Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Intervalo de año de publicación
1.
Forensic Sci Int Synerg ; 9: 100484, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39041044

RESUMEN

This study aimed to evaluate the reliability of an age estimation method based on the pulp/tooth area ratio by assessing intra- and inter-examiner agreement across five observers at different intervals. Using the same X-ray device and technical parameters, 96 digital periapical X-ray images of upper and lower canines were obtained from 28 deceased people in Central America, whose age at death ranged from 19 to 49 years. Excellent and good agreement of results were achieved, and there were no statistically significant differences. The R2 value for upper teeth (54.0%) was higher than the R2 value for lower teeth (45.7%). The highest intraclass correlation coefficient value was 0.995 (0.993-0.997) and the lowest 0.798 (0.545-0.895). Inter-examiner agreement was high with values of 0.975 (0.965-0.983) and 0.927 (0.879-0.955). This method is adequate for assessing age in missing and unidentified people, including victims of mass disasters.

2.
São Paulo med. j ; São Paulo med. j;138(4): 310-316, July-Aug. 2020. tab
Artículo en Inglés | LILACS, Sec. Est. Saúde SP | ID: biblio-1139710

RESUMEN

ABSTRACT BACKGROUND: The accuracy of magnetic resonance imaging (MRI) for making the diagnosis of subscapularis tears presents wide variation in the literature and there are few prospective studies. OBJECTIVE: To compare the findings from MRI and arthroscopy for diagnosing subscapularis tears. DESIGN AND SETTING: Diagnostic test study performed in a tertiary care hospital. METHODS: We included patients who underwent arthroscopic rotator cuff repair and who had firstly undergone high magnetic field MRI without contrast. The images were independently evaluated by a shoulder surgeon and two musculoskeletal radiologists. Sensitivity, specificity, positive and negative predictive values, accuracy and inter and intra-observer agreement were calculated. RESULTS: MRIs on 200 shoulders were evaluated. The incidence of subscapularis tears was 69.5% (41.5% partial and 28.0% full-thickness). The inter and intra-observer agreement was moderate for detection of subscapularis tears. The shoulder surgeon presented sensitivity of 51.1% to 59.0% and specificity of 91.7% to 94.4%. The radiologists showed sensitivity of 83.5% to 87.1% and specificity of 41% to 45.9%. Accuracy ranged from 60.5% to 73.0%. CONCLUSION: The 1.5-T MRIs without contrast showed mean sensitivity of 70.2% and mean specificity of 61.9% for detection of subscapularis tears. Sensitivity was higher for the musculoskeletal radiologists, while specificity was higher for the shoulder surgeon. The mean accuracy was 67.6%, i.e. lower than that of rotator cuff tears overall.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Traumatismos de los Tendones/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Artroscopía , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Manguito de los Rotadores/cirugía , Pruebas Diagnósticas de Rutina , Lesiones del Manguito de los Rotadores/cirugía
3.
Bioengineering (Basel) ; 5(3)2018 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-30096868

RESUMEN

Purpose: Evaluation of the performance of a computer-aided diagnosis (CAD) system based on the quantified color distribution in strain elastography imaging to evaluate the malignancy of breast tumors. Methods: The database consisted of 31 malignant and 52 benign lesions. A radiologist who was blinded to the diagnosis performed the visual analysis of the lesions. After six months with no eye contact on the breast images, the same radiologist and other two radiologists manually drew the contour of the lesions in B-mode ultrasound, which was masked in the elastography image. In order to measure the amount of hard tissue in a lesion, we developed a CAD system able to identify the amount of hard tissue, represented by red color, and quantify its predominance in a lesion, allowing classification as soft, intermediate, or hard. The data obtained with the CAD system were compared with the visual analysis. We calculated the sensitivity, specificity, and area under the curve (AUC) for the classification using the CAD system from the manual delineation of the contour by each radiologist. Results: The performance of the CAD system for the most experienced radiologist achieved sensitivity of 70.97%, specificity of 88.46%, and AUC of 0.853. The system presented better performance compared with his visual diagnosis, whose sensitivity, specificity, and AUC were 61.29%, 88.46%, and 0.829, respectively. The system obtained sensitivity, specificity, and AUC of 67.70%, 84.60%, and 0.783, respectively, for images segmented by Radiologist 2, and 51.60%, 92.30%, and 0.771, respectively, for those segmented by the Resident. The intra-class correlation coefficient was 0.748. The inter-observer agreement of the CAD system with the different contours was good in all comparisons. Conclusions: The proposed CAD system can improve the radiologist performance for classifying breast masses, with excellent inter-observer agreement. It could be a promising tool for clinical use.

4.
JBRA Assist Reprod ; 22(3): 228-237, 2018 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-29912521

RESUMEN

OBJECTIVE: Our primary aim was to compare the morphology and morphokinetics on inter- and intra-observer agreement for blastocyst with known implantation outcome. Our secondary aim was to validate the morphokinetic parameters' ability to predict pregnancy using a previous published selection algorithm, and to compare this to standard morphology assessments. METHODS: Two embryologists made independent blinded annotations on two occasions using time-lapse images and morphology evaluations using the Gardner Schoolcraft criteria of 99 blastocysts with known implantation outcome. Inter- and intra-observer agreement was calculated and compared using the two methods. The embryos were grouped based on their morphological score, and on their morphokinetic class using a previous published selection algorithm. The implantation rates for each group was calculated and compared. RESULTS: There was moderate agreement for morphology, with agreement on the same embryo score in 55 of 99 cases. The highest agreement rate was found for expansion grade, followed by trophectoderm and inner cell mass. Correlation with pregnancy was inconclusive. For morphokinetics, almost perfect agreement was found for early and late embryo development events, and strong agreement for day-2 and day-3 events. When applying the selection algorithm, the embryo distributions were uneven, and correlation to pregnancy was inconclusive. CONCLUSIONS: Time-lapse annotation is consistent and accurate, but our external validation of a previously published selection algorithm was unsuccessful.


Asunto(s)
Blastocisto/citología , Implantación del Embrión/fisiología , Desarrollo Embrionario/fisiología , Adulto , Técnicas de Cultivo de Embriones , Transferencia de Embrión/métodos , Femenino , Humanos , Variaciones Dependientes del Observador , Embarazo , Índice de Embarazo , Estudios Retrospectivos , Imagen de Lapso de Tiempo , Adulto Joven
5.
BMC Res Notes ; 10(1): 13, 2017 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-28057045

RESUMEN

BACKGROUND AND AIMS: Between 10 and 20% of all patients undergoing bariatric surgery procedures regain weight secondary to a gastrojejunostomy enlargement. The aim of this study was to validate the interobserver agreement while measuring gastric outlet diameters using a new standard guidewire. METHODS: We selected thirty-five videos of consecutive endoscopic procedures on patients undergoing esophagogastroduodenoscopy after a Roux-en-Y gastric bypass procedure. All videos were evaluated by four raters: two expert endoscopists and two trainees. We excluded videos having a slipped Fobi ring or a strictured gastric outlet. Anastomosis diameter was measured using a novel device with standardized markings on a guidewire (Hydra jagwire, Boston Scientific, Natick. MA) as well as the current gold standard defined as a calibrated endoscopic measuring instrument (Olympus America, Center Valley, PA). RESULTS: We obtained 272 measurements of the gastric outlet. Overall agreement measured through intra-class correlation coefficients for the gold standard was 0.84 (p < 0.01) and 0.83 (p < 0.01) for the new guidewire. Agreement among experts was 0.699 (p < 0.01), while among trainees it was 0.822 (p < 0.01). CONCLUSION: The new guidewire demonstrated a high degree of observer reliability, also presenting similar results between expert endoscopists and trainees.


Asunto(s)
Cirugía Bariátrica/métodos , Endoscopios , Endoscopía/métodos , Estómago/cirugía , Adulto , Anastomosis en-Y de Roux , Calibración , Diseño de Equipo , Femenino , Derivación Gástrica/métodos , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA