Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.670
Filtrar
1.
J Biomed Opt ; 30(Suppl 1): S13704, 2025 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39247519

RESUMEN

Significance: ALA-PpIX and second-window indocyanine green (ICG) have been studied widely for guiding the resection of high-grade gliomas. These agents have different mechanisms of action and uptake characteristics, which can affect their performance as surgical guidance agents. Elucidating these differences in animal models that approach the size and anatomy of the human brain would help guide the use of these agents. Herein, we report on the use of a new pig glioma model and fluorescence cryotomography to evaluate the 3D distributions of both agents throughout the whole brain. Aim: We aim to assess and compare the 3D spatial distributions of ALA-PpIX and second-window ICG in a glioma-bearing pig brain using fluorescence cryotomography. Approach: A glioma was induced in the brain of a transgenic Oncopig via adeno-associated virus delivery of Cre-recombinase plasmids. After tumor induction, the pro-drug 5-ALA and ICG were administered to the animal 3 and 24 h prior to brain harvest, respectively. The harvested brain was imaged using fluorescence cryotomography. The fluorescence distributions of both agents were evaluated in 3D in the whole brain using various spatial distribution and contrast performance metrics. Results: Significant differences in the spatial distributions of both agents were observed. Indocyanine green accumulated within the tumor core, whereas ALA-PpIX appeared more toward the tumor periphery. Both ALA-PpIX and second-window ICG provided elevated tumor-to-background contrast (13 and 23, respectively). Conclusions: This study is the first to demonstrate the use of a new glioma model and large-specimen fluorescence cryotomography to evaluate and compare imaging agent distribution at high resolution in 3D.


Asunto(s)
Neoplasias Encefálicas , Glioma , Imagenología Tridimensional , Verde de Indocianina , Animales , Verde de Indocianina/farmacocinética , Verde de Indocianina/química , Porcinos , Neoplasias Encefálicas/diagnóstico por imagen , Glioma/diagnóstico por imagen , Glioma/patología , Imagenología Tridimensional/métodos , Ácido Aminolevulínico/farmacocinética , Encéfalo/diagnóstico por imagen , Imagen Óptica/métodos , Modelos Animales de Enfermedad
2.
BMC Gastroenterol ; 24(1): 316, 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39289637

RESUMEN

BACKGROUND: During esophagectomy, evaluation of blood supply to the gastric tube is critically important to estimate and avoid anastomotic complications. This retrospective study investigated the relationship between indocyanine green (ICG) fluorescence angiography during esophagectomy and postoperative endoscopy findings, especially mucosal color change. METHODS: This study retrospectively collected data from 86 patients who underwent subtotal esophagectomy and reconstruction using a gastric tube for esophageal cancer at the Tokyo Medical and Dental University between 2017 and 2020. The flow speed of ICG fluorescence in the gastric tube was evaluated during the operation. Additionally, the main root of ICG enhancement and pattern of ICG distribution in the gastric tube were evaluated. On postoperative day 1 (POD1), the change in the mucosal color to white, thought to reflect ischemia, or black, thought to reflect congestion of the proximal gastric tube, was evaluated. The correlations between these factors, clinical parameters, and surgical outcomes were evaluated. Univariate and multivariate analyses used logistic regression to identify the risk factors affecting mucosal color change. RESULTS: Multivariate analyses revealed that the only independent significant predictor of mucosal congestion on POD1 was the ICG enhancement time of the right gastric tube tip (odds ratio, 14.49; 95% confidential interval, 2.41-87.24; P = 0.004). CONCLUSIONS: This study indicated that the ICG enhancement time is related to venous malperfusion and congestion rather than arterial malperfusion and ischemia.


Asunto(s)
Neoplasias Esofágicas , Esofagectomía , Angiografía con Fluoresceína , Verde de Indocianina , Humanos , Esofagectomía/efectos adversos , Esofagectomía/métodos , Masculino , Femenino , Estudios Retrospectivos , Neoplasias Esofágicas/cirugía , Anciano , Persona de Mediana Edad , Angiografía con Fluoresceína/métodos , Colorantes/administración & dosificación , Complicaciones Posoperatorias , Estómago/irrigación sanguínea , Estómago/cirugía , Estómago/diagnóstico por imagen , Flujo Sanguíneo Regional , Anastomosis Quirúrgica/efectos adversos
3.
Int J Surg Case Rep ; 123: 110203, 2024 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-39293222

RESUMEN

INTRODUCTION: Laparoscopic inguinal hernia repair (LIHR) is one of the most common surgical procedures performed worldwide, associated with a roughly 10 % rate of complications, most commonly iatrogenic injury to blood vessels, sometimes necessitating conversion to open surgery. Fluorescence-guided laparoscopic surgery using indocyanine green fluorescence angiography (ICG-FA) facilitates the precise identification of numerous anatomical structures, especially vascular, reducing their risk of iatrogenic injury. We present the first published case and video demonstrating LIHR with ICG-FA to prevent intra-operative vascular injury. PRESENTATION OF CASE: A 46-year-old, otherwise-healthy male with a right inguinal hernia underwent fluorescence-guided LIHR using ICG-FA. Before peritoneal dissection, 2 ml ICG was administered intravenously, followed by 10 ml physiological solution. The surgical field was then illuminated using the Stryker fluorescence system. Once vascular structures were located, the sac was dissected. After reversing the peritoneum, but before placing the extraperitoneal mesh, another dose of ICG was administered intravenously to aid in safely securing the mesh. Both times after ICG injection, both the iliac artery and spermatic arteries were clearly visible throughout their course in the surgical field within 45 s. The hernia was repaired successfully with no complications. DISCUSSION: ICG-FA appears to facilitate inguinal hernia repair by enabling real-time visualization of anatomical structures, theoretically reducing the risk of complications, particularly vascular injuries. It is particularly helpful identifying the inguinal area's highly-vascular 'triangle of doom'. CONCLUSIONS: Further studies are warranted to evaluate short- and the long-term outcomes and cost-effectiveness of ICG-fluorescence angiography during laparoscopic inguinal hernia repair.

4.
Artículo en Inglés | MEDLINE | ID: mdl-39293404

RESUMEN

Background: The most common therapy for gallstones is laparoscopic cholecystectomy (LC). How to help young residents avoid bile duct injuries (BDI) during surgery and grasp LC seems to be a paradox. Methods: We retrospectively reviewed 145 cases of LC operated by two residents under indocyanine green (ICG)-guided mode or normal LC procedures to illustrate the role of ICG mode in boosting the LC learning curve. The clinic data were analyzed by logistic regression, receiver operator curve tests, Cumulative Sum (CUSUM), and Risk-Adjusted Cumulative Sum (RA-CUSUM) analysis. Results: The operation failure rate is similar. However, operation time under ICG mode is shorter than that under normal mode. The peak at the 49th case represented the normal resident's complete mastery of the surgery, while the peak point of ICG mode appeared at the 36th case in the fitting curve. The most significant cumulative risk (peak point) of operation failure of LC was at the 35th case in ICG LC mode, while it appeared in the 49th in normal LC mode. Conclusions: Owing to the advantage of real-time imaging and the stable success rate of cholangiography, ICG-guided LC helps residents shorten the operation time, boost the learning curve, and manage to control the operation failure rate.

5.
Surg Endosc ; 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39294317

RESUMEN

BACKGROUND: Medical devices for fluorescence-guided surgery (FGS) are becoming available at a fast pace. The main challenge for surgeons lies in the lack of in-depth knowledge of optical imaging, different technical specifications and poor standardisation, and the selection of the best device based on clinical application. METHODS: This manuscript aims to provide an up-to-date description of the commercially available fluorescence imaging platforms by comparing their mode of use, required settings, image types, compatible fluorophores, regulatory approval, and cost. We obtained this information by performing a broad literature search on PubMed and by contacting medical companies directly. The data for this review were collected up to November 2023. RESULTS: Thirty-two devices made by 19 medical companies were identified. Ten systems are surgical microscopes, 5 can be used for both open and minimally invasive surgery (MIS), 6 can only be used for open surgery, and 10 only for MIS. One is a fluorescence system available for the Da Vinci robot. Nineteen devices can provide an overlay between fluorescence and white light image. All devices are compatible with Indocyanine Green, the most common fluorescence dye used intraoperatively. There is significant variability in the hardware and software of each device, which resulted in different sensitivity, fluorescence intensity, and image quality. All devices are CE-mark regulated, and 30 were FDA-approved. CONCLUSION: There is a prolific market of devices for FGS and healthcare professionals should have basic knowledge of their technical specifications to use it at best for each clinical indication. Standardisation across devices must be a priority in the field of FGS, and it will enhance external validity for future clinical trials in the field.

7.
J Biomed Opt ; 29(Suppl 3): S33306, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39247899

RESUMEN

Significance: The arterial input function (AIF) plays a crucial role in correcting the time-dependent concentration of the contrast agent within the arterial system, accounting for variations in agent injection parameters (speed, timing, etc.) across patients. Understanding the significance of the AIF can enhance the accuracy of tissue vascular perfusion assessment through indocyanine green-based dynamic contrast-enhanced fluorescence imaging (DCE-FI). Aim: We evaluate the impact of the AIF on perfusion assessment through DCE-FI. Approach: A total of 144 AIFs were acquired from 110 patients using a pulse dye densitometer. Simulation and patient intraoperative imaging were conducted to validate the significance of AIF for perfusion assessment based on kinetic parameters extracted from fluorescence images before and after AIF correction. The kinetic model accuracy was evaluated by assessing the variability of kinetic parameters using individual AIF versus population-based AIF. Results: Individual AIF can reduce the variability in kinetic parameters, and population-based AIF can potentially replace individual AIF for estimating wash-out rate ( k ep ), maximum intensity ( I max ), ingress slope with lower differences compared with those in estimating blood flow, volume transfer constant ( K trans ), and time to peak. Conclusions: Individual AIF can provide the most accurate perfusion assessment compared with assessment without AIF or based on population-based AIF correction.


Asunto(s)
Verde de Indocianina , Imagen Óptica , Humanos , Imagen Óptica/métodos , Verde de Indocianina/química , Verde de Indocianina/farmacocinética , Femenino , Persona de Mediana Edad , Anciano , Masculino , Medios de Contraste/química , Adulto , Arterias/diagnóstico por imagen , Imagen de Perfusión/métodos , Simulación por Computador
8.
Mater Today Bio ; 28: 101200, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39221207

RESUMEN

Triple-negative breast cancer (TNBC) is characterized by higher recurrence rate and mortality. Thermally-mediated ablation via photothermal therapy (PTT) demonstrates considerable promise for the eradication of breast cancer. Nonetheless, the efficacy of PTT is impeded by the thermal tolerance of tumor cells, which is attributed to the augmented expression of heat shock proteins (HSPs). These proteins, which function as ATP-dependent molecular chaperones, confer protection to cancer cells against the cytotoxic heat generated during PTT. Glycolysis is an important way for breast cancer cells to produce ATP, which can promote the occurrence and development of lung metastasis of breast cancer. Therefore, inhibiting glycolysis may diminish the expression of HSPs, curtail the growth of breast cancer, and prevent its metastasis. Glycolytic metabolism plays a pivotal role in the ATP biosynthesis within breast cancer cells, facilitating the progression and dissemination of pulmonary metastases. Consequently, targeting glycolysis presents a strategic approach to HSP expression, the proliferation of breast cancer, and impede its metastatic spread. Herein, we designed an indocyanine green (ICG) and cryptotanshinone (CTS) loaded hyaluronic acid (HA) coated Zeolitic Imidazolate Framework-8 (ZIF-8) drug delivery system. The drug delivery system had excellent photothermal properties, which could reach temperature sufficient for photothermal ablation of tumor cells. (ICG + CTS)@HA-ZIF-8 also showed pH-responsive drug release, enhancing the sustained release of ICG and CTS to extend their systemic circulation duration. Moreover, the HA modification of ZIF-8 served to augment its targeting capabilities both in vitro and in vivo, leveraging the enhanced permeation and retention (EPR) effect, as well as active tumor targeting via the CD44 receptor pathway, resulting in a higher drug concentration and a better therapeutic effect in tumor. (ICG + CTS)@HA-ZIF-8 could downregulate the expression of glycolysis-related protein pyruvate kinase-M2 (PKM2), thereby inhibiting the glycolysis process, further suppressing tumor cell energy metabolism, downregulating the expression of HSPs, overcoming tumor cell heat resistance, and improving PTT effect. It exhibited a notable suppressive impact on both the proliferation and migration of breast cancer cells, potentially offering innovative insights for the visualized PTT in breast cancer treatment.

9.
Mol Pharm ; 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39225111

RESUMEN

Atherosclerosis is a vascular intima condition in which any part of the circulatory system is affected, including the aorta and coronary arteries. Indocyanine green (ICG), a theranostic compound approved by the FDA, has shown promise in the treatment of coronary atherosclerosis after incorporation into nanoplatforms. By integration of ICG with targeting agents such as peptides or antibodies, it is feasible to increase its concentration in damaged arteries, hence increasing atherosclerosis detection. Nanotheranostics offers cutting-edge techniques for the clinical diagnosis and therapy of atherosclerotic plaques. Combining the optical properties of ICG with those of nanocarriers enables the improved imaging of atherosclerotic plaques and targeted therapeutic interventions. Several ICG-based nanotheranostics platforms have been developed such as polymeric nanoparticles, iron oxide nanoparticles, biomimetic systems, liposomes, peptide-based systems, etc. Theranostics for atherosclerosis diagnosis use magnetic resonance imaging (MRI), computed tomography (CT), near-infrared fluorescence (NIRF) imaging, photoacoustic/ultrasound imaging, positron emission tomography (PET), and single photon emission computed tomography (SPECT) imaging techniques. In addition to imaging, there is growing interest in employing ICG to treat atherosclerosis. In this review, we provide a conceptual explanation of ICG-based nanotheranostics for the imaging and therapy of coronary atherosclerosis. Moreover, advancements in imaging modalities such as MRI, CT, PET, SPECT, and ultrasound/photoacoustic have been discussed. Furthermore, we highlight the applications of ICG for coronary atherosclerosis.

10.
Int J Pharm ; 665: 124655, 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39244072

RESUMEN

The efficient elimination of bacteria within the dentinal tubules has been hindered by the poor deposition and short residence of disinfecting agents. Meanwhile, the current irrigant (e.g., NaClO, 5.25 %) shows severe adverse effects on the surrounding soft tissues because of its inherent high irritancy. To address this issue, this work reports an in situ generated sonosensitizer to handle the biofilm in dentinal tubules with minimal adverse effects. The production of nanoscale sonosensitizer involves the concurrent delivery of H2O2 (0.01 %), ferrocene derivative (Fc), and indocyanine green (ICG). With ultrasound treatment, the reaction between H2O2 and Fc liberated Fe3+ that was further complexed with ICG to generate the nanoscale sonosensitizer in situ, followed by singlet oxygen production for potent disinfecting action. Because the above cascade reactions occur within the confined dentinal tubules, the generated ICG-Fe3+ nanosensitizer would show prolonged retention therein. The anti-bacterial potency of nanosensitizer was demonstrated in petrodish and ex vivo biofilm models. Meanwhile, the transmission electron microscope imaging of biofilm and cytotoxicity assay in L929 fibroblast cells proved the superiority of nanosensitizer against NaClO regarding adverse effects. The current work opens new avenues of biofilm elimination in dentinal tubules, showing a high translation potential.

11.
Gynecol Oncol Rep ; 55: 101474, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39252761

RESUMEN

Reducing anastomotic leak rates after bowel resection is a priority among patients undergoing gynecologic oncology surgery. While near-infrared (NIR) angiography has been investigated in the colorectal literature, more recent work has demonstrated promising results when used in gynecologic cancer surgery. It has been repeatedly shown to be a safe intervention that can offer real time assessment of bowel perfusion, offering the surgeon the opportunity to act on the results in the hopes of decreasing the risk of complications.

12.
JPRAS Open ; 41: 389-393, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39252988

RESUMEN

Background: Indocyanine green fluorescence angiography (ICGFA) is gaining popularity as an intraoperative tool to assess flap perfusion. However, it needs interpretation and there is concern regarding a potential for over-debridement with its use. Here we describe an artificial intelligence (AI) method that indicates the extent of flap trimming required. Methods: Operative ICGFA recordings from ten consenting patients undergoing flap reconstruction without subsequent partial/total necrosis as part of an approved prospective study (NCT04220242, Institutional Review Board Ref:1/378/2092), provided the training-testing datasets. Drawing from prior similar experience with ICGFA intestinal perfusion signal analysis, five fluorescence intensity and time-related features were analysed (MATLAB R2024a) from stabilised ICGFA imagery. Machine learning model training (with ten-fold cross-validation application) was grounded on the actual trimming by a consultant plastic surgeon (S.P.) experienced in ICGFA. MATLAB classification learner app was used to identify the most important feature and generate partial dependence plots for interpretability during training. Testing involved post-hoc application to unseen videos blinded to surgeon ICGFA interpretation. Results: Training:testing datasets comprised 7:3 ICGFA videos with 28 and 3 sampled lines respectively. Validation and testing accuracy were 99.9 % and 99.3 % respectively. Maximum fluorescence intensity identified as the most important predictive curve feature. Partial dependence plotting revealed a threshold of 22.1 grayscale units and regions with maximum intensity less then threshold being more likely to be predicted as "excise". Conclusion: The AI method proved discriminative regarding indicating whether to retain or excise peripheral flap portions. Additional prospective patients and expert references are needed to validate generalisability.

13.
SAGE Open Med ; 12: 20503121241269631, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39263633

RESUMEN

Objective: Indocyanine green has been used in the assessment of the gastric conduit perfusion in thoracoscopic esophagectomy to prevent malperfusion-associated anastomotic leak. This study aims to evaluate the initial results of investigating the gastric conduit perfusion with indocyanine green in the surgical treatment of esophageal cancer. Patients and methods: This cross-sectional descriptive study was carried out on 54 esophageal cancer patients undergoing thoracoscopic esophagectomy and gastric conduit reconstruction. The blood flow in the gastric conduit was observed using an infrared camera and indocyanine green after completion of the conduit and after tunneling the conduit through the mediastinum to the neck. Results: The gastric conduit width and length were 5.2 ± 0.3 cm, and 31.5 ± 1.6 cm, respectively. The length of the gastric conduit from the junction between the right and left gastroepiploic to the point where the distal end of the gastric conduit still has a vascular pulse was 11.9 ± 4.3 cm. Seventeen patients (31.5%) had poor blood supply at the distal end of the gastric conduit, with indocyanine green appearance time ⩾ 60 s, in whom anastomotic leaks occurred in five patients (9.3%). The lack of connection between the right and left gastroepiploic vessels was associated with poor blood supply of the distal gastric conduit (p = 0.04). Multivariable logistic regression analysis showed association between the time of indocyanine green appearance at the distal gastric conduit and the risk of anastomotic leak (OR = 1.99, 95% CI = 1.10-3.60, p = 0.02). Conclusion: Investigation of gastric conduit perfusion using indocyanine green in gastric conduit reconstruction detected 31.5% of patients with poor blood supply at the distal end of the conduit, in whom 9.3% had anastomotic leak. The longer indocyanine green appearance time in the distal gastric conduit (segment BC), was associated with the higher rate of the anastomotic leak.

14.
Am J Cancer Res ; 14(8): 3976-3993, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39267659

RESUMEN

Neoadjuvant targeted therapy combining targeted agents with chemotherapy significantly improve survival rates of patients suffering from human epidermal receptor (HER2)-positive breast cancer (BC) in early or locally advanced stages. However, approximately 50% of patients fail to achieve a pathological complete response. In response, targeted photothermal therapy (PTT) and photodynamic therapy (PDT) have emerged as effective strategies to bolster primary tumors treatment. In this context, we developed a novel nanodrug, referred to as "P/ICG", which comprised of a tyrosine-kinase inhibitor pyrotinib and the photosensitizer indocyanine green (ICG). This formulation was created for the targeted and multimodal synergistic therapy of HER2-positive BC. Upon irradiation with near-infrared light, ICG generates high levels of intracellular reactive oxygen species and elevated temperature, enhancing chemotherapy effects of pyrotinib. This synergistic action boosts a highly effective anticancer effect promoting the ferroptosis pathway, providing an efficient therapeutic strategy for treating HER2-positive BC.

15.
Pathol Oncol Res ; 30: 1611853, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39267996

RESUMEN

Accurate lymph node (LN) retrieval during colorectal carcinoma resection is pivotal for precise N-staging and the determination of adjuvant therapy. Current guidelines recommend the examination of at least 12 mesocolic or mesorectal lymph nodes for accurate staging. Traditional histological processing techniques, reliant on visual inspection and palpation, are time-consuming and heavily dependent on the examiner's expertise and availability. Various methods have been documented to enhance LN retrieval from colorectal specimens, including intra-arterial ex vivo methylene blue injection. Recent studies have explored the utility of indocyanine green (ICG) fluorescence imaging for visualizing pericolic lymph nodes and identifying sentinel lymph nodes in colorectal malignancies. This study included 10 patients who underwent colon resection for malignant tumors. During surgery, intravenous ICG dye and an endoscopic camera were employed to assess intestinal perfusion. Post-resection, ex vivo intra-arterial administration of ICG dye was performed on the specimens, followed by routine histological processing and an ICG-assisted lymph node dissection. The objective was to evaluate whether ICG imaging could identify additional lymph nodes compared to routine manual dissection and to assess the clinical relevance of these findings. For each patient, a minimum of 12 lymph nodes (median = 25.5, interquartile range = 12.25, maximum = 33) were examined. ICG imaging facilitated the detection of a median of three additional lymph nodes not identified during routine processing. Metastatic lymph nodes were found in four patients however no additional metastatic nodes were detected with ICG assistance. Our findings suggest that ex vivo intra-arterial administration of indocyanine green dye can augment lymph node dissection, particularly in cases where the number of lymph nodes retrieved is below the recommended threshold of 12.


Asunto(s)
Neoplasias Colorrectales , Estudios de Factibilidad , Verde de Indocianina , Escisión del Ganglio Linfático , Ganglios Linfáticos , Humanos , Verde de Indocianina/administración & dosificación , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/cirugía , Proyectos Piloto , Femenino , Masculino , Anciano , Ganglios Linfáticos/patología , Ganglios Linfáticos/diagnóstico por imagen , Persona de Mediana Edad , Escisión del Ganglio Linfático/métodos , Metástasis Linfática/patología , Metástasis Linfática/diagnóstico por imagen , Colorantes , Fluorescencia , Imagen Óptica/métodos , Anciano de 80 o más Años , Colorantes Fluorescentes/administración & dosificación
16.
J Thorac Dis ; 16(8): 5299-5313, 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39268092

RESUMEN

Background: Thoracoscopic anatomical segmentectomy is increasingly recognized for managing early-stage lung cancer. However accurately identifying intersegmental planes (ISPs), especially in complex lung segments, remains challenging. In comparison to conventional methods, fluorescence imaging represents a novel solution. This study aimed to examine the potential benefits of fluorescence imaging in single-port thoracoscopic anatomical segmentectomy. Methods: A multicenter (three regional hospitals), retrospective, comparative analysis was conducted using data from 402 consecutive patients who underwent single-port thoracoscopic anatomical segmentectomy from June 2020 to December 2022. The cohort included 191 patients treated with the fluorescence method and 211 patients treated with the modified inflation-deflation method. Among the cohort, 130 patients were placed in the simple segmentectomy group and 272 in the complex segmentectomy group. Propensity score matching (PSM) was used to adjust for baseline differences between the fluorescence and modified inflation-deflation subgroups in the complex segmentectomy group. Perioperative outcomes were compared between the groups. Results: In the simple segmentectomy group, no significant differences were observed between the fluorescence and modified inflation-deflation methods regarding segmental resection time, intraoperative blood loss, postoperative chest tube drainage and duration, postoperative pain, length of hospital stay, complication rate, or hospital costs. In the complex segmentectomy group, however, fluorescence imaging significantly shortened segmental resection time (69.37±28.22 vs. 78.80±34.66 min; P=0.03), while reducing intraoperative blood loss (P=0.046); and improving visual analogue scale (VAS) pain scores on the first postoperative day (P=0.006). Both methods demonstrated comparable safety and oncologic effectiveness. Conclusions: Fluorescence-guided single-port thoracoscopic anatomical segmentectomy demonstrated comparable perioperative safety and effectiveness to the modified inflation-deflation technique while offering advantages, such as shorter segmental resection time, for complex segmentectomies.

17.
Updates Surg ; 2024 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-39271640

RESUMEN

To explore the Advantages of Indocyanine Green (ICG) Fluorescence Imaging over Conventional Fiber-Optic Imaging in Laparoscopic Cholangiography and Immediate Suture for Stone Removal. The study is a randomized controlled descriptive research. Consecutive patient data were collected from October 2022 to January 2024 at the Second People's Hospital of Chengdu for those who underwent laparoscopic bile duct exploration and stone removal, totaling 72 cases. According to the order of admission, they were randomly assigned to either the study group or the control group, with 36 cases in each group. Ten minutes preoperatively, indocyanine green (ICG) was administered intravenously through a peripheral vein to the subjects in the study group, to enable real-time fluorescent tracing of the extrahepatic bile ducts during surgery. This study compares the efficiency of bile duct structure and boundary recognition, the timeliness of bile duct incision positioning, operative time, blood loss, and the incidence of bile duct injury between patients who were injected with ICG and those who were not. In addition, it assesses liver function and white blood-cell counts rechecked 24 h postoperatively, the duration of postoperative hospital stay, and the occurrence of bile leakage. The study included 72 patients, with 36 in the indocyanine green (ICG) fluorescence group and 36 in the conventional fiber-optic group, comprising 26 males and 46 females. There were 18 patients with a history of previous biliary exploration surgery and 23 who had undergone previous cholecystectomy. During surgery, ICG fluorescence was successfully visualized in all 36 cases of the ICG group, allowing for a clear view of the anatomical structure and boundaries of the extrahepatic bile ducts. Compared to the control group, the ICG fluorescence group demonstrated a reduction in the time required for identification of the biliary system and positioning of the bile duct incision, as well as a decrease in operative time and postoperative hospital stay; intraoperative blood loss and the incidence of bile leakage were also relatively reduced, with statistically significant differences (P < 0.05). However, there were no statistically significant differences in postoperative serum alanine aminotransferase levels, white blood-cell counts, direct bilirubin, and indirect bilirubin between the two groups (P > 0.05). One case of bile duct injury occurred in the control group. The application of ICG fluorescence navigation in laparoscopic cholecystectomy can effectively enhance the visibility of the bile ducts, rapidly identify the location for bile duct incision, and is conducive to reducing both the duration of surgery and postoperative hospital stay. It also minimizes intraoperative blood loss, prevents bile leakage and bile duct injuries. This program has demonstrating significant clinical value.

18.
Healthcare (Basel) ; 12(17)2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39273776

RESUMEN

This video article summarizes a case study involving the use of pelvic sentinel lymph node (SLN) biopsy for endometrial cancer (EC) staging and treatment utilizing a multi-modal infrared signal technology. This innovative approach combines cervical injection of fluorescent dye indocyanine green (ICG) and near-infrared imaging to enhance SLN detection rates in early-stage EC patients. The study showcases the successful application of advanced technology in improving surgical staging procedures and reducing postoperative morbidity for patients. Multi-modal infrared signal technology consists of different modes of fluorescence imaging used to identify lymph nodes based on near-infrared signals. Each mode serves a specific purpose: overlay image combines white light and near-infrared signals in green, monochromatic visualization shows near-infrared signal in greyscale, and intensity map combines signals in a color scale to differentiate signal intensity. Yellow denotes strong near-infrared signals while blue represents weaker signals. By utilizing a multi-modal approach, surgeons can accurately identify and remove SLN, thus avoiding unnecessary removal of secondary or tertiary echelons.

19.
J Clin Med ; 13(17)2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39274305

RESUMEN

Background: Anastomotic leakage (AL) is one of the most feared complications in colorectal surgery, with an incidence of 12-39% and associated risk of mortality of 2-24%. The causes of AL and the ways to prevent it are currently under investigation. This study aims to verify if a quadruple assessment of colorectal anastomosis could reduce AL incidence. Methods: A retrospective analysis of prospectively collected data on rectal cancer surgery performed from January 2015 to December 2017 and from January 2021 to December 2023 at a tertiary referral cancer centre was performed. Demographics, clinicopathological features, short-term outcomes, recurrences, and survival were investigated. Results: A total of 293 patients were enrolled. AL incidence was lower in the quadruple assessment group than in the control group, reaching a statistically significant result (7.7% vs. 16%; p = 0.001). This result was also confirmed after a propensity score match analysis (PSM), in which the AL rate was lower in the quadruple assessment group (5.4% vs. 12.3%; p = 0.01). Conclusions: This study shows how the systematic implementation of a quadruple assessment when performing a colorectal anastomosis could increase awareness on anastomotic success and reduce the incidence of AL.

20.
J Mech Behav Biomed Mater ; 160: 106739, 2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39276435

RESUMEN

Transcatheter arterial embolization is a minimally invasive intervention process in which the blood supply to a tumor or an abnormal area of tissue is blocked. One of the most commonly used embolic agents in clinics is microsphere (MS). In order to understand the flow behavior of microspheres in arteries, it is essential to study their mechanical properties systematically. In this work, calcium-alginate MSs with varying calcium concentrations were synthesized using a coaxial airflow method. Indocyanine green (ICG) was added as a fluorescent dye. The effect of ICG concentration change on microspheres was investigated by studying morphology, imageability, rheology, and swelling behavior. Then the effect of calcium chloride concentration change on microspheres was studied by conducting rheological tests, atomic force microscopy tests, hemolysis assay, and thrombogenicity assay. Results showed that microspheres with higher ICG concentrations have longer lasting fluorescence and lower storage modulus (G'). Higher concentrations of calcium chloride led to higher G', while the local Young's modulus obtained by AFM test was not significantly affected. The MSs with and without ICG showed good hemocompatibility and thrombogenicity.

SELECCIÓN DE REFERENCIAS