, we investigated the association between clinical events and six frailty scales. METHODS: Outpatients who underwent HD between 2018 and 2020 were retrospectively enrolled. Frailty was defined using the Fried Frailty Phenotype, Study of Osteoporotic Fractures (SOF) Index, Short Physical Performance Battery (SPPB), Frail Screening Index, FRAIL scale and Clinical Frailty Scale. Outcomes were clinical events, including a composite of multiple (i.e. recurrent) all-cause hospitalizations, fractures and/or all-cause mortality. The association of clinical events and the frailty scales were investigated using negative binomial regression analysis. RESULTS: Fried Frailty Phenotype [incident rate ratio (IRR), 1.62; 95% confidence interval (CI), 1.49-1.76], SOF Index (IRR, 1.42; 95% CI, 1.10-1.83), SPPB (IRR, 1.79; 95% CI, 1.11-2.88) and Clinical Frailty Scale (IRR, 1.65; 95% CI, 1.04-2.61) were significantly associated with clinical events. However, Frail Screening Index (IRR, 1.38; 95% CI, 0.60-3.18) and FRAIL scale (IRR, 1.30; 95% CI, 0.88-1.92) showed no significant association with clinical events. CONCLUSIONS: Objective frailty assessments (SPPB) and medical staff impression-based frailty (Clinical Frailty Scale) may be useful prognostic predictors for patients on HD. Questionnaire-based frailty assessment should be carefully considered when used as a measurement of frailty.


Asunto(s)
Fragilidad , Humanos , Anciano , Fragilidad/diagnóstico , Fragilidad/etiología , Anciano Frágil , Estudios Retrospectivos , Diálisis Renal/efectos adversos , Pronóstico
2.
Eur J Epidemiol ; 33(12): 1179-1191, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30151727

RESUMEN

It has long been known that relatively high-dose ionising radiation exposure (> 1 Gy) can induce cataract, but there has been no evidence that this occurs at low doses (< 100 mGy). To assess low-dose risk, participants from the US Radiologic Technologists Study, a large, prospective cohort, were followed from date of mailed questionnaire survey completed during 1994-1998 to the earliest of self-reported diagnosis of cataract/cataract surgery, cancer other than non-melanoma skin, or date of last survey (up to end 2014). Cox proportional hazards models with age as timescale were used, adjusted for a priori selected cataract risk factors (diabetes, body mass index, smoking history, race, sex, birth year, cumulative UVB radiant exposure). 12,336 out of 67,246 eligible technologists reported a history of diagnosis of cataract during 832,479 person years of follow-up, and 5509 from 67,709 eligible technologists reported undergoing cataract surgery with 888,420 person years of follow-up. The mean cumulative estimated 5-year lagged eye-lens absorbed dose from occupational radiation exposures was 55.7 mGy (interquartile range 23.6-69.0 mGy). Five-year lagged occupational radiation exposure was strongly associated with self-reported cataract, with an excess hazard ratio/mGy of 0.69 × 10-3 (95% CI 0.27 × 10-3 to 1.16 × 10-3, p < 0.001). Cataract risk remained statistically significant (p = 0.030) when analysis was restricted to < 100 mGy cumulative occupational radiation exposure to the eye lens. A non-significantly increased excess hazard ratio/mGy of 0.34 × 10-3 (95% CI - 0.19 × 10-3 to 0.97 × 10-3, p = 0.221) was observed for cataract surgery. Our results suggest that there is excess risk for cataract associated with radiation exposure from low-dose and low dose-rate occupational exposures.


Asunto(s)
Técnicos Medios en Salud , Catarata/etiología , Enfermedades Profesionales/epidemiología , Exposición Profesional/efectos adversos , Exposición a la Radiación/efectos adversos , Adulto , Técnicos Medios en Salud/estadística & datos numéricos , Catarata/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Enfermedades Profesionales/etiología , Exposición Profesional/análisis , Exposición a la Radiación/estadística & datos numéricos , Factores de Riesgo , Tecnología Radiológica/estadística & datos numéricos , Estados Unidos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA