Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 182
Filtrar
1.
BMC Pulm Med ; 24(1): 437, 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39238010

RESUMEN

BACKGROUND: Idiopathic Pulmonary Fibrosis (IPF) is a progressive fibrotic lung disease. However, the field of quantitative CT scan analysis in conjunction with pulmonary function test for IPF patients remains relatively understudied. In this study, we evaluated the diagnostic value of features derived high-resolution computed tomography (HRCT) for patients with IPF and correlated them with pulmonary function tests. METHODS: We retrospectively analyzed the chest HRCT images and pulmonary function test results of 52 patients with IPF during the same period (1 week) and selected 52 healthy individuals, matched for sex, age, and body mass index (BMI) and with normal chest HRCT as controls. HRCT scans were performed using a Philips 256-row Brilliance iCT scanner with standardized parameters. Lung function tests were performed using a Jaeger volumetric tracer for forced vital capacity (FVC), total lung capacity (TLC), forced expiratory volume in first second (FEV1), FEV1/FVC, carbon monoxide diffusing capacity (DLCO), and maximum ventilation volume (MVV) metrics. CT quantitative analysis, including tissue segmentation and threshold-based quantification of lung abnormalities, was performed using 3D-Slicer software to calculate the percentage of normal lung areas (NL%), percentage of ground-glass opacity areas (GGO%), percentage of fibrotic area (F%) and abnormal lesion area percentage (AA%). Semi-quantitative analyses were performed by two experienced radiologists to assess disease progression. The aortic-to-sternal distance (ASD) was measured on axial images as a standardized parameter. Spearman or Pearson correlation analysis and multivariate stepwise linear regression were used to analyze the relationship between the data in each group, and the ROC curve was used to determine the optimal quantitative CT metrics for identifying IPF and controls. RESULTS: ROC curve analysis showed that F% distinguished the IPF patient group from the control group with the largest area under the curve (AUC) of 0.962 (95% confidence interval: 0.85-0.96). Additionally, with F% = 4.05% as the threshold, the Youden's J statistic was 0.827, with a sensitivity of 92.3% and a specificity of 90.4%. The ASD was significantly lower in the late stage of progression than in the early stage (t = 5.691, P < 0.001), with a mean reduction of 2.45% per month. Quantitative CT indices correlated with all pulmonary function parameters except FEV1/FVC, with the highest correlation coefficients observed for F% and TLC%, FEV1%, FVC%, MVV% (r = - 0.571, - 0.520, - 0.521, - 0.555, respectively, all P-values < 0.001), and GGO% was significantly correlated with DLCO% (r = - 0.600, P < 0.001). Multiple stepwise linear regression analysis showed that F% was the best predictor of TLC%, FEV1%, FVC%, and MVV% (R2 = 0.301, 0.301, 0.300, and 0.302, respectively, all P-values < 0.001), and GGO% was the best predictor of DLCO% (R2 = 0.360, P < 0.001). CONCLUSIONS: Quantitative CT analysis can be used to diagnose IPF and assess lung function impairment. A decrease in the ASD may indicate disease progression.


Asunto(s)
Fibrosis Pulmonar Idiopática , Pulmón , Pruebas de Función Respiratoria , Tomografía Computarizada por Rayos X , Humanos , Fibrosis Pulmonar Idiopática/diagnóstico por imagen , Fibrosis Pulmonar Idiopática/fisiopatología , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Capacidad Vital , Volumen Espiratorio Forzado , Estudios de Casos y Controles , Capacidad Pulmonar Total , Curva ROC , Capacidad de Difusión Pulmonar
2.
JBMR Plus ; 8(9): ziae096, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39183821

RESUMEN

The estimation of BMD with CT scans requires a calibration method, usually based on a phantom. In asynchronous calibration, the phantom is scanned separately from the patient. A standardized acquisition protocol must be used to avoid variations between patient and phantom. However, variations can still be induced, for example, by temporal fluctuations or patient characteristics. Based on the further use of 739 forensic and 111 clinical CT scans, this study uses the proximal femur BMD value ("total hip") to assess asynchronous calibration accuracy, using in-scan calibration as ground truth. It identifies the parameters affecting the calibration accuracy and quantifies their impact. For time interval and table height, the impact was measured by calibrating the CT scan twice (once using the phantom scan with closest acquisition parameters and once using a phantom scan with standard values) and comparing the calibration accuracy. For other parameters such as body weight, the impact was measured by computing a linear regression between parameter values and calibration accuracy. Finally, this study proposes correction methods to reduce the effect of these parameters and improve the calibration accuracy. The BMD error of the asynchronous calibration, using the phantom scan with the closest acquisition parameters, was -1.2 ± 1.7% for the forensic and - 1.6 ± 3.5% for the clinical dataset. Among the parameters studied, time interval and body weight were identified as the main sources of error for asynchronous calibration, followed by table height and reconstruction kernel. Based on these results, a correction method was proposed to improve the calibration accuracy.

3.
EJNMMI Res ; 14(1): 75, 2024 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-39182210

RESUMEN

BACKGROUND: Serum bone turnover markers offer limited insight into metabolic activity at the individual vertebra level in osteoporosis. This study introduces a novel image-derived bone turnover marker for individual vertebrae to address this limitation, utilizing volumetric density-adjusted quantitative bone single-photon emission computed tomography/computed tomography (SPECT/CT) with [99mTc]Tc-DPD. This retrospective study included 177 lumbar vertebrae from 55 postmenopausal South Korean women. The mean standardized uptake value (SUVmean, g/cm3) and volumetric bone mineral density (vBMD, mg/cm3) were determined within a 2-cm³ volume of interest in the trabecular portion of each vertebra using quantitative SPECT and CT. The density-adjusted mean standardized uptake value (dSUVmean) was calculated by dividing the SUVmean by the vBMD and multiplying by 1,000. RESULTS: SUVmean correlated positively with vBMD (r = 0.60, p < 0.001). Conversely, dSUVmean correlated negatively with vBMD (ρ = -0.66, p < 0.001), highlighting the inverse relationship between bone mass and turnover after density adjustment of SUVmean. Patients with major osteoporotic fractures had lower vBMD (62.5 ± 29.4 vs. 92.3 ± 27.4 mg/cm³, p = 0.001) but higher dSUVmean (100.8 ± 60.7 vs. 62.6 ± 17.5, p = 0.001) compared to those without fractures, reinforcing the association between fracture prevalence, low bone mass, and high bone turnover. CONCLUSION: Volumetric density-adjusted quantitative bone SPECT/CT offers a novel image-derived bone turnover marker for assessing bone turnover in osteoporosis. This method provides a precise assessment of fragility at the individual vertebra level, which may enhance personalized osteoporosis management.

5.
Eur Heart J Imaging Methods Pract ; 2(1): qyae035, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39045181

RESUMEN

Aims: A comparison of diagnostic performance comparing AI-QCTISCHEMIA, coronary computed tomography angiography using fractional flow reserve (CT-FFR), and physician visual interpretation on the prediction of invasive adenosine FFR have not been evaluated. Furthermore, the coronary plaque characteristics impacting these tests have not been assessed. Methods and results: In a single centre, 43-month retrospective review of 442 patients referred for coronary computed tomography angiography and CT-FFR, 44 patients with CT-FFR had 54 vessels assessed using intracoronary adenosine FFR within 60 days. A comparison of the diagnostic performance among these three techniques for the prediction of FFR ≤ 0.80 was reported. The mean age of the study population was 65 years, 76.9% were male, and the median coronary artery calcium was 654. When analysing the per-vessel ischaemia prediction, AI-QCTISCHEMIA had greater specificity, positive predictive value (PPV), diagnostic accuracy, and area under the curve (AUC) vs. CT-FFR and physician visual interpretation CAD-RADS. The AUC for AI-QCTISCHEMIA was 0.91 vs. 0.76 for CT-FFR and 0.62 for CAD-RADS ≥ 3. Plaque characteristics that were different in false positive vs. true positive cases for AI-QCTISCHEMIA were max stenosis diameter % (54% vs. 67%, P < 0.01); for CT-FFR were maximum stenosis diameter % (40% vs. 65%, P < 0.001), total non-calcified plaque (9% vs. 13%, P < 0.01); and for physician visual interpretation CAD-RADS ≥ 3 were total non-calcified plaque (8% vs. 12%, P < 0.01), lumen volume (681 vs. 510 mm3, P = 0.02), maximum stenosis diameter % (40% vs. 62%, P < 0.001), total plaque (19% vs. 33%, P = 0.002), and total calcified plaque (11% vs. 22%, P = 0.003). Conclusion: Regarding per-vessel prediction of FFR ≤ 0.8, AI-QCTISCHEMIA revealed greater specificity, PPV, accuracy, and AUC vs. CT-FFR and physician visual interpretation CAD-RADS ≥ 3.

6.
Skeletal Radiol ; 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38902421

RESUMEN

For older Caucasian women and men, the QCT (quantitative CT) lumbar spine (LS) bone mineral density (BMD) threshold for classifying osteoporosis is 80 mg/ml. It was recently proposed that, for older East Asian women, the QCT LS BMD value equivalent to the Caucasian women's threshold of 80 mg/mL is about 45∼50 mg/ml. For a data of 328 cases of Chinese men (age: 73.6 ± 4.4 years) who had QCT LS BMD and DXA LS BMD at the same time and with the DXA BMD value of ≤ 0.613 g/cm2 to classify osteoporosis, the corresponding QCT LS BMD threshold is 53 mg/ml. Osteoporotic-like vertebral fracture sum score (OLVFss) ≤ -2.5 has been proposed to diagnose osteoporosis. For 316 cases of Chinese men (age:73.7±4.5 years), OLVFss ≤ -2.5 defines an osteoporosis prevalence of 4.4%; to achieve this osteoporosis prevalence, the corresponding QCT LS BMD value is < 47.5 mg/ml. In the China Action on Spine and Hip Status study, a Genant grades 2/3 radiographic 'osteoporotic vertebral fracture' prevalence was 2.84% for Chinese men (total n = 1267, age: 62.77 ± 9.20 years); to achieve this osteoporosis prevalence, the corresponding BMD value was < 42.5 mg/ml. In a study of 357 Beijing older men, according to the clinical fragility fracture prevalence and femoral neck DXA T-score, the QCT LS BMD value to classify osteoporosis was between 39.45 mg/ml and 51.38 mg/ml. For older Chinese men (≥ 50 years), we recommend the cutpoint for the QCT LS BMD definition of osteoporosis to be 45∼50 mg/ml which is the same as the value for Chinese women.

7.
J Appl Clin Med Phys ; 25(7): e14383, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38801204

RESUMEN

OBJECTIVE: To assess the impact of scatter radiation on quantitative performance of first and second-generation dual-layer spectral computed tomography (DLCT) systems. METHOD: A phantom with two iodine inserts (1 and 2 mg/mL) configured to intentionally introduce high scattering conditions was scanned with a first- and second-generation DLCT. Collimation widths (maximum of 4 cm for first generation and 8 cm for second generation) and radiation dose levels were varied. To evaluate the performance of both systems, the mean CT numbers of virtual monoenergetic images (MonoEs) at different energies were calculated and compared to expected values. MonoEs at 50  versus 150 keV were plotted to assess material characterization of both DLCTs. Additionally, iodine concentrations were determined, plotted, and compared against expected values. For each experimental scenario, absolute errors were reported. RESULTS: An experimental setup, including a phantom design, was successfully implemented to simulate high scatter radiation imaging conditions. Both CT scanners illustrated high spectral accuracy for small collimation widths (1 and 2 cm). With increased collimation (4 cm), the second-generation DLCT outperformed the earlier DLCT system. Further, the spectral performance of the second-generation DLCT at an 8 cm collimation width was comparable to a 4 cm collimation on the first-generation DLCT. A comparison of the absolute errors between both systems at lower energy MonoEs illustrates that, for the same acquisition parameters, the second-generation DLCT generated results with decreased errors. Similarly, the maximum error in iodine quantification was less with second-generation DLCT (0.45  and 0.33 mg/mL for the first and second-generation DLCT, respectively). CONCLUSION: The implementation of a two-dimensional anti-scatter grid in the second-generation DLCT improves the spectral quantification performance. In the clinical routine, this improvement may enable additional clinical benefits, for example, in lung imaging.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Dispersión de Radiación , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
8.
Artículo en Inglés | MEDLINE | ID: mdl-38765483

RESUMEN

Parametric response mapping (PRM) is a voxel-based quantitative CT imaging biomarker that measures the severity of chronic obstructive pulmonary disease (COPD) by analyzing both inspiratory and expiratory CT scans. Although PRM-derived measurements have been shown to predict disease severity and phenotyping, their quantitative accuracy is impacted by the variability of scanner settings and patient conditions. The aim of this study was to evaluate the variability of PRM-based measurements due to the changes in the scanner types and configurations. We developed 10 human chest models with emphysema and air-trapping at end-inspiration and end-expiration states. These models were virtually imaged using a scanner-specific CT simulator (DukeSim) to create CT images at different acquisition settings for energy-integrating and photon-counting CT systems. The CT images were used to estimate PRM maps. The quantified measurements were compared with ground truth values to evaluate the deviations in the measurements. Results showed that PRM measurements varied with scanner type and configurations. The emphysema volume was overestimated by 3 ± 9.5 % (mean ± standard deviation) of the lung volume, and the functional small airway disease (fSAD) volume was underestimated by 7.5±19 % of the lung volume. PRM measurements were more accurate and precise when the acquired settings were photon-counting CT, higher dose, smoother kernel, and larger pixel size. This study demonstrates the development and utility of virtual imaging tools for systematic assessment of a quantitative biomarker accuracy.

9.
Acad Radiol ; 2024 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-38679527

RESUMEN

RATIONALE AND OBJECTIVES: Fibrotic scarring in idiopathic pulmonary fibrosis (IPF) typically develops first in the posterior-basal lung tissue before advancing to involve more of the lung. The complexity of lung shape in the costo-diaphragmatic region has been proposed as a potential factor in this regional development. Intrinsic and disease-related shape could therefore be important for understanding IPF risk and its staging. We hypothesized that lung and lobe shape in IPF would have important differences from controls. MATERIALS AND METHODS: A principal component (PC) analysis was used to derive a statistical shape model (SSM) of the lung for a control cohort aged > 50 years (N = 39), using segmented lung and fissure surface data from CT imaging. Individual patient shape models derived for baseline (N = 18) and follow-up (N = 16) CT scans in patients with IPF were projected to the SSM to describe shape as the sum of the SSM average and weighted PC modes. Associations between the first four PC shape modes, lung function, percentage of fibrosis (fibrosis%) and pulmonary vessel-related structures (PVRS%), and other tissue metrics were assessed and compared between the two cohorts. RESULTS: Shape was different between IPF and controls (P < 0.05 for all shape modes), with IPF shape forming a distinct shape cluster. Shape had a negative relationship with age in controls (P = 0.013), but a positive relationship with age in IPF (P = 0.026). Some features of shape changed on follow-up. Shape in IPF was associated with fibrosis% (P < 0.05) and PVRS% (P < 0.05). CONCLUSION: Quantitative comparison of lung and lobe shape in IPF with controls of a similar age reveals shape differences that are strongly associated with age and percent fibrosis. The clustering of IPF cohort shape suggests that it could be an important feature to describe disease.

10.
Respir Care ; 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38594036

RESUMEN

BACKGROUND: The use of prone position (PP) has been widespread during the COVID-19 pandemic. Whereas it has demonstrated benefits, including improved oxygenation and lung aeration, the factors influencing the response in terms of gas exchange to PP remain unclear. In particular, the association between baseline quantitative computed tomography (CT) scan results and gas exchange response to PP in invasively ventilated subjects with COVID-19 ARDS is unknown. The present study aimed to compare baseline quantitative CT results between subjects responding to PP in terms of oxygenation or CO2 clearance and those who did not. METHODS: This was a single-center, retrospective observational study including critically ill, invasively ventilated subjects with COVID-19-related ARDS admitted to the ICUs of Niguarda Hospital between March 2020-November 2021. Blood gas samples were collected before and after PP. Subjects in whom the PaO2 /FIO2 increase was ≥ 20 mm Hg after PP were defined as oxygen responders. CO2 responders were defined when the ventilatory ratio (VR) decreased during PP. Automated quantitative CT analyses were performed to obtain tissue mass and density of the lungs. RESULTS: One hundred twenty-five subjects were enrolled, of which 116 (93%) were O2 responders and 51 (41%) CO2 responders. No difference in quantitative CT characteristics and oxygen were observed between responders and non-responders (tissue mass 1,532 ± 396 g vs 1,654 ± 304 g, P = .28; density -544 ± 109 HU vs -562 ± 58 HU P = .42). Similar findings were observed when dividing the population according to CO2 response (tissue mass 1,551 ± 412 g vs 1,534 ± 377 g, P = .89; density -545 ± 123 HU vs -546 ± 94 HU, P = .99). CONCLUSIONS: Most subjects with COVID-19-related ARDS improved their oxygenation at the first pronation cycle. The study suggests that baseline quantitative CT scan data were not associated with the response to PP in oxygenation or CO2 in mechanically ventilated subjects with COVID-19-related ARDS.

11.
Pol J Radiol ; 89: e140-e147, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38550958

RESUMEN

Purpose: Solid pancreatic lesions might have overlapping findings in portal venous phase computed tomography (CT). In this study, we aimed to investigate the quantitative and qualitative imaging features of solid pancreas lesions based on subtype and grade. Material and methods: The study group consisted of 159 patients with solid pancreatic tumours detected after exclusion criteria. According to the pathology results, the patients were divided into 3 groups as PDAC (pancreatic ductal adenocarcinoma, n = 137), PNET (pancreatic neuroendocrine tumour, n = 15), and SC (sarcomatoid carcinoma, n = 7). PDAC and PNET lesions were evaluated in 3 subgroups according to grade. Results: There was no difference between the groups in terms of age, gender, tumour localisation, and internal structure (p = 0.23, p = 0.81, p = 0.19, and p = 0.94, respectively). Qualitative features significantly differed in terms of tumour margin feature, visual tumour density, presence of cystic component, and presence of necrosis (p = 0.01, p = 0.0001, p = 0.002, and p = 0.004, respectively). Tumour size, Tmden, Tmden/VPden, and Tmden/PanPden showed differences between groups (p = 0.0001, p = 0.002, p = 0.0001, p = 0.0001, respectively). The presence of cystic density in PDAC patients differed according to grade (p = 0.01). Conclusions: While ill-defined irregular margins, hypodense visual tumour density, no cystic component, low value of Tmden, and low ratios of Tmden/VPden and Tmden/PanPden indicate PDAC, regular margins, iso-or hyperdense visual tumour density, cystic component, high value of Tmden, and high ratios of Tmden/VPden and Tmden/PanPden indicate PNET. SC can be differentiated from them by containing necrosis and reaching larger sizes. The presence of a cystic component in PDAC patients indicates high grade.

12.
Health Sci Rep ; 7(3): e1734, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38500635

RESUMEN

Aims: To investigate the characteristics and diagnostic performance of quantitative computed tomography (QCT) parameters in eosinophilic chronic obstructive pulmonary disease (COPD) patients. Methods: High-resolution CT scans of COPD patients were retrospectively analyzed, and various emphysematous parenchyma measurements, including lung volume (LC), lung mean density (LMD), lung standard deviation (LSD), full-width half maximum (FWHM), and lung relative voxel number (LRVN) were performed. The QCT parameters were compared between eosinophilic and noneosinophilic COPD patients, using a definition of eosinophilic COPD as blood eosinophil values ≥ 300 cells·µL-1 on at least three times. Receiver operating characteristic curves and area under the curve (ROC-AUC) and python were used to evaluate discriminative efficacy of QCT. Results: Noneosinophilic COPD patients had a significantly lower TLMD (-846.3 ± 47.9 Hounsfield Unit [HU]) and TFWHM(162.5 ± 30.6 HU) compared to eosinophilic COPD patients (-817.8 ± 54.4, 177.3 ± 33.1 HU, respectively) (p = 0.018, 0.03, respectively). Moreover, the total LC (TLC) and TLSD were significantly lower in eosinophilic COPD group (3234.4 ± 1145.8, 183.8 ± 33.9 HU, respectively) than the noneosinophilic COPD group (5600.2 ± 1248.4, 203.5 ± 20.4 HU, respectively) (p = 0.009, 0.002, respectively). The ROC-AUC values for TLC, TLMD, TLSD, and TFWHM were 0.91 (95% confidence interval [CI], 0.828-0.936), 0.66 (95% CI, 0.546-0.761), 0.64 (95% CI, 0.524-0.742), and 0.63 (95% CI, 0.511-0.731), respectively. When the TLC value was 4110 mL, the sensitivity was 90.7% (95% CI, 79.7-96.9), specificity was 77.8% (95% CI, 57.7-91.4) and accuracy was 86.4%. Notably, TLC demonstrated the highest discriminative efficiency with an F1 Score of 0.79, diagnostic Odds Ratio of 34.3 and Matthews Correlation Coefficient of 0.69, surpassing TLMD (0.55, 3.66, 0.25), TLSD (0.56, 3.95, 0.26), and TFWHM (0.56, 4.16, 0.33). Conclusion: Eosinophilic COPD patients exhibit lower levels of emphysema and a more uniform density distribution throughout the lungs compared to noneosinophilic COPD patients. Furthermore, TLC demonstrated the highest diagnostic efficiency and may serve as a valuable diagnostic marker for distinguishing between the two groups.

13.
Ann Am Thorac Soc ; 21(7): 1022-1033, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38530051

RESUMEN

Rationale: Rates of emphysema progression vary in chronic obstructive pulmonary disease (COPD), and the relationships with vascular and airway pathophysiology remain unclear. Objectives: We sought to determine if indices of peripheral (segmental and beyond) pulmonary arterial dilation measured on computed tomography (CT) are associated with a 1-year index of emphysema (EI; percentage of voxels <-950 Hounsfield units) progression. Methods: Five hundred ninety-nine former and never-smokers (Global Initiative for Chronic Obstructive Lung Disease stages 0-3) were evaluated from the SPIROMICS (Subpopulations and Intermediate Outcome Measures in COPD Study) cohort: rapid emphysema progressors (RPs; n = 188, 1-year ΔEI > 1%), nonprogressors (n = 301, 1-year ΔEI ± 0.5%), and never-smokers (n = 110). Segmental pulmonary arterial cross-sectional areas were standardized to associated airway luminal areas (segmental pulmonary artery-to-airway ratio [PAARseg]). Full-inspiratory CT scan-derived total (arteries and veins) pulmonary vascular volume (TPVV) was compared with small vessel volume (radius smaller than 0.75 mm). Ratios of airway to lung volume (an index of dysanapsis and COPD risk) were compared with ratios of TPVV to lung volume. Results: Compared with nonprogressors, RPs exhibited significantly larger PAARseg (0.73 ± 0.29 vs. 0.67 ± 0.23; P = 0.001), lower ratios of TPVV to lung volume (3.21 ± 0.42% vs. 3.48 ± 0.38%; P = 5.0 × 10-12), lower ratios of airway to lung volume (0.031 ± 0.003 vs. 0.034 ± 0.004; P = 6.1 × 10-13), and larger ratios of small vessel volume to TPVV (37.91 ± 4.26% vs. 35.53 ± 4.89%; P = 1.9 × 10-7). In adjusted analyses, an increment of 1 standard deviation in PAARseg was associated with a 98.4% higher rate of severe exacerbations (95% confidence interval, 29-206%; P = 0.002) and 79.3% higher odds of being in the RP group (95% confidence interval, 24-157%; P = 0.001). At 2-year follow-up, the CT-defined RP group demonstrated a significant decline in postbronchodilator percentage predicted forced expiratory volume in 1 second. Conclusions: Rapid one-year progression of emphysema was associated with indices indicative of higher peripheral pulmonary vascular resistance and a possible role played by pulmonary vascular-airway dysanapsis.


Asunto(s)
Progresión de la Enfermedad , Arteria Pulmonar , Enfisema Pulmonar , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Enfisema Pulmonar/diagnóstico por imagen , Enfisema Pulmonar/fisiopatología , Anciano , Persona de Mediana Edad , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/fisiopatología , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Volumen Espiratorio Forzado , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen
14.
Skeletal Radiol ; 53(8): 1473-1480, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38411702

RESUMEN

For Caucasian women, the QCT (quantitative CT) lumbar spine (LS) bone mineral density (BMD) cutpoint value for classifying osteoporosis is 80 mg/ml. At the age of approximate 78 years, US Caucasian women QCT LS BMD population mean is 80 mg/ml, while that of Chinese women and Japanese women is around 50 mg/ml. Correlation analyses show, for Chinese women and Japanese women, QCT LS BMD of 45 mg/ml corresponds to the dual-energy X-ray absorptiometry cutpoint value for classifying osteoporosis. For Chinese and Japanese women, if QCT LS BMD 80 mg/ml is used as the threshold to classify osteoporosis, then the specificity of classifying subjects with vertebral fragility fracture into the osteoporotic group is low, whereas threshold of 45 mg/ml approximately achieve a similar separation for women with and without vertebral fragility fracture as the reports for Caucasian women. Moreover, by using 80mg/ml as the cutpoint value, LS QCT leads to excessively high prevalence of osteoporosis for Chinese women, with the discordance between hip dual-energy X-ray absorptiometry and LS QCT measures far exceeding expectation. Considering the different bone properties and the much lower prevalence of fragility fractures in the East Asian women compared with Caucasians, we argue that the QCT cutpoint value for classifying osteoporosis among older East Asian women will be close to and no more than 50 mg/ml LS BMD. We suggest that it is also imperative the QCT osteoporosis classification criterion for East Asian male LS, and male and female hips be re-examined.


Asunto(s)
Densidad Ósea , Pueblos del Este de Asia , Vértebras Lumbares , Población Blanca , Anciano , Femenino , Humanos , Persona de Mediana Edad , Absorciometría de Fotón , Vértebras Lumbares/diagnóstico por imagen , Osteoporosis/diagnóstico por imagen , Prevalencia , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
15.
Heliyon ; 10(2): e24758, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38312599

RESUMEN

Background: Eexploring the limits of CT cranial perfusion scan acquisition intervals and predicting time to peak. Methods: A retrospective analysis was conducted on 45 patients with suspected stroke who underwent brain CTP scans. Different sampling intervals were set based on the TDC. The patients were divided into four groups: Group 1 underwent continuous scanning with a uniform interval of 1.5 s; Group 2 had a uniform interval of 3 s; Group 3 had a 1.5-s interval between arterial and venous peak vertices with 1 point retained before and after the peak for 1.5 s and with a remaining acquisition interval of 4.5 s; and Group 4 had a uniform interval of 4.5 s. Statistical analysis was performed on the perfusion parameters of each group. Additionally, in 286 patients who underwent head and neck CTA examinations, the peak time of contrast medium was recorded, and the peak time was predicted based on factors such as age, height, weight, heart rate, systolic blood pressure, diastolic blood pressure, triglycerides, and total cholesterol. The results compared with Group 1 and Group 2, as well as Group 1 and Group 3, the P values of CBF, CBV, MTT, and Tmax in the left and right cerebral hemispheres of healthy subjects and in the infarct and noninfarct areas of patients were all >0.05. A comparison between Group 1 and Group 4 showed that right cerebral hemisphere CBF and CBV, left cerebral hemisphere CBF, CBV, and Tmax, infarct area CBV and Tmax, and noninfarct area CBF, CBV, and MTT had P values > 0.05, while other groups all had P values < 0.05. Bland‒Altman analysis showed that the perfusion parameters in Group 1 were consistent with those in Group 2, and those in Group 1 were consistent with those in Group 3. The radiation doses in the second and third groups were lower, and the dose in the third group was lower than that in the second group. Conclusion: Continuous acquisition between the peak points of the arterial and venous phases, with 1 point reserved before and after the peak and a 4.5-s interval for the rest, represents the maximum time interval for CTP scanning and can effectively reduce the radiation dose. The formula Tmax (s) = 0.290 × height (cm) - 0.226 × heart rate (times/min) + 0.216 × age (years) - 1.901 × triglycerides (mmol/L) - 0.061 × systolic blood pressure (mmHg) - 7.216 (R2 = 0.449, F = 17.905, P < 0.01) was established for predicting time to peak enhancement.

16.
BMC Musculoskelet Disord ; 25(1): 176, 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38413868

RESUMEN

OBJECTIVE: To develop and evaluate a deep learning model based on chest CT that achieves favorable performance on opportunistic osteoporosis screening using the lumbar 1 + lumbar 2 vertebral bodies fusion feature images, and explore the feasibility and effectiveness of the model based on the lumbar 1 vertebral body alone. MATERIALS AND METHODS: The chest CT images of 1048 health check subjects from January 2021 to June were retrospectively collected as the internal dataset (the segmentation model: 548 for training, 100 for tuning and 400 for test. The classification model: 530 for training, 100 for validation and 418 for test set). The subjects were divided into three categories according to the quantitative CT measurements, namely, normal, osteopenia and osteoporosis. First, a deep learning-based segmentation model was constructed, and the dice similarity coefficient(DSC) was used to compare the consistency between the model and manual labelling. Then, two classification models were established, namely, (i) model 1 (fusion feature construction of lumbar vertebral bodies 1 and 2) and (ii) model 2 (feature construction of lumbar 1 alone). Receiver operating characteristic curves were used to evaluate the diagnostic efficacy of the models, and the Delong test was used to compare the areas under the curve. RESULTS: When the number of images in the training set was 300, the DSC value was 0.951 ± 0.030 in the test set. The results showed that the model 1 diagnosing normal, osteopenia and osteoporosis achieved an AUC of 0.990, 0.952 and 0.980; the model 2 diagnosing normal, osteopenia and osteoporosis achieved an AUC of 0.983, 0.940 and 0.978. The Delong test showed that there was no significant difference in area under the curve (AUC) values between the osteopenia group and osteoporosis group (P = 0.210, 0.546), while the AUC value of normal model 2 was higher than that of model 1 (0.990 vs. 0.983, P = 0.033). CONCLUSION: This study proposed a chest CT deep learning model that achieves favorable performance on opportunistic osteoporosis screening using the lumbar 1 + lumbar 2 vertebral bodies fusion feature images. We further constructed the comparable model based on the lumbar 1 vertebra alone which can shorten the scan length, reduce the radiation dose received by patients, and reduce the training cost of technologists.


Asunto(s)
Enfermedades Óseas Metabólicas , Osteoporosis , Humanos , Densidad Ósea , Estudios Retrospectivos , Absorciometría de Fotón/métodos , Osteoporosis/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
17.
Intern Med ; 63(16): 2269-2275, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38171859

RESUMEN

Objective Bronchoscopic lung volume reduction (BLVR) using a one-way endobronchial valve (EBV) can provide clinically meaningful benefits to chronic obstructive pulmonary disease (COPD) patients. Although the Japanese Pharmaceuticals and Medical Devices Agency approved EBVs in November 2022, information regarding the number of Japanese patients with severe COPD eligible for BLVR treatment is still lacking. We therefore screened computed tomography (CT) images of patients with severe COPD using a quantitative CT (QCT) analysis to estimate the proportion of candidates eligible for BLVR treatment with an EBV. Methods CT scans of COPD patients with Global Initiative for Chronic Obstructive Lung Disease (GOLD) stages 3 and 4 were retrospectively analyzed using QCT to evaluate fissure integrity and tissue destruction. The difference in volume-weighted percentage was measured using the density scores of the target lobe and ipsilateral non-target lobe at -910 Hounsfield units. The target lobe was defined as the most affected lobe, with an emphysema destruction score of >50% for each patient. Results High-resolution CT scans of 32 patients (GOLD 3=19, GOLD 4=13) were analyzed. The target lobe could not be identified in 1 patient, whereas the target lobes for 8 patients were not surrounded by fissures with ≥80% completeness. Conversely, in 13 patients, the target lobes were surrounded by fissures with >95% completeness. The remaining 10 patients had fissure completeness between 80% and 95% at the target lobes and were considered candidates for collateral ventilation assessment. Conclusion A QCT analysis showed that 23 of 32 patients with severe COPD could be considered for a thorough examination of BLVR treatment with EBV.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Enfisema Pulmonar , Tomografía Computarizada por Rayos X , Humanos , Masculino , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Femenino , Anciano , Estudios Retrospectivos , Enfisema Pulmonar/diagnóstico por imagen , Japón , Persona de Mediana Edad , Neumonectomía , Índice de Severidad de la Enfermedad , Broncoscopía/métodos , Anciano de 80 o más Años , Pulmón/diagnóstico por imagen , Pulmón/patología , Pueblos del Este de Asia
18.
Acad Radiol ; 31(4): 1676-1685, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37758587

RESUMEN

RATIONALE AND OBJECTIVES: Idiopathic Pulmonary Fibrosis (IPF) is a progressive interstitial lung disease characterised by heterogeneously distributed fibrotic lesions. The inter- and intra-patient heterogeneity of the disease has meant that useful biomarkers of severity and progression have been elusive. Previous quantitative computed tomography (CT) based studies have focussed on characterising the pathological tissue. However, we hypothesised that the remaining lung tissue, which appears radiologically normal, may show important differences from controls in tissue characteristics. MATERIALS AND METHODS: Quantitative metrics were derived from CT scans in IPF patients (N = 20) and healthy controls with a similar age (N = 59). An automated quantitative software (CALIPER, Computer-Aided Lung Informatics for Pathology Evaluation and Rating) was used to classify tissue as normal-appearing, fibrosis, or low attenuation area. Densitometry metrics were calculated for all lung tissue and for only the normal-appearing tissue. Heterogeneity of lung tissue density was quantified as coefficient of variation and by quadtree. Associations between measured lung function and quantitative metrics were assessed and compared between the two cohorts. RESULTS: All metrics were significantly different between controls and IPF (p < 0.05), including when only the normal tissue was evaluated (p < 0.04). Density in the normal tissue was 14% higher in the IPF participants than controls (p < 0.001). The normal-appearing tissue in IPF had heterogeneity metrics that exhibited significant positive relationships with the percent predicted diffusion capacity for carbon monoxide. CONCLUSION: We provide quantitative assessment of IPF lung tissue characteristics compared to a healthy control group of similar age. Tissue that appears visually normal in IPF exhibits subtle but quantifiable differences that are associated with lung function and gas exchange.


Asunto(s)
Fibrosis Pulmonar Idiopática , Enfermedades Pulmonares Intersticiales , Humanos , Fibrosis Pulmonar Idiopática/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Pulmón/patología , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Biomarcadores , Estudios Retrospectivos
19.
J Endocrinol Invest ; 47(4): 843-856, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37872466

RESUMEN

PURPOSE: Despite the potentially destructive effect of sympathetic activity on bone metabolism, its impact on bone microarchitecture, a key determinant of bone quality, has not been thoroughly investigated. This study aims to evaluate the impact of sympathetic activity on bone microarchitecture and bone strength in patients with pheochromocytoma and paraganglioma (PPGL). METHODS: A cross-sectional study was conducted in 38 PPGL patients (15 males and 23 females). Bone turnover markers serum procollagen type 1 N-terminal propeptide (P1NP) and ß-carboxy-terminal crosslinked telopeptide of type 1 collagen (ß-CTX) were measured. 24-h urinary adrenaline (24hUE) and 24-h urinary norepinephrine levels (24hUNE) were measured to indicate sympathetic activity. High-resolution peripheral quantitative computed tomography (HR-pQCT) was conducted to evaluate bone microarchitecture in PPGL patients and 76 age-, sex-matched healthy controls (30 males and 46 females). Areal bone mineral density (aBMD) was measured by dual-energy X-ray absorptiometry (DXA) simultaneously. RESULTS: PPGL patients had a higher level of ß-CTX. HR-pQCT assessment revealed that PPGL patients had notably thinner and more sparse trabecular bone (decreased trabecular number and thickness with increased trabecular separation), significantly decreased volume BMD (vBMD), and bone strength at both the radius and tibia compared with healthy controls. The deterioration of Tt.vBMD, Tb.Sp, and Tb.1/N.SD was more pronounced in postmenopausal patients compared with the premenopausal subjects. Moreover, subjects in the highest 24hUNE quartile (Q4) showed markedly lower Tb.N and higher Tb.Sp and Tb.1/N.SD at the tibia than those in the lowest quartile (Q1). Age-related bone loss was also exacerbated in PPGL patients to a certain extent. CONCLUSIONS: PPGL patients had significantly deteriorated bone microarchitecture and strength, especially in the trabecular bone, with an increased bone resorption rate. Our findings provide clinical evidence that sympathetic overstimulation may serve as a secondary cause of osteoporosis, especially in subjects with increased sympathetic activity.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Osteoporosis , Paraganglioma , Feocromocitoma , Masculino , Femenino , Humanos , Estudios Transversales , Huesos , Densidad Ósea/fisiología , Absorciometría de Fotón
20.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1019079

RESUMEN

Objective To investigate the correlation between bone mineral density(BMD)at different hip positions with muscle parameters and physical performance in middle-aged and elderly people in Kunming area.Methods 531 middle-aged and elderly volunteers were recruited from the Radiology Department of the First People's Hospital of Yunnan Province from May 2021 to April 2022.All study subjects completed the five-times-sit-to-stand test(FTSST)and hip quantitative CT(QCT)examinations.Volunteers'total hip(TH),femoral neck(FN),and intertrochanteric(IT)BMD were measured by using QCT PRO workstation and using OsiriX software to measure the area and density of their gluteus maximus muscle,gluteus medius,and minimus muscle and midthigh muscle.Divide male and female volunteers into positive and negative groups respectively based on FTSST time≥12 seconds or<12 seconds,and analyze the differences in hip BMD between the groups;Also divide male and female volunteers into three groups(50~59 years old,60~69 years old,70 years old and above)at the age of 10,and analyze the correlation between hip BMD and muscle parameters in different age and gender stratification.Control for age and BMI,and then perform partial correlation analysis on the above indicators.Results The BMD of the hip in the female FTSST positive group was lower than that in the negative group(P<0.001),while there was no statistically significant difference between the male groups(P>0.05).After adjusting for age and BMI,among males,FN BMD was positively correlated with gluteus medius and minimus muscle density in the age groups of 50~59 and 60~69(P<0.05),while TH BMD,FN BMD,and IT BMD were strongly positively correlated with gluteus medius and minimus muscle density in the age group over 70(P<0.05).For females,the correlation between hip BMD and muscle density in the age groups of 50~59 and 60~69 was weak,while BMD in all parts of the hip was not correlated with muscle density in the age group over 70(P>0.05).There was a negative correlation between TH BMD,FN BMD,and gluteus medius and minimus muscle area in the age group of 50~59 years old for males(P<0.05),while there was a significant negative correlation between TH BMD,IT BMD,and gluteus maximus area in the age group of 70 years old and above for females(P<0.05).Conclusion The BMD of various parts of the hip in the female FTSST positive group is lower than that in the negative group.The density of the gluteus medius and minimus muscle can to some extent serve as a predictive indicator of femoral neck bone strength in middle-aged and elderly men in Kunming area.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA