1.
Cardiology ; 146(5): 633-640, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34157712

RESUMEN

BACKGROUND: Recent studies using insertable cardiac monitors (ICMs) show a high incidence of atrial fibrillation (AF). Further identifying subsets of patients who could benefit most from ICMs is desirable. We evaluated whether the HAVOC risk score which predicts AF in patients with cryptogenic stroke also predicts AF detection by ICMs in those without recent stroke. METHODS: Participants were included from the prospective, industry-sponsored REVEAL AF study assessing AF incidence in patients with CHADS2 scores ≥3 or =2 with 1 or more additional AF risk factors, who had ICM data and were not receiving anti-arrhythmic drugs. Ischemic stroke occurring less than 1 year prior to enrollment or documented AF were exclusion criteria. AF was defined as an adjudicated ICM-detected episode ≥6 min in duration. HAVOC scores were calculated by assigning 4 points for congestive heart failure, 2 points for each of hypertension, age ≥75 years, valvular disease, and coronary artery disease, and 1 point for each of peripheral vascular disease and obesity (body mass index >30). Scores classified risk as low (0-4), intermediate (5-9), or high (10-14); corresponding AF detection rates were compared using the log-rank test. AF incidence rates in patients with and without a history of remote stroke at baseline were also compared. RESULTS: Among 391 participants, the mean age was 71.5 ± 9.8 years and 186 (47.6%) were women. In total, 130 (33.2%) developed AF over 18 months. Stratification by HAVOC risk score was: 95 (24%) low, 241 (62%) intermediate, and 55 (14%) high. At 18 months, AF incidence in patients with low HAVOC scores (19.5%) was lower than in those with intermediate (32.1%) or high (34.2%) scores. AF incidence was similar among those with (n = 78) versus without (n = 313) remote stroke (27.3% vs. 29.8%; median time from stroke to ICM insertion was 4.2 [2.2-8.2] years). CONCLUSIONS: The HAVOC risk score identified a subset of individuals at greatest risk of developing AF, while AF incidence rates were similar among those with and without remote stroke. The use of the HAVOC score could help identify those at greatest likelihood of manifesting AF during long-term monitoring.


Asunto(s)
Fibrilación Atrial , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Humanos , Persona de Mediana Edad , Estudios Prospectivos
2.
Eur J Med Res ; 25(1): 25, 2020 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-32600384

RESUMEN

BACKGROUND: Detection of atrial fibrillation (AF) after cryptogenic stroke (CS) has therapeutic implications, but the most effective type and optimal duration of monitoring have still to be defined. This study that involved patients with CS or transient ischemic attack (TIA), all of whom carried an implantable cardiac monitor (ICM), sought to assess the incidence of AF and other arrhythmia detected using tele-monitoring or interval-based follow-up by an internal cardiologist at the university medical center of Rostock (UMR) or an external cardiologist. METHODS: The ICM implantation was performed during the inpatient stay in the neurology department, with inclusion and exclusion criteria jointly determined by the neurology and cardiology departments. Cardiologists programmed individual threshold values during ICM implantation, which were designed to instantly trigger an episode being recording and an alarm message being sent out. Outpatient care consisted of tele-monitoring of implants or interval-based follow-up care. RESULTS: The indication for ICM implantation was made for 102 patients, 88 of whom underwent ICM implantation, with full documentation available for these 88 study patients. Within a median observation period of 21.5 months, AF occurred in 19 patients, with a median observation time to the event of 7 months. In all cases, AF detection was followed by immediate medical intervention. Comparing patients with and without AF revealed that the median age of the AF group exceeded by 10 years that of the other patients. Stroke recurrence was recorded in five patients, with a median observation time to the event of 9 months. Comparing patients with and without stroke recurrence revealed that the median age in the stroke recurrence group tended to be higher by 14 years. No statistically significant between-group differences were found with regard to integration into tele-monitoring, nor were there any differences identified between outpatient care at the UMR or in the outpatient sector. CONCLUSIONS: This study confirmed the feasibility of using an interdisciplinary and intersectoral therapeutic approach for monitoring CS patients with implanted ICMs. Further randomized studies are warranted to confirm these encouraging data. An open discussion concerning optimal care forms and opportunities for introducing digitizing care pathways appears warranted.


Asunto(s)
Fibrilación Atrial/diagnóstico , Electrocardiografía Ambulatoria/instrumentación , Accidente Cerebrovascular Isquémico/complicaciones , Monitoreo Fisiológico/instrumentación , Prótesis e Implantes/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos
3.
J Arrhythm ; 33(6): 583-589, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29255505

RESUMEN

Capturing electrocardiograms (ECGs) during spontaneous events is the most powerful available tool to identify or exclude an arrhythmic cause of symptoms, and often can elucidate the definite diagnosis for different conditions, such as transient loss of consciousness (T-LOC), lightheadedness, or palpitations. Current ambulatory ECG monitoring technologies include 24-hour Holter, wearable event recorder, external loop recorder (ELR), and insertable cardiac monitoring (ICM). Of them, Holter ECG is most frequently used in daily practice in Japan, while ELR and ICM are less frequently used. However, the appropriate monitor choice should be based on the expected frequency of symptoms. Frequent events may be adequately detected by Holter ECG, but less frequent symptoms are more effectively assessed by longer-term monitoring (i.e., ELR or ICM). In this report, based on our clinical experience, we review the usefulness of ambulatory ECG monitoring devices, especially of ELR, for evaluating T-LOC and other potentially arrhythmia-related symptoms. Specifically, we focus on the use of ELR and ICM for evaluating Japanese patients with T-LOC.

4.
Pacing Clin Electrophysiol ; 39(3): 216-24, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26643565

RESUMEN

BACKGROUND: An endoscopic transdiaphragmatic epicardial radiofrequency ablation procedure combined with percutaneous endocardial radiofrequency ablation--a hybrid procedure--is a potentially curative treatment option for patients with persistent atrial fibrillation (AF). Long-term effects of arrhythmia elimination on atrial and ventricular remodeling are not completely understood. Therefore, the aim of our study was to quantify echocardiographic structural and functional changes of the left atrium (LA) and left ventricle (LV) following a hybrid procedure. METHODS AND RESULTS: Thirty-seven consecutive patients with symptomatic drug refractory persistent AF underwent a hybrid procedure to achieve complete pulmonary vein and LA posterior wall electrical isolation. AF burden was measured using an insertable electrocardiographic (ECG) monitor. Patients were divided into responders to ablation and nonresponders according to postoperative AF burden at 12-month follow-up (responder < 0.5% vs nonresponder ≥ 0.5%). Median AF burden was 0.32 (0.04-27.5)% for all patients. In responders (19/37 patients), significant echocardiographic reduction of LA volume index from 47 to 41 mL/m(2) (P < 0.05) and improvement of LA function parameters (LA stiffness from 73.3 to 41.3 [P < 0.05], LA emptying fraction from 21% to 45% [P < 0.05], LA global longitudinal strain from 11.2% to 18.8% [P < 0.5]) was documented. In addition, LV systolic function significantly improved in comparison with nonresponders. CONCLUSION: Hybrid ablation of persistent AF achieved stable sinus rhythm in a significant proportion of patients, as evidenced by continuous ECG monitoring, resulting in important LA and LV reverse remodeling after 12 months.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Remodelación Atrial , Ablación por Catéter/métodos , Endoscopía/métodos , Remodelación Ventricular , Enfermedad Crónica , Terapia Combinada/métodos , Ecocardiografía/métodos , Femenino , Atrios Cardíacos/cirugía , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA