Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Korean J Orthod ; 54(5): 316-324, 2024 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-39175205

RESUMEN

Objective: To evaluate tooth displacement and periodontal stress generated by the dual action vertical intra-arch technique (DAVIT) for open-bite correction using three-dimensional finite element analysis. Methods: A three-dimensional model of the maxilla was created by modeling the cortical bone, cancellous bone, periodontal ligament, and teeth from the second molar to the central incisor of a hemiarch. All orthodontic devices were designed using specific software to reproduce their morpho-dimensional characteristics, and their physical properties were determined using Young's modulus and Poisson's coefficient of each material. A linear static simulation was performed to analyze the tooth displacements (mm) and maximum stresses (Mpa) induced in the periodontal ligament by the posterior intrusion and anterior extrusion forces generated by the DAVIT. Results: The first and second molars showed the greatest intrusion, whereas the canines and lateral incisors showed the greatest extrusion displacement. A neutral zone of displacement corresponding to the fulcrum of occlusal plane rotation was observed in the premolar region. Buccal tipping of the molars and lingual tipping of the anterior teeth occurred with intrusion and extrusion, respectively. Posterior intrusion generated compressive stress at the apex of the buccal roots and furcation of the molars, while anterior extrusion generated tensile stress at the apex and apical third of the palatal root surface of the incisors and canines. Conclusions: DAVIT mechanics produced a set of beneficial effects for open-bite correction, including molar intrusion, extrusion and palatal tipping of the anterior teeth, and occlusal plane rotation with posterior teeth uprighting.

2.
Dental press j. orthod. (Impr.) ; 28(2): e2321345, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1439988

RESUMEN

ABSTRACT Objectives: This clinical trial was conducted to evaluate the stability and failure rate of surface-treated orthodontic mini-implants and determine whether they differ from those of non-surface-treated orthodontic mini-implants. Trial Design: Randomized clinical trial with a split-mouth study design. Setting: Department of Orthodontics, SRM Dental College, Chennai. Participants: Patients who required orthodontic mini-implants for anterior retraction in both arches. Methods: Self-drilling, tapered, titanium orthodontic mini-implants with and without surface treatment were placed in each patient following a split-mouth design. The maximum insertion and removal torques were measured for each implant using a digital torque driver. The failure rates were calculated for each type of mini-implant. Results: The mean maximum insertion torque was 17.9 ± 5.6 Ncm for surface-treated mini-implants and 16.4 ± 9.0 Ncm for non-surface-treated mini-implants. The mean maximum removal torque was 8.1 ± 2.9 Ncm for surface-treated mini-implants and 3.3 ± 1.9 Ncm for non-surface-treated mini-implants. Among the failed implants, 71.4% were non-surface-treated mini-implants and 28.6% were surface-treated mini-implants. Conclusion: The insertion torque and failure rate did not differ significantly between the groups, whereas the removal torque was significantly higher in the surface-treated group. Thus, surface treatment using sandblasting and acid etching may improve the secondary stability of self-drilling orthodontic mini-implants. Trial registration: The trial was registered in the Clinical Trials Registry, India (ICMR NIMS). Registration number: CTRI/2019/10/021718


RESUMO Objetivos: Este ensaio clínico foi conduzido para avaliar a estabilidade e a taxa de falha de mini-implantes ortodônticos com superfície tratada, e determinar se elas diferem das dos mini-implantes ortodônticos sem superfície tratada. Desenho do estudo: Ensaio clínico randomizado com desenho de boca dividida. Instituição: Department of Orthodontics, SRM Dental College, Chennai/India. Participantes: Pacientes que necessitavam de mini-implantes ortodônticos para retração anterior em ambas as arcadas. Métodos: Mini-implantes ortodônticos autoperfurantes, cônicos, de titânio com ou sem tratamento de superfície, foram colocados em cada paciente, seguindo um desenho de boca dividida. Os torques máximos de inserção e de remoção foram medidos para cada mini-implante, usando um torquímetro digital. As taxas de falha foram calculadas para cada tipo de mini-implante. Resultados: O valor médio do torque máximo de inserção foi de 17,9 ± 5,6 Ncm para mini-implantes com superfície tratada e 16,4 ± 9,0 Ncm para mini-implantes sem superfície tratada. O valor médio do torque máximo de remoção foi de 8,1 ± 2,9 Ncm para mini-implantes com superfície tratada e 3,3 ± 1,9 Ncm para mini-implantes sem superfície tratada. Entre os implantes que falharam, 71,4% eram mini-implantes sem superfície tratada e 28,6% eram mini-implantes com superfície tratada. Conclusão: O torque de inserção e a taxa de falha não diferiram significativamente entre os grupos; porém, o torque de remoção foi significativamente maior no grupo com superfície tratada. Assim, o tratamento de superfície com jateamento e condicionamento ácido pode melhorar a estabilidade secundária dos mini-implantes ortodônticos autoperfurantes. Registro do estudo: Esse estudo foi registrado no Clinical Trials Registry, Índia (ICMR NIMS). Número de registro: CTRI/2019/10/021718

3.
Dental press j. orthod. (Impr.) ; 27(1): e222098, 2022. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1364784

RESUMEN

ABSTRACT Introduction: Orthodontic mini-implants (MI) are a reliable alternative to provide temporary orthodontic anchorage. Prior to miniscrew insertion, the best approach would be to evaluate each possible insertion site and measure the cortical bone thickness, and verify whether it would provide adequate primary stability. Objective: This study aimed to evaluate the difference in cortical bone thickness in areas of mini-implants insertion in patients of different ages, by means of cone beam computed tomography (CBCT). Methods: The sample of this retrospective study was composed of 123 CBCT scans, which were used to measure cortical bone thickness in the buccal and palatal inter-radicular space in the mesial region of the first permanent molars. These measures were compared by using the Student's t-test, ANOVA/Tukey tests, and Linear regression between male and female subjects, from 12 to 30 years old. Results: No significant difference was found in cortical bone thickness between sex, race and sagittal facial patterns. Significantly higher measurement values were observed in patients older than 12 years of age at all sites evaluated. The coefficient β at the adjusted linear regression analysis showed that at each increment in age, mean cortical thickness values increased by 0.06mm in the mandible, 0.03mm in the buccal region and 0.02mm in the palatal region of the maxilla. Conclusions: The increase in cortical bone thickness was positively associated with age; that is, the more advanced the patient's age was, the less chance there was of failure due to primary stability.


RESUMO Introdução: Os mini-implantes ortodônticos (MI) são uma alternativa confiável para fornecer ancoragem esquelética temporária. Antes da inserção do mini-implante, a melhor abordagem seria avaliar cada local de inserção possível, medir a espessura do osso cortical e verificar se proporcionaria uma adequada estabilidade primária. Objetivo: O presente estudo teve como objetivo avaliar a diferença na espessura do osso cortical em áreas de inserção dos mini-implantes em pacientes de diferentes idades, por meio da tomografia computadorizada de feixe cônico. Métodos: A amostra desse estudo retrospectivo foi composta por 123 tomografias computadorizadas de feixe cônico, que foram utilizadas para medir a espessura do osso cortical nos espaços inter-radiculares vestibular e palatino na região mesial dos primeiros molares permanentes. Essas medidas foram comparadas por meio dos testes t de Student, ANOVA/Tukey e regressão linear entre os sexos masculino e feminino, de 12 a 30 anos. Resultados: Não houve diferença estatisticamente significativa na espessura cortical, quando comparados sexo, cor da pele e padrão facial sagital. Foram verificadas medidas significativamente maiores em pacientes com idade superior a 12 anos em todos os sítios avaliados. O coeficiente β da análise de regressão linear ajustada mostrou que, a cada incremento da idade, os valores médios da espessura cortical aumentaram 0,06 mm na mandíbula, 0,03 mm na região vestibular e 0,02 mm na região palatina da maxila. Conclusão: O aumento da espessura do osso cortical teve associação positiva com a idade, ou seja, quanto mais avançada a idade do paciente, menor a chance de falha, devido à estabilidade primária.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Adolescente , Adulto , Adulto Joven , Implantes Dentales , Métodos de Anclaje en Ortodoncia/métodos , Estudios Retrospectivos , Tomografía Computarizada de Haz Cónico/métodos , Hueso Cortical/diagnóstico por imagen , Mandíbula/cirugía , Mandíbula/diagnóstico por imagen , Maxilar/diagnóstico por imagen
4.
Int J Oral Maxillofac Surg ; 48(7): 982-988, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30683542

RESUMEN

The aim of this study was to investigate the association of clinical characteristics and IL4 tag single nucleotide polymorphisms (SNPs; rs2227284 and rs2243268) with orthodontic mini-implant (MI) failure. The sample included 135 subjects of both sexes, mean age 48.7±10years (range 20-76years): 104 in the control group (patients without any MI loss) and 31 in the study group (patients presenting ≥1 MI loss). Genotypes were determined by real-time PCR. Bivariate and multivariate analyses were performed (P<0.05). No association was found between the selected tag SNPs and MI loss. The C allele of the IL4 rs2243268 polymorphism in the recessive model was more frequent in patients who had fewer MIs installed (≤2 vs. >2; P=0.043, odds ratio 0.65, 95% confidence interval 0.58-0.74). On multivariate analysis, smoking habit was significantly associated with the group with multiple MIs installed (P=0.036), however the significance of the association with rs2243268 was not maintained. No association was found between the socio-demographic, smoking, or genetic factors studied and MI loss. This study supports the interaction between host and environmental factors and its influence on susceptibility to orthodontic MI failure.


Asunto(s)
Interleucina-4 , Polimorfismo de Nucleótido Simple , Adulto , Anciano , Alelos , Estudios de Casos y Controles , Femenino , Genotipo , Humanos , Masculino , Persona de Mediana Edad , Fumar , Adulto Joven
5.
Dental press j. orthod. (Impr.) ; 22(5): 90-97, Sept.-Oct. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-891094

RESUMEN

ABSTRACT Objective: To define a map of interradicular spaces where miniscrew can be likely placed at a level covered by attached gingiva, and to assess if a correlation between crowding and availability of space exists. Methods: Panoramic radiographs and digital models of 40 patients were selected according to the inclusion criteria. Interradicular spaces were measured on panoramic radiographs, while tooth size-arch length discrepancy was assessed on digital models. Statistical analysis was performed to evaluate if interradicular spaces are influenced by the presence of crowding. Results: In the mandible, the most convenient sites for miniscrew insertion were in the spaces comprised between second molars and first premolars; in the maxilla, between first molars and second premolars as well as between canines and lateral incisors and between the two central incisors. The interradicular spaces between the maxillary canines and lateral incisors, and between mandibular first and second premolars revealed to be influenced by the presence of dental crowding. Conclusions: The average interradicular sites map hereby proposed can be used as a general guide for miniscrew insertion at the very beginning of orthodontic treatment planning. Then, the clinician should consider the amount of crowding: if this is large, the actual interradicular space in some areas might be significantly different from what reported on average. Individualized radiographs for every patient are still recommended.


RESUMO Objetivo: elaborar um mapa dos espaços inter-radiculares nos quais os mini-implantes podem ser inseridos, em um nível coberto por gengiva inserida; e avaliar se existe correlação entre o apinhamento dentário e a disponibilidade de espaços. Métodos: radiografias panorâmicas e modelos digitais de 40 pacientes foram selecionados seguindo critérios de inclusão. Os espaços inter-radiculares foram medidos nas radiografias panorâmicas, enquanto a discrepância de modelo foi avaliada nos modelos digitais. Realizou-se, então, uma análise estatística para avaliar se os espaços inter-radiculares foram influenciados pela presença do apinhamento dentário. Resultados: na mandíbula, os locais mais adequados para a inserção dos mini-implantes foram os espaços compreendidos entre os segundos molares e primeiros pré-molares; na maxila, entre os primeiros molares e segundos pré-molares, bem como entre caninos e incisivos laterais, e entre os dois incisivos centrais. Os espaços inter-radiculares entre os caninos e incisivos laterais superiores e entre o primeiro e o segundo pré-molares inferiores mostraram-se influenciados pela presença do apinhamento dentário. Conclusões: o mapa dos espaços inter-radiculares mais adequados aqui proposto pode ser adotado como um guia geral para a inserção de mini-implantes, e pode ser usado logo ao início do planejamento do tratamento ortodôntico. Em seguida, o clínico deve levar em consideração a quantidade de apinhamento: caso esse seja grande, o real espaço inter-radicular, em algumas áreas, poderá ser significativamente diferente da média aqui relatada. Assim, recomenda-se que sempre sejam feitas radiografias individualizadas para cada paciente.


Asunto(s)
Humanos , Tornillos Óseos , Implantación Dental Endoósea/métodos , Métodos de Anclaje en Ortodoncia/instrumentación , Maloclusión , Simulación por Computador , Procesamiento de Imagen Asistido por Computador , Radiografía Panorámica , Modelos Dentales
6.
J. res. dent ; 2(2): 169-175, 2014. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: lil-715032

RESUMEN

AIM: The aim of this work was evaluate the insertion and removal torque for orthodontic mini-implants inserted in different inclination. Materials and methods: Ten self[drilling mini-implants from the brand SIN (Sistema de Implantes Nacional, São Paulo/SP, Brazil), and the surgical kit for their insertion were used. Two plaques of synthetic bone of 120mm x 170mm x 41,5mm were used (Sawbones, Pacific Research Laboratories Inc, Vashon, Wash), with 1,5mm height, simulating the cortical bone (density 40 pcf) and 40 mm simulating the medullary bone (density 15 pcf). In each block, five areas were demarcated for each mark, totalizing ten areas. The ten mini-implants were inserted by the same operator, previously calibrated; five of them at 900 and five at 600, using the manual key kit. After the insertion of all the mini-implants, the final threading and the reading of insertion torque value were carried out with a manual torque wrench digital Lutron TQ[8800 (Lutron Electronic Enterprise Co., Ltd, Taipei, Taiwan) until the trans-mucosal profile achieve the cortical bone. The maximum insertion torque value was registered in N/cm. After all the implants inserted, the measurement of removal torque was started, performed in the same way of insertion, but in the opposite anticlockwise. The results were submitted to the T test (parametric) and to a Mann-Whitney test (non-parametric). Results: The results demonstrated that the insertion torque was lower than the removal one in both insertion degrees, with statistically significance. Despite insertion torque at 90 degrees had been lightly higher than that inserted at 60 degrees, they were not statistically significant. Conclusion: In view of the results, it was possible conclude that insertion at 60º angulation does not offer advantages to the primary stability for orthodontic mini-implants.


Asunto(s)
Humanos , Masculino , Femenino , Implantes Dentales , Ortodoncia , Placas Óseas
7.
Araçatuba; s.n; 2011. 54 p. tab, graf.
Tesis en Portugués | BBO - Odontología | ID: biblio-866772

RESUMEN

Objetivo: comparar, por meio do teste de arrancamento, a estabilidade primária de mini-implantes com diâmetro e comprimento diferentes inseridos em osso artificial. Material e método: foram utilizados 80 mini-implantes da marca SIN (Sistema de Implante) com 1mm de perfil transmucoso e divididos em 4 grupos: grupo I - mini-implantes de 1,4 mm de diâmetro e 6 mm de comprimento ; o grupo II - mini-implantes de 1,4 mm de diâmetro e 8 mm de comprimento; o grupo III - mini-implantes de 1,6 mm de diâmetro e 6 mm de comprimento; grupo IV - mini-implantes de 1,6 mm de diâmetro e 8 mm de comprimento. Os mini-implantes foram inseridos em bloco de osso artificial Sawbones (SAWBONES Pacific Research Laboratories) e submetidos ao teste de arrancamento na máquina de ensaio universal – EMIC. Resultados: os valores médios de força de arrancamento dos mini-implantes oscilaram entre 621.995N a 738.220N. A Análise de Variância mostrou que houve diferença estatisticamente significante entre os grupos (p<0.05). Na comparação entre os grupos houve igualdade entre os grupos I e III. Todas as demais comparações foram estatisticamente diferentes. Conclusões: em relação à estabilidade primária, constatou-se que os grupos I e III foram iguais, enquanto que, todos os demais apresentaram diferença na estabilidade


Objective: to compare, by means of the pullout test, the primary stability of mini-implants with different diameter and length placed in artificial bone. Method: 80 mini-implants Sin (Implant System) with 1mm transmucosal profile and divided into four groups: Group I - mini-implants with diameter of 1.4mm and 6 mm of long; Group II - mini-implants with diameter of 1.4mm and 8 mm long; Group III - mini-implants with diameter of 1.6mm and 6 mm of long; Group IV - mini-implants with a diameter of 1.6mm and 8 mm of long. Mini-implants were inserted in block artificial bone Sawbones (Sawbones Pacific Research Laboratories) and tested in pullout universal testing machine – EMIC. Results: the mean pullout strength of mini-implants ranged from 621.995 to 738,220 N. Analysis of Variance showed that there was a statistically significant difference between the groups (p <0.05). Comparing the groups were only equality between groups I (mini-implants 1.4 Ø x 6 mm) and III (mini-implants Ø 1.6 x 6mm). All other comparisons are statistically different. Conclusions: relative primary stability, it was found that the groups I and III were similar, whereas all others show differences in stability


Asunto(s)
Métodos de Anclaje en Ortodoncia , Ortodoncia , Implantes Dentales
8.
Araçatuba; s.n; 2011. 63 p. ilus, tab.
Tesis en Portugués | LILACS, BBO - Odontología | ID: lil-705169

RESUMEN

Objetivo: avaliar a influência da associação do diâmetro, comprimento e angulação do mini-implante sobre a estabilidade primária a partir da análise do torque de inserção e remoção. Material e método: foram instalados 120 mini-implantes autoperfurantes, cilíndricos, com 1,4 x 6mm, 1,4 x 8mm, 1,6 x 6mm e 1,6 x 8mm, em um bloco de osso artificial. Os mini-implantes foram instalados com o auxílio da chave de mão acoplada ao torquímetro digital, possibilitando a inserção e mensuração do torque com orientação perpendicular e com inclinação de 60° em relação à superfície do bloco de osso artificial. Os mini-implantes foram removidos da mesma forma como inseridos, porém girando-se a chave em sentido anti-horário. Os registros foram realizados através da conexão do torquímetro ao computador e os valores do torque de inserção e remoção foram obtidos pelos picos máximos dos gráficos, registrados pelo software Datalogger e compilados em tabelas. Realizou-se a análise descritiva para obter a média e desvio-padrão de cada grupo, e submeteram-se os resultados à análise de variância (ANOVA). Resultados: a média dos torques variou entre 19,2 a 23,6Ncm nos testes de inserção e entre 11 a 14,66Ncm nos testes de remoção. Conclusões: as variáveis diâmetro e comprimento não exerceram influência significativa nos valores dos torques de inserção e remoção. A angulação de instalação ocasionou aumento significativo desses torques no grupo 7. Os demais grupos, porém, não apresentaram diferença significante entre as angulações.


Objective: evaluate the influence of diameter, length and angulation of mini-implant on the primary stability through the analysis of insertion and removal torque. Material and Methods: were installed 120 self-drilling mini-implants, cylindrical, with 1.4 x 6mm, 1.4 x 8mm, 1.6 x 6mm and 1.6 x 8mm in a block of artificial bone. The screwdriver for mini-implants was connected to digital torquimeter, in order to allow the insertion and measurement of torque oriented perpendicular and slanting at 60° to the bone surface. Mini-implants were removed the using the same procedures, but turning the screw driver counterclockwise. The recordings were made by connecting the torquimeter to the computer and values of insertion and removal torque were obtained by the maximum peak of the graphics, collected by the Datalogger software and compiled into tables. We conducted a descriptive analysis for the mean and standard deviation of each group, and the results submitted to analysis of variance (ANOVA). Results: the mean torques ranged from 19.2 to 23.6Ncm for insertion tests and between 11 to 14.66Ncm for removal tests. Conclusions: the diameter and length did not influence significantly the values of insertion and removal torques. The angle of installation of these torques caused a significant increase in group 7. However, the other groups showed no significant difference between the angles.


Asunto(s)
Métodos de Anclaje en Ortodoncia , Ortodoncia , Torque
9.
Araçatuba; s.n; 2011. 63 p. ilus, tab.
Tesis en Portugués | LILACS, BBO - Odontología | ID: lil-710787

RESUMEN

Objetivo: avaliar a influência da associação do diâmetro, comprimento e angulação do mini-implante sobre a estabilidade primária a partir da análise do torque de inserção e remoção. Material e método: foram instalados 120 mini-implantes autoperfurantes, cilíndricos, com 1,4 x 6mm, 1,4 x 8mm, 1,6 x 6mm e 1,6 x 8mm, em um bloco de osso artificial. Os mini-implantes foram instalados com o auxílio da chave de mão acoplada ao torquímetro digital, possibilitando a inserção e mensuração do torque com orientação perpendicular e com inclinação de 60° em relação à superfície do bloco de osso artificial. Os mini-implantes foram removidos da mesma forma como inseridos, porém girando-se a chave em sentido anti-horário. Os registros foram realizados através da conexão do torquímetro ao computador e os valores do torque de inserção e remoção foram obtidos pelos picos máximos dos gráficos, registrados pelo software Datalogger e compilados em tabelas. Realizou-se a análise descritiva para obter a média e desvio-padrão de cada grupo, e submeteram-se os resultados à análise de variância (ANOVA). Resultados: a média dos torques variou entre 19,2 a 23,6Ncm nos testes de inserção e entre 11 a 14,66Ncm nos testes de remoção. Conclusões: as variáveis diâmetro e comprimento não exerceram influência significativa nos valores dos torques de inserção e remoção. A angulação de instalação ocasionou aumento significativo desses torques no grupo 7. Os demais grupos, porém, não apresentaram diferença significante entre as angulações


Objective: evaluate the influence of diameter, length and angulation of mini-implant on the primary stability through the analysis of insertion and removal torque. Material and Methods: were installed 120 self-drilling mini-implants, cylindrical, with 1.4 x 6mm, 1.4 x 8mm, 1.6 x 6mm and 1.6 x 8mm in a block of artificial bone. The screwdriver for mini-implants was connected to digital torquimeter, in order to allow the insertion and measurement of torque oriented perpendicular and slanting at 60° to the bone surface. Mini-implants were removed the using the same procedures, but turning the screw driver counterclockwise. The recordings were made by connecting the torquimeter to the computer and values of insertion and removal torque were obtained by the maximum peak of the graphics, collected by the Datalogger software and compiled into tables. We conducted a descriptive analysis for the mean and standard deviation of each group, and the results submitted to analysis of variance (ANOVA). Results: the mean torques ranged from 19.2 to 23.6Ncm for insertion tests and between 11 to 14.66Ncm for removal tests. Conclusions: the diameter and length did not influence significantly the values of insertion and removal torques. The angle of installation of these torques caused a significant increase in group 7. However, the other groups showed no significant difference between the angles


Asunto(s)
Métodos de Anclaje en Ortodoncia , Ortodoncia , Torque
10.
Araçatuba; s.n; 2011. 83 p. tab, graf, ilus.
Tesis en Portugués | LILACS, BBO - Odontología | ID: lil-711319

RESUMEN

Os mini-implantes ortodônticos têm comprovado sua eficiência clínica provendo uma ancoragem absoluta, estes dispositivos podem ser instalados sobre pequenos espaços de tecido ósseo, mas devem ser inseridos efetuando uma técnica cirúrgica muito precisa. Devido ao alto índice de contatos radiculares verificado na literatura científica pela utilização clínica dos mini-implantes, surgiu o interesse para estudar mediante tomografia computadorizada, o posicionamento tridimensional de mini-implantes ortodônticos inseridos através de um guia radiográfico-cirúrgico (RAAG). Foram considerados dois grupos neste estudo, o grupo experimental (GE) prospectivo que incluiu um total de 21 pacientes, 14 pacientes do sexo feminino e 7 do sexo masculino, com 18 anos em média. Neste grupo foram inseridos 21 parafusos ortodônticos auto-perfurantes (POAF) com diâmetro de 1.4mm e 8.0mm de comprimento por um mesmo profissional e utilizou-se um guia radiográfico-cirúrgico Ring Accupunture Auricular Guide (RAAG) com diâmetro de 3.0mm. No grupo controle (Gc) retrospectivo foram inseridos 25 (POAF) na maxila sem nenhum tipo de guia radiográfico-cirúrgico, este grupo controle (Gc) incluiu 10 pacientes do sexo feminino e 15 do sexo masculino com 18 anos em média, cada um dos POAF foi instalado por diferentes profissionais. Após a inserção dos POAF todos os 46 pacientes foram submetidos a Tomografia Dental Computadorizada mediante o Tomógrafo ICAT CONE BEAM. Para a comparação entre os grupos de estudados neste ensaio, foram utilizados os testes Kruskall Wallis e “t” de Student. O grupo experimental GE apresentou uma porcentagem de 88% de inserção equidistante de POAF, evidenciando significância estatística em relação ao grupo Gc. O lado direito do grupo experimental GE apresentou melhor posicionamento dos POAF, evidenciando significância estatística em relação ao lado esquerdo do mesmo GE. Os grupos controle Gc1 e Gc2 apresentaram 100% falhas de posicionamento dos POAF, em relação ao centro...


Introduction: Orthodontic Mini-Screws Self Drilling (ODMS) has proven to be effective providing an efficient absolute anchorage. It could be placed in restricted sites, but requiring a precise surgical technique. Recently (ODMS) have become more popular, thus problems has emerged for example; root contact, would lead to perforation or cause other root injuries. However, no systematic study has evaluated the tridimensional position of (ODMS) into the alveolar process, thus in order to diminish iatrogenic root damage a rapid insertion radiographic surgical guide (RAAG) was proposed to place (ODMS) precisely in the interradicular bone. A specific tomography software was used to evaluated the tridimensional position of (ODMS) and its inaccuracy was estimated

Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Tomografía Computarizada de Haz Cónico , Métodos de Anclaje en Ortodoncia , Ortodoncia
11.
Araçatuba; s.n; 2011. 83 p. tab, graf, ilus.
Tesis en Portugués | LILACS, BBO - Odontología | ID: biblio-866807

RESUMEN

Os mini-implantes ortodônticos têm comprovado sua eficiência clínica provendo uma ancoragem absoluta, estes dispositivos podem ser instalados sobre pequenos espaços de tecido ósseo, mas devem ser inseridos efetuando uma técnica cirúrgica muito precisa. Devido ao alto índice de contatos radiculares verificado na literatura científica pela utilização clínica dos mini-implantes, surgiu o interesse para estudar mediante tomografia computadorizada, o posicionamento tridimensional de mini-implantes ortodônticos inseridos através de um guia radiográfico-cirúrgico (RAAG). Foram considerados dois grupos neste estudo, o grupo experimental (GE) prospectivo que incluiu um total de 21 pacientes, 14 pacientes do sexo feminino e 7 do sexo masculino, com 18 anos em média. Neste grupo foram inseridos 21 parafusos ortodônticos auto-perfurantes (POAF) com diâmetro de 1.4mm e 8.0mm de comprimento por um mesmo profissional e utilizou-se um guia radiográfico-cirúrgico Ring Accupunture Auricular Guide (RAAG) com diâmetro de 3.0mm. No grupo controle (Gc) retrospectivo foram inseridos 25 (POAF) na maxila sem nenhum tipo de guia radiográfico-cirúrgico, este grupo controle (Gc) incluiu 10 pacientes do sexo feminino e 15 do sexo masculino com 18 anos em média, cada um dos POAF foi instalado por diferentes profissionais. Após a inserção dos POAF todos os 46 pacientes foram submetidos a Tomografia Dental Computadorizada mediante o Tomógrafo ICAT CONE BEAM. Para a comparação entre os grupos de estudados neste ensaio, foram utilizados os testes Kruskall Wallis e “t” de Student. O grupo experimental GE apresentou uma porcentagem de 88% de inserção equidistante de POAF, evidenciando significância estatística em relação ao grupo Gc. O lado direito do grupo experimental GE apresentou melhor posicionamento dos POAF, evidenciando significância estatística em relação ao lado esquerdo do mesmo GE. Os grupos controle Gc1 e Gc2 apresentaram 100% falhas de posicionamento dos POAF, em relação ao centro...


Introduction: Orthodontic Mini-Screws Self Drilling (ODMS) has proven to be effective providing an efficient absolute anchorage. It could be placed in restricted sites, but requiring a precise surgical technique. Recently (ODMS) have become more popular, thus problems has emerged for example; root contact, would lead to perforation or cause other root injuries. However, no systematic study has evaluated the tridimensional position of (ODMS) into the alveolar process, thus in order to diminish iatrogenic root damage a rapid insertion radiographic surgical guide (RAAG) was proposed to place (ODMS) precisely in the interradicular bone. A specific tomography software was used to evaluated the tridimensional position of (ODMS) and its inaccuracy was estimated

Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Tomografía Computarizada de Haz Cónico , Métodos de Anclaje en Ortodoncia , Ortodoncia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA