Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Arthroplasty ; 35(11): 3230-3236.e3, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32665157

RESUMEN

BACKGROUND: The purpose of this study is to determine if there is a difference in echocardiographic results between patients with metal-on-metal (MoM) vs non-MoM total hip arthroplasty (THA) and to determine if a correlation exists between serum metal levels and echocardiographic outcomes. METHODS: Seventy-five patients with the same modular THA enrolled in this prospective cohort study, and 49 had MoM bearings. All patients had serum cobalt, chromium, and titanium levels drawn at 2 study visits with a transthoracic echocardiogram at the second visit. Serum metal concentrations and echocardiographic parameters were compared with 2-way t-tests. Multiple linear regression analyses identified any significant predictors of echocardiographic outcomes. RESULTS: Mean serum cobalt and chromium levels were significantly greater in the MoM group at both time-points (P < .001 and P < .05, respectively). Titanium levels were similar between groups (P > .05). MoM patients had significantly lower global longitudinal strain compared with the non-MoM group (18.4% vs 20.2%; P = .026). Serum cobalt concentration was found to be an independent predictor of tricuspid annular plane systolic excursion (P = .02). CONCLUSION: MoM THA bearings are associated with increased serum cobalt and chromium levels. Patients with MoM THAs had decreased global longitudinal strain, a measure of left ventricular function, but both groups remained within normal range. The clinical impact of the positive association between serum cobalt concentration and tricuspid annular plane systolic excursion, a marker of right ventricular function, deserves further study. These findings can reassure physicians and patients that metal-induced cardiomyopathy is not typical in the setting of MoM THA. LEVEL OF EVIDENCE: Level II, Prospective Cohort Study.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Artroplastia de Reemplazo de Cadera/efectos adversos , Cromo , Cobalto/efectos adversos , Ecocardiografía , Prótesis de Cadera/efectos adversos , Humanos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Estudios Prospectivos , Diseño de Prótesis
2.
Eur J Orthop Surg Traumatol ; 29(3): 717-723, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30317469

RESUMEN

The authors report on a case of modular femoral neck fracture which appeared 21 months after revision of acetabular component. The revision surgery was performed 8 years after the primary total hip arthroplasty due to aseptic loosening of the acetabular component. During acetabular revision, the primary implanted short (S, - 3.5 mm) femoral head was also exchanged with extra-long (XL, + 7.0 mm) femoral head fitting the modular femoral neck with a longer lever arm. Numerical analysis has shown that this has resulted in a 19.9% increase in tensile stress at the neck-stem coupling during normal walking cycle. This could result in microcrack initiation and propagation and finally lead to modular neck failure of the otherwise well-fixed stem. Surgeons should avoid excessive loading of the exchangeable neck (dual-modular) femoral stem designs as the stem-neck couplings are subject to corrosion and are not as reliable as monoblock stems.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera/efectos adversos , Falla de Prótesis/etiología , Reoperación/instrumentación , Estrés Mecánico , Análisis de Elementos Finitos , Humanos , Masculino , Persona de Mediana Edad
3.
Skeletal Radiol ; 46(5): 641-649, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28204856

RESUMEN

OBJECTIVE: The use of metal-on-metal and modular total hip arthroplasty is associated with potentially serious local and systemic complications. The primary aim of this study was to identify the prevalence of a pseudotumor in asymptomatic patients with a particular metal-on-metal hip prosthesis after a minimum follow-up of 5 years using ultrasound evaluation. A secondary purpose was to identify associations between the presence of pseudotumor and serum metal ion levels following implantation. METHODS: We prospectively evaluated data collected from 36 asymptomatic patients who underwent implantation of a Profemur Z metal-on-metal total hip arthroplasty from January 2004 to January 2010. Serum metal ion levels were collected in 2012 and 2015. Hip ultrasounds were performed in 2015. RESULTS: Pseudotumors were found in 7/36 patients (19.4%). The average pseudotumor size measured 38.2 cm3 (range 7.35 cm3-130.81 cm3). Elevated metal ion levels were found in all patients at all time points. No statistical correlation was found between the presence of pseudotumor and patient age, age of the implant, component design, and any of the serum metal ion levels or ratios. CONCLUSIONS: One in every five asymptomatic patients with metal-on-metal implants was found to have a periarticular pseudotumor. There was no dose-dependent relationship found between elevated serum metal ion levels and the development of a pseudotumor. Our findings suggest that in patients with known elevated metal ion levels, continued monitoring of ion levels may not be a reliable predictor of pseudotumor formation, and ultrasound surveillance can and should be routinely used to document the presence and progression of pseudotumor.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Granuloma de Células Plasmáticas/diagnóstico por imagen , Articulación de la Cadera/diagnóstico por imagen , Prótesis Articulares de Metal sobre Metal/efectos adversos , Metales/sangre , Ultrasonografía/métodos , Anciano , Femenino , Estudios de Seguimiento , Granuloma de Células Plasmáticas/sangre , Articulación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Prospectivos